Supplemental Response to NRC Re Violations Noted in IE Insp Rept 50-443/82-06.Corrective Actions:Addl NDE Supervisory Personnel Hired & Ekc Type M Film Will Be Utilized to Improve Radiographic Quality
ML20064F414
Person / Time
Site: Seabrook NextEra Energy icon.png
Issue date: 11/22/1982
From: Devincentis J
PUBLIC SERVICE CO. OF NEW HAMPSHIRE, YANKEE ATOMIC ELECTRIC CO.
To: Martin T
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
Shared Package
ML20064F399 List:
References
SBN-380, NUDOCS 8301060338
Download: ML20064F414 (5)


Text

1 j

PUEBLIC SERVICE su a m sTA m 0,'. :i., Office:

Companyof NewHampehere 1671 Worcester Road Framinoham, Monochusetts 01701 l

(617) - 872 8100 November 22, 1982 SBN-380 T.F. B4.2.7 United States Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, PA 19406 Attention:

Mr. T. T. M rtin, Director Division of Engineering and Technical Programs

References:

(a ) Construction Permit CPPR-135 and CPPR-136, Docket Nos. 50-443 and 50-444 (b) USNRC Letter, dated August 24, 1982, " Inspection No.

50-443/82-06," T. T. Martin to W. C. Tallman (c) PSNH Letter, dated September 27, 1982, " Response to Inspection No. 50-443/82-06," W. P. Johnson to T. T. Martin

Subject:

Supplemental Response to Inspection No. 50-443/82-06 Dear Sir We offer the following supplemental response to Inspection 82-06:

A.

On November 9,1982, Mr. H. Kerch, NRC Inspector, made an announced visit to the Seabrook site for the purpose of reviewing the status of the Pullman-Higgins radiography items identified during the NRC CAT Inspection (443/82-06).

Below is a summary of the items discussed and their results:

1.

WELD CS-369-10, F1006 As previously reported, this weld was removed, additional nondestructive examination (NDE) performed, and then cross sectioned. Cross sectioning clearly revealed that the indications on the radiograph were due to slag located near the mid-point in the weld and that there was no incomplete fusion as was indicated by the NRC in Inspection Report 50-443/82-06 [ Reference (b)].

The additional radiographs and the cross-sectioned weld were reviewed by Mr. Kerch.

This item is considered closed.

8301060338 830104 PDR ADOCK 05000443 O

PDR

  • United States Nuclear Regulatory Commission November 22, 1982 Attention:

Mr. T. T. Martin Page 2 2.

WELD Sl-204-02, F0202 NRC radiographic film shows a linear indication which did not appear on the Pullman-Higgins final film. The records show that previous P-H film contained an indication which was repaired and the final film was clear of rejectable indications.

P-H will re-radiograph this weld and make any necessary repairs.

3.

WELD CBS-1202-07 F0708 This weld was interpreted to have an area with a root concavity together with centerline creases. This weld has been further evaluated using ultrasonic inspection in accordance with project positions taken or the evaluation of welds exhibiting a centerline crease condition. No adverse conditions were revealed by this supplemental evaluation.

Mr. Kerch was in agreement with the above discussed evaluation approach being utilized.

B.

Below are some of the generic measures taken, or to be taken, to preclude a repetition of the above identified problems:

1.

A new NDE Level III has been hired to replace reassigned NDE Level III personnel.

2.

The hiring and assigning of additional NDE supervisory personnel.

3.

A program of secondary film review is in the process of being instituted by P-H contingent on acquiring additional qualified personnel.

4.

Utilization of EKC type M film where practical to improve overall radiographic quality.

5.

P-H will perform a random review of 10 percent of previously accepted radiographs of similar weld geometry. It is anticipated this re-review will be completed by March 31, 1982.

Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY d

J. DeVincentis Project Manager ALL/fsf

ASLB SERVICE LIST Philip Ahrens, Esquire Assistant Attorney General Department of the Attorney General Augusta, ME 04333 Representative Beverly Hollingworth Coastal Chamber of Commerce 209 Winnacunnet Road Hampton, NH 03842 William S. Jordan, III, Esquire Harmon & Weiss 1725 I Street, N.W.

