- 05000324/LER-1982-097-03, /03L-0:on 820727,review of Time Response Test Procedures for Reactor Water Cleanup Low Level 2 Isolation, Revealed Armature Travel Time for Last Relay in Logic Chain Not Timed.Caused by Improper Terminals.Procedures Revised + (ML20063E129)
- 05000331/LER-1982-038-03, /03L-0:on 820610,suppression Chamber to Drywell Vacuum Breaker Valve CV-4327D Opened & Failed to Close. Caused by Stuck Pneumatic Cylinder in Midposition,Due to Crud Accumulation.New O-rings,seals & Gaskets Installed + (ML20063E131)
- 05000361/LER-1982-066, Forwards LER 82-066/01T-0 & 82-067/01T-0.Detailed Event Analysis Submitted + (ML20063E137)
- ML20063E139 + (ML20063E139)
- ML20063E140 + (ML20063E140)
- 05000361/LER-1982-066-01, /01T-0:on 820719,while in Mode 3,auxiliary Feedwater Sys Train Vendered Inoperable Due to Inability of Valve 2HV4706 to Open Fully.Caused by Bent & Jammed Antirotation Plate/Mechanical Indicator Against Yoke Guides + (ML20063E143)
- ML20063E144 + (ML20063E144)
- 05000321/LER-1982-068, Forwards LER 82-068/03L-0 + (ML20063E151)
- ML20063E155 + (ML20063E155)
- 05000361/LER-1982-067-01, /01T-0:on 820720,while in Mode 3,second Auxiliary Feedwater Sys Train Rendered Inoperable Due to Inability of Valve 2HV4713 to Open Fully.Caused by Loose Coupling Lock Nut Allowing Actuator Shaft to Separate from Valve Stem + (ML20063E157)
- ML20063E161 + (ML20063E161)
- ML20063E163 + (ML20063E163)
- ML20063E164 + (ML20063E164)
- ML20063E165 + (ML20063E165)
- ML20063E167 + (ML20063E167)
- 05000321/LER-1982-068-03, /03L-0:on 820804,reactor Core Isolation Cooling Flow Instrument Switch Failed to Actuate Properly.Caused by Dust & Dirt Accumulation on Switch.Switches Cleaned & Recalibr + (ML20063E168)
- ML20063E169 + (ML20063E169)
- ML20063E172 + (ML20063E172)
- ML20063E173 + (ML20063E173)
- ML20063E179 + (ML20063E179)
- ML20063E184 + (ML20063E184)
- ML20063E187 + (ML20063E187)
- 05000373/LER-1982-037, Forwards LER 82-037/03L-0 + (ML20063E191)
- 05000237/LER-1982-020, Forwards LER 82-020/03L-0.Detailed Event Analysis Encl + (ML20063E200)
- 05000373/LER-1982-037-03, /03L-0:on 820608,Group IV Div 1 Isolation Signal Initiated Unexpectedly.Exhaust Isolation Damper 1VR05YB Failed to Close & Intake Isolation Damper Closed But Failed to Reopen.Caused by Damper Vanes Wedging Against Gasket + (ML20063E206)
- 05000321/LER-1982-064, Forwards LER 82-064/03L-0 + (ML20063E210)
- ML20063E213 + (ML20063E213)
- 05000321/LER-1982-064-03, /03L-0:on 820718,reactor Water Cleanup Sys Primary Containment Outboard Isolation Valve Opened While Sys Inoperable.Caused by Personnel Failure to Clear Outstanding Limiting Condition for Operation Prior to Opening Valve + (ML20063E216)
- 05000249/LER-1981-017, Forwards Updated LER 81-017/03X-1 + (ML20063E218)
- ML20063E221 + (ML20063E221)
- ML20063E225 + (ML20063E225)
- 05000249/LER-1982-024, Forwards LER 82-024/03L-0 + (ML20063E230)
- ML20063E234 + (ML20063E234)
- ML20063E235 + (ML20063E235)
- ML20063E238 + (ML20063E238)
- ML20063E240 + (ML20063E240)
- 05000249/LER-1981-017-03, 3B Motor Generator Set Undervoltage Relay Failed to Trip on Undervoltage Signal. Caused by Sticking Relay Tripping Device.Tripping Device Cleaned,Lubed & Placed Back in Svc + (ML20063E243)
- 0CAN019410, Forwards Rev 17 to Emergency Plan for Ano + (ML20063E244)
- 05000237/LER-1982-020-03, /03L-0:on 820609,approx 200 Gallons Concentrated Waste Found Leaking Onto First Floor of Max Recycle Bldg During Sampling Procedure.Caused by Failed Diaphragm on 1.5-inch Dump Valve AO-2/3-2012-217B + (ML20063E248)
- 05000373/LER-1982-054, Forwards LER 82-054/03L-0 + (ML20063E253)
- ML20063E258 + (ML20063E258)
- ML20063E260 + (ML20063E260)
- 05000373/LER-1982-044, Forwards LER 82-044/03L-0 + (ML20063E261)
- 05000249/LER-1982-024-03, /03L-0:on 820604,during Auto Blowdown Permissive Surveillance Dis 287-1,pressure Switch 155D Would Not Trip. Caused by Leaking Internal Diaphragm.Switch Replaced & Tested + (ML20063E265)
- ML20063E271 + (ML20063E271)
- ML20063E273 + (ML20063E273)
- ML20063E274 + (ML20063E274)
- 05000373/LER-1982-054-03, /03L-0:on 820607,during Source Calibr of Reactor Bldg Ventilation Process Radiation Monitors,Div II Monitor 1D18-N009C Failed to Respond to Source.Caused by Defective Cable Connector.Connector Rebuilt + (ML20063E278)
- ML20063E280 + (ML20063E280)
- ML20063E282 + (ML20063E282)
- ML20063E283 + (ML20063E283)