Tennessee Valley Authority, Post Office Box 2000, Decatur, Alabama 35609-2000 April 28, 2017 ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Browns Ferry Nuclear Plant, Units 1, 2, and 3 10 CFR 50.4 10 CFR 50.36a 10 CFR 50 Appendix I Renewed Facility Operating License Nos. DPR-33, DPR-52, and DPR-68 NRC Docket Nos. 50-259, 50-260, and 50-296

Subject:

2016 Annual Radioactive Effluent Release Report In accordance with the Browns Ferry Nuclear Plant (BFN), Units 1, 2, and 3, Technical Specification Section 5.6.3, the Tennessee Valley Authority is submitting the BFN Annual Radioactive Effluent Release Report for the period January through December 2016. This document is in conformance with Title 10 of the Code of Federal Regulations (10 CFR) 50.36a and 10 CFR 50, Appendix I,Section IV.B.1. to Enclosure 1 documents deviations which have occurred from Offsite Dose Calculation Manual (ODCM) controls and surveillance requirements. Attachment 2 to provides information on radiological effluent instrumentation inoperable for greater than 30 days.

There are no new regulatory commitments contained in this letter. Should you have any questions concerning this submittal, please contact Jamie Paul at (256) 729-7533.

S. M. Bono Site Vice President

U.S. Nuclear Regulatory Commission Page 2 April 28, 2017

Enclosure:

2016 Annual Radioactive Effluent Release Report cc (w/ Enclosure):

NRC Regional Administrator - Region II NRC Senior Resident Inspector - Browns Ferry Nuclear Plant

ENCLOSURE Browns Ferry Nuclear Plant Units 1, 2, and 3 2016 Annual Radioactive Effluent Release Report See Enclosed

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT TABLE OF CONTENTS E-1 Section Title Page Number Supplemental Information E-3 E-8 Gaseous Effluents E-9 E-16 Liquid Effluents E-17 E-19 Solid Waste E-20 E-26 Radiological Impact E-27 E-43 Meteorological Data E-44 E-167 - Deviations from ODCM Controls and Surveillance Requirements E-168 - Inoperable Radiological Effluent Instrumentation Report E-169 Groundwater Protection Program E-170 E-175 Tables Page Number Table 1A, Gaseous Effluents - Summation of All Releases E-9 Table 1B, Gaseous Effluents - Elevated Releases E-10 E-11 Table 1C, Gaseous Effluents - Ground Level Releases E-12 E-13 Table 1D, Gaseous Effluents - Mixed Mode Releases E-14 E-16 Table 2A, Liquid Effluents - Summation of All Releases E-17 Table 2B, Liquid Effluents E-18 E-19 Table 3, Solid Waste and Irradiated Fuel Shipments E-20 E-26 Table 4, Radiological Impact, Doses from Airborne Effluents E-34 E-37 Table 5, Radiological Impact, Doses from Liquid Effluents E-38 E-41 Table 5A, Radiological Impact, Total Doses from I-131 E-42 Water Ingestion Pathway Table 6, Radiological Impact, Total Dose from Fuel Cycle E-43 Table 7A, Meteorological Data, Joint Frequency Distribution E-44 E-51 Ground Level Releases, First Quarter

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT TABLE OF CONTENTS E-2 Tables Page Number Table 7B, Meteorological Data, Joint Frequency Distribution E-52 E-59 Ground Level Releases, Second Quarter Table 7C, Meteorological Data, Joint Frequency Distribution E-60 E-67 Ground Level Releases, Third Quarter Table 7D, Meteorological Data, Joint Frequency Distribution E-68 E-75 Ground Level Releases, Fourth Quarter Table 8A, Meteorological Data, Joint Frequency Distribution E-76 E-90 Split Level Releases, First Quarter Table 8B, Meteorological Data, Joint Frequency Distribution E-91 E-105 Split Level Releases, Second Quarter Table 8C, Meteorological Data, Joint Frequency Distribution E-106 E-120 Split Level Releases, Third Quarter Table 8D. Meteorological Data, Joint Frequency Distribution E-121 E-135 Split Level Releases, Fourth Quarter Table 9A, Meteorological Data, Joint Frequency Distribution E-136 E-143 Elevated Releases, First Quarter Table 9B, Meteorological Data, Joint Frequency Distribution E-144 E-151 Elevated Level Releases, Second Quarter Table 9C, Meteorological Data, Joint Frequency Distribution E-152 E-159 Elevated Level Releases, Third Quarter Table 9D, Meteorological Data, Joint Frequency Distribution E-160 E-167 Elevated Level Releases, Fourth Quarter

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT Supplemental Information E-3

1. Regulatory and BFN ODCM Limits
a. Fission and Activation Gases in Gaseous Effluent:

The release of fission and activation gases is regulated by the dose limits of Title 10 of the Code of Federal Regulations (10 CFR) 50 Appendix I and Browns Ferry Nuclear Plant (BFN) Offsite Dose Calculation Manual (ODCM). The air dose to areas at and beyond the site boundary due to noble gases released in gaseous effluents per unit shall be limited during any calendar quarter to 5 millirad (mrad) for gamma radiation and 10 mrad for beta radiation; and during any calendar year to 10 mrad for gamma radiation and 20 mrad for beta radiation.

b. Iodines and Particulates with Half-Lives Greater than Eight Days in Gaseous Effluents:

The release of iodines and particulates in gaseous effluent is regulated by the dose limits of 10 CFR 50 Appendix I and the BFN ODCM. The dose to a member of the public from radioiodines, radioactive materials in particulate form, and radionuclides other than noble gases with half-lives greater than eight days in gaseous effluent released per unit to areas at and beyond the site boundary shall be limited to any organ during any calendar quarter to 7.5 millirem (mrem), and during any calendar year to 15 mrem.

c. Liquid Effluents:

The release of radioactive liquid effluents is regulated by the dose limits of 10 CFR 50 Appendix I and the BFN ODCM. The doses or dose commitment to a member of the public from radioactive materials in liquid effluents released from each unit to unrestricted areas shall be limited during any calendar quarter to 1.5 mrem to the total body and 5 mrem to any organ and during any calendar year to 3 mrem to the total body and 10 mrem to any organ.

2. Limitation on Dose Rate
a. Fission and Activation Gases in Gaseous Effluent:
1. The instantaneous release rate of fission and activation gases is based on the dose rate limits of 10 CFR 20.1301 and the BFN ODCM. The dose rate at any time to areas at and beyond the site boundary due to noble gases released in gaseous effluents from the site shall be limited to 500 mrem per year to the total body and 3000 mrem per year to the skin.
2. The BFN ODCM Section 7.2 determines the maximum noble gas release rate.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT Supplemental Information E-4

2. Limitation on Dose Rate (Continued)
b. Iodines and Particulates with Half-Lives Greater than Eight Days in Gaseous Effluents:
1. The instantaneous release rate of particulates and iodines is regulated by the dose rate limits of the BFN ODCM. The dose rate at any time to areas at and beyond the site boundary, due to I-131, I-133, H-3, and particulates with half-lives greater than eight days in gaseous effluent released from the site, shall be limited to 1500 mrem per year to any organ.
2. The BFN ODCM Section 7.3 determines the maximum particulate and iodine dose rates.
c. Liquid Effluents:
1. The concentration of radionuclides in liquid effluents released at any time from the site to unrestricted areas shall be limited to the concentrations specified in 10 CFR 20.1001-20.2402, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases
2. For dissolved or entrained noble gases, the concentration shall be limited to 2E-4 Ci per milliliter (ml) total activity.
3. Average Energy The BFN ODCM limits the dose equivalent rates due to the release of noble gases to less than or equal to 500 mrem/year to the total body and less than or equal to 3000 mrem/year to the skin. The use of dose rate is in accordance with NUREG-0133, "Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants."

