ML20054M022

From kanterella
Jump to navigation Jump to search
Fourth Interim Deficiency Rept Re Failure of Stainless Steel Nuts & Bolts to Meet ASTM Specs,Initially Reported 810924. Search Being Conducted to Account for Missing Nuts & Bolts. Also Reportable Per Part 21
ML20054M022
Person / Time
Site: Bellefonte  
Issue date: 06/29/1982
From: Mills L
TENNESSEE VALLEY AUTHORITY
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
REF-PT21-82 10CFR-050.55E, 10CFR-50.55E, NUDOCS 8207090164
Download: ML20054M022 (2)


Text

- - __

TENNESSEE VALLEY AUTHORITY CH A TT A NOOG A. TE MJE'i%EE 3740t 400 Chestnut Street Tower II June 29, 1982 ca rv BLRD-50-438/81-64 BLRD-50-439/81-62 5

.q ja ru 0

U.S. Nuclear Regulatory Comission

,5

.7 5.

Region II

- 2 Attn:

Mr. James P. O'Reilly, Regional Administrator a

101 Marietta Street, Suite 3100 e

Atlanta, Georgia 30303 6

Dear Mr. O'Reilly:

BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 - BOLTS AND NUTS FAIL TO MEET ASTM SPECIFICATIONS - BLRD-50-438/81-64, BLRD-50-439/81 FOURTH INTERIM REPORT The subject deficiency was initially reported to NRC-0IE Inspector R. V. Crlenjak on September 24, 1981 in accordance with 10 CFR 50.55(e) as NCR's 1597 and 1598. This was followed by our interim reports dated October 22 and December 8, 1981 and February 19, 1982. Enclosed is our fourth interim report. We expect to submit our next report by September 28, 1982. We consider 10 CFR Part 21 applicable to this deficiency.

If you have any questions concerning this matter, please get in touch with R. H. Shell at FIS 858-2688.

Very truly yours, TENNESSEE VALLEY AUTHORITY L. M. Mills, Manager Nuclear Licensing Enclosure cc:

Mr. Richard C. DeYoung, Director (Enclosure)

Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 g

bO B207090164 820629 i

PDR ADOCK 05000430 S

PDR

~, e os on

m. m t -#-

.x-ENCLOSURE BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 BOLTS AND NUTS EAIL TO MEET ASTM SPECIFICATIONS NCR'S 1597 AND 1598 BLRD-50-438/81-64, BLRD-50-439/81-62 10 CFR 50.55(e)

FOURTH INTERIM REPORT Description of Deficiency.

10,000, 3/4" stainless steel nuts (furnished by Chattanooga Bolt and Screw, Chattanooga, Tennessee) and 10,600, 3/4" x 3-1/2" stainless steel bolts (furnished by Challenge Enterprises, Chattanooga, Tennessee) were received not marked in accordance with ASTM specifications. Subsequent testing of the subject material by Singleton Materials Engineering Laboratory revealed the material failed to meet ASTM specifications. The associated documentation received with the material erroneously shows that the nuts and bolts do meet ASTM specifications. Approximately 450 of these bolts ana 1300 nuts have been issued to the field for installation.

Nonconformance report (NCR) 1597 pertains to the bolts and NCR 1598 pertains to the nuts.

Interim Progress TVA is continuing its evaluation of the bolts and nuts as specified in the last report. Numerous bolts and nuts cannot be accounted for at this time. However, TVA is continuing its search for them.

Also, test data produced by Singleton Materials Laboratory is being further evaluated by TVA.

1

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _