Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000293/LER-1981-060, Forwards LER 81-060/03L-0 + (ML20033C830)
- ML20033C832 + (ML20033C832)
- ML20033C834 + (ML20033C834)
- ML20033C835 + (ML20033C835)
- 05000293/LER-1981-060-03, /03L-0:on 811020,failure & Malfunction Rept Was Issued Which Indicated That Positioning of Average Power Range Monitor Bypass Switch Affects Control Rod Withdrawal Block Instrumentation + (ML20033C836)
- ML20033C837 + (ML20033C837)
- ML20033C838 + (ML20033C838)
- ML20033C839 + (ML20033C839)
- ML20033C840 + (ML20033C840)
- ML20033C841 + (ML20033C841)
- ML20033C842 + (ML20033C842)
- ML20033C843 + (ML20033C843)
- ML20033C844 + (ML20033C844)
- ML20033C845 + (ML20033C845)
- 05000305/LER-1981-035, Forwards LER 81-035/03L-0,LER 81-014/03X-1 & Corrected LER 81-015/03X-2 + (ML20033C846)
- ML20033C848 + (ML20033C848)
- B10333, Forwards Response to Request for Addl Info Re Util SAR for SEP Topic II-3.B, Flooding Potential & Protection Requirements + (ML20033C849)
- 05000305/LER-1981-035-03, /03L-0:on 811030,during Sampling & Analysis of Chemical & Vol Control Sys,Noted Monitor Tank Indicated Total Tritium Activity Exceeded Tech Specs.No Cause Stated. Liquid Transferred to Reduce Setpoint + (ML20033C850)
- 05000219/LER-1981-050, Forwards LER 81-050/03L-0.Detailed Event Analysis Encl + (ML20033C851)
- 05000305/LER-1981-014-03, /03X-1:on 810507,during Test of Presurizer Level Channels,Found Transmitter to Channel Lt 427 Out of Spec Low,Implying That High Level Reactor Trip Relay Would Have Tripped.Will Change Transmitters + (ML20033C853)
- ML20033C854 + (ML20033C854)
- 05000219/LER-1981-050-03, /03L-0:on 811015,core Spray Pressure Switch Closed Alarm Failed to Clear When Reactor Pressure Increased Above RE18 Pressure Switch Setpoint.Caused by Low Reset Point on Core Spray Pump Discharge Pressure Switch RV29C + (ML20033C856)
- ML20033C857 + (ML20033C857)
- A01929, Responds to NUREG-0737,Item II.K.3.44 Re Evaluation of Anticipated Transients Combined W/Single Failure,Per NRC Request.Analysis Assumptions & Initial Conditions Used for Generic Analysis Are Representative for Facility + (ML20033C861)
- ML20033C862 + (ML20033C862)
- W3P81-2606, Responds to Generic Ltr 81-21 Re Natural Circulation cooldown.C-E Owners Group CE-NPSD-154 Analysis Providing Recommendations Re Natural Circulation Evolutions Discussed. Planned Natural Circulation Test Program Outlined + (ML20033C864)
- ML20033C865 + (ML20033C865)
- ML20033C866 + (ML20033C866)
- ML20033C867 + (ML20033C867)
- ML20033C868 + (ML20033C868)
- ML20033C869 + (ML20033C869)
- 05000333/LER-1981-078, Forwards LER 81-078/03L-0 + (ML20033C873)
- 05000333/LER-1981-078-03, /03L-0:on 811103,during Local Leak Rate Tests, Drywell Purge Exhaust Outboard Isolation Valve 27-AOV-114 Found W/Leakage That May Exceed Tech Spec.Cause Undetermined.Valves May Require Repair + (ML20033C875)
- 05000267/LER-1981-069, Forwards LER 81-069/03L-0.Detailed Event Analysis Encl + (ML20033C876)
- 05000267/LER-1981-069-03, /03L-0:on 811104-09, Plant Operated in Degraded Mode.Caused by Moisture in Pcrv W/Reactor Power Less than 2% Resulting in Increased Offgassing When Plant Taken to High Power Levels for Core Temp Fluctuation Testing + (ML20033C878)
- PNO-I-81-124, on 811116,United Priority Transit Corp Auto Carrying Approx 13 Packages of Medical Radioisotopes Involved in Accident Near Reading,Pa.Packages Found Intact by PA Bureau of Radiological Health Representatives + (ML20033C879)
- ML20033C882 + (ML20033C882)
- ML20033C885 + (ML20033C885)
- 05000272/LER-1981-073, Forwards LER 81-073/03L-0.Detailed Event Analysis Encl + (ML20033C886)
- ML20033C887 + (ML20033C887)
- 05000272/LER-1981-073-03, /03L-0:on 810722,control Operator Noticed Channel 1 of Containment Pressure hi-hi Indicators Spiking.Caused by Steam Leak from Nearby Steam Generator Blowdown Line Blowing on Containment hi-hi Channel 1 Transmitter + (ML20033C888)
- ML20033C889 + (ML20033C889)
- 05000316/LER-1981-061, Forwards LER 81-061/03L-0 + (ML20033C890)
- 05000316/LER-1981-061-03, /03L-0:on 811030,during Reactor Startup at 20% Power,Steam Generator Flow 3 Channel 1 Failed Low.Caused by Air Trapped in Sensing Lines Causing Incorrect Transmitter Output.Sensing Lines Blown Down + (ML20033C892)
- ML20033C893 + (ML20033C893)
- 05000285/LER-1981-010, Forwards LER 81-010/03L-0 + (ML20033C894)
- ML20033C896 + (ML20033C896)
- 05000285/LER-1981-010-03, /03L-0:on 811027,D/LC-383-1 Left & Right Switches & D/LC-383-2 Left & Right Switches Found Out of Setpoint Tolerances.Caused by D Channel Level Switches Drifting Out of Calibr for Unknown Reasons.Switches Recalibr + (ML20033C898)
- ML20033C901 + (ML20033C901)
- IR 05000245/1981013 + (ML20033C903)
- ML20033C905 + (ML20033C905)