Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000336/LER-1982-021, Forwards LER 82-021/03L-0 + (ML20055A528)
- 05000295/LER-1982-021-03, /03L-0:on 820620,penetration Pressurization Sys Zone 2 Could Not Be Repressurized to Over 32 Psig.Caused by Sheared Internal Float on Zone in-line Flowmeter,Resulting in Float Falling & Restricting Makeup Flow + (ML20055A530)
- 05000133/LER-1982-004-03, /03L-0:on 820604,during Routine Calibr of Bailey Level Transmitters,Both 18 Ft & 10 Ft Indications Dropped When Ref Legs Were Backfilled.Probably Caused by Evaporation of Ref Legs Since Calibr in 1980 + (ML20055A531)
- 05000336/LER-1982-021-03, /03L-0:on 820604,during Routine Operations,Steam Jet Air Ejector Fire Damper 2-EB-109 Failed Shut.Caused by Failure of Metal Band Required to Hold Damper Open Due to Corrosion.Damper Band,Link & Damper Blades Replaced + (ML20055A532)
- 05000316/LER-1982-051, Forwards LER 82-051/03L-0 + (ML20055A535)
- ML20055A537 + (ML20055A537)
- 05000316/LER-1982-051-03, /03L-0:on 820622,double Resilient Seals on Ring Body Flange & Lock Cover Flange Discovered Not Type B Leak Rate Tested.Caused by Seals Not Being Included in Existing Surveillance Procedure + (ML20055A539)
- ML20055A540 + (ML20055A540)
- IR 05000213/1982012 + (ML20055A541)
- 05000344/LER-1982-010-03, /03L-0:on 820610,following Fuel Removal from Core, Spent Fuel Pool Level Was Inadvertently Pumped Below Min Limit.Caused by Personnel Error.Level Raised by Opening Transfer Canal Door.Level Switch Arm Straightened + (ML20055A542)
- IR 05000298/1981019 + (ML20055A546)
- ML20055A547 + (ML20055A547)
- ML20055A549 + (ML20055A549)
- 0CAN038203, Confirms 820303 Telcon & Updates Status of Util Efforts to Comply w/NUREG-0737,Item II.B.3 Re post-accident Sampling Capability.Problems w/in-line Boron Analysis Equipment Encountered + (ML20055A550)
- ML20055A553 + (ML20055A553)
- ML20055A555 + (ML20055A555)
- ML20055A556 + (ML20055A556)
- IR 05000482/1982004 + (ML20055A557)
- ML20055A559 + (ML20055A559)
- ML20055A560 + (ML20055A560)
- ML20055A561 + (ML20055A561)
- ML20055A562 + (ML20055A562)
- 05000373/LER-1982-042, Forwards LER 82-042/03L-0 + (ML20055A564)
- ML20055A566 + (ML20055A566)
- 05000261/LER-1982-005, Forwards LER 82-005/01T-0 + (ML20055A569)
- 05000373/LER-1982-042-03, /03L-0:on 820611,level 3 Scram & Isolation Occurred Due to Improper Valve Lineup.Caused by Operator Failure to Recognize Potential Drain Path in Lineup for LST-82-250.Meetings W/Staff to Be Held + (ML20055A571)
- 05000261/LER-1982-005-01, /01T-0:on 820628,during Refueling Shutdown,Main Steam Check Valve Discovered in Degraded Condition.Caused by Set Screws Loosened on Valve Disc Tail Pieces.All Three Valves Modified to Correct post-mod Deficiency + (ML20055A572)
- 05000293/LER-1982-017, Forwards LER 82-017/03L-0 + (ML20055A573)
- PM-82-670, Forwards Monthly Operating Repts for June 1982 + (ML20055A575)
- ML20055A577 + (ML20055A577)
- 05000293/LER-1982-017-03, /03L-0:on 820603,indicator Scheme on Vacuum Breaker Did Not Function Properly & Required Test to Prove Drywell to Torus Vacuum Breaker Closure Not Performed. Probably Caused by Faulty Limit Switch + (ML20055A578)
- ML20055A579 + (ML20055A579)
- AECM-82-321, Forwards Descriptions of Actions Planned for Resolving Concerns Raised by J Humphrey.Formal Program Results Will Be Provided by 820819,1001 & 1101 + (ML20055A581)
- ML20055A582 + (ML20055A582)
- 05000315/LER-1982-047, Forwards LER 82-047/03L-0 + (ML20055A583)
- 05000315/LER-1982-047-03, /03L-0:on 820622,discovered That Containment Equipment Hatch Double Resilient Seals on Ring Body Flange Had Not Been Type B Leak Tested Since June 1979.Caused by Testing Not Being Included in Existing Procedures + (ML20055A585)
- ML20055A586 + (ML20055A586)
- 05000361/LER-1982-023, Forwards LER 82-023/03L-0.Detailed Event Analysis Submitted + (ML20055A587)
- 05000361/LER-1982-023-03, /03L-0:on 820608,fire Suppression Water Spray & Sprinkler Sys Initiated by Manual Actuation of Deluge Valve. Cause Not Determined.Alternate Manual Actuators Being Considered + (ML20055A589)
- 05000312/LER-1982-014, Forwards LER 82-014/03L-0.Detailed Event Analysis Submitted + (ML20055A590)
- ML20055A592 + (ML20055A592)
- 05000312/LER-1982-014-03, /03L-0:on 820619,pressurizer Liquid Sample Valve, SFV-70001,opened Properly But Failed to Close Properly on Command.Caused by Ax Relay Not Responding to Close Command. Relay Replaced + (ML20055A593)
- ML20055A594 + (ML20055A594)
- ML20055A595 + (ML20055A595)
- 05000346/LER-1982-028, Forwards LER 82-028/03L-0 + (ML20055A596)
- IR 05000313/1982004 + (ML20055A598)
- 05000346/LER-1982-027, Forwards LER 82-027/03L-0 + (ML20055A601)
- 0CAN048215, Responds to NRC Re Violations Noted in IE Insp Repts 50-313/82-04 & 50-368/82-04.Corrective Actions:Missing Pipe Strap on Line GBD-22 Replaced,Insp of All Seismic Supports Conducted & Manual Valves Mu-23 & 24 Repositioned + (ML20055A603)
- 05000366/LER-1982-059, Forwards LER 82-059/03L-0 + (ML20055A604)
- 05000346/LER-1982-027-03, /03L-0:on 820608,combined Leakage for All Containment Penetration Valves Exceeded Tech Spec Limits. Caused by Component Failure W/Two Valves Failing Due to Misapplication of Seating Matl.Valves Repaired + (ML20055A606)
- 05000249/LER-1982-027, Forwards LER 82-027/01T-0 + (ML20055A607)