Since the release rate is not used for effluent control, the average beta and gamma energies (E) for gaseous effluents discussed in Regulatory Guide 1.21, "Measuring, Evaluation, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants," are not applicable and not included in this report.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT Supplemental Information E-5

4. Measurements and Approximations of Total Radioactivity
a. Fission and activation gases:
1. Noble gases in the building vent and stack (elevated) gaseous effluents are continuously monitored. The flow rate of the stack is continuously monitored and the building vent effluent flow rates are calculated once a shift based on the configuration of operating exhaust fans. The vent flow is calculated for each release. Gas grab samples of the stack are taken and analyzed weekly. Gas grab samples of in-service vents are taken and analyzed monthly. The specific noble gas activity concentrations and total volume of the gases are used to calculate the total Curies of noble gases released.
2. The tritium concentration is determined by the analysis of a monthly grab sample for each release point.
b. Iodines and Particulates:
1. Iodines and particulates are continuously sampled on impregnated charcoal filters and particulate filters, respectively. The charcoal and particulate samples are replaced at least weekly and analyzed to determine specific activity concentrations. The specific activity concentrations and vent flow rate data are used weekly to verify that release rate limits were not exceeded. The specific activity concentrations and total volume of gaseous effluent are used on a monthly basis to determine the total curies of each particulate and iodine released during the month.
2. The gross alpha concentration is determined by analysis of a monthly particulate filter composite sample, and strontium-89 and strontium-90 are determined by analysis of a quarterly particulate filter composite sample for each release point.
c. Liquid effluents:
1. The gamma ray emitting radionuclide concentrations are determined for each batch by gamma ray spectroscopy analysis of a grab sample. The allowable release rate is calculated for each batch based upon the known dilution flow.

The flow rate of the liquid effluent is continuously monitored and the total volume released in each batch is determined. The total gamma activity released in each batch is determined by multiplying the radionuclide concentrations by the total volume discharged. The total gamma activity released during the month is then determined by summing the gamma activity content of each batch discharged during the month.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT Supplemental Information E-6

4. Measurements and Approximations of Total Radioactivity (Continued) c.

Liquid effluents (Continued):

2. The gross alpha and tritium concentrations are measured on a monthly composite sample. The strontium-89, strontium-90, and iron-55 are measured on a quarterly composite sample.
d. The Radioactive Gaseous and Liquid Waste Monitoring Sampling and Analysis Program is specified in ODCM Sections 1/2.2.1 and 1/2.2.2. No liquid or gaseous concentration or dose limits were exceeded.
5. Batch Releases Quarter Quarter Quarter Quarter A.

Liquid Units 1

2 3

4

1. Number of batches released Each 1

1 11 10

2. Total time for batches released Minutes 140.00 175.00 3310.00 2044.00
3. Maximum time period for a batch release Minutes 140.00 175.00 405.00 250.00
4. Average time period for a batch release Minutes 140.00 175.00 300.91 204.40
5. Minimum time period for a batch release Minutes 140.00 175.00 150.00 110.00
6. Average BFN batch flow during period of release into the river stream ft3/sec 90,195 11,354 15,271 17,169 B.

Gaseous None

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT Supplemental Information E-7

6. Abnormal Releases
a. Liquid
1. Number of releases: 4
2. Total activity released (Curies):
b. Gaseous
1. Number of releases: 0
6. Abnormal Releases (Continued)

Summary of Abnormal/Unplanned Releases The release of radioactive material to the environment from BFN has been a small fraction of the 10 CFR 20 Appendix B and 10 CFR 50 Appendix I limits. There were no limits exceeded as specified in 10 CFR 20 Appendix B and 10 CFR 50 Appendix I.

Four abnormal liquid releases occurred in 2016.

1.

Three of the abnormal releases were from the U1, U2, and U3 Station Sumps.

These releases occurred throughout 2016 and were the result of several identified sources including multiple steam leaks which occurred in the U-1, U-2 and U-3 Steam Jet Air Ejector Rooms along with the U-1 and U-2 Recombiner Rooms and U-2 Moisture Separator Room.

(CRs 1205661, 1206175, 1207246, 1240249, 1240570, 1255845, 1250531)

2.

During a walkdown of the Reactor Bldg roof, a leak coming from the U-2B Turbine Building exhaust (2-FAN-064-0047B) was discovered. This leak was coming from the warped expansion joints around the exhaust duct and falling onto the Reactor Bldg roof. (CR 1241503)

Destination Nuclide Quarter 1 Quarter 2 Quarter 3 Quarter 4 Leak to River H-3 2.19E+00 8.30E-01 4.50E-01 1.12E+00 F-18 7.93E-02 3.12E-02

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT Supplemental Information E-8

7. Missed Compensatory Samples During the reporting period, January 1, 2016 through December 31, 2016, there was one missed compensatory sample.

CR 1194524 was flagged as a potential for a missed ODCM required compensatory sample.

Review of the CR and the identified surveillance, 0-SI-4.8.A.1-1 (Liquid Effluent Permit) performance, determined a procedure violation occurred with the incorrect attachment completed by Operations personnel. Performance of the wrong attachment during the release resulted in the requirements of ODCM, Table 1.1-1, Action E for 0-FIC-77-60, Radwaste Discharge Flow Loop when inoperable not being met for that release.

The completion of the correct attachment would have satisfied the ODCM requirement in Table 1.1-1, instrument 4, Action E stated below.

With the number of channels OPERABLE less than required by the Minimum Channels OPERABLE requirement, effluent releases via this pathway may be continued provided the flow rate is estimated at least once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> during actual releases. Pump curves may be used to estimate flow.

During the final review of this surveillance, calculations were performed, utilizing the data collected and the correct attachment, which subsequently verified the operability of the 0-FIC-77-60.

8. Changes to the Radwaste System and Changes to the Process Control Program In calendar year 2016, BFN had no permanent changes to the Radwaste System or the Process Control Program.
9. Revisions to the Offsite Dose Calculation Manual (ODCM)

During 2016 there were no revisions made to the Offsite Dose Calculation Manual (ODCM).

