List of results
- ML18082A540 + (ML18082A540)
- ML18082A541 + (ML18082A541)
- ML18082A542 + (ML18082A542)
- ML18082A548 + (ML18082A548)
- ML18082A549 + (ML18082A549)
- ML18082A550 + (ML18082A550)
- ML18082A551 + (ML18082A551)
- ML18082A552 + (ML18082A552)
- ML18082A553 + (ML18082A553)
- ML18082A554 + (ML18082A554)
- PNO-I-80-083, on 800523,woman Security Guard Passed Out While Resting in Guard House During Break.Ambulance Called Immediately to Transport Patient to Offsite Hosp for Observation + (ML18082A555)
- ML18082A557 + (ML18082A557)
- 05000272/LER-1980-026, Forwards LER 80-026/03L-0 + (ML18082A558)
- ML18082A560 + (ML18082A560)
- 05000272/LER-1980-026-03, /03L-0:on 800516,while Performing Routine Surveillance,Level Transmitter for Steam Generator Level Channel IV for Low Level Trip Setpoint Was Found Out of Spec.Caused by Failed Capacitors within Circuitry + (ML18082A562)
- NLS2018012, Response to Nuclear Regulatory Commission Request for Additional Information for Relief Request RI5-03 + (ML18082A563)
- ML18082A564 + (ML18082A564)
- ML18082A565 + (ML18082A565)
- 05000272/LER-1980-025, Forwards LER 80-025/03L-0 + (ML18082A567)
- ML18082A568 + (ML18082A568)
- 05000272/LER-1980-025-03, /03L-0:on 800516,during Containment Entry,Steam Noticed Coming from Area Where Reactor Coolant Sample Lines Pass Through Containment Wall.Caused by Failure of Sample Line & Seal Weld on Penetration.Penetration Weld Repaired + (ML18082A569)
- IR 05000272/1980007 + (ML18082A572)
- ML18082A573 + (ML18082A573)
- ML18082A577 + (ML18082A577)
- ML18082A578 + (ML18082A578)
- ML18082A579 + (ML18082A579)
- ML18082A580 + (ML18082A580)
- ML18082A584 + (ML18082A584)
- ML18082A585 + (ML18082A585)
- ML18082A587 + (ML18082A587)
- ML18082A591 + (ML18082A591)
- ML18082A592 + (ML18082A592)
- ML18082A593 + (ML18082A593)
- ML18082A595 + (ML18082A595)
- ML18082A596 + (ML18082A596)
- 05000272/LER-1980-028, Forwards LER 80-028/03L-0 + (ML18082A597)
- ML18082A598 + (ML18082A598)
- ML18082A599 + (ML18082A599)
- ML18082A600 + (ML18082A600)
- 05000272/LER-1980-028-03, /03L-0:on 800519,while Reviewing Records, Discovered That Surveillance Requirement 4.3.3.6.2 Was Not Completed During Required Interval.Caused by Lack of Timely Review.Surveillance Completed + (ML18082A601)
- ML18082A602 + (ML18082A602)
- ML18082A603 + (ML18082A603)
- ML18082A604 + (ML18082A604)
- ML18082A606 + (ML18082A606)
- 05000311/LER-1980-001, Forwards LER 80-001/03L-0 + (ML18082A607)
- ML18082A608 + (ML18082A608)
- ML18082A609 + (ML18082A609)
- 05000311/LER-1980-001-03, /03L-0:on 800522,when OL Received,Fire Barriers Were Open Due to Recent Removal of Electrical Cables,Pipes & Welding Cables.Cause Not Stated.Barriers Were Verified Sealed Prior to Core Load + (ML18082A610)
- 05000272/LER-1980-027, Forwards LER 80-027/03L-0 + (ML18082A612)
- ML18082A614 + (ML18082A614)
- 05000272/LER-1980-027-03, /03L-0:on 800521,evaluation of Need to Perform Insp of Fire Pump Diesel Engine Was Not Made as Required Every 18 Months by Tech Specs.Caused by Faulty Tracking Sys. Sys Corrected to Ensure Timely Review + (ML18082A616)