ML19261F218

From kanterella
Jump to navigation Jump to search
Abnormal Occurrence 50-289/74-07:on 740604,outdated Procedures Found Used During Plant Heatup & Sys Operation. Caused by Personnel Negligence.Checklists & Procedure Replaced W/Current Copies.Responsibility Defined
ML19261F218
Person / Time
Site: Crane 
Issue date: 06/14/1974
From: Arnold R
METROPOLITAN EDISON CO.
To:
References
GQL-0084, GQL-84, NUDOCS 7910250638
Download: ML19261F218 (4)


Text

,AFC DI F**UTION FOR PART 50 DOCZET MAT L-5490 (TEMPORARY FO?li)

CONTROL NO:

FILE:

FROM:

DATE OF DCC DATE REC'D LTR TWX RPT OTHER Met'ropoli. tan Edison Company Reading, Penn. 19603 Mr. R.C. Arnold 6-14-74 6-18-74 X

TO:

ORIG CC OTHi.R SENT AEC PDR XXX AEC 1 siened CLASS UNCLASS PROP IhTO INPUT NO CYS REC'D DOCKET NO:

XXX 1

50-289 DESCRIPTION:

ENCLOSURES:

Ltr reporting an abnormal occurrence at the Three N ' e Island Unit #1...concerning

' ' ~ ~

Inadequate Administrative Control of Valve and Startup Checklists and Operational Procedures...

PLANT NAME:

Three Mile Island Unit #1

[C FOR AC ION /INFORMATION 6-I9-;4

.19 BUTLER (L)

SCHRENCER(L)

ZIDiANN(L)

REGAN(E)

W/ Copies W/7 Copies W/ Copies W/ Copies CLARK (L)

STOLZ(L)

DICKER (E)

W/ Copies W/ Copies W/ Copies W/ Copies PARR(L)

VASSALLO(L)

KNIGHION(E)

'.!/

C ;ic:

"/ C:pic:

U/ C:pic:

9/ C pic:

KNIEL(L)

PURPLE (L)

YOUNGBLOOD(E)

W/ Copies W/ Copies W/ Copies W/ Copies INTERNAL DISTRIBUTICN F

'G FILJ TECH RWIE*J DENTON A/T IND 4C Ra

'rENDRIE GRIMES LIC ASST BRAITMA'1

~/0GC, ROOM P-506A SCHROEDER GAMMILL DIGCS (L)

SALTZMAN p4fUNTZING/ STAFF

/MACCARY KASINER B. WRT GEARIN (L)

/ CASE

/ KNIGHT BALLARD

/ t0ULBOUR'iE (L)

PLANS GIR!BUSSO

./PAWLICKI SPANGLER Lgg (L)

MCDONALD BOYD

/SHAO MAIGRET (L)

DUBE w/ input

/ MOORE (L)(57R)

/STELLO ENVIRO REED (E)

CHAPMAN DEYOUNG(L)(?WR)

/EOUSTON MULLER NO SERVICE (L)

SKOVHOLT (L)

/NOVAK DICKER C. MILES SHEPPARD (L)

SLATER (E)

AECR COLLER(L)

/ ROSS KNIGHTON P. COLLINS

/IPPOLITO YOUEGBLOOD "EIS net T SMITH (L)

D$NISE TEDESCO REGAN TEETS (L)

/ REC OPR

/LONG PROJECT LDR WADE (E)

/AOR FIR FILE & REGION (3)

/LAINAS WILLLAMS (E)

D. THCMPSON (2)

/ MORRIS

/ ENAR0YA HARLESS WILSON (L)

L

/STEELE VOLIFER 1dkk \\U

/IMA EXTE3NAL uiSTRI3UTICN V1 - LOCAL PDR

'Harrisburw. P n

[

  1. 1 - TIC (ABERNAThT)

(1)(2)(10) NATIONAL LAB'S 1-PDR-SAN /LA/SY

  1. 1 - NSIC(EUCEA';AN) 1-ASL3P(E/W 31dg,R= 329) 1-LIBRARIXi 1 - ASL3 1-W. PENNINGTON, Rm E-201 GT BRCOKHAVEN NAT. LA3 1 - P. R. DAVIS (AEROJET NUCLEAR) 1-CONSULTANT' S 1-AGMED(Ruth Guss n.i

/16 - CYS ACRS F'tatMe Sent to Goulbourne NEWMARK/ 3L'CE/AGBABIMI RM-B- 12 . OT.

