- 05000315/LER-1978-069-03, /03L-0 on 781010:axial Flux Difference Monitoring Alarm Point Discovered Set Above Tech Spec Max.Caused by Raising of Alarm Trip Point During Preoperational Test Failure to Return to Required Value at End + (ML17317A959)
- 05000315/LER-1979-003-03, /03L-0 on 790120:during Review of Completed Surveillance Tests,Discovered That Test on Solid State Protection Sys Train a Exceed 1-h Limit Imposed by Tech Specs.Caused by Technician Overlooking 1-h Limit + (ML17317A960)
- 05000315/LER-1979-004, Forwards LER 79-004/03L-0 + (ML17317A961)
- 05000315/LER-1979-004-03, /03L-0 on 790206:both Doors of Containment Airlock Were Inadvertently Opened.Caused by Interlock Cable Being Too Loose to Operate Locking Mechanism.Tension Was Adjusted & Interlock Then Tested Satisfactorily + (ML17317A962)
- IR 05000315/1978027 + (ML17317A964)
- ML17317A966 + (ML17317A966)
- ML17317A967 + (ML17317A967)
- ML17317A968 + (ML17317A968)
- ML17317A969 + (ML17317A969)
- IR 05000315/1978032 + (ML17317A971)
- ML17317A972 + (ML17317A972)
- ML17317A973 + (ML17317A973)
- IR 05000315/1978036 + (ML17317A974)
- IR 05000313/1978036 + (ML17317A976)
- ML17317A977 + (ML17317A977)
- ML17317A978 + (ML17317A978)
- ML17317A979 + (ML17317A979)
- IR 05000315/1978037 + (ML17317A981)
- ML17317A982 + (ML17317A982)
- ML17317A983 + (ML17317A983)
- 05000315/LER-1979-005-03, /03L-0 on 780624:unit Was Operated W/Positive Moderator Temp Coefficient for 3-h.Caused by Rod Withdrawal & Consequent Xe Build Up.Procedure Being Revised + (ML17317A984)
- 05000315/LER-1979-006-03, /03L-0 on 790208:pressurizer Relief Tank Diaphragm Ruptured,Causing Ice Condenser Inlet Doors to Be Indicated Open.Caused by Pressure Surge in Lower Containment.Unit Shut Down & Doors Closed + (ML17317A985)
- L-17-328, Spent Fuel Storage Casks Registration + (ML17317A986)
- ML17317A988 + (ML17317A988)
- ML17317A989 + (ML17317A989)
- ML17317A990 + (ML17317A990)
- IR 05000316/1978035 + (ML17317A991)
- ML17317A993 + (ML17317A993)
- ML17317A994 + (ML17317A994)
- ML17317A996 + (ML17317A996)
- IR 05000315/1978038 + (ML17317A997)
- 05000316/LER-1979-007, Forwards LER 79-007/03L-0 + (ML17317A998)
- ML17317B000 + (ML17317B000)
- 05000316/LER-1979-007-03, /03L-0 on 790213:during Surveillance Test on Containment Pressure Set 3,high-high Bistable Trip Point Was Found to Exceed Tech Specs.Caused by Drifting Bistable. Bistable,Westinghouse Model 63V-BC-OHEA-F,was Replaced + (ML17317B001)
- ML17317B002 + (ML17317B002)
- ML17317B003 + (ML17317B003)
- ML17317B004 + (ML17317B004)
- 05000315/LER-1979-007-03, /03L-0 on 790218:suction Valve of West Centrifugal Charging Pump Found Closed.Caused by Mistaken Closing Following Surveillance Testing.Incident Is Being Reviewed + (ML17317B005)
- 05000315/LER-1979-008-03, /03L-0 on 790207:containment Atmospheric Air Particulate & Gaseous Radiation Monitoring Sys Pump Was Continuously Tripping.Caused by Misalignment of Pump Bypass Flow Adjustments Due to Normal Pump Wear.Flow Rate Adjusted + (ML17317B006)
- 05000315/LER-1979-009-03, /03L-0 on 790223:in Mode 1 Both Emergency Diesel Generators Were Inoperable on Separate Occasions.Caused by AB Diesel Generator Running in Parallel & Other Emergency Generator Out for Maint.Operating Procedures Revised + (ML17317B007)