- ML20034B252 + (ML20034B252)
- 05000325/LER-1990-004-03, :on 900322,injector Piping Failed on Chlorinator 5 Due to Improper Bonding of Piping.Caused by Sudden Separation of Chlorine Assembly at Junction of Reducing Bushing & Flange Adapter + (ML20034B253)
- ML20034B254 + (ML20034B254)
- 05000483/LER-1990-003, :on 900314,determined That Fire Protection Halon Sys for Either ESF Switchgear Rooms Could Have Disabled Both Trains of Class 1E Air Conditioner Units. Caused by Design Error.Trip Signal Removed + (ML20034B255)
- ML20034B256 + (ML20034B256)
- ML20034B258 + (ML20034B258)
- ML20034B259 + (ML20034B259)
- ML20034B261 + (ML20034B261)
- 05000413/LER-1990-016, :on 900305,Tech Spec Sample of Refueling Water Storage Tank Missed.Caused by Inappropriate Action Due to Failure to Recognize Need to Ensure Operable Borated Water Source.Chemistry Mgt Procedure Revised + (ML20034B262)
- 05000413/LER-1990-018, :on 900320,Tech Spec Violation Due to Missed Surveillance Resulting in Pressurizer Porv.Caused by Inappropriate Action.Procedures Revised to Ensure Equipment Operability Meets Tech Spec Requirements + (ML20034B264)
- ML20034B266 + (ML20034B266)
- 05000413/LER-1990-019, :on 900323,operations Personnel Inadvertently Pulled Supply Power Lead to Control Room Area Ventilation & Chilled Water Sys Train B Chiller Package.Caused by Deficient Procedure.Procedure Revised + (ML20034B271)
- 05000413/LER-1990-021, :on 900212,fire Doors Declared Inoperable to Permit Routing of Hose to Drain Component Cooling Sys Equipment & Surveillance Intervals Exceeded 1 H.Caused by Mgt Deficiency.Notice Re Fire Watch Issued + (ML20034B277)
- ML20034B279 + (ML20034B279)
- ML20034B281 + (ML20034B281)
- ML20034B282 + (ML20034B282)
- 05000425/LER-1990-002-03, :on 900320,generator Primary Differential Relay Energized,Causing Generator,Turbine & Reactor Trips & Fault Which Tripped Reserve Auxiliary Transformers a & B.Caused by Incorrect Tap Settings.Settings Corrected + (ML20034B283)
- ML20034B291 + (ML20034B291)
- BECO-90-060, Responds to NRC Bulletin 90-002 Re Loss of Thermal Margin Caused by Channel Box Bow.Channel Boxes for Second Bundle Lifetime Not Currently Used + (ML20034B293)
- 05000344/LER-1990-009, :on 900319,discrepancy in Setpoint of Function Generator Module in ESF Actuation Sys Noted.Caused by Inadequate Process for Ensuring Incorporation of Engineering Calculations in Calibr Settings + (ML20034B294)
- ML20034B295 + (ML20034B295)
- 05000254/LER-1990-008-01, :on 900321,discovered That Several Fire Zones Had Exceeded Amount of Fixed Fire Loading Stated in Exemption Requests to App R.Caused by Mgt Deficiency. Combustibles for Each Fire Zone Now Controlled + (ML20034B297)
- ML20034B298 + (ML20034B298)
- ML20034B299 + (ML20034B299)
- ML20034B300 + (ML20034B300)
- ML20034B302 + (ML20034B302)
- ML20034B304 + (ML20034B304)
- ML20034B305 + (ML20034B305)
- PY-CEI-NRR-1167, Responds to NRC Bulletin 90-002, Loss of Thermal Margin Channel Box Bow. No Fuel Channels Used for Second Bundle Lifetime at Facility.Requested Actions & Reporting Criteria of Bulletin Inapplicable to Facility + (ML20034B306)
- ML20034B307 + (ML20034B307)
- ML20034B308 + (ML20034B308)
- ML20034B309 + (ML20034B309)
- ML20034B310 + (ML20034B310)
- ML20034B311 + (ML20034B311)
- ML20034B312 + (ML20034B312)
- ML20034B314 + (ML20034B314)
- ML20034B315 + (ML20034B315)
- ML20034B316 + (ML20034B316)
- ML20034B318 + (ML20034B318)
- ML20034B319 + (ML20034B319)
- ML20034B320 + (ML20034B320)
- ML20034B321 + (ML20034B321)
- ML20034B322 + (ML20034B322)
- ML20034B324 + (ML20034B324)
- ML20034B325 + (ML20034B325)
- ML20034B326 + (ML20034B326)
- ML20034B327 + (ML20034B327)
- ML20034B328 + (ML20034B328)
- ML20034B329 + (ML20034B329)
- ML20034B330 + (ML20034B330)
- LIC-90-0359, Forwards Application for Amend to License DPR-40,changing Tech Specs Re Limiting Condition for Operation of Chemical & Vol Control Sys + (ML20034B331)