- ML19273B924 + (ML19273B924)
- ML19273B925 + (ML19273B925)
- ML19273B926 + (ML19273B926)
- ML19273B927 + (ML19273B927)
- 05000338/LER-1979-054, Forwards LER 79-054/03L-0 + (ML19273B928)
- ML19273B929 + (ML19273B929)
- 05000338/LER-1979-054-03, /03L-0 on 790513:charging Pump Removed from Svc to Repair Crack Inlet Piping.Caused by Bad Weld at Base of Vent Line.Crack Ground Out & Rewelded + (ML19273B930)
- 05000346/LER-1979-060, Forwards LER 79-060/03L-0 + (ML19273B931)
- ML19273B932 + (ML19273B932)
- 05000346/LER-1979-060-03, /03L-0 on 790519:fire Barrier Removed to Allow Removal of Hydraulic Snubber,But Continuous Fire Watch Was Not Established.Caused by Faulty Procedure.Mod Made to Hydraulic Snubber Testing Procedure + (ML19273B933)
- 05000346/LER-1979-059, Forwards LER 79-059/03L-0 + (ML19273B934)
- ML19273B935 + (ML19273B935)
- 05000346/LER-1979-059-03, /03L-0 on 790517:unsealed Hole Discovered in Fire Barrier Floor.Caused by Uncompleted Survey of Work Items.Gap Sealed & Training Meeting Held W/Maint & Const Supervisors + (ML19273B936)
- 05000312/LER-1979-005, Forwards LER 79-005/03L-0 + (ML19273B937)
- ML19273B939 + (ML19273B939)
- ML19273B940 + (ML19273B940)
- 05000312/LER-1979-005-03, /03L-0 on 790509:two Inaccessible Safety Sys Hydraulic Snubbers Were Inoperable.Cause Unknown.One Snubber Rebuilt & Tested;Other Snubber Refilled + (ML19273B941)
- 05000333/LER-1979-028, Forwards LER 79-028/03L-0 + (ML19273B942)
- ML19273B943 + (ML19273B943)
- ML19273B944 + (ML19273B944)
- 05000333/LER-1979-028-03, /03L-0 on 790517:during Cold Shutdown,Level Instrument of Carbon Dioxide Storage Sys Was Out of Calibr. Caused by Procedural Error.Instrument Racalibr & Satisfactorily Tested + (ML19273B945)
- 05000368/LER-1979-035-03, /03L-0 on 790514:during Mode 3,emergency Feedwater Flow Control Valve Failed to Open or Respond to Demand Signal.Similar to LERs 50-368/78-028 & 50-368/78-009. Caused by Pressure Switch Malfunction.Switch Repaired + (ML19273B946)
- ML19273B947 + (ML19273B947)
- ML19273B948 + (ML19273B948)
- 05000333/LER-1979-030, Forwards LER 79-030/03L-0 + (ML19273B950)
- ML19273B951 + (ML19273B951)
- 05000368/LER-1979-036-03, /03L-0 on 790514:during Mode 3,emergency Feedwater Supply Valve Did Not Meet Required Limiting Value of Stroke Time.Caused by Tripper Bar Pickup Out of Adjustment & Low Oil Level.Repairs Made + (ML19273B952)
- ML19273B953 + (ML19273B953)
- 05000333/LER-1979-030-03, /03L-0 on 790518:during Cold Shutdown,Test Point Was Discovered in Error.Caused by Deviations in Conduction of Surveillance Test Procedures F-ISP-89.Procedure Was Immediately Correted & Surveillance Complete + (ML19273B954)
- ML19273B955 + (ML19273B955)
- ML19273B957 + (ML19273B957)
- ML19273B958 + (ML19273B958)
- ML19273B961 + (ML19273B961)
- ML19273B962 + (ML19273B962)
- ML19273B963 + (ML19273B963)
- ML19273B965 + (ML19273B965)
- 05000313/LER-1979-005, Forwards LER 79-005/03L-0 + (ML19273B967)
- ML19273B968 + (ML19273B968)
- ML19273B969 + (ML19273B969)
- ML19273B970 + (ML19273B970)
- ML19273B972 + (ML19273B972)
- ML19273B973 + (ML19273B973)
- 05000313/LER-1979-005-03, /03L-0 on 790524:during Leak Rate Testing, Penetration V-1 Leaked in Excess of 50,000 Cubic Cm/Minute. Caused by Buildup of Boric Acid Crystals on Valve Seating Surfaces.Repairs Made & Penetrations Retested + (ML19273B974)
- ML19273B975 + (ML19273B975)
- ML19273B976 + (ML19273B976)
- ML19273B978 + (ML19273B978)
- ML19273B979 + (ML19273B979)
- ML19273B981 + (ML19273B981)
- ML19273B983 + (ML19273B983)
- ML19273B984 + (ML19273B984)
- ML19273B985 + (ML19273B985)