PUBUC SERVICE SEABROM STATION Engineering Office:

Companyof New Hampshir e 1671 Worcester Road Framinoham. Massachusetts 01701 (617) - 872 - 8100 September 2, 1982 SBN-320 T.F. Q 2.2.2 United States Nuclear Regulatory Commission Region I 631 Park Avenue King of Prussia, PA 19406 Attention:

Mr. Richard W. Starostecki, Director Division of Resident and Project Inspection Re fe re nces :

(a) Construction Permits CPPR-13 5 and CPPR-136, Docket Nos.

50-443 and 50-444 (b) Telecon of August 5,1982, H. E. Wingate (YAEC) to Eugene Kelley (NRC Region I)

Subject:

Interim 10CFR 50.55(e) Report; Sheared Pinion Keys

Dear Sir:

On August 5, 1982, a potentially reportable 10CFR50.55(e) item was re po rted [Re f ere nce (b)] regarding sheared pinion keys in Limitorque Model SB-0-2 5 motor operators.

Previously, on August 4,1982, we were notified by Westinghouse that the discovery of six sheared pinion keys at one site had been reported to the NRC Office of Inspection and Enforcement as a 10CFR Part 21 defect which could potentially ef fect all Westinghouse plants.

The applicability of this item to Seabrook [and thus its reportability or non-reportability under 10 CFR50.55(e)] will be reported to Region I by Oc tobe r 15, 1982.

This report is being filed pursuant to the interim reporting provision of 10CRF50.55(e)(3).

Very truly yours, YANKEE ATOMIC ELECTRIC COMPANY

.)

pk J. DeVincentis Project Manager AL/ces cc: Director, Of fice of Inspection and Enforcement Washington, D. C.

20555 0k&$3 PDR y