Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19343C272 + (ML19343C272)
- ML19343C274 + (ML19343C274)
- 05000213/LER-1976-017-03, /03L-0:on 760720,loop 2 Steam Line Flow Indicator Failed Low,Annunciating on Main Control Board.Caused by Leaking Sensing Line cross-threaded Fitting on High Side of Loop 2 Pressure Transmitter.Damage Fitting Replaced + (ML19343C275)
- 05000213/LER-1976-015-03, /03L-0:on 760629,abnormal Pressure Noted on Waste Gas Decay Tank TK-6013.Caused by Rupture Disk Rupture at 52 Psig,Rather than 225 Psig.Rupture Disk Replaced & Plant Design Change Prepared to Relocate Rupture Disk + (ML19343C276)
- ML19343C277 + (ML19343C277)
- 05000213/LER-1976-014, /01T-0:on 760626,power to Residual Heat Removal Pump Interrupted for 30-s.Caused by Automatic Circuit Breaker Trip on Station Svc Transformer Due to Spurious 115 Kv Fault Signal.Backup Sensing Circuits to Be Changed + (ML19343C278)
- ML19343C281 + (ML19343C281)
- 05000213/LER-1976-008-03, /03L-0:on 760330,rupture Disk PSE-1172B Ruptured, Causing Waste Gas Decay Tank TK-60B Pressure to Drop.Cause Under Investigation by Vendor.Disk Removed for Insp & Sys Design to Be Reviewed + (ML19343C282)
- 05000213/LER-1976-007-03, /03L-0:on 760219,nuclear Instrumentation Channel 34 Overpower Trip Setpoint Exceeded Limits.Caused by Normal Instrument Drift.Setpoint Adjusted to Allow for Some Drift W/O Exceeding Limit + (ML19343C283)
- 05000213/LER-1976-005-03, /03L-0:on 760124,1A Centrifugal Charging Pump Outboard Seal Leaked Excessively.Caused by O-ring Failure. Seal Replaced + (ML19343C284)
- ML19343C285 + (ML19343C285)
- 05000213/LER-1976-001-01, /01T-0:on 760122,steam Flow Transmitter Sensing Lines Froze,Simulating High Steam Flow Trip Signals in Reactor Protection Sys & Tripping Reactor.Caused by sub-zero Weather & Openings Inadvertently Left in Wall + (ML19343C286)
- 05000213/LER-1976-003-03, /03L-0:on 760202,Channel 33 Overpower Trip Setpoint Exceeded Limit.Caused by Normal Instrument Drift. Setpoint Reset to Allow for Drift W/O Exceeding Limit + (ML19343C287)
- ML19343C288 + (ML19343C288)
- ML19343C290 + (ML19343C290)
- ML19343C292 + (ML19343C292)
- ML19343C293 + (ML19343C293)
- ML19343C294 + (ML19343C294)
- ML19343C295 + (ML19343C295)
- ML19343C296 + (ML19343C296)
- ML19343C297 + (ML19343C297)
- ML19343C298 + (ML19343C298)
- ML19343C299 + (ML19343C299)
- ML19343C301 + (ML19343C301)
- ML19343C302 + (ML19343C302)
- ML19343C303 + (ML19343C303)
- ML19343C304 + (ML19343C304)
- ML19343C305 + (ML19343C305)
- ML19343C306 + (ML19343C306)
- 05000245/LER-1977-003-03, /03L-0:on 770112,while Performing Surveillance on Drywell Pressure Switches,One Switch Tripped at Value Higher than Tech Specs Limit.Caused by Setpoint Drift.Switch Adjusted to Required Setpoint + (ML19343C307)
- ML19343C309 + (ML19343C309)
- ML19343C310 + (ML19343C310)
- ML19343C311 + (ML19343C311)
- ML19343C312 + (ML19343C312)
- ML19343C313 + (ML19343C313)
- ML19343C315 + (ML19343C315)
- IR 05000219/1972032 + (ML19343C316)
- ML19343C317 + (ML19343C317)
- IR 05000219/1972031 + (ML19343C318)
- ML19343C319 + (ML19343C319)
- IR 05000219/1972030 + (ML19343C321)
- ML19343C322 + (ML19343C322)
- ML19343C323 + (ML19343C323)
- ML19343C324 + (ML19343C324)
- ML19343C325 + (ML19343C325)
- ML19343C326 + (ML19343C326)
- ML19343C327 + (ML19343C327)
- ML19343C328 + (ML19343C328)
- ML19343C329 + (ML19343C329)
- ML19343C330 + (ML19343C330)
- ML19343C331 + (ML19343C331)