1-GERALD ULRIKSON...CRFL l-RD.. MULLER..F-300 GT 6-19-74 1-3 &.M SWINE 3RCAD, En E-201 GT 7910250 f 3 g 3

l$m$u.I 7A..'. 's h

v -.

me 7:n **xons METROPOLITAN EDISON COMPANY DOCT CFFICE BOX 542 PEAclNG, PENNSYLVANI A 19603 TELEPwCNE 215 - 929 3 01 June ik, 197h GQL OC8h

, f. -, 1.. ' s7,.N

?

f %/,,,, p ;., N b.

i l.'./

s, ?, ' ' ' /.

G gf. A.' / if LILl l I'y (!

(.c'W '.' r

\\

(]

Jygij U 734 31i f

Ica Y?

Director Directorate of Licensing

,/c MI', AU.,,,NO'.-;_,

g,,, ' ? a;,.

fj i]-

U. S. Atcmic Energy Cen=issicr---

y Washington, D. C.

205h5

@6

'.l 1

k.&, ;"nf; i J.

n,..,,... t f,/

u-.

._ a w t si:: a g

Dear Sir:

\\

CGCLU CL W N

6

. O '/

X s.:. s. -

y,

/y h

Cperating i'dtnseGD

.-50 Dceket No. Su-cvy In acecrdance with the Technical Specificatiens fcr the Three Mile Island Nuclear Statien, Unit 1, we are reporting the folleving abncrnal occur-rence:

(1)

Repcrt Nu=ber: A0 50-289/Th-7 (2a) Report Date: June 14, 197h (2b) Occurrence Date: June h, 197h (3)

Facility: Three Mile Island Nuclear Generating Statien, Unit 1 (h)

Identificatien of Occurrence:

Title:

Inadequate Administrative Centrol of Valve and Startup Checklists and Cperational Precedures Type:

Viclation of Technical Specificaticns, paragraph 6.7.2a.5 which ecnstitutes an abncr=al occurrence as defined by the Technical Specificatiens, paragraph 1.8g, in that the inadequate Administrative Centrol of valve and startup checklists and cperaticnal procedures might have threatened to cause an unsafe condition in the operation of the plant.

(5)

Ccnditiens Prior to Occurrence: Hot shutdcyn, in preparation fcr initial criticality with plant parameters as follevs:

Pcver:

Core: 0 Elec: 0 RC Flev:

138 X 10 lb/hr j }))

"O

~

Directorate of Licensing June 14, 19Th RC Pressure: 2155 psig RC Te=p.:

532 F FRZR Level:

100" PRZR Temp.:

6h5 F (6)

Descriptien cf Occurrence: Cn June h, 197h, several cutdated valve and startup checklists from outdated procedures were fcund to have been used in the course of plant heatup, and, in ene case, an cut-dated procedure was used to operate a system. The cutdated check-lists and procedure were prc=ptly replaced with current ecpies.

A ccmparison of current and previcus editions was made and no unsafe ccnditicns were found to exist as a result of having used the outdated editiens.

(T)

Apparent Cause of Occurrence: Personnel, in that although a precedure exists which requires perscnnel using procedures er parts of procedures (which includes checklists) to ensure they are current, the cperaticns persennel involved in this incident did not ensure that the precedures they were using were the current editions.

Another cause which centributed to the cccurrence was trccedure in that responsibilities were not well enough defined regarding the maintaining of procedure files.

(8)

Analysis of Cecurrence: This cccurrence did not result in a threat to public health or safety in that no unsafe conditions were caused to exist.

(9)

Corrective Acticns:

!=nediate corrective actions were as described in the above analysis.

The Plant Operations Review Cc==ittee met promptly after the incident and recen= ended to the Station Superintendent thr.' :

a.

a cceplete audit be ccnducted of all precedure files, to include:

(1) replacing outdated precedures with current editions, (2) destroying extra copies of procedures and extra ecpies of parts cf procedures, and (3) conducting the audit en a periodic basis, and b.

a =emo be written to (1) define those individuals responsible fcr maintaining up-tc-date procedure files, and (2) reiterate to plant persennel the importance of assuring they use cnly current precedures.

l'481 178

Directorate of Licensing June IL, 197L The Station Superintendent concurred with PCRC's findings, the first audit has been conducted, and the menc has been written.

(10) Failure Data:

a.

Previcus failures: Uct Applicatie.

b.

Equipment identificaticn: Not Applicable.

Sincerely, R. C. ARNCLD Vice President-Generatien RCA; LNG:sh ec: Directorate of Regulatory Operations, Regicn 1 U. S. Atomic Energy Cen=ission 631 Esrk Avenue King of Prussia, Pennsylvania 19h06 File 20.1.1 77351 g81 179