Post Office Box 2000, Decatur, Alabama 35609-2000 May 1, 2023 10 CFR 50.4 10 CFR 50.36 §a 10 CFR 50 Appendix I ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Browns Ferry Nuclear Plant, Units 1, 2, and 3 Renewed Facility Operating License Nos. DPR-33, DPR-52, and DPR-68 NRC Docket Nos. 50-259, 50-260, and 50-296
Subject:
2022 Annual Radioactive Effluent Release Report In accordance with the Browns Ferry Nuclear Plant (BFN), Units 1, 2, and 3, Technical Specification Section 5.6.3, the Tennessee Valley Authority is submitting the BFN Annual Radioactive Effluent Release Report for the period January through December 2022. This document is in conformance with Title 10 of the Code of Federal Regulations (10 CFR) 50.36a and 10 CFR 50, Appendix I, Section IV.B.1.
There are no new regulatory commitments contained in this letter. Should you have any questions concerning this submittal, please contact Chris Vaughn at (256) 729-2636.
Respectfully, M. Sivaraman Site Vice President
Enclosure:
2022 Annual Radioactive Effluent Release Report cc (w/ Enclosures):
NRC Regional Administrator - Region II NRC Senior Resident Inspector - Browns Ferry Nuclear Plant NRC Project Manager - Browns Ferry Nuclear Plant
ENCLOSURE Browns Ferry Nuclear Plant Units 1, 2, and 3 2022 Annual Radioactive Effluent Release Report See Enclosed
Browns Ferry Nuclear Plant Tennessee Valley Authority Annual Radioactive Effluent Release Report 2022
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Table of Contents I. Introduction .......................................................................................................................................... 4 II. Supplemental Information .................................................................................................................... 4 A. Regulatory Limits .............................................................................................................................. 4
- 1. Gaseous Effluents ......................................................................................................................... 4
- 2. Liquid Effluents ............................................................................................................................. 4 B. Limitation on Dose Rate .................................................................................................................... 4
- 1. Gaseous Effluents ......................................................................................................................... 4
- 2. Liquid Effluents ............................................................................................................................. 5 C. Average Energy ................................................................................................................................. 5 D. Measurements & Approximations of Total Radioactivity ................................................................. 5
- 1. Gaseous Effluents ......................................................................................................................... 5
- 2. Liquid Effluents ............................................................................................................................. 6 E. Batch Releases .................................................................................................................................. 7
- 1. Gaseous ......................................................................................................................................... 7
- 2. Liquid ............................................................................................................................................. 7 F. Abnormal Releases............................................................................................................................ 8
- 1. Gaseous ......................................................................................................................................... 8
- 2. Liquid ............................................................................................................................................. 8 G. Non-routine, Planned Discharges ..................................................................................................... 9 H. Radioactive Waste System Treatment Changes ............................................................................... 9 I. Land Use Census Changes ................................................................................................................. 9 J. Effluent Monitoring Instrument Inoperability > 30 Days .................................................................. 9 K. Effluent Monitoring Equipment Sample Deviation ........................................................................... 9 L. Offsite Dose Calculation Manual Changes ........................................................................................ 9 M. Groundwater Monitoring and Program (NEI 07-07) ................................................................... 10 N. Errata/Corrections to Previous ARERRs .......................................................................................... 12 III. Gaseous Effluents ........................................................................................................................... 13 IV. Liquid Effluents ............................................................................................................................... 20 V. Solid Waste Storage and Shipment..................................................................................................... 22 A. Solid Waste Shipped Off-site for Burial or Disposal (Not Irradiated Fuel) ...................................... 22 B. Irradiated Fuel Shipments (Disposition) ......................................................................................... 26 VI. Radiological Impact to Man ............................................................................................................ 27 Page 2 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report A. Introduction .................................................................................................................................... 27 B. Dose Limits ...................................................................................................................................... 27 C. Dose Calculations ............................................................................................................................ 28 D. Doses from Airborne Effluents........................................................................................................ 28 E. Doses from Liquid Effluents ............................................................................................................ 29 F. Population Doses ............................................................................................................................ 30 G. Offsite Direct Radiation Dose.......................................................................................................... 31 H. Dose to a Member of the Public Inside the Site Boundary ............................................................. 31 I. Total Dose ....................................................................................................................................... 32 J. Tables .............................................................................................................................................. 33 VII. Meteorological Data ....................................................................................................................... 39 Page 3 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report I. Introduction II. Supplemental Information A. Regulatory Limits
- 1. Gaseous Effluents Fission and Activation Gases The release of fission and activation gases is regulated by the dose limits of Title 10 of the Code of Federal Regulations (10 CFR) 50 Appendix I and Browns Ferry Nuclear Plant (BFN) Offsite Dose Calculation Manual (ODCM). The air dose to areas at and beyond the site boundary due to noble gases released in gaseous effluents per unit shall be limited during any calendar quarter to 5 millirad (mrad) for gamma radiation and 10 mrad for beta radiation; and during any calendar year to 10 mrad for gamma radiation and 20 mrad for beta radiation.
Iodines and Particulates with Half-Lives Greater than Eight Days The release of iodines and particulates in gaseous effluent is regulated by the dose limits of 10 CFR 50 Appendix I and the BFN ODCM. The dose to a member of the public from radioiodines, radioactive materials in particulate form, and radionuclides other than noble gases with half-lives greater than eight days in gaseous effluent released per unit to areas at and beyond the site boundary shall be limited to any organ during any calendar quarter to 7.5 millirem (mrem), and during any calendar year to 15 mrem.
- 2. Liquid Effluents The release of radioactive liquid effluents is regulated by the dose limits of 10 CFR 50 Appendix I and the BFN ODCM. The doses or dose commitment to a member of the public from radioactive materials in liquid effluents released from each unit to unrestricted areas shall be limited during any calendar quarter to 1.5 mrem to the total body and 5 mrem to any organ and during any calendar year to 3 mrem to the total body and 10 mrem to any organ.
B. Limitation on Dose Rate
- 1. Gaseous Effluents Fission and Activation Gases The instantaneous release rate of fission and activation gases is based on the dose rate limits of 10 CFR 20.1301 and the BFN ODCM. The dose rate at any time to areas at and beyond the site boundary due to noble gases released in gaseous effluents from the site shall be limited to 500 mrem per year to the total body and 3000 mrem per year to the skin.
The BFN ODCM Section 7.2 determines the maximum noble gas release rate.
Page 4 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Iodines and Particulates with Half-Lives Greater than Eight Days The instantaneous release rate of particulates and iodines is regulated by the dose rate limits of the BFN ODCM. The dose rate at any time to areas at and beyond the site boundary, due to I-131, I-133, H-3, and particulates with half-lives greater than eight days in gaseous effluent released from the site, shall be limited to 1500 mrem per year to any organ.
The BFN ODCM Section 7.3 determines the maximum particulate and iodine dose rates.
- 2. Liquid Effluents The concentration of radionuclides in liquid effluents released at any time from the site to unrestricted areas shall be limited to the concentrations specified in 10 CFR 20.1001-20.2402, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases.
For dissolved or entrained noble gases, the concentration shall be limited to 2E-4 Ci per milliliter (ml) total activity.
C. Average Energy The BFN ODCM limits the dose equivalent rates due to the release of noble gases to less than or equal to 500 mrem/year to the total body and less than or equal to 3000 mrem/year to the skin. The use of dose rate is in accordance with NUREG-0133, "Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants."
Since the release rate is not used for effluent control, the average beta and gamma energies (E) for gaseous effluents discussed in Regulatory Guide 1.21, "Measuring, Evaluation, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants," are not applicable and not included in this report.
D. Measurements & Approximations of Total Radioactivity Radioactivity measurements performed in support of the Browns Ferry Nuclear Plant ODCM meet the Lower Limit of Detection requirements given in ODCM Tables 2.2-1 and 2.2-2.
- 1. Gaseous Effluents Noble gases in the building vent and stack (elevated) gaseous effluents are continuously monitored. The flow rate of the stack is continuously monitored and the building vent effluent flow rates are calculated once a shift based on the configuration of operating exhaust fans. The vent flow is calculated for each release. Gas grab samples of the stack are taken and analyzed weekly. Gas grab samples of in-service vents are taken and analyzed monthly. The specific noble gas activity concentrations and total volume of the gases are used to calculate the total Curies of noble gases released.
In 2019, Browns Ferry revised noble gas sampling and analysis procedures which included sampling with a larger volume (1240 cc gas Marinelli) and analyzing for a longer count time (1000 seconds). Since this revision, the site has detected low levels of noble gases in the stack vent, which is expected.
Page 5 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report The tritium concentration is determined by the analysis of a monthly grab sample for each release point.
Iodines and particulates are continuously sampled on impregnated charcoal filters and particulate filters, respectively. The charcoal and particulate samples are replaced at least weekly and analyzed to determine specific activity concentrations. The specific activity concentrations and vent flow rate data are used weekly to verify that release rate limits were not exceeded. The specific activity concentrations and total volume of gaseous effluent are used on a monthly basis to determine the total curies of each particulate and iodine released during the month.
The gross alpha concentration is determined by analysis of a monthly particulate filter composite sample, and strontium-89 and strontium-90 are determined by analysis of a quarterly particulate filter composite sample for each release point.
Carbon-14 (C-14) production and gaseous waste effluent activity source term estimates were based on methodology provided in EPRI 1021106, Estimation of Carbon-14 in Nuclear Power Plant Gaseous Effluents, December 2010. C-14 gaseous activity and dose calculations are made using the following assumptions: (1) continuous release of the estimated C-14 generated for each unit during power operation based on the number of Effective Fuel Power Days (EFPD) for the period, (2) maximum C-14 activity from literature values cited in EPRI Report 1021106, and (3) typical fraction as carbon dioxide for gaseous releases from literature values also cited in EPRI Report 1021106.
In 2019, Browns Ferry updated C-14 production rate estimates utilizing the proxy methodology provided in EPRI Report 1021106. TVA documented this update in Updated Carbon-14 Production Rate Estimates for Gaseous Releases at TVA NPG Sites, October 2019. The C-14 releases increased in 2019 due to all three units completing Extended Power Uprate (EPU). The EPU for each unit increased the units MWth (Megawatt thermal) from 3,458 to 3,952 MWth. This increase in MWth is used in the calculation of C-14 releases. The increase in C-14 releases is expected.
- 2. Liquid Effluents The gamma ray emitting radionuclide concentrations are determined for each batch by gamma ray spectroscopy analysis of a grab sample. The allowable release rate is calculated for each batch based upon the known dilution flow. The flow rate of the liquid effluent is continuously monitored and the total volume released in each batch is determined. The total gamma activity released in each batch is determined by multiplying the radionuclide concentrations by the total volume discharged. The total gamma activity released during the month is then determined by summing the gamma activity content of each batch discharged during the month.
The gross alpha and tritium concentrations are measured on a monthly composite sample. The strontium-89, strontium-90, and iron-55 are measured on a quarterly composite sample.
Page 6 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report E. Batch Releases
- 1. Gaseous 1st 2nd 3rd 4th Units Total Quarter Quarter Quarter Quarter
- 1. Gaseous
- 1. Number of Batch 2 1 1 1 5 Releases
- 2. Total duration of minutes 9.60+01 4.80+01 4.80E+01 4.80E+01 2.40+02 batch releases
- 3. Maximum batch minutes 4.80E+01 4.80E+01 4.80E+01 4.80E+01 4.80E+01 release duration
- 4. Average batch minutes 4.80E+01 4.80E+01 4.80E+01 4.80E+01 4.80E+01 release duration
- 5. Minimum batch minutes 4.80E+01 4.80E+01 4.80E+01 4.80E+01 4.80E+01 release duration
- 2. Liquid 1st 2nd 3rd 4th Units Total Quarter Quarter Quarter Quarter
- 1. Liquids
- 1. Number of Batch 36 6 0 11 53 Releases
- 2. Total duration of minutes 1.04E+04 6.35E+03 0.00E+00 3.23E+03 2.00E+04 batch releases
- 3. Maximum batch minutes 6.55E+02 1.44E+03 0.00E+00 4.80E+02 1.44E+03 release duration
- 4. Average batch minutes 2.89E+02 1.06E+03 0.00E+00 2.94E+02 3.77E+02 release duration
- 5. Minimum batch minutes 2.30E+02 7.20E+02 0.00E+00 2.30E+02 2.30E+02 release duration
- 6. Avg stream flow during periods of release of liquid CFS 8.97E+04 2.49E+04 2.87E+04 4.09E+04 NA effluent into a flowing stream Page 7 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report F. Abnormal Releases
- 1. Gaseous Abnormal gaseous tritium releases occurred in 2022 from the Auxiliary Boiler System when the boilers were in service for unit outages. The identified source of tritium to the auxiliary boiler system is main steam leak-by from degraded Steam Jet Air Ejector (SJAE) / Auxiliary Boiler valves to the auxiliary boiler header (CR 1508177). At the Beginning of 2022, these valves were scheduled to be replaced during each units respective outage, with Unit 2 valves to be completed in Spring 2023.
1st 2nd 3rd 4th Units Total Quarter Quarter Quarter Quarter
- 1. Gaseous
- 1. Number of 3 2 0 0 5 abnormal Releases
- 2. Total Activity for Ci 1.39E-01 1.96E-03 0.00E+00 0.00E+00 1.41E-01 abnormal releases
- 2. Liquid Abnormal liquid tritium releases occurred throughout 2022 from Unit 1, Unit 2, and Unit 3 Station Sumps (CR 1508177). Plant station sumps are auto pumped to unit specific Condenser Circulating Water (CCW) discharge and subsequently to the Tennessee River. Identified sources include main steam leak-by from degraded SJAE / Auxiliary boiler system valves to Unit 1 Station Sump, Vacuum Priming system and multiple steam leaks in the SJAE and Offgas Recombiner rooms. Stations sumps will be added to the next ODCM revision as a permitted continuous liquid release point (CR 1721451).
1st 2nd 3rd 4th Units Total Quarter Quarter Quarter Quarter
- 1. Liquids
- 1. Number of 3 1 0 1 5 abnormal Releases
- 2. Total Activity for Ci 2.47E-01 2.59E-01 0.00E+00 1.92E-03 5.08E-01 abnormal releases Page 8 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report G. Non-routine, Planned Discharges In calendar year 2022 there were no non-routine planned discharges.
H. Radioactive Waste System Treatment Changes In calendar year 2022 there were no changes to the radwaste system or the process control program (PCP).
I. Land Use Census Changes In calendar year 2022 there were no changes to the land use census.
J. Effluent Monitoring Instrument Inoperability > 30 Days In calendar year 2022 there were no effluent monitoring instruments inoperable greater than 30 days.
K. Effluent Monitoring Equipment Sample Deviation In calendar year 2022 there were no effluent monitoring equipment sample deviations.
L. Offsite Dose Calculation Manual Changes In calendar year 2022 there were no changes to the Offsite Dose Calculation Manual.
Page 9 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report M. Groundwater Monitoring and Program (NEI 07-07)
In 2007, the Nuclear Energy Institute (NEI) established the Groundwater Protection Initiative (GPI), NEI 07-07. The Groundwater Protection Initiative was established to 1) improve management of situations involving inadvertent radiological releases that get into groundwater and 2) to improve communication with external stakeholders to enhance trust and confidence on the part of local communities, States, the NRC, and the public in the nuclear industrys commitment to a high standard of public radiation safety and protection of the environment. This section provides information and sample results from on-site groundwater locations that were sampled in support of the Groundwater Protection Initiative at Browns Ferry Nuclear Plant. The groundwater wells described in this section are not part of the Radiological Environmental Monitoring Program (REMP).
In the early 2000s, BFN initiated a groundwater study to identify the source of low-level tritium detected on-site. Results from the groundwater study (Investigation of Tritium Releases to Groundwater, 2006), suggest the source of tritiated groundwater was from historical leaks and spills associated with Radwaste/Condensate transfer tunnel.
Groundwater and surface water level measurements during the study indicated the return channel and subsequently the Tennessee River will ultimately be recipient to tritiated groundwater discharge from the site. It has been determined that there are no groundwater wells onsite or within 2-miles of the site that are used as a source of drinking water.
Groundwater movement in the area has been determined to be from the plant site toward the Tennessee River.
On-site groundwater monitoring was performed in 2022. The purpose of on-site groundwater monitoring is to ensure timely detection of inadvertent radiological releases to groundwater. Non-REMP groundwater wells monitor for potential leaks from plant equipment. As part of the GPI, BFN monitored a total of 30 groundwater wells located in the protected area and the owner-controlled area during 2022. Normal sampling frequencies are quarterly and semiannually with some wells sampled monthly if certain criteria are met or for investigation purposes. Samples are routinely analyzed for environmental level tritium (H-3) and principal gamma emitters (PGE) with selected wells analyzed for Hard-to-Detect (HTD) radionuclides (Gross Alpha, Fe-55, Ni-63, Sr-89, and Sr-90). In support of the groundwater program, the site also monitors recapture and on-site storm drains, catch basins and surface water.
In 2022, low levels of tritium were detected in on-site groundwater wells as indicated in Table 10, Groundwater Data. Table 10 demonstrates all on-site groundwater wells that indicated detectable tritium concentrations. Tritium concentrations in 2022 ranged from non-detectable, less than 196 pCi/L, up to a maximum concentration of 7,100 pCi/L (MW-1).
BFN has been monitoring a legacy tritium plume in the vicinity of groundwater well Dewat-A located adjacent to the reactor building. This plume is the result of previous leaks in past years (2015 and 2016). No other plant related radionuclides were detected in any groundwater well. There were no instances of any on-site spills or leaks that occurred during 2022 reporting period that were communicated to off-site agencies or that met the criteria in NEI 07-07, Appendix A.
Page 10 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Table 10 - Groundwater Data Tritium Activity Tritium Activity Sample Date Well ID Sample Date Well ID (pCi/L) (pCi/L) 1st Quarter 2021 2nd Quarter 2021 2/8/2022 Dewat-A 3690 5/12/2022 Dewat-A 1090 2/8/2022 MW-01 7100 5/12/2022 MW-01 390 2/8/2022 MW-02 1240 5/12/2022 MW-02 632 2/9/2022 MW-03 1140 5/10/2022 MW-03 478 2/8/2022 MW-04 5430 5/10/2022 MW-04 324 2/8/2022 MW-07 2080 5/10/2022 MW-07 2100 2/8/2022 MW-08 1900 5/10/2022 MW-08 1990 2/8/2022 MW-08i 414 5/10/2022 MW-08i 290 2/8/2022 MW-09 291 5/10/2022 MW-09 213 2/8/2022 MW-15 250 5/10/2022 MW-19 759 2/8/2022 MW-18 251 2/9/2022 MW-19 439 3rd Quarter 2021 4th Quarter 2021 8/10/2022 Dewat-A 693 11/7/2022 Dewat-A 803 8/9/2022 MW-01 386 11/10/2022 MW-01 1480 8/10/2022 MW-02 816 11/10/2022 MW-02 699 8/9/2022 MW-03 409 11/10/2022 MW-02i 387 8/9/2022 MW-07 1530 11/10/2022 MW-03 315 8/9/2022 MW-08 1040 11/10/2022 MW-04 514 8/9/2022 MW-08i 330 11/9/2022 MW-07 1120 8/9/2022 MW-19 330 11/10/2022 MW-08 417 11/10/2022 MW-08i 402 11/9/2022 MW-15 341 11/9/2022 MW-19 301 Page 11 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report N. Errata/Corrections to Previous ARERRs In the 2020 and 2021 Annual Radioactive Effluent Release Reports (ARERR), BFN reported Total Iodines in Table 1A - Summation of all Releases, instead of Total I-131 Releases (CR 1844572). BFN is committed to Regulatory Guide 1.21 Revision 1; this revision requires only I-131 total releases to be reported in Table 1A. The two tables below are the 2020 and 2021 Table 1A Gaseous Effluents - Summations of all Releases section B. Iodines with I-131 reported for each respective year.
2020 Table 1-A Gaseous Effluents - Summation of all Releases 1st 2nd 3rd 4th Units Total Error %
Quarter Quarter Quarter Quarter B. Iodines
- 1. Total I-131 Release Curies 2.71E-04 1.02E-04 2.58E-04 9.98E-05 7.31E-04 +/- 36%
- 2. Average Release Rate for uCi/sec 3.44E-05 1.29E-05 3.27E-05 1.25E-05 2.31E-05 Period
- 4. Percent of Tech Spec Limit1 % * * * *
- 2021 Table 1-A Gaseous Effluents - Summation of all Releases 1st 2nd 3rd 4th Units Total Error %
Quarter Quarter Quarter Quarter B. Iodines
- 1. Total I-131 Release Curies 6.56E-05 1.15E-04 2.71E-04 1.06E-03 1.51E-03 +/- 36%
- 2. Average Release Rate for uCi/sec 8.44E-06 1.46E-05 3.41E-05 1.33E-04 4.79E-05 Period
- 4. Percent of Tech Spec Limit 1 % * * * *
- 1
- Applicable Limits are expressed in terms of dose. Reference Section VI, Radiological Impact, Table 3.
Page 12 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report III. Gaseous Effluents Table 1-A Gaseous Effluents - Summation of all Releases 1st 2nd 3rd 4th Units Total Error %
Quarter Quarter Quarter Quarter A. Fission and Activation Gases
- 1. Total Release Curies 6.92E+00 2.40E+00 3.10E+00 5.90E+00 1.83E+01 +/- 45%
- 2. Average Release Rate for uCi/sec 8.90E-01 3.05E-01 3.90E-01 7.43E-01 5.81E-01 Period
- 3. Percent of Tech Spec Limit % * * * *
- B. Iodines
- 1. Total I-131 Release Curies 1.86E-03 1.48E-05 5.81E-05 3.37E-05 1.97E-03 +/- 36%
- 2. Average Release Rate for uCi/sec 2.41E-04 1.88E-06 7.30E-06 4.23E-06 6.26E-05 Period
- 3. Percent of Tech Spec Limit % * * * *
- C. Particulates
- 1. Total Release Curies 8.06E-04 1.92E-04 8.61E-05 5.87E-04 1.67E-03 +/- 35%
- 2. Average Release Rate for uCi/sec 1.04E-04 2.44E-05 1.08E-05 7.38E-05 5.30E-05 Period
- 3. Percent of Tech Spec Limit % * * * *
- D. Tritium
- 1. Total Release Curies 6.89E+01 1 5.27E+011 9.34E+01 3.24E+01 2.47E+021 +/- 21%
- 2. Average Release Rate for uCi/sec 8.87E+00 6.71E+00 1.18E+01 4.07E+00 7.84E+00 Period
- 3. Percent of Tech Spec Limit % * * * *
- E. Gross Alpha
- 1. Total Release Curies <LLD <LLD <LLD <LLD <LLD
- 2. Average Release Rate for uCi/sec Period
- 3. Percent of Tech Spec Limit % * * * *
- F. Carbon-14
- 1. Total Release Curies 1.19E+01 1.38E+01 1.38E+01 1.21E+01 5.16E+01
- 2. Percent of Tech Spec Limit % * * * *
- 1 Includes activity from abnormal releases. Dilution flow was not determined for abnormal releases.
- Applicable Limits are expressed in terms of dose. Reference Section VI, Radiological Impact, Table 3.
Page 13 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Table 1-B Gaseous Effluents - Ground Level Releases (Batch) 1 1st 2nd 3rd 4th Units Total Quarter Quarter Quarter Quarter
- 1. Fission and Activation Gases Kr-85 Ci NA NA NA NA NA Kr-85m Ci NA NA NA NA NA Kr-87 Ci NA NA NA NA NA Kr-88 Ci NA NA NA NA NA Xe-133 Ci NA NA NA NA NA Xe-135m Ci NA NA NA NA NA Xe-138 Ci NA NA NA NA NA Total For Period Ci NA NA NA NA NA
- 2. Iodines I-131 Ci NA NA NA NA NA I-133 Ci NA NA NA NA NA I-135 Ci NA NA NA NA NA Total For Period Ci NA NA NA NA NA
- 3. Particulates Mn-54 Ci NA NA NA NA NA Co-58 Ci NA NA NA NA NA Co-60 Ci NA NA NA NA NA Zn-65 Ci NA NA NA NA NA Sr-89 Ci NA NA NA NA NA Sr-90 Ci NA NA NA NA NA Cs-134 Ci NA NA NA NA NA Cs-137 Ci NA NA NA NA NA Ba-140 Ci NA NA NA NA NA La-140 Ci NA NA NA NA NA Total For Period Ci NA NA NA NA NA
- 4. Gross Alpha Gross Alpha Ci NA NA NA NA NA
There were no gaseous batch releases through the ground release points in 2022.
Page 14 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Table 1-B Gaseous Effluents - Ground Level Releases (Continuous) 1st 2nd 3rd 4th Units Total Quarter Quarter Quarter Quarter
- 1. Fission and Activation Gases Kr-85 Ci <LLD <LLD <LLD <LLD <LLD Kr-85m Ci <LLD <LLD <LLD <LLD <LLD Kr-87 Ci <LLD <LLD <LLD <LLD <LLD Kr-88 Ci <LLD <LLD <LLD <LLD <LLD Xe-133 Ci <LLD <LLD <LLD <LLD <LLD Xe-135m Ci <LLD <LLD <LLD <LLD <LLD Xe-138 Ci <LLD <LLD <LLD <LLD <LLD Total For Period Ci <LLD <LLD <LLD <LLD <LLD
- 2. Iodines I-131 Ci 6.67E-05 <LLD 5.26E-06 1.22E-06 7.32E-05 I-133 Ci 4.69E-06 <LLD <LLD <LLD 4.69E-06 I-135 Ci <LLD <LLD <LLD <LLD <LLD Total For Period Ci 7.14E-05 <LLD 5.26E-06 1.22E-06 7.79E-05
- 3. Particulates Mn-54 Ci <LLD <LLD <LLD <LLD <LLD Co-58 Ci <LLD <LLD <LLD <LLD <LLD Co-60 Ci <LLD <LLD <LLD <LLD <LLD Sr-89 Ci <LLD <LLD <LLD <LLD <LLD Sr-90 Ci <LLD <LLD <LLD <LLD <LLD Cs-134 Ci <LLD <LLD <LLD <LLD <LLD Cs-137 Ci <LLD <LLD <LLD <LLD <LLD Ba-140 Ci <LLD <LLD <LLD <LLD <LLD La-140 Ci <LLD <LLD <LLD <LLD <LLD Total For Period Ci <LLD <LLD <LLD <LLD <LLD
- 4. Gross Alpha Gross Alpha Ci <LLD <LLD <LLD <LLD <LLD
Includes activity from abnormal releases. Dilution flow was not determined for abnormal releases.
Page 15 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Table 1-C Gaseous Effluents - Elevated Releases (Batch) 1 1st 2nd 3rd 4th Units Total Quarter Quarter Quarter Quarter
- 1. Fission and Activation Gases Kr-85 Ci NA NA NA NA NA Kr-85m Ci NA NA NA NA NA Kr-87 Ci NA NA NA NA NA Kr-88 Ci NA NA NA NA NA Xe-133 Ci NA NA NA NA NA Xe-135m Ci NA NA NA NA NA Xe-138 Ci NA NA NA NA NA Total For Period Ci NA NA NA NA NA
- 2. Iodines I-131 Ci NA NA NA NA NA I-133 Ci NA NA NA NA NA I-135 Ci NA NA NA NA NA Total For Period Ci NA NA NA NA NA
- 3. Particulates Mn-54 Ci NA NA NA NA NA Co-58 Ci NA NA NA NA NA Co-60 Ci NA NA NA NA NA Zn-65 Ci NA NA NA NA NA Sr-89 Ci NA NA NA NA NA Sr-90 Ci NA NA NA NA NA Cs-134 Ci NA NA NA NA NA Cs-137 Ci NA NA NA NA NA Ba-140 Ci NA NA NA NA NA La-140 Ci NA NA NA NA NA Total For Period Ci NA NA NA NA NA
- 4. Gross Alpha Gross Alpha Ci NA NA NA NA NA
There were no gaseous batch releases through the elevated release point in 2022.
