Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19323B433 + (ML19323B433)
- 05000309/LER-1980-010-03, /03L-0:on 800408,during Routine Surveillance Test of Auxiliary Feedwater Pump P-25A,small Amount of Oil Was Discharged from Pump Thrust Bearing.Cause Unknown.Personnel Have Been Instructed to Be Alert for Repetition of Event + (ML19323B434)
- ML19323B435 + (ML19323B435)
- 05000029/LER-1980-010, Forwards LER 80-010/03L-0 + (ML19323B436)
- ML19323B438 + (ML19323B438)
- 05000029/LER-1980-010-03, /03L-0:on 800406,during Maint Outage in Mode 5, Fire Detection Sys Became Inoperable Due to Loss of Voltage. Caused by Loose Wiring Connections in Power Supply.Wiring Connectors Were Replaced.All Connectors Were Tightened + (ML19323B439)
- ML19323B440 + (ML19323B440)
- ML19323B441 + (ML19323B441)
- ML19323B442 + (ML19323B442)
- 05000348/LER-1980-026-03, /03L-0:on 800405,erroneous Temp Change Alarm Was Received.Upon investigation,lead-lag Card in Circuit Found to Have Unstable Output.Cause unstated.Lead-lag Card Replaced + (ML19323B443)
- ML19323B444 + (ML19323B444)
- 05000348/LER-1980-027-03, /03L-0:on 800408,during Surveillance Test,Turbine First Stage Pressure Bistable PB447E Found to Trip,At Value Less than Tech Spec 3.3.2.1 Limit.Caused by Instrument Setpoint Drift.Loop Power Supply Card Adjusted + (ML19323B445)
- 05000313/LER-1980-013, Forwards LER 80-013/03L-0 + (ML19323B446)
- ML19323B447 + (ML19323B447)
- 05000313/LER-1980-013-03, /03L-0:on 800407,during Reactor Trip of Offsite Power,High Pressure Injection Was Manually Initiated & CV-1227 High Pressure Injection Valve,Loop B Failed to Open on Demand.Caused by Stuck Engaging Lever + (ML19323B448)
- 05000346/LER-1980-034, Forwards LER 80-034/03L-0 + (ML19323B449)
- ML19323B450 + (ML19323B450)
- ML19323B451 + (ML19323B451)
- 05000346/LER-1980-034-03, /03L-0:on 800411,during Auxiliary Feed Pump Instrumentation Calibr Test,Turbine 1 Steam Inlet Pressure Switch PSL-106B Actuated at Pressure Above Setpoint.Caused by Failure of Static O-ring Pressure Switch + (ML19323B452)
- 05000259/LER-1980-030, Forwards LER 80-030/03L-0 + (ML19323B453)
- ML19323B454 + (ML19323B454)
- 05000259/LER-1980-030-03, /03L-0:on 800406,during Normal Operation,Hpci Steam Line Space High Temp Switch TS-73-2A Operated Incorrectly During SI 4.2.B-37.Caused by Installation of Wrong Type Switch.Switch Replaced & Tech Specs Revised + (ML19323B455)
- ML19323B456 + (ML19323B456)
- ML19323B457 + (ML19323B457)
- ML19323B458 + (ML19323B458)
- ML19323B459 + (ML19323B459)
- ML19323B460 + (ML19323B460)
- ML19323B461 + (ML19323B461)
- ML19323B463 + (ML19323B463)
- ML19323B464 + (ML19323B464)
- ML19323B465 + (ML19323B465)
- ML19323B466 + (ML19323B466)
- ML19323B467 + (ML19323B467)
- ML19323B469 + (ML19323B469)
- ML19323B470 + (ML19323B470)
- IR 05000367/1980001 + (ML19323B471)
- 05000312/LER-1978-001, Responds to NRC Expressing Concern That 780320 Transient,Reported as LER 78-1,could Have Led to Results as Serious as Tmi.Operator Recognized That once-through Steam Generators Were Dry & Therefore Admitted Main Feedwater + (ML19323B472)
- ML19323B473 + (ML19323B473)
- 05000325/LER-1980-035, Forwards LER 80-035/03L-0 + (ML19323B474)
- ML19323B475 + (ML19323B475)
- ML19323B476 + (ML19323B476)
- ML19323B477 + (ML19323B477)
- ML19323B478 + (ML19323B478)
- 05000325/LER-1980-035-03, /03L-0:on 800407,while Performing Reactor Low Water Level 1 Channel Calibr,Switch 1 of 1-B21-LTS-N017B&C Was Out of Tolerance.Caused by Instrument Drift.Instruments Were Calibr & Returned to Svc.Plant Mod Has Been Written + (ML19323B479)
- 05000346/LER-1980-035, Forwards LER 80-035/O3L-0 + (ML19323B480)
- ML19323B481 + (ML19323B481)
- ML19323B482 + (ML19323B482)
- 05000346/LER-1980-035-03, /03L-0:on 800410,while Attempting to Switch from Decay Heat Removal Train 1 to Train 2,cooler 2 Outlet Valve Would Not Open.Caused by Malfunctioning of Valve Operator Radial Arm.Radial Arm Was Readjusted + (ML19323B483)
- 05000029/LER-1980-011, Forwards LER 80-011/03L-0 + (ML19323B484)
- ML19323B486 + (ML19323B486)
- 05000029/LER-1980-011-03, /03L-0:on 800407,during Maint Outage in Mode 5, Voltage Indication Lost for Fire Detection Sys.Caused by Failure of Voltage Indicating Light.Fire Patrol Established Until Sys Returned to Svc.Light Was Replaced + (ML19323B487)