(~) 'n t 2n L) / / tt a L2 CODSumBfS POYlCr j

Company o.n.r., on.c..: :na w.. u.chissa A.=nv. Jacm.on. uicnioan 402ei Area coa. si7 7ee oe so February 16, 1978 Mr James G Keppler Office of Inspection and Enforce =enT, Region III US Nuclear Regulatory Cocsission 799 Roosevelt Road Glen Ellyn, IL 60137 DOCKET 50-155 - LICENSE DPR BIG ROCK l'0 INT PLANT - RESP 03SE TO IE E1LETIN 78-01 IE Bulletin 78-01 requested information concerning the use of General Electric CR-120A relays and specified required action upon confirmation. A thorough review of Big Rock Point Plant drawings and documentation indicated that none of the cited relays are in use. This initial conclusion was confirmed by a physical check of various control panels throughout the plant. Further, a search of the stockroom and a review of outstanding General Electric purchase requisitions revealed no suspect relays on order or in stock. Thus, it is con-claded that IE Bulletin 78-01 is not applicable to Big Rock Point.

" n.

Willia: S SkibitsP.y Senior Licensing Engineer CC: DKDavis, USNRC v\\

(P E 3 0 1 1978 Plobc%oo353