Page 16 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Table 1-C Gaseous Effluents - Elevated Releases (Continuous) 1st 2nd 3rd 4th Units Total Quarter Quarter Quarter Quarter
- 1. Fission and Activation Gases Ar-41 Ci 1.43E+00 2.40E+00 8.36E-01 3.82E+00 8.49E+00 Kr-85m Ci <LLD <LLD <LLD <LLD <LLD Kr-85 Ci <LLD <LLD <LLD <LLD <LLD Kr-87 Ci <LLD <LLD <LLD <LLD <LLD Kr-88 Ci 1.00E+00 <LLD <LLD 3.32E-01 1.34E+00 Xe-133 Ci 4.21E+00 <LLD 2.26E+00 1.75E+00 8.22E+00 Xe-135 Ci 2.69E-01 <LLD <LLD <LLD 2.69E-01 Xe-135m Ci <LLD <LLD <LLD <LLD <LLD Xe-138 Ci <LLD <LLD <LLD <LLD <LLD Total For Period Ci 6.92E+00 2.40E+00 3.10E+00 5.90E+01 1.83E+01
- 2. Iodines I-131 Ci 9.93E-04 1.26E-05 4.40E-05 2.23E-05 1.07E-03 I-133 Ci 2.02E-04 1.77E-04 1.62E-04 4.26E-05 5.83E-04 I-135 Ci <LLD <LLD <LLD <LLD <LLD Total For Period Ci 1.20E-03 1.90E-04 2.05E-04 6.50E-05 1.66E-03
- 3. Particulates Au-199 Ci 3.25E-04 1.43E-04 5.01E-05 1.98E-04 7.17E-04 Co-60 Ci <LLD <LLD <LLD <LLD <LLD Sr-89 Ci 1.94E-06 5.97E-06 1.16E-05 <LLD 1.95E-05 Sr-90 Ci <LLD <LLD <LLD <LLD <LLD Cs-137 Ci <LLD <LLD <LLD <LLD <LLD Cs-138 Ci 4.90E-05 <LLD <LLD <LLD 4.90E-05 Ba-139 Ci 1.03E-04 <LLD <LLD <LLD 1.03E-04 La-140 Ci <LLD <LLD 4.51E-06 <LLD 4.51E-06 Total For Period Ci 4.79E-04 1.49E-04 6.61E-05 1.98E-04 8.92E-04
- 4. Gross Alpha Gross Alpha Ci <LLD <LLD <LLD <LLD <LLD
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Table 1-D Gaseous Effluents - Mixed Mode Releases (Batch) 1st 2nd 3rd 4th Units Total Quarter Quarter Quarter Quarter
- 1. Fission and Activation Gases Kr-85 Ci <LLD <LLD <LLD <LLD <LLD Kr-85m Ci <LLD <LLD <LLD <LLD <LLD Kr-87 Ci <LLD <LLD <LLD <LLD <LLD Kr-88 Ci <LLD <LLD <LLD <LLD <LLD Xe-133 Ci 7.87E-04 <LLD <LLD <LLD 7.87E-04 Xe-135m Ci 2.06E-04 <LLD <LLD <LLD 2.06E-04 Xe-138 Ci <LLD <LLD <LLD <LLD <LLD Total For Period Ci 9.93E-04 <LLD <LLD <LLD 9.93E-04
- 2. Iodines I-131 Ci <LLD <LLD <LLD <LLD <LLD I-133 Ci <LLD <LLD <LLD <LLD <LLD I-135 Ci <LLD <LLD <LLD <LLD <LLD Total For Period Ci <LLD <LLD <LLD <LLD <LLD
- 3. Particulates Co-58 Ci <LLD <LLD <LLD <LLD <LLD Co-60 Ci <LLD <LLD <LLD <LLD <LLD Zn-65 Ci <LLD <LLD <LLD <LLD <LLD Sr-89 Ci <LLD <LLD <LLD <LLD <LLD Sr-90 Ci <LLD <LLD <LLD <LLD <LLD Cs-134 Ci <LLD <LLD <LLD <LLD <LLD Cs-137 Ci <LLD <LLD <LLD <LLD <LLD Ba-140 Ci <LLD <LLD <LLD <LLD <LLD La-140 Ci <LLD <LLD <LLD <LLD <LLD Total For Period Ci <LLD <LLD <LLD <LLD <LLD
- 4. Gross Alpha Gross Alpha Ci <LLD <LLD <LLD <LLD <LLD
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Table 1-D Gaseous Effluents - Mixed Mode Releases (Continuous) 1st 2nd 3rd 4th Units Total Quarter Quarter Quarter Quarter
- 1. Fission and Activation Gases Kr-85 Ci <LLD <LLD <LLD <LLD <LLD Kr-85m Ci <LLD <LLD <LLD <LLD <LLD Kr-87 Ci <LLD <LLD <LLD <LLD <LLD Kr-88 Ci <LLD <LLD <LLD <LLD <LLD Xe-133 Ci <LLD <LLD <LLD <LLD <LLD Xe-135m Ci <LLD <LLD <LLD <LLD <LLD Xe-138 Ci <LLD <LLD <LLD <LLD <LLD Total For Period Ci <LLD <LLD <LLD <LLD <LLD
- 2. Iodines I-131 Ci 8.05E-04 2.23E-06 8.84E-06 1.02E-05 8.26E-04 I-133 Ci 1.46E-06 <LLD 2.95E-05 7.24E-05 1.03E-04 I-135 Ci <LLD <LLD <LLD <LLD <LLD Total For Period Ci 8.07E-04 2.23E-06 3.83E-05 8.26E-05 9.30E-04
- 3. Particulates Au-199 Ci <LLD <LLD <LLD 2.19E-06 2.19E-06 Se-75 Ci <LLD <LLD <LLD 1.16E-06 1.16E-06 Na-24 CI <LLD <LLD <LLD 6.98E-05 6.98E-05 Cr-51 Ci 1.13E-04 1.58E-05 <LLD 2.56E-05 1.54E-04 Mn-54 Ci 4.91E-06 2.22E-06 <LLD 5.50E-06 1.26E-05 Co-58 Ci 1.75E-05 <LLD <LLD 2.20E-05 3.95E-05 Co-60 Ci 1.76E-04 2.25E-05 1.99E-05 9.98E-05 3.18E-04 As-76 Ci <LLD <LLD <LLD 1.02E-04 1.02E-04 Sr-89 Ci <LLD <LLD <LLD <LLD <LLD Sr-90 Ci <LLD <LLD <LLD <LLD <LLD Mo-99 Ci <LLD <LLD <LLD 3.05E-06 3.05E-06 Ag-110m Ci 1.60E-05 <LLD <LLD 5.75E-05 7.36E-05 Cs-137 Ci <LLD 2.03E-06 <LLD <LLD 2.03E-06 Total For Period Ci 3.27E-04 4.26E-05 1.99E-05 3.88E-04 7.78E-04
- 4. Gross Alpha Gross Alpha Ci <LLD <LLD <LLD <LLD <LLD
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report IV. Liquid Effluents Table 2-A Liquid Effluents - Summation of all Releases 1st 2nd 3rd 4th Units Total Error %
Quarter Quarter Quarter Quarter A. Fission and Activation Products
- 1. Total Release Curies 1.63E-02 4.49E-05 NA 7.15E-03 2.35E-02 +/- 9%
- 2. Average Diluted Concentration uCi/mL 6.26E-10 3.12E-12 NA 6.77E-10 4.61E-10
- 3. Percent of Tech Spec Limit % * * * *
- B. Tritium
- 1. Total Release Curies 8.55E+00 1 2.70E-011 NA 7.92E-011 9.61E+001 +/- 6%
- 2. Average Diluted Concentration uCi/mL 3.27E-07 1.87E-08 NA 7.50E-08 1.88E-07
- 3. Percent of Tech Spec Limit % * * * *
- C. Dissolved and Entrained Noble Gases
- 1. Total Release Curies 3.86E-04 <LLD NA <LLD 3.86E-04 +/- 8%
- 2. Average Diluted Concentration uCi/mL 1.48E-11 0.00E+00 NA 0.00E+00 7.56E-12
- 3. Percent of Tech Spec Limit % * * * *
- D. Gross Alpha Radioactivity
- 1. Total Release Curies <LLD <LLD NA <LLD <LLD +/- 48%
E. Volume of Liquid Waste to Discharge Canal (prior to Liters 2.90E+06 5.00E+05 0.00E+00 7.45E+05 4.14E+06 dilution)
F. Volume of Dilution Water for Liters 2.61E+10 1.44E+10 0.00E+00 1.06E+10 5.11E+10 +/- 10%
Period G. Total CCW Gigagal 2.47E+02 2.77E+02 2.80E+02 2.51E+02 1.06E+03 1
Includes activity from abnormal releases. Dilution flow was not determined for abnormal releases.
- Applicable Limits are expressed in terms of dose. Reference Section VI, Radiological Impact, Table 4.
Page 20 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Table 2-B Liquid Effluents - Batch Mode1 1st 2nd 3rd 4th Units Total Quarter Quarter Quarter Quarter
- 1. Fission and Activation Products Na-24 Ci 1.71E-05 <LLD NA <LLD 1.71E-05 Mn-54 Ci 1.88E-03 <LLD NA 3.26E-04 2.21E-03 Co-58 Ci 8.38E-04 <LLD NA <LLD 8.38E-04 Co-60 Ci 1.00E-02 <LLD NA 5.98E-03 1.60E-02 Zn-65 Ci 2.68E-03 <LLD NA 4.04E-04 3.08E-03 Sr-92 Ci 3.66E-05 <LLD NA 1.16E-05 4.83E-05 Y-92 Ci 8.53E-05 <LLD NA <LLD 8.53E-05 Nb-97 Ci 2.09E-04 <LLD NA 4.34E-05 2.52E-04 Ag-110m Ci 2.08E-04 <LLD NA 1.95E-04 4.03E-04 Cs-137 Ci 3.33E-04 4.49E-05 NA 1.82E-04 5.60E-04 Fe-55 Ci <LLD <LLD NA <LLD <LLD Sr-89 Ci <LLD <LLD NA <LLD <LLD Sr-90 Ci <LLD <LLD NA <LLD <LLD Total For Period Ci 1.63E-02 4.49E-05 NA 7.15E-03 2.35E-02
- 2. Dissolved and Entrained Gases Xe-133 Ci 2.38E-04 <LLD NA <LLD 2.38E-04 Xe-135 Ci 1.47E-04 <LLD NA <LLD 1.47E-04 Total For Period Ci 3.86E-04 <LLD NA <LLD 3.86E-04 Table 2-B Liquid Effluents - Continuous Mode 2 1st 2nd 3rd 4th Units Total Quarter Quarter Quarter Quarter
- 1. Fission and Activation Products Co-58 Ci NA NA NA NA NA Co-60 Ci NA NA NA NA NA Total For Period Ci NA NA NA NA NA
- 2. Dissolved and Entrained Gases Xe-133 Ci NA NA NA NA NA Xe-135 Ci NA NA NA NA NA Total For Period Ci NA NA NA NA NA 1
There were no batch releases for 3rd quarter 2022.
2 There were no liquid releases through the continuous mode in 2022.
Page 21 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report V. Solid Waste Storage and Shipment A. Solid Waste Shipped Off-site for Burial or Disposal (Not Irradiated Fuel)
- 1. Type of Waste Units Jan-Jun Jul-Dec % Error
- a. Spent resins, filters, filter sludge m3 1.14E+02 1.34E+02 +/-25.0 evaporator bottoms, etc. Ci 1.20E+02 3.89E+02 +/-25.0
- b. Dry compressible waste, contaminated m3 1.96E+03 1.40E+03 +/-25.0 equipment, etc. Ci 3.54E+00 1.61E+00 +/-25.0
- c. Irradiated components, control rod m3 4.98E-01 0.00E+00 +/-25.0 blades & LPRMs with fission chambers Ci 2.15E+04 0.00E+00 +/-25.0
- d. Other - Combined Packages m3 0.00E+00 0.00E+00 +/-25.0 Ci 0.00E+00 0.00E+00 +/-25.0 Page 22 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report
- 2. Estimate of major nuclide composition (by type of waste)
- a. Spent resins, filters, filter sludge evaporator bottoms, etc.
Nuclide Percentage Curies
- 1. H-3 1.15E-01 5.84E-01
- 2. C-14 6.16E-02 3.13E-01
- 3. Mn-54 7.79E+00 3.96E+01
- 4. Fe-55 1.73E+01 8.82E+01
- 5. Co-58 1.36E+00 6.93E+00
- 6. Co-60 5.03E+01 2.56E+02
- 7. Ni-63 8.60E-01 4.37E+00
- 8. Zn-65 8.65E+00 4.40E+01
- 9. Sr-89 3.82E-03 1.94E-02
- 10. Sr-90 6.85E-03 3.48E-02
- 11. Tc-99 8.30E-03 4.22E-02
- 12. Ag-110m 1.01E+01 5.16E+01
- 13. Sb-124 2.64E-02 1.34E-01
- 14. Cs-134 2.42E-01 1.23E+00
- 15. Cs-137 3.04E+00 1.55E+01 Page 23 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report
- b. Dry compressible waste, contaminated equipment, etc.
Nuclide Percentage Curies
- 1. H-3 9.80E-02 5.05E-03
- 2. F-18 3.38E-06 1.74E-07
- 3. Na-24 3.08E-01 1.59E-02
- 4. Cr-51 1.47E+00 7.57E-02
- 5. Mn-54 5.55E+00 2.86E-01
- 6. Fe-55 6.99E+00 3.60E-01
- 7. Fe-59 4.71E-01 2.43E-02 8 Co-58 2.26E+01 1.17E+00
- 9. Co-60 4.55E+01 2.35E+00
- 10. Ni-63 1.40E+00 7.22E-02
- 11. Zn-65 2.93E+00 1.51E-01
- 12. Sr-89 1.34E-03 6.89E-05
- 13. Sr-90 4.44E-04 2.29E-05
- 14. Zr-97 7.64E-02 3.94E-03
- 15. Nb-95 7.53E-02 3.88E-03
- 16. Nb-97 2.54E-04 1.31E-05
- 17. Tc-99 7.31E-01 3.77E-02
- 18. Ag-110m 3.17E+00 1.64E-01
- 19. Sb-124 3.61E-02 1.86E-03
- 20. Sb-125 1.08E-02 5.58E-04
- 21. Cs-134 3.27E+00 1.69E-01
- 22. Cs-137 5.26E+00 2.71E-01
- 23. La-140 2.51E+00 1.29E-01 Page 24 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report
- c. Irradiated components, control rod blades & LPRMs with fission chambers Nuclide Percentage Curies
- 1. H-3 1.51E-02 3.24E+00
- 2. C-14 8.93E-03 1.92E+00
- 3. Cr-51 2.71E-05 5.83E-03
- 4. Mn-54 1.79E+00 3.85E+02
- 5. Fe-55 7.21E+01 1.55E+04
- 6. Fe-59 2.12E-04 4.57E-02
- 7. Co-58 2.09E-02 4.49E+00
- 8. Co-60 1.97E+01 4.23E+03
- 9. Ni-59 3.37E-02 7.24E+00
- 10. Ni-63 6.37E+00 1.37E+03
- 11. Zn-65 3.51E-02 7.54E+00
- 12. Nb-94 1.92E-04 4.14E-02
- 13. Nb-95 7.76E-05 1.67E-02
- 14. Tc-99 3.60E-05 7.75E-03
- 15. Ag-100m 9.16E-05 1.97E-02
- 16. Sb-124 5.44E-05 1.17E-02
- 17. Cs-137 2.92E-05 6.28E-03
- d. Other -Combined Packages Nuclide Percentage Curies
- 1. 0 0 0 Page 25 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report
- 3. Sold Waste Disposition Number of Shipments Mode of Transportation Destination TOXCO, Inc.
2 ESS(TVA)
Materials Management Center Energy Solutions LLC.(Clive) 6 Hittman Transport Services Clive Disposal Site - Containerized Waste Facility Energy Solutions Memphis 5 Hittman Transport Services 1790 Dock Street Energy Solutions Services Inc.
10 Hittman Transport Services 1560 Bear Creek Road Waste Control Specialist, LLC 2 Hittman Transport Services CWF Waste Control Specialist, LLC 20 Interstate Ventures, Inc.
TSDF Waste Control Specialist, LLC 27 Interstate Ventures, Inc CWF Unitech Service Group, Inc.
78 Specialty Transport, Inc.
Oak Ridge Services Center B. Irradiated Fuel Shipments (Disposition)
Number of Shipments Mode of Transportation Destination Waste Control Specialist, LLC 3 Hittman Transport Services CWF Page 26 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Radiological Impact VI. Radiological Impact to Man A. Introduction Potential doses to the "maximum exposed individual" and the population around Browns Ferry Nuclear Plant (BFN) are calculated for each quarter as required in Section 5.2 of the Offsite Dose Calculation Manual (ODCM). The methodology used to estimate dose for determining plant releases for the reporting period is specified in Sections 6 and 7 of the ODCM. Dispersion of radioactive effluents in the environment is estimated using meteorological data and river flow measured during the period. In this report, the doses resulting from releases are described and compared to limits established for BFN.
B. Dose Limits The ODCM specifies limits for the release of radioactive effluents, as well as limits for doses to the general public from the release of radioactive effluents. These limits are set well below the Technical Specification limits which govern the concentrations of radioactivity and doses permissible in unrestricted areas. This ensures that radioactive effluent releases are As Low As Reasonably Achievable.
The air dose limits in areas at and beyond the Site Boundary due to noble gases released in gaseous effluents per unit are:
- 5 mrad per quarter and 10 mrad per year for gamma radiation.
and
- 10 mrad per quarter and 20 mrad per year for beta radiation.
The dose limits to a member of the public in an unrestricted area from radioiodines, radioactive materials in particulate form, and radionuclides other than noble gases with half lives > 8 days released in gaseous effluents for each unit are:
- 7.5 mrem per quarter and 15 mrem per year to any organ.
The dose or dose commitment to a member of the public from radioactive material in liquid effluents released to unrestricted areas are:
- 1.5 mrem per quarter and 3 mrem per year to the total body, and
- 5 mrem per quarter and 10 mrem per year to any organ.
The limit for the total effective dose equivalent to an individual member of the public inside the site boundary is:
- 100 mrem per year.
Page 27 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Radiological Impact The Environmental Protection Agency limits for total dose to any member of the public in the vicinity of a nuclear power plant, established in the Environmental Dose Standard of 40 CFR 190, are:
- 25 mrem per year to the whole body, 75 mrem per year to the thyroid, and
- 25 mrem per year to any other organ.
C. Dose Calculations Estimated doses to members of the public are determined using computer models (the Gaseous Effluent Licensing Code, and the Quarterly Water Dose Assessment Code (QWATA)).
These models are based on guidance provided by the Nuclear Regulatory Commission (NRC) for determining the potential dose to individuals and populations living in the vicinity of the plant. The area around the plant is analyzed to determine the pathways through which the public may receive a dose. The doses calculated are a representation of the dose to a "maximum exposed individual." Some of the factors used in these calculations (such as ingestion rates) are maximum values to ensure conservative reporting of data. The values chosen will tend to overestimate the dose. The expected dose to actual individuals is lower.
The calculated doses are presented in Tables 3, 4, and 5.
D. Doses from Airborne Effluents For airborne effluents, members of the public can be exposed to radiation from several sources: direct radiation from the radioactivity in the air, direct radiation from radioactivity deposited on the ground, inhalation of airborne radioactivity, ingestion of vegetation which contains radioactivity deposited from the atmosphere, and ingestion of milk and beef which contains radioactivity deposited from the atmosphere onto vegetation and subsequently consumed by animals.
Releases from the stack are considered to be elevated releases. The JFDs for elevated releases are based on wind directions and wind speeds measured at 90.29 meters and the vertical temperature difference between 10.03 and 89.59 meters, and are given for each quarter in the 2022 Meteorological Data Tables.
Meteorological variables at BFN are measured continuously. Measurements collected include wind speed and wind direction at heights of 10.5, 45.74, and 90.29 meters above the ground, and temperature at heights of 10.03, 45.30, and 89.59 meters above the ground.
Quarterly JFDs are calculated for each release point using the appropriate levels of meteorological data. A quarterly JFD gives the percentage of the time that the wind is blowing out of a particular upwind compass sector in a particular range of wind speeds for a given stability class A through G. The wind speeds are divided into nine wind speed ranges.
Calms are distributed by direction in proportion to the distribution of noncalm wind directions less than 1.6 m/s (3.5 mph). Stability classes are determined from the vertical temperature difference between two measurement levels.
Page 28 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Radiological Impact The generally open terrain around BFN does not cause any significant effects on the transport and dispersion of gaseous effluents from the plant. Within 30 kilometers of BFN, the terrain is mostly gently rolling hills (30-60 meters). Between 30 and 80 kilometers, the hills become larger to the north and south and mountainous to the east and northeast. The Tennessee River/Wheeler Lake may have a minor effect on transport and dispersion in the immediate vicinity of BFN during periods of winds with a southerly component, overcast skies, and relatively high wind speeds. Also, the lower layer (10-45 meters) stability class tends to be more stable. However, during this infrequent condition, dose estimates will be conservative.
Dose calculated for maximum external air dose (gamma-air and beta-air) are made for points at and beyond the unrestricted area boundary as described in the BFN ODCM. The highest of these doses is then selected.
External doses to the skin and total body, due to submersion in a cloud of noble gases, are calculated for the nearest residence in each sector. The residence with the highest dose is then selected from all sectors.
Dose to an organ due to releases of airborne effluents are estimated for the inhalation, ground contamination, and ingestion pathways. The ingestion pathway is further divided into three possible contributing pathways: ingestion of cow/goat milk, ingestion of beef, and ingestion of vegetables. Doses from applicable pathways are calculated for each receptor location identified in the most recent land use survey. To determine the maximum organ dose, the doses from the pathways are summed for each receptor. However, for the ingestion dose, only those pathways that exist for each receptor are considered in the sum, e.g., milk ingestion doses are included only for locations where milk was consumed without commercial preparation and vegetable ingestion is included only for those locations where a garden was identified. To conservatively account for beef ingestion, a beef ingestion dose equal to that for the highest unrestricted area boundary location is added to each identified receptor. For ground contamination, the dose added to the organ dose being calculated is the total body dose calculated for that location, i.e., it is assumed that the dose to an individual organ is equal to the total body dose.
The maximum organ dose, thyroid dose, and total body dose from airborne effluents are presented in Table 3.
E. Doses from Liquid Effluents For liquid effluents, the public can be exposed to radiation from three sources: the ingestion of water from the Tennessee River, the ingestion of fish caught in the Tennessee River, and direct exposure from radioactive material deposited on the river shoreline sediment (recreation). The concentration of radionuclides in the Tennessee River is calculated by a computer model which uses measured hydraulic data downstream of BFN.
Parameters used to determine the doses are based on guidance given by the NRC for maximum ingestion rates, exposure times, etc.
Page 29 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Radiological Impact Wherever possible, parameters used in the dose calculation are site specific. The models that are used to estimate doses, as well as the parameters input to the models, are described in detail in the BFN ODCM.
Radionuclide concentrations in the Tennessee River are calculated assuming that releases in liquid effluents are continuous. When necessary, liquid releases from BFN, located at Tennessee River Mile 294, are made through diffusers which extend into the Tennessee River. It is assumed that releases to the river through these diffusers will initially be entrained in one-fifth of the water which flows past the plant. The QWATA code makes the assumption that this mixing condition holds true until the water is completely mixed at the first downstream dam (Wheeler Dam), at Tennessee River Mile 283.
Doses are calculated for locations within a 50 mile radius downstream of the plant site.
The maximum potential recreation dose is calculated for a location immediately downstream from the plants release point. The maximum exposed individual dose from ingestion of fish is assumed to be that calculated for the consumption of fish caught anywhere between the plant and the first downstream dam. The maximum exposed individual dose from drinking water is assumed to be that calculated at the nearest downstream public water supply [West Morgan - East Lawrence (WMEL)]. This could be interpreted as indicating that the maximum exposed individual, as assumed for liquid releases from BFN, is an individual who obtains all drinking water at WMEL, consumes fish caught from the Tennessee River between BFN and Wheeler Dam, and spends 500 hours0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> per year on the shoreline just downstream of the plants release point. Doses calculated for the maximum exposed individual due to liquid effluents for each quarter in the period are presented in Table 4 along with the average river flows past the plant site for the periods.
F. Population Doses Population doses due to airborne effluents are calculated for people living within a 50-mile radius of the plant site. Doses from external pathways and inhalation are based on the 50-mile human population distribution. Ingestion population doses are calculated assuming that each individual consumed milk, vegetables, and meat produced within the sector in which the individual resides.
Population doses due to liquid effluents are calculated for the entire downstream Tennessee River population. Water ingestion population doses are calculated using actual population figures for downstream public water supplies. Fish ingestion population doses are calculated assuming that all sport fish caught in the Tennessee River are consumed by the Tennessee River population. Recreation population doses are calculated using historical recreational data on the number of shoreline visits at downstream locations.
Population doses calculated for airborne and liquid effluents are presented in Tables 3 and 4.
Page 30 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Radiological Impact G. Offsite Direct Radiation Dose External gamma radiation levels were measured by environmental dosimeters deployed around BFN as part of the 2022 Radiological Environmental Monitoring Program (REMP). The 2022 environmental dosimeters were evaluated in accordance with the guidance provided in ANSI N13.37-2014. The process of this evaluation is summarized: 1) The average field dosimeter results is determined for each location and normalized to a standard quarter of 91 days, 2) The field results is adjusted by the transit and shield (storage) dose to determine the net dose at each location; this is performed at each location for each quarter, and the four quarters are summed to determine the annual net dose, 3) The quarterly and annual historical average net dose was determined for each monitoring location, based on data from 2017-2021, 4) The standard deviation of each historical net dose was calculated, to determine the 90th percentile standard deviation for both the quarterly and annual results,
- 5) the 2022 quarterly and annual net dose are compared to the historical averages (plus 3 times the 90th percentile standard deviation, also known as the minimum differential dose) to determine if any facility related dose was identified at any location during any quarter or the year.
The monitoring locations are grouped according to the distance from the plant. The onsite group consists of dosimeters within 2 miles of the plant. The offsite group consists of all locations greater than 2 miles from the plant. This difference in onsite and offsite averages is consistent with levels measured for preoperational and construction phases at BFN where the average radiation levels onsite were generally 2-6 mrem/quarter higher than the levels offsite. This may be attributed to natural variations in environmental radiation levels, earth moving activities onsite, the mass of concrete employed in the construction of the plant, or other undermined influences. In order to implement the methodology of ANSI N13.37-2014, the dose received by dosimeters in shielded storage that are used as unexposed controls was determined. This in turn was used to account for extraneous dose that should be removed from the gross measurements as measured by field dosimeters.
The result of the evaluation of environmental dosimeters is that there was no facility related dose measured in the environment around Browns Ferry. There were no quarterly or annual dosimeters that exceed the historical baseline plus the calculated minimum differential dose.
H. Dose to a Member of the Public Inside the Site Boundary Pursuant to ODCM Section 7.7.5, a review was performed to determine the highest dose to a hypothetical member of the public in the site boundary. The dose to a member of the public consists of the sum of dose commitments from effluent releases as well as any direct radiation dose. The gaseous effluent dose commitment is negligible compared to the direct radiation dose.
The direct radiation dose was determined from area environmental dosimeters located on-site. The critical location was determined to be an Optically Stimulated Luminescence (OSL) dosimeter near the Livewell Center (SE-1). The Annual baseline is 79 mrem/yr with the 2022 Annual dose of 77.8. The direct radiation dose at the Livewell Center, accounting for background and occupancy, was determined to be non-detectable as this location did not exceed the historical baseline plus the calculated minimum differential dose.
Page 31 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Radiological Impact I. Total Dose To determine compliance with 40 CFR 190, annual total dose contributions to the maximum exposed individual from BFN radioactive effluents and all other nearby uranium fuel cycle sources are considered.
The annual dose to any organ other than the thyroid for the maximum exposed individual is conservatively calculated by summing the following doses: the total body air submersion dose for each quarter, the critical organ dose (for any organ other than the thyroid) from airborne effluents for each quarter from ground contamination, inhalation and ingestion, the total body dose from liquid effluents for each quarter, the maximum organ dose (for any organ other than the thyroid) from liquid effluents for each quarter, and any identifiable increase in direct radiation dose levels as measured by the REMP. This dose is compared to the 40 CFR 190 limit for total body or any organ dose (other than the thyroid) to determine compliance.
The annual thyroid dose to the maximum exposed individual is conservatively estimated by summing the following doses: the total body air submersion dose for each quarter, the thyroid dose from airborne effluents for each quarter, the total body dose from liquid effluents for each quarter, the thyroid dose from liquid effluents for each quarter, and any identifiable increase in direct radiation dose levels as measured by the REMP. This dose is compared to the 40 CFR 190 limit for thyroid dose to determine compliance.
Total dose from the fuel cycle is presented in Table 5.
