Letter Sequence RAI |
|---|
EPID:L-2022-LLA-0030, International, Submittal of License Amendment Request 9375-1 for the HI-STAR Atb 1T Non-Fuel Waste Transport System (Approved, Closed) |
Initiation
- Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request, Request
- Acceptance, Acceptance
- Supplement, Supplement, Supplement, Supplement
Results
Other: ML22287A139, ML22287A141, ML22287A143, ML22287A146, ML22334A262, ML22334A263, ML22335A499, ML22335A501, ML22343A261, ML23068A377, ML23129A797, ML23206A199, ULNRC-06783, Enclosure 2: Affidavit for Withholding, ULNRC-06808, Affidavit
|
MONTHYEARML22050A0012022-02-18018 February 2022 International, Submittal of License Amendment Request 9375-1 for the HI-STAR Atb 1T Non-Fuel Waste Transport System Project stage: Request ML22130A7052022-05-10010 May 2022 International - Resubmittal of License Amendment Request 9375-1 for the HI-STAR Atb 1T Non-Fuel Waste Transport System Project stage: Request ML22161A0582022-06-0909 June 2022 International, Modification of License Amendment Request 9375-1 for the HI-STAR Atb 1T Non-Fuel Waste Transport System Project stage: Request ML22161A0592022-06-0909 June 2022 International, Modification of License Amendment Request 9375-1 for the HI-STAR Atb 1T Non-Fuel Waste Transport System Project stage: Request ML22235A1152022-08-25025 August 2022 Enc - 9375 RAI 2022 Project stage: RAI ML22235A1132022-08-25025 August 2022 RAIs for the Model No. HI-STAR Atb 1T Package Project stage: Request ML22235A1142022-08-25025 August 2022 Letter - Request for Additional Information for the Review of the Atb 1T Package - 2022 Project stage: RAI ML22285A1152022-10-0707 October 2022, 12 October 2022 Application for Technical Specification Change and Exemption Request Regarding Use of Framatome Gaia Fuel (LDCN 22-0002) Project stage: Request ML22285A1222022-10-12012 October 2022 Attachment 5 to Enclosure 1: ANP-3947NP, Callaway Unit 1 License Amendment Request Inputs for Use of Framatome Fuel, Revision 3, Dated October 2022 Project stage: Request ML22285A1252022-10-12012 October 2022 Attachment 8 to Enclosure 1: ANP-3969NP, Callaway Non-LOCA Summary Report, Revision 2, Dated October 2022 Project stage: Request ML22285A1232022-10-12012 October 2022 Attachment 6 to Enclosure 1: ANP-3944NP, Callaway Realistic Large Break LOCA Analysis with Gaia Fuel Design, Revision 1, Dated October 2022 Project stage: Request ML22285A1242022-10-12012 October 2022 Attachment 7 to Enclosure 1: ANP-3943NP, Callaway Small Break LOCA Analysis with Gaia Fuel Design, Revision 1, Dated October 2022 Project stage: Request ML22287A1392022-10-14014 October 2022 Responses to HI-STAR Atb 1T Requests for Additional Information Project stage: Other ML22287A1462022-10-14014 October 2022 Affidavit of Kimberly Manzione Project stage: Other ML22287A1382022-10-14014 October 2022 Responses to HI-STAR Atb 1T Requests for Additional Information Project stage: Request ML22287A1412022-10-14014 October 2022 Attachment 2 - HI-STAR Atb 1T Amendment Request 1 RAI Responses Project stage: Other ML22287A1432022-10-14014 October 2022 Attachment 4 - Safety Analysis Report on the HI-STAR Atb 1T Non-Fuel Waste Transport System Project stage: Other ML22305A6042022-11-0101 November 2022 International - Supplemental Information for Responses to HI-STAR Atb 1T Requests for Additional Information Project stage: Supplement ML22335A5012022-11-16016 November 2022 Enclosure 3: ANP-4012NP, Revision 1, Callaway Rod Ejection Accident Analysis Project stage: Other ULNRC-06783, Enclosure 2: Affidavit for Withholding2022-11-16016 November 2022 Enclosure 2: Affidavit for Withholding Project stage: Other ML22335A4992022-11-16016 November 2022 Enclosure 1: Responses to Requested Information Project stage: Other ML22335A4972022-11-16016 November 2022, 1 December 2022 Supplement to License Amendment and Exemption Request Regarding Use of Framatome Gaia Fuel (LDCN 22-0002) Project stage: Request ML22322A0062022-11-17017 November 2022 NRR E-mail Capture - Final - LIC-109 Acceptance Review (Unacceptable for Review with Opportunity to Supplement) Callaway - LAR for Proposed Changes to TS and Exemption Request Use of Framatome Gaia Fuel - L-2022-LLA-0150 & L-2022-LLE-0030 Project stage: Acceptance Review ML22335A4982022-12-0101 December 2022 Supplement to License Amendment and Exemption Request Regarding Use of Framatome Gaia Fuel (LDCN 22-0002) Project stage: Supplement ML22343A2612022-12-0909 December 2022 International - Submittal of Final SAR for HI-STAR ATB-1T Amendment 1 Project stage: Other ML22334A2632022-12-13013 December 2022 Enclosure 1 - Certificate of Compliance Rev. No. 1 Project stage: Other ML22334A2622022-12-13013 December 2022 Cover letter- Certificate of Compliance No. 9375, Revision No. 1, for the Model No. HI-STAR ATB1T Package Project stage: Other ML22334A2612022-12-13013 December 2022 Certificate of Compliance No. 9375, Revision No. 1, for the Model No. HI-STAR ATB1T Package Project stage: Request ML22334A2642022-12-13013 December 2022 Enclosure 2 - Safety Evaluation Report Project stage: Approval ML22348A1162022-12-21021 December 2022 Acceptance of Requested Licensing Actions Application for License Amendment & Regulatory Exemptions for TS Change & Exemption Request Regarding Use of Framatome Gaia Fuel (EPID L-2022-LLA-0150 & EPID L-2022-LLE-0030) Project stage: Acceptance Review ML23068A3772023-03-20020 March 2023 Regulatory Audit Plan and Setup of Online Reference Portal for License Amendment Request and Exemption for Fuel Transition to Framatome Gaia Fuel (EPID L-2022-LLA-0150 and EPID L-2022-LLE-0030) - Nonproprietary Project stage: Other ML23107A1812023-04-17017 April 2023 NRR E-mail Capture - Regulatory Audit Questions - Callaway LAR and Exemption for Fuel Transition to Framatome Gaia Fuel - EPIDs - L-2022-LLA-0150 and L-2022-LLE-0030 Project stage: Approval ML23114A2302023-04-24024 April 2023 NRR E-mail Capture - Regulatory Audit Question - Callaway LAR and Exemption for Fuel Transition to Framatome Gaia Fuel - EPIDs - L-2022-LLA-0150 and L-2022-LLE-0030 Project stage: Approval ULNRC-06808, Affidavit2023-04-27027 April 2023 Affidavit Project stage: Other ML23129A7932023-04-27027 April 2023, 9 May 2023 Post-Audit Supplement to License Amendment Request and Exemption to Allow Use of Framatome Gaia Fuel (LDCN 22-0002) (Iepid L-2022-LLA-0150 and EPID L-2022-LLE-0030) Project stage: Request ML23118A3492023-05-0808 May 2023 Request for Withholding Information from Public Disclosure Project stage: Withholding Request Acceptance ML23129A7942023-05-0909 May 2023 Post-Audit Supplement to License Amendment Request and Exemption to Allow Use of Framatome Gaia Fuel (LDCN 22-0002) (Iepid L-2022-LLA-0150 and EPID L-2022-LLE-0030) Project stage: Supplement ML23129A7972023-05-0909 May 2023 Response to Audit Questions Project stage: Other ULNRC-06821, Post-Audit Follow-Up Information in Support of Callaways License Amendment Request and Proposed Exemption to Allow Use of Framatome Gaia Fuel (LDCN 22-0002) (EPID L-2022-LLA-0150 and EPID L-2022-LLE-00301)2023-06-21021 June 2023 Post-Audit Follow-Up Information in Support of Callaways License Amendment Request and Proposed Exemption to Allow Use of Framatome Gaia Fuel (LDCN 22-0002) (EPID L-2022-LLA-0150 and EPID L-2022-LLE-00301) Project stage: Request ML23215A1962023-08-0303 August 2023, 31 August 2023 Supplement to License Amendment and Exemption Request Regarding Use of Framatome Gaia Fuel (LDCN 22-0002) Project stage: Request ML23215A1972023-08-0303 August 2023 Supplement to License Amendment and Exemption Request Regarding Use of Framatome Gaia Fuel (LDCN 22-0002) Project stage: Supplement ULNRC-06829, Affidavit2023-08-0303 August 2023 Affidavit Project stage: Request ML23219A1392023-08-15015 August 2023 Request for Withholding Information from Public Disclosure Project stage: Withholding Request Acceptance ML23215A1992023-08-31031 August 2023 ANP-4012NP, Callaway, Unit 1, Rod Ejection Accident Analysis Revision 2, August 2023 Project stage: Request ML23206A1992023-09-15015 September 2023 Regulatory Audit Summary Regarding License Amendment and Regulatory Exemptions Request for Fuel Transition to Framatome Gaia Fuel (Epids L-2022-LLA-0150 and L-2022-LLE-0030) Project stage: Other ML23234A1522023-10-0505 October 2023 Exemption from the Requirements of 10 CFR Part 50, Section 50.46, and Appendix K Regarding Use of M5 Cladding Material (EPID L-2022-LLE-0030) (Letter) Project stage: Approval ML23234A1532023-10-0505 October 2023 Exemption from the Requirements of 10 CFR Part 50, Section 50.46, and Appendix K Regarding Use of M5 Cladding Material (EPID L-2022-LLE-0030) (Exemption) Project stage: Approval ML23234A1542023-10-11011 October 2023 Exemption from the Requirements of 10 CFR Part 50, Section 50.46, and Appendix K Regarding Use of M5 Cladding Material (EPID L-2022-LLE-0030) (FRN) Project stage: Approval 2022-08-25
[Table View] |
Text
Enclosure Request for Additional Information Docket No. 71-9375 Model No. HI-STAR ATB 1T Package By letter dated June 9, 2022 (Agencywide Documents Access and Management System
[ADAMS] Accession No. ML22161A058), Holtec International (Holtec) submitted an amendment request for the Model No. HI-STAR ATB 1T package. Holtec proposed an alternative high strength material to be added as an optional material of construction for the HI-STAR ATB 1T containment boundary.
