- 05000271/LER-1979-034-01, /01P-0:on 791211,during Seismic Analyses of Seismic Class 1 Pipe Supports,Discovered That Pipe Supports in Portion of Two Sys May Not Support Seismic Loads.Caused by Incorrect Design or Application of Supports + (ML19256F318)
- ML19256F319 + (ML19256F319)
- ML19256F320 + (ML19256F320)
- 05000324/LER-1979-100, Forwards LER 79-100/03L-0 + (ML19256F321)
- ML19256F322 + (ML19256F322)
- ML19256F323 + (ML19256F323)
- 05000324/LER-1979-100-03, /03L-0:on 791120,during Normal Reactor Startup, Full Out Indication Not Received by Reactor Sequence Control Sys from Control Rod 06-27.Caused by Defective Optical Isolator.Isolator Replaced + (ML19256F324)
- ML19256F325 + (ML19256F325)
- ML19256F326 + (ML19256F326)
- ML19256F327 + (ML19256F327)
- 05000278/LER-1979-035-03, /03L-0:on 791102,during Insp of Traveling in Core Probe Sys,Shear Valves in Guide Tube Assemblies Detected Installed Backwards.Caused by Facility Const Error.Five Shear Valves Removed & Properly Reinstalled + (ML19256F328)
- ML19256F329 + (ML19256F329)
- ML19256F330 + (ML19256F330)
- ML19256F331 + (ML19256F331)
- ML19256F332 + (ML19256F332)
- ML19256F333 + (ML19256F333)
- ML19256F334 + (ML19256F334)
- ML19256F335 + (ML19256F335)
- ML19256F336 + (ML19256F336)
- ML19256F337 + (ML19256F337)
- 05000324/LER-1979-096, Forwards LER 79-096/03L-0 + (ML19256F338)
- ML19256F339 + (ML19256F339)
- ML19256F340 + (ML19256F340)
- 05000324/LER-1979-096-03, /03L-0:on 791115,during Reactor Low Pressure Channel Calibr & Function Test,Switches 1 & 2 of 2-B21-PS-N021D Were Out of Tolerance.Caused by Loose Actuating Cam.Cam Set Screw Tightened & Instrument Calibr + (ML19256F342)
- ML19256F343 + (ML19256F343)
- ML19256F344 + (ML19256F344)
- ML19256F345 + (ML19256F345)
- 05000278/LER-1979-038, Forwards LER 79-038/01T-0 + (ML19256F346)
- ML19256F347 + (ML19256F347)
- ML19256F348 + (ML19256F348)
- ML19256F349 + (ML19256F349)
- ML19256F350 + (ML19256F350)
- 05000278/LER-1979-038-01, /01T-0:on 791120,during Review of Surveillance Test,Two MSIVs in a Steamline Closed in Times Shorter than Specified in Tech Specs.Caused by Operator Not Recognizing Fast MSIV Closure Time.Operator Procedure Revised + (ML19256F351)
- ML19256F352 + (ML19256F352)
- ML19256F353 + (ML19256F353)
- ML19256F357 + (ML19256F357)
- ML19256F358 + (ML19256F358)
- ML19256F362 + (ML19256F362)
- ML19256F363 + (ML19256F363)
- ML19256F364 + (ML19256F364)
- ML19256F365 + (ML19256F365)
- ML19256F366 + (ML19256F366)
- ML19256F367 + (ML19256F367)
- ML19256F368 + (ML19256F368)
- ML19256F369 + (ML19256F369)
- ML19256F370 + (ML19256F370)
- ML19256F371 + (ML19256F371)
- ML19256F372 + (ML19256F372)
- ML19256F373 + (ML19256F373)
- ML19256F374 + (ML19256F374)
- ML19256F375 + (ML19256F375)