Page 32 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Radiological Impact J. Tables Table 3-A Doses from Airborne Effluents - 1st Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location Beta Air 3.77E-06 mrad 10 mrad < 1% S 5900 meters Gamma Air 8.75E-06 mrad 5 mrad < 1% S 5900 meters NG Skin 4.94E-04 mrad NA < 1% NNW 1650 meters NG Total Body 4.20E-04 mrad NA < 1% NNW 1650 meters Organ Doses (Iodine, Tritium, Particulates with >8-Day half-life)
Child / Bone 1.97E-02 mrem 7.5 mrem < 1% S 5700 meters Child / Thyroid 6.78E-03 mrem 7.5 mrem < 1% E 1530 meters Child / Total Body 4.94E-03 mrem 7.5 mrem < 1% S 5700 meters Population Doses Total Body Dose 1.71E-01 man-rem Maximum Organ Dose (Organ) 7.51E-01 man-rem (Bone)
Table 3-B Doses from Airborne Effluents - 2nd Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location Beta Air 3.67E-06 mrad 10 mrad < 1% NNW 5000 meters Gamma Air 1.04E-05 mrad 5 mrad < 1% NNW 5000 meters NG Skin 9.54E-05 mrad NA NA NNW 1650 meters NG Total Body 8.00E-05 mrad NA NA NNW 1650 meters Organ Doses (Iodine, Tritium, Particulates with >8-Day half-life)
Child / Bone 3.85E-02 mrem 7.5 mrem < 1% NNW 4350 meters Child / Thyroid 9.93E-03 mrem 7.5 mrem < 1% NNW 4350 meters Child / Total Body 9.93E-03 mrem 7.5 mrem < 1% NNW 1650 meters Population Doses Total Body Dose 2.05E-01 man-rem Maximum Organ Dose (Organ) 9.15E-01 man-rem (Bone)
Page 33 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Radiological Impact Table 3-C Doses from Airborne Effluents - 3rd Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location Beta Air 4.61E-06 mrad 10 mrad < 1% NE 4800 meters Gamma Air 7.13E-06 mrad 5 mrad < 1% NE 4800 meters NG Skin 5.42E-05 mrad NA NA NE 2020 meters NG Total Body 4.45E-05 mrad NA NA NE 2020 meters Organ Doses (Iodine, Tritium, Particulates with >8-Day half-life)
Child / Bone 7.14E-02 mrem 7.5 mrem < 1% NE 4540 meters Child / Thyroid 1.75E-02 mrem 7.5 mrem < 1% NE 4290 meters Child / Total Body 1.74E-02 mrem 7.5 mrem < 1% NE 4290 meters Population Doses Total Body Dose 2.55E-01 man-rem Maximum Organ Dose (Organ) 1.11E+00 man-rem (Bone)
Table 3-D Doses from Airborne Effluents - 4th Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location Beta Air 4.42E-06 mrad 10 mrad < 1% E 4800 meters Gamma Air 1.17E-05 mrad 5 mrad < 1% E 4800 meters NG Skin 3.19E-04 mrad NA NA E 1410 meters NG Total Body 2.70E-04 mrad NA NA E 1410 meters Organ Doses (Iodine, Tritium, Particulates with >8-Day half-life)
Child / Bone 1.94E-02 mrem 7.5 mrem < 1% E 4240 meters Child / Thyroid 5.93E-03 mrem 7.5 mrem < 1% E 1530 meters Child / Total Body 5.95E-03 mrem 7.5 mrem < 1% E 1530 meters Population Doses Total Body Dose 1.63E-01 man-rem Maximum Organ Dose (Organ) 7.26E-01 man-rem (Bone)
Page 34 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Radiological Impact Table 4-A Doses from Liquid Effluents - 1st Quarter Individual Doses Age Group Organ Dose Quarterly Limit Percent of Limit Adult Liver 3.61E-04 mrem 5 mrem < 1%
Child Thyroid 2.26E-04 mrem 5 mrem < 1%
Adult Total Body 2.97E-04 mrem 1.5 mrem < 1%
Average River Flow past BFN: 89,700 CFS Population Doses Total Body Dose 2.00E-02 man-rem Maximum Organ Dose (Organ) 2.00E-02 man-rem (Liver)
Table 4-B Doses from Liquid Effluents - 2nd Quarter Individual Doses Age Group Organ Dose Quarterly Limit Percent of Limit Child Bone 3.57E-05 mrem 5 mrem < 1%
Child Thyroid 5.65E-06 mrem 5 mrem < 1%
Adult Total Body 2.38E-05 mrem 1.5 mrem < 1%
Average River Flow past BFN: 24,890 CFS Population Doses Total Body Dose 3.20E-04 man-rem Maximum Organ Dose (Organ) 4.30E-04 man-rem (Liver)
Page 35 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Radiological Impact Table 4-C Doses from Liquid Effluents - 3rd Quarter Individual Doses Age Group Organ Dose Quarterly Limit Percent of Limit Adult Liver 0.00E+00 mrem 5 mrem < 1%
Child Thyroid 0.00E+00 mrem 5 mrem < 1%
Adult Total Body 0.00E+00 mrem 1.5 mrem < 1%
Average River Flow past BFN: 28,673 CFS Population Doses Total Body Dose 0.00E+00 man-rem Maximum Organ Dose (Organ) 0.00E+00 man-rem Table 4-D Doses from Liquid Effluents - 4th Quarter Individual Doses Age Group Organ Dose Quarterly Limit Percent of Limit Adult Liver 3.47E-04 mrem 5 mrem < 1%
Infant Thyroid 2.48E-04 mrem 5 mrem < 1%
Adult Total Body 3.09E-04 mrem 1.5 mrem < 1%
Average River Flow past BFN: 40,861 CFS Population Doses Total Body Dose 2.50E-02 man-rem Maximum Organ Dose (Organ) 2.50E-02 man-rem (Liver)
Page 36 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Radiological Impact Table 4-E Total Dose from I-131 Water Ingestion Individual Doses 1st 2nd 3rd 4th Total Quarter Quarter Quarter Quarter I-131 (Ci) <LLD <LLD <LLD <LLD <LLD Thyroid (mrem) NA NA NA NA NA Population /
NA NA NA NA NA Thyroid (mrem)
The REMP requirements as specified in Table 3.12-1 from NUREG 1302, Offsite Dose Calculation Manual Guidance: Standard Radiological Effluent Controls for Boiling Water Reactors, dated April 1991, requires an I-131 specific analysis for drinking water pathway samples if the annual dose from I-131 is greater than 1 mrem.
In order to evaluate the need for implementation of this additional analysis, the drinking water pathway dose from I-131 to the maximum organ and age group is calculated. Based on Table 4-E, the performance of the I-131 specific analysis is not required for BFN REMP drinking water samples in 2022, as I-131 was not identified in any liquid effluent from the plant.
Page 37 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Radiological Impact Table 5 Total Dose from Fuel Cycle First Second Third Fourth Dose Quarter Quarter Quarter Quarter Total Body or any Organ (except thyroid)
Total body air 4.20E-04 8.00E-05 6.02E-05 2.70E-04 (submersion)
Critical organ dose 1.97E-02 3.85E-02 7.14E-02 1.94E-02 (airborne)
Total body 2.97E-04 2.38E-05 0.00E+00 3.09E-04 dose (liquid)
Maximum organ dose 3.61E-04 3.57E-05 0.00E+00 3.47E-04 (liquid)
Direct Radiation 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Dose Total 2.08E-02 3.86E-02 7.14E-02 2.03E-02 Cumulative Total Dose (mrem) 1.51E-01 Annual Dose Limit (mrem) 25 Percent of Limit < 1%
Thyroid Total body air 4.20E-04 8.00E-05 6.02E-05 2.70E-04 (submersion)
Thyroid dose 6.78E-03 9.93E-03 1.75E-02 5.93E-03 (airborne)
Total body dose 2.97E-04 2.38E-05 0.00E+00 3.09E-04 (liquid)
Thyroid dose 2.26E-04 5.65E-06 0.00E+00 2.48E-04 (liquid)
Total 7.72E-03 1.00E-02 1.76E-02 6.76E-03 Cumulative Total Dose (mrem) 4.21E-02 Annual Dose Limit (mrem) 75 Percent of Limit < 1%
Page 38 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data VII. Meteorological Data Table 6-A Ground Level Releases - 1st Quarter JFD Joint Frequency Distribution In Percent Page 39 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.101 0.202 0.000 0.000 0.000 0.303 NNE 0.000 0.000 0.000 0.000 0.000 0.202 0.000 0.000 0.000 0.202 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.050 SE 0.000 0.000 0.000 0.151 0.202 0.151 0.050 0.000 0.000 0.555 SSE 0.000 0.000 0.000 0.101 0.101 0.303 0.000 0.000 0.000 0.505 S 0.000 0.000 0.000 0.050 0.303 0.050 0.000 0.000 0.000 0.404 SSW 0.000 0.000 0.000 0.000 0.252 0.000 0.000 0.000 0.000 0.252 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.050 WSW 0.000 0.000 0.000 0.050 0.101 0.000 0.000 0.000 0.000 0.151 W 0.000 0.000 0.000 0.101 0.050 0.000 0.050 0.000 0.000 0.202 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.101 0.000 0.000 0.101 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.101 0.000 0.000 0.101 NNW 0.000 0.000 0.000 0.000 0.000 0.202 0.050 0.000 0.000 0.252 SUBTOTAL 0.000 0.000 0.000 0.454 1.110 1.160 0.404 0.000 0.000 3.128 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 1995 TOTAL HOURS OF STABILITY CLASS A 62 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A 62 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 1982 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2022/04/07 MEAN WIND SPEED = 8.37 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 40 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.202 1.009 0.000 0.000 0.000 1.211 NNE 0.000 0.000 0.000 0.000 0.151 0.303 0.000 0.000 0.000 0.454 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.353 0.151 0.101 0.000 0.000 0.000 0.605 SSE 0.000 0.000 0.000 0.101 0.050 0.050 0.000 0.000 0.000 0.202 S 0.000 0.000 0.000 0.050 0.101 0.000 0.000 0.000 0.000 0.151 SSW 0.000 0.000 0.000 0.050 0.050 0.000 0.000 0.000 0.000 0.101 SW 0.000 0.000 0.050 0.050 0.000 0.000 0.000 0.000 0.000 0.101 WSW 0.000 0.000 0.000 0.000 0.151 0.050 0.101 0.000 0.000 0.303 W 0.000 0.000 0.000 0.000 0.101 0.252 0.050 0.000 0.000 0.404 WNW 0.000 0.000 0.050 0.101 0.151 0.151 0.050 0.101 0.000 0.605 NW 0.000 0.000 0.000 0.050 0.101 0.050 0.252 0.000 0.000 0.454 NNW 0.000 0.000 0.000 0.000 0.050 0.202 0.101 0.000 0.000 0.353 SUBTOTAL 0.000 0.000 0.101 0.757 1.261 2.170 0.555 0.101 0.000 4.945 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 1995 TOTAL HOURS OF STABILITY CLASS B 98 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B 98 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 1982 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2022/04/07 MEAN WIND SPEED = 8.30 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 41 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.202 0.252 0.404 0.101 0.000 0.000 0.959 NNE 0.000 0.000 0.050 0.101 0.303 0.151 0.000 0.000 0.000 0.605 NE 0.000 0.000 0.000 0.000 0.151 0.050 0.000 0.000 0.000 0.202 ENE 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.000 0.050 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.050 SE 0.000 0.000 0.000 0.151 0.303 0.252 0.000 0.000 0.000 0.706 SSE 0.000 0.000 0.050 0.050 0.000 0.000 0.000 0.000 0.000 0.101 S 0.000 0.000 0.101 0.050 0.000 0.101 0.000 0.000 0.000 0.252 SSW 0.000 0.000 0.000 0.151 0.000 0.000 0.000 0.000 0.000 0.151 SW 0.000 0.000 0.000 0.000 0.050 0.000 0.151 0.000 0.000 0.202 WSW 0.000 0.000 0.050 0.151 0.101 0.202 0.050 0.000 0.000 0.555 W 0.000 0.000 0.000 0.151 0.303 0.303 0.202 0.000 0.000 0.959 WNW 0.000 0.000 0.000 0.202 0.050 0.353 0.303 0.050 0.000 0.959 NW 0.000 0.000 0.050 0.151 0.151 0.151 0.050 0.000 0.000 0.555 NNW 0.000 0.000 0.000 0.101 0.101 0.505 0.000 0.000 0.000 0.706 SUBTOTAL 0.000 0.000 0.303 1.514 1.816 2.472 0.858 0.050 0.000 7.013 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 1995 TOTAL HOURS OF STABILITY CLASS C 139 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 139 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 1982 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2022/04/07 MEAN WIND SPEED = 7.83 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 42 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.151 0.404 0.706 1.665 0.050 0.000 0.000 2.977 NNE 0.000 0.000 0.202 0.353 0.555 1.060 0.000 0.000 0.000 2.170 NE 0.000 0.000 0.101 0.555 0.454 0.505 0.000 0.000 0.000 1.615 ENE 0.000 0.000 0.050 0.151 0.303 0.252 0.000 0.000 0.000 0.757 E 0.000 0.000 0.252 0.303 0.404 0.202 0.000 0.000 0.000 1.160 ESE 0.000 0.000 0.101 0.505 0.353 0.252 0.000 0.000 0.000 1.211 SE 0.000 0.000 0.252 0.555 0.202 0.555 0.000 0.000 0.000 1.564 SSE 0.000 0.000 0.202 0.353 0.252 0.706 0.000 0.000 0.000 1.514 S 0.000 0.000 0.252 0.101 0.353 0.757 0.101 0.000 0.000 1.564 SSW 0.000 0.050 0.202 0.101 0.303 0.303 0.050 0.000 0.000 1.009 SW 0.000 0.000 0.151 0.303 0.101 0.605 0.050 0.000 0.000 1.211 WSW 0.000 0.000 0.050 0.303 0.454 0.656 0.000 0.000 0.000 1.463 W 0.000 0.000 0.202 0.202 0.505 1.463 0.101 0.000 0.000 2.472 WNW 0.000 0.000 0.101 0.555 0.505 1.060 0.908 0.151 0.000 3.280 NW 0.000 0.000 0.000 0.151 0.454 2.119 1.615 0.303 0.000 4.642 NNW 0.000 0.000 0.101 0.202 0.505 2.926 1.110 0.101 0.000 4.945 SUBTOTAL 0.000 0.050 2.371 5.096 6.408 15.086 3.986 0.555 0.000 33.552 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 1995 TOTAL HOURS OF STABILITY CLASS D 671 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D 665 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 1982 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2022/04/07 MEAN WIND SPEED = 8.44 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 43 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.101 0.404 0.252 0.404 0.757 0.000 0.000 0.000 1.917 NNE 0.000 0.000 0.303 0.858 0.151 0.101 0.000 0.000 0.000 1.413 NE 0.000 0.101 0.555 0.605 0.252 0.404 0.000 0.000 0.000 1.917 ENE 0.000 0.050 0.555 0.454 0.252 0.050 0.000 0.000 0.000 1.362 E 0.000 0.050 0.151 0.303 0.101 0.101 0.000 0.000 0.000 0.706 ESE 0.000 0.000 0.252 0.404 0.202 0.050 0.000 0.000 0.000 0.908 SE 0.000 0.050 0.353 0.454 1.060 1.261 0.050 0.000 0.000 3.229 SSE 0.000 0.101 0.505 0.404 0.656 2.674 0.202 0.000 0.000 4.541 S 0.000 0.000 0.252 0.404 0.706 1.413 1.968 0.555 0.000 5.298 SSW 0.000 0.000 0.454 0.252 0.252 0.404 0.555 0.101 0.000 2.018 SW 0.000 0.101 0.202 0.404 0.101 0.151 0.000 0.000 0.000 0.959 WSW 0.000 0.101 0.252 0.101 0.050 0.050 0.000 0.000 0.000 0.555 W 0.000 0.000 0.252 0.454 0.202 0.000 0.000 0.000 0.000 0.908 WNW 0.000 0.000 0.252 0.505 0.101 0.151 0.101 0.000 0.000 1.110 NW 0.000 0.050 0.505 0.555 0.404 0.303 0.000 0.000 0.000 1.816 NNW 0.000 0.000 0.555 0.505 0.555 0.353 0.000 0.000 0.000 1.968 SUBTOTAL 0.000 0.706 5.802 6.912 5.449 8.224 2.876 0.656 0.000 30.626 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 1995 TOTAL HOURS OF STABILITY CLASS E 614 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E 607 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 1982 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2022/04/07 MEAN WIND SPEED = 7.08 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 44 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.353 0.404 0.000 0.000 0.000 0.000 0.000 0.757 NNE 0.000 0.151 0.353 0.202 0.050 0.000 0.000 0.000 0.000 0.757 NE 0.000 0.050 0.252 0.000 0.000 0.000 0.000 0.000 0.000 0.303 ENE 0.000 0.050 0.252 0.202 0.000 0.000 0.000 0.000 0.000 0.505 E 0.000 0.000 1.009 0.605 0.000 0.000 0.000 0.000 0.000 1.615 ESE 0.000 0.101 0.555 0.404 0.101 0.000 0.000 0.000 0.000 1.160 SE 0.000 0.000 0.706 0.303 0.505 0.252 0.000 0.000 0.000 1.766 SSE 0.000 0.000 0.454 0.202 0.454 1.413 0.151 0.050 0.000 2.725 S 0.000 0.101 0.202 0.101 0.303 0.858 0.252 0.050 0.000 1.867 SSW 0.000 0.050 0.202 0.050 0.050 0.000 0.000 0.000 0.000 0.353 SW 0.000 0.000 0.101 0.050 0.151 0.050 0.000 0.000 0.000 0.353 WSW 0.000 0.000 0.151 0.000 0.000 0.000 0.000 0.000 0.000 0.151 W 0.000 0.000 0.151 0.050 0.000 0.000 0.000 0.000 0.000 0.202 WNW 0.000 0.000 0.151 0.050 0.000 0.000 0.000 0.000 0.000 0.202 NW 0.000 0.000 0.454 0.151 0.000 0.000 0.000 0.000 0.000 0.605 NNW 0.000 0.000 0.454 0.656 0.050 0.000 0.000 0.000 0.000 1.160 SUBTOTAL 0.000 0.505 5.802 3.431 1.665 2.573 0.404 0.101 0.000 14.480 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 1995 TOTAL HOURS OF STABILITY CLASS F 287 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F 287 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 1982 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2022/04/07 MEAN WIND SPEED = 5.06 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 45 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.050 0.605 0.454 0.000 0.000 0.000 0.000 0.000 1.110 NNE 0.000 0.000 0.151 0.000 0.000 0.000 0.000 0.000 0.000 0.151 NE 0.000 0.101 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.151 ENE 0.000 0.000 0.151 0.000 0.000 0.000 0.000 0.000 0.000 0.151 E 0.000 0.050 0.151 0.000 0.000 0.000 0.000 0.000 0.000 0.202 ESE 0.000 0.000 0.151 0.000 0.000 0.000 0.000 0.000 0.000 0.151 SE 0.000 0.000 0.555 0.303 0.404 0.050 0.000 0.000 0.000 1.312 SSE 0.000 0.101 0.303 0.101 0.404 0.858 0.000 0.000 0.000 1.766 S 0.000 0.202 0.151 0.050 0.000 0.050 0.000 0.000 0.000 0.454 SSW 0.000 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 SW 0.000 0.000 0.101 0.000 0.000 0.000 0.000 0.000 0.000 0.101 WSW 0.000 0.101 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.101 W 0.000 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 WNW 0.000 0.050 0.101 0.000 0.000 0.000 0.000 0.000 0.000 0.151 NW 0.000 0.000 0.050 0.050 0.000 0.000 0.000 0.000 0.000 0.101 NNW 0.000 0.000 0.101 0.151 0.000 0.000 0.000 0.000 0.000 0.252 SUBTOTAL 0.000 0.757 2.624 1.110 0.807 0.959 0.000 0.000 0.000 6.256 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 1995 TOTAL HOURS OF STABILITY CLASS G 124 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G 124 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 1982 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2022/04/07 MEAN WIND SPEED = 4.11 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 46 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data Table 6-B Ground Level Releases - 2nd Quarter JFD Joint Frequency Distribution In Percent Page 47 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.092 0.554 0.000 0.000 0.000 0.647 NNE 0.000 0.000 0.000 0.000 0.046 0.231 0.000 0.000 0.000 0.277 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.046 0.462 0.277 0.000 0.000 0.000 0.785 SSE 0.000 0.000 0.000 0.462 0.231 0.139 0.000 0.000 0.000 0.831 S 0.000 0.000 0.000 0.739 0.185 0.092 0.000 0.000 0.000 1.016 SSW 0.000 0.000 0.000 0.092 0.370 0.231 0.000 0.000 0.000 0.693 SW 0.000 0.000 0.000 0.323 0.092 0.046 0.000 0.000 0.000 0.462 WSW 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 W 0.000 0.000 0.000 0.000 0.046 0.508 0.139 0.000 0.000 0.693 WNW 0.000 0.000 0.000 0.000 0.092 0.185 0.139 0.000 0.000 0.416 NW 0.000 0.000 0.000 0.000 0.000 0.139 0.000 0.000 0.000 0.139 NNW 0.000 0.000 0.000 0.046 0.092 0.092 0.000 0.000 0.000 0.231 SUBTOTAL 0.000 0.000 0.000 1.709 1.709 2.540 0.277 0.000 0.000 6.236 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2165 TOTAL HOURS OF STABILITY CLASS A 135 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A 135 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2165 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2022/07/11 MEAN WIND SPEED = 7.34 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 48 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.046 0.323 0.231 0.000 0.000 0.000 0.600 NNE 0.000 0.000 0.000 0.000 0.139 0.185 0.000 0.000 0.000 0.323 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 SE 0.000 0.000 0.000 0.092 0.554 0.139 0.000 0.000 0.000 0.785 SSE 0.000 0.000 0.000 0.323 0.092 0.139 0.000 0.000 0.000 0.554 S 0.000 0.000 0.046 0.462 0.277 0.370 0.000 0.000 0.000 1.155 SSW 0.000 0.000 0.000 0.046 0.092 0.139 0.046 0.000 0.000 0.323 SW 0.000 0.000 0.092 0.323 0.092 0.139 0.000 0.000 0.000 0.647 WSW 0.000 0.000 0.046 0.231 0.277 0.000 0.000 0.000 0.000 0.554 W 0.000 0.000 0.000 0.416 0.370 0.139 0.000 0.000 0.000 0.924 WNW 0.000 0.000 0.000 0.000 0.139 0.231 0.323 0.000 0.000 0.693 NW 0.000 0.000 0.000 0.000 0.046 0.092 0.046 0.000 0.000 0.185 NNW 0.000 0.000 0.000 0.000 0.092 0.370 0.046 0.000 0.000 0.508 SUBTOTAL 0.000 0.000 0.185 1.940 2.540 2.171 0.462 0.000 0.000 7.298 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2165 TOTAL HOURS OF STABILITY CLASS B 158 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B 158 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2165 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2022/07/11 MEAN WIND SPEED = 7.08 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 49 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.046 0.139 0.231 0.000 0.000 0.000 0.416 NNE 0.000 0.000 0.000 0.046 0.185 0.046 0.046 0.000 0.000 0.323 NE 0.000 0.000 0.000 0.000 0.092 0.139 0.000 0.000 0.000 0.231 ENE 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 SE 0.000 0.000 0.046 0.554 0.185 0.092 0.000 0.000 0.000 0.878 SSE 0.000 0.000 0.185 0.323 0.185 0.139 0.000 0.000 0.000 0.831 S 0.000 0.000 0.046 0.370 0.185 0.323 0.000 0.000 0.000 0.924 SSW 0.000 0.000 0.046 0.092 0.092 0.323 0.092 0.000 0.000 0.647 SW 0.000 0.000 0.000 0.139 0.185 0.000 0.000 0.000 0.000 0.323 WSW 0.000 0.000 0.046 0.185 0.185 0.000 0.046 0.000 0.000 0.462 W 0.000 0.000 0.000 0.231 0.277 0.092 0.046 0.000 0.000 0.647 WNW 0.000 0.000 0.046 0.046 0.277 0.139 0.092 0.000 0.000 0.600 NW 0.000 0.000 0.000 0.000 0.092 0.277 0.092 0.000 0.000 0.462 NNW 0.000 0.000 0.000 0.000 0.092 0.416 0.000 0.000 0.000 0.508 SUBTOTAL 0.000 0.000 0.416 2.079 2.217 2.217 0.416 0.000 0.000 7.344 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2165 TOTAL HOURS OF STABILITY CLASS C 159 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 159 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2165 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2022/07/11 MEAN WIND SPEED = 6.88 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 50 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.139 0.508 0.600 0.185 0.000 0.000 0.000 1.432 NNE 0.000 0.000 0.092 0.554 0.554 0.370 0.000 0.000 0.000 1.570 NE 0.000 0.000 0.139 0.277 0.323 0.323 0.000 0.000 0.000 1.062 ENE 0.000 0.000 0.046 0.277 0.092 0.046 0.000 0.000 0.000 0.462 E 0.000 0.046 0.185 0.277 0.092 0.000 0.000 0.000 0.000 0.600 ESE 0.000 0.046 0.139 0.323 0.416 0.092 0.000 0.000 0.000 1.016 SE 0.000 0.000 0.693 1.801 1.570 0.600 0.046 0.000 0.000 4.711 SSE 0.000 0.000 0.554 1.062 0.739 0.600 0.000 0.000 0.000 2.956 S 0.000 0.000 0.785 0.970 0.878 3.141 0.231 0.046 0.000 6.051 SSW 0.000 0.000 0.508 0.647 0.277 1.478 0.277 0.000 0.000 3.187 SW 0.000 0.000 0.508 0.416 0.323 0.231 0.000 0.000 0.000 1.478 WSW 0.000 0.000 0.370 0.924 0.370 0.092 0.000 0.000 0.000 1.755 W 0.000 0.000 0.370 0.693 0.924 1.155 0.370 0.000 0.000 3.510 WNW 0.000 0.000 0.092 0.139 0.231 0.462 0.970 0.046 0.000 1.940 NW 0.000 0.000 0.185 0.416 0.554 0.970 0.508 0.000 0.000 2.633 NNW 0.000 0.000 0.323 0.554 0.554 0.970 0.000 0.000 0.000 2.402 SUBTOTAL 0.000 0.092 5.127 9.838 8.499 10.716 2.402 0.092 0.000 36.767 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2165 TOTAL HOURS OF STABILITY CLASS D 796 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D 796 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2165 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2022/07/11 MEAN WIND SPEED = 6.78 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 51 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.046 0.739 0.462 0.092 0.046 0.000 0.000 0.000 1.386 NNE 0.000 0.046 0.092 0.785 0.739 0.139 0.000 0.000 0.000 1.801 NE 0.000 0.046 0.370 0.508 0.462 0.000 0.000 0.000 0.000 1.386 ENE 0.000 0.000 0.139 0.277 0.046 0.046 0.000 0.000 0.000 0.508 E 0.000 0.000 0.554 0.277 0.000 0.000 0.000 0.000 0.000 0.831 ESE 0.000 0.000 0.647 1.293 0.231 0.000 0.000 0.000 0.000 2.171 SE 0.000 0.185 0.693 0.693 0.370 0.092 0.000 0.000 0.000 2.032 SSE 0.000 0.185 0.831 0.924 0.462 0.416 0.000 0.000 0.000 2.818 S 0.000 0.000 0.277 0.600 1.109 1.339 0.924 0.092 0.000 4.342 SSW 0.000 0.092 0.647 0.323 0.277 0.508 0.092 0.000 0.000 1.940 SW 0.000 0.277 0.416 0.092 0.046 0.092 0.000 0.000 0.000 0.924 WSW 0.000 0.000 0.370 0.139 0.000 0.000 0.000 0.000 0.000 0.508 W 0.000 0.000 0.139 0.185 0.046 0.046 0.000 0.000 0.000 0.416 WNW 0.000 0.000 0.185 0.046 0.000 0.000 0.046 0.000 0.000 0.277 NW 0.000 0.000 0.277 0.277 0.000 0.092 0.000 0.000 0.000 0.647 NNW 0.000 0.000 0.462 0.370 0.323 0.139 0.000 0.000 0.000 1.293 SUBTOTAL 0.000 0.878 6.836 7.252 4.203 2.956 1.062 0.092 0.000 23.279 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2165 TOTAL HOURS OF STABILITY CLASS E 504 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E 504 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2165 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2022/07/11 MEAN WIND SPEED = 5.23 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 52 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.046 1.016 0.462 0.046 0.000 0.000 0.000 0.000 1.570 NNE 0.000 0.139 0.785 0.508 0.185 0.046 0.000 0.000 0.000 1.663 NE 0.000 0.092 0.185 0.185 0.323 0.092 0.000 0.000 0.000 0.878 ENE 0.000 0.046 0.092 0.139 0.092 0.000 0.000 0.000 0.000 0.370 E 0.000 0.092 0.878 0.416 0.000 0.000 0.000 0.000 0.000 1.386 ESE 0.000 0.000 0.462 0.416 0.046 0.000 0.000 0.000 0.000 0.924 SE 0.000 0.092 0.831 0.231 0.046 0.000 0.000 0.000 0.000 1.201 SSE 0.000 0.139 0.139 0.416 0.370 0.462 0.000 0.000 0.000 1.524 S 0.000 0.139 0.092 0.092 0.046 0.139 0.046 0.000 0.000 0.554 SSW 0.000 0.092 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.139 SW 0.000 0.092 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.139 WSW 0.000 0.000 0.092 0.046 0.046 0.000 0.000 0.000 0.000 0.185 W 0.000 0.000 0.046 0.139 0.000 0.000 0.000 0.000 0.000 0.185 WNW 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 NW 0.000 0.046 0.092 0.046 0.000 0.000 0.000 0.000 0.000 0.185 NNW 0.000 0.092 0.508 0.277 0.092 0.046 0.000 0.000 0.000 1.016 SUBTOTAL 0.000 1.109 5.266 3.372 1.339 0.831 0.046 0.000 0.000 11.963 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2165 TOTAL HOURS OF