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT GASEOUS EFFLUENTS E-9 TABLE 1A Page 1 of 1 Gaseous Effluents - Summation of All Releases Units Quarter 1 Quarter 2 Quarter 3 Quarter 4 Error A. Fission and Activation Gases

1. Total Releases Curies 45
2. Average Release Rate for Period Ci/sec
3. Percent of Applicable Limit B. Iodines
1. Total Iodine-131 Curies 2.694E-04 2.719E-04 3.112E-04 1.937E-04 36
2. Average Release Rate for Period Ci/sec 3.427E-05 3.458E-05 3.915E-05 2.436E-05
3. Percent of Applicable Limit C. Particulates
1. Particulates with half-lives

> eight days Curies 7.470E-04 1.134E-03 6.657E-04 6.939E-04 35

2. Average Release Rate for Period Ci/sec 9.501E-05 1.442E-04 8.375E-05 8.729E-05
3. Percent of Applicable Limit
4. Gross Alpha Radioactivity Curies D. Tritium
1. Total Release Curies 1.854E+02 9.903E+0 1

4.754E+01 1.744E+02 21

2. Average Release Rate for Period Ci/sec 2.358E+01 1.259E+0 1

5.980E+00 2.194E+01

3. Percent of Applicable Limit E. Carbon-14***
1. Total Release Curies 7.804 9.515 9.270 8.381
2. Total as CO2 Curies 8.215 10.016 9.758 8.822
  • - Includes Activity from Abnormal Release
    • - Not Detected.
      • - Estimated using EPRI methodology provided in EPRI Report 1021106.
        • - Applicable Limits are expressed in terms of dose. See Radiological Impact Section.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT GASEOUS EFFLUENTS (Continuous Mode Only)

E-10 TABLE 1B Page 1 of 2 Gaseous Effluents - Elevated Releases CURIES Quarter 1 Quarter 2 Quarter 3 Quarter 4

1. Fission Gases Kr-85m Kr-85 Kr-87 Kr-88 Xe-133 Xe-135m Xe-135 Xe-138 Others Total for Period
2.

Iodines I-131 5.31E-05 1.26E-04 1.26E-04 6.20E-05 I-135 I-133 9.83E-05 4.18E-04 3.55E-04 1.32E-04 Total for Period 1.51E-04 5.44E-04 4.81E-04 1.94E-04

    • - Not Detected.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT GASEOUS EFFLUENTS (Continuous Mode Only)

E-11 TABLE 1B (Continued)

Page 2 of 2 Gaseous Effluents - Elevated Releases CURIES Quarter 1 Quarter 2 Quarter 3 Quarter 4

3.

Particulates*

Sr-89 9.46E-06 1.82E-05 2.19E-05 Sr-90 Sr-91 7.75E-06 Br-84 Cs-138 1.00E-03 5.58E-03 1.18E-02 1.73E-03 Ba-140 7.72E-06 5.27E-06 5.04E-06 La-140 6.42E-07 3.27E-06 Te-132 Zn-69m Others (Au-199) 2.10E-05 1.98E-05 5.72E-06 3.31E-05 Rb-88 Rb-89 Y-91m 4.62E-05 7.62E-05 8.72E-05 5.83E-05 Co-60 3.87E-06 1.71E-06 Ba-139 1.21E-02 1.33E-02 2.19E-02 1.99E-02 Total for Period*

1.32E-02 1.90E-02 3.38E-02 2.17E-02

4.

Tritium 4.29E+00 3.10E+00 3.17E+00 1.76E+00

5.

Carbon-14***

7.804 9.515 9.270 8.381

  • - Includes all nuclides, even those with less than an eight day half-life.
    • - Not Detected.
      • - Estimated using EPRI methodology provided in EPRI Report 1021106.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT GASEOUS EFFLUENTS (Continuous Mode Only)

E-12 TABLE 1C Page 1 of 2 Gaseous Effluents - Ground Level Releases CURIES Quarter 1 Quarter 2 Quarter 3 Quarter 4

1. Fission Gases Kr-85m Kr-85 Kr-87 Kr-88 Xe-133 Xe-135m Xe-135 Xe-138 Ar-41 Other (specify)

Total for Period

2.

Iodines I-131 8.24E-05 1.72E-05 2.12E-05 3.25E-05 I-132 I-133 2.03E-04 3.66E-05 2.89E-05 4.39E-05 Total for Period 2.85E-04 5.39E-05 5.01E-05 7.64E-05

    • - Not Detected.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT GASEOUS EFFLUENTS (Continuous Mode Only)

E-13 TABLE 1C (Continued)

Page 2 of 2 Gaseous Effluents - Ground Level Releases CURIES Quarter 1 Quarter 2 Quarter 3 Quarter 4

3. Particulates*

Co-60 5.82E-05 1.42E-04 2.98E-05 2.03E-05 Sr-89 Sr-90 Cs-134 Cs-137 9.35E-07 7.05E-07 Ba-140 Sr-91 Tc-99m Mo-99 Y-91m 7.94E-06 Cs-138 6.77E-03 Ba-139 4.27E-04 Total for Period*

6.84E-03 1.42E-04 3.07E-05 4.48E-04 Tritium 7.04E+01 1.52E+01 2.76E+00 5.50E+00

  • - Include all nuclides even those with less than an eight day half-life.
    • - Not Detected.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT GASEOUS EFFLUENTS (Continuous Mode Only)

E-14 TABLE 1D Page 1 of 3 Gaseous Effluents - Mixed Mode Releases*

CURIES Quarter 1 Quarter 2 Quarter 3 Quarter 4

1.

Fission Gases Kr-85m Kr-85 Kr-87 Kr-88 Xe-133 Xe-135m Xe-135 Xe-138 Other (specify)

Total for Period

2.

Iodines I-131 1.34E-04 1.29E-04 1.64E-04 9.92E-05 I-132 I-133 4.85E-04 7.25E-04 7.20E-04 5.87E-04 Total for Period 6.19E-04 8.54E-04 8.84E-04 6.86E-04

  • - The Reactor Building and Radwaste Building are treated as split-level releases.
    • - Not Detected.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT GASEOUS EFFLUENTS (Continuous Mode Only)

E-15 TABLE 1D (Continued)

Page 2 of 3 Gaseous Effluents - Mixed Mode Releases*

CURIES Quarter 1 Quarter 2 Quarter 3 Quarter 4

3.

Particulates***

Sr-89 Ag-110m 3.72E-06 6.57E-06 1.59E-05 Cs-137 7.26E-07 6.67E-06 2.03E-06 9.54E-06 Ba-140 1.85E-05 La-140 Na-24 Mn-54 3.06E-05 1.65E-06 1.27E-05 Mn-56 3.78E-04 3.69E-03 Cr-51 8.64E-05 1.92E-05 Co-58 3.33E-05 Co-60 4.59E-04 9.63E-04 5.98E-04 4.71E-04 Zn-65 1.45E-05 8.12E-05 Y-91m 2.37E-04 1.02E-04 5.41E-05 Sr-91 Sr-92 Cs-138 Ba-139 4.27E-03 2.08E-03 Y-92 Ni-65 Other (Se-75) 1.54E-06

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT GASEOUS EFFLUENTS (Continuous Mode Only)

E-16 TABLE 1D (Continued)

Page 3 of 3 Gaseous Effluents - Mixed Mode Releases*

CURIES Quarter 1 Quarter 2 Quarter 3 Quarter 4

3.

