Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19338C647 + (ML19338C647)
- ML19338C648 + (ML19338C648)
- ML19338C650 + (ML19338C650)
- ML19338C652 + (ML19338C652)
- ML19338C653 + (ML19338C653)
- ML19338C656 + (ML19338C656)
- ML19338C657 + (ML19338C657)
- ML19338C659 + (ML19338C659)
- ML19338C661 + (ML19338C661)
- ML19338C662 + (ML19338C662)
- ML19338C663 + (ML19338C663)
- ML19338C665 + (ML19338C665)
- PM-80-784, Forwards Monthly Operating Rept for Jul 1980 + (ML19338C668)
- ML19338C669 + (ML19338C669)
- ML19338C670 + (ML19338C670)
- ML19338C672 + (ML19338C672)
- ML19338C673 + (ML19338C673)
- 05000334/LER-1980-055-01, /01P-0:on 800811,all Three Reactor Coolant Loop RTD Manifolds Determined to Be Overstressed During Seismic Event at Respective 2-inch to 3-inch Reducers.Cause Unknown. Each Line Will Be Reinforced by Anchors + (ML19338C674)
- 05000334/LER-1980-056-01, /01P-0:on 800811,discovered That Significant Overstress Condition on High Head Safety Injection Lines to Respective Hot Lines Could Occur During Seismic Event.Caused by Inadequately Sized U Bolts & Undersized Weld Supports + (ML19338C675)
- 05000334/LER-1980-053-01, /01P-0:on 800811,significant Overstress Condition on Charging Lines Found Possible During Seismic Event.Caused by Inadequately Sized U Bolts.Bolts Will Be Replaced with 3-inch Pipe Clamp.Support Will Be Modified + (ML19338C676)
- 05000334/LER-1980-054-01, /01P-0:on 800811,significant Overstress Condition Found Possible on Safety Injection Line from High Head Safety Injection Pumps to Reactor Coolant Sys Hot Legs, During Seismic Event.Caused by Inadequate Weld + (ML19338C678)
- ML19338C679 + (ML19338C679)
- ML19338C681 + (ML19338C681)
- ML19338C683 + (ML19338C683)
- ML19338C684 + (ML19338C684)
- ML19338C686 + (ML19338C686)
- ML19338C687 + (ML19338C687)
- ML19338C688 + (ML19338C688)
- ML19338C689 + (ML19338C689)
- ML19338C690 + (ML19338C690)
- 05000338/LER-1980-066, Forwards LER 80-066/03L-0 + (ML19338C691)
- ML19338C693 + (ML19338C693)
- ML19338C694 + (ML19338C694)
- ML19338C696 + (ML19338C696)
- 05000338/LER-1980-066-03, /03L-0:on 800720,containment Bulk Average Temp Exceeded Tech Spec Limit.Caused by Period of Abnormally High Outside Air Temp.Svc Water Temp Reduced by Supplementing Cooling Source W/Svc Water Reservoir Makeup + (ML19338C697)
- ML19338C698 + (ML19338C698)
- ML19338C700 + (ML19338C700)
- ML19338C701 + (ML19338C701)
- ML19338C704 + (ML19338C704)
- ML19338C705 + (ML19338C705)
- AECM-80-185, Final Deficiency Rept:On 800228,132 Cables Damaged Under Reactor Pressure Vessel During Installation of Control Rod Drive Assembly.Caused by Inadequate Protection of Previously Installed Cables.Cables Repaired & Replaced + (ML19338C706)
- ML19338C707 + (ML19338C707)
- ML19338C708 + (ML19338C708)
- ML19338C709 + (ML19338C709)
- ML19338C711 + (ML19338C711)
- ML19338C714 + (ML19338C714)
- ML19338C715 + (ML19338C715)
- ML19338C716 + (ML19338C716)
- NUREG/CR-1380, Forwards Fuel Failures in Commerical Nuclear Power Reactors. Rept to Be Ref 3 to NUREG/CR-1380 (PNL3325) + (ML19338C717)
- ML19338C719 + (ML19338C719)
- ML19338C720 + (ML19338C720)