STABILITY CLASS F 259 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F 259 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2165 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2022/07/11 MEAN WIND SPEED = 3.84 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 53 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.092 0.831 0.739 0.000 0.000 0.000 0.000 0.000 1.663 NNE 0.000 0.000 0.554 0.693 0.046 0.000 0.000 0.000 0.000 1.293 NE 0.000 0.231 0.739 0.231 0.000 0.000 0.000 0.000 0.000 1.201 ENE 0.000 0.046 0.554 0.323 0.000 0.000 0.000 0.000 0.000 0.924 E 0.000 0.092 0.231 0.046 0.000 0.000 0.000 0.000 0.000 0.370 ESE 0.000 0.046 0.092 0.046 0.000 0.000 0.000 0.000 0.000 0.185 SE 0.000 0.185 0.231 0.000 0.000 0.000 0.000 0.000 0.000 0.416 SSE 0.000 0.000 0.139 0.139 0.139 0.092 0.000 0.000 0.000 0.508 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.092 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.139 NNW 0.000 0.092 0.231 0.000 0.000 0.000 0.000 0.000 0.000 0.323 SUBTOTAL 0.000 0.970 3.649 2.217 0.185 0.092 0.000 0.000 0.000 7.113 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2165 TOTAL HOURS OF STABILITY CLASS G 154 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G 154 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2165 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2022/07/11 MEAN WIND SPEED = 2.96 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 54 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data Table 6-C Ground Level Releases - 3rd Quarter JFD Joint Frequency Distribution In Percent Page 55 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.500 0.000 0.000 0.000 0.500 NNE 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.045 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.091 0.182 0.136 0.000 0.000 0.000 0.409 SSE 0.000 0.000 0.045 0.682 0.091 0.000 0.000 0.000 0.000 0.819 S 0.000 0.000 0.000 1.046 0.773 0.091 0.000 0.000 0.000 1.911 SSW 0.000 0.000 0.045 0.819 1.137 0.409 0.000 0.000 0.000 2.411 SW 0.000 0.000 0.000 0.910 0.819 0.318 0.000 0.000 0.000 2.047 WSW 0.000 0.000 0.000 0.546 0.182 0.136 0.000 0.000 0.000 0.864 W 0.000 0.000 0.000 0.227 0.364 0.318 0.000 0.000 0.000 0.910 WNW 0.000 0.000 0.000 0.091 0.136 0.045 0.000 0.000 0.000 0.273 NW 0.000 0.000 0.000 0.045 0.000 0.045 0.045 0.000 0.000 0.136 NNW 0.000 0.000 0.000 0.000 0.000 0.091 0.045 0.000 0.000 0.136 SUBTOTAL 0.000 0.000 0.091 4.459 3.685 2.138 0.091 0.000 0.000 10.464 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2198 TOTAL HOURS OF STABILITY CLASS A 230 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A 230 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2198 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2022/10/12 MEAN WIND SPEED = 6.13 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 56 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.045 0.091 0.000 0.000 0.000 0.136 NNE 0.000 0.000 0.000 0.000 0.045 0.273 0.000 0.000 0.000 0.318 NE 0.000 0.000 0.000 0.000 0.000 0.136 0.000 0.000 0.000 0.136 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.637 0.318 0.000 0.000 0.000 0.000 0.955 SSE 0.000 0.000 0.045 0.500 0.000 0.000 0.000 0.000 0.000 0.546 S 0.000 0.000 0.045 0.637 0.091 0.000 0.000 0.000 0.000 0.773 SSW 0.000 0.000 0.136 0.318 0.136 0.045 0.000 0.000 0.000 0.637 SW 0.000 0.000 0.136 0.500 0.136 0.045 0.000 0.000 0.000 0.819 WSW 0.000 0.000 0.000 0.318 0.136 0.045 0.000 0.000 0.000 0.500 W 0.000 0.000 0.000 0.136 0.227 0.182 0.000 0.000 0.000 0.546 WNW 0.000 0.000 0.000 0.045 0.000 0.182 0.045 0.000 0.000 0.273 NW 0.000 0.000 0.000 0.000 0.045 0.045 0.045 0.000 0.000 0.136 NNW 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.091 SUBTOTAL 0.000 0.000 0.364 3.094 1.183 1.137 0.091 0.000 0.000 5.869 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2198 TOTAL HOURS OF STABILITY CLASS B 129 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B 129 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2198 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2022/10/12 MEAN WIND SPEED = 5.78 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 57 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.182 0.136 0.000 0.000 0.000 0.318 NNE 0.000 0.000 0.000 0.000 0.273 0.136 0.000 0.000 0.000 0.409 NE 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.045 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.045 SE 0.000 0.000 0.000 0.637 0.455 0.000 0.000 0.000 0.000 1.092 SSE 0.000 0.000 0.136 0.728 0.000 0.000 0.000 0.000 0.000 0.864 S 0.000 0.000 0.136 0.546 0.136 0.045 0.000 0.000 0.000 0.864 SSW 0.000 0.000 0.182 0.273 0.227 0.091 0.000 0.000 0.000 0.773 SW 0.000 0.000 0.227 0.364 0.227 0.045 0.000 0.000 0.000 0.864 WSW 0.000 0.000 0.045 0.455 0.091 0.045 0.000 0.000 0.000 0.637 W 0.000 0.000 0.000 0.182 0.227 0.091 0.000 0.000 0.000 0.500 WNW 0.000 0.000 0.000 0.000 0.045 0.182 0.000 0.000 0.000 0.227 NW 0.000 0.000 0.000 0.000 0.182 0.182 0.000 0.000 0.000 0.364 NNW 0.000 0.000 0.000 0.000 0.045 0.091 0.000 0.000 0.000 0.136 SUBTOTAL 0.000 0.000 0.773 3.185 2.093 1.092 0.000 0.000 0.000 7.143 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2198 TOTAL HOURS OF STABILITY CLASS C 157 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 157 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2198 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2022/10/12 MEAN WIND SPEED = 5.45 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 58 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.227 0.409 0.500 0.000 0.000 0.000 1.137 NNE 0.000 0.000 0.136 0.500 0.819 0.364 0.000 0.000 0.000 1.820 NE 0.000 0.045 0.364 0.318 0.364 0.273 0.091 0.000 0.000 1.456 ENE 0.000 0.000 0.182 0.409 0.136 0.045 0.000 0.000 0.000 0.773 E 0.000 0.000 0.227 0.318 0.273 0.000 0.000 0.000 0.000 0.819 ESE 0.000 0.000 0.500 0.591 0.455 0.000 0.000 0.000 0.000 1.547 SE 0.000 0.000 0.637 2.093 0.409 0.136 0.000 0.000 0.000 3.276 SSE 0.000 0.000 0.819 1.183 0.000 0.000 0.000 0.000 0.000 2.002 S 0.000 0.000 1.456 3.685 1.911 0.637 0.000 0.000 0.000 7.689 SSW 0.000 0.000 0.910 3.685 1.547 1.001 0.000 0.000 0.000 7.143 SW 0.000 0.000 1.865 1.592 0.227 0.136 0.000 0.000 0.000 3.822 WSW 0.000 0.000 1.001 1.683 0.273 0.182 0.000 0.000 0.000 3.139 W 0.000 0.000 0.182 0.409 1.001 0.227 0.000 0.000 0.000 1.820 WNW 0.000 0.000 0.000 0.091 0.227 0.227 0.000 0.000 0.000 0.546 NW 0.000 0.000 0.136 0.182 0.136 0.091 0.045 0.000 0.000 0.591 NNW 0.000 0.091 0.182 0.318 0.500 0.227 0.000 0.000 0.000 1.319 SUBTOTAL 0.000 0.136 8.599 17.288 8.690 4.049 0.136 0.000 0.000 38.899 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2198 TOTAL HOURS OF STABILITY CLASS D 855 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D 855 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2198 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2022/10/12 MEAN WIND SPEED = 4.95 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 59 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.728 0.318 0.091 0.136 0.000 0.000 0.000 1.274 NNE 0.000 0.000 0.682 1.274 0.773 0.273 0.000 0.000 0.000 3.003 NE 0.000 0.091 0.637 0.318 0.500 0.136 0.000 0.000 0.000 1.683 ENE 0.000 0.000 0.318 0.318 0.045 0.000 0.000 0.000 0.000 0.682 E 0.000 0.000 1.274 0.955 0.000 0.000 0.000 0.000 0.000 2.229 ESE 0.000 0.045 1.183 1.228 0.091 0.000 0.000 0.000 0.000 2.548 SE 0.000 0.000 1.001 0.227 0.000 0.000 0.000 0.000 0.000 1.228 SSE 0.000 0.045 0.819 0.182 0.045 0.000 0.000 0.000 0.000 1.092 S 0.000 0.000 0.910 0.819 0.318 0.136 0.000 0.000 0.000 2.184 SSW 0.000 0.091 0.409 0.546 0.409 0.000 0.000 0.000 0.000 1.456 SW 0.000 0.045 0.500 0.091 0.045 0.000 0.000 0.000 0.000 0.682 WSW 0.000 0.000 0.500 0.136 0.000 0.000 0.000 0.000 0.000 0.637 W 0.000 0.000 0.136 0.227 0.045 0.045 0.000 0.000 0.000 0.455 WNW 0.000 0.000 0.136 0.227 0.000 0.091 0.045 0.000 0.000 0.500 NW 0.000 0.000 0.182 0.045 0.091 0.091 0.000 0.000 0.000 0.409 NNW 0.000 0.091 0.318 0.227 0.136 0.000 0.000 0.000 0.000 0.773 SUBTOTAL 0.000 0.409 9.736 7.143 2.593 0.910 0.045 0.000 0.000 20.837 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2198 TOTAL HOURS OF STABILITY CLASS E 458 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E 458 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2198 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2022/10/12 MEAN WIND SPEED = 3.84 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 60 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.045 0.955 0.955 0.045 0.000 0.000 0.000 0.000 2.002 NNE 0.000 0.045 0.637 1.046 0.455 0.000 0.000 0.000 0.000 2.184 NE 0.000 0.136 0.409 0.045 0.045 0.000 0.000 0.000 0.000 0.637 ENE 0.000 0.091 0.591 0.546 0.000 0.000 0.000 0.000 0.000 1.228 E 0.000 0.045 0.682 0.728 0.045 0.000 0.000 0.000 0.000 1.501 ESE 0.000 0.045 0.182 0.227 0.045 0.000 0.000 0.000 0.000 0.500 SE 0.000 0.000 0.045 0.091 0.000 0.000 0.000 0.000 0.000 0.136 SSE 0.000 0.045 0.136 0.000 0.000 0.000 0.000 0.000 0.000 0.182 S 0.000 0.045 0.182 0.045 0.045 0.045 0.000 0.000 0.000 0.364 SSW 0.000 0.000 0.045 0.000 0.045 0.000 0.000 0.000 0.000 0.091 SW 0.000 0.000 0.182 0.000 0.000 0.000 0.000 0.000 0.000 0.182 WSW 0.000 0.136 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.227 W 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.045 WNW 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.091 NW 0.000 0.045 0.045 0.045 0.000 0.000 0.000 0.000 0.000 0.136 NNW 0.000 0.045 0.364 0.045 0.136 0.045 0.000 0.000 0.000 0.637 SUBTOTAL 0.000 0.728 4.686 3.776 0.864 0.091 0.000 0.000 0.000 10.146 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2198 TOTAL HOURS OF STABILITY CLASS F 223 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F 223 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2198 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2022/10/12 MEAN WIND SPEED = 3.39 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 61 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.182 1.137 0.819 0.000 0.000 0.000 0.000 0.000 2.138 NNE 0.000 0.182 0.910 0.318 0.273 0.000 0.000 0.000 0.000 1.683 NE 0.000 0.000 0.682 0.045 0.000 0.000 0.000 0.000 0.000 0.728 ENE 0.000 0.091 0.409 0.182 0.000 0.000 0.000 0.000 0.000 0.682 E 0.000 0.045 0.318 0.136 0.045 0.000 0.000 0.000 0.000 0.546 ESE 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.091 SE 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 SSE 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.045 S 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 SSW 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.045 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.091 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.045 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.091 NW 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.045 NNW 0.000 0.000 0.364 0.000 0.000 0.000 0.000 0.000 0.000 0.364 SUBTOTAL 0.000 0.728 4.049 1.501 0.318 0.045 0.000 0.000 0.000 6.642 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2198 TOTAL HOURS OF STABILITY CLASS G 146 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G 146 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2198 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2022/10/12 MEAN WIND SPEED = 2.88 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 62 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data Table 6-D Ground Level Releases - 4th Quarter JFD Joint Frequency Distribution In Percent Page 63 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.227 0.000 0.000 0.000 0.227 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.045 SE 0.000 0.000 0.000 0.091 0.409 0.091 0.000 0.000 0.000 0.591 SSE 0.000 0.000 0.000 0.136 0.045 0.000 0.000 0.000 0.000 0.182 S 0.000 0.000 0.136 0.091 0.000 0.000 0.000 0.000 0.000 0.227 SSW 0.000 0.000 0.000 0.227 0.000 0.000 0.000 0.000 0.000 0.227 SW 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.091 WSW 0.000 0.000 0.000 0.045 0.136 0.000 0.000 0.000 0.000 0.182 W 0.000 0.000 0.000 0.045 0.000 0.136 0.045 0.000 0.000 0.227 WNW 0.000 0.000 0.000 0.000 0.000 0.045 0.091 0.000 0.000 0.136 NW 0.000 0.000 0.000 0.000 0.000 0.136 0.045 0.000 0.000 0.182 NNW 0.000 0.000 0.000 0.000 0.000 0.409 0.045 0.000 0.000 0.455 SUBTOTAL 0.000 0.000 0.136 0.727 0.636 1.045 0.227 0.000 0.000 2.773 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2202 TOTAL HOURS OF STABILITY CLASS A 62 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A 61 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2200 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2023/01/05 MEAN WIND SPEED = 8.00 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 64 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.091 0.364 0.000 0.000 0.000 0.455 NNE 0.000 0.000 0.000 0.000 0.000 0.136 0.000 0.000 0.000 0.136 NE 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.045 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.045 SE 0.000 0.000 0.000 0.182 0.136 0.227 0.000 0.000 0.000 0.545 SSE 0.000 0.000 0.000 0.136 0.091 0.045 0.000 0.000 0.000 0.273 S 0.000 0.000 0.045 0.091 0.000 0.000 0.000 0.000 0.000 0.136 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.045 0.000 0.045 0.000 0.000 0.000 0.091 WSW 0.000 0.000 0.091 0.045 0.091 0.227 0.000 0.000 0.000 0.455 W 0.000 0.000 0.045 0.045 0.364 0.409 0.045 0.000 0.000 0.909 WNW 0.000 0.000 0.000 0.091 0.136 0.409 0.227 0.000 0.000 0.864 NW 0.000 0.000 0.000 0.000 0.091 0.364 0.045 0.000 0.000 0.500 NNW 0.000 0.000 0.000 0.000 0.045 0.136 0.045 0.000 0.000 0.227 SUBTOTAL 0.000 0.000 0.182 0.682 1.091 2.364 0.364 0.000 0.000 4.682 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2202 TOTAL HOURS OF STABILITY CLASS B 103 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B 103 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2200 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2023/01/05 MEAN WIND SPEED = 8.18 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 65 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.136 0.000 0.000 0.000 0.136 NNE 0.000 0.000 0.000 0.000 0.182 0.227 0.000 0.000 0.000 0.409 NE 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.091 ENE 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.045 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.182 0.500 0.182 0.000 0.000 0.000 0.864 SSE 0.000 0.000 0.091 0.182 0.091 0.000 0.000 0.000 0.000 0.364 S 0.000 0.000 0.136 0.045 0.136 0.000 0.000 0.000 0.000 0.318 SSW 0.000 0.000 0.000 0.182 0.000 0.000 0.000 0.000 0.000 0.182 SW 0.000 0.000 0.000 0.091 0.045 0.091 0.000 0.000 0.000 0.227 WSW 0.000 0.000 0.000 0.045 0.000 0.091 0.000 0.000 0.000 0.136 W 0.000 0.000 0.045 0.136 0.045 0.227 0.045 0.000 0.000 0.500 WNW 0.000 0.000 0.000 0.000 0.182 0.364 0.091 0.000 0.000 0.636 NW 0.000 0.000 0.000 0.000 0.136 0.318 0.091 0.000 0.000 0.545 NNW 0.000 0.000 0.000 0.000 0.000 0.591 0.000 0.000 0.000 0.591 SUBTOTAL 0.000 0.000 0.273 0.909 1.318 2.318 0.227 0.000 0.000 5.045 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2202 TOTAL HOURS OF STABILITY CLASS C 111 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 111 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2200 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2023/01/05 MEAN WIND SPEED = 7.57 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 66 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.409 0.182 0.318 0.318 0.000 0.000 0.000 1.227 NNE 0.000 0.000 0.182 0.500 0.818 0.182 0.000 0.000 0.000 1.682 NE 0.000 0.000 0.182 0.727 0.545 0.318 0.000 0.000 0.000 1.773 ENE 0.000 0.000 0.182 0.409 0.136 0.045 0.000 0.000 0.000 0.773 E 0.000 0.000 0.318 0.318 0.045 0.000 0.000 0.000 0.000 0.682 ESE 0.000 0.000 0.136 0.955 0.682 0.136 0.000 0.000 0.000 1.909 SE 0.000 0.000 0.182 1.136 1.045 2.091 0.182 0.000 0.000 4.636 SSE 0.000 0.000 0.409 0.500 0.773 0.545 0.000 0.000 0.000 2.227 S 0.000 0.000 0.409 0.409 0.364 0.727 0.045 0.000 0.000 1.955 SSW 0.000 0.000 0.318 0.273 0.045 0.227 0.000 0.000 0.000 0.864 SW 0.000 0.000 0.318 0.227 0.364 0.318 0.136 0.000 0.000 1.364 WSW 0.000 0.000 0.182 0.773 0.409 0.364 0.000 0.000 0.000 1.727 W 0.000 0.000 0.091 0.591 0.864 1.591 0.182 0.000 0.000 3.318 WNW 0.000 0.000 0.136 0.318 0.455 0.909 0.500 0.045 0.000 2.364 NW 0.000 0.000 0.091 0.318 0.636 1.636 0.409 0.318 0.045 3.455 NNW 0.000 0.045 0.136 0.455 0.773 1.955 0.045 0.000 0.000 3.409 SUBTOTAL 0.000 0.045 3.682 8.091 8.273 11.364 1.500 0.364 0.045 33.364 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2202 TOTAL HOURS OF STABILITY CLASS D 735 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D 734 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2200 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2023/01/05 MEAN WIND SPEED = 7.14 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 67 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.091 1.182 0.636 0.273 0.000 0.000 0.000 0.000 2.182 NNE 0.000 0.000 0.636 1.455 0.409 0.045 0.045 0.000 0.000 2.591 NE 0.000 0.045 0.727 0.727 0.364 0.000 0.000 0.000 0.000 1.864 ENE 0.000 0.000 0.727 0.364 0.136 0.000 0.000 0.000 0.000 1.227 E 0.000 0.045 0.818 0.818 0.091 0.091 0.000 0.000 0.000 1.864 ESE 0.000 0.000 0.818 1.773 0.727 0.136 0.000 0.000 0.000 3.455 SE 0.000 0.045 1.000 1.318 0.318 0.545 0.000 0.000 0.000 3.227 SSE 0.000 0.000 0.773 0.545 0.682 0.955 0.227 0.000 0.000 3.182 S 0.000 0.091 0.545 0.182 0.455 1.091 0.227 0.000 0.000 2.591 SSW 0.000 0.045 0.318 0.045 0.182 0.591 0.045 0.000 0.000 1.227 SW 0.000 0.000 0.318 0.182 0.136 0.136 0.000 0.000 0.000 0.773 WSW 0.000 0.000 0.227 0.091 0.136 0.000 0.000 0.000 0.000 0.455 W 0.000 0.091 0.318 0.455 0.227 0.045 0.000 0.000 0.000 1.136 WNW 0.000 0.000 0.000 0.182 0.136 0.091 0.000 0.000 0.000 0.409 NW 0.000 0.000 0.318 0.636 0.227 0.273 0.000 0.000 0.000 1.455 NNW 0.000 0.091 0.818 0.682 1.227 0.545 0.000 0.000 0.000 3.364 SUBTOTAL 0.000 0.545 9.545 10.091 5.727 4.545 0.545 0.000 0.000 31.000 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2202 TOTAL HOURS OF STABILITY CLASS E 682 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E 682 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2200 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2023/01/05 MEAN WIND SPEED = 5.04 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 68 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.045 0.727 0.955 0.000 0.000 0.000 0.000 0.000 1.727 NNE 0.000 0.000 0.500 0.909 0.136 0.000 0.000 0.000 0.000 1.545 NE 0.000 0.000 0.091 0.136 0.045 0.000 0.000 0.000 0.000 0.273 ENE 0.000 0.000 0.136 0.136 0.000 0.000 0.000 0.000 0.000 0.273 E 0.000 0.000 0.545 0.273 0.000 0.000 0.000 0.000 0.000 0.818 ESE 0.000 0.045 0.727 0.727 0.136 0.000 0.000 0.000 0.000 1.636 SE 0.000 0.045 0.500 0.591 0.455 0.227 0.000 0.000 0.000 1.818 SSE 0.000 0.000 0.318 0.727 0.409 0.682 0.091 0.000 0.000 2.227 S 0.000 0.000 0.136 0.091 0.182 0.227 0.000 0.000 0.000 0.636 SSW 0.000 0.000 0.273 0.136 0.000 0.000 0.000 0.000 0.000 0.409 SW 0.000 0.045 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.136 WSW 0.000 0.091 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.136 W 0.000 0.045 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.091 WNW 0.000 0.045 0.182 0.000 0.000 0.000 0.000 0.000 0.000 0.227 NW 0.000 0.045 0.182 0.045 0.000 0.000 0.000 0.000 0.000 0.273 NNW 0.000 0.091 0.409 0.455 0.091 0.000 0.000 0.000 0.000 1.045 SUBTOTAL 0.000 0.500 4.909 5.182 1.455 1.136 0.091 0.000 0.000 13.273 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2202 TOTAL HOURS OF STABILITY CLASS F 292 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F 292 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2200 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2023/01/05 MEAN WIND SPEED = 4.16 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 69 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.182 1.955 1.227 0.182 0.000 0.000 0.000 0.000 3.545 NNE 0.000 0.318 0.727 0.727 0.045 0.000 0.000 0.000 0.000 1.818 NE 0.000 0.136 0.364 0.182 0.000 0.000 0.000 0.000 0.000 0.682 ENE 0.000 0.045 0.364 0.273 0.000 0.000 0.000 0.000 0.000 0.682 E 0.000 0.000 0.273 0.045 0.000 0.000 0.000 0.000 0.000 0.318 ESE 0.000 0.000 0.045 0.091 0.000 0.000 0.000 0.000 0.000 0.136 SE 0.000 0.091 0.364 0.136 0.227 0.045 0.000 0.000 0.000 0.864 SSE 0.000 0.045 0.273 0.136 0.091 0.273 0.000 0.000 0.000 0.818 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.045 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.091 SW 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.091 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.045 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.091 WNW 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 NW 0.000 0.136 0.136 0.000 0.000 0.000 0.000 0.000 0.000 0.273 NNW 0.000 0.000 0.318 0.091 0.000 0.000 0.000 0.000 0.000 0.409 SUBTOTAL 0.000 1.091 5.000 2.909 0.545 0.318 0.000 0.000 0.000 9.864 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2202 TOTAL HOURS OF STABILITY CLASS G 217 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G 217 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2200 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2023/01/05 MEAN WIND SPEED = 3.22 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 70 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data Table 7-A Split Level Releases - 1st Quarter JFD Joint Frequency Distribution In Percent (Ground Level Release Mode and Elevated Release Mode)
