- 05000302/LER-1981-065-03, /03L-0:on 811008,during Performance of Remote Shutdown Instrumentation Calibr,Transmitters SP-1A-LT2 & SP-1B-LT2 Found Out of Tolerance.Caused by Instrument Drift. Instruments Recalibr + (ML20032D003)
- ML20032D004 + (ML20032D004)
- ML20032D006 + (ML20032D006)
- 05000336/LER-1981-034-03, /03L-0:on 811008,routine Surveillance Indicated Excore Detector Channel D Had Potentiometer in Core Protection Calculator That Was Set Nonconservatively.Caused by New Detector W/Improper Setting + (ML20032D007)
- ML20032D009 + (ML20032D009)
- ML20032D010 + (ML20032D010)
- ML20032D012 + (ML20032D012)
- ML20032D013 + (ML20032D013)
- ML20032D014 + (ML20032D014)
- ML20032D015 + (ML20032D015)
- ML20032D016 + (ML20032D016)
- ML20032D017 + (ML20032D017)
- ML20032D018 + (ML20032D018)
- ML20032D019 + (ML20032D019)
- 05000311/LER-1981-109, Forwards LER 81-109/03L-0.Detailed Event Analysis Encl + (ML20032D020)
- ML20032D022 + (ML20032D022)
- ML20032D023 + (ML20032D023)
- ML20032D025 + (ML20032D025)
- 05000311/LER-1981-109-03, /03L-0:on 811006,while Performing Design Change Package Mods,Vitro Labs Representative Allowed Solder to Fall Into 15-volt Power Supply for 2A Safeguards Equipment Control.Caused by Personnel Error.Power Supply Replaced + (ML20032D026)
- 05000336/LER-1981-035, Forwards LER 81-035/03L-0 + (ML20032D027)
- ML20032D029 + (ML20032D029)
- IR 05000416/1981038 + (ML20032D030)
- 05000336/LER-1981-035-03, /03L-0:on 811008,found Pressurizer Water Level & Auxiliary Feedwater Flow Rate Channel Checks Not Performed During Aug & Sept 1981.Caused by Failure to Incorporate Changes When Procedure Form Was Revised + (ML20032D033)
- ML20032D034 + (ML20032D034)
- 05000293/LER-1981-059, Forwards LER 81-059/03L-0 + (ML20032D035)
- 05000259/LER-1981-061, Forwards LER 81-061/03L-0 + (ML20032D037)
- 05000269/LER-1981-019-01, /01T-0:on 811019 & 20,four Liquid Waste Releases Made W/Inoperable Effluent Monitors & Inadequate Redundant Samples of Water Releases.Caused by Failure to Identify Change in Sample Point.Sampling Procedure Revised + (ML20032D039)
- ML20032D040 + (ML20032D040)
- 05000259/LER-1981-061-03, /03L-0:on 811010,diesel Generator C Shut Down Prior to Normal Time Frame to Troubleshoot & Time ECR Relay. Cause Undetermined.Ecr Relay Calibr & Time Acceptable + (ML20032D041)
- ML20032D042 + (ML20032D042)
- ML20032D044 + (ML20032D044)
- IR 05000309/1981017 + (ML20032D048)
- ML20032D049 + (ML20032D049)
- ML20032D052 + (ML20032D052)
- 05000302/LER-1981-063, Forwards LER 81-063/03L-0 + (ML20032D053)
- ML20032D055 + (ML20032D055)
- ML20032D056 + (ML20032D056)
- 05000302/LER-1981-063-03, /03L-0:on 811005, 12 & 14,various Snubbers Discovered Inoperable.Snubber EFH-106 Failed Due to Bent shaft.RCH-53 & 85 Had Cracked Aluminum bushings.DHR-28, MSH-253 & MUH-46A Failed Due to Excessive Bleed Rate + (ML20032D057)
- ML20032D058 + (ML20032D058)
- ML20032D059 + (ML20032D059)
- 05000302/LER-1981-064, Forwards LER 81-064/03L-0 + (ML20032D060)
- ML20032D062 + (ML20032D062)
- ML20032D064 + (ML20032D064)
- ML20032D065 + (ML20032D065)
- ML20032D066 + (ML20032D066)
- ML20032D067 + (ML20032D067)
- ML20032D068 + (ML20032D068)
- 05000302/LER-1981-064-03, /03L-0:on 811007,while Performing Engineered Safeguards Channel Calibr,Esf Actuation Sys Reactor Coolant Pressure Transmitter RC-2A-PT3 Discovered Out of Tolerance. Caused by Instrument Drift.Instrument Recalibr + (ML20032D069)
- ML20032D070 + (ML20032D070)
- ML20032D071 + (ML20032D071)
- ML20032D072 + (ML20032D072)