- 05000333/LER-1979-093-03, /03X-1:on 791021,during Normal Operation,Routine Computer Printout Indicated Core Max Fraction of Limiting Power Density Was 1.003 Over Tech Spec Limit.Power Reduced 2%.Control Rod Pattern Adjusted.Cause Not Reported + (ML19253C324)
- ML19253C325 + (ML19253C325)
- 05000302/LER-1979-104-03, /03L-0:on 791028,remote Shutdown Indicator for Decay Heat Cooler Outlet Temp DH-40-TI Was Inoperable.Caused by Loose Precision Resistor Assembly.Resistor Bridge Assembly Tightened & DH-40-TI Returned to Svc + (ML19253C326)
- ML19253C327 + (ML19253C327)
- 05000265/LER-1979-024-03, /03L-0:on 791025,vacuum Breaker AO 2-1601-20B Failed to Open During Calibr & Functional Test.Caused by Component Failure.Solenoid Valve 2-1601-50B Rebuilt 791025 + (ML19253C328)
- ML19253C329 + (ML19253C329)
- 05000324/LER-1979-089, Forwards LER 79-089/03L-0 + (ML19253C330)
- ML19253C331 + (ML19253C331)
- 05000324/LER-1979-089-03, /03L-0:on 791104,during drywell-to-torus Vacuum Breaker Test,Close Indication Could Not Be Obtained on Valve 2-CAC-X18D.Caused by Defective Switch.Lead Replaced & Switch to Be Repaired in 1980 Refueling Outage + (ML19253C332)
- 05000265/LER-1979-026-03, /03L-0:on 791022,during Turbine First Stage Low Pressure Calibr Procedure Qis 55-1,pressure Switch PS-2-504C Tripped Above Tech Spec Limit.Caused by Instrument Set Point Drift.Pressure Switch Recalibr + (ML19253C333)
- 05000302/LER-1979-103, Forwards LER 79-103/03L-0 + (ML19253C334)
- ML19253C335 + (ML19253C335)
- 05000265/LER-1979-025, Forwards LER 79-025/03L-0 + (ML19253C336)
- ML19253C337 + (ML19253C337)
- 05000302/LER-1979-103-03, /03L-0:on 791024,makeup Pump MUP-1B Discharge Line Vent Valve MUV-291 Found Leaking.Caused by Cyclic Vibration Fatigue.Makeup Pump Returned to Svc.Engineering Evaluation Underway + (ML19253C338)
- 05000295/LER-1979-087, Forwards LER 79-087/03L-0 + (ML19253C339)
- 05000295/LER-1979-087-03, /03L-0:on 791027,containment Vent Particulate Radiation Monitor 1RE-0011 Failed Low During Refueling. Caused by Loose Contacts on Low Flow Trip Relay.Female Pins in Socket of Relay Adjusted + (ML19253C341)
- 05000324/LER-1979-090, Forwards LER 79-090/03L-0 + (ML19253C342)
- ML19253C343 + (ML19253C343)
- ML19253C344 + (ML19253C344)
- 05000324/LER-1979-090-03, /03L-0:on 791031,containment Atmospheric Monitor Failed to Operate Properly & Low Sample Flow Was Noted. Caused by Condensate Drain Pot Solenoid Valve Failure Which Blocked Sample Flow.Solenoid Valve Was Replaced + (ML19253C346)
- 05000265/LER-1979-025-03, /03L-0:on 791026,during Lcpi Motor Operated Valve Operability Test,Motor Control Breaker Tripped on Thermal Overload.Caused by Tripping Circuit Breaker.Motor Meggared + (ML19253C347)
- ML19253C348 + (ML19253C348)
- ML19253C349 + (ML19253C349)
- ML19253C350 + (ML19253C350)
- ML19253C352 + (ML19253C352)
- IR 05000413/1979018 + (ML19253C353)
- ML19253C354 + (ML19253C354)
- ML19253C355 + (ML19253C355)
- ML19253C356 + (ML19253C356)
- ML19253C357 + (ML19253C357)
- ML19253C358 + (ML19253C358)
- ML19253C359 + (ML19253C359)
- ML19253C360 + (ML19253C360)
- ML19253C361 + (ML19253C361)
- ML19253C362 + (ML19253C362)
- ML19253C363 + (ML19253C363)
- ML19253C364 + (ML19253C364)
- ML19253C365 + (ML19253C365)
- ML19253C366 + (ML19253C366)
- ML19253C367 + (ML19253C367)
- ML19253C368 + (ML19253C368)
- ML19253C369 + (ML19253C369)
- ML19253C370 + (ML19253C370)
- ML19253C371 + (ML19253C371)
- ML19253C372 + (ML19253C372)
- ML19253C374 + (ML19253C374)
- IR 05000312/1979016 + (ML19253C375)
- ML19253C376 + (ML19253C376)
- ML19253C377 + (ML19253C377)
- ML19253C378 + (ML19253C378)