Page 71 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.012 0.036 0.000 0.000 0.000 0.048 NNE 0.000 0.000 0.000 0.000 0.000 0.030 0.000 0.000 0.000 0.030 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.019 0.000 0.000 0.000 0.019 SE 0.000 0.000 0.000 0.005 0.027 0.051 0.046 0.000 0.000 0.129 SSE 0.000 0.000 0.000 0.000 0.009 0.048 0.000 0.000 0.000 0.057 S 0.000 0.000 0.000 0.000 0.035 0.000 0.000 0.000 0.000 0.035 SSW 0.000 0.000 0.000 0.000 0.030 0.000 0.000 0.000 0.000 0.030 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.027 0.000 0.000 0.027 WSW 0.000 0.000 0.000 0.002 0.009 0.000 0.000 0.000 0.000 0.012 W 0.000 0.000 0.000 0.000 0.006 0.000 0.012 0.000 0.000 0.018 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.051 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.022 0.000 0.000 0.022 NNW 0.000 0.000 0.000 0.000 0.000 0.036 0.025 0.000 0.000 0.061 SUBTOTAL 0.000 0.000 0.000 0.007 0.129 0.220 0.183 0.000 0.000 0.538 TOTAL HOURS OF VALID OBSERVATIONS 1811.000 TOTAL HOURS OF GROUND LEVEL RELEASE 273.330 TOTAL HOURS OF STABILITY CLASS A 9.750 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS A 9.750 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/04/07 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 72 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.021 0.168 0.000 0.000 0.000 0.189 NNE 0.000 0.000 0.000 0.000 0.014 0.042 0.000 0.000 0.000 0.056 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.008 0.013 0.009 0.000 0.000 0.000 0.029 SSE 0.000 0.000 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.009 S 0.000 0.000 0.000 0.000 0.005 0.000 0.000 0.000 0.000 0.005 SSW 0.000 0.000 0.000 0.000 0.005 0.000 0.000 0.000 0.000 0.005 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.018 0.007 0.023 0.000 0.000 0.047 W 0.000 0.000 0.000 0.000 0.005 0.039 0.011 0.000 0.000 0.055 WNW 0.000 0.000 0.000 0.000 0.003 0.021 0.018 0.076 0.000 0.118 NW 0.000 0.000 0.000 0.000 0.006 0.010 0.054 0.000 0.000 0.070 NNW 0.000 0.000 0.000 0.000 0.005 0.016 0.022 0.000 0.000 0.043 SUBTOTAL 0.000 0.000 0.000 0.008 0.103 0.311 0.128 0.076 0.000 0.627 TOTAL HOURS OF VALID OBSERVATIONS 1811.000 TOTAL HOURS OF GROUND LEVEL RELEASE 273.330 TOTAL HOURS OF STABILITY CLASS B 13.300 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS B 11.350 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/04/07 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 73 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.021 0.062 0.000 0.000 0.000 0.083 NNE 0.000 0.000 0.000 0.000 0.034 0.022 0.000 0.000 0.000 0.056 NE 0.000 0.000 0.000 0.000 0.002 0.009 0.000 0.000 0.000 0.012 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.004 0.000 0.000 0.000 0.000 0.004 SE 0.000 0.000 0.000 0.000 0.033 0.037 0.000 0.000 0.000 0.070 SSE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 S 0.000 0.000 0.000 0.003 0.000 0.019 0.000 0.000 0.000 0.022 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.000 0.003 0.000 0.034 0.000 0.000 0.037 WSW 0.000 0.000 0.000 0.005 0.008 0.034 0.017 0.000 0.000 0.064 W 0.000 0.000 0.000 0.000 0.015 0.040 0.041 0.000 0.000 0.097 WNW 0.000 0.000 0.000 0.000 0.003 0.052 0.065 0.035 0.000 0.155 NW 0.000 0.000 0.000 0.000 0.004 0.023 0.025 0.000 0.000 0.052 NNW 0.000 0.000 0.000 0.001 0.006 0.039 0.000 0.000 0.000 0.045 SUBTOTAL 0.000 0.000 0.000 0.009 0.132 0.337 0.182 0.035 0.000 0.696 TOTAL HOURS OF VALID OBSERVATIONS 1811.000 TOTAL HOURS OF GROUND LEVEL RELEASE 273.330 TOTAL HOURS OF STABILITY CLASS C 39.060 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS C 12.610 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/04/07 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 74 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.018 0.103 0.268 0.000 0.000 0.000 0.389 NNE 0.000 0.000 0.000 0.007 0.048 0.190 0.000 0.000 0.000 0.245 NE 0.000 0.000 0.000 0.001 0.033 0.046 0.000 0.000 0.000 0.080 ENE 0.000 0.000 0.000 0.001 0.036 0.046 0.000 0.000 0.000 0.083 E 0.000 0.000 0.001 0.015 0.047 0.035 0.000 0.000 0.000 0.098 ESE 0.000 0.000 0.000 0.031 0.055 0.039 0.000 0.000 0.000 0.125 SE 0.000 0.000 0.000 0.019 0.026 0.210 0.000 0.000 0.000 0.256 SSE 0.000 0.000 0.000 0.014 0.025 0.186 0.000 0.000 0.000 0.225 S 0.000 0.000 0.000 0.002 0.043 0.143 0.012 0.000 0.000 0.199 SSW 0.000 0.000 0.000 0.002 0.040 0.073 0.029 0.000 0.000 0.145 SW 0.000 0.000 0.000 0.010 0.010 0.116 0.020 0.000 0.000 0.157 WSW 0.000 0.000 0.000 0.006 0.044 0.120 0.000 0.000 0.000 0.170 W 0.000 0.000 0.000 0.002 0.038 0.265 0.022 0.000 0.000 0.327 WNW 0.000 0.000 0.000 0.002 0.025 0.155 0.260 0.125 0.000 0.567 NW 0.000 0.000 0.000 0.004 0.042 0.336 0.343 0.147 0.000 0.873 NNW 0.000 0.000 0.000 0.004 0.030 0.357 0.377 0.103 0.000 0.871 SUBTOTAL 0.000 0.000 0.001 0.139 0.645 2.586 1.064 0.375 0.000 4.809 TOTAL HOURS OF VALID OBSERVATIONS 1811.000 TOTAL HOURS OF GROUND LEVEL RELEASE 273.330 TOTAL HOURS OF STABILITY CLASS D 784.950 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS D 87.090 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/04/07 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 75 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.008 0.030 0.054 0.103 0.000 0.000 0.000 0.194 NNE 0.000 0.000 0.008 0.073 0.024 0.017 0.000 0.000 0.000 0.122 NE 0.000 0.000 0.007 0.041 0.038 0.067 0.000 0.000 0.000 0.154 ENE 0.000 0.000 0.012 0.019 0.034 0.000 0.000 0.000 0.000 0.065 E 0.000 0.000 0.002 0.036 0.015 0.020 0.000 0.000 0.000 0.075 ESE 0.000 0.000 0.008 0.047 0.025 0.010 0.000 0.000 0.000 0.091 SE 0.000 0.000 0.005 0.040 0.191 0.521 0.046 0.000 0.000 0.802 SSE 0.000 0.000 0.003 0.047 0.114 0.824 0.086 0.000 0.000 1.074 S 0.000 0.000 0.001 0.030 0.109 0.278 1.150 0.607 0.000 2.176 SSW 0.000 0.000 0.002 0.027 0.036 0.032 0.117 0.052 0.000 0.266 SW 0.000 0.000 0.000 0.013 0.016 0.033 0.000 0.000 0.000 0.062 WSW 0.000 0.000 0.004 0.006 0.008 0.009 0.000 0.000 0.000 0.027 W 0.000 0.000 0.005 0.031 0.028 0.000 0.000 0.000 0.000 0.064 WNW 0.000 0.000 0.000 0.032 0.013 0.027 0.022 0.000 0.000 0.093 NW 0.000 0.000 0.004 0.043 0.060 0.054 0.000 0.000 0.000 0.161 NNW 0.000 0.000 0.014 0.039 0.080 0.038 0.000 0.000 0.000 0.171 SUBTOTAL 0.000 0.000 0.083 0.553 0.845 2.034 1.420 0.659 0.000 5.595 TOTAL HOURS OF VALID OBSERVATIONS 1811.000 TOTAL HOURS OF GROUND LEVEL RELEASE 273.330 TOTAL HOURS OF STABILITY CLASS E 669.580 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS E 101.320 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/04/07 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 76 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.012 0.028 0.000 0.000 0.000 0.000 0.000 0.040 NNE 0.000 0.000 0.007 0.026 0.008 0.000 0.000 0.000 0.000 0.041 NE 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.009 ENE 0.000 0.000 0.012 0.021 0.000 0.000 0.000 0.000 0.000 0.033 E 0.000 0.000 0.068 0.056 0.000 0.000 0.000 0.000 0.000 0.125 ESE 0.000 0.000 0.041 0.051 0.018 0.000 0.000 0.000 0.000 0.110 SE 0.000 0.000 0.049 0.048 0.096 0.075 0.000 0.000 0.000 0.268 SSE 0.000 0.000 0.010 0.028 0.085 0.586 0.155 0.055 0.000 0.919 S 0.000 0.000 0.016 0.015 0.049 0.176 0.127 0.055 0.000 0.438 SSW 0.000 0.000 0.007 0.007 0.008 0.000 0.000 0.000 0.000 0.023 SW 0.000 0.000 0.003 0.000 0.024 0.011 0.000 0.000 0.000 0.038 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.007 0.004 0.000 0.000 0.000 0.000 0.000 0.011 WNW 0.000 0.000 0.000 0.006 0.000 0.000 0.000 0.000 0.000 0.006 NW 0.000 0.000 0.002 0.015 0.000 0.000 0.000 0.000 0.000 0.017 NNW 0.000 0.000 0.015 0.075 0.009 0.000 0.000 0.000 0.000 0.098 SUBTOTAL 0.000 0.000 0.258 0.379 0.297 0.848 0.282 0.110 0.000 2.175 TOTAL HOURS OF VALID OBSERVATIONS 1811.000 TOTAL HOURS OF GROUND LEVEL RELEASE 273.330 TOTAL HOURS OF STABILITY CLASS F 243.890 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS F 39.390 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/04/07 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 77 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.004 0.000 0.000 0.000 0.000 0.000 0.004 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.002 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.010 ESE 0.000 0.000 0.004 0.000 0.000 0.000 0.000 0.000 0.000 0.004 SE 0.000 0.000 0.033 0.049 0.080 0.019 0.000 0.000 0.000 0.182 SSE 0.000 0.001 0.009 0.018 0.083 0.273 0.000 0.000 0.000 0.384 S 0.000 0.001 0.010 0.008 0.000 0.029 0.000 0.000 0.000 0.049 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.003 0.000 0.000 0.000 0.000 0.000 0.000 0.003 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.007 0.000 0.000 0.000 0.000 0.000 0.007 NNW 0.000 0.000 0.000 0.008 0.000 0.000 0.000 0.000 0.000 0.008 SUBTOTAL 0.000 0.007 0.068 0.093 0.163 0.322 0.000 0.000 0.000 0.653 TOTAL HOURS OF VALID OBSERVATIONS 1811.000 TOTAL HOURS OF GROUND LEVEL RELEASE 273.330 TOTAL HOURS OF STABILITY CLASS G 50.470 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS G 11.820 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/04/07 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 78 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL HOURS OF VALID OBSERVATIONS 1811.000 TOTAL HOURS OF ELEVATED RELEASES 1537.670 TOTAL HOURS OF STABILITY CLASS A 9.750 TOTAL HOURS OF ELEVATED STABILITY CLASS A 0.000 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/04/07 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 79 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.009 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.000 0.000 0.000 0.000 0.049 0.000 0.000 0.000 0.049 S 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.050 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.099 0.000 0.000 0.009 0.108 TOTAL HOURS OF VALID OBSERVATIONS 1811.000 TOTAL HOURS OF ELEVATED RELEASES 1537.670 TOTAL HOURS OF STABILITY CLASS B 13.300 TOTAL HOURS OF ELEVATED STABILITY CLASS B 1.950 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/04/07 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 80 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.237 0.092 0.000 0.000 0.329 NNE 0.000 0.000 0.000 0.000 0.000 0.141 0.000 0.000 0.000 0.141 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.097 0.000 0.000 0.000 0.097 SE 0.000 0.000 0.000 0.000 0.055 0.000 0.000 0.000 0.000 0.055 SSE 0.000 0.000 0.000 0.000 0.000 0.047 0.135 0.000 0.000 0.182 S 0.000 0.000 0.000 0.000 0.000 0.099 0.000 0.000 0.000 0.099 SSW 0.000 0.000 0.000 0.000 0.000 0.144 0.000 0.000 0.000 0.144 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.051 0.150 0.087 0.000 0.000 0.288 W 0.000 0.000 0.000 0.000 0.000 0.000 0.044 0.024 0.000 0.068 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.056 0.000 0.056 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.000 0.107 0.916 0.358 0.080 0.000 1.461 TOTAL HOURS OF VALID OBSERVATIONS 1811.000 TOTAL HOURS OF ELEVATED RELEASES 1537.670 TOTAL HOURS OF STABILITY CLASS C 39.060 TOTAL HOURS OF ELEVATED STABILITY CLASS C 26.450 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/04/07 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 81 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.110 0.387 0.263 1.925 1.618 0.268 0.000 4.570 NNE 0.000 0.000 0.000 0.166 0.478 1.104 0.409 0.076 0.000 2.232 NE 0.000 0.000 0.000 0.276 0.163 0.293 0.000 0.000 0.000 0.732 ENE 0.000 0.000 0.000 0.000 0.108 0.192 0.045 0.000 0.000 0.346 E 0.000 0.000 0.055 0.000 0.269 0.632 0.092 0.000 0.000 1.048 ESE 0.000 0.000 0.055 0.442 0.315 1.015 0.226 0.036 0.000 2.090 SE 0.000 0.000 0.221 0.552 0.214 0.340 0.267 0.114 0.000 1.708 SSE 0.000 0.000 0.331 0.221 0.107 0.242 0.494 0.214 0.000 1.608 S 0.000 0.000 0.166 0.276 0.157 0.717 0.543 0.000 0.000 1.858 SSW 0.000 0.000 0.221 0.166 0.161 0.398 0.403 0.120 0.000 1.468 SW 0.000 0.000 0.166 0.110 0.208 0.243 0.494 0.107 0.000 1.328 WSW 0.000 0.000 0.110 0.276 0.318 0.959 0.496 0.039 0.000 2.197 W 0.000 0.000 0.497 0.939 0.795 1.350 1.218 0.000 0.000 4.797 WNW 0.000 0.000 0.000 0.828 0.644 1.263 0.980 0.418 0.023 4.155 NW 0.000 0.000 0.221 0.442 0.424 1.433 2.064 0.423 0.000 5.007 NNW 0.000 0.000 0.000 0.221 0.266 1.475 0.990 0.431 0.007 3.389 SUBTOTAL 0.000 0.000 2.154 5.301 4.888 13.581 10.336 2.245 0.030 38.535 TOTAL HOURS OF VALID OBSERVATIONS 1811.000 TOTAL HOURS OF ELEVATED RELEASES 1537.670 TOTAL HOURS OF STABILITY CLASS D 784.950 TOTAL HOURS OF ELEVATED STABILITY CLASS D 697.860 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/04/07 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 82 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.110 0.166 0.582 0.821 0.319 0.000 0.000 1.998 NNE 0.000 0.000 0.110 0.166 0.422 0.776 0.226 0.000 0.000 1.700 NE 0.000 0.000 0.055 0.221 0.263 0.833 0.137 0.000 0.000 1.510 ENE 0.000 0.000 0.055 0.331 0.266 0.582 0.045 0.000 0.000 1.279 E 0.000 0.000 0.055 0.497 0.161 0.590 0.090 0.000 0.000 1.393 ESE 0.000 0.000 0.110 0.276 0.533 0.783 0.179 0.129 0.000 2.011 SE 0.000 0.055 0.055 0.442 0.106 1.174 1.348 0.649 0.040 3.869 SSE 0.000 0.000 0.110 0.276 0.263 1.158 1.384 0.993 0.033 4.218 S 0.000 0.000 0.055 0.442 0.271 0.855 1.019 1.018 0.050 3.710 SSW 0.000 0.055 0.221 0.387 0.214 0.714 0.181 0.078 0.014 1.864 SW 0.000 0.000 0.166 0.276 0.220 0.433 0.134 0.000 0.000 1.228 WSW 0.000 0.000 0.221 0.221 0.269 0.000 0.045 0.000 0.000 0.755 W 0.000 0.000 0.166 0.607 0.467 0.493 0.044 0.000 0.000 1.777 WNW 0.000 0.000 0.055 0.000 0.214 0.441 0.089 0.036 0.000 0.835 NW 0.000 0.000 0.166 0.387 0.107 0.827 0.183 0.000 0.000 1.669 NNW 0.000 0.000 0.055 0.276 0.318 0.867 0.046 0.000 0.000 1.562 SUBTOTAL 0.000 0.110 1.767 4.970 4.676 11.348 5.468 2.902 0.137 31.378 TOTAL HOURS OF VALID OBSERVATIONS 1811.000 TOTAL HOURS OF ELEVATED RELEASES 1537.670 TOTAL HOURS OF STABILITY CLASS E 669.580 TOTAL HOURS OF ELEVATED STABILITY CLASS E 568.260 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/04/07 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 83 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.055 0.055 0.000 0.049 0.000 0.000 0.000 0.160 NNE 0.000 0.000 0.000 0.055 0.051 0.048 0.000 0.000 0.000 0.155 NE 0.000 0.000 0.055 0.055 0.053 0.000 0.000 0.000 0.000 0.163 ENE 0.000 0.000 0.110 0.166 0.158 0.199 0.000 0.000 0.000 0.634 E 0.000 0.000 0.000 0.055 0.213 0.199 0.000 0.000 0.000 0.467 ESE 0.000 0.000 0.055 0.166 0.210 0.979 0.046 0.000 0.000 1.456 SE 0.000 0.000 0.055 0.055 0.000 0.586 0.447 0.098 0.000 1.242 SSE 0.000 0.000 0.166 0.221 0.263 0.284 0.846 0.304 0.000 2.084 S 0.000 0.000 0.055 0.110 0.000 0.575 0.045 0.036 0.000 0.823 SSW 0.000 0.000 0.166 0.221 0.268 0.098 0.000 0.000 0.000 0.752 SW 0.000 0.000 0.276 0.276 0.264 0.000 0.000 0.000 0.000 0.817 WSW 0.000 0.000 0.110 0.331 0.273 0.050 0.000 0.000 0.000 0.765 W 0.000 0.000 0.166 0.166 0.110 0.000 0.000 0.000 0.000 0.442 WNW 0.000 0.000 0.110 0.166 0.054 0.100 0.000 0.000 0.000 0.430 NW 0.000 0.055 0.166 0.166 0.000 0.100 0.000 0.000 0.000 0.486 NNW 0.000 0.000 0.055 0.110 0.108 0.144 0.000 0.000 0.000 0.417 SUBTOTAL 0.000 0.055 1.601 2.374 2.027 3.411 1.384 0.439 0.000 11.292 TOTAL HOURS OF VALID OBSERVATIONS 1811.000 TOTAL HOURS OF ELEVATED RELEASES 1537.670 TOTAL HOURS OF STABILITY CLASS F 243.890 TOTAL HOURS OF ELEVATED STABILITY CLASS F 204.500 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/04/07 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 84 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.050 NNE 0.000 0.000 0.055 0.000 0.000 0.000 0.000 0.000 0.000 0.055 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.055 0.000 0.000 0.151 0.000 0.000 0.000 0.207 SE 0.000 0.000 0.000 0.055 0.155 0.151 0.000 0.000 0.000 0.361 SSE 0.000 0.000 0.000 0.000 0.000 0.146 0.000 0.000 0.000 0.146 S 0.000 0.000 0.000 0.166 0.052 0.000 0.000 0.000 0.000 0.218 SSW 0.000 0.000 0.110 0.000 0.000 0.000 0.000 0.000 0.000 0.110 SW 0.000 0.000 0.000 0.110 0.162 0.000 0.000 0.000 0.000 0.272 WSW 0.000 0.000 0.166 0.166 0.055 0.000 0.000 0.000 0.000 0.387 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.055 0.000 0.000 0.000 0.000 0.000 0.000 0.055 NW 0.000 0.000 0.055 0.055 0.000 0.000 0.000 0.000 0.000 0.110 NNW 0.000 0.055 0.000 0.055 0.053 0.000 0.000 0.000 0.000 0.163 SUBTOTAL 0.000 0.055 0.497 0.607 0.477 0.498 0.000 0.000 0.000 2.134 TOTAL HOURS OF VALID OBSERVATIONS 1811.000 TOTAL HOURS OF ELEVATED RELEASES 1537.670 TOTAL HOURS OF STABILITY CLASS G 50.470 TOTAL HOURS OF ELEVATED STABILITY CLASS G 38.650 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/04/07 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 85 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data Table 7-B Split Level Releases - 2nd Quarter JFD Joint Frequency Distribution In Percent (Ground Level Release Mode and Elevated Release Mode)
Page 86 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.007 0.086 0.000 0.000 0.000 0.094 NNE 0.000 0.000 0.000 0.000 0.002 0.037 0.000 0.000 0.000 0.039 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.004 0.067 0.052 0.000 0.000 0.000 0.123 SSE 0.000 0.000 0.000 0.034 0.035 0.046 0.000 0.000 0.000 0.115 S 0.000 0.000 0.000 0.036 0.026 0.017 0.000 0.000 0.000 0.079 SSW 0.000 0.000 0.000 0.003 0.041 0.041 0.000 0.000 0.000 0.085 SW 0.000 0.000 0.000 0.010 0.010 0.008 0.000 0.000 0.000 0.027 WSW 0.000 0.000 0.000 0.000 0.000 0.005 0.000 0.000 0.000 0.005 W 0.000 0.000 0.000 0.000 0.000 0.063 0.027 0.000 0.000 0.091 WNW 0.000 0.000 0.000 0.000 0.008 0.026 0.032 0.000 0.000 0.066 NW 0.000 0.000 0.000 0.000 0.000 0.022 0.000 0.000 0.000 0.022 NNW 0.000 0.000 0.000 0.000 0.010 0.015 0.000 0.000 0.000 0.025 SUBTOTAL 0.000 0.000 0.000 0.087 0.207 0.417 0.060 0.000 0.000 0.770 TOTAL HOURS OF VALID OBSERVATIONS 2165.000 TOTAL HOURS OF GROUND LEVEL RELEASE 251.730 TOTAL HOURS OF STABILITY CLASS A 17.520 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS A 16.680 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/07/11 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 87 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.024 0.035 0.000 0.000 0.000 0.059 NNE 0.000 0.000 0.000 0.000 0.014 0.024 0.000 0.000 0.000 0.038 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.006 0.000 0.000 0.000 0.000 0.006 SE 0.000 0.000 0.000 0.001 0.059 0.050 0.000 0.000 0.000 0.110 SSE 0.000 0.000 0.000 0.003 0.015 0.065 0.000 0.000 0.000 0.083 S 0.000 0.000 0.000 0.006 0.043 0.079 0.000 0.000 0.000 0.127 SSW 0.000 0.000 0.000 0.000 0.010 0.027 0.024 0.000 0.000 0.062 SW 0.000 0.000 0.000 0.000 0.004 0.029 0.000 0.000 0.000 0.033 WSW 0.000 0.000 0.000 0.000 0.018 0.000 0.000 0.000 0.000 0.018 W 0.000 0.000 0.000 0.000 0.018 0.016 0.000 0.000 0.000 0.035 WNW 0.000 0.000 0.000 0.000 0.009 0.034 0.062 0.000 0.000 0.105 NW 0.000 0.000 0.000 0.000 0.004 0.016 0.025 0.000 0.000 0.045 NNW 0.000 0.000 0.000 0.000 0.007 0.051 0.009 0.000 0.000 0.067 SUBTOTAL 0.000 0.000 0.000 0.010 0.232 0.425 0.121 0.000 0.000 0.788 TOTAL HOURS OF VALID OBSERVATIONS 2165.000 TOTAL HOURS OF GROUND LEVEL RELEASE 251.730 TOTAL HOURS OF STABILITY CLASS B 43.510 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS B 17.060 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/07/11 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 88 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.014 0.033 0.000 0.000 0.000 0.047 NNE 0.000 0.000 0.000 0.000 0.012 0.006 0.019 0.000 0.000 0.038 NE 0.000 0.000 0.000 0.000 0.009 0.015 0.000 0.000 0.000 0.024 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.006 0.000 0.000 0.000 0.000 0.006 SE 0.000 0.000 0.000 0.023 0.022 0.018 0.000 0.000 0.000 0.063 SSE 0.000 0.000 0.000 0.012 0.031 0.088 0.000 0.000 0.000 0.132 S 0.000 0.000 0.000 0.004 0.030 0.060 0.000 0.000 0.000 0.094 SSW 0.000 0.000 0.000 0.000 0.012 0.067 0.033 0.000 0.000 0.112 SW 0.000 0.000 0.000 0.004 0.016 0.000 0.000 0.000 0.000 0.020 WSW 0.000 0.000 0.000 0.001 0.006 0.000 0.022 0.000 0.000 0.030 W 0.000 0.000 0.000 0.001 0.019 0.009 0.024 0.000 0.000 0.054 WNW 0.000 0.000 0.000 0.000 0.018 0.017 0.021 0.000 0.000 0.056 NW 0.000 0.000 0.000 0.000 0.006 0.040 0.018 0.000 0.000 0.064 NNW 0.000 0.000 0.000 0.000 0.007 0.055 0.000 0.000 0.000 0.063 SUBTOTAL 0.000 0.000 0.000 0.045 0.211 0.409 0.138 0.000 0.000 0.802 TOTAL HOURS OF VALID OBSERVATIONS 2165.000 TOTAL HOURS OF GROUND LEVEL RELEASE 251.730 TOTAL HOURS OF STABILITY CLASS C 97.830 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS C 17.370 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/07/11 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 89 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.004 0.030 0.075 0.031 0.000 0.000 0.000 0.140 NNE 0.000 0.000 0.000 0.018 0.050 0.055 0.000 0.000 0.000 0.123 NE 0.000 0.000 0.000 0.010 0.025 0.046 0.000 0.000 0.000 0.081 ENE 0.000 0.000 0.000 0.006 0.005 0.007 0.000 0.000 0.000 0.018 E 0.000 0.000 0.000 0.002 0.009 0.000 0.000 0.000 0.000 0.011 ESE 0.000 0.000 0.000 0.021 0.061 0.028 0.000 0.000 0.000 0.110 SE 0.000 0.000 0.004 0.066 0.249 0.226 0.040 0.000 0.000 0.585 SSE 0.000 0.000 0.003 0.101 0.149 0.287 0.000 0.000 0.000 0.540 S 0.000 0.000 0.001 0.080 0.140 0.674 0.072 0.044 0.000 1.012 SSW 0.000 0.000 0.000 0.024 0.030 0.280 0.119 0.000 0.000 0.454 SW 0.000 0.000 0.000 0.011 0.043 0.041 0.000 0.000 0.000 0.095 WSW 0.000 0.000 0.000 0.024 0.038 0.016 0.000 0.000 0.000 0.079 W 0.000 0.000 0.000 0.024 0.095 0.182 0.129 0.000 0.000 0.431 WNW 0.000 0.000 0.000 0.000 0.017 0.065 0.264 0.028 0.000 0.375 NW 0.000 0.000 0.000 0.007 0.049 0.168 0.135 0.000 0.000 0.358 NNW 0.000 0.000 0.001 0.017 0.060 0.165 0.000 0.000 0.000 0.242 SUBTOTAL 0.000 0.000 0.013 0.442 1.097 2.273 0.759 0.072 0.000 4.655 TOTAL HOURS OF VALID OBSERVATIONS 2165.000 TOTAL HOURS OF GROUND LEVEL RELEASE 251.730 TOTAL HOURS OF STABILITY CLASS D 1097.740 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS D 100.780 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/07/11 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 90 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.016 0.051 0.011 0.007 0.000 0.000 0.000 0.085 NNE 0.000 0.000 0.002 0.085 0.104 0.022 0.000 0.000 0.000 0.213 NE 0.000 0.000 0.006 0.037 0.057 0.000 0.000 0.000 0.000 0.100 ENE 0.000 0.000 0.003 0.021 0.007 0.008 0.000 0.000 0.000 0.039 E 0.000 0.000 0.009 0.023 0.000 0.000 0.000 0.000 0.000 0.032 ESE 0.000 0.000 0.017 0.138 0.035 0.000 0.000 0.000 0.000 0.189 SE 0.000 0.000 0.040 0.097 0.068 0.041 0.000 0.000 0.000 0.246 SSE 0.000 0.001 0.084 0.145 0.086 0.187 0.000 0.000 0.000 0.503 S 0.000 0.000 0.006 0.065 0.192 0.273 0.548 0.092 0.000 1.176 SSW 0.000 0.000 0.000 0.022 0.040 0.089 0.019 0.000 0.000 0.170 SW 0.000 0.000 0.000 0.006 0.007 0.018 0.000 0.000 0.000 0.030 WSW 0.000 0.000 0.003 0.006 0.000 0.000 0.000 0.000 0.000 0.009 W 0.000 0.000 0.000 0.009 0.006 0.007 0.000 0.000 0.000 0.022 WNW 0.000 0.000 0.000 0.002 0.000 0.000 0.009 0.000 0.000 0.011 NW 0.000 0.000 0.002 0.014 0.000 0.017 0.000 0.000 0.000 0.032 NNW 0.000 0.000 0.005 0.032 0.045 0.024 0.000 0.000 0.000 0.106 SUBTOTAL 0.000 0.001 0.192 0.752 0.658 0.693 0.576 0.092 0.000 2.964 TOTAL HOURS OF VALID OBSERVATIONS 2165.000 TOTAL HOURS OF GROUND LEVEL RELEASE 251.730 TOTAL HOURS OF STABILITY CLASS E 561.120 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS E 64.180 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/07/11 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 91 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.067 0.062 0.008 0.000 0.000 0.000 0.000 0.137 NNE 0.000 0.000 0.017 0.068 0.032 0.008 0.000 0.000 0.000 0.125 NE 0.000 0.000 0.001 0.021 0.051 0.016 0.000 0.000 0.000 0.089 ENE 0.000 0.004 0.000 0.012 0.015 0.000 0.000 0.000 0.000 0.031 E 0.000 0.000 0.042 0.042 0.000 0.000 0.000 0.000 0.000 0.084 ESE 0.000 0.000 0.036 0.053 0.007 0.000 0.000 0.000 0.000 0.096 SE 0.000 0.000 0.072 0.030 0.007 0.000 0.000 0.000 0.000 0.109 SSE 0.000 0.000 0.020 0.070 0.080 0.140 0.000 0.000 0.000 0.311 S 0.000 0.000 0.009 0.014 0.008 0.028 0.013 0.000 0.000 0.073 SSW 0.000 0.000 0.000 0.000 0.000 0.016 0.000 0.000 0.000 0.016 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.006 0.006 0.000 0.000 0.000 0.000 0.012 W 0.000 0.000 0.001 0.011 0.000 0.000 0.000 0.000 0.000 0.012 WNW 0.000 0.000 0.000 0.000 0.004 0.000 0.000 0.000 0.000 0.004 NW 0.000 0.000 0.000 0.002 0.000 0.000 0.000 0.000 0.000 0.002 NNW 0.000 0.000 0.034 0.033 0.015 0.008 0.000 0.000 0.000 0.090 SUBTOTAL 0.000 0.005 0.299 0.422 0.234 0.217 0.013 0.000 0.000 1.190 TOTAL HOURS OF VALID OBSERVATIONS 2165.000 TOTAL HOURS OF GROUND LEVEL RELEASE 251.730 TOTAL HOURS OF STABILITY CLASS F 274.100 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS F 25.770 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/07/11 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 92 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.047 0.069 0.000 0.000 0.000 0.000 0.000 0.115 NNE 0.000 0.000 0.005 0.069 0.008 0.000 0.000 0.000 0.000 0.082 NE 0.000 0.000 0.009 0.028 0.000 0.000 0.000 0.000 0.000 0.036 ENE 0.000 0.000 0.018 0.030 0.000 0.000 0.000 0.000 0.000 0.048 E 0.000 0.006 0.006 0.005 0.000 0.000 0.000 0.000 0.000 0.017 ESE 0.000 0.005 0.006 0.005 0.000 0.000 0.000 0.000 0.000 0.016 SE 0.000 0.018 0.018 0.000 0.000 0.000 0.000 0.000 0.000 0.036 SSE 0.000 0.000 0.020 0.025 0.027 0.030 0.000 0.000 0.000 0.102 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.001 NNW 0.000 0.000 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.002 SUBTOTAL 0.000 0.030 0.132 0.230 0.035 0.030 0.000 0.000 0.000 0.457 TOTAL HOURS OF VALID OBSERVATIONS 2165.000 TOTAL HOURS OF GROUND LEVEL RELEASE 251.730 TOTAL HOURS OF STABILITY CLASS G 73.180 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS G 9.890 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/07/11 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 93 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.039 0.000 0.000 0.000 0.039 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.039 0.000 0.000 0.000 0.039 TOTAL HOURS OF VALID OBSERVATIONS 2165.000 TOTAL HOURS OF ELEVATED RELEASES 1913.270 TOTAL HOURS OF STABILITY CLASS A 17.520 TOTAL HOURS OF ELEVATED STABILITY CLASS A 0.840 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/07/11 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 94 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.117 0.152 0.000 0.000 0.270 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.000 0.000 0.092 0.045 0.121 0.000 0.000 0.000 0.258 S 0.000 0.000 0.000 0.000 0.000 0.042 0.000 0.000 0.000 0.042 SSW 0.000 0.000 0.000 0.000 0.000 0.042 0.000 0.000 0.000 0.042 SW 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.285 0.000 0.000 0.000 0.285 WNW 0.000 0.000 0.000 0.000 0.000 0.164 0.000 0.000 0.000 0.164 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.038 0.000 0.000 0.038 NNW 0.000 0.000 0.000 0.000 0.000 0.039 0.038 0.000 0.000 0.077 SUBTOTAL 0.000 0.000 0.000 0.139 0.045 0.809 0.229 0.000 0.000 1.222 TOTAL HOURS OF VALID OBSERVATIONS 2165.000 TOTAL HOURS OF ELEVATED RELEASES 1913.270 TOTAL HOURS OF STABILITY CLASS B 43.510 TOTAL HOURS OF ELEVATED STABILITY CLASS B 26.450 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/07/11 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 95 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.089 0.443 0.076 0.000 0.000 0.609 NNE 0.000 0.000 0.000 0.000 0.090 0.201 0.038 0.000 0.000 0.329 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.041 0.000 0.000 0.000 0.041 SE 0.000 0.000 0.000 0.046 0.000 0.163 0.075 0.000 0.000 0.284 SSE 0.000 0.000 0.000 0.139 0.091 0.164 0.037 0.000 0.000 0.430 S 0.000 0.000 0.000 0.000 0.000 0.040 0.000 0.000 0.000 0.040 SSW 0.000 0.000 0.000 0.000 0.131 0.120 0.000 0.000 0.000 0.251 SW 0.000 0.000 0.000 0.000 0.000 0.041 0.115 0.000 0.000 0.156 WSW 0.000 0.000 0.000 0.092 0.090 0.083 0.000 0.000 0.000 0.265 W 0.000 0.000 0.000 0.185 0.136 0.322 0.148 0.033 0.000 0.824 WNW 0.000 0.000 0.000 0.000 0.000 0.085 0.113 0.000 0.000 0.198 NW 0.000 0.000 0.000 0.000 0.000 0.039 0.000 0.000 0.000 0.039 NNW 0.000 0.000 0.000 0.000 0.091 0.121 0.038 0.000 0.000 0.250 SUBTOTAL 0.000 0.000 0.000 0.462 0.717 