ML19261F269

From kanterella
Jump to navigation Jump to search
Abnormal Occurrence 74-03:on 740520,during Normal Surveillance Testing,Diesel Engine Tripped on Low Lube Oil Pressure.Caused by Disconnection of Switches from Sensing Lines.Engine Repaired & Restored to Svc.Personnel Briefed
ML19261F269
Person / Time
Site: Crane 
Issue date: 05/30/1974
From: Arnold R
METROPOLITAN EDISON CO.
To:
References
NUDOCS 7910250710
Download: ML19261F269 (4)


Text

'

AEC L T

UTION FC1 PART 50 DOCKET W.

'~

(TEMPORARY FCD )

CONTROL NO:

4896

- f FILE:

A '/

FRCM:

DATE CF ECC DATE REC'D LTR 11D10 RPT OT:C R Metropolitan Edison Company Reading, Pa. 19603 5-30-74 6-3-74 X

R. C. Arnold TO:

ORIG CC OTHER SENT AEC PDR X D. L.

I signed SENT LOCAL PDRX CLASS UNCLASS PROP INFO INPUT NO CYS REC'D DOCKET NO:

XXX 1

50-289 DESCRIPTION:

ENC. OSURES :

Ler reporting abnormal occurrence A0-74-3 on 5-20-74, regarding inadequate administrative Control of Emergency Diesel Generator IB ACKNOWLEDGED Maintenance........

DO NOT REMOVE PLANT NAME: Three Mile Island Unit #1 FOR ACTION / INFO?l'_ATION 0-4-74 GC E'JTLER(L)

/CIMENCER(L)

ZIDi*NN(L)

REGAN(E)

W/ Copics W/ 7 Copies W/ Copies W/ Copies CLARK (L)

STOLZ(L)

DICKER (E)

W/ Copics W/ Copies W/ Copies W/ Copies PARR(L)

VASSALLO(L)

KNIGHTCN(E)

U/ C:pic:

n/ C:pi::

n/ C:pic:

n/ C:pic:

KNIEL(L)

PURPLE (L)

YOUNGBLOOD(E)

U/,Copias W/ Copies W/ Copies W/ Copies n

INTERNAL DISTRIBUTION

/fREG FU.F TECH REVIE'J DENTON A/T IND

/AEC PDR MENDRIE GRIMES LIC ASST BRAI'D'AN 4 GC, ROCM P-506A SCHRCEDER GAMMILL

,DICGS (L)

SALTDIAN J1 UNI 2ING/ STAFF 4.ACCARY KASTNER GEARIN (L)

B. HURT J ASE M IGHT BALLARD d OUL30UPJiE (L)

PLANS GIAMEUSSO A'AWLICKI SPANGLER LEE (L)

MCDONALD BOYD JHA0 LIGRET (L)

DUEE w/ Input J CORE (L)(3'iR)

.ATELLO ENVIRO REED (E)

DEYOUNG(L)(PWR)

JOUSTON MULLER O

SERVICE (L)

SKOVHOLT (L)

AIOVAK DICKER SHEPPARD (L)

C. MILES COLLER(L)

AOSS ICIIGHTON SMTER (E) p/ LECKER P. COLLINS JPPOLITO YOUNGBLOOD 33773 (t)

/EISENHUT DENI3E

/I'EDESCO REGAN TEETS (L)

JEG OPR

/,0NG PROJECT LDR WADE (E)

AOR FILE

' FILE & REGION (3)

  1. tAINAS WILLIAMS (E)

VD. THO WSC5 Q) vMORRIS 64 DIAR 0YA HARLESS WILSON (L) 1481 288

/STEELE

/OLU!IR m

EXS?liAL DIS 3ICUTICN Ed vi - LOCAL PDA uarrisbur2. Pa.

1-PDR-S!J:/LA 'NY {

d - TIC (A3ZRNATHY)

(1)(2)(10)-NATIONAL LA3'S 4 - NSIC(3UCLVIAN) 1-ASL3?(E/U 31c;,R:a 529) 1-GERALD LELLCT :C 1 - ASLB 1-W. PEN:;INGTon, R.. E-201 GT BRC0KI C U ti!. D.3 1 - P. R. DAVIS (AEROJET NUCLEAR) 1-CONSULTANT'S

' AC".ED ( Ru c - Gu 5 n r V16 - CYS ACRS FYYHTXE SENT TO LIC. ASST.

NE'OIAR'U BLDiE/AG31s3I AN EM-3-12'. c.T.

