- L-82-562, Interim Deficiency Rept Re Insulation of Conax Support Ring Tongue Connectors.Initially Reported on 821110.Evaluation Could Not Be Completed by 821228.Completion of Testing & Evaluation Anticipated by 830128 + (ML20064F246)
- 05000364/LER-1982-051-03, /03L-0:on 821203,instrumentation Channel Associated W/Feed Flow Indicator FI496 Declared Inoperable When Indicator Failed Low.Caused by Leaking Equalizer Valve. Valve Repaired,Tested & Channel Returned to Svc + (ML20064F248)
- ML20064F249 + (ML20064F249)
- 05000338/LER-1978-113-03, /03l-0 on 780927:after maint,TV-BD100A,B,D & F Were Tested But Not Timed Prior to Return to Svc,Due to Personnel Error.Personnel Have Reviewed the Requirements + (ML20064F253)
- ML20064F260 + (ML20064F260)
- 05000311/LER-1982-148, Forwards LER 82-148/03L-0.Detailed Event Analysis Encl + (ML20064F261)
- 05000395/LER-1982-051, Forwards LER 82-051/03L-0.Detailed Event Analysis Encl + (ML20064F265)
- 05000348/LER-1978-080, Forwards LER 78-080/03L-0, 78-081/03L-0 & 78-038/03X-1 + (ML20064F266)
- 05000335/LER-1982-063, Forwards LER 82-063/01T-0 + (ML20064F270)
- 05000348/LER-1978-080-03, /03L-0 on 781027:while in Mode 1,the Steam Line Pressure Instru Assoc W/Pressure Transmitter PT-484 Failed Low.Caused by Failure of Loop Pwr Supply isolated/non- Isolated(Nlp)Card POY-484 + (ML20064F271)
- 05000348/LER-1978-081-03, /03L-0 on 781102:during Surveillance Test FNP-0- STP-15.0,exterior Door Seals Were Leaking.Caused by Dirty Air Lock Exterior Door Seals.Seals Cleaned & Retested Satisfactorily + (ML20064F274)
- 05000416/LER-1982-151, Forwards LER 82-151/03L-0 + (ML20064F275)
- ML20064F276 + (ML20064F276)
- 05000348/LER-1978-038-03, /03X-1 on 780527:during Unit Startup,B S/G Code Safety Valve Lifted Causing Tavg to Drop Below 541 Degrees F in Violaion of T/S3.1.1.5.Caused by Broken Lower Adjusting Ring Locking Pin.Valve Was Replaced + (ML20064F279)
- 05000395/LER-1982-051-03, /03L-0:on 821202,Sys Test Procedure 145.002 Unsatisfactorily Performed on Waste Evaporator.Caused by Thermal Cut Out Switch Being Disconnected from Evaporator Distillate Pump Junction Box.Switch Replaced + (ML20064F294)
- 05000265/LER-1994-004-03, :on 940131,control Rod Coupling Integrity Neutron Instrumentation Response Test Untimely Completed. Caused by Failure to Prioritize & Track Completion of Qcos 300-4.Procedures Revised + (ML20064F296)
- ML20064F301 + (ML20064F301)
- 05000311/LER-1982-148-03, /03L-0:on 821208,steam Generator 21 Level Channel II Instrument Observed to Have Failed High.Caused by Leakage Past Packing of Instrument Root Valve 21BF23.Valve Repacked & Channel Tested Satisfactorily + (ML20064F302)
- 05000335/LER-1982-063-01, /01T-0:on 821215,during Full Power,Surveillance Revealed That Neither Fire Pump Would Start Automatically Upon Test of Any Four Sys Pressure Switches.Caused by One Firewater Header Pressure Switch in Isolation Mode + (ML20064F305)
- ML20064F312 + (ML20064F312)
- ML20064F321 + (ML20064F321)
- 05000416/LER-1982-151-03, /03L-0:on 821201,smoke Detectors in HPCS Diesel Generator Room & Control Bldg Alarmed & Would Not Reset. Caused by Welding Fumes in Control Bldg.Alarm Deactivated Until Welding Complete + (ML20064F324)
- ML20064F332 + (ML20064F332)
- ML20064F335 + (ML20064F335)
- ML20064F339 + (ML20064F339)
- ML20064F341 + (ML20064F341)
- ML20064F342 + (ML20064F342)
- ML20064F343 + (ML20064F343)
- 05000348/LER-1982-059-03, /03L-0:on 821207,boron Concentration in Boron Injection Tank Was Below Tech Spec Requirements.Caused by Personnel Error.Concentration Returned to Normal Level & Personnel Counseled on Proper Procedures + (ML20064F344)
- ML20064F345 + (ML20064F345)
- 05000296/LER-1982-061, Forwards LER 82-061/03L-0 + (ML20064F350)
- ML20064F367 + (ML20064F367)
- ML20064F379 + (ML20064F379)
- 05000318/LER-1982-054, Forwards LER 82-054/03L-0 + (ML20064F380)
- 05000296/LER-1982-061-03, /03L-0:on 821203,drywell Atmosphere CAM RM 3-90-256 Inoperable Due to Moisture Damaged Particulate Detector.Caused by Accumulation of Condensation in Sample Chamber of CAM Due to Leakage Past O-rings + (ML20064F384)
- PLA-1413, Responds to NRC Re Violations Noted in IE Insp Rept 50-387/82-31.Corrective actions:safety-related Anchors Reworked to Ensure Sufficient Contact to Resist Axial & Torsional Slippage & Detail 600,SPA 600 & Spa 1312 Revised + (ML20064F388)
- ML20064F408 + (ML20064F408)
- ML20064F409 + (ML20064F409)
- ML20064F410 + (ML20064F410)
- ML20064F411 + (ML20064F411)
- ML20064F414 + (ML20064F414)
- PLA-1429, Responds to NRC Re Violations Noted in IE Insp Rept 50-387/82-36.Corrective Actions:Nde Level III Radiographic Film Interpreters re-reviewed 3,000 Radiographs.Six Welds Reworked Successfully + (ML20064F422)
- ML20064F423 + (ML20064F423)
- ML20064F428 + (ML20064F428)
- ML20064F429 + (ML20064F429)
- ML20064F437 + (ML20064F437)
- ML20064F438 + (ML20064F438)
- 05000366/LER-1982-112-02, /02X-3:on 821009,while Operating at 75% Power, Discovered Plant Procedures Did Not Adequately Test Automatic Initiation Logic of Several Plant Sys.Cause Not Stated.New Procedures Written & Performed to Test Logic + (ML20064F439)
- 05000387/LER-1982-064, Forwards LER 82-064/03L-0 + (ML20064F444)
- ML20064F449 + (ML20064F449)
- 05000395/LER-1982-016, Forwards Revised LER 82-016/03L-1.Detailed Event Analysis Encl + (ML20064F453)