This request for additional information (RAI) identifies information needed by the staff in connection with its review of the application.
Each individual RAI describes information needed by the staff to complete its review of the application and to determine whether the applicant has demonstrated compliance with the regulatory requirements of Title 10 of the Code of Federal Regulations (10 CFR) Part 71.
CHAPTER 2 MATERIALS REVIEW:
2-1 Justify the use of materials specifications and their properties for the ITS HI-STAR ATB 1T containment boundary that are not included as permissible materials for ASME Section III Subsection NB.
SAR Section 1.2 Description of Packaging Components and Their Design & Operational Features states, The governing Code for the design of the Containment Boundary of HI-STAR ATB 1T is ASME Code Subsection NB [1.2.1] which has well-articulated rules for plate & shell type structures operating under ambient conditions. SAR Table 2.1.7:
Applicable Codes and Standards for the Materials Procured/Fabricated for the HI-STAR ATB 1T Packaging specifically cites ASME Code Section III Subsection NB for the containment boundary components. SAR Section 4.1, Containment Boundary, the applicant states that, The containment boundary system components for the HI-STAR ATB 1T system are designed and fabricated in accordance with the requirements of ASME Code,Section III, Subsection NB.
However, the HI-STAR ATB 1T design proposes to use two materials that are not approved as permissible materials for ASME Section III Class 1 construction, SA-508 Class 4N Grade 2, and ASTM A514. In ASME BPV Code Section III, 2013 Edition, there is no entry for SA-508 4N Class 2. While SA-508 4N, Class 2 is included in the 2021 edition, per Table 2A, it is not permitted for use in Section III. ASTM A514 has not been incorporated into the ASME B&PV code as a permissible material for any Section III or Section VIII component. Consequently, the ASME code does not include values of tensile strength, yield strength, design stress and design stress intensity as a function of temperature.
In addition, for thickness greater than 2.5, the ASTM specification for A514 specifies a minimum tensile strength of 100 ksi. The staff notes that the HI-STAR ATB 1T containment baseplate is greater than 2.5 thick. Table 2.2.1A of Enclosure 3, lists the Su as 105 ksi.
The staff requests the applicant to address this discrepancy in the application with Subsection NB and with the ASTM specification with the values in Table 2.2.1A to account for the material properties of a HI-STAR ATB 1T containment baseplate manufactured using ASTM A514.
This information is requested by the staff to demonstrate compliance with 10 CFR 71.31(c), 71.33(a) and 71.51(a).
2-2 Provide the material properties of welds used in modeling of the containment boundary or provide a justification for why the properties of the welds do not need to be explicitly considered.
In Enclosure 6, Section 3.6 states, Trivial simplifications and approximations are considered in the finite element model as follows, without compromising the quality and accuracy of the simulation model: 1. The welded connections between the containment walls and the baseplates are explicitly represented in the FE model by distinct parts. For conservatism, the analytical (FE) model considers the SS-308 weld material properties to develop the true-stress-vs-strain curve.
The staff notes that a true-stress true-strain curve was developed for the Type 308 weld filler metal in Enclosure 6 Appendix A. The ATB 1B 308 weld metal would be representative of the welded connections for the Type 304 Stainless Steel Dose Blocker Plates which serve as a shielding component but not for the welds for the ferritic steel containment boundary, which have different material procurement and NDE acceptance criteria.
The containment boundary is to be manufactured using ferritic steels including ASTM A514, or ASME SA-517 or ASME SA-508 Class 4N Grade 2. It is not clear whether the mechanical properties of the containment boundary welds were specifically considered but Enclosure 6 does not contain true-stress true-strain curves for the containment boundary welds.
This information is requested by the staff to demonstrate compliance with 10 CFR 71.31(c), 71.33(a) and 71.51(a).