- 05000328/LER-1981-134, Forwards LER 81-134/03L-0 + (ML20039A560)
- ML20039A562 + (ML20039A562)
- ML20039A563 + (ML20039A563)
- ML20039A564 + (ML20039A564)
- 05000328/LER-1981-134-03, /03L-0:on 811111,relay Contacts for Fire Zone 367 Reactor Coolant Pump 3 Found Wired Normally Closed.Correct Configuration Is Normally Open.Caused by Error in Connection Drawings.Connection Drawings Revised + (ML20039A565)
- ML20039A566 + (ML20039A566)
- ML20039A567 + (ML20039A567)
- 05000328/LER-1981-126, Forwards LER 81-126/03L-0 + (ML20039A568)
- 05000328/LER-1981-126-03, /03L-0:on 811105,nuclear Instrumentation Sys Power Range Channel III (N-43) Declared Inoperable.Caused When Instrument Power Fuse Was Inadvertently Pulled Instead of Control Power Fuse.Procedures Revised + (ML20039A570)
- 05000327/LER-1981-132, Forwards LER 81-132/03L-0 + (ML20039A571)
- ML20039A573 + (ML20039A573)
- 05000327/LER-1981-132-03, /03L-0:on 811029,discovered That SI-137,RCS Water Inventory,Had Not Been Performed on Two Occasions within 72-h Between 811026-30.Caused When Steady State Conditions Required for SI-137 Were Not Achieved During Allotted Time + (ML20039A575)
- ML20039A576 + (ML20039A576)
- ML20039A577 + (ML20039A577)
- ML20039A578 + (ML20039A578)
- ML20039A579 + (ML20039A579)
- ML20039A580 + (ML20039A580)
- ML20039A582 + (ML20039A582)
- ML20039A584 + (ML20039A584)
- ML20039A586 + (ML20039A586)
- ML20039A588 + (ML20039A588)
- ML20039A590 + (ML20039A590)
- IR 05000409/1981019 + (ML20039A591)
- ML20039A593 + (ML20039A593)
- AECM-81-482, Interim Deficiency Rept Re Spherical Washer Subassemblies on Transamerica Delaval Div II Standby Diesel Generator, Initially Reported 811110.Analysis Incomplete.Final Rept by 820315.Possibly Reportable Per Part 21 + (ML20039A594)
- ML20039A595 + (ML20039A595)
- ML20039A596 + (ML20039A596)
- ML20039A597 + (ML20039A597)
- ML20039A598 + (ML20039A598)
- ML20039A600 + (ML20039A600)
- ML20039A604 + (ML20039A604)
- ML20039A606 + (ML20039A606)
- ML20039A607 + (ML20039A607)
- IR 05000237/1981027 + (ML20039A608)
- ML20039A610 + (ML20039A610)
- ML20039A611 + (ML20039A611)
- IR 05000010/1981016 + (ML20039A612)
- ML20039A613 + (ML20039A613)
- ML20039A614 + (ML20039A614)
- ML20039A616 + (ML20039A616)
- ML20039A617 + (ML20039A617)