Proposed Tech Spec 5.3.2 Re Cladding of Control Rod Assemblies
ML20034B314
Person / Time
Site: Catawba  
Issue date: 04/12/1990
From:
DUKE POWER CO.
To:
Shared Package
ML20034B313 List:
References
NUDOCS 9004260388
Download: ML20034B314 (2)


Text

l' l

1 i

1 ATTACHMENT I PROPOSED CHANGES.TO THE TECHNICAL SPECIFICATIONS I

f L

l J

i Y

'9004260388 900412 _,

PDR fiDOCK0500g,o P

e

kbl-t *ewW q

3 3,..; >

a f E=

~

DESIGN FEATURES

-u t

{j-DESIGN PRESSURE AND TEMPERATURE

} f m, 5.2.2-The reactor containment vessel is designed and shall be maintained for a maximum internal pressure of 15 psig and a temoerature of 328 F.

m Ol 5.3 REACTOR CORE FUEL ASSEMBLIES

'l h{7 5.3.1~ The core shall'contain'193 fuel assemblies with each fuel assembly l) nominally containing 264 fuel rods clad with Zircaloy-4, excent that substitu-

{ tions of fuel rods by filler rods consisting of Zircaloy-4 or stainless steel, T,$ v or by vacancies, may be made Lin fuel assemblies if justified by cycle-specific-5 reload analyses using NRC-approved methodology.

Should more-than 30 rods in

@ Q the core, or 10 rods in any. assembly, be replaced per refueling, a special g report describing.the number of rods replaced ~will be submi.tted to the commis--

gd sion pursuant to Specification 6.9.2 within 30 days after cycle startup.

Each Q fuel rod shall have a nominal active fuel length of 144 inches.

Reload fuel o

k go shall be similar in physical design to the initial core loading and shall have 5my a maximum enrichment of 4.0 weight percent U-235 with a maximt.:a enrichment J1H tolerance of.

0.05 weight percent U-235.

(D CONTROL R0D ASSEMBLIES y

U k$ 5. 3. 2 The core shall contain 53 full-length control rod assemblies.

The full-

=0J length control rod assemblies shall contain a nominal 142 inches of absorber 0.p w material of which 102 inches shall be 100% boron carbide and remaining 40-inch 46 tip shall be 80% silver, 15% indium, and 5% cadmium.

l N"

Y lt -1, "l umTro l r shrai:be %u iurate'-iess stac1 t " g.

$w 8

2 7 "3 r Un

, all co 01 rods, e t for the rol rods i Rod Clus r o

E Con As RCC sh be c stain s

tubing.

r nin.

t, ms4er C

. J Assc 21, conm :1 rods i., con ^.

-g as'h ct 5.4 REACTOR COOLANT SYSTEM

~ >

1 4,_-

DESIGN PRESSURE AND TEMPERATURE k$

5.4.1 The Reactor Coolant System is designed and shall be maintained:

1 9 4 5

a.

In accordance with the Code requirements specified in Section 5.2 os d-

  • O of the FSAR, with allowance for normal degradation pursuant to the applicable Surveillance Requirements, b.

For a pressure a 2485 psig, and c.

For a temperature of 650 F, except for the pressurizer which-is 680 F.

VOLUME 5.4.2 The total water and steam volume of the Reactor Coolant System is

' i 12,040 100 cubic feet at a nominal T f 525 F.

avg 5.5 METEOROLOGICAL TOWER LOCATION 5.5.1 The meteorological tower shall be located as shown in Figure 5.1-1.

(

CATAWBA - UNITS 1 & 2 5-6 Amendment No. 64 (Unit 1) l Amendment No. 58 (Unit 2) 4t/