Semantic search

Jump to navigation Jump to search
 Issue dateTitleTopic
ML23312A1307 November 2023Final Rci/Rai - Constellation R. E. Ginna Nuclear Power Plant - Exemption from Security Rule (EPID L-2023-LLE-0029) (Email)Time of Discovery
Fitness for Duty
Contraband
ML22160A3969 June 2022R. E. Ginna Nuclear Power Plant, LLC - Request for Information for a Biennial Problem Identification and Resolution Inspection; Inspection Report 05000244/2022010Temporary Modification
ML22271A0776 May 2022NRR E-mail Capture - Final RAIs 9.1.2021 Constellation Relief Request
ML22129A0136 May 2022NRR E-mail Capture - Draft RAIs for Requests for Alternatives I4R-17, I4R-23, ISI-05-018, I6R-10Hydrostatic
Incorporated by reference
ML22041B53610 February 2022NRR E-mail Capture - Constellation Energy Generation, LLC - Request for Additional Information Regarding Fleet License Amendment Request to Adopt TSTF-541
ML21308A5594 November 2021NRR E-mail Capture - NRC Request for Additional Information for Ginna Biennial EP Exercise Exemption RequestExemption Request
ML21256A19010 September 2021NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding License Transfer Application
ML21189A1608 July 2021NRR E-mail Capture - Request for Additional Information - Braidwood, Byron, and Ginna - Amendment to Address the Issues in Westinghouse NSALsAnticipated operational occurrence
ML21144A21324 May 2021NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding License Transfer Application
ML21119A10827 April 2021Ti 2515/194 Inspection Documentation RequestOpen Phase Condition
Time Critical Operator Action
ML21076A51517 March 2021R. E. Ginna Nuclear Power Plant - RAI Steam Generator LAR to Revise Technical Specifications for Steam Generator Tube Inspection Frequency (EPID L-2020-LLA-0207) (e-mail)
ML21062A0651 March 2021NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding Proposed Fleet Alternative to Documentation Requirements for Pressure Retaining BoltingIncorporated by reference
ML21049A25718 February 2021Request for Additional Information Byron/Dresden Proposed Changes to Site Emergency Plans to Support Post-Shutdown and Permanently Defueled Conditions (EPID-2020-LLA-0240 & EPID-2020-LLA-0237)
ML21029A33029 January 2021NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding Fleet Alternative Request to Use ASME Code Case N-885
ML20357A22317 December 2020Update on Ginna POV - 3504A and 4562 (Email Request for Inspection Information)
ML20218A6425 August 2020R. E. Ginna Nuclear Power Plant - Request for Additional Information (RAI) for LAR to Implement WCAP, TSTF-411, and TSTF-418High winds
Internal Flooding
Probabilistic Risk Assessment
ML20153A7041 June 2020NRR E-mail Capture - Preliminary RAI for Fleet Request to Use Alternative OMN-26Incorporated by reference
ML19120A38630 April 2019Request for Additional Information to Revise Emergency Plan Response Organization Staffing and AugmentationMinimum staff
ML18228A52415 August 2018R. E. Ginna Nuclear Power Plant - TSTF 547 Adoption, Request for Additional Information (RAI) EPID L-2018-LLA-0179
ML18102A23712 April 2018NRR E-mail Capture - Calvert Cliffs, Ginna, and Nine Mile Point - Request for Additional Information Regarding License Amendment Request to Revise Emergency Action Level Schemes (EPID-L-2017-LLA-0237)
ML18067A1488 March 2018Enclosurequest for Additional Information (Letter to P. R. Simpson Request for Additional Information Regarding Exelon Generating Company, Llc'S Decommissioning Funding Plan Update for Independent Spent Fuel Storage Installation)Decommissioning Funding Plan
Authorized possession limits
ML17331B13412 December 20172, and R.E. Ginna Nuclear Power Plant - Request for Additional Information - RegardingOperating Basis Earthquake
Earthquake
Fuel cladding
ML17277A2052 October 2017Email - Ginna: Request for Additional Information (RAI) for NFPA-805 LARProbabilistic Risk Assessment
RS-17-026, Response to March 12, 2012, Request for Information Enclosure 2, Recommendation 2.1, Flooding, Required Response 3, Flooding Focused Evaluation Summary Submittal10 March 2017Response to March 12, 2012, Request for Information Enclosure 2, Recommendation 2.1, Flooding, Required Response 3, Flooding Focused Evaluation Summary SubmittalHydrostatic
FLEX
Fukushima Dai-Ichi
