Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20054M001 + (ML20054M001)
- ML20054M003 + (ML20054M003)
- 05000338/LER-1982-046, Forwards LER 82-046/03L-0 + (ML20054M004)
- ML20054M006 + (ML20054M006)
- ML20054M007 + (ML20054M007)
- 05000369/LER-1982-044-03, /03L-0:on 820526,HEPA & Carbon Adsorber Filters Periodic Test Revealed That Auxiliary Bldg Ventilation Sys Filters Failed to Pass Total DOP Penetration Test.Caused by Vibration + (ML20054M008)
- ML20054M009 + (ML20054M009)
- 05000320/LER-1982-018, Forwards LER 82-018/03L-0 + (ML20054M011)
- ML20054M013 + (ML20054M013)
- 05000338/LER-1982-046-03, /03L-0:on 820603,control Room Door Seal Failed, Decreasing Emergency Ventilation & Bottled Air Pressurization Sys Ability to Pressurize Control Room. Seal Failure Due to Normal Wear.Seal Replaced + (ML20054M014)
- ML20054M015 + (ML20054M015)
- ML20054M017 + (ML20054M017)
- ML20054M018 + (ML20054M018)
- 05000369/LER-1982-045-03, /03L-0:on 820527,HEPA & Carbon Adsorber Filters Periodic Test Revealed That Carbon Adsorber Filters on Auxiliary Bldg Ventilation Sys Failed to Pass Freon Penetration Test.Caused by Carbon Settlement + (ML20054M020)
- 05000320/LER-1982-018-03, /03L-0:on 820601,air Intake Tunnel Halon Sys Triggered Actuation of Deluge Sys & Tripped Auxiliary & Fuel Handling Bldgs Supply & Exhaust Fans.Caused by Lightning Setting Off Ultraviolet Light Detector.Sys Recharged + (ML20054M021)
- ML20054M022 + (ML20054M022)
- ML20054M023 + (ML20054M023)
- ML20054M025 + (ML20054M025)
- ML20054M027 + (ML20054M027)
- ML20054M028 + (ML20054M028)
- ML20054M029 + (ML20054M029)
- ML20054M030 + (ML20054M030)
- ML20054M031 + (ML20054M031)
- ML20054M032 + (ML20054M032)
- ML20054M034 + (ML20054M034)
- 05000260/LER-1982-018, Forwards LER 82-018/03L-0 + (ML20054M036)
- 05000320/LER-1982-019, Forwards LER 82-019/03L-0 + (ML20054M038)
- ML20054M040 + (ML20054M040)
- ML20054M041 + (ML20054M041)
- 05000280/LER-1982-065-03, /03L-0:on 820609,w/unit at 100% Power,Core Cooling Monitor Channel B Failed,Resulting in Spurious Alarms.Caused by Faulty Thermocouple Input.Input Replaced + (ML20054M044)
- 05000320/LER-1982-019-03, /03L-0:on 820601,wind Speed,Wind Direction & Air Temp Indication in Control Room Lost.Caused by Lightning Striking Meteorological Tower Resulting in Blown Amplifier Chips & Fuse.Components Replaced + (ML20054M045)
- 2CAN068204, Forwards Monthly Operating Rept for May 1982 + (ML20054M046)
- 05000325/LER-1982-061, Forwards LER 82-061/03L-0 + (ML20054M048)
- ML20054M050 + (ML20054M050)
- ML20054M051 + (ML20054M051)
- ML20054M053 + (ML20054M053)
- 05000280/LER-1982-061-03, /03L-0:on 820606,w/unit at 100% Power,Core Cooling Monitor a Showed Erratic Indication & Was Removed from Svc. Caused by Failed Printed Circuit Board.Board Replaced + (ML20054M054)
- 05000260/LER-1982-018-03, /03L-0:on 820602,while Calibr Pressure Switches That Bypass Control Valve Fast Closure/Stop Valve Scram, Pressure Switch PS-1-81B Operated at 156.9 Psig.Caused by Instrument Drift.Switch Recalibr & Tested + (ML20054M055)
- ML20054M056 + (ML20054M056)
- 05000325/LER-1982-061-03, /03L-0:on 820607,source Range Monitor C Indicated Count of 3.0 X 10(4) While Monitors a & D Indicated 1.5 X 10(3).Caused by Failure of Monitor C Input Signal Preamplifier.Preamplifier Replaced + (ML20054M058)
- ML20054M059 + (ML20054M059)
- 05000334/LER-1982-020, Forwards LER 82-020/03L-0 + (ML20054M060)
- 05000334/LER-1981-006, Forwards Updated LER 81-006/03X-1.Detailed Event Analysis Encl + (ML20054M062)
- ML20054M064 + (ML20054M064)
- 05000280/LER-1982-035-03, /03L-0:on 820607,w/unit at Full power,TV-IA-201A Would Not Remain Closed After High Radiation Test Signal Cleared.Caused by Incomplete Valve Contact Due to Loosened Limit Switch Mounting Plate.Plate Secured + (ML20054M065)
- ML20054M066 + (ML20054M066)
- ML20054M068 + (ML20054M068)
- ML20054M069 + (ML20054M069)
- ML20054M070 + (ML20054M070)
- ML20054M071 + (ML20054M071)
- 05000334/LER-1982-020-03, /03L-0:on 820610,chlorine Detector CLA-VS-101B, Found to Have Slow Trip Rate.Caused by Dirty Wick.Wick Checked & Cleaned.Procedure Revised to Replace Demineralized Water W/Distilled Water + (ML20054M072)