Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19261F217 + (ML19261F217)
- ML19261F218 + (ML19261F218)
- ML19261F219 + (ML19261F219)
- ML19261F220 + (ML19261F220)
- ML19261F222 + (ML19261F222)
- ML19261F223 + (ML19261F223)
- 05000289/LER-1978-013-01, /01T-0:on 780413,B&W Informed Util That Small Break on Reactor Coolant Pump Discharge Had Not Been Analyzed in Fsar.Procedures to Be Revised & Operators to Be Trained in Response to Small Break LOCA + (ML19261F224)
- ML19261F225 + (ML19261F225)
- ML19261F226 + (ML19261F226)
- 05000289/LER-1978-012, Forwards LER 78-012/03L-0 + (ML19261F227)
- ML19261F228 + (ML19261F228)
- ML19261F229 + (ML19261F229)
- ML19261F230 + (ML19261F230)
- ML19261F231 + (ML19261F231)
- 05000289/LER-1978-012-03, /03L-0:on 780406,during Functional Tests,One Snubber DHH-187 Would Not Lock Up Upon Compression.Cause Undetermined.Valve Block Replaced & Satisfactory Test Made + (ML19261F232)
- ML19261F233 + (ML19261F233)
- ML19261F234 + (ML19261F234)
- 05000289/LER-1978-011-03, /03L-0:on 780318,snubber MS-201 Found W/No Fluid in Reservoir.Caused by Pinched Rod Wiper Seal + (ML19261F235)
- 05000289/LER-1978-010, Forwards LER 78-010/01T-0 + (ML19261F236)
- ML19261F237 + (ML19261F237)
- ML19261F238 + (ML19261F238)
- ML19261F239 + (ML19261F239)
- ML19261F240 + (ML19261F240)
- ML19261F241 + (ML19261F241)
- 05000289/LER-1978-010-01, /01T-0:on 780318,during Emergency Sequence & Power Transfer test,1A & 1C Makeup Pumps Tripped When Transferring to Onsite Source Due to Malfunctioning Time Delay Relay & Diesel Generators Failed to Start Due to Pressure Swit + (ML19261F242)
- ML19261F243 + (ML19261F243)
- 05000289/LER-1978-007, Forwards LER 78-007/03L-0 + (ML19261F244)
- ML19261F245 + (ML19261F245)
- ML19261F246 + (ML19261F246)
- ML19261F247 + (ML19261F247)
- 05000289/LER-1978-007-03, /03L-0:on 780128,while at 50% of Full Power,Incore Quadrant Power Tilt Limit Exceeded.Transient Caused by Transient Power Operations & Maneuvering to all-rods-out Configuration.Xenon Burned Out & Tilt Returned to Limits + (ML19261F248)
- ML19261F249 + (ML19261F249)
- ML19261F250 + (ML19261F250)
- ML19261F251 + (ML19261F251)
- ML19261F252 + (ML19261F252)
- ML19261F253 + (ML19261F253)
- 05000289/LER-1978-006, Forwards LER 78-006/03L-0 + (ML19261F254)
- ML19261F255 + (ML19261F255)
- ML19261F256 + (ML19261F256)
- 05000289/LER-1978-006-03, /03L-0:on 780124,during Normal Operation,Reactor Coolant Sample Isolation Valve CA-V13 Failed to Close When Actuated by Remote Signal.Caused by Valve Stem Thread Wear. Containment Isolation Valve CA-V2 Closed + (ML19261F257)
- ML19261F259 + (ML19261F259)
- 05000289/LER-1978-003, Forwards LER 78-003/03L-0 + (ML19261F261)
- ML19261F262 + (ML19261F262)
- 05000289/LER-1978-003-03, /03L-0:on 780112,emergency Diesel Generator 1B Failed to Start on Simulated Test Signal During Procedure SP1305-5.2.Caused by Drifting Oil Pressure Limit Switch. Setting Adjusted,New Limit Switch Ordered + (ML19261F263)
- 05000289/LER-1978-004, Forwards LER 78-004/03L-0 + (ML19261F264)
- ML19261F265 + (ML19261F265)
- ML19261F266 + (ML19261F266)
- 05000289/LER-1978-004-03, /03L-0:on 780117,while Closing Valve MU-V74A,22 Gallon Per Minute Packing Gland Leak Developed.Caused by Worn Packing in Valve.Valve Placed on Backseat.Packing Replaced 780118 + (ML19261F267)
- ML19261F268 + (ML19261F268)
- ML19261F269 + (ML19261F269)
- 05000289/LER-1978-005, Forwards LER 78-005/01T-0 + (ML19261F270)