Particulates***

Cs-134 Co-57 Sb-124 Tc-99m Mo-99 Zn-69m 4.37E-05 3.59E-05 Fe-59 Total for Period**

5.58E-03 9.72E-04 4.43E-03 2.74E-03 Tritium 1.11E+02 8.07E+01 4.16E+01 1.67E+02

  • - The Reactor Building and Radwaste Building are treated as split-level releases.
    • - Not Detected.
      • - Includes all nuclides, even those with less than an eight day half-life.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT LIQUID EFFLUENTS E-17 TABLE 2A Page 1 of 1 Liquid Effluents - Summation of All Releases Units Quarter 1 Quarter 2 Quarter 3 Quarter 4 Error %

A. Fission and Activation Products (Does not include tritium, gases, alpha)

1.

Total Release Curies 5.239E-04 2.924E-04 8.61E-02** 5.06E-02**

9

2.

Average Diluted Concentration Released During the Period Ci/ml 8.236E-10 7.356E-10 1.397E-08** 1.282E-08**

3.

Percent of Applicable Limit B. Tritium

1.

Total Releases Curies 2.20E+00** 8.84E-01** 3.40E+00** 2.20E+00**

6

2.

Average Diluted Concentration Released During Period Ci/ml 3.461E-06** 2.224E-06** 5.513E-07** 5.573E-07**

3.

Percent of Applicable Limit C. Dissolved and Entrained Noble Gases

1.

Total Releases Curies 7.603E-05 8

2.

Average Diluted Concentration Released During Period Ci/ml 1.233E-11

3.

Percent of Applicable Limit D. Gross Alpha Radioactivity

1.

Total Releases Curies 48

2.

Average Diluted Concentration Released During Period Ci/ml E. Volume of Liquid Waste to Discharge Canal (Prior to dilution)

Liters 3.808E+04 3.189E+04 9.200E+05 3.646E+05 3

F. Volume of Dilution Water for Period Liters 6.360E+08 3.975E+08 6.165E+09 3.946E+09 10 G. Total CCW Gigagal 2.74E+02 2.64E+02 2.65E+02 2.46e+02

  • - Not Detected.
    • - Includes activity from abnormal releases. Dilution flow was not determined for all abnormal releases.
      • - The applicable limit is expressed in terms of dose. See Radiological Impact Report.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT LIQUID EFFLUENTS E-18 TABLE 2B Page 1 of 2 Liquid Effluents Isotope in Curies (Required by Regulatory (REG) Guide 1.21)

Quarter 1 Quarter 2 Quarter 3 Quarter 4

1.

Ba-140

2.

Ce-144

3.

Co-58 1.15E-05 4.07E-06 4.22E-05 8.61E-05

4.

Co-60 2.37E-04 7.73E-05 1.61E-03 4.44E-03

5.

Cr-51

6.

Cs-134 2.00E-05 1.80E-04

7.

Cs-137 7.03E-05 6.38E-05 1.33E-03 1.37E-02

8.

Fe-55 8.49E-05 8.77E-05 4.65E-04 4.41E-04

9.

I-134

10.

La-140 11 Mo-99 3.27E-05 3.43E-06

12.

Mn-54 1.00E-04 5.54E-05 1.63E-04 3.54E-04

13.

Tc-99m 3.19E-05 3.35E-06

14.

Na-24 2.37E-03 9.79E-05

15.

Sb-124 1.01E-05

16.

Sr-89

17.

Sr-92

18.

Y-91m 2.09E-05

19.

Zn-65 9.49E-06 2.19E-05 9.35E-05

20.

Zn-69m

21.

Zr-97

22.

Xe-133

23.

Xe-133m

24.

Xe-135 7.60E-05

25.

I-131 1.05E-05

  • - Not Detected.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT LIQUID EFFLUENTS E-19 TABLE 2B Page 2 of 2 Liquid Effluents Isotope Others In Curies (Not Required by REG Guide 1.21)

Quarter 1 Quarter 2 Quarter 3 Quarter 4

1.

F-18 1.26E-06 7.94E-02

2.

Sb-122

3.

As-76 4.58E-04

4.

Be-7

5.

Sn-113

6.

La-141

7.

Tc-104

8.

Cs-139

9.

Ag-110m 9.25E-06 3.88E-06 2.91E-05 5.21E-06

10.

Nb-95

11.

Ru-103

12.

Sr-90 2.20E-07 2.37E-07 1.50E-05

13.

Sr-91

14.

Tc-101

15. Y-92 9.54E-06
16.

Nb-97 3.76E-06 3.21E-06

17.

Kr-87

18.

Cu-64 1.24E-05

19.

I-133 4.30E-05

20.

La-142

21.

Mn-56

22.

Ru-106 2.06E-05

  • - Not Detected.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT Solid Waste E-20 TABLE 3 Page 1 of 7 Solid Waste and Irradiated Fuel Shipments A. Solid Waste Shipped Offsite for Burial or Disposal (not Irradiated Fuel)

1. Type of Waste Unit Jan - Jun 2016 July-Dec 2016 Error %
a. Spent resins, filters, filter sludge, evaporator bottoms, etc.

m3 4.43E+01 5.63E+01

+/- 25%

Ci 1.57E+03 1.99E+03

+/-25%

b. Dry compressible waste, contaminated equipment, etc.

m3 1.31E+03 1.01E+03

+/- 25%

Ci 4.62E+04 3.56E+04

+/- 25%

c.

Irradiated Components, Control Rod blades & LPRMs with fission chambers m3 0.00E+00 0.00E+00

+/- 25%

Ci 0.00E+00 0.00E+00

+/- 25%

d.

Other - Combined Packages m3 0.00E+00 0.00E+00

+/- 25%

Ci 0.00E+00 0.00E+00

+/- 25%

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT Solid Waste E-21 TABLE 3 (Continued)

Page 2 of 7 Solid Waste and Irradiated Fuel Shipment

2. Estimate of Major Nuclide Composition
a. Spent resins, filters, filter sludge, evaporator bottoms, etc.

Nuclide Percentage Curies

1)

H-3 3.27E-02 4.99E-02

2)

C-14 3.55E-01 5.41E-01

3)

Cr-51 1.55E-01 2.37E-01

4)

Mn-54 4.13E+00 6.30E+00

5)

Fe-55 1.16E+01 1.77E+01

6)

Fe-59 2.00E-02 3.05E-02

7)

Co-58 7.67E-01 1.17E+00

8)

Co-60 6.38E+01 9.73E+01

9)

Ni-63 4.99E-01 7.62E-01

10)

Zn-65 2.86E+00 4.37E+00

11)

Sr-89 2.28E-02 3.48E-02

12)

Sr-90 3.62E-02 5.52E-02

13)

Zr-95 1.19E-03 1.82E-03

14)

Nb-95 2.30E-03 3.51E-03

15)

Tc-99 1.49E-02 2.28E-02

16)

Ag-110m 2.08E+00 3.18E+00

17)

Sb-124 3.04E-03 4.64E-03

18)

I-129 6.02E-04 9.19E-04

19)

I-131 5.70E-03 8.70E-03

20)

Cs-134 6.55E-01 9.99E-01

21)

Cs-137 1.27E+01 1.94E+01

22)