1.863 0.642 0.033 0.000 3.716 TOTAL HOURS OF VALID OBSERVATIONS 2165.000 TOTAL HOURS OF ELEVATED RELEASES 1913.270 TOTAL HOURS OF STABILITY CLASS C 97.830 TOTAL HOURS OF ELEVATED STABILITY CLASS C 80.460 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/07/11 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 96 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.092 0.758 1.495 0.265 0.000 0.000 2.610 NNE 0.000 0.000 0.000 0.231 0.447 0.944 0.115 0.027 0.000 1.763 NE 0.000 0.000 0.046 0.046 0.175 0.248 0.000 0.000 0.000 0.515 ENE 0.000 0.000 0.000 0.139 0.311 0.039 0.000 0.000 0.000 0.489 E 0.000 0.000 0.185 0.277 0.222 0.040 0.000 0.000 0.000 0.724 ESE 0.000 0.000 0.139 0.092 0.398 0.767 0.229 0.025 0.000 1.651 SE 0.000 0.000 0.370 1.386 0.852 1.411 1.383 0.573 0.027 6.001 SSE 0.000 0.000 0.185 0.970 0.757 1.097 1.539 0.535 0.008 5.090 S 0.000 0.000 0.370 0.647 0.444 0.808 2.730 0.247 0.002 5.248 SSW 0.000 0.046 0.416 0.647 0.402 1.124 1.569 0.370 0.000 4.573 SW 0.000 0.000 0.185 0.970 0.316 0.820 0.448 0.036 0.000 2.775 WSW 0.000 0.000 0.185 0.924 0.716 0.415 0.038 0.024 0.000 2.302 W 0.000 0.000 0.185 0.785 1.073 1.670 0.752 0.201 0.000 4.667 WNW 0.000 0.000 0.139 0.231 0.267 0.745 0.712 0.406 0.000 2.499 NW 0.000 0.000 0.046 0.277 0.482 0.931 1.016 0.141 0.000 2.893 NNW 0.000 0.000 0.046 0.185 0.357 1.207 0.454 0.000 0.000 2.249 SUBTOTAL 0.000 0.046 2.494 7.898 7.977 13.763 11.248 2.584 0.037 46.049 TOTAL HOURS OF VALID OBSERVATIONS 2165.000 TOTAL HOURS OF ELEVATED RELEASES 1913.270 TOTAL HOURS OF STABILITY CLASS D 1097.740 TOTAL HOURS OF ELEVATED STABILITY CLASS D 996.960 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/07/11 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 97 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.046 0.370 0.353 0.654 0.115 0.000 0.000 1.538 NNE 0.000 0.000 0.092 0.139 0.224 1.170 0.115 0.000 0.000 1.739 NE 0.000 0.000 0.046 0.092 0.311 0.697 0.038 0.000 0.000 1.185 ENE 0.000 0.000 0.092 0.046 0.224 0.325 0.000 0.000 0.000 0.687 E 0.000 0.000 0.000 0.139 0.268 0.291 0.000 0.000 0.000 0.698 ESE 0.000 0.000 0.231 0.185 0.400 0.410 0.115 0.000 0.000 1.341 SE 0.000 0.000 0.185 0.231 0.311 1.338 0.494 0.058 0.000 2.617 SSE 0.000 0.000 0.139 0.185 0.269 0.916 1.990 0.382 0.001 3.882 S 0.000 0.000 0.139 0.370 0.221 0.875 0.749 0.448 0.035 2.835 SSW 0.000 0.000 0.277 0.462 0.307 0.197 0.187 0.068 0.003 1.501 SW 0.000 0.046 0.139 0.554 0.226 0.000 0.075 0.000 0.000 1.040 WSW 0.000 0.000 0.231 0.185 0.271 0.000 0.000 0.000 0.000 0.686 W 0.000 0.000 0.046 0.370 0.133 0.250 0.000 0.000 0.000 0.799 WNW 0.000 0.000 0.046 0.046 0.224 0.042 0.037 0.000 0.000 0.396 NW 0.000 0.000 0.185 0.092 0.133 0.481 0.114 0.000 0.000 1.005 NNW 0.000 0.046 0.000 0.277 0.399 0.245 0.038 0.000 0.000 1.006 SUBTOTAL 0.000 0.092 1.894 3.741 4.273 7.892 4.066 0.956 0.038 22.953 TOTAL HOURS OF VALID OBSERVATIONS 2165.000 TOTAL HOURS OF ELEVATED RELEASES 1913.270 TOTAL HOURS OF STABILITY CLASS E 561.120 TOTAL HOURS OF ELEVATED STABILITY CLASS E 496.940 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/07/11 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 98 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.046 0.046 0.357 0.847 0.000 0.000 0.000 1.297 NNE 0.000 0.000 0.000 0.046 0.135 0.402 0.267 0.000 0.000 0.850 NE 0.000 0.000 0.046 0.185 0.044 0.281 0.115 0.000 0.000 0.671 ENE 0.000 0.000 0.046 0.046 0.397 0.485 0.115 0.000 0.000 1.089 E 0.000 0.000 0.185 0.139 0.267 0.331 0.000 0.000 0.000 0.922 ESE 0.000 0.000 0.046 0.139 0.403 0.448 0.000 0.000 0.000 1.036 SE 0.000 0.000 0.185 0.277 0.271 0.733 0.000 0.000 0.000 1.467 SSE 0.000 0.000 0.046 0.185 0.046 0.449 0.149 0.062 0.000 0.938 S 0.000 0.000 0.185 0.139 0.086 0.281 0.000 0.030 0.000 0.721 SSW 0.000 0.000 0.139 0.046 0.046 0.122 0.000 0.000 0.000 0.353 SW 0.000 0.000 0.046 0.046 0.000 0.040 0.000 0.000 0.000 0.133 WSW 0.000 0.000 0.139 0.139 0.046 0.041 0.000 0.000 0.000 0.364 W 0.000 0.000 0.370 0.139 0.000 0.125 0.000 0.000 0.000 0.633 WNW 0.000 0.000 0.092 0.000 0.089 0.000 0.000 0.000 0.000 0.182 NW 0.000 0.000 0.046 0.139 0.087 0.122 0.000 0.000 0.000 0.394 NNW 0.000 0.000 0.000 0.000 0.177 0.245 0.000 0.000 0.000 0.422 SUBTOTAL 0.000 0.000 1.617 1.709 2.452 4.953 0.646 0.093 0.000 11.470 TOTAL HOURS OF VALID OBSERVATIONS 2165.000 TOTAL HOURS OF ELEVATED RELEASES 1913.270 TOTAL HOURS OF STABILITY CLASS F 274.100 TOTAL HOURS OF ELEVATED STABILITY CLASS F 248.330 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/07/11 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 99 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.046 0.000 0.000 0.084 0.000 0.000 0.000 0.130 NNE 0.000 0.000 0.046 0.000 0.046 0.275 0.000 0.000 0.000 0.367 NE 0.000 0.000 0.092 0.046 0.135 0.200 0.000 0.000 0.000 0.474 ENE 0.000 0.000 0.000 0.185 0.045 0.083 0.000 0.000 0.000 0.312 E 0.000 0.000 0.000 0.000 0.000 0.251 0.000 0.000 0.000 0.251 ESE 0.000 0.000 0.185 0.000 0.044 0.000 0.000 0.000 0.000 0.229 SE 0.000 0.000 0.092 0.046 0.270 0.166 0.000 0.000 0.000 0.575 SSE 0.000 0.000 0.092 0.000 0.000 0.042 0.000 0.000 0.000 0.134 S 0.000 0.000 0.046 0.092 0.000 0.039 0.000 0.000 0.000 0.178 SSW 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.139 0.000 0.000 0.000 0.000 0.000 0.000 0.139 W 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.043 0.000 0.000 0.000 0.000 0.043 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.785 0.416 0.582 1.140 0.000 0.000 0.000 2.923 TOTAL HOURS OF VALID OBSERVATIONS 2165.000 TOTAL HOURS OF ELEVATED RELEASES 1913.270 TOTAL HOURS OF STABILITY CLASS G 73.180 TOTAL HOURS OF ELEVATED STABILITY CLASS G 63.290 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/07/11 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 100 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data Table 7-C Split Level Releases - 3rd Quarter JFD Joint Frequency Distribution In Percent (Ground Level Release Mode and Elevated Release Mode)
Page 101 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.091 NNE 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.000 0.000 0.009 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.005 0.016 0.025 0.000 0.000 0.000 0.046 SSE 0.000 0.000 0.000 0.034 0.007 0.000 0.000 0.000 0.000 0.040 S 0.000 0.000 0.000 0.043 0.088 0.014 0.000 0.000 0.000 0.145 SSW 0.000 0.000 0.000 0.017 0.126 0.071 0.000 0.000 0.000 0.215 SW 0.000 0.000 0.000 0.015 0.083 0.051 0.000 0.000 0.000 0.150 WSW 0.000 0.000 0.000 0.000 0.014 0.019 0.000 0.000 0.000 0.033 W 0.000 0.000 0.000 0.000 0.019 0.041 0.000 0.000 0.000 0.061 WNW 0.000 0.000 0.000 0.000 0.005 0.005 0.000 0.000 0.000 0.010 NW 0.000 0.000 0.000 0.001 0.000 0.004 0.009 0.000 0.000 0.015 NNW 0.000 0.000 0.000 0.000 0.000 0.013 0.009 0.000 0.000 0.022 SUBTOTAL 0.000 0.000 0.000 0.116 0.359 0.344 0.018 0.000 0.000 0.837 TOTAL HOURS OF VALID OBSERVATIONS 2198.000 TOTAL HOURS OF GROUND LEVEL RELEASE 141.860 TOTAL HOURS OF STABILITY CLASS A 23.780 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS A 18.400 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/10/12 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 102 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.005 0.015 0.000 0.000 0.000 0.020 NNE 0.000 0.000 0.000 0.000 0.004 0.047 0.000 0.000 0.000 0.051 NE 0.000 0.000 0.000 0.000 0.000 0.023 0.000 0.000 0.000 0.023 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.008 0.035 0.000 0.000 0.000 0.000 0.043 SSE 0.000 0.000 0.000 0.008 0.000 0.000 0.000 0.000 0.000 0.008 S 0.000 0.000 0.000 0.000 0.013 0.000 0.000 0.000 0.000 0.013 SSW 0.000 0.000 0.000 0.005 0.017 0.008 0.000 0.000 0.000 0.030 SW 0.000 0.000 0.000 0.003 0.012 0.008 0.000 0.000 0.000 0.023 WSW 0.000 0.000 0.000 0.002 0.008 0.006 0.000 0.000 0.000 0.016 W 0.000 0.000 0.000 0.000 0.009 0.022 0.000 0.000 0.000 0.031 WNW 0.000 0.000 0.000 0.000 0.000 0.024 0.009 0.000 0.000 0.032 NW 0.000 0.000 0.000 0.000 0.002 0.008 0.009 0.000 0.000 0.019 NNW 0.000 0.000 0.000 0.000 0.000 0.015 0.000 0.000 0.000 0.015 SUBTOTAL 0.000 0.000 0.000 0.026 0.104 0.178 0.018 0.000 0.000 0.325 TOTAL HOURS OF VALID OBSERVATIONS 2198.000 TOTAL HOURS OF GROUND LEVEL RELEASE 141.860 TOTAL HOURS OF STABILITY CLASS B 60.680 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS B 7.150 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/10/12 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 103 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.018 0.022 0.000 0.000 0.000 0.040 NNE 0.000 0.000 0.000 0.000 0.022 0.020 0.000 0.000 0.000 0.042 NE 0.000 0.000 0.000 0.000 0.000 0.006 0.000 0.000 0.000 0.006 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.015 0.054 0.000 0.000 0.000 0.000 0.069 SSE 0.000 0.000 0.000 0.005 0.000 0.000 0.000 0.000 0.000 0.005 S 0.000 0.000 0.000 0.009 0.015 0.009 0.000 0.000 0.000 0.032 SSW 0.000 0.000 0.000 0.004 0.029 0.017 0.000 0.000 0.000 0.049 SW 0.000 0.000 0.000 0.009 0.023 0.009 0.000 0.000 0.000 0.041 WSW 0.000 0.000 0.000 0.002 0.006 0.007 0.000 0.000 0.000 0.015 W 0.000 0.000 0.000 0.003 0.015 0.013 0.000 0.000 0.000 0.031 WNW 0.000 0.000 0.000 0.000 0.003 0.023 0.000 0.000 0.000 0.026 NW 0.000 0.000 0.000 0.000 0.014 0.025 0.000 0.000 0.000 0.039 NNW 0.000 0.000 0.000 0.000 0.005 0.015 0.000 0.000 0.000 0.020 SUBTOTAL 0.000 0.000 0.000 0.046 0.203 0.165 0.000 0.000 0.000 0.414 TOTAL HOURS OF VALID OBSERVATIONS 2198.000 TOTAL HOURS OF GROUND LEVEL RELEASE 141.860 TOTAL HOURS OF STABILITY CLASS C 125.560 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS C 9.100 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/10/12 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 104 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.007 0.045 0.088 0.000 0.000 0.000 0.140 NNE 0.000 0.000 0.000 0.019 0.089 0.055 0.000 0.000 0.000 0.162 NE 0.000 0.000 0.000 0.001 0.036 0.037 0.025 0.000 0.000 0.099 ENE 0.000 0.000 0.000 0.001 0.010 0.005 0.000 0.000 0.000 0.017 E 0.000 0.000 0.001 0.016 0.028 0.000 0.000 0.000 0.000 0.045 ESE 0.000 0.000 0.000 0.035 0.065 0.000 0.000 0.000 0.000 0.100 SE 0.000 0.000 0.022 0.128 0.049 0.037 0.000 0.000 0.000 0.235 SSE 0.000 0.000 0.016 0.103 0.000 0.000 0.000 0.000 0.000 0.120 S 0.000 0.000 0.002 0.212 0.240 0.117 0.000 0.000 0.000 0.572 SSW 0.000 0.000 0.000 0.142 0.186 0.171 0.000 0.000 0.000 0.499 SW 0.000 0.000 0.001 0.069 0.025 0.024 0.000 0.000 0.000 0.119 WSW 0.000 0.000 0.000 0.046 0.025 0.027 0.000 0.000 0.000 0.098 W 0.000 0.000 0.000 0.005 0.092 0.027 0.000 0.000 0.000 0.124 WNW 0.000 0.000 0.000 0.003 0.019 0.027 0.000 0.000 0.000 0.049 NW 0.000 0.000 0.000 0.008 0.010 0.015 0.009 0.000 0.000 0.041 NNW 0.000 0.000 0.000 0.007 0.050 0.037 0.000 0.000 0.000 0.094 SUBTOTAL 0.000 0.000 0.043 0.803 0.969 0.667 0.033 0.000 0.000 2.515 TOTAL HOURS OF VALID OBSERVATIONS 2198.000 TOTAL HOURS OF GROUND LEVEL RELEASE 141.860 TOTAL HOURS OF STABILITY CLASS D 1145.940 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS D 55.270 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/10/12 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 105 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.026 0.032 0.015 0.026 0.000 0.000 0.000 0.100 NNE 0.000 0.000 0.013 0.132 0.123 0.044 0.000 0.000 0.000 0.313 NE 0.000 0.000 0.003 0.021 0.065 0.021 0.000 0.000 0.000 0.110 ENE 0.000 0.000 0.010 0.022 0.006 0.000 0.000 0.000 0.000 0.039 E 0.000 0.000 0.015 0.063 0.000 0.000 0.000 0.000 0.000 0.078 ESE 0.000 0.000 0.031 0.124 0.011 0.000 0.000 0.000 0.000 0.166 SE 0.000 0.000 0.020 0.037 0.000 0.000 0.000 0.000 0.000 0.058 SSE 0.000 0.000 0.024 0.025 0.006 0.000 0.000 0.000 0.000 0.056 S 0.000 0.000 0.017 0.079 0.050 0.023 0.000 0.000 0.000 0.169 SSW 0.000 0.000 0.002 0.052 0.054 0.000 0.000 0.000 0.000 0.108 SW 0.000 0.000 0.000 0.006 0.006 0.000 0.000 0.000 0.000 0.012 WSW 0.000 0.000 0.001 0.006 0.000 0.000 0.000 0.000 0.000 0.007 W 0.000 0.000 0.000 0.011 0.003 0.007 0.000 0.000 0.000 0.022 WNW 0.000 0.000 0.000 0.004 0.000 0.013 0.009 0.000 0.000 0.025 NW 0.000 0.000 0.000 0.001 0.008 0.015 0.000 0.000 0.000 0.025 NNW 0.000 0.000 0.011 0.015 0.018 0.000 0.000 0.000 0.000 0.045 SUBTOTAL 0.000 0.000 0.175 0.632 0.366 0.150 0.009 0.000 0.000 1.332 TOTAL HOURS OF VALID OBSERVATIONS 2198.000 TOTAL HOURS OF GROUND LEVEL RELEASE 141.860 TOTAL HOURS OF STABILITY CLASS E 558.800 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS E 29.280 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/10/12 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 106 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.063 0.135 0.007 0.000 0.000 0.000 0.000 0.205 NNE 0.000 0.000 0.014 0.121 0.080 0.000 0.000 0.000 0.000 0.214 NE 0.000 0.000 0.001 0.003 0.006 0.000 0.000 0.000 0.000 0.011 ENE 0.000 0.000 0.004 0.030 0.000 0.000 0.000 0.000 0.000 0.034 E 0.000 0.000 0.019 0.062 0.006 0.000 0.000 0.000 0.000 0.087 ESE 0.000 0.000 0.003 0.030 0.007 0.000 0.000 0.000 0.000 0.040 SE 0.000 0.000 0.000 0.008 0.000 0.000 0.000 0.000 0.000 0.008 SSE 0.000 0.000 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.005 S 0.000 0.000 0.002 0.003 0.007 0.008 0.000 0.000 0.000 0.021 SSW 0.000 0.000 0.001 0.000 0.008 0.000 0.000 0.000 0.000 0.009 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.005 NW 0.000 0.000 0.000 0.001 0.000 0.000 0.000 0.000 0.000 0.001 NNW 0.000 0.000 0.010 0.004 0.025 0.008 0.000 0.000 0.000 0.047 SUBTOTAL 0.000 0.000 0.127 0.398 0.146 0.016 0.000 0.000 0.000 0.687 TOTAL HOURS OF VALID OBSERVATIONS 2198.000 TOTAL HOURS OF GROUND LEVEL RELEASE 141.860 TOTAL HOURS OF STABILITY CLASS F 214.480 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS F 15.110 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/10/12 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 107 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.069 0.098 0.000 0.000 0.000 0.000 0.000 0.167 NNE 0.000 0.000 0.026 0.037 0.051 0.000 0.000 0.000 0.000 0.114 NE 0.000 0.000 0.001 0.005 0.000 0.000 0.000 0.000 0.000 0.005 ENE 0.000 0.000 0.009 0.008 0.000 0.000 0.000 0.000 0.000 0.017 E 0.000 0.000 0.012 0.011 0.001 0.000 0.000 0.000 0.000 0.024 ESE 0.000 0.000 0.004 0.000 0.000 0.000 0.000 0.000 0.000 0.004 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.006 0.000 0.000 0.000 0.006 NNW 0.000 0.000 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.006 SUBTOTAL 0.000 0.000 0.126 0.158 0.052 0.006 0.000 0.000 0.000 0.343 TOTAL HOURS OF VALID OBSERVATIONS 2198.000 TOTAL HOURS OF GROUND LEVEL RELEASE 141.860 TOTAL HOURS OF STABILITY CLASS G 68.760 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS G 7.550 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/10/12 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 108 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.000 0.000 0.000 0.044 0.000 0.037 0.000 0.000 0.081 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.000 0.000 0.042 0.000 0.000 0.000 0.000 0.042 SW 0.000 0.000 0.000 0.000 0.000 0.038 0.000 0.000 0.000 0.038 WSW 0.000 0.000 0.000 0.000 0.000 0.041 0.000 0.000 0.000 0.041 W 0.000 0.000 0.000 0.000 0.042 0.000 0.000 0.000 0.000 0.042 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.000 0.128 0.080 0.037 0.000 0.000 0.245 TOTAL HOURS OF VALID OBSERVATIONS 2198.000 TOTAL HOURS OF ELEVATED RELEASES 2056.140 TOTAL HOURS OF STABILITY CLASS A 23.780 TOTAL HOURS OF ELEVATED STABILITY CLASS A 5.380 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/10/12 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 109 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.222 0.000 0.000 0.222 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.000 0.000 0.000 0.042 0.080 0.000 0.000 0.000 0.122 S 0.000 0.000 0.000 0.000 0.043 0.081 0.000 0.000 0.000 0.123 SSW 0.000 0.000 0.045 0.091 0.087 0.315 0.075 0.000 0.000 0.614 SW 0.000 0.000 0.000 0.045 0.086 0.202 0.000 0.000 0.000 0.334 WSW 0.000 0.000 0.000 0.136 0.088 0.079 0.075 0.000 0.000 0.378 W 0.000 0.000 0.000 0.136 0.219 0.159 0.000 0.000 0.000 0.515 WNW 0.000 0.000 0.000 0.000 0.086 0.041 0.000 0.000 0.000 0.127 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.045 0.409 0.652 0.958 0.371 0.000 0.000 2.435 TOTAL HOURS OF VALID OBSERVATIONS 2198.000 TOTAL HOURS OF ELEVATED RELEASES 2056.140 TOTAL HOURS OF STABILITY CLASS B 60.680 TOTAL HOURS OF ELEVATED STABILITY CLASS B 53.530 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/10/12 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 110 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.043 0.159 0.110 0.000 0.000 0.312 NNE 0.000 0.000 0.000 0.000 0.000 0.080 0.186 0.000 0.000 0.266 NE 0.000 0.000 0.000 0.000 0.000 0.038 0.038 0.000 0.000 0.076 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.044 0.041 0.000 0.000 0.000 0.086 SSE 0.000 0.000 0.000 0.136 0.175 0.081 0.000 0.000 0.000 0.393 S 0.000 0.000 0.000 0.045 0.000 0.284 0.000 0.000 0.000 0.329 SSW 0.000 0.000 0.045 0.227 0.174 0.357 0.075 0.000 0.000 0.879 SW 0.000 0.000 0.000 0.273 0.433 0.242 0.112 0.000 0.000 1.060 WSW 0.000 0.000 0.000 0.273 0.221 0.081 0.000 0.000 0.000 0.575 W 0.000 0.000 0.000 0.182 0.308 0.160 0.000 0.000 0.000 0.650 WNW 0.000 0.000 0.000 0.045 0.000 0.162 0.037 0.000 0.000 0.245 NW 0.000 0.000 0.000 0.000 0.088 0.000 0.074 0.000 0.000 0.162 NNW 0.000 0.000 0.000 0.000 0.000 0.156 0.111 0.000 0.000 0.267 SUBTOTAL 0.000 0.000 0.045 1.183 1.486 1.841 0.742 0.000 0.000 5.298 TOTAL HOURS OF VALID OBSERVATIONS 2198.000 TOTAL HOURS OF ELEVATED RELEASES 2056.140 TOTAL HOURS OF STABILITY CLASS C 125.560 TOTAL HOURS OF ELEVATED STABILITY CLASS C 116.460 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/10/12 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 111 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data P
ART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.091 0.136 0.219 1.003 0.408 0.000 0.000 1.858 NNE 0.000 0.045 0.182 0.227 0.430 1.129 0.148 0.000 0.000 2.162 NE 0.000 0.045 0.045 0.273 0.087 0.281 0.000 0.030 0.000 0.762 ENE 0.000 0.000 0.182 0.273 0.089 0.122 0.000 0.000 0.000 0.666 E 0.000 0.000 0.136 0.136 0.129 0.247 0.000 0.000 0.000 0.648 ESE 0.000 0.000 0.227 0.409 0.659 1.076 0.113 0.000 0.000 2.485 SE 0.000 0.000 0.455 1.865 1.103 1.682 0.298 0.028 0.000 5.432 SSE 0.000 0.000 0.591 1.774 1.271 1.496 0.223 0.000 0.000 5.356 S 0.000 0.000 0.591 1.683 2.186 2.835 0.554 0.000 0.000 7.849 SSW 0.000 0.000 0.773 1.865 1.758 2.487 0.672 0.000 0.000 7.555 SW 0.000 0.000 0.728 2.275 1.369 1.419 0.261 0.000 0.000 6.051 WSW 0.000 0.000 0.273 1.729 1.449 0.402 0.038 0.000 0.000 3.891 W 0.000 0.000 0.091 0.409 0.561 0.937 0.075 0.000 0.000 2.073 WNW 0.000 0.000 0.045 0.227 0.130 0.405 0.074 0.000 0.000 0.882 NW 0.000 0.000 0.000 0.045 0.259 0.364 0.111 0.000 0.000 0.780 NNW 0.000 0.045 0.045 0.227 0.219 0.482 0.150 0.000 0.000 1.170 SUBTOTAL 0.000 0.136 4.459 13.558 11.919 16.366 3.125 0.058 0.000 49.621 TOTAL HOURS OF VALID OBSERVATIONS 2198.000 TOTAL HOURS OF ELEVATED RELEASES 2056.140 TOTAL HOURS OF STABILITY CLASS D 1145.940 TOTAL HOURS OF ELEVATED STABILITY CLASS D 1090.670 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/10/12 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 112 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.318 0.273 0.610 1.005 0.186 0.000 0.000 2.391 NNE 0.000 0.000 0.045 0.364 0.441 1.223 0.489 0.000 0.000 2.562 NE 0.000 0.000 0.182 0.227 0.090 0.556 0.038 0.000 0.000 1.093 ENE 0.000 0.045 0.091 0.273 0.305 0.121 0.000 0.000 0.000 0.835 E 0.000 0.000 0.091 0.136 0.483 0.205 0.000 0.000 0.000 0.915 ESE 0.000 0.000 0.227 0.227 0.565 1.091 0.000 0.000 0.000 2.111 SE 0.000 0.000 0.364 0.409 1.146 0.686 0.037 0.034 0.000 2.676 SSE 0.000 0.000 0.500 0.773 0.351 0.446 0.038 0.000 0.000 2.109 S 0.000 0.000 0.273 0.546 0.486 0.788 0.263 0.000 0.000 2.357 SSW 0.000 0.045 0.318 0.728 0.260 0.728 0.038 0.000 0.000 2.117 SW 0.000 0.000 0.455 0.364 0.400 0.200 0.000 0.000 0.000 1.419 WSW 0.000 0.000 0.136 0.364 0.223 0.120 0.000 0.000 0.000 0.843 W 0.000 0.000 0.091 0.318 0.348 0.280 0.036 0.000 0.000 1.074 WNW 0.000 0.000 0.091 0.091 0.176 0.042 0.000 0.000 0.000 0.400 NW 0.000 0.000 0.182 0.045 0.000 0.201 0.075 0.000 0.000 0.503 NNW 0.000 0.000 0.045 0.182 0.261 0.197 0.000 0.000 0.000 0.685 SUBTOTAL 0.000 0.091 3.412 5.323 6.144 7.888 1.199 0.034 0.000 24.091 TOTAL HOURS OF VALID OBSERVATIONS 2198.000 TOTAL HOURS OF ELEVATED RELEASES 2056.140 TOTAL HOURS OF STABILITY CLASS E 558.800 TOTAL HOURS OF ELEVATED STABILITY CLASS E 529.520 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/10/12 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 113 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.133 0.675 0.113 0.000 0.000 0.921 NNE 0.000 0.000 0.045 0.000 0.129 0.831 0.151 0.000 0.000 1.157 NE 0.000 0.000 0.000 0.227 0.305 0.488 0.000 0.000 0.000 1.021 ENE 0.000 0.000 0.136 0.136 0.000 0.163 0.000 0.000 0.000 0.436 E 0.000 0.000 0.136 0.182 0.306 0.162 0.000 0.000 0.000 0.787 ESE 0.000 0.000 0.045 0.318 0.520 0.328 0.000 0.000 0.000 1.212 SE 0.000 0.000 0.182 0.182 0.356 0.167 0.000 0.000 0.000 0.887 SSE 0.000 0.000 0.000 0.091 0.089 0.000 0.000 0.000 0.000 0.180 S 0.000 0.000 0.045 0.091 0.089 0.038 0.075 0.000 0.000 0.339 SSW 0.000 0.000 0.091 0.136 0.044 0.041 0.000 0.000 0.000 0.313 SW 0.000 0.000 0.182 0.000 0.045 0.000 0.000 0.000 0.000 0.227 WSW 0.000 0.000 0.045 0.136 0.043 0.000 0.000 0.000 0.000 0.225 W 0.000 0.045 0.000 0.227 0.091 0.000 0.000 0.000 0.000 0.364 WNW 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.091 NW 0.000 0.000 0.045 0.091 0.088 0.039 0.000 0.000 0.000 0.263 NNW 0.000 0.000 0.000 0.045 0.132 0.322 0.149 0.000 0.000 0.649 SUBTOTAL 0.000 0.045 0.955 1.956 2.371 3.253 0.489 0.000 0.000 9.071 TOTAL HOURS OF VALID OBSERVATIONS 2198.000 TOTAL HOURS OF ELEVATED RELEASES 2056.140 TOTAL HOURS OF STABILITY CLASS F 214.480 TOTAL HOURS OF ELEVATED STABILITY CLASS F 199.370 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/10/12 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 114 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.045 0.043 0.202 0.038 0.000 0.000 0.328 NNE 0.000 0.000 0.000 0.000 0.044 0.244 0.446 0.000 0.000 0.734 NE 0.000 0.000 0.045 0.136 0.043 0.328 0.000 0.000 0.000 0.552 ENE 0.000 0.045 0.000 0.091 0.043 0.000 0.000 0.000 0.000 0.179 E 0.000 0.000 0.045 0.000 0.042 0.000 0.000 0.000 0.000 0.088 ESE 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.045 SE 0.000 0.000 0.000 0.227 0.000 0.000 0.000 0.000 0.000 0.227 SSE 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.045 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.045 0.045 0.000 0.000 0.000 0.000 0.000 0.091 SW 0.000 0.000 0.136 0.000 0.000 0.000 0.000 0.000 0.000 0.136 WSW 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.045 W 0.000 0.045 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.091 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.045 0.045 0.000 0.000 0.000 0.000 0.000 0.091 NNW 0.000 0.000 0.045 0.045 0.000 0.040 0.000 0.000 0.000 0.131 SUBTOTAL 0.000 0.091 0.364 0.819 0.214 0.813 0.484 0.000 0.000 2.785 TOTAL HOURS OF VALID OBSERVATIONS 2198.000 TOTAL HOURS OF ELEVATED RELEASES 2056.140 TOTAL HOURS OF STABILITY CLASS G 68.760 TOTAL HOURS OF ELEVATED STABILITY CLASS G 61.210 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2022/10/12 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 115 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data Table 7-D Split Level Releases - 4th Quarter JFD Joint Frequency Distribution In Percent (Ground Level Release Mode And Elevated Release Mode)
