Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000245/LER-1981-030-03, /03L-0:on 810914,during Turbine Control Valve Fast Closure Functional & Calibr test,two-time Delay Relays Exceeded Tech Spec.Caused by Setpoint Drift.Relays Readjusted + (ML20031H388)
- 05000316/LER-1981-046-03, /03L-0:on 810922,during Surveillance Test,Channel 2 Containment Pressure High Protection Bistable 2PB-936B Found to Be Actuating at Value Equal to 1.319 Psig.Caused by Setpoint Drift.Bistable Replaced.Lugged Resistor Soldere + (ML20031H389)
- ML20031H390 + (ML20031H390)
- IR 05000333/1981013 + (ML20031H391)
- ML20031H393 + (ML20031H393)
- ML20031H394 + (ML20031H394)
- 05000293/LER-1981-052, Forwards LER 81-052/03L-0 + (ML20031H395)
- ML20031H397 + (ML20031H397)
- 05000315/LER-1981-043-03, /03L-0:on 810919,during Surveillance Test on Solid State Protection Sys,Logic Test Position Tested Unsatisfactorily.Caused by Failure of Westinghouse Universal Card A-210.Logic Card Replaced + (ML20031H399)
- ML20031H400 + (ML20031H400)
- JAFP-81-0972, Responds to NRC Re Violations Noted in IE Insp Rept 50-333/81-13.Corrective Actions Withheld (Ref 10CFR2.790) + (ML20031H401)
- 05000255/LER-1981-040, Forwards LER 81-040/01T-0 + (ML20031H402)
- ML20031H404 + (ML20031H404)
- ML20031H405 + (ML20031H405)
- IR 05000358/1981022 + (ML20031H407)
- ML20031H408 + (ML20031H408)
- 05000293/LER-1981-052-03, /03L-0:on 810918,torus Temp Tech Spec Limit Exceeded.Caused by Operator Distraction by Other Reportable Event.Pumps Activated to Induce Cooling.Torus Temp Info to Displayed on Main Control Room Console + (ML20031H409)
- ML20031H410 + (ML20031H410)
- 05000255/LER-1981-040-01, /01T-0:on 811005,during Testing to Determine Setpoint of Pressurizer Relief Valve RV-1039,pressure Exceeded Tech Spec Range.Cause Unknown.Valve Setpoint Reset.Remaining Safety Valves to Be Tested + (ML20031H412)
- ML20031H413 + (ML20031H413)
- ML20031H414 + (ML20031H414)
- ML20031H416 + (ML20031H416)
- 05000318/LER-1981-024, Forwards Updated LER 81-024/01X-1 + (ML20031H417)
- ML20031H419 + (ML20031H419)
- ML20031H420 + (ML20031H420)
- ML20031H424 + (ML20031H424)
- ML20031H425 + (ML20031H425)
- 05000318/LER-1981-024-01, Auxiliary Feedwater Pump 21 Inadvertently Tripped by Contractor Personnel Working in Area.Personnel Instructed on Operation of Trip Device & Alarm Installed to Indicate Tripping + (ML20031H427)
- IR 05000382/1981026 + (ML20031H428)
- ML20031H429 + (ML20031H429)
- ML20031H430 + (ML20031H430)
- ML20031H431 + (ML20031H431)
- IR 05000346/1981017 + (ML20031H434)
- 05000334/LER-1981-086, Forwards LER 81-086/03L-0 + (ML20031H435)
- ML20031H437 + (ML20031H437)
- ML20031H439 + (ML20031H439)
- ML20031H441 + (ML20031H441)
- ML20031H442 + (ML20031H442)
- ML20031H443 + (ML20031H443)
- 05000334/LER-1981-086-03, /03L-0:on 810910,electrical Arcing Observed Inside Battery Charger Compartment 4 During Test.Caused by Bad Electrical Wiring Connection within Charger.High Resistance Across Point Caused Arcing When Charger Increased + (ML20031H444)
- ML20031H445 + (ML20031H445)
- 05000267/LER-1981-059-03, /03L-0:on 810914,21,1005,06 & 08,w/plant Operating at Power,Class I Snubbers Removed for Insp of Cylinder Tie Rods.Caused by Possible over-torquing.No Defects Found.Maint Procedures Revised + (ML20031H447)
- ML20031H450 + (ML20031H450)
- ML20031H452 + (ML20031H452)
- IR 05000206/1981028 + (ML20031H453)
- ML20031H455 + (ML20031H455)
- ML20031H458 + (ML20031H458)
- ML20031H459 + (ML20031H459)
- ML20031H460 + (ML20031H460)
- ML20031H463 + (ML20031H463)