- ML17290A173 + (ML17290A173)
- ML17290A175 + (ML17290A175)
- GO2-93-081, Advises That Further Work on Improved TS Program Deferred Until FY95 (940701).Submittal of Program,Based on Restart of Program in Jul 1994,anticipated to Be Mar 1995 + (ML17290A176)
- 05000397/LER-1993-012, :on 930311,Sys Engineer Learned That Fast Open Function of Main Turbine BPV Was Not Operable.Caused by Less than Adequate Surveillance Procedures.No Immediate Corrective Actions Were Required + (ML17290A178)
- 05000397/LER-1993-001-01, :on 930310,determined That Previously Performed Surveillance Testing Had Not Been Fully Adequate to Demonstrate Operability of Hoists.Caused by Error by Nonlicensed Util Personnel.Calibration Revised + (ML17290A179)
- GO2-93-079, Suppls 880928 Response to NRC Bulletin 88-004, Potential Safety-Related Pump Loss, Submitting Results of Analysis by Ingersoll-Rand in long-term Development Evaluation for Applicable ECCS Pumps + (ML17290A181)
- GO2-93-075, Application for Amend to License NPF-21,adding Note to Spec 3.7.3, RCIC Sys to Allow for RCIC to Be Assumed Operable W/Rcic Suction Aligned to Condensate Storage Tank + (ML17290A182)
- ML17290A183 + (ML17290A183)
- ML17290A184 + (ML17290A184)
- GO2-93-076, Application for Amend to License NPF-21,changing TS Covering Implementation of ISI Program for Austenitic Stainless Steel Piping,Per GL 88-01 + (ML17290A185)
- ML17290A186 + (ML17290A186)
- ML17290A187 + (ML17290A187)
- GO2-93-077, Application for Amend to License NPF-21,changing TS 3.8.1.1.b.2 & 3.8.1.2.b Re DG Fuel Storage Sys Capacities, in Response to Edsfi Rept 50-397/92-01 + (ML17290A188)
- ML17290A190 + (ML17290A190)
- ML17290A191 + (ML17290A191)
- ML17290A192 + (ML17290A192)
- ML17290A194 + (ML17290A194)
- ML17290A196 + (ML17290A196)
- ML17290A197 + (ML17290A197)
- GO2-93-086, Discusses Commitments in Response to Weaknesses Noted in Insp Rept 50-397/92-35 Re Control of Radioactive Liquids Released to Stormwater Drainage Pond + (ML17290A199)
- ML17290A200 + (ML17290A200)
- ML17290A201 + (ML17290A201)
- ML17290A206 + (ML17290A206)
- ML17290A207 + (ML17290A207)
- ML17290A208 + (ML17290A208)
- ML17290A210 + (ML17290A210)
- IR 05000397/1993009 + (ML17290A212)
- ML17290A213 + (ML17290A213)
- ML17290A215 + (ML17290A215)
- ML17290A217 + (ML17290A217)
- ML17290A219 + (ML17290A219)
- ML17290A220 + (ML17290A220)
- ML17290A222 + (ML17290A222)
- ML17290A225 + (ML17290A225)
- ML17290A226 + (ML17290A226)
- GO2-93-087, Informs That Revs of EOPs Has Been Implemented for Plant Operations on 930409 After Successful Conclusions of Two Cycles of Requalification Training + (ML17290A228)
- ML17290A229 + (ML17290A229)
- IR 05000397/1993010 + (ML17290A231)
- ML17290A233 + (ML17290A233)
- IR 05000397/1993002 + (ML17290A235)
- IR 05000397/1992027 + (ML17290A239)
- ML17290A240 + (ML17290A240)
- GO2-93-091, Responds to NRC Re Violations Noted in Insp Rept 50-397/92-43 on 921228-930206.Corrective Actions:Plant Procedure Re Restart Evaluation Process Will Be Revised to Incorporate Improvements in Mgt Time Out + (ML17290A247)
- ML17290A248 + (ML17290A248)
- GO2-93-089, Advises That Wg Counsil Assumed Position of Managing Director of Wpps,Replacing DW Mazur on 930405.DW Mazur Resigned in 1992 Due to Health Reasons + (ML17290A249)
- GO2-93-094, Responds to NRC Re Violations Noted in Insp Rept 50-397/93-07.Corrective Actions:Line Mgt Has Initiated Frequent Plant Walkdowns to Ensure Compliance W/Ppm 1.3.19 & Provide Immediate Feedback to Upper Mgt + (ML17290A250)
- ML17290A252 + (ML17290A252)
- GO2-93-096, Responds to NRC Re Notice of Violation & Proposed Imposition of Civil Penalty from Insp Rept 50-397/92-41. Corrective Actions:Util Will Benchmark Radwaste Program W/ Other Selected Utils to Ensure Consistency W/Industry Stds + (ML17290A253)
- GO2-93-102, Responds to NRC Re Violations Noted in Insp Rept 50-397/93-08.Corrective Actions:Plant QA Organization Will Develop Plan to Improve Prioritization,Tracking & Follow Up on C/As Resulting from Quality Finding Rept + (ML17290A263)
- 05000397/LER-1993-015, :on 930331,unusual Event Declared as Result of Inoperability of HPCS Sys from Low Svc Water Flow Through HPCS Pump Room Cooler,Coincident w/930318 Inoperability of Rcic.Caused by Component Defect.Flow Revised + (ML17290A264)
- GO2-93-095, WNP-2 Cooling Water Blowdown Discharges,1992 + (ML17290A267)