Page 116 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.038 0.000 0.000 0.000 0.038 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.005 0.000 0.000 0.000 0.000 0.005 SE 0.000 0.000 0.000 0.003 0.049 0.015 0.000 0.000 0.000 0.068 SSE 0.000 0.000 0.000 0.012 0.010 0.000 0.000 0.000 0.000 0.021 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.001 0.012 0.000 0.000 0.000 0.000 0.014 W 0.000 0.000 0.000 0.000 0.000 0.024 0.012 0.000 0.000 0.035 WNW 0.000 0.000 0.000 0.000 0.000 0.008 0.018 0.000 0.000 0.026 NW 0.000 0.000 0.000 0.000 0.000 0.024 0.009 0.000 0.000 0.033 NNW 0.000 0.000 0.000 0.000 0.000 0.071 0.009 0.000 0.000 0.080 SUBTOTAL 0.000 0.000 0.000 0.017 0.076 0.180 0.047 0.000 0.000 0.320 TOTAL HOURS OF VALID OBSERVATIONS 2200.000 TOTAL HOURS OF GROUND LEVEL RELEASE 273.180 TOTAL HOURS OF STABILITY CLASS A 7.040 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS A 7.040 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2023/01/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 117 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.007 0.055 0.000 0.000 0.000 0.062 NNE 0.000 0.000 0.000 0.000 0.000 0.018 0.000 0.000 0.000 0.018 NE 0.000 0.000 0.000 0.000 0.003 0.000 0.000 0.000 0.000 0.003 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.007 0.020 0.061 0.000 0.000 0.000 0.088 SSE 0.000 0.000 0.000 0.009 0.014 0.009 0.000 0.000 0.000 0.032 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.001 0.000 0.009 0.000 0.000 0.000 0.010 WSW 0.000 0.000 0.000 0.000 0.006 0.031 0.000 0.000 0.000 0.037 W 0.000 0.000 0.000 0.000 0.025 0.061 0.009 0.000 0.000 0.095 WNW 0.000 0.000 0.000 0.000 0.011 0.060 0.065 0.000 0.000 0.136 NW 0.000 0.000 0.000 0.000 0.008 0.054 0.014 0.000 0.000 0.075 NNW 0.000 0.000 0.000 0.000 0.004 0.021 0.009 0.000 0.000 0.034 SUBTOTAL 0.000 0.000 0.000 0.017 0.098 0.378 0.097 0.000 0.000 0.590 TOTAL HOURS OF VALID OBSERVATIONS 2200.000 TOTAL HOURS OF GROUND LEVEL RELEASE 273.180 TOTAL HOURS OF STABILITY CLASS B 21.570 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS B 12.980 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2023/01/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 118 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.023 0.000 0.000 0.000 0.023 NNE 0.000 0.000 0.000 0.000 0.013 0.032 0.000 0.000 0.000 0.045 NE 0.000 0.000 0.000 0.000 0.000 0.011 0.000 0.000 0.000 0.011 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.008 0.060 0.066 0.000 0.000 0.000 0.134 SSE 0.000 0.000 0.000 0.011 0.016 0.000 0.000 0.000 0.000 0.027 S 0.000 0.000 0.000 0.001 0.022 0.000 0.000 0.000 0.000 0.023 SSW 0.000 0.000 0.000 0.008 0.000 0.000 0.000 0.000 0.000 0.008 SW 0.000 0.000 0.000 0.000 0.006 0.016 0.000 0.000 0.000 0.023 WSW 0.000 0.000 0.000 0.001 0.000 0.014 0.000 0.000 0.000 0.015 W 0.000 0.000 0.000 0.001 0.005 0.033 0.009 0.000 0.000 0.048 WNW 0.000 0.000 0.000 0.000 0.011 0.049 0.020 0.000 0.000 0.081 NW 0.000 0.000 0.000 0.000 0.013 0.039 0.027 0.000 0.000 0.079 NNW 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.091 SUBTOTAL 0.000 0.000 0.000 0.031 0.147 0.375 0.056 0.000 0.000 0.609 TOTAL HOURS OF VALID OBSERVATIONS 2200.000 TOTAL HOURS OF GROUND LEVEL RELEASE 273.180 TOTAL HOURS OF STABILITY CLASS C 74.790 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS C 13.390 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2023/01/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 119 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.015 0.043 0.056 0.000 0.000 0.000 0.113 NNE 0.000 0.000 0.004 0.026 0.101 0.030 0.000 0.000 0.000 0.161 NE 0.000 0.000 0.000 0.016 0.057 0.040 0.000 0.000 0.000 0.113 ENE 0.000 0.000 0.000 0.002 0.010 0.005 0.000 0.000 0.000 0.019 E 0.000 0.000 0.000 0.001 0.005 0.000 0.000 0.000 0.000 0.006 ESE 0.000 0.000 0.000 0.050 0.095 0.023 0.000 0.000 0.000 0.169 SE 0.000 0.000 0.000 0.092 0.164 0.925 0.167 0.000 0.000 1.348 SSE 0.000 0.000 0.006 0.049 0.125 0.163 0.000 0.000 0.000 0.343 S 0.000 0.000 0.001 0.011 0.050 0.167 0.022 0.000 0.000 0.251 SSW 0.000 0.000 0.005 0.016 0.006 0.039 0.000 0.000 0.000 0.067 SW 0.000 0.000 0.004 0.015 0.045 0.059 0.030 0.000 0.000 0.152 WSW 0.000 0.000 0.000 0.050 0.045 0.057 0.000 0.000 0.000 0.151 W 0.000 0.000 0.000 0.025 0.103 0.245 0.059 0.000 0.000 0.432 WNW 0.000 0.000 0.000 0.002 0.029 0.136 0.135 0.045 0.000 0.346 NW 0.000 0.000 0.000 0.003 0.066 0.255 0.170 0.252 0.045 0.792 NNW 0.000 0.000 0.000 0.021 0.083 0.328 0.009 0.000 0.000 0.441 SUBTOTAL 0.000 0.000 0.021 0.395 1.026 2.528 0.591 0.297 0.045 4.904 TOTAL HOURS OF VALID OBSERVATIONS 2200.000 TOTAL HOURS OF GROUND LEVEL RELEASE 273.180 TOTAL HOURS OF STABILITY CLASS D 891.610 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS D 107.880 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2023/01/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 120 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.033 0.073 0.045 0.000 0.000 0.000 0.000 0.151 NNE 0.000 0.000 0.011 0.158 0.058 0.008 0.013 0.000 0.000 0.249 NE 0.000 0.000 0.011 0.055 0.046 0.000 0.000 0.000 0.000 0.112 ENE 0.000 0.000 0.014 0.024 0.015 0.000 0.000 0.000 0.000 0.053 E 0.000 0.000 0.029 0.086 0.014 0.015 0.000 0.000 0.000 0.144 ESE 0.000 0.000 0.040 0.198 0.115 0.025 0.000 0.000 0.000 0.378 SE 0.000 0.000 0.036 0.173 0.065 0.165 0.000 0.000 0.000 0.439 SSE 0.000 0.000 0.010 0.079 0.140 0.409 0.227 0.000 0.000 0.865 S 0.000 0.000 0.005 0.025 0.074 0.286 0.159 0.000 0.000 0.549 SSW 0.000 0.000 0.003 0.002 0.026 0.105 0.021 0.000 0.000 0.157 SW 0.000 0.000 0.001 0.016 0.017 0.043 0.000 0.000 0.000 0.077 WSW 0.000 0.000 0.000 0.005 0.018 0.000 0.000 0.000 0.000 0.023 W 0.000 0.000 0.001 0.029 0.026 0.008 0.000 0.000 0.000 0.065 WNW 0.000 0.000 0.000 0.008 0.018 0.014 0.000 0.000 0.000 0.040 NW 0.000 0.000 0.004 0.048 0.029 0.046 0.000 0.000 0.000 0.127 NNW 0.000 0.000 0.013 0.055 0.184 0.095 0.000 0.000 0.000 0.346 SUBTOTAL 0.000 0.000 0.213 1.032 0.890 1.219 0.420 0.000 0.000 3.774 TOTAL HOURS OF VALID OBSERVATIONS 2200.000 TOTAL HOURS OF GROUND LEVEL RELEASE 273.180 TOTAL HOURS OF STABILITY CLASS E 793.630 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS E 83.030 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2023/01/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 121 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.026 0.122 0.000 0.000 0.000 0.000 0.000 0.148 NNE 0.000 0.000 0.013 0.102 0.020 0.000 0.000 0.000 0.000 0.135 NE 0.000 0.000 0.002 0.013 0.007 0.000 0.000 0.000 0.000 0.023 ENE 0.000 0.000 0.007 0.016 0.000 0.000 0.000 0.000 0.000 0.024 E 0.000 0.000 0.034 0.037 0.000 0.000 0.000 0.000 0.000 0.070 ESE 0.000 0.000 0.046 0.091 0.021 0.000 0.000 0.000 0.000 0.159 SE 0.000 0.000 0.032 0.083 0.085 0.065 0.000 0.000 0.000 0.265 SSE 0.000 0.000 0.024 0.103 0.083 0.205 0.091 0.000 0.000 0.505 S 0.000 0.000 0.005 0.012 0.029 0.044 0.000 0.000 0.000 0.089 SSW 0.000 0.000 0.004 0.018 0.000 0.000 0.000 0.000 0.000 0.022 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.004 0.005 0.000 0.000 0.000 0.000 0.000 0.010 NNW 0.000 0.000 0.014 0.055 0.015 0.000 0.000 0.000 0.000 0.083 SUBTOTAL 0.000 0.000 0.211 0.657 0.260 0.314 0.091 0.000 0.000 1.532 TOTAL HOURS OF VALID OBSERVATIONS 2200.000 TOTAL HOURS OF GROUND LEVEL RELEASE 273.180 TOTAL HOURS OF STABILITY CLASS F 295.460 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS F 33.710 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2023/01/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 122 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.032 0.149 0.028 0.000 0.000 0.000 0.000 0.209 NNE 0.000 0.000 0.008 0.074 0.007 0.000 0.000 0.000 0.000 0.089 NE 0.000 0.000 0.006 0.021 0.000 0.000 0.000 0.000 0.000 0.027 ENE 0.000 0.000 0.017 0.027 0.000 0.000 0.000 0.000 0.000 0.044 E 0.000 0.000 0.022 0.003 0.000 0.000 0.000 0.000 0.000 0.025 ESE 0.000 0.000 0.000 0.011 0.000 0.000 0.000 0.000 0.000 0.011 SE 0.000 0.000 0.036 0.015 0.047 0.016 0.000 0.000 0.000 0.115 SSE 0.000 0.000 0.031 0.025 0.017 0.075 0.000 0.000 0.000 0.148 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.001 NNW 0.000 0.000 0.013 0.008 0.000 0.000 0.000 0.000 0.000 0.020 SUBTOTAL 0.000 0.000 0.165 0.333 0.100 0.091 0.000 0.000 0.000 0.689 TOTAL HOURS OF VALID OBSERVATIONS 2200.000 TOTAL HOURS OF GROUND LEVEL RELEASE 273.180 TOTAL HOURS OF STABILITY CLASS G 115.900 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS G 15.150 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2023/01/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 123 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL HOURS OF VALID OBSERVATIONS 2200.000 TOTAL HOURS OF ELEVATED RELEASES 1926.820 TOTAL HOURS OF STABILITY CLASS A 7.040 TOTAL HOURS OF ELEVATED STABILITY CLASS A 0.000 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2023/01/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 124 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.078 0.000 0.000 0.000 0.078 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.045 0.045 0.000 0.000 0.000 0.000 0.091 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.034 0.000 0.034 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.037 0.000 0.000 0.037 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.077 0.075 0.000 0.000 0.151 SUBTOTAL 0.000 0.000 0.000 0.045 0.045 0.155 0.111 0.034 0.000 0.390 TOTAL HOURS OF VALID OBSERVATIONS 2200.000 TOTAL HOURS OF ELEVATED RELEASES 1926.820 TOTAL HOURS OF STABILITY CLASS B 21.570 TOTAL HOURS OF ELEVATED STABILITY CLASS B 8.590 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2023/01/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 125 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.043 0.392 0.111 0.000 0.000 0.545 NNE 0.000 0.000 0.000 0.000 0.000 0.079 0.000 0.000 0.000 0.079 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.040 0.000 0.000 0.000 0.040 SE 0.000 0.000 0.000 0.000 0.044 0.039 0.000 0.000 0.000 0.082 SSE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.091 0.136 0.000 0.000 0.000 0.000 0.000 0.227 SW 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.045 WSW 0.000 0.000 0.000 0.000 0.085 0.240 0.000 0.000 0.000 0.325 W 0.000 0.000 0.000 0.045 0.088 0.240 0.335 0.000 0.000 0.708 WNW 0.000 0.000 0.000 0.000 0.000 0.039 0.260 0.024 0.000 0.323 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.075 0.000 0.000 0.075 NNW 0.000 0.000 0.000 0.000 0.000 0.119 0.222 0.000 0.000 0.341 SUBTOTAL 0.000 0.000 0.091 0.227 0.259 1.187 1.003 0.024 0.000 2.791 TOTAL HOURS OF VALID OBSERVATIONS 2200.000 TOTAL HOURS OF ELEVATED RELEASES 1926.820 TOTAL HOURS OF STABILITY CLASS C 74.790 TOTAL HOURS OF ELEVATED STABILITY CLASS C 61.400 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2023/01/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 126 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.273 0.091 0.128 0.512 0.261 0.035 0.000 1.299 NNE 0.000 0.000 0.136 0.182 0.608 1.318 0.150 0.000 0.000 2.395 NE 0.000 0.000 0.091 0.273 0.305 0.446 0.000 0.000 0.000 1.115 ENE 0.000 0.000 0.000 0.455 0.221 0.040 0.000 0.000 0.000 0.715 E 0.000 0.000 0.045 0.409 0.135 0.157 0.000 0.000 0.000 0.747 ESE 0.000 0.000 0.091 0.227 0.527 1.801 0.555 0.023 0.004 3.230 SE 0.000 0.045 0.136 0.136 0.565 1.229 1.027 0.744 0.053 3.936 SSE 0.000 0.000 0.273 0.136 0.174 0.522 0.924 0.108 0.000 2.137 S 0.000 0.000 0.182 0.409 0.225 0.318 0.372 0.135 0.000 1.641 SSW 0.000 0.000 0.318 0.136 0.087 0.314 0.150 0.000 0.000 1.005 SW 0.000 0.045 0.000 0.091 0.350 0.557 0.293 0.035 0.000 1.370 WSW 0.000 0.000 0.227 0.318 0.567 1.201 0.264 0.000 0.000 2.578 W 0.000 0.045 0.136 0.273 0.606 2.068 0.668 0.106 0.000 3.903 WNW 0.000 0.000 0.045 0.182 0.395 1.873 0.480 0.283 0.001 3.259 NW 0.000 0.000 0.091 0.182 0.219 1.545 1.152 0.143 0.020 3.352 NNW 0.000 0.000 0.091 0.227 0.257 1.546 0.821 0.000 0.000 2.942 SUBTOTAL 0.000 0.136 2.136 3.727 5.370 15.447 7.118 1.611 0.078 35.624 TOTAL HOURS OF VALID OBSERVATIONS 2200.000 TOTAL HOURS OF ELEVATED RELEASES 1926.820 TOTAL HOURS OF STABILITY CLASS D 891.610 TOTAL HOURS OF ELEVATED STABILITY CLASS D 783.730 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2023/01/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 127 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.318 0.698 0.904 0.149 0.000 0.000 2.069 NNE 0.000 0.045 0.182 0.273 0.701 1.600 0.075 0.032 0.000 2.908 NE 0.000 0.000 0.182 0.455 0.434 0.808 0.000 0.000 0.000 1.878 ENE 0.000 0.000 0.182 0.409 0.395 0.160 0.000 0.000 0.000 1.146 E 0.000 0.000 0.136 0.591 0.390 0.733 0.038 0.000 0.000 1.888 ESE 0.000 0.000 0.227 0.455 0.657 1.753 0.299 0.036 0.004 3.431 SE 0.000 0.000 0.091 0.045 0.396 1.910 1.110 0.316 0.008 3.876 SSE 0.000 0.000 0.045 0.182 0.265 0.639 1.135 0.643 0.020 2.929 S 0.000 0.000 0.182 0.455 0.308 0.715 0.849 0.124 0.000 2.632 SSW 0.000 0.000 0.364 0.273 0.268 0.552 0.520 0.025 0.000 2.001 SW 0.000 0.045 0.136 0.409 0.485 0.282 0.073 0.057 0.000 1.488 WSW 0.000 0.000 0.045 0.318 0.130 0.157 0.000 0.000 0.000 0.650 W 0.000 0.000 0.136 0.318 0.310 0.286 0.037 0.000 0.000 1.088 WNW 0.000 0.000 0.045 0.045 0.132 0.200 0.000 0.000 0.000 0.423 NW 0.000 0.000 0.091 0.182 0.173 0.952 0.448 0.000 0.000 1.846 NNW 0.000 0.000 0.000 0.273 0.563 0.874 0.338 0.000 0.000 2.047 SUBTOTAL 0.000 0.091 2.045 5.000 6.305 12.524 5.071 1.232 0.031 32.300 TOTAL HOURS OF VALID OBSERVATIONS 2200.000 TOTAL HOURS OF ELEVATED RELEASES 1926.820 TOTAL HOURS OF STABILITY CLASS E 793.630 TOTAL HOURS OF ELEVATED STABILITY CLASS E 710.600 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2023/01/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 128 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.045 0.045 0.630 0.000 0.000 0.000 0.721 NNE 0.000 0.000 0.182 0.045 0.088 0.836 0.000 0.000 0.000 1.151 NE 0.000 0.000 0.045 0.227 0.088 0.672 0.000 0.000 0.000 1.033 ENE 0.000 0.000 0.045 0.091 0.175 0.365 0.000 0.000 0.000 0.676 E 0.000 0.045 0.182 0.091 0.213 0.397 0.000 0.000 0.000 0.928 ESE 0.000 0.000 0.045 0.273 0.173 0.847 0.000 0.000 0.000 1.338 SE 0.000 0.000 0.091 0.136 0.217 0.910 0.183 0.115 0.000 1.652 SSE 0.000 0.000 0.000 0.045 0.088 0.434 0.592 0.089 0.000 1.249 S 0.000 0.000 0.045 0.136 0.000 0.078 0.037 0.000 0.000 0.297 SSW 0.000 0.000 0.091 0.182 0.042 0.000 0.000 0.000 0.000 0.315 SW 0.000 0.000 0.136 0.182 0.000 0.000 0.000 0.000 0.000 0.318 WSW 0.000 0.000 0.136 0.227 0.000 0.000 0.000 0.000 0.000 0.364 W 0.000 0.000 0.136 0.227 0.044 0.000 0.000 0.000 0.000 0.408 WNW 0.000 0.000 0.227 0.227 0.000 0.000 0.000 0.000 0.000 0.455 NW 0.000 0.000 0.000 0.227 0.043 0.160 0.000 0.000 0.000 0.430 NNW 0.000 0.000 0.000 0.045 0.000 0.518 0.000 0.000 0.000 0.563 SUBTOTAL 0.000 0.045 1.364 2.409 1.217 5.845 0.813 0.204 0.000 11.898 TOTAL HOURS OF VALID OBSERVATIONS 2200.000 TOTAL HOURS OF ELEVATED RELEASES 1926.820 TOTAL HOURS OF STABILITY CLASS F 295.460 TOTAL HOURS OF ELEVATED STABILITY CLASS F 261.750 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2023/01/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 129 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.045 0.091 0.000 0.079 0.000 0.000 0.000 0.215 NNE 0.000 0.000 0.091 0.091 0.044 0.426 0.151 0.000 0.000 0.802 NE 0.000 0.000 0.091 0.091 0.264 0.316 0.000 0.000 0.000 0.762 ENE 0.000 0.000 0.136 0.045 0.045 0.000 0.000 0.000 0.000 0.227 E 0.000 0.000 0.182 0.273 0.130 0.124 0.000 0.000 0.000 0.709 ESE 0.000 0.000 0.182 0.091 0.128 0.042 0.000 0.000 0.000 0.443 SE 0.000 0.000 0.000 0.000 0.173 0.080 0.000 0.000 0.000 0.253 SSE 0.000 0.045 0.091 0.045 0.089 0.080 0.000 0.000 0.000 0.351 S 0.000 0.000 0.136 0.000 0.000 0.000 0.000 0.000 0.000 0.136 SSW 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.091 SW 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.091 WSW 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.045 W 0.000 0.045 0.000 0.091 0.045 0.000 0.000 0.000 0.000 0.181 WNW 0.000 0.000 0.000 0.136 0.000 0.000 0.000 0.000 0.000 0.136 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.136 0.000 0.000 0.000 0.000 0.000 0.000 0.136 SUBTOTAL 0.000 0.091 1.227 1.045 0.919 1.146 0.151 0.000 0.000 4.580 TOTAL HOURS OF VALID OBSERVATIONS 2200.000 TOTAL HOURS OF ELEVATED RELEASES 1926.820 TOTAL HOURS OF STABILITY CLASS G 115.900 TOTAL HOURS OF ELEVATED STABILITY CLASS G 100.750 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2023/01/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 130 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data Table 8-A Elevated Releases - 1st Quarter JFD Joint Frequency Distribution In Percent Page 131 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2151 TOTAL HOURS OF STABILITY CLASS A 0 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A 0 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2151 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2022/04/07 MEAN WIND SPEED = 0.00 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 132 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 SSE 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 S 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.046 0.139 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2151 TOTAL HOURS OF STABILITY CLASS B 3 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B 3 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2151 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2022/04/07 MEAN WIND SPEED = 16.67 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 133 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.093 0.186 0.000 0.000 0.279 NNE 0.000 0.000 0.000 0.000 0.000 0.093 0.093 0.000 0.000 0.186 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.093 SE 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 SSE 0.000 0.000 0.000 0.000 0.000 0.000 0.186 0.000 0.000 0.186 S 0.000 0.000 0.000 0.000 0.000 0.139 0.046 0.000 0.000 0.186 SSW 0.000 0.000 0.000 0.000 0.000 0.139 0.000 0.000 0.000 0.139 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.139 0.000 0.046 0.000 0.186 W 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.093 0.000 0.139 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.093 0.139 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.000 0.046 0.697 0.558 0.186 0.093 1.581 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2151 TOTAL HOURS OF STABILITY CLASS C 34 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 34 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2151 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2022/04/07 MEAN WIND SPEED = 14.04 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 134 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.046 0.232 0.511 2.139 2.650 0.930 0.139 6.648 NNE 0.000 0.000 0.000 0.325 0.651 2.046 1.488 0.186 0.046 4.742 NE 0.000 0.000 0.046 0.046 0.558 0.790 0.232 0.000 0.000 1.674 ENE 0.000 0.000 0.093 0.046 0.093 0.279 0.139 0.000 0.000 0.651 E 0.000 0.000 0.000 0.046 0.093 0.372 0.511 0.093 0.000 1.116 ESE 0.000 0.000 0.000 0.325 0.232 0.558 0.604 0.139 0.046 1.906 SE 0.000 0.000 0.186 0.186 0.232 0.279 0.279 0.186 0.093 1.441 SSE 0.000 0.000 0.139 0.046 0.139 0.465 0.465 0.558 0.093 1.906 S 0.000 0.000 0.046 0.093 0.139 0.651 0.744 0.046 0.000 1.720 SSW 0.000 0.046 0.279 0.139 0.186 0.418 0.325 0.186 0.046 1.627 SW 0.000 0.000 0.093 0.139 0.046 0.418 0.558 0.232 0.000 1.488 WSW 0.000 0.000 0.093 0.093 0.093 0.651 0.604 0.186 0.000 1.720 W 0.000 0.000 0.325 0.697 0.976 0.651 1.348 0.744 0.000 4.742 WNW 0.000 0.000 0.186 0.558 0.837 1.255 1.069 0.744 0.418 5.067 NW 0.000 0.000 0.093 0.325 0.232 0.651 1.953 1.162 0.372 4.788 NNW 0.000 0.000 0.046 0.139 0.139 1.720 2.882 1.209 0.232 6.369 SUBTOTAL 0.000 0.046 1.674 3.440 5.160 13.343 15.853 6.602 1.488 47.606 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2151 TOTAL HOURS OF STABILITY CLASS D 1024 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D 1024 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2151 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2022/04/07 MEAN WIND SPEED = 12.76 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 135 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.186 0.046 1.302 1.069 0.093 0.000 2.696 NNE 0.000 0.000 0.000 0.139 0.000 0.790 1.209 0.046 0.000 2.185 NE 0.000 0.000 0.000 0.000 0.093 0.697 0.604 0.000 0.000 1.395 ENE 0.000 0.000 0.046 0.093 0.232 0.651 0.837 0.046 0.000 1.906 E 0.000 0.046 0.139 0.093 0.139 0.232 0.325 0.093 0.000 1.069 ESE 0.000 0.000 0.046 0.139 0.186 0.558 0.511 0.093 0.000 1.534 SE 0.000 0.000 0.093 0.139 0.093 0.744 0.930 1.069 0.883 3.952 SSE 0.000 0.000 0.046 0.093 0.046 1.023 1.534 2.046 1.023 5.811 S 0.000 0.000 0.000 0.046 0.232 0.558 1.813 1.906 1.395 5.951 SSW 0.000 0.000 0.000 0.232 0.186 0.651 0.744 0.465 0.418 2.696 SW 0.000 0.000 0.046 0.093 0.093 0.744 0.325 0.093 0.000 1.395 WSW 0.000 0.046 0.093 0.093 0.139 0.418 0.186 0.046 0.000 1.023 W 0.000 0.000 0.139 0.186 0.232 0.651 0.186 0.046 0.000 1.441 WNW 0.000 0.046 0.000 0.186 0.186 0.697 0.279 0.000 0.046 1.441 NW 0.000 0.000 0.139 0.046 0.046 0.232 0.604 0.000 0.000 1.069 NNW 0.000 0.000 0.046 0.093 0.046 0.465 0.790 0.000 0.000 1.441 SUBTOTAL 0.000 0.139 0.837 1.860 1.999 10.414 11.948 6.044 3.766 37.006 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2151 TOTAL HOURS OF STABILITY CLASS E 796 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E 796 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2151 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2022/04/07 MEAN WIND SPEED = 14.74 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 136 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.046 0.000 0.000 0.093 0.093 0.372 0.000 0.000 0.604 NNE 0.000 0.000 0.046 0.046 0.046 0.000 0.093 0.000 0.000 0.232 NE 0.000 0.000 0.000 0.139 0.000 0.000 0.093 0.000 0.000 0.232 ENE 0.000 0.000 0.000 0.000 0.046 0.139 0.046 0.000 0.000 0.232 E 0.000 0.000 0.000 0.046 0.093 0.093 0.186 0.000 0.000 0.418 ESE 0.000 0.000 0.000 0.046 0.000 0.232 0.093 0.000 0.000 0.372 SE 0.000 0.000 0.046 0.046 0.093 0.604 0.930 0.232 0.000 1.953 SSE 0.000 0.000 0.000 0.046 0.000 0.186 0.604 0.930 0.093 1.860 S 0.000 0.000 0.093 0.139 0.046 0.139 0.418 0.232 0.000 1.069 SSW 0.000 0.046 0.000 0.046 0.093 0.186 0.325 0.000 0.000 0.697 SW 0.000 0.000 0.093 0.046 0.139 0.232 0.046 0.000 0.000 0.558 WSW 0.000 0.000 0.139 0.046 0.186 0.697 0.418 0.000 0.000 1.488 W 0.000 0.000 0.232 0.046 0.046 0.325 0.046 0.000 0.000 0.697 WNW 0.000 0.000 0.093 0.093 0.000 0.279 0.000 0.000 0.000 0.465 NW 0.000 0.000 0.232 0.046 0.093 0.139 0.046 0.000 0.000 0.558 NNW 0.000 0.000 0.046 0.000 0.000 0.093 0.093 0.000 0.000 0.232 SUBTOTAL 0.000 0.093 1.023 0.837 0.976 3.440 3.812 1.395 0.093 11.669 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2151 TOTAL HOURS OF STABILITY CLASS F 251 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F 251 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2151 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2022/04/07 MEAN WIND SPEED = 11.83 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 137 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2022 - MAR 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.093 NNE 0.000 0.000 0.046 0.000 0.000 0.000 0.046 0.000 0.000 0.093 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.093 E 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.046 0.000 0.000 0.000 0.093 0.000 0.000 0.139 SSE 0.000 0.000 0.046 0.000 0.000 0.046 0.000 0.000 0.000 0.093 S 0.000 0.046 0.000 0.000 0.000 0.325 0.093 0.000 0.000 0.465 SSW 0.000 0.000 0.046 0.000 0.000 0.000 0.046 0.000 0.000 0.093 SW 0.000 0.000 0.000 0.046 0.000 0.093 0.000 0.000 0.000 0.139 WSW 0.000 0.000 0.000 0.046 0.139 0.139 0.046 0.000 0.000 0.372 W 0.000 0.000 0.000 0.000 0.000 0.186 0.046 0.000 0.000 0.232 WNW 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 NW 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 NNW 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 SUBTOTAL 0.000 0.046 0.325 0.093 0.186 0.883 0.465 0.000 0.000 1.999 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2151 TOTAL HOURS OF STABILITY CLASS G 43 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G 43 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2151 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2022/04/07 MEAN WIND SPEED = 8.84 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 138 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data Table 8-B Elevated Releases - 2nd Quarter JFD Joint Frequency Distribution In Percent Page 139 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2165 TOTAL HOURS OF STABILITY CLASS A 1 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A 1 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2164 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2022/07/11 MEAN WIND SPEED = 13.60 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 140 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.046 0.277 0.000 0.000 0.323 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 SSE 0.000 0.000 0.000 0.000 0.046 0.046 0.046 0.000 0.000 0.139 S 0.000 0.000 0.000 0.046 0.000 0.092 0.000 0.000 0.000 0.139 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.092 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.277 0.000 0.000 0.000 0.277 WNW 0.000 0.000 0.000 0.000 0.000 0.185 0.046 0.000 0.000 0.231 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.000 0.000 0.092 SUBTOTAL 0.000 0.000 0.000 0.139 0.046 0.693 0.508 0.000 0.000 1.386 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2165 TOTAL HOURS OF STABILITY CLASS B 30 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B 30 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2164 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2022/07/11 MEAN WIND SPEED = 10.96 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 141 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.185 0.370 0.092 0.000 0.000 0.647 NNE 0.000 0.000 0.000 0.000 0.092 0.185 0.231 0.000 0.000 0.508 