Ba-140 1.11E-02 1.69E-02

23)

La-140 2.44E-05 3.72E-05

24)

Ce-141 6.75E-03 1.03E-02

25)

Ce-144 2.56E-01 3.91E-01

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT Solid Waste E-22 TABLE 3 (Continued)

Page 3 of 7 Solid Waste and Irradiated Fuel Shipment

2. Estimate of Major Nuclide Composition (Continued)
a. Spent resins, filters, filter sludge, evaporator bottoms, etc. (Continued)

Nuclide Percentage Curies

26)

Au-199 3.54E-08 5.40E-08

27)

Pu-238 2.52E-06 3.84E-06

28)

Pu-239 1.02E-06 1.55E-06

29)

Pu-241 8.65E-03 1.32E-02

30)

Am-241 1.53E-04 2.33E-04

31)

Cm-242 3.36E-05 5.13E-05

32)

Cm-243 7.93E-05 1.21E-04

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT Solid Waste E-23 TABLE 3 (Continued)

Page 4 of 7 Solid Waste and Irradiated Fuel Shipments

2. Estimate of Major Nuclide Composition (Continued)
b. Dry, Compressible Waste, Contaminated Equipment, etc.

Nuclide Percentage Curies

1)

H-3 3.49E-02 1.37E-03

2)

C-14 4.67E-03 1.83E-04

3)

Cr-51 8.34E-01 3.27E-02

4)

Mn-54 2.65E+00 1.04E-01

5)

Fe-55 2.34E+01 9.19E-01

6)

Fe-59 8.82E-02 3.46E-03

7)

Co-58 6.40E-01 2.51E-02

8)

Co-60 6.09E+01 2.39E+00

9)

Ni-63 9.76E-01 3.83E-02

10)

Zn-65 1.96E+00 7.68E-02

11)

Sr-90 3.65E-02 1.43E-03

12)

Zr-95 0.00E+00 0.00E+00

13)

Nb-95 4.87E-02 1.91E-03

14)

Tc-99 3.03E-02 1.19E-03

15)

Ag-110m 1.98E+00 7.75E-02

16)

Sb-124 0.00E+00 0.00E+00

17)

I-129 3.16E-03 1.24E-04

18)

Cs-134 5.15E-01 2.02E-02

19)

Cs-137 5.68E+00 2.23E-01

20)

Ce-144 1.47E-01 5.76E-03

21)

Pu-238 2.40E-04 9.43E-06

22)

Pu-239 1.23E-04 4.81E-06

23)

Pu-241 1.35E-02 5.29E-04

24)

Am-241 2.70E-03 1.06E-04

25)

Cm-244 6.25E-04 2.45E-05

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT Solid Waste E-24 TABLE 3 (Continued)

Page 5 of 7 Solid Waste and Irradiated Fuel Shipments

2. Estimate of Major Nuclide Composition (Continued)
c. Irradiated Components, Control Rods, LPRMs with fission chambers Nuclide Percentage Curies None

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT Solid Waste E-25 TABLE 3 (Continued)

Page 6 of 7 Solid Waste and Irradiated Fuel Shipments

2. Estimate of Major Nuclide Composition (Continued) d Other (Combined Packages)

Nuclide Percentage Curies None

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT Solid Waste E-26 TABLE 3 (Continued)

Page 7 of 7 Solid Waste and Irradiated Fuel Shipments

3. Solid Waste Disposition Number of Shipments Mode of Transportation Destination 3

Hittman Alaron Corporation 47 Hittman Energy Solutions Inc.

50 Interstate Ventures, Inc.

Toxco, Inc 2

TVA Transportation Services Toxco, Inc 29 Hittman Waste Control Specialist 18 Interstate Ventures, Inc.

Waste Control Specialist B. Irradiated Fuel Shipments Number of Shipments Mode of Transportation Destination 0

0 0

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT RADIOLOGICAL IMPACT E-27

1. Introduction Potential doses to the "maximum exposed individual" and the population around Browns Ferry Nuclear Plant (BFN) are calculated for each quarter as required in Section 5.2 of the Offsite Dose Calculation Manual (ODCM). The methodology used to estimate dose for determining plant releases for the reporting period is specified in Sections 6 and 7 of the ODCM. Dispersion of radioactive effluents in the environment is estimated using meteorological data and river flow measured during the period. In this report, the doses resulting from releases are described and compared to limits established for BFN.
2. Dose Limits The ODCM specifies limits for the release of radioactive effluents, as well as limits for doses to the general public from the release of radioactive effluents. These limits are set well below the Technical Specification limits which govern the concentrations of radioactivity and doses permissible in unrestricted areas. This ensures that radioactive effluent releases are As Low As Reasonably Achievable.

The air dose limits in areas at and beyond the Site Boundary due to noble gases released in gaseous effluents per unit are:

5 mrad per quarter and 10 mrad per year for gamma radiation.

- and -

10 mrad per quarter and 20 mrad per year for beta radiation.

The dose limits to a member of the public in an unrestricted area from radioiodines, radioactive materials in particulate form, and radionuclides other than noble gases with half-lives > 8 days released in gaseous effluents for each unit are:

7.5 mrem per quarter and 15 mrem per year to any organ.

The dose or dose commitment to a member of the public from radioactive material in liquid effluents released to unrestricted areas are:

1.5 mrem per quarter and 3 mrem per year to the total body,

- and -

5 mrem per quarter and 10 mrem per year to any organ.

The limit for the total effective dose equivalent to an individual member of the public inside the site boundary is:

100 mrem per year.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT RADIOLOGICAL IMPACT E-28

2. Dose Limits (Continued)

The Environmental Protection Agency limits for total dose to any member of the public in the vicinity of a nuclear power plant, established in the Environmental Dose Standard of 40 CFR 190, are:

25 mrem per year to the whole body, 75 mrem per year to the thyroid,

- and -

25 mrem per year to any other organ.

3. Dose Calculations Estimated doses to members of the public are determined using computer models (the Gaseous Effluent Licensing Code, and the Quarterly Water Dose Assessment Code (QWATA)).

These models are based on guidance provided by the Nuclear Regulatory Commission (NRC) for determining the potential dose to individuals and populations living in the vicinity of the plant.

The area around the plant is analyzed to determine the pathways through which the public may receive a dose. The doses calculated are a representation of the dose to a "maximum exposed individual." Some of the factors used in these calculations (such as ingestion rates) are maximum values to ensure conservative reporting data. The values chosen will tend to overestimate the dose. The expected dose to actual individuals is lower. The calculated doses are presented in Tables 4, 5, and 6.

4. Doses From Airborne Effluents For airborne effluents, members of the public can be exposed to radiation from several sources:

direct radiation from the radioactivity in the air, direct radiation from radioactivity deposited on the ground, inhalation of airborne radioactivity, ingestion of vegetation which contains radioactivity deposited from the atmosphere, and ingestion of milk and beef which contains radioactivity deposited from the atmosphere onto vegetation and subsequently consumed by animals.

a. Airborne Release Points There are four monitored release points from BFN: the turbine building, the radwaste building, the reactor building, and the stack.

