Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- ML19260D916 + (ML19260D916)
- ML19260D918 + (ML19260D918)
- ML19260D919 + (ML19260D919)
- ML19260D920 + (ML19260D920)
- ML19260D921 + (ML19260D921)
- ML19260D922 + (ML19260D922)
- ML19260D923 + (ML19260D923)
- ML19260D924 + (ML19260D924)
- ML19260D925 + (ML19260D925)
- ML19260D927 + (ML19260D927)
- ML19260D930 + (ML19260D930)
- 05000285/LER-1980-004, Forwards LER 80-004/01T-0 + (ML19260D931)
- ML19260D932 + (ML19260D932)
- ML19260D933 + (ML19260D933)
- ML19260D934 + (ML19260D934)
- ML19260D935 + (ML19260D935)
- ML19260D936 + (ML19260D936)
- ML19260D937 + (ML19260D937)
- ML19260D938 + (ML19260D938)
- ML19260D939 + (ML19260D939)
- ML19260D940 + (ML19260D940)
- ML19260D941 + (ML19260D941)
- ML19260D942 + (ML19260D942)
- ML19260D943 + (ML19260D943)
- ML19260D945 + (ML19260D945)
- 05000280/LER-1980-005-03, /03L-0:on 800120,while Conducting PT 27D Heat Tracing Sys,Discovered That Circuit 17A Panel 9 Was Inoperative.Caused by Thermostat Failure.Maint Rept Initiated.Defective Thermostat Replaced + (ML19260D948)
- 05000309/LER-1980-002, Forwards LER 80-002/03L-0 + (ML19260D949)
- 05000309/LER-1980-002-03, /03L-0:on 800108,during Surveillance Testing of Containment Personnel hatch,O-ring Seal on Inner Door Found Leaking excessively.O-rings Replaced + (ML19260D951)
- ML19260D956 + (ML19260D956)
- 05000280/LER-1980-006-03, /03L-0:on 800115,during Routine Surveillance of Liquid Waste Release,Discovered That Unsampled Waste from Tank 5A Was Being Pumped to Tank 5B.Caused by Inadvertent Operation of Transfer Pump.Waste Release Terminated + (ML19260D957)
- ML19260D958 + (ML19260D958)
- ML19260D959 + (ML19260D959)
- ML19260D960 + (ML19260D960)
- 05000280/LER-1980-007-03, /03L-0:on 800116,during Normal Operation,Heat Tracing Circuit 4 on Line 1-CH-56-152,boric Acid Supply to Blender Failed.Caused by Water Penetration of Heat Tracing Tape.Tape Replaced W/Higher Water Resistant Tape + (ML19260D961)
- 05000267/LER-1980-005, Forwards LER 80-005/03L-0 + (ML19260D962)
- ML19260D963 + (ML19260D963)
- 05000338/LER-1980-015, Forwards LER 80-015/03L-0 + (ML19260D964)
- ML19260D965 + (ML19260D965)
- ML19260D966 + (ML19260D966)
- ML19260D967 + (ML19260D967)
- ML19260D968 + (ML19260D968)
- 05000338/LER-1980-015-03, /03L-0:on 800116,during Reactor Physics Testing Following Refueling Outage,Reactor Was Critical W/Rcs Tavg Under 541 F.Caused by Cooldown While Attempting to Maintain RCS Temp During Testing.Heat Release Valve Closed + (ML19260D969)
- ML19260D970 + (ML19260D970)
- 05000318/LER-1980-002, Forwards LER 80-002/03L-0 + (ML19260D971)
- ML19260D972 + (ML19260D972)
- 05000267/LER-1980-005-03, /03L-0:on 800111,during Release from Gaseous Waste Holdup Sys,Recorder Did Not Function Properly.Caused by Bad Bull Drive Gear & Clutch Assembly.Parts Replaced & Recorder Returned to Operation + (ML19260D973)
- ML19260D974 + (ML19260D974)
- 05000318/LER-1980-002-03, /03L-0:on 800107,refueling Water Tank Narrow Range Level Indicator Was in Alarm W/Low Level,But Instrument Did Not Indicate Alarm Conditions.Caused by Faulty Indicator Alarm light-emitting Diode.Diode Replaced + (ML19260D975)
- ML19260D976 + (ML19260D976)
- 05000285/LER-1980-004-01, /01T-0:on 800126,while Fire Barrier Inside Empty Breaker Cubicle Was Degraded to Pull in New Cabling,Fire Watch Was Not Maintained Continuously.Caused by Fire Watch Not Receiving Accurate Info on Status of Barrier + (ML19260D977)
- 05000272/LER-1980-002-03, /03L-0:on 800104,discovered That Functional Tests of Power Range Neutron Flux Low Trip Setpoint When Greater than 25% Power Had Not Been Performed Since 1976.Caused by Lack of Procedures for Tests + (ML19260D978)