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 SE 0.000 0.000 0.000 0.092 0.000 0.185 0.092 0.000 0.000 0.370 SSE 0.000 0.000 0.000 0.046 0.139 0.185 0.046 0.000 0.000 0.416 S 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 SSW 0.000 0.000 0.000 0.000 0.092 0.046 0.000 0.000 0.000 0.139 SW 0.000 0.000 0.000 0.000 0.000 0.185 0.139 0.000 0.000 0.323 WSW 0.000 0.000 0.000 0.000 0.046 0.092 0.000 0.000 0.000 0.139 W 0.000 0.000 0.000 0.139 0.277 0.231 0.092 0.185 0.000 0.924 WNW 0.000 0.000 0.000 0.000 0.000 0.139 0.139 0.046 0.000 0.323 NW 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 NNW 0.000 0.000 0.000 0.000 0.000 0.139 0.092 0.000 0.000 0.231 SUBTOTAL 0.000 0.000 0.000 0.277 0.832 1.895 0.924 0.231 0.000 4.159 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2165 TOTAL HOURS OF STABILITY CLASS C 90 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 90 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2164 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2022/07/11 MEAN WIND SPEED = 10.67 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 142 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.092 0.462 1.710 0.924 0.092 0.000 3.281 NNE 0.000 0.000 0.000 0.185 0.231 1.571 0.277 0.046 0.000 2.311 NE 0.000 0.000 0.000 0.046 0.139 0.508 0.000 0.000 0.000 0.693 ENE 0.000 0.000 0.139 0.046 0.231 0.139 0.046 0.000 0.000 0.601 E 0.000 0.000 0.046 0.139 0.185 0.231 0.092 0.000 0.000 0.693 ESE 0.000 0.000 0.139 0.231 0.462 0.739 0.370 0.000 0.046 1.987 SE 0.000 0.000 0.139 1.109 0.508 1.109 1.756 1.201 0.277 6.100 SSE 0.000 0.000 0.416 0.601 0.601 1.109 1.479 1.340 0.185 5.730 S 0.000 0.000 0.231 0.508 0.462 1.201 2.588 1.109 0.000 6.100 SSW 0.000 0.000 0.185 0.508 0.416 0.832 2.126 1.063 0.092 5.222 SW 0.000 0.000 0.370 0.508 0.370 0.832 0.739 0.277 0.000 3.096 WSW 0.000 0.046 0.139 0.832 0.647 0.924 0.185 0.046 0.046 2.865 W 0.000 0.000 0.323 0.370 1.109 1.848 0.878 0.416 0.277 5.222 WNW 0.000 0.000 0.185 0.323 0.370 0.970 0.370 0.924 0.092 3.235 NW 0.000 0.000 0.139 0.231 0.416 0.786 1.433 0.462 0.000 3.466 NNW 0.000 0.000 0.046 0.046 0.046 1.109 0.786 0.092 0.000 2.126 SUBTOTAL 0.000 0.046 2.495 5.776 6.654 15.619 14.048 7.070 1.017 52.726 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2165 TOTAL HOURS OF STABILITY CLASS D 1142 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D 1141 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2164 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2022/07/11 MEAN WIND SPEED = 11.78 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 143 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.046 0.000 0.092 0.185 0.924 0.462 0.046 0.000 1.756 NNE 0.000 0.000 0.139 0.046 0.139 0.739 0.693 0.092 0.000 1.848 NE 0.000 0.000 0.046 0.139 0.092 0.462 1.109 0.046 0.000 1.895 ENE 0.000 0.000 0.000 0.000 0.046 0.416 0.231 0.000 0.000 0.693 E 0.000 0.000 0.092 0.000 0.092 0.277 0.092 0.000 0.000 0.555 ESE 0.000 0.000 0.092 0.231 0.046 0.462 0.231 0.046 0.000 1.109 SE 0.000 0.000 0.139 0.092 0.046 1.294 0.832 0.139 0.000 2.542 SSE 0.000 0.000 0.046 0.185 0.092 0.647 2.403 1.063 0.139 4.575 S 0.000 0.000 0.046 0.231 0.323 0.693 1.525 1.017 0.508 4.344 SSW 0.000 0.000 0.046 0.277 0.231 0.647 0.601 0.277 0.046 2.126 SW 0.000 0.000 0.000 0.231 0.231 0.323 0.092 0.000 0.000 0.878 WSW 0.000 0.000 0.092 0.000 0.370 0.508 0.000 0.000 0.000 0.970 W 0.000 0.046 0.046 0.231 0.046 0.231 0.092 0.000 0.000 0.693 WNW 0.000 0.000 0.000 0.092 0.277 0.370 0.000 0.046 0.000 0.786 NW 0.000 0.000 0.092 0.046 0.092 0.277 0.231 0.092 0.000 0.832 NNW 0.000 0.000 0.000 0.046 0.092 0.277 0.092 0.046 0.000 0.555 SUBTOTAL 0.000 0.092 0.878 1.941 2.403 8.549 8.688 2.911 0.693 26.155 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2165 TOTAL HOURS OF STABILITY CLASS E 566 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E 566 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2164 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2022/07/11 MEAN WIND SPEED = 12.32 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 144 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.092 0.786 0.000 0.000 0.878 NNE 0.000 0.000 0.046 0.046 0.000 0.185 0.508 0.092 0.000 0.878 NE 0.000 0.000 0.000 0.000 0.092 0.277 0.277 0.370 0.000 1.017 ENE 0.000 0.000 0.092 0.000 0.046 0.231 0.323 0.277 0.000 0.970 E 0.000 0.000 0.000 0.046 0.046 0.277 0.185 0.000 0.000 0.555 ESE 0.000 0.000 0.000 0.139 0.231 0.832 0.046 0.046 0.000 1.294 SE 0.000 0.000 0.185 0.231 0.139 0.508 0.416 0.000 0.000 1.479 SSE 0.000 0.000 0.000 0.046 0.185 0.416 0.647 0.092 0.046 1.433 S 0.000 0.000 0.046 0.185 0.000 0.185 0.601 0.000 0.000 1.017 SSW 0.000 0.000 0.000 0.092 0.000 0.231 0.231 0.046 0.000 0.601 SW 0.000 0.000 0.046 0.092 0.000 0.000 0.000 0.000 0.000 0.139 WSW 0.000 0.000 0.046 0.000 0.000 0.092 0.046 0.000 0.000 0.185 W 0.000 0.000 0.046 0.231 0.092 0.185 0.000 0.000 0.000 0.555 WNW 0.000 0.046 0.139 0.046 0.139 0.231 0.000 0.000 0.000 0.601 NW 0.000 0.000 0.000 0.185 0.092 0.231 0.046 0.000 0.000 0.555 NNW 0.000 0.000 0.000 0.046 0.000 0.231 0.000 0.000 0.000 0.277 SUBTOTAL 0.000 0.046 0.647 1.386 1.063 4.205 4.113 0.924 0.046 12.431 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2165 TOTAL HOURS OF STABILITY CLASS F 269 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F 269 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2164 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2022/07/11 MEAN WIND SPEED = 11.04 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 145 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2022 - JUN 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.046 0.000 0.000 0.046 0.000 0.000 0.000 0.092 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.139 0.000 0.000 0.139 NE 0.000 0.000 0.000 0.000 0.000 0.046 0.139 0.046 0.000 0.231 ENE 0.000 0.000 0.000 0.000 0.000 0.139 0.277 0.000 0.000 0.416 E 0.000 0.000 0.092 0.046 0.046 0.092 0.046 0.000 0.000 0.323 ESE 0.000 0.000 0.092 0.046 0.139 0.231 0.000 0.000 0.000 0.508 SE 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.092 SSE 0.000 0.000 0.092 0.000 0.139 0.323 0.000 0.000 0.000 0.555 S 0.000 0.000 0.000 0.092 0.139 0.046 0.046 0.000 0.000 0.323 SSW 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 SW 0.000 0.046 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.139 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 WNW 0.000 0.000 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.092 NW 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 NNW 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 SUBTOTAL 0.000 0.092 0.416 0.370 0.555 0.970 0.647 0.046 0.000 3.096 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2165 TOTAL HOURS OF STABILITY CLASS G 67 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G 67 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2164 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2022/07/11 MEAN WIND SPEED = 8.84 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 146 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data Table 8-C Elevated Releases - 3rd Quarter JFD Joint Frequency Distribution In Percent Page 147 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.000 0.000 0.000 0.045 0.000 0.045 0.000 0.000 0.091 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.091 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.091 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.000 0.045 0.182 0.045 0.000 0.000 0.273 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2198 TOTAL HOURS OF STABILITY CLASS A 6 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A 6 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2198 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2022/10/12 MEAN WIND SPEED = 9.95 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 148 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.227 0.045 0.000 0.273 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.000 0.000 0.000 0.045 0.045 0.045 0.000 0.000 0.136 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.000 0.000 0.091 0.273 0.045 0.000 0.000 0.409 SW 0.000 0.000 0.000 0.136 0.136 0.364 0.045 0.000 0.000 0.682 WSW 0.000 0.000 0.000 0.136 0.000 0.182 0.045 0.000 0.000 0.364 W 0.000 0.000 0.000 0.091 0.318 0.182 0.045 0.045 0.000 0.682 WNW 0.000 0.000 0.000 0.000 0.091 0.045 0.000 0.000 0.000 0.136 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.364 0.682 1.092 0.455 0.091 0.000 2.684 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2198 TOTAL HOURS OF STABILITY CLASS B 59 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B 59 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2198 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2022/10/12 MEAN WIND SPEED = 9.78 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 149 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.182 0.227 0.091 0.000 0.500 NNE 0.000 0.000 0.000 0.000 0.000 0.091 0.227 0.091 0.000 0.409 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.136 0.000 0.000 0.136 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.045 SSE 0.000 0.000 0.000 0.091 0.136 0.182 0.000 0.000 0.000 0.409 S 0.000 0.000 0.000 0.000 0.045 0.182 0.045 0.000 0.000 0.273 SSW 0.000 0.000 0.000 0.136 0.136 0.455 0.000 0.000 0.000 0.728 SW 0.000 0.000 0.045 0.182 0.091 0.409 0.227 0.000 0.000 0.955 WSW 0.000 0.000 0.000 0.318 0.273 0.273 0.000 0.000 0.000 0.864 W 0.000 0.000 0.000 0.182 0.273 0.364 0.045 0.000 0.000 0.864 WNW 0.000 0.000 0.000 0.000 0.091 0.227 0.045 0.000 0.000 0.364 NW 0.000 0.000 0.000 0.000 0.091 0.000 0.045 0.000 0.000 0.136 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.045 0.000 0.091 SUBTOTAL 0.000 0.000 0.045 0.910 1.183 2.366 1.046 0.227 0.000 5.778 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2198 TOTAL HOURS OF STABILITY CLASS C 127 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 127 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2198 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2022/10/12 MEAN WIND SPEED = 9.39 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 150 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.045 0.182 0.227 0.773 0.637 0.136 0.000 2.002 NNE 0.000 0.000 0.000 0.045 0.182 1.547 0.500 0.000 0.000 2.275 NE 0.000 0.000 0.182 0.227 0.182 0.500 0.091 0.045 0.045 1.274 ENE 0.000 0.000 0.227 0.136 0.227 0.182 0.000 0.000 0.000 0.773 E 0.000 0.045 0.136 0.136 0.000 0.273 0.045 0.000 0.000 0.637 ESE 0.000 0.000 0.182 0.318 0.182 0.819 0.455 0.000 0.000 1.956 SE 0.000 0.000 0.409 1.501 1.092 1.865 0.864 0.091 0.000 5.823 SSE 0.000 0.045 0.409 1.228 0.773 1.911 0.500 0.000 0.000 4.868 S 0.000 0.000 0.409 1.365 1.547 2.957 0.455 0.045 0.000 6.779 SSW 0.000 0.000 0.682 1.137 1.365 3.503 1.456 0.136 0.000 8.280 SW 0.000 0.000 0.546 1.547 1.956 2.138 0.728 0.000 0.000 6.915 WSW 0.000 0.000 0.409 1.638 1.365 1.547 0.182 0.000 0.000 5.141 W 0.000 0.000 0.091 0.546 0.637 1.410 0.409 0.000 0.000 3.094 WNW 0.000 0.000 0.045 0.091 0.182 0.773 0.136 0.000 0.000 1.228 NW 0.000 0.000 0.045 0.091 0.136 0.273 0.227 0.000 0.000 0.773 NNW 0.000 0.000 0.045 0.182 0.091 0.455 0.318 0.000 0.000 1.092 SUBTOTAL 0.000 0.091 3.867 10.373 10.146 20.928 7.006 0.455 0.045 52.912 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2198 TOTAL HOURS OF STABILITY CLASS D 1163 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D 1163 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2198 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2022/10/12 MEAN WIND SPEED = 8.21 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 151 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.045 0.136 0.591 0.500 0.091 0.000 1.365 NNE 0.000 0.000 0.045 0.227 0.182 1.137 1.456 0.227 0.000 3.276 NE 0.000 0.000 0.045 0.045 0.182 0.182 0.773 0.136 0.000 1.365 ENE 0.000 0.000 0.091 0.091 0.045 0.182 0.182 0.000 0.000 0.591 E 0.000 0.000 0.182 0.091 0.091 0.364 0.136 0.000 0.000 0.864 ESE 0.000 0.000 0.136 0.182 0.045 0.500 0.227 0.000 0.000 1.092 SE 0.000 0.000 0.136 0.227 0.500 1.865 0.455 0.045 0.000 3.230 SSE 0.000 0.000 0.364 0.273 0.409 1.092 0.091 0.000 0.000 2.229 S 0.000 0.045 0.273 0.637 0.591 0.910 0.728 0.000 0.000 3.185 SSW 0.000 0.000 0.227 0.409 0.273 0.910 0.455 0.000 0.000 2.275 SW 0.000 0.000 0.455 0.318 0.227 0.500 0.136 0.000 0.000 1.638 WSW 0.000 0.000 0.136 0.273 0.318 0.318 0.045 0.000 0.000 1.092 W 0.000 0.000 0.136 0.182 0.273 0.500 0.091 0.000 0.000 1.183 WNW 0.000 0.045 0.136 0.045 0.227 0.455 0.045 0.045 0.000 1.001 NW 0.000 0.000 0.136 0.227 0.000 0.136 0.136 0.045 0.000 0.682 NNW 0.000 0.000 0.045 0.091 0.091 0.227 0.136 0.000 0.000 0.591 SUBTOTAL 0.000 0.091 2.548 3.367 3.594 9.873 5.596 0.591 0.000 25.660 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2198 TOTAL HOURS OF STABILITY CLASS E 564 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E 564 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2198 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2022/10/12 MEAN WIND SPEED = 9.28 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 152 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.045 0.045 0.000 0.182 0.364 0.136 0.000 0.773 NNE 0.000 0.000 0.045 0.000 0.000 0.273 0.637 0.136 0.000 1.092 NE 0.000 0.000 0.000 0.091 0.182 0.409 0.409 0.227 0.000 1.319 ENE 0.000 0.000 0.000 0.045 0.045 0.409 0.182 0.000 0.000 0.682 E 0.000 0.045 0.000 0.091 0.045 0.045 0.182 0.000 0.000 0.409 ESE 0.000 0.000 0.091 0.227 0.182 0.136 0.000 0.000 0.000 0.637 SE 0.000 0.000 0.000 0.318 0.273 0.819 0.000 0.000 0.000 1.410 SSE 0.000 0.000 0.000 0.182 0.091 0.637 0.000 0.000 0.000 0.910 S 0.000 0.000 0.045 0.091 0.091 0.000 0.000 0.000 0.000 0.227 SSW 0.000 0.000 0.091 0.000 0.000 0.136 0.227 0.000 0.000 0.455 SW 0.000 0.000 0.045 0.045 0.136 0.045 0.000 0.000 0.000 0.273 WSW 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.045 W 0.000 0.045 0.000 0.136 0.091 0.045 0.045 0.000 0.000 0.364 WNW 0.000 0.000 0.045 0.045 0.136 0.136 0.000 0.000 0.000 0.364 NW 0.000 0.000 0.045 0.045 0.045 0.091 0.000 0.000 0.000 0.227 NNW 0.000 0.000 0.000 0.000 0.000 0.227 0.136 0.136 0.000 0.500 SUBTOTAL 0.000 0.091 0.455 1.365 1.365 3.594 2.184 0.637 0.000 9.691 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2198 TOTAL HOURS OF STABILITY CLASS F 213 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F 213 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2198 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2022/10/12 MEAN WIND SPEED = 10.18 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 153 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data JUL 1, 2022 - SEP 30, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.045 0.000 0.000 0.045 0.000 0.000 0.000 0.091 NNE 0.000 0.000 0.000 0.045 0.045 0.045 0.273 0.273 0.045 0.728 NE 0.000 0.000 0.000 0.000 0.000 0.182 0.091 0.318 0.000 0.591 ENE 0.000 0.000 0.045 0.045 0.136 0.136 0.273 0.000 0.000 0.637 E 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.045 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.091 0.000 0.091 0.000 0.000 0.000 0.000 0.182 SSE 0.000 0.000 0.045 0.000 0.091 0.000 0.000 0.000 0.000 0.136 S 0.000 0.000 0.000 0.045 0.045 0.000 0.000 0.000 0.000 0.091 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.045 0.000 0.000 0.045 0.000 0.000 0.000 0.091 WSW 0.000 0.000 0.000 0.045 0.045 0.000 0.000 0.000 0.000 0.091 W 0.000 0.000 0.091 0.045 0.045 0.000 0.000 0.000 0.000 0.182 WNW 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.045 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.045 0.000 0.045 0.000 0.000 0.091 SUBTOTAL 0.000 0.000 0.409 0.227 0.546 0.500 0.682 0.591 0.045 3.003 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2198 TOTAL HOURS OF STABILITY CLASS G 66 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G 66 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2198 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: Browns Ferry Nuclear Plant STA 52 D - Validated Edited Data STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2022/10/12 MEAN WIND SPEED = 11.63 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 154 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data Table 8-D Elevated Releases - 4th Quarter JFD Joint Frequency Distribution In Percent Page 155 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2202 TOTAL HOURS OF STABILITY CLASS A 0 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A 0 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2036 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2023/01/05 MEAN WIND SPEED = 0.00 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 156 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.049 0.098 0.000 0.000 0.147 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.049 0.000 0.000 0.000 0.000 0.000 0.049 WSW 0.000 0.000 0.000 0.049 0.000 0.000 0.000 0.000 0.000 0.049 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.049 0.000 0.049 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.049 0.000 0.000 0.049 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.147 0.000 0.000 0.147 SUBTOTAL 0.000 0.000 0.000 0.098 0.000 0.049 0.295 0.049 0.000 0.491 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2202 TOTAL HOURS OF STABILITY CLASS B 10 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B 10 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2036 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2023/01/05 MEAN WIND SPEED = 13.29 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 157 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.246 0.442 0.098 0.000 0.786 NNE 0.000 0.000 0.000 0.000 0.000 0.098 0.049 0.000 0.000 0.147 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.049 0.000 0.000 0.000 0.049 SE 0.000 0.000 0.000 0.000 0.049 0.000 0.049 0.000 0.000 0.098 SSE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.147 0.000 0.000 0.000 0.000 0.000 0.147 WSW 0.000 0.000 0.049 0.000 0.000 0.196 0.098 0.000 0.000 0.344 W 0.000 0.000 0.000 0.000 0.049 0.246 0.589 0.049 0.000 0.933 WNW 0.000 0.000 0.000 0.000 0.000 0.049 0.246 0.098 0.000 0.393 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.098 0.000 0.000 0.098 NNW 0.000 0.000 0.000 0.000 0.000 0.049 0.295 0.000 0.000 0.344 SUBTOTAL 0.000 0.000 0.049 0.147 0.098 0.933 1.866 0.246 0.000 3.340 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2202 TOTAL HOURS OF STABILITY CLASS C 71 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 68 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2036 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2023/01/05 MEAN WIND SPEED = 13.03 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 158 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.196 0.098 0.000 0.688 0.688 0.049 0.000 1.719 NNE 0.000 0.000 0.147 0.147 0.246 1.670 0.442 0.000 0.000 2.652 NE 0.000 0.000 0.049 0.295 0.196 0.688 0.049 0.000 0.000 1.277 ENE 0.000 0.000 0.000 0.246 0.442 0.295 0.098 0.000 0.000 1.081 E 0.000 0.000 0.000 0.246 0.246 0.147 0.049 0.000 0.000 0.688 ESE 0.000 0.000 0.049 0.049 0.639 1.621 1.031 0.196 0.000 3.585 SE 0.000 0.000 0.000 0.000 0.196 1.228 1.277 1.768 0.884 5.354 SSE 0.000 0.000 0.147 0.196 0.098 0.688 1.375 0.196 0.246 2.947 S 0.000 0.000 0.246 0.295 0.098 0.639 0.442 0.344 0.000 2.063 SSW 0.000 0.000 0.147 0.098 0.196 0.147 0.442 0.000 0.000 1.031 SW 0.000 0.000 0.049 0.147 0.049 0.884 0.442 0.000 0.000 1.572 WSW 0.000 0.000 0.098 0.147 0.147 1.375 0.786 0.049 0.000 2.603 W 0.000 0.000 0.147 0.344 0.196 1.473 1.866 0.344 0.147 4.519 WNW 0.000 0.000 0.098 0.196 0.344 1.768 0.589 0.639 0.246 3.880 NW 0.000 0.000 0.049 0.098 0.147 1.424 1.081 0.442 0.344 3.585 NNW 0.000 0.000 0.049 0.196 0.246 0.982 2.161 0.196 0.000 3.831 SUBTOTAL 0.000 0.000 1.473 2.800 3.487 15.717 12.819 4.224 1.866 42.387 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2202 TOTAL HOURS OF STABILITY CLASS D 921 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D 863 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2036 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2023/01/05 MEAN WIND SPEED = 12.60 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 159 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.049 0.147 0.049 0.246 0.786 0.049 0.000 1.326 NNE 0.000 0.000 0.098 0.098 0.098 1.916 1.228 0.098 0.000 3.536 NE 0.000 0.000 0.049 0.147 0.000 1.081 1.228 0.000 0.000 2.505 ENE 0.000 0.000 0.049 0.147 0.147 0.393 0.196 0.049 0.000 0.982 E 0.000 0.000 0.098 0.442 0.049 0.589 0.295 0.000 0.000 1.473 ESE 0.000 0.049 0.147 0.344 0.196 0.786 1.523 0.098 0.000 3.143 SE 0.000 0.000 0.098 0.000 0.688 1.081 2.014 1.081 0.246 5.206 SSE 0.000 0.000 0.098 0.147 0.049 1.179 1.768 1.670 0.491 5.403 S 0.000 0.049 0.000 0.098 0.049 0.933 1.081 0.393 0.049 2.652 SSW 0.000 0.000 0.098 0.098 0.442 0.835 1.277 0.442 0.000 3.193 SW 0.000 0.000 0.147 0.049 0.295 1.081 0.049 0.147 0.000 1.768 WSW 0.000 0.000 0.000 0.147 0.295 0.442 0.196 0.049 0.000 1.130 W 0.000 0.000 0.049 0.344 0.098 0.491 0.196 0.000 0.000 1.179 WNW 0.000 0.000 0.000 0.049 0.147 0.295 0.147 0.000 0.000 0.639 NW 0.000 0.000 0.098 0.196 0.098 0.295 0.196 0.196 0.000 1.081 NNW 0.000 0.000 0.147 0.049 0.098 0.491 0.982 0.344 0.000 2.112 SUBTOTAL 0.000 0.098 1.228 2.505 2.800 12.132 13.163 4.617 0.786 37.328 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2202 TOTAL HOURS OF STABILITY CLASS E 806 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E 760 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2036 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2023/01/05 MEAN WIND SPEED = 12.69 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 160 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.049 0.098 0.000 0.049 0.589 0.098 0.000 0.884 NNE 0.000 0.000 0.000 0.000 0.000 0.098 0.442 0.049 0.000 0.589 NE 0.000 0.000 0.000 0.000 0.098 0.393 0.933 0.000 0.000 1.424 ENE 0.000 0.000 0.098 0.000 0.098 0.049 0.393 0.049 0.000 0.688 E 0.000 0.000 0.147 0.098 0.049 0.295 0.147 0.000 0.000 0.737 ESE 0.000 0.000 0.000 0.098 0.049 0.295 0.491 0.098 0.000 1.031 SE 0.000 0.000 0.000 0.049 0.098 0.393 0.786 0.049 0.049 1.424 SSE 0.000 0.000 0.000 0.000 0.049 0.442 1.228 0.786 0.000 2.505 S 0.000 0.000 0.000 0.000 0.049 0.196 0.540 0.000 0.000 0.786 SSW 0.000 0.000 0.098 0.000 0.049 0.196 0.049 0.000 0.000 0.393 SW 0.000 0.049 0.049 0.147 0.098 0.049 0.000 0.000 0.000 0.393 WSW 0.000 0.000 0.049 0.098 0.098 0.049 0.000 0.000 0.000 0.295 W 0.000 0.000 0.000 0.147 0.049 0.000 0.000 0.000 0.000 0.196 WNW 0.000 0.000 0.000 0.000 0.196 0.000 0.000 0.000 0.000 0.196 NW 0.000 0.000 0.000 0.246 0.098 0.049 0.000 0.000 0.000 0.393 NNW 0.000 0.000 0.000 0.147 0.098 0.147 0.000 0.000 0.000 0.393 SUBTOTAL 0.000 0.049 0.491 1.130 1.179 2.701 5.599 1.130 0.049 12.328 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2202 TOTAL HOURS OF STABILITY CLASS F 288 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F 251 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2036 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2023/01/05 MEAN WIND SPEED = 12.30 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 161 of 162
Browns Ferry Nuclear Plant Units 1, 2 and 3 2022 Annual Radioactive Effluent Release Report Meteorological Data JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2022 - DEC 31, 2022 WIND WIND SPEED(MPH)
DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.049 0.000 0.000 0.000 0.000 0.000 0.000 0.049 NNE 0.000 0.000 0.049 0.000 0.000 0.147 0.196 0.000 0.000 0.393 NE 0.000 0.000 0.000 0.049 0.098 0.098 0.393 0.246 0.000 0.884 ENE 0.000 0.000 0.049 0.000 0.049 0.295 0.196 0.049 0.000 0.639 E 0.000 0.000 0.000 0.000 0.049 0.049 0.000 0.000 0.000 0.098 ESE 0.000 0.000 0.049 0.000 0.049 0.196 0.000 0.000 0.000 0.295 SE 0.000 0.000 0.049 0.049 0.049 0.196 0.049 0.000 0.000 0.393 SSE 0.000 0.000 0.000 0.000 0.000 0.049 0.049 0.000 0.000 0.098 S 0.000 0.000 0.000 0.000 0.000 0.295 0.098 0.000 0.000 0.393 SSW 0.000 0.000 0.000 0.049 0.098 0.000 0.000 0.000 0.000 0.147 SW 0.000 0.049 0.049 0.000 0.098 0.000 0.000 0.000 0.000 0.196 WSW 0.000 0.000 0.000 0.000 0.049 0.000 0.000 0.000 0.000 0.049 W 0.000 0.000 0.000 0.049 0.000 0.049 0.000 0.000 0.000 0.098 WNW 0.000 0.000 0.000 0.049 0.000 0.049 0.000 0.000 0.000 0.098 NW 0.000 0.049 0.000 0.098 0.000 0.098 0.000 0.000 0.000 0.246 NNW 0.000 0.049 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.049 SUBTOTAL 0.000 0.147 0.295 0.344 0.540 1.523 0.982 0.295 0.000 4.126 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2202 TOTAL HOURS OF STABILITY CLASS G 106 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G 84 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2036 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2023/01/05 MEAN WIND SPEED = 10.17 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS Page 162 of 162