Flooding Focused Evaluation
ML17062A4913 March 2017NRR E-mail Capture - Exelon Generation Company, LLC - Request for Additional Information Regarding Fleet Alternative to RPV Threads in Flange Examination (CAC Nos. MF8712-MF8729)
ML16278A0777 November 2016Request for Additional Information Regarding: Deletion of E Bar Definition and Revision to Reactor Coolant System Specific Activity Technical SpecificationsUnanalyzed Condition
ML16075A11917 March 2016Request for Additional Information Regarding: Deletion of E Bar Definition and Revision to Reactor Coolant System Specific Activity Technical SpecificationsUnanalyzed Condition
ML16077A10817 March 2016NRR E-mail Capture - (External_Sender) Email Clarification and Supplementation to AMP RAI
ML15344A3537 January 2016Request for Additional Information Regarding Risk-Informed Technical Specifications Initiative 5B CAC No. MF6358)Internal Flooding
Probabilistic Risk Assessment
Surveillance Frequency Control Program
Large early release frequency
ML15349B0257 January 2016Request for Additional Information Regarding Reactor Vessels Internals ProgramAging Management
Power change
ML15100A21128 April 2015RAI Regarding License Amendment Request to Adopt Technical Specification Task Force Traveler-523
ML14093A6771 May 2014SONGS - Request for Additional Information Concerning Pre-Emption AuthorityPreemption Authority
ML13337A6255 December 2013Constellation Energy Nuclear Group, R.E. Ginna Nuclear Power Plant, Interim Staff Evaluation and Request for Additional Information Regarding the Overall Integrated Plan for Implementation of Order EA-12-051, Reliable Spent Fuel Pool InstruHigh Radiation Area
Safe Shutdown Earthquake
Cyber Security
Spent Fuel Pool Instrumentation
Fire Protection Program
Coast down
ML13337A3905 December 2013Request for Additional Information Regarding Order Approving Direct Transfer of Renewed Facility Operating License and Conforming Amendments
ML13304B4181 November 2013Request for Additional Information Associated with Near-Term Task Force Recommendation 2.3, Seismic Walkdowns
ML13261A06124 September 2013R. E. Ginna Nuclear Power Plant - Request for Additional Information Regarding Amendment to Revise Technical Specification 3.6.5. Containment Air Temperature.
ML13261A11412 September 2013R. E. Ginna Nuclear Power Plant, E-mail Re. NFPA 805 License Amendment Request, Audit RAIsSafe Shutdown
Probabilistic Risk Assessment
Thermoset
Large early release frequency
Hemyc
Earthquake
Fire Protection Program
ML13226A38229 August 2013Request for Additional Information Overall Integrated Plan for Reliable Spent Fuel Pool Instrumentation (Order EA-12-051)High Radiation Area
FLEX
Spent Fuel Pool Instrumentation
ML13108A06823 April 2013(Security Related) Request for Additional Information for Review of Security Plan Changes in Revision 5
ML12264A61920 September 2012RAI for the CRDM Nozzle Examination Relief RequestBoric Acid
ML12234A51721 August 2012Physical Security Plan Change Per 10 CFR 50.54(p)(2)
ML12228A61815 August 2012Re_ Ginna-BMI Flaw Evaluation(ME8247)
ML12178A19225 June 2012Gina_ TAC Nos. ME8000 and ME8001-Relief Ginna Relief Request
ML12056A04812 March 2012Enclosure 2 - Recommendation 2.1: FloodingHigh winds
Ultimate heat sink
Probabilistic Risk Assessment
Fukushima Dai-Ichi
Earthquake
ML12056A04712 March 2012Enclosure 1 - Recommendation 2.1: SeismicHigh winds
Safe Shutdown Earthquake
Probabilistic Risk Assessment
Fukushima Dai-Ichi
Large early release frequency
Earthquake
Generic Issues Program
ML12056A05012 March 2012Enclosure 4 - Recommendation 2.3: FloodingUnanalyzed Condition
High winds
Probabilistic Risk Assessment
Fukushima Dai-Ichi
Earthquake
ML12056A04912 March 2012Enclosure 3 - Recommendation 2.3: SeismicUnanalyzed Condition
Ultimate heat sink
Safe Shutdown Earthquake
Fukushima Dai-Ichi
Earthquake
ML12056A05112 March 2012Enclosure 5 - Recommendation 9.3: Emergency PreparednessFukushima Dai-Ichi
Earthquake
ML12012012723 January 2012Request for Additional Information the 2011 Steam Generator Tube Inspections - R.E. Ginna Nuclear Power Plant
ML11284019912 October 2011Transmittal Letter, Request for Additional Information (NON-PROPRIETARY) Proposed Merger Between Exelon Corporation and Constellation Energy Group, Inc.Decommissioning Funding Plan