Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML20037D653 + (ML20037D653)
- ML20037D656 + (ML20037D656)
- ML20037D657 + (ML20037D657)
- ML20037D658 + (ML20037D658)
- ML20037D659 + (ML20037D659)
- ML20037D660 + (ML20037D660)
- ML20037D661 + (ML20037D661)
- ML20037D662 + (ML20037D662)
- ML20037D663 + (ML20037D663)
- ML20037D665 + (ML20037D665)
- ML20037D666 + (ML20037D666)
- ML20037D667 + (ML20037D667)
- ML20037D670 + (ML20037D670)
- ML20037D672 + (ML20037D672)
- ML20037D674 + (ML20037D674)
- ML20037D675 + (ML20037D675)
- ML20037D676 + (ML20037D676)
- ML20037D677 + (ML20037D677)
- ML20037D679 + (ML20037D679)
- ML20037D680 + (ML20037D680)
- ML20037D681 + (ML20037D681)
- ML20037D682 + (ML20037D682)
- ML20037D683 + (ML20037D683)
- ML20037D685 + (ML20037D685)
- ML20037D687 + (ML20037D687)
- ML20037D688 + (ML20037D688)
- ML20037D689 + (ML20037D689)
- ML20037D690 + (ML20037D690)
- ML20037D693 + (ML20037D693)
- ML20037D695 + (ML20037D695)
- ML20037D696 + (ML20037D696)
- ML20037D697 + (ML20037D697)
- 05000219/LER-1981-034, Forwards LER 81-034/03L-0.Detailed Event Analysis Encl + (ML20037D699)
- ML20037D701 + (ML20037D701)
- 05000219/LER-1981-034-03, /03L-0:on 810722,control Rod Configuration Resulted in Peaking Factor of 110% of Allowable Limit. Apparently Caused by Personnel Error & Procedural Inadequacy in Review of Control Rod Configuration Instructions + (ML20037D702)
- ML20037D703 + (ML20037D703)
- ML20037D705 + (ML20037D705)
- ML20037D706 + (ML20037D706)
- ML20037D707 + (ML20037D707)
- 05000311/LER-1981-069, Forwards LER 81-069/03L-0.Detailed Event Analysis Encl + (ML20037D708)
- ML20037D710 + (ML20037D710)
- 05000311/LER-1981-069-03, /03L-0:on 810721,steam Generator 24 Steam Flow Channel 1 Discovered Reading High & Declared Inoperable. Caused by Erroneous Signal Due to High Multiplier 2FM-542B on Low End.Multiplier Adjusted & Channel Returned to Svc + (ML20037D711)
- 05000029/LER-1981-020, Forwards LER 81-020/03L-0 + (ML20037D712)
- 05000029/LER-1981-020-03, /03L-0:on 810723,during Refueling Outage in Mode 5,setpoint of TDR1 & TDR2 Found to Be Out of Tech Spec Limit.Caused by Setpoint Drift.Setpoint Adjusted & Relays (Model SSC12PCA) Retested Satisfactorily + (ML20037D714)
- 05000293/LER-1981-038, Forwards LER 81-038/03L-0 + (ML20037D715)
- ML20037D717 + (ML20037D717)
- 05000293/LER-1981-038-03, /03L-0:on 810720,pressure Switch PS-261-23A Found to Be 3 Psi Over Tech Spec Limit.Cause Unknown.Switch Recalibr + (ML20037D719)
- ML20037D720 + (ML20037D720)
- ML20037D721 + (ML20037D721)
- ML20037D722 + (ML20037D722)
- ML20037D724 + (ML20037D724)