Responds to IE Bulletin 76-06, Diaphragm Failures in Air Operated Auxiliary Actuators for Safety Relief Valves. Insp of Valves Indicated That No Insulation Installed on Air Operator & All Diaphragms in Excellent Condition
ML19343C311
Person / Time
Site: Millstone Dominion icon.png
Issue date: 08/02/1976
From: Switzer D
NORTHEAST NUCLEAR ENERGY CO.
To: Oreilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
IEB-76-06, IEB-76-6, NUDOCS 8103090314
Download: ML19343C311 (1)


Text

,

ll ?

$L4 P. O BOX 270 HARTF ORD. CONNE011 CUT CG101 2mmu NORTHEAST stOCLEAR ENERGY COMPANY A NOR1Ht'AST UTILillES COMPANY Docket No. 50-245 August 2, 1976 Mr. James P. O'Reilly Director, Region I Office of Inspection and Enforcement U. S. Nuclear Regulatory Commission 631 Park Avenue King of Prussia, Pennsylvania 19406

Reference:

Office of Inspection and Enforcement Bulletin No. 76-06

Dear Mr. O'Reilly:

This letter is in response to IE Bulletin No. 76-06 regaraing failures of diaphragms in air operators for safety /rclief valves. Presently, Millstone Unit 1 has three safety / relief valves, of the type in question, installed in the Main Steam System. These valves are manufactured by the Target Rock Corporation and are a Model No. 67F.

During a plant shutdown on July 17, 1976, these valves were inspected for the problems described in IE Bulletin No. 76-06.

The inspection re-

.vealed that there is no thermal insulation installed on the air operator and all diaphregms were in excellent shape. The air operators were also tested and operation was satisfactory.

Presently, th'

._Jures used for disassembly and inspection of these valves are being revised to include inspection of the diaphragms. The revision will also require diaphragm replacement within the manufacturer's l

recommended five year service life.

No action regarding the shelf life l

of the diaphragm is necessary because the manufacturer's recommended shelf l

life is indefinite.

All procedure changes will be completed prior to the start of our l

next refueling outage which is scheduled for October 1, 1976.

It is felt that these procedure changes along with our recent inspection and testing satisfy the reporting requirements of IE Bulletin No. 76-06.

Very truly yours, NORTHEAST NUCLEAR ENERGY COMPANY 00 j

D. C. Switzer b President

/

DCS:FWH/PP: gal cc: NRC Office of Inspection and Enforcement-l

~ Division of Reactor Inspection Programs

/

ggg Washington, D.C.

20555

-