- ML19343C556 + (ML19343C556)
- 05000296/LER-1980-056-03, /03L-0:on 801215,during Refueling,Diesel Generator Voltage Available Relay Found Dropped Out.Caused by Open Wire in Cable.Cable Replaced + (ML19343C557)
- ML19343C558 + (ML19343C558)
- ML19343C559 + (ML19343C559)
- ML19343C560 + (ML19343C560)
- ML19343C561 + (ML19343C561)
- ML19343C563 + (ML19343C563)
- ML19343C564 + (ML19343C564)
- ML19343C565 + (ML19343C565)
- ML19343C566 + (ML19343C566)
- ML19343C568 + (ML19343C568)
- ML19343C569 + (ML19343C569)
- 05000271/LER-1981-008, Forwards LER 81-008/03L-0 + (ML19343C571)
- ML19343C572 + (ML19343C572)
- 05000271/LER-1981-008-03, /03L-0:on 810218,reactor Core Isolation Cooling Pump Tripped.Caused by Electrical Cable Connector Detaching from Egr.Connector Replaced + (ML19343C573)
- 05000302/LER-1981-011, Forwards LER 81-011/01T-1 + (ML19343C574)
- ML19343C575 + (ML19343C575)
- ML19343C576 + (ML19343C576)
- 05000302/LER-1981-011-01, /01T-1:on 810306,containment Isolation Valves CAV-1,3,4,5 & 126 Found Incapable of Meeting Environ Qualification During Evaluation of IE Bulletin 79-01B.Caused by Potential Electrical Short Due to Flooding After LOCA + (ML19343C577)
- 05000302/LER-1981-012, Forwards LER 81-012/03L-0 + (ML19343C580)
- ML19343C581 + (ML19343C581)
- ML19343C582 + (ML19343C582)
- 05000302/LER-1981-012-03, /03L-0:on 810219,Limitorque-operated Containment Isolation Valves MUV-260 & 261 Failed to Close.Cause Unknown.Torque Switch MUV-261 Replaced & Operability Restored on 810224.Investigation Continuing + (ML19343C583)
- ML19343C584 + (ML19343C584)
- ML19343C585 + (ML19343C585)
- ML19343C586 + (ML19343C586)
- ML19343C587 + (ML19343C587)
- 05000296/LER-1981-011, Forwards LER 81-011/03L-0 + (ML19343C588)
- ML19343C589 + (ML19343C589)
- 05000296/LER-1981-011-03, /03L-0:on 810224,coupling Damage Was Found on 3DA Rmov Bd MG Set.Caused by Misalignment & Loss of Lubricant.Coupling Seal Found Separated.Mg Set Realigned, Coupling Replaced & All Other Set Couplings Repaired + (ML19343C590)
- ML19343C591 + (ML19343C591)
- ML19343C592 + (ML19343C592)
- ML19343C594 + (ML19343C594)
- ML19343C596 + (ML19343C596)
- ML19343C600 + (ML19343C600)
- 05000325/LER-1981-027, Forwards LER 81-027/03L-0 + (ML19343C602)
- ML19343C603 + (ML19343C603)
- ML19343C604 + (ML19343C604)
- 05000325/LER-1981-027-03, /03L-0:on 810216,diesel Generator Lockout Received on Diesel Generator 1 While Closing Door to PT Compartment on 4160-volt Switchgear for Emergency Bus E-1.Caused by Door Hitting Seal Hard,Causing Lockout Relay to Pick Up + (ML19343C605)
- ML19343C606 + (ML19343C606)
- ML19343C607 + (ML19343C607)
- ML19343C609 + (ML19343C609)
- ML19343C611 + (ML19343C611)
- ML19343C612 + (ML19343C612)
- ML19343C613 + (ML19343C613)
- ML19343C614 + (ML19343C614)
- ML19343C615 + (ML19343C615)
- ML19343C616 + (ML19343C616)
- ML19343C617 + (ML19343C617)
- ML19343C618 + (ML19343C618)
- ML19343C619 + (ML19343C619)