- 05000311/LER-1993-004, :on 930206,both Main Turbine first-stage Impulse Pressure Indication Channels Indicated False Readings.Caused by Inadequate Sensing Line Protection. Failed Heat Tracing Will Be Repaired + (ML18096B326)
- ML18096B327 + (ML18096B327)
- ND-18-0417, Supplement to Request for License Amendment and Exemption: Changes to Tier 2 Departure Evaluation Process + (ML18096B328)
- ML18096B329 + (ML18096B329)
- ML18096B330 + (ML18096B330)
- ML18096B331 + (ML18096B331)
- IR 05000272/1993005 + (ML18096B333)
- ML18096B334 + (ML18096B334)
- ML18096B335 + (ML18096B335)
- ML18096B336 + (ML18096B336)
- ML18096B337 + (ML18096B337)
- ML18096B339 + (ML18096B339)
- ML18096B340 + (ML18096B340)
- ML18096B341 + (ML18096B341)
- ML18096B342 + (ML18096B342)
- ML18096B343 + (ML18096B343)
- 05000272/LER-1993-004-01, :on 930216,automatic Reactor Trip Occurred Due to Overtemperature Delta Temp Signal.Caused by Equipment Failure.Module Output Gain Selector Switch 1QM411B Cleaned & Exercised & Capacitors Replaced + (ML18096B344)
- ML18096B345 + (ML18096B345)
- IR 05000272/1992016 + (ML18096B346)
- ML18096B347 + (ML18096B347)
- ML18096B348 + (ML18096B348)
- ML18096B349 + (ML18096B349)
- 05000272/LER-1993-005, :on 930218,experienced Reactor Protection Sys Reactor Trip/Turbine Trip Signal,When 12 SG Level Decreased. Caused by Personnel Error.Event Will Be Reviewed for Incorporation in Applicable Training Program + (ML18096B350)
- ML18096B351 + (ML18096B351)
- 05000272/LER-1993-006, :on 930221,station Power Transformers 12 & 22 Deenergized Due to Tripping of Common 13 Kv Ring Bus Section 4 Breakers & 500 Kv Section 1 Breakers.Caused by Inadequate Communication.Caution Tags Hung on Breakers + (ML18096B352)
- ML18096B353 + (ML18096B353)
- ML18096B354 + (ML18096B354)
- ML18096B355 + (ML18096B355)
- ML18096B356 + (ML18096B356)
- ML18096B357 + (ML18096B357)
- ML18096B358 + (ML18096B358)
- 05000272/LER-1992-026, :on 921213,EFS Actuations Occurred.Caused by Increased Containment Activity.Leakage Stopped by Backseating Valves + (ML18096B359)
- ML18096B360 + (ML18096B360)
- ML18096B361 + (ML18096B361)
- 05000272/LER-1993-007, :on 930225,initial Investigation Indicated High Resistance Readings at Coil Stacks Resulting to TS 3.0.3 Entry.Caused by Sys Design.Review of Event in Progress & C/A Will Be Implemented Based on Results + (ML18096B362)