- 05000213/LER-1976-006-03, /03L-0:on 760203,emergency Diesel EG-2B Tripped on Overspeed.Caused by Calibr Tool Left in Injector Rack Following Recent Governor Replacement & Adjustments.Close Adherence to QA Procedures Will Prevent Recurrence + (ML19343C356)
- 05000213/LER-1976-012-01, /01T-0:on 760617,during Refueling mode,1,600 AMP Frame Size Tie Breaker 6T7 Opened de-energizing Bus 6 & Allowing 1B RHR Pump to Lose Power.Caused by Inadequate Procedures Re 480 Volt Bus Tie Breaker Overload + (ML19343C357)
- 05000213/LER-1976-002-01, /01T-0:on 760122,MSIVA Failed to Close Completely in Required Time & Limit Switch Malfunctioned.Caused by Frozen Solenoid Due to sub-zero Weather & Moisture in MSIV Air Operator & Limit Switch Internal Corrosion,Respectively + (ML19343C358)
- ML19343C359 + (ML19343C359)
- ML19343C362 + (ML19343C362)
- ML19343C363 + (ML19343C363)
- ML19343C365 + (ML19343C365)
- ML19343C366 + (ML19343C366)
- ML19343C367 + (ML19343C367)
- ML19343C369 + (ML19343C369)
- ML19343C370 + (ML19343C370)
- ML19343C371 + (ML19343C371)
- ML19343C372 + (ML19343C372)
- ML19343C373 + (ML19343C373)
- ML19343C374 + (ML19343C374)
- ML19343C375 + (ML19343C375)
- NUREG-0751, Forwards NUREG-0751, Review & Evaluation of NRC Safety Research Program for FY82 + (ML19343C376)
- ML19343C378 + (ML19343C378)
- NUREG-0757, Notifies of Issuance of NUREG-0757, Radon Releases from U Mining & Milling & Calculated Health Effects, Which Contains New Info Potentially Relevant & Matl to Aslab Proceedings + (ML19343C379)
- ML19343C380 + (ML19343C380)
- ML19343C381 + (ML19343C381)
- ML19343C382 + (ML19343C382)
- ML19343C383 + (ML19343C383)
- ML19343C385 + (ML19343C385)
- ML19343C386 + (ML19343C386)
- ML19343C388 + (ML19343C388)
- ML19343C389 + (ML19343C389)
- ML19343C390 + (ML19343C390)
- ML19343C391 + (ML19343C391)
- ML19343C393 + (ML19343C393)
- ML19343C394 + (ML19343C394)
- ML19343C395 + (ML19343C395)
- ML19343C396 + (ML19343C396)
- ML19343C397 + (ML19343C397)