Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000338/LER-1979-009-03, /03L-0 on 790212:during Normal Operation,Snubber Support for C Steam Generator Atmosphere Discharge Line Found Damaged.Caused by Use of Support as Anchor for Chain Fall.Support Replaced + (ML19305A332)
- ML19305A333 + (ML19305A333)
- 05000029/LER-1979-004, Forwards LER 79-004/03L-0 + (ML19305A334)
- 05000029/LER-1979-004-03, /03L-0 on 790206:Rod 6 Position Indicating Lights at 84,87 & 90 Inches Were Not Lit.Caused by Loose & Dirty Terminal Contact Surfaces.Contact Surfaces Cleaned & Tightened + (ML19305A336)
- ML19305A337 + (ML19305A337)
- 05000313/LER-1979-002, Forwards LER 79-002/01T-0 + (ML19305A339)
- ML19305A341 + (ML19305A341)
- 05000313/LER-1979-002-01, /01T-0 on 790205:during Startup,Nuclear Instrumentation Was Not Calibr as Required by Tech Spec 4.1, Table 4.1-1.Caused by Personnel Error.Occurrence Discussed W/Shift + (ML19305A342)
- ML19305A343 + (ML19305A343)
- ML19305A345 + (ML19305A345)
- ML19305A347 + (ML19305A347)
- ML19305A349 + (ML19305A349)
- ML19305A350 + (ML19305A350)
- ML19305A351 + (ML19305A351)
- ML19305A352 + (ML19305A352)
- ML19305A353 + (ML19305A353)
- 05000366/LER-1979-025, Forwards LER 79-025/01T-0 + (ML19305A354)
- ML19305A355 + (ML19305A355)
- IR 05000329/1978019 + (ML19305A356)
- ML19305A357 + (ML19305A357)
- ML19305A358 + (ML19305A358)
- 05000366/LER-1979-025-01, /01T-0 on 790223:upper & Lower Clevis Pins of Torus Vent Header Support Columns Were Displaced.Caused by Vibration.Design Change Issued & Is Being Implemented to Weld Caps to Clevis + (ML19305A359)
- ML19305A360 + (ML19305A360)
- ML19305A361 + (ML19305A361)
- ML19305A365 + (ML19305A365)
- ML19305A367 + (ML19305A367)
- 05000312/LER-1979-002-03, /03L-0:on 790205,redundant Unit A-500C Failed to Start,During Test of Reactor Bldg Emergency Cooler.Caused by Improperly Set Overcurrent Relay.Relay Reset, & Unit Retested & Declared Operable + (ML19305A368)
- ML19305A369 + (ML19305A369)
- ML19305A370 + (ML19305A370)
- ML19305A371 + (ML19305A371)
- ML19305A372 + (ML19305A372)
- ML19305A373 + (ML19305A373)
- ML19305A375 + (ML19305A375)
- ML19305A376 + (ML19305A376)
- ML19305A377 + (ML19305A377)
- ML19305A379 + (ML19305A379)
- ML19305A380 + (ML19305A380)
- ML19305A381 + (ML19305A381)
- IR 05000312/1978023 + (ML19305A382)
- ML19305A389 + (ML19305A389)
- ML19305A390 + (ML19305A390)
- ML19305A391 + (ML19305A391)
- ML19305A392 + (ML19305A392)
- ML19305A393 + (ML19305A393)
- ML19305A394 + (ML19305A394)
- IR 05000289/1979005 + (ML19305A396)
- ML19305A397 + (ML19305A397)
- ML19305A398 + (ML19305A398)
- ML19305A399 + (ML19305A399)
- ML19305A400 + (ML19305A400)
- ML19305A401 + (ML19305A401)