6-4-74 GotLBOURNE l-CERALD ULRIKSON... C'.U;L l-RD.. MULLER. 7-3C9 -

1-B & M SWINE 3 ROAD, Rm E-201 GT Tolosso 7m 3

~

Regutatory-Docket Hle Y

Cw

-Oh*;fYU n n na :c m METROPOLITAN EDISON COMPANY

,Cx pc cmCE 2']X 542 REAO:NG. PENNSYLVANI A 1960 N,

TELEPHcNE 215 - 9 9-2601 Q

t:

\\

/

ly, U.o 16r\\ 30, 197h m

J a,

y-

-i

.s f.r -

- * :/4 L ~ !

\\'.e

+

~ c.

( --

l:c y'G C.[ih*!

~'

ys t.

M"!

?/

Director

\\.9" Ni u N/

  • Q:

'?.

Directorate of Licensing Vo ; s N,]3 ~ '. 4,

'C' {

U. S. Atc=ic Energy Cec =ission % ( N '.'.} /

'4ashingten, D. C.

205h5

/04,.

24 0

<x y

Gentlemen:

Operating License DPR-50 Docket No. 50-289 In acecrdance with Technical Specificaticus for the Wee Mile Island Nuclear Staticn Unit 1, we are reporting the follevin6 abnor=al cccurrence:

(1)

Report Number: AC-Th-3 (2a) Report Date: May 30, 197h (2b) Occurrence Date: May 20, 19Th (3)

Facility: Three Mile Island Nuclear Generating Station, Unit 1 (h)

Identification of Occurrence:

Title:

Inadequate Administrative Centrc] of E=ergency Diesel Generater 13 Maintenance Type:

Violatien of Technical Specificaticns, paragraph 6.2 3, which constitutes an abncr=al occurrence as defined by the Technical Specificaticus, paragraph 1.8g, in that the inadequate Administrative Centrol of E=ergency Diesel Generator 13 Maintenance =ay have threatened to cause an unsafe condition in the cperaticn of the plant.

(5)

Conditions Prior to Occurrence: Ect shutdevn, with major plant parameters as follows:

Fover:

Cere: C Elec: 0 RC Flev:

10h x 1C #/hr. (3 R.C. Pu=ps)

)48j

}@}

RC Fressure: 2150 RC Temp.:

525 489d

[

Directorate of Licensing May 30, 197h PEZR Level:

120" PRZR Temp.:

6h6 F (6)

Description of Occurrence: At 1900 cn May 19, 197h, during ner=al surveillance testing of the 13 Energency Dicsel Generator, it was discovered that the diesel engine would start as required but would not continue to run because of a 1cv lube oil pressure signal.

The diesel engine tripped en low lube oil pressure because three diesel engine lube oil pressure switches were disconnected frc=

their sensing lines. Investigation by the Plant Operations Review Cc==ittee (PCRC) revealed that the pressure switches had been mistakenly left disecnnected by =aintenance persennel on May 18, 197h, and that the maintenance Laing perfer=ed en the diesel engine at that time was not being dcne in accordance with an approved =aintenance procedure as required by the Technical Speci-ficaticcs and Station Ad=inistrative Precedures.

(7)

Designation of Apparent Cause of Occurrence: Persennel (8)

Analysis of Occurrence: The Energency Diesel Generatcr 13 was incapable of perfor=ing its design function for a period of approxi-

=ately h8 hcurs. This did not result in a threat to public health or safety because under the plant ecnditions that existed at the ti=e of thu occurrence, the diesels were not required to be operable in accordance with Section 3 7 of Technical Specifications. Further-

=cre, had a condition existed that required the diesel generators to be operable, Technical Specificatiens per=1t one diesel generater to be inoperable for seven days.

(9)

Corrective Action: The Plant Operations Review Cc==ittee (PCRC)

=et prc=ptly after the incident and reccc= ended to the Plant Superintendent a.

a precedure to repair, test, and restere to service the Ener-gency Diesel Generater 13, and b.

that maintenance persennel involved in the incident be briefed en the i=portance of using approved procedures.

The Plant Superintendent concurred with PORC's recc==endations; the approved maintenance procedure was used to repair, test, 2nd restere to service Energency Diesel Generator 13; and =aintenance perscnnel were briefed on the i=pertance of using approved proce-dures.

In addition to the above acticas, the Statien Superintendent has instructed Statica F%nage=ent and Superviscry perscnnel to emphasize to these reporting to the= the i=pertance of perfer=ing vork in accordance with approved procedures.

{hb\\

. Directorate of Licensing May 30, 197L (10) Failure Data: Not Applicable.

Sincerely, ROBER'2 C. AP5CLD Vice President-Generatien RCA:DNG:sh cc: Directorate of Regulatory Operations, Region 1 U. S. Atemic Energy Cen=ission 631 Park Avenue Kirc of Prussia, Pennsylvania 19h06

}'

\\