- 05000339/LER-1982-055, Forwards LER 82-055/01T-0 + (ML20063L702)
- 2CAN029406, Submits 1993 Annual Primary Coolant Activity Rept.During 1993,no Samples Taken of Primary Coolant Exceeded Limits of TS 3.4.8 + (ML20063L705)
- 05000237/LER-1981-020, Forwards Updated LER 81-020/01X-1 + (ML20063L710)
- ML20063L711 + (ML20063L711)
- ML20063L712 + (ML20063L712)
- 05000339/LER-1982-055-01, /01T-0:on 820827,carbon Lab Analysis Surveillance on Both Trains of Common Safeguards Area Ventilation Sys Expired W/Units in Mode 3.Caused by Lack of Administrative Control.Test Procedure Not Run Every 720-h of Operation + (ML20063L714)
- 0CAN029405, Forwards fitness-for-duty Program Performance Data for Period Jul-Dec 1993,in Accordance w/10CFR26.71(d) + (ML20063L715)
- ML20063L716 + (ML20063L716)
- ML20063L720 + (ML20063L720)
- 05000249/LER-1982-014, Forwards Updated LER 82-014/03X-1 + (ML20063L721)
- ML20063L725 + (ML20063L725)
- ML20063L726 + (ML20063L726)
- 05000237/LER-1981-020-01, During ASME Hydrostatic Test,Water Observed Seeping from Cracks in 2.5-inch Rx Head Spray Line.Caused by Chloride Induced Stress Corrosion Cracking.Cracks Cut Out & Piping Replaced + (ML20063L727)
- 05000370/LER-1994-001-02, :on 940124,discovered TS Surveillance Missed for Inoperable DG 2A Due to Inappropriate Action. Surveillance PT/2/A/4350/25 Initiated & Operations Mgt Procedures Controlling Tagouts Revised + (ML20063L733)
- ML20063L734 + (ML20063L734)
- ML20063L736 + (ML20063L736)
- ML20063L739 + (ML20063L739)
- ML20063L740 + (ML20063L740)
- W3P82-2340, Discusses Discrepancy Between as-built Core Protection Calculator Software & C-E Functional Requirements,Identified in Phase II Test Rept.Current Operation of Calculators Using Present Software Acceptable.Qa Analysis Expected in Sept + (ML20063L741)
- ML20063L742 + (ML20063L742)
- 05000315/LER-1982-069-03, /03L-0:on 820804,fire Seal W-7006 Found to Contain Less than Required Foam Sealant.Caused by Improperly Installed Seal.Repairs Made + (ML20063L743)
- 05000440/LER-1994-002, :on 940128,both Reactor Recirculation Sys Pumps Automatically Downshifted from Fast to Slow Speed.Caused by Equipment Failure.Alarm Cards w/1C34-K618B & Alarm Card in Redundant Trip Sys 1C34-K618A Replaced + (ML20063L748)
- 1CAN039401, Forwards Vols 1-3 to Rev 0 to Twentieth Yr Physical Surveillance of ANO Unit 1 Containment Bldg + (ML20063L749)
- 05000315/LER-1982-070-03, /03L-0:on 820810,during Surveillance Test, Discovered Relay Timer for RHR Pump 1E Would Not Reset Properly.Caused by Misaligned Switch Assembly & Plunger. Assembly & Plunger Realigned & Timer Reinstalled + (ML20063L753)
- ML20063L755 + (ML20063L755)
- 05000325/LER-1982-092, Forwards LER 82-092/03L-0 + (ML20063L764)
- 05000325/LER-1982-092-03, /03L-0:on 820907,discovered That Tech Spec Surveillance Requirement Not Addressed in Control Bldg Carbon Dioxide Fire Extinguishing Sys Operability Test PT-35.Caused by Personnel Oversight.Test Revised + (ML20063L773)
- 05000321/LER-1982-073, Forwards LER 82-073/03L-0 + (ML20063L780)
- ML20063L783 + (ML20063L783)
- ML20063L807 + (ML20063L807)
- 05000325/LER-1982-094, Forwards LER 82-094/03L-0 + (ML20063L810)
- 05000335/LER-1982-036, Forwards LER 82-036/03L-0 + (ML20063L813)
- ML20063L820 + (ML20063L820)
- ML20063L823 + (ML20063L823)
- ML20063L824 + (ML20063L824)
- ML20063L825 + (ML20063L825)
- 05000335/LER-1982-036-03, /03L-0:on 820813,at 99% Power W/Charging Pump B Out of Svc,Charging Pump C Taken Out of Svc to Recharge Discharge Accumulator.Pump Recharged & Restored to Operable Status + (ML20063L827)
- ML20063L841 + (ML20063L841)
- 05000249/LER-1982-012, Forwards Updated LER 82-012/03X-1 + (ML20063L842)
- ML20063L845 + (ML20063L845)
- 05000249/LER-1982-012-03, During Local Leak Testing of Primary Containment Isolation Valves,Drywell & Torus Purge Sys Valve Was Found to Leak at Rate in Violation of Tech Spec Limit.Caused by Failure of Resilient Seating Matl + (ML20063L847)
- ML20063L849 + (ML20063L849)
- ML20063L850 + (ML20063L850)
- IR 05000269/2019006 + (ML20063L851)
- ML20063L854 + (ML20063L854)
- 05000333/LER-1982-034, Forwards LER 82-034/03X-1 + (ML20063L855)
- 05000325/LER-1982-094-03, /03L-0:on 820809,review Revealed Failure of Tech Spec List of Fire Protection Detectors to Reflect Plant Design.Caused by Personnel Failure to Submit Tech Spec Change After Plant Mod Increased Number of Detectors + (ML20063L857)
- ML20063L861 + (ML20063L861)
- 05000333/LER-1982-034-03, /03X-1:on 820713,instrument Flow Components Drift Resulted in Nonconservative Calculation of Core Thermal Power.Rated Thermal Power Limit Exceeded on Approx 75 Days of Cycle 5 Operation.Caused by Instrument Drift + (ML20063L869)
- 05000259/LER-1982-055, Forwards LER 82-055/03L-0 + (ML20063L871)
- 05000369/LER-1993-011, :on 931115,determined That DG 1B Fuel Storage Tank Level Gauge Out of Tolerence Due to Malfuntion of Subj Gauge.Iae Technician Calibrated Level Gauge to Bring Gauge Back Into Tolerence + (ML20063L874)