- ML20040C620 + (ML20040C620)
- ML20040C621 + (ML20040C621)
- ML20040C622 + (ML20040C622)
- ML20040C623 + (ML20040C623)
- ML20040C624 + (ML20040C624)
- ML20040C625 + (ML20040C625)
- ML20040C626 + (ML20040C626)
- ML20040C627 + (ML20040C627)
- 05000324/LER-1981-132, Forwards LER 81-132/03L-0 + (ML20040C628)
- ML20040C630 + (ML20040C630)
- ML20040C631 + (ML20040C631)
- ML20040C633 + (ML20040C633)
- ML20040C634 + (ML20040C634)
- ML20040C635 + (ML20040C635)
- 05000324/LER-1981-132-03, /03L-0:on 811218,reactor Water Cleanup Sys Inboard Primary Containment Isolation valve,2-G31-F001,valve Position Indication Lost & Valve 2-G31-F004 Failed in Open Position.Caused by Short in Valve Closure Circuitry + (ML20040C636)
- 05000259/LER-1981-091, Forwards LER 81-091/03L-0 + (ML20040C637)
- ML20040C639 + (ML20040C639)
- ML20040C641 + (ML20040C641)
- PLA-1001, Final Deficiency Rept Re Failure of American Insulated Wire Corp 600-volt Cable,Originally Reported on 810901.Caused by Gradual Breakdown & Embrittlement of Matl.All Cable Replaced W/Boston Insulated Wire Cable.Also Reported Per Part 21 + (ML20040C642)
- ML20040C643 + (ML20040C643)
- ML20040C644 + (ML20040C644)
- ML20040C645 + (ML20040C645)
- 05000366/LER-1981-134, Forwards LER 81-134/03L-0 + (ML20040C646)
- ML20040C648 + (ML20040C648)
- 05000259/LER-1981-091-03, /03L-0:on 811220,FCO 31-152 Would Not Open During Performance of SI 4.2.G-2,rendering B Control Room Emergency Ventilation Inoperable.Caused by Failure of Modutrol Motor for Fco 31-152 Due to Open Windings.Motor Replaced + (ML20040C649)
- ML20040C652 + (ML20040C652)
- IR 05000244/1981012 + (ML20040C653)
- 05000302/LER-1981-078, Forwards LER 81-078/03L-0.Detailed Analysis Encl + (ML20040C654)
- 05000366/LER-1981-134-03, /03L-0:on 811230,while Operator in Process of Synchronizing Diesel Generator w/4,160-volt G Emergency Bus, Diesel Tripped.Caused by Pressure Fluctuation in Jacket Coolant Subsystem.Affected Pressure Switch Checked + (ML20040C656)
- 05000327/LER-1981-159, Forwards LER 81-159/03L-0 + (ML20040C657)
- ML20040C659 + (ML20040C659)
- ML20040C661 + (ML20040C661)
- ML20040C662 + (ML20040C662)
- 05000219/LER-1981-068-03, /03L-0:on 811218,reactor Triple Low Water Level Indicator Switch RE18A Tripped at Monometer Reading Exceeding Tech Spec Limit.Caused by Instrument Drift.Switch Reset.Setpoint Sensors Will Be Replaced + (ML20040C663)
- 05000302/LER-1981-078-03, /03L-0:on 811208,during Normal Operation,Emergency Feedwater Ultrasonic Flow indicator,FW-313-FI Exceeded Zero Check Low Limit.Caused by Inability of Instrument to Consistently Indicate Zero Flow.Instrument re-zeroed + (ML20040C664)
- 05000327/LER-1981-159-03, /03L-0:on 811221,auxiliary Feedwater Pressure Control Valve 1-PCV-3-132 Failed to Respond During Performance of SI-166.1.Caused by Failure of Hydraulic Pump on Valve Operator to Deliver Discharge Pressure + (ML20040C665)
- ML20040C666 + (ML20040C666)
- 05000338/LER-1981-089, Forwards LER 81-089/03L-0 + (ML20040C667)
- ML20040C671 + (ML20040C671)
- ML20040C672 + (ML20040C672)
- ML20040C673 + (ML20040C673)
- ML20040C674 + (ML20040C674)
- ML20040C675 + (ML20040C675)
- 05000311/LER-1981-131, Forwards LER 81-131/03L-0.Detailed Event Analysis Encl + (ML20040C676)
- ML20040C679 + (ML20040C679)
- 05000338/LER-1981-089-03, /03L-0:on 811217,during 99% Power,Turbine Driven Auxiliary Feedwater Pump Removed from Svc for Insp of Three Upsteam Check Valves.One Valve Found Missing Disc Nut,Washer & Retaining Pin.Parts Replaced on All Three Valves + (ML20040C680)
- 05000335/LER-1981-055, Forwards LER 81-055/03L-0 + (ML20040C681)
- 05000320/LER-1981-037, Forwards LER 81-037/03L-0 + (ML20040C683)
- 05000311/LER-1981-131-03, /03L-0:on 811228,low Reading Noticed on 24 Reactor Coolant Loop Flow Channel 2.Channel Declared Inoperable. Caused by Failure of Flow Transmitter.Flow Transmitter Replaced & Calibr Satisfactorily + (ML20040C685)
- PNO-II-82-012, on 820119,turbine & Reactor Tripped Due to High Water Level in Steam Generator 2 During Automatic Feed Control Sys Adjustment.Feedwater Isolation Resulted in Low Water Level in Steam Generator 1 Actuating Trip + (ML20040C686)