Suite 506 Washing ton, DC 20006 E. Tupper Kinder, Esquire Assistant Attorney General Office of the Attorney General 208 State House Annex Concord, NH 03301 Robert A. Backus, Esquire 116 Lowell Street P.O. Box 516 Manchester, NH 03105 Edward J. McDermott, Esquire Sanders and McDermott Professional Association 408 Lafayette Road Hampton, NH 03842

/

Jo Ann Shotwell, Esquire Assistant Attorney General Environmental Protection Bureau L

Department of the Attorney General One Ashburton Place, 19th Floor Boston, MA 02108 l

o

r 2;'

SEABR N S W I M U PUBLIC SERVICE Enginnedng Office:

Companyof New Hampshre 1671 Worcester Road e

Framingham, Mossochusetts 0170)

(617) - 872 - 8100 November 22, 1982 SBN-380 T.F. B4.2.7 United States Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, PA 19406 Attention:

Mr. T. T. Martin, Director Division of Engineering and Technical Programs

References:

(a) Construction Permit CPPR-135 and CPPR-136, Docket Nos. 50-443 and 50-444 (b) USNRC Letter, dated August 24,1982, " Inspection No.

50-443/82-06," T. T. Martin to W. C. Tallman (c) PSNH Letter, dated September 27, 1982, " Response to Inspection No-50-443/82-06," W. P. Johnson to T. T. Martin

Subject:

Supplemental Response to Inspection No. 50-443/82-06 Dear Sir We offer the following supplemental response to Inspection 82-06:

On November 9,1982, Mr. H. Kerch, NRC Inspector, made an announced visit A.

to the Seabrook site for the purpose of reviewing the status of the Pullman-Higgins radiography items identified during the NRC CAT Inspection (443/82-06).

Below is a summary of the items discussed and their results:

1.

WELD CS-369-10, F1006 As previously reported, this weld was removed, additional nondestructive examination (NDE) performed, and then cross sectioned. Cross sectioning clearly revealed that the indications on the radiograph were due to slag located near the mid-point in the weld and that there was no incomplete fusion as was indicated by the NRC in Inspection Report 50-443/82-06 (Reference (b)].

The additional radiographs and the cross-sectioned we were reviewed by Mr. Kerch.

g,, d Q2. f af-This item is considered closed.

P 4

l

. lO

+

tf:

United States Nuclear Regulatory Commission November 22, 1982 Attention:

Mr. T. T. Martin Page 2 L

1 2.

WELD Sl-204-02, F0202 NRC radiographic film shows a linear indication which did not appear f

I on the Pullman-Higgins final film. The records show that previous I[

P-H film contained an indication which was repaired and the final

{

film was clear of rejectable indications.

P-H will re-radiograph this weld and make any necessary repairs.

)

Ck

[

f 3.

WELD CBS-1202-07 F0708 j%

y This weld was interpreted to have an area with a root concavity j

together with centerline creases. This weld has been further j

evaluated using ultrasonic inspection in accordance with project 4

positions taken or the evaluation of welds exhibiting a centerline crease condition. No adverse conditions were revealed by this supplemental evaluation.

i 1

Mr. Kerch was in agreement with the above discussed evaluation approach being utilized.

B.

Below are some of the generic measures taken, or to be taken, to preclude a repetition of the above identified problems:

4 1.

A new NDE Level III has been hired to replace reassigned NDE Level III personnel.

2.

The hiring and assigning of additional NDE supervisory personnel.

3.

A program of secondary film review is in the process of being instituted by P-H contingent on acquiring additional qualified personnel.

4.

Utilization of EKC type M film where practical to improve overall i

radiographic quality.

f i<

5.

P-H will perform a random review of 10 percent of previously accepted radiographs of similar weld geometry. It is anticipated this re-review will be completed by March 31, 1982.

Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY J. DeVincentis Project Manager ALL/fsf

..