- ML18153B454 + (ML18153B454)
- IR 05000280/1993028 + (ML18153B456)
- IR 05000280/1993030 + (ML18153B457)
- ML18153B459 + (ML18153B459)
- ML18153B460 + (ML18153B460)
- ML18153B461 + (ML18153B461)
- IR 05000280/1993026 + (ML18153B462)
- 05000281/LER-1994-001-01, :on 940124,both Auxiliary Exhaust Filter Trains Declared Inoperable Due to Excessive flow.Six-h Action Statement to Hot Shutdown of Facility Entered Until Normal 1J Bus Alignment Restored + (ML18153B463)
- ML18153B465 + (ML18153B465)
- ML18153B466 + (ML18153B466)
- ML18153B467 + (ML18153B467)
- ML18153B469 + (ML18153B469)
- IR 05000280/1988017 + (ML18153B471)
- ML18153B472 + (ML18153B472)
- IR 05000280/1988023 + (ML18153B474)
- ML18153B475 + (ML18153B475)
- ML18153B476 + (ML18153B476)
- ML18153B477 + (ML18153B477)
- ML18153B478 + (ML18153B478)
- ML18153B479 + (ML18153B479)
- ML18153B481 + (ML18153B481)
- 05000281/LER-1988-015-02, :on 880626,rod Urgent Failure Annunciator Activated in Control Room.Caused by Failed Circuit Card & Blown Fuse.Failed Circuit Card & Blown Fuse Replaced & Rod Control Sys Tested Satisfactorily + (ML18153B482)
- ML18153B483 + (ML18153B483)
- ML18153B484 + (ML18153B484)
- ML18153B485 + (ML18153B485)
- ML18153B486 + (ML18153B486)
- IR 05000280/1988022 + (ML18153B488)
- 05000280/LER-1988-020, :on 880628,control/relay Room Chiller Condenser Svc Water (SW) Pumps & Unit 2 Charging Pump SW Pumps Lost Suction.Caused by Inadequate Procedure.Filling of SW Supply Line Secured & Supply Header Vented + (ML18153B489)
- ML18153B490 + (ML18153B490)
- ML18153B491 + (ML18153B491)
- ML18153B492 + (ML18153B492)
- ML18153B493 + (ML18153B493)
- ML18153B494 + (ML18153B494)
- ML18153B495 + (ML18153B495)
- 05000280/LER-1988-021, :on 880728,PORV Cycled Open & Then Closed. Caused by Overly Conservative Setpoint.Setpoint Changed + (ML18153B496)
- IR 05000280/1988011 + (ML18153B498)
- ML18153B499 + (ML18153B499)
- 05000281/LER-1988-016-02, :on 880731,discovered That Individual Rod Position Indicators (Irpis) Differed from Group Step Demand Counter by Greater than 12 Steps.Caused by Drift in Irpi Indication.Irpis Adjusted + (ML18153B500)
- ML18153B501 + (ML18153B501)
- IR 05000280/1988003 + (ML18153B502)
- ML18153B503 + (ML18153B503)
- ML18153B505 + (ML18153B505)
- ML18153B506 + (ML18153B506)
- ML18153B507 + (ML18153B507)
- 05000281/LER-1988-019-03, :on 880901,steam Generator a Inside Containment Steam Valve Closed for No Apparent Reason Due to Actuation of High Flow Trip Solenoid.Solenoid Reset,Blowdown Flow Established & Trip Valve & Solenoid Verified + (ML18153B508)
- 05000280/LER-1988-035, :on 880914,specific Activity Sample of Reactor Coolant Showed Dose Equivalent I-131 Level of 1.04 Microcuries/Cc,Exceeding Tech Spec Limits.Caused by Iodine Spike Due to Fuel Element Defects + (ML18153B509)
- ML18153B510 + (ML18153B510)
- ML18153B512 + (ML18153B512)
- ML18153B513 + (ML18153B513)
- PNO-II-88-061, during Wk of 880919,util Identified Some Pipe Wall Thinning in Main Feedwater Piping.On or About 880926, Util Identified Main Feedwater Piping Below Min Code Requirements for Acceptability.Nrc Being Kept Informed + (ML18153B514)
- ML18153B515 + (ML18153B515)