- PNO-II-82-003, on 820108,GE Informed Util of Errors Identified in Power Allocation Factors.Power Distribution & Thermal Limits in Core May Have Exceeded Tech Spec Limits.No Indication of Fuel Degradation Observed + (ML20039F574)
- IR 05000361/1981021 + (ML20039F575)
- ML20039F576 + (ML20039F576)
- ML20039F578 + (ML20039F578)
- 05000324/LER-1981-134, Forwards LER 81-134/03L-0 + (ML20039F579)
- 05000325/LER-1981-089-03, /03L-0:on 811203,suppression Chamber Level Hi/Lo Annunciation Found Sealed in W/Level Exceeding Spec.Caused by Personnel Failure to Detect Level Increase Due to RHR Discharge Check Valve Not Reseating After Pump Operation + (ML20039F581)
- PNO-II-82-002, on 820106,turbine Shut Down Due to Turbine Generator Shaft Vibration.Reactor Being Brought to Cold Shutdown.Plant Will Be Out of Svc for 2 to 2 1/2 Wks for Turbine Balancing,Repairs & Mods + (ML20039F582)
- ML20039F583 + (ML20039F583)
- ML20039F585 + (ML20039F585)
- ML20039F586 + (ML20039F586)
- ML20039F587 + (ML20039F587)
- 05000344/LER-1981-030-03, /03L-0:on 811202,during Review of Plant Problem Rept,Containment Pressure Indicators PI-10075 & PI-10076 Determined Not Reading Gauge Pressure as Indicated.Caused by Improper Design & Installation.Procedural Change Initiated + (ML20039F588)
- TXX-3457, Interim Deficiency Rept Re Eight Underspecified 3/4-inch Auxiliary Feedwater Sys Valves,Initially Reported on 811207. Evaluation Ongoing.Completion Anticipated by 820305 + (ML20039F589)
- ML20039F590 + (ML20039F590)
- 05000324/LER-1981-134-03, /03L-0:on 811207,suppression Chamber Water Temp Recorder on Remote Shutdown Panel Not Recording on Chart. Caused by Worn Solenoid Plunger That Made Print Head Actuation Solenoid Stick.Actuation Solenoid Replaced + (ML20039F591)
- ML20039F592 + (ML20039F592)
- PNO-II-81-114, on 811209,util Advised That News Release Would Be Issued Re Dismissal of Several Guard Force Members for Use of Illegal Drugs,Both Onsite & Offsite.Investigation Began 811204.Plant Security Monitored.Security Adequate + (ML20039F594)
- ML20039F596 + (ML20039F596)
- ML20039F597 + (ML20039F597)
- IR 05000293/1981032 + (ML20039F598)
- 05000324/LER-1981-118, Forwards LER 81-118/03L-0 + (ML20039F599)
- ML20039F601 + (ML20039F601)
- ML20039F603 + (ML20039F603)
- ML20039F605 + (ML20039F605)
- ML20039F607 + (ML20039F607)
- ML20039F608 + (ML20039F608)
- ML20039F609 + (ML20039F609)
- ML20039F611 + (ML20039F611)
- 05000280/LER-1981-071-03, /03L-0:on 811216,following Reactor Trip,Specific Activity Samples of RCS Indicated Dose Equivalent I-131 Levels Greater than Tech Spec Limit.Caused by Fuel Element Defect in Reactor Core.Sampling Frequency to Be Increased + (ML20039F612)
- ML20039F613 + (ML20039F613)
- 05000327/LER-1981-150, Forwards LER 81-150/03L-0 + (ML20039F614)
- ML20039F616 + (ML20039F616)
- 05000280/LER-1981-076-03, /03L-0:on 811206,w/both Units at Cold Shutdown, Fuel Level in Diesel Fire Pump Fuel Tank Was Found to Be 215 Gallons,Below Tech Spec Limit.Caused by Administrative Oversite.Personnel Reinstructed + (ML20039F617)
- ML20039F618 + (ML20039F618)
- ML20039F619 + (ML20039F619)
- ML20039F621 + (ML20039F621)
- ML20039F622 + (ML20039F622)
- 05000327/LER-1981-150-03, /03L-0:on 811207,feedwater Flow Loop Declared Inoperable Due to Low Indication When Compared to Redundant Channels.Caused by Air in Transmitter Sense Lines.Sense Lines Bled & Vented + (ML20039F623)
- 05000280/LER-1981-077-03, /03L-0:on 811204,while Performing Periodic Test 18.6C,MOV-1867A Would Not Cycle When Operated from Control Room.Cause Not Stated + (ML20039F624)
- ML20039F625 + (ML20039F625)
- 05000324/LER-1981-129, Forwards LER 81-129/03L-0 + (ML20039F626)
- ML20039F628 + (ML20039F628)
- ML20039F629 + (ML20039F629)
- PNO-II-82-001, util & Bechtel Continuing Evaluation of Cause & Possible Consequences of Mispositioned Containment Spray Nozzles Identified During 5-yr Surveillance Test.Corrective Actions Not Expected to Delay 820301 Restart + (ML20039F630)
- ML20039F631 + (ML20039F631)
- ML20039F632 + (ML20039F632)
- ML20039F633 + (ML20039F633)
- ML20039F634 + (ML20039F634)
- 05000324/LER-1981-129-03, /03L-0:on 811204,channel Functional Test of Reactor Core Isolation Cooling Sys Steam Line High Differential Pressure Switches,Pt 2.1.12P,not Performed by Required Date.Caused by Personnel Error.Operator Counseled + (ML20039F635)
- BSEP-81-2486, RO 1-81-93:on 811231,discovered Required Action Per Tech Spec 3.3.1a Not Taken on 811228 When Reactor Water Level Instrument B21-LT-N017D-1 Found Inoperable.Required Action Taken & Investigation Begun.Instrument Being Repaired + (ML20039F636)
- ML20039F637 + (ML20039F637)