Releases from the turbine building are considered ground-level releases. The ground-level Joint Frequency Distribution (JFD) is derived from wind speeds and directions measured 10.5 meters above the ground and from the vertical temperature difference between 10.03 and 45.30 meters, and are presented for each quarter in the 2016 Meteorological Data Tables 7A, 7B, 7C, and 7D.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT RADIOLOGICAL IMPACT E-29

4. Doses From Airborne Effluents (Continued)
a. Airborne Release Points (Continued)

Releases from the radwaste and reactor buildings are considered split-level releases.

Portions of the release are treated as ground-level while other portions are considered elevated depending on the ratio of the vertical exit velocity to the horizontal wind speed.

The split-level dispersion approach is implemented using a model that requires two complete quarterly JFDs for each effluent vent, one for the ground-level releases and one for the elevated releases. The ground-level portion of the split-level JFD is based on wind speeds and directions measured 10.5 meters above ground-level and from the vertical temperature difference between 10.03 and 45.30 meters. The elevated portion of the split-level JFD is based on wind speeds and direction measurements at the 45.74 meter level and the vertical temperature difference between 10.03 and 89.59 meters. Both of these JFDs are given for each quarter in the 2016 Meteorological Data Tables 8A, 8B, 8C, and 8D.

Releases from the stack are considered to be elevated releases. The JFDs for elevated releases are based on wind directions and wind speeds measured at 90.29 meters and the vertical temperature difference between 10.03 and 89.59 meters, and are given for each quarter in the 2016 Meteorological Data Tables 9A, 9B, 9C, 9D.

b. Meteorological Data Meteorological variables at BFN are measured continuously. Measurements collected include wind speed and wind direction at heights of 10.5, 45.74, and 90.29 meters above the ground, and temperature at heights of 10.03, 45.30, and 89.59 meters above the ground. Quarterly JFDs are calculated for each release point using the appropriate levels of meteorological data. A quarterly JFD gives the percentage of the time that the wind is blowing out of a particular upwind compass sector in a particular range of wind speeds for a given stability class A through G. The wind speeds are divided into nine wind speed ranges. Calms are distributed by direction in proportion to the distribution of noncalm wind directions less than 1.6 m/s (3.5 mph). Stability classes are determined from the vertical temperature difference between two measurement levels.

The generally open terrain around BFN does not cause any significant effects on the transport and dispersion of gaseous effluents from the plant. Within 30 kilometers of BFN, the terrain is mostly gently rolling hills (30-60 meters). Between 30 and 80 kilometers, the hills become larger to the north and south and mountainous to the east and northeast. The Tennessee River/Wheeler Lake may have a minor effect on transport and dispersion in the immediate vicinity of BFN during periods of winds with a southerly component, overcast skies, and relatively high wind speeds. Also, the lower layer (10-45 meters) stability class tends to be more stable. However, during this infrequent condition, dose estimates will be conservative.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT RADIOLOGICAL IMPACT E-30

4. Doses From Airborne Effluents (Continued)
c. External Exposure Dose Dose calculated for maximum external air dose (gamma-air and beta-air) are made for points at and beyond the unrestricted area boundary as described in the BFN ODCM. The highest of these doses is then selected.
d. Submersion Dose External doses to the skin and total body, due to submersion in a cloud of noble gases, are calculated for the nearest residence in each sector. The residence with the highest dose is then selected from all sectors.
e. Organ Dose Dose to an organ due to releases of airborne effluents are estimated for the inhalation, ground contamination, and ingestion pathways. The ingestion pathway is further divided into three possible contributing pathways: ingestion of cow/goat milk, ingestion of beef, and ingestion of vegetables. Doses from applicable pathways are calculated for each receptor location identified in the most recent land use survey. To determine the maximum organ dose, the doses from the pathways are summed for each receptor. However, for the ingestion dose, only those pathways that exist for each receptor are considered in the sum, e.g., milk ingestion doses are included only for locations where milk was consumed without commercial preparation and vegetable ingestion is included only for those locations where a garden was identified. To conservatively account for beef ingestion, a beef ingestion dose equal to that for the highest unrestricted area boundary location is added to each identified receptor. For ground contamination, the dose added to the organ dose being calculated is the total body dose calculated for that location, i.e., it is assumed that the dose to an individual organ is equal to the total body dose.

The maximum organ dose, thyroid dose, and total body dose from airborne effluents are presented in Table 4.

5. Doses From Liquid Effluents For liquid effluents, the public can be exposed to radiation from three sources: the ingestion of water from the Tennessee River, the ingestion of fish caught in the Tennessee River, and direct exposure from radioactive material deposited on the river shoreline sediment (recreation).

The concentration of radionuclides in the Tennessee River is calculated by a computer model which uses measured hydraulic data downstream of BFN. Parameters used to determine the doses are based on guidance given by the NRC for maximum ingestion rates, exposure times, etc.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT RADIOLOGICAL IMPACT E-31

5. Doses From Liquid Effluents (Continued)

Wherever possible, parameters used in the dose calculation are site specific. The models that are used to estimate doses, as well as the parameters input to the models, are described in detail in the BFN ODCM.

a. Liquid Release Points and River Data Radionuclide concentrations in the Tennessee River are calculated assuming that releases in liquid effluents are continuous. When necessary, liquid releases from BFN, located at Tennessee River Mile 294, are made through diffusers which extend into the Tennessee River. It is assumed that releases to the river through these diffusers will initially be entrained in one-fifth of the water which flows past the plant. The QWATA code makes the assumption that this mixing condition holds true until the water is completely mixed at the first downstream dam (Wheeler Dam), at Tennessee River Mile 283.

Doses are calculated for locations within a 50 mile radius downstream of the plant site. The maximum potential recreation dose is calculated for a location immediately downstream from the plant's release point. The maximum exposed individual dose from ingestion of fish is assumed to be that calculated for the consumption of fish caught anywhere between the plant and the first downstream dam. The maximum exposed individual dose from drinking water is assumed to be that calculated at the nearest downstream public water supply

[West Morgan - East Lawrence (WMEL)]. This could be interpreted as indicating that the maximum exposed individual, as assumed for liquid releases from BFN, is an individual who obtains all of his drinking water at WMEL, consumes fish caught from the Tennessee River between BFN and Wheeler Dam, and spends 500 hours0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> per year on the shoreline just downstream of the plant's release point. Doses calculated for the maximum exposed individual due to liquid effluents for each quarter in the period are presented in Table 5 along with the average river flows past the plant site for the periods.

6. Population Doses Population doses due to airborne effluents are calculated for people living within a 50-mile radius of the plant site. Doses from external pathways and inhalation are based on the 50-mile human population distribution. Ingestion population doses are calculated assuming that each individual consumed milk, vegetables, and meat produced within the sector in which the individual resides.

Population doses due to liquid effluents are calculated for the entire downstream Tennessee River population. Water ingestion population doses are calculated using actual population figures for downstream public water supplies. Fish ingestion population doses are calculated assuming that all sport fish caught in the Tennessee River are consumed by the Tennessee River population. Recreation population doses are calculated using historical recreational data on the number of shoreline visits at downstream locations.

