Request for Additional Information Regarding Reactor Vessels Internals Program
ML15349B025
Person / Time
Site: Ginna Constellation icon.png
Issue date: 01/07/2016
From: Render D
Plant Licensing Branch 1
To: Bryan Hanson
Exelon Nuclear
Diane Render, NRR/DORL
References
CAC MF6713
Download: ML15349B025 (4)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 Mr. Bryan C. Hanson President and Chief Nuclear Officer Exelon Nuclear R. E. Ginna Nuclear Power Plant 4300 Winfield Road Warrenville, IL 60555 January 7, 2016

SUBJECT:

R.E. GINNA NUCLEAR POWER PLANT - REQUEST FOR ADDITIONAL INFORMATION REGARDING REACTOR VESSELS INTERNALS PROGRAM (CAC NO. MF6713)

Dear Mr. Hanson:

On September 28, 2012, Constellation Energy Nuclear Generation Group (now operating as Exelon Generation Company, LLC, the licensee) submitted the document titled "Reactor Vessels Internals Program," based on the Electric Power Research Institute Report MRP-227, Revision 0, for the U.S. Nuclear Regulatory Commission (NRC) staff review and approval.

The NRC staff is reviewing the submittal and has determined that additional information is needed to complete its review. The specific questions are found in the enclosed request for additional information (RAI). On December 10, 2015, Exelon staff indicated that a response to the RAI would be provided by February 11, 2016.

Please contact me at (301) 415-3629 if you have any questions on this request.

Docket No. 50-244

Enclosure:

As stated cc w/encl: Listserv

~(___

Dia e ender, Project Manager Plant Licensing Branch 1-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation

REQUEST FOR ADDITIONAL INFORMATION REGARDING AGING MANAGEMENT PROGRAM FOR THE REACTOR VESSEL INTERNALS EXELON GENERATION COMPANY, LLC R. E. GINNA NUCLEAR POWER PLANT, LLC DOCKET NO. 50-244 In a letter dated September 28, 2012, Constellation Energy Nuclear Generation Group (now operating as Exelon Generation Company, LLC, the licensee) submitted an aging management program (AMP) for the reactor vessel internals (RVI) at R.E. Ginna Nuclear Power Plant (Ginna). The NRC staff is reviewing Ginna's AMP report and based on the review conducted, the staff has developed the following request for additional information (RAI). The MRP-227 report, "Pressurized Water Reactor (PWR) Internals Inspection and Evaluation Guidelines," and its supporting reports were used as technical bases for developing Ginna's AMP.

RAI 1: The MRP-2013-025, "MRP-227-A Applicability Template Guidelines," (Agencywide Documents Access and Management System Accession No. ML13322A454) report identifies two additional issues that all Combustion Engineering, Inc. and Westinghouse design plants referencing topical report MRP-227-A must address to close Applicant/Licensee Action Item 1 related to plant-specific applicability of the topical report. The staff therefore requests the following information:

1. Do the Ginna RVI components have non-weld or bolting austenitic stainless steel components with 20% cold work or greater? If so, do the affected components have operating stresses greater than 30 ksi? The licensee can apply "Option 1" or "Option 2,"

as addressed in Appendix A of the MRP-2013-025 report. If "Option 2" is applicable to Ginna, the licensee should list plant-specific RVI components that have been exposed to cold work equal to or greater than 20%.

2. Has Ginna ever utilized atypical design or fuel management that could make the assumptions of MRP-227-A regarding core loading/core design non-representative for that plant, including power changes/uprates? The licensee is requested to use MRP-2013-025 and apply "Option 1" or "Option 2," as addressed in Appendix B of the report. If Option 1 is used, the following plant-specific values should be submitted:

Enclosure (a) Active fuel to upper core plate distance; (b) Average core power density; and (c) Heat generation figure of merit.

RAI 2: Historically, the following materials used in the PWR RVI components were known to be susceptible to some of the aging degradation mechanisms that are identified in the MRP-227-A report. In this context, the NRC staff requests that the licensee confirm that these materials are not currently used in the RVI components at Ginna. This RAI is applicable to the components classified under "Primary," or "Expansion," or "Existing," categories in MRP-227-A report.

(1) Nickel base alloys-lnconel 600; Weld Metals-Alloy 82 and 182 and Alloy X-750 (excluding control rod guide tube split pins)

(2) Alloy A-286 ASTM A 453 Grade 660, Condition A or B (3) Stainless steel type 347 material (excluding baffle-former bolts, and, barrel former bolts)

( 4) Precipitation hardened stainless steel materials-17-4 and 15-5 (5) Type 431 stainless steel material

Mr. Bryan C. Hanson President and Chief Nuclear Officer Exelon Nuclear R. E. Ginna Nuclear Power Plant 4300 Winfield Road Warrenville, IL 60555 January 7, 2016

SUBJECT:

RE. GINNA NUCLEAR POWER PLANT - REQUEST FOR ADDITIONAL INFORMATION REGARDING REACTOR VESSELS INTERNALS PROGRAM (CAC NO. MF6713)

Dear Mr. Hanson:

On September 28, 2012, Constellation Energy Nuclear Generation Group (now operating as Exelon Generation Company, LLC, the licensee) submitted the document titled "Reactor Vessels Internals Program," based on the Electric Power Research Institute Report MRP-227, Revision 0, for the U.S. Nuclear Regulatory Commission (NRC) staff review and approval.

The NRC staff is reviewing the submittal and has determined that additional information is needed to complete its review. The specific questions are found in the enclosed request for additional information (RAI). On December 10, 2015, Exelon staff indicated that a response to the RAI would be provided by February 11, 2016.

Please contact me at (301) 415-3629 if you have any questions on this request.

Docket No. 50-244

Enclosure:

As stated cc w/encl: Listserv DISTRIBUTION:

PUBLIC LPL 1-1 Reading File RidsNrrDorlDpr Sincerely, IRA/

Diane Render, Project Manager Plant Licensing Branch 1-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation RidsNrrDorlLpl 1-1 RidsNrrLAKGoldstein RidsRgn1 MailCenter RidsNrrPMREGinna RidsACRS_MailCTR JMcHale A DAMS A ccess1on N ML 153 98025 o.: