Search by property
Jump to navigation
Jump to search
This page provides a simple browsing interface for finding entities described by a property and a named value. Other available search interfaces include the page property search, and the ask query builder.
List of results
- 05000315/LER-1979-029-03, /03L-0 on 790414:cracks Discovered in Divider Barrier Seal.Caused by Excessive Compression of Seal Matl by Steel Plates.Work in Progress to Replace Cracked Sections + (ML17317B207)
- ML17317B208 + (ML17317B208)
- ML17317B209 + (ML17317B209)
- 05000315/LER-1979-030-03, /03L-0 on 790417:while Performing Routine Surveillance Test on AB Diesel Generator,Load Conservation Circuitry Did Not Fully Function as Design.Cause Under Investigation + (ML17317B210)
- 05000315/LER-1979-031-03, /03L-0 on 790419:during Routine Channel Calibr, Bistable Trip Value Discovered Nonconservative W/Respect to Tech Spec Limits.Caused by Excess Drift.Bistable Will Be Repaired + (ML17317B211)
- 05000315/LER-1979-032-03, /03L-0 on 790416:during Routine Channel Calibr, Bistable FB-510B Trip Point Was Nonconservative W/Respect to Tech Spec Limit.Caused by Excess Drift.Bistable Recalibr + (ML17317B212)
- 05000316/LER-1979-017, Forwards LER 79-017/03L-0 + (ML17317B213)
- ML17317B214 + (ML17317B214)
- 05000316/LER-1979-017-03, /03L-0 on 790423:while Performing STP 022, Essential Svc water-142, Essential Svc Valve to 2 Cd Diesel Did Not Seat Properly.Caused by Excessive Wear of Split Disc Hinge Points.Stainless Steel Discs Were Substituted + (ML17317B215)
- ML17317B216 + (ML17317B216)
- ML17317B217 + (ML17317B217)
- ML17317B219 + (ML17317B219)
- ML17317B220 + (ML17317B220)
- ML17317B221 + (ML17317B221)
- ML17317B222 + (ML17317B222)
- ML17317B223 + (ML17317B223)
- ML17317B224 + (ML17317B224)
- ML17317B235 + (ML17317B235)
- ML17317B236 + (ML17317B236)
- ML17317B238 + (ML17317B238)
- 05000316/LER-1979-018, Forwards LER 79-018/03L-0 + (ML17317B239)
- ML17317B240 + (ML17317B240)
- 05000316/LER-1979-018-03, /03L-0 on 790423:during Investigation of Periodic Alarms for Steam Generator High Steam Line Flow,Controller 2 Py 506B (Turbine Impulse Pressure) Was in Manual Control. Caused by Controller Not Being Returned to Automatic + (ML17317B241)
- ML17317B242 + (ML17317B242)
- ML17317B243 + (ML17317B243)
- ML17317B244 + (ML17317B244)
- ML17317B245 + (ML17317B245)
- ML17317B246 + (ML17317B246)
- ML17317B247 + (ML17317B247)
- ML17317B248 + (ML17317B248)
- ML17317B250 + (ML17317B250)
- 05000315/LER-1979-033, Forwards LER 79-033/03L-0 + (ML17317B252)
- ML17317B253 + (ML17317B253)
- 05000315/LER-1979-033-03, /03L-0 on 790308:monthly Functional Tests for Containment Area Monitor,Containment atmosphere-particulate & Containment atmosphere-gaseous Monitors Were Not Performed.Caused by Daily Assignment Error + (ML17317B254)
- ML17317B255 + (ML17317B255)
- ML17317B256 + (ML17317B256)
- ML17317B258 + (ML17317B258)
- ML17317B259 + (ML17317B259)
- ML17317B261 + (ML17317B261)
- 05000315/LER-1979-019, Forwards LER 79-019/01T-0 + (ML17317B262)
- ML17317B263 + (ML17317B263)
- 05000315/LER-1979-019-01, /01T-0 on 790519:cracks Found in 16-inch Feedwater Elbows Adjacent to Nozzle Welds Caused Buildup of Nonradioactive Water in Containment Sump.Caused Being Determined.Elbows in Generators Being Replaced + (ML17317B264)
- ML17317B265 + (ML17317B265)
- ML17317B266 + (ML17317B266)
- ML17317B267 + (ML17317B267)
- ML17317B268 + (ML17317B268)
- ML17317B269 + (ML17317B269)
- ML17317B270 + (ML17317B270)
- ML17317B271 + (ML17317B271)
- 05000316/LER-1979-019, Forwards LER 79-019/01X-1 + (ML17317B272)
- ML17317B273 + (ML17317B273)