Population doses calculated for airborne and liquid effluents are presented in Tables 4 and 5.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT RADIOLOGICAL IMPACT E-32

7. Offsite Direct Radiation Dose External gamma radiation levels were measured by environmental dosimeters deployed around BFN as part of the offsite Radiological Environmental Monitoring Program (REMP).

The quarterly gamma radiation levels determined from these dosimeters during this reporting period averaged approximately 18 mrem/quarter at onsite (at or near the site boundary) stations and approximately 15 mrem/quarter at offsite stations or approximately 2.5 mrem/quarter higher onsite than at offsite stations. This difference is consistent with levels measured for pre-operation and construction phases of the Tennessee Valley Authority nuclear plants where the average radiation levels onsite were generally 2-6 mrem/quarter higher than the levels offsite. This may be attributable to natural variations in environmental radiation levels, earth moving activities onsite, the mass of concrete employed in the construction of the plants, or other undetermined influences.

Fluctuations in natural background dose rates and in dosimeter readings tend to mask any small increments which may be due to plant operations. Thus, there was no identifiable increase in dose rate levels attributable to direct radiation from plant equipment and/or gaseous effluents.

8. Dose To A Member Of The Public Inside The Site Boundary Pursuant to ODCM Section 7.7.5, a review was performed to determine the highest dose to a member of the public in the site boundary. The dose to a member of the public consists of the sum of dose commitments from effluent releases as well as any direct radiation dose.

The gaseous effluent dose commitment is negligible compared to the direct radiation dose.

The direct radiation dose was determined from area environmental dosimeters located onsite. It consisted of gamma dose from the plume, ground contamination, and from equipment sources (i.e., tanks, turbine shine, radioactive material storage areas, etc.). The critical location was determined to be an Optically Stimulated Luminescence (OSL) dosimeter near the Livewell Center (Training Center). The direct radiation dose accounting for background and occupancy was approximately 0.75 mrem/quarter during 2016.

The total annual dose commitment to a member of the public for 2016 was 3 mrem. It can be concluded that the dose limit for a member of the public at the site boundary as specified in 10 CFR 20.1301 was not exceeded.

9. Total Dose To determine compliance with 40 CFR 190, annual total dose contributions to the maximum exposed individual from BFN radioactive effluents and all other nearby uranium fuel cycle sources are considered.

The annual dose to any organ other than the thyroid for the maximum exposed individual is conservatively calculated by summing the following doses: the total body air submersion dose for each quarter, the critical organ dose (for any organ other than the thyroid) from airborne effluents for each quarter from ground contamination, inhalation and ingestion, the total body dose from liquid effluents for each quarter, the maximum organ dose (for any organ other than the thyroid) from liquid effluents for each quarter, and any identifiable increase in direct

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT RADIOLOGICAL IMPACT E-33

9. Total Dose (continued) radiation dose levels as measured by the REMP. This dose is compared to the 40 CFR 190 limit for total body or any organ dose (other than the thyroid) to determine compliance.

The annual thyroid dose to the maximum exposed individual is conservatively estimated by summing the following doses: the total body air submersion dose for each quarter, the thyroid dose from airborne effluents for each quarter, the total body dose from liquid effluents for each quarter, the thyroid dose from liquid effluents for each quarter, and any identifiable increase in direct radiation dose levels as measured by the REMP. This dose is compared to the 40 CFR 190 limit for thyroid dose to determine compliance.

Total dose from the fuel cycle is presented in Table 6.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT RADIOLOGICAL IMPACT E-34 TABLE 4 Page 1 of 4 Doses from Airborne Effluents First Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air 3.66E-11 mrad 5 mrad

< 1 %

NNW/1650 meters Beta Air 1.12E-10 mrad 10 mrad

< 1 %

NNW/1650 meters Submersion Total Body 1.40E-03 mrem NA NA ESE/1750 meters Skin 1.65E-03 mrem NA NA ESE/1750 meters Organ Doses Child/Bone 5.90E-02 mrem 7.5 mrem

< 1 %

NNW/2290 meters Child/Thyroid 5.69E-02 mrem 7.5 mrem

< 1 %

NNW/2290 meters Child/Total Body 5.63E-02 mrem 7.5 mrem

< 1 %

NNW/2290 meters Population Doses Total Body Dose 2.17E-01 man-rem Maximum Organ Dose (organ) 5.65E-01 man-rem (Bone)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT RADIOLOGICAL IMPACT E-35 TABLE 4 (Continued)

Page 2 of 4 Doses from Airborne Effluents Second Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air 9.12E-12 mrad 5 mrad

< 1 %

N/1525 meters Beta Air 2.79e-11 mrad 10 mrad

< 1 %

N/1525 meters Submersion Total Body 3.11E-03 mrad NA NA E/1410 meters Skin 3.66E-03 mrad NA NA E/1410 meters Organ Doses Child/Bone 3.55E-02 7.5 mrem

< 1 %

N/2540 meters Child/Thyroid 1.79E-02 mrem 7.5 mrem

< 1 %

N/2540 meters Child/Total Body 1.81E-02 mrem 7.5 mrem

< 1 %

N/2540 meters Population Doses Total Body Dose 1.81E-01 man-rem Maximum Organ Dose (organ) 6.49E-01 man-rem (bone)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT RADIOLOGICAL IMPACT E-36 TABLE 4 (Continued)

Page 3 of 4 Doses from Airborne Effluents Third Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air 7.37E-12 mrad 5 mrad

< 1 %

S/2250 meters Beta Air 2.25E-11 mrad 10 mrad

< 1 %

S/2250 meters Submersion Total Body 1.58E-03 mrad NA NA NNW/1650 meters Skin 1.86E-03 mrad NA NA NNW/1650 meters Organ Doses Child/Bone 3.54E-02 7.5 mrem

< 1 %

NE/3790 meters Child/Thyroid 1.19E-02 7.5 mrem

< 1 %

N/2540 meters Child/Total Body 1.16E-02 7.5 mrem

< 1 %

N/2540 meters Population Doses Total Body Dose 1.60E-01 man-rem Maximum Organ Dose (organ) 7.02E-01 man-rem (bone)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT RADIOLOGICAL IMPACT E-37 TABLE 4 (Continued)

Page 4 of 4 Doses from Airborne Effluents Fourth Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air 1.40E-11 mrad 5 mrad

< 1 %

NNW/1650 meters Beta Air 4.27E-11 mrad 10 mrad

< 1 %

NNW/1650 meters Submersion Total Body 8.31E-04 mrad NA NA NNW/1650 meters Skin 9.78E-04 mrad NA NA NNW/1650 meters Organ Doses Child/ Bone 2.48E-02 7.5 mrem

< 1 %

NNW/3590 meters Child/Thyroid 2.01E-02 mrem 7.5 mrem

< 1 %

N/2540 meters Child /Total Body 2.00E-02 mrem 7.5 mrem

< 1 %

N/2540 meters Population Doses Total Body Dose 1.69E-01 man-rem Maximum Organ Dose (organ) 4.87E-01 man-rem (bone)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT RADIOLOGICAL IMPACT E-38 Table 5 Page 1 of 4 Doses from Liquid Effluents First Quarter*

