- IR 05000255/1988027 + (ML18054A541)
- ML18054A542 + (ML18054A542)
- ML18054A543 + (ML18054A543)
- ML18054A544 + (ML18054A544)
- ML18054A546 + (ML18054A546)
- ML18054A547 + (ML18054A547)
- ML18054A551 + (ML18054A551)
- ML18054A552 + (ML18054A552)
- ML18054A554 + (ML18054A554)
- ML18054A555 + (ML18054A555)
- ML18054A559 + (ML18054A559)
- ML18054A560 + (ML18054A560)
- ML18054A561 + (ML18054A561)
- 05000255/LER-1989-001-01, :on 890127,primary Coolant Sys Leak Rate Determination Not Completed,Per Plant Tech Specs Table 4.2.2,Item 8.Caused by in-progress Plant Derate.Leak Rate Determination Completed & Evaluation Ongoing + (ML18054A563)
- ML18054A564 + (ML18054A564)
- ND-18-0227, Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item 2.5.05.02.i (Index Number 565) + (ML18054A565)
- ML18054A566 + (ML18054A566)
- ML18054A567 + (ML18054A567)
- ML18054A568 + (ML18054A568)
- ML18054A569 + (ML18054A569)
- PNO-III-89-014, on 890218,plant Operator Observed Leakage from Primary Cooling Sys Through Drain Line Into Primary Sys Drain Tank.Lines Being Removed & Capped Downstream from Drain Valves.Effort Expected to Be Completed by 890222 + (ML18054A570)
- ML18054A571 + (ML18054A571)
- ML18054A575 + (ML18054A575)
- ML18054A578 + (ML18054A578)
- ML18054A579 + (ML18054A579)
- ML18054A580 + (ML18054A580)
- ML18054A582 + (ML18054A582)
- ML18054A583 + (ML18054A583)
- ML18054A584 + (ML18054A584)
- ML18054A585 + (ML18054A585)
- IR 05000255/1989002 + (ML18054A587)
- ML18054A588 + (ML18054A588)
- IR 05000255/1989003 + (ML18054A590)
- ML18054A591 + (ML18054A591)
- ML18054A592 + (ML18054A592)
- 05000255/LER-1989-003-01, :on 890218,plant Cooldown from Hot Shutdown Condition Initiated Due to Primary Coolant Sys Leakage Through Cold Leg Drain Valves.Drain Lines Capped Downstream of Loop Isolation Valves + (ML18054A594)
- ML18054A595 + (ML18054A595)
- ML18054A603 + (ML18054A603)
- ML18054A605 + (ML18054A605)
- IR 05000255/1988020 + (ML18054A606)
- 05000255/LER-1989-002-01, :on 890215,pressurizer PORV Opened Due to Primary Coolant Sys Pressure Spike.Caused by Air Entrainment in Primary Coolant Sys.Pressurizer PORV & Associated Pilot Valve Repaired + (ML18054A607)
- ML18054A608 + (ML18054A608)
- ML18054A610 + (ML18054A610)
- ML18054A613 + (ML18054A613)
- ML18054A617 + (ML18054A617)
- 05000255/LER-1989-005, :on 890303,diesel Generator Operation Failed to Meet & Maintain Required Fuel Oil Capacity.Caused by Failure to Update Diesel Fuel Oil Consumption Calculations.Storage Tank Filled to Meet Required Min + (ML18054A618)
- ML18054A619 + (ML18054A619)
- ML18054A621 + (ML18054A621)
- ML18054A622 + (ML18054A622)
- 05000255/LER-1989-004, :on 890228,reactor Trip Occurred During Performance of Tech Spec Surveillance Procedure RO-21, Control Rod Drive Sys Interlocks. Caused by Inadequate Procedure.Surveillance Procedure RO-21 Revised + (ML18054A623)
- ND-18-0213, Notice of Uncompleted ITAAC 225-days Prior to Initial Fuel Load Item E.3.9.06.00.03 (Index Number 861) + (ML18054A624)