L-17-328, Spent Fuel Storage Casks Registration

From kanterella
Jump to navigation Jump to search
Spent Fuel Storage Casks Registration
ML17317A986
Person / Time
Site: Beaver Valley, 07201043, 07201004
(DPR-066, NPF-073)
Issue date: 11/13/2017
From: Bologna R
FirstEnergy Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Material Safety and Safeguards
References
L-17-328
Download: ML17317A986 (2)


Text

November 13, 2017 FENOC' 2'

FirstEnergy Nuclear Operating Company Richard D. Bologna Site Vice President L-17-328 A TIN: Document Control Desk Director, Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

SUBJECT:

Beaver Valley Power Station, Unit Nos. 1 and 2 Docket No. 50-334, License No. DPR-66 Docket No. 50-412, License No. NPF-73 Docket No. 72-1043 Spent Fuel Storage Casks Registration Beaver Valley Power Station P.O. Box4 Shippingport, PA 15077 724-682-5234 Fax: 724-643-8069 10 CFR 72.212 In accordance with the registration requirements of 10 CFR 72.212(b)(2), FirstEnergy Nuclear Operating Company (FENOC) is providing the enclosed information to register the spent fuel storage casks at the Beaver Valley Power Station (BVPS) independent spent fuel storage installation (ISFSI).

There are no regulatory commitments contained in this letter. If there are any questions or if additional information is required, please contact Mr. Benjamin L. Spiesman, FENOC Fleet Licensing at (440) 280-6356.

Richard D. Bologna

Attachment:

Spent Fuel Storage Casks Registration Information cc:

NRC Region I Administrator NRC Resident Inspector NRC Project Manager Director BRP/DEP Site BRP/DEP Representative

Attachment L-17-328 Spent Fuel Storage Casks Registration Information Page 1 of 1 The following information is provided in accordance with 10 CFR 72.212(b)(2) for the registration information of the recently loaded spent fuel storage casks at the Beaver Valley Power Station:

Licensee Name:

Licensee Address:

Reactor License Numbers:

Reactor Docket Numbers:

Independent Spent Fuel FirstEnergy Nuclear Operating Company (FENOC)

Beaver Valley Power Station Unit Nos. 1 and 2 P.O. Box 4, Route 168 Shippingport, Pennsylvania 15077 DPR-66 (Unit No. 1 ), NPF-73 (Unit No. 2) 50-334 (Unit No. 1 ), 50-412 (Unit No. 2)

Storage Installation Docket Number: 72-1043 Contact Name and

Title:

Cask Certificate Number and Certificate of Compliance (CoC)

Amendment Number:

Cask Model Number:

Service Date:

Cask Identification Number:

Service Date:

Cask Identification Number:

Benjamin L. Spiesman FENOC Fleet Licensing Engineer Transuclear Americas LLC 1004; Amendment 13, Revision 1 NUHOMS 37PTH-S October 18, 2017 Dry Shielded Canister (DSC) Serial Number: BV-37PTH-S-3-07 Horizontal Storage Module (HSM)

Number: BV-3-HSM7 October 25, 2017 Dry Shielded Canister (DSC) Serial Number: BV-37PTH-S-3-08 Horizontal Storage Module (HSM)

Number: BV-3-HSM8

November 13, 2017 FENOC' 2'

FirstEnergy Nuclear Operating Company Richard D. Bologna Site Vice President L-17-328 A TIN: Document Control Desk Director, Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

SUBJECT:

Beaver Valley Power Station, Unit Nos. 1 and 2 Docket No. 50-334, License No. DPR-66 Docket No. 50-412, License No. NPF-73 Docket No. 72-1043 Spent Fuel Storage Casks Registration Beaver Valley Power Station P.O. Box4 Shippingport, PA 15077 724-682-5234 Fax: 724-643-8069 10 CFR 72.212 In accordance with the registration requirements of 10 CFR 72.212(b)(2), FirstEnergy Nuclear Operating Company (FENOC) is providing the enclosed information to register the spent fuel storage casks at the Beaver Valley Power Station (BVPS) independent spent fuel storage installation (ISFSI).

There are no regulatory commitments contained in this letter. If there are any questions or if additional information is required, please contact Mr. Benjamin L. Spiesman, FENOC Fleet Licensing at (440) 280-6356.

Richard D. Bologna

Attachment:

Spent Fuel Storage Casks Registration Information cc:

NRC Region I Administrator NRC Resident Inspector NRC Project Manager Director BRP/DEP Site BRP/DEP Representative

Attachment L-17-328 Spent Fuel Storage Casks Registration Information Page 1 of 1 The following information is provided in accordance with 10 CFR 72.212(b)(2) for the registration information of the recently loaded spent fuel storage casks at the Beaver Valley Power Station:

Licensee Name:

Licensee Address:

Reactor License Numbers:

Reactor Docket Numbers:

Independent Spent Fuel FirstEnergy Nuclear Operating Company (FENOC)

Beaver Valley Power Station Unit Nos. 1 and 2 P.O. Box 4, Route 168 Shippingport, Pennsylvania 15077 DPR-66 (Unit No. 1 ), NPF-73 (Unit No. 2) 50-334 (Unit No. 1 ), 50-412 (Unit No. 2)

Storage Installation Docket Number: 72-1043 Contact Name and

Title:

Cask Certificate Number and Certificate of Compliance (CoC)

Amendment Number:

Cask Model Number:

Service Date:

Cask Identification Number:

Service Date:

Cask Identification Number:

Benjamin L. Spiesman FENOC Fleet Licensing Engineer Transuclear Americas LLC 1004; Amendment 13, Revision 1 NUHOMS 37PTH-S October 18, 2017 Dry Shielded Canister (DSC) Serial Number: BV-37PTH-S-3-07 Horizontal Storage Module (HSM)

Number: BV-3-HSM7 October 25, 2017 Dry Shielded Canister (DSC) Serial Number: BV-37PTH-S-3-08 Horizontal Storage Module (HSM)

Number: BV-3-HSM8