- 05000364/LER-1981-034, Forwards LER 81-034/03L-0 & 81-037/03L-0.W/o Encl LERs 81-037/03L-0 + (ML20010G634)
- ML20010G635 + (ML20010G635)
- ML20010G636 + (ML20010G636)
- ML20010G637 + (ML20010G637)
- 05000364/LER-1981-034-03, /03L-0:on 810809,train a Boron Injection Tank Heat Tracing Had Been Inoperable Since 810711.Caused by Personnel Error.Supply Breaker Had Been Tagged Out for Replacement of Burned Out Heater on 810711 + (ML20010G639)
- ML20010G640 + (ML20010G640)
- 05000338/LER-1981-069, Forwards LER 81-069/03L-0 + (ML20010G642)
- ML20010G643 + (ML20010G643)
- ML20010G644 + (ML20010G644)
- ML20010G645 + (ML20010G645)
- ML20010G646 + (ML20010G646)
- ML20010G647 + (ML20010G647)
- ML20010G648 + (ML20010G648)
- 05000338/LER-1981-069-03, /03L-0:on 810819,found Two Containment Isolation Valves Were Not Leak Tested After Maint.Caused by Valve Repair Using General Valve Mechanical Maint Procedures Which Omit Leak Test.Maint Procedure Revised + (ML20010G649)
- ML20010G650 + (ML20010G650)
- ML20010G651 + (ML20010G651)
- ML20010G652 + (ML20010G652)
- 05000317/LER-1981-064, Forwards LER 81-064/03L-0 + (ML20010G654)
- ML20010G655 + (ML20010G655)
- ML20010G656 + (ML20010G656)
- 05000317/LER-1981-064-03, /03L-0:on 810813,diesel Generator 11 Lost Speed Control & Several Control Room Indications During post-maint Testing.Caused by Blown Fuse.Fuse Replaced & Generator Tested + (ML20010G657)
- ML20010G658 + (ML20010G658)
- 05000346/LER-1981-047, Forwards LER 81-047/03L-0 + (ML20010G659)
- ML20010G660 + (ML20010G660)
- ML20010G661 + (ML20010G661)
- 05000309/LER-1981-019, Forwards LER 81-019/03L-0 + (ML20010G662)
- ML20010G664 + (ML20010G664)
- 05000346/LER-1981-047-03, /03L-0:on 810816,steady State Quadrant Power Tilt Limit Was Exceeded Due to Large Difference in RCS Cold Leg Temp.Caused by Mismatch in Feedwater Flows to once-through Steam Generators.Plant Startup Procedure Modified + (ML20010G665)
- 05000309/LER-1981-019-03, /03L-0:on 810904,channel D,Temp Monitor/Lp Calculator Setpoint Indicated Below Tech Spec Limit.Caused by Faulty Amplifier Module within Margin Calculator.Module Replaced & Setpoints Verified + (ML20010G666)
- IR 05000298/1981013 + (ML20010G667)
- ML20010G668 + (ML20010G668)
- ML20010G669 + (ML20010G669)
- ML20010G670 + (ML20010G670)
- ML20010G671 + (ML20010G671)
- ML20010G673 + (ML20010G673)
- ML20010G674 + (ML20010G674)
- ML20010G675 + (ML20010G675)
- ML20010G676 + (ML20010G676)
- ML20010G677 + (ML20010G677)
- ML20010G680 + (ML20010G680)
- ML20010G681 + (ML20010G681)
- ML20010G682 + (ML20010G682)
- ML20010G683 + (ML20010G683)
- ML20010G685 + (ML20010G685)
- 05000220/LER-1981-042, Forwards LER 81-042/04T-0 + (ML20010G688)
- ML20010G689 + (ML20010G689)
- A810025, Commits to Four Listed Criteria Re Future Disc Insps for Westinghouse Low Pressure Turbines.Util Working W/ Westinghouse in Replacing Low Pressure Turbine Rotors + (ML20010G690)
- ML20010G691 + (ML20010G691)
- ML20010G692 + (ML20010G692)
- 05000220/LER-1981-042-04, /04T-0:on 810831,during Weekly Environ Radiation Monitor Insp,Only Six Monitors Found Functioning Due to Defective Power Supply Units.Cause Unknown.Portable Monitor Installed + (ML20010G693)
- ML20010G695 + (ML20010G695)