IR 05000315/1978036
| ML17317A974 | |
| Person / Time | |
|---|---|
| Site: | Cook |
| Issue date: | 01/15/1979 |
| From: | Fiorelli G NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III) |
| To: | Dolan J AMERICAN ELECTRIC POWER CO., INC. |
| Shared Package | |
| ML17317A975 | List: |
| References | |
| NUDOCS 7903080486 | |
| Download: ML17317A974 (3) | |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION
REGION III
799 ROOSEVELT ROAD ( I.EN ELLYN, ILLINOI'9137 Docket No. 50-315/jg-P&
Docket No. 50-316 American Electric Power Service Corporation Indiana and Michigan Power Company ATTN:
Mr. John E. Dolan, Senior Executive Vice President Engineering 2 Broadway New York, NY 10004 Gentlemen:
This refers to this office on and 4-8, 1978, Plant, Units 1 DPR-58 and No.
with Mr. D. V.
the conclusion the inspection conducted by Mr. K. R. Baker of November 7-9, 13-17, 20-22, 27-30; December
of activities at Donald C.
Cook Nuclear Power and 2 authorized by NRC Operating Licenses No.
DPR-74 and to the discussion of our findings Shaller and other members of your staff at of the inspection.
The enclosed copy of our inspection report identifies areas examined during the inspection.
Within these areas, the inspection consisted of a selective examination of procedures and representative'records, observations, and interviews with personnel.
No items of noncompliance with NRC requirements were identified during the course of this inspection.
In accordance with Section 2.790 of the NRC's "Rules of Practice," Part 2, Title 10, Code of Federal Regulations, a
copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Room, except as follows.
If this report contains information that you or your contractors believe to be proprietary, you must apply in writing to this office, within twenty days of your receipt of this letter, to withhold such information from public disclosure.
The application must include a full statement of the reasons for which the information is considered proprietary, and should be prepared so that proprietary information identified in the application is contained in an enclosure to the applicatio F M
li
American Electric Power Service Corporation Indiana and Michigan Power Company JAa Is Sss We villgladly discuss any questions you have concerning this inspection.
Sincerely, Gaston Piorelli, Chief Reactor Operations and Nuclear Support Branch Enclosure:
IE Inspection Rpts No. 50-315/78-36 and No. 50-316/78-37 cc w/enclz D. V. Sheller, Plant Hanager J Central Piles Reproduction Unit NRC 20b PDR Local PDR NSIC
.TIC Ronald Callen, Hichigan Public Service Commission David D. Comey, Executive Director,'Citizens for a Better Environment RIIIaA"
@(+----
Baker/dec RIIIL'5 Warnick OFFICCi rel i SURNAME+
OAT~ 1/6/79 (gal%
NRC Form 3188 (RIZZ) {1-78) NRCM 0240
~U. 5. OOVKRNMCNTPAINTINOOPFICCs lOll $ $ $4$ $