Individual Doses (mrem)

Age Group Organ Dose Pathway Dose Quarterly Limit Percent of Limit Child Total Body Fish Ingestion 2.1e-06 Recreation 5.0E-06 Water Ingestion 9.6E-06 Total 1.7E-05 1.5 mrem

< 1 %

Teen Liver Fish Ingestion 1.4E-05 Recreation 5.0E-06 Water Ingestion 5.2E-06 Total 2.4E-05 5 mrem

< 1 %

Child Thyroid Fish Ingestion 1.2E-07 Recreation 5.0E-06 Water Ingestion 9.4E-06 Total 1.5E-05 5 mrem

< 1 %

Average Riverflow past BFN (cubic feet per second): 90195 Population Doses Total Body Dose 7.2E-04 man-rem Maximum Organ Dose (organ) 7.7E-04 man-rem (liver)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

  • Includes dose from abnormal releases.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT RADIOLOGICAL IMPACT E-39 Table 5 (Continued)

Page 2 of 4 Doses from Liquid Effluents Second Quarter*

Individual Doses (mrem)

Age Group Organ Dose Pathway Dose Quarterly Limit Percent of Limit Adult Total Body Fish Ingestion 6.2E-05 Recreation 1.6E-05 Water Ingestion 2.4E-05 Total 1.0E-04 1.5 mrem

< 1 %

Teen Liver Fish Ingestion 9.8E-05 Recreation 1.6E-05 Water Ingestion 1.8E-05 Total 1.3E-04 5 mrem

< 1 %

Child Thyroid Fish Ingestion 3.7E-07 Recreation 1.6E-05 Water Ingestion 3.0E-05 Total 4.6E-05 5 mrem

< 1 %

Average Riverflow past BFN (cubic feet per second): 11354 Population Doses Total Body Dose 2.3E-03 man-rem Maximum Organ Dose (organ) 2.7E-03 man-rem (liver)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

  • Includes dose from abnormal releases.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT RADIOLOGICAL IMPACT E-40 Table 5 (Continued)

Page 3 of 4 Doses from Liquid Effluents Third Quarter*

Individual Doses (mrem)

Age Group Organ Dose Pathway Dose Quarterly Limit Percent of Limit Adult Total Body Fish Ingestion 9.8E-04 Recreation 2.4E-04 Water Ingestion 8.3E-05 Total 1.3E-03 1.5 mrem 1 %

Adult Liver Fish Ingestion 1.5E-03 Recreation 2.4E-04 Water Ingestion 9.2E-05 Total 1.8E-03 5 mrem

< 1 %

Child Thyroid Fish Ingestion 3.0E-06 Recreation 2.4E-04 Water Ingestion 9.1E-05 Total 3.3E-04 5 mrem

< 1 %

Average Riverflow past BFN (cubic feet per second): 15271 Population Doses Total Body Dose 3.2E-02 man-rem Maximum Organ Dose (organ) 3.7E-02 man-rem (liver)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

  • Includes dose from abnormal releases.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT RADIOLOGICAL IMPACT E-41 Table 5 (Continued)

Page 4 of 4 Doses from Liquid Effluents Fourth Quarter*

Individual Doses (mrem)

Age Group Organ Dose Pathway Dose Quarterly Limit Percent of Limit Adult Total Body Fish Ingestion 8.8E-03 Recreation 1.0E-03 Water Ingestion 2.0E-04 Total 1.0E-02 1.5 mrem

< 1 %

Teen Liver Fish Ingestion 1.4E-02 Recreation 1.0E-03 Water Ingestion 2.6E-04 Total 1.5E-02 5 mrem

< 1 %

Child Thyroid Fish Ingestion 6.1E-07 Recreation 1.0E-03 Water Ingestion 5.0E-05 Total 1.1E-03 5 mrem

< 1 %

Average Riverflow past BFN (cubic feet per second): 17169 Population Doses Total Body Dose 1.6E-01 man-rem Maximum Organ Dose (organ) 2.1E-01 man-rem (liver)

Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).

  • Includes dose from abnormal releases.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT RADIOLOGICAL IMPACT E-42 Table 5A Page 1 of 1 Total Dose from I-131 Water Ingestion Pathway Quarter 1

2 3

4 Totals I-131 Ci 0

0 1.05E-05 0

1.05E-05 Infant/Thyroid (mrem) 0 0

6.7E-06 0

6.7E-06 Population/Thyroid (mrem) 0 0

4.1E-05 0

4.1E-05 Doses from I-131 Water Ingestion Pathway The REMP requirements as specified in Table 3.12-1 from NUREG 1302, Offsite Dose Calculation Manual Guidance: Standard Radiological Effluent Controls for Boiling Water Reactors, dated April 1991, requires an I-131 specific analysis for drinking water pathway samples if the annual dose from I-131 is greater than 1 mrem. In order to evaluate the need for implementation of this additional analysis, the drinking water pathway dose from I-131 to the maximum organ and age group was calculated. There was no drinking water pathway dose from I-131 and the performance of the I-131 specific analysis is not required for BFN REMP drinking water samples.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT RADIOLOGICAL IMPACT E-43 Table 6 Page 1 of 1 Total Dose from Fuel Cycle Dose First Quarter Second Quarter Third Quarter Fourth Quarter Total Body or any Organ (except thyroid)

Total body air submersion 1.40E-03 3.11E-03 1.58E-03 8.31E-04 Critical organ dose (air) 5.9E-02 3.55E-02 3.54E-02 2.48E-02 Total body dose (liquid) 1.7E-05 1.0E-04 1.3E-03 1.0E-02 Maximum organ dose (liquid) 2.4E-05 1.3E-04 1.8E-03 1.5E-02 Direct Radiation Dose 0.0E+00 0.0E+00 0.0E+00 0.0E+00 Total 6.04E-02 3.88E-02 4.01E-02 5.06E-02 Cumulative Total Dose (mrem)

(Total body or any other organ) 1.90E-01 Annual Dose Limit (mrem) 2.5E+01 Percent of Limit

< 1%

Thyroid Dose (mrem)

Total body air submersion 1.40E-03 3.11E-03 1.58E-03 8.31E-04 Thyroid dose (airborne) 5.69E-02 1.79E-02 1.19E-02 2.01E-02 Total body dose (liquid) 1.7E-05 1.0E-04 1.3E-03 1.0E-02 Thyroid dose (liquid) 1.5E-05 4.6E-05 3.3E-04 1.1E-03 Direct Radiation Dose 0.0E+00 0.0E+00 0.0E+00 0.0E+00 Total 5.83E-02 2.12E-02 1.51E-02 3.20E-02 Cumulative Total Dose (Thyroid) mrem 1.27E-01 Annual Dose Limit (mrem) 7.5E+01 Percent of Limit

< 1%

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-44 BROWNS FERRY NUCLEAR PLANT 2016 METEOROLOGICAL DATA TABLE 7A JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES FIRST QUARTER

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-45 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.185 0.000 0.000 0.000 0.185 NNE 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 E 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 ESE 0.000 0.000 0.000 0.139 0.046 0.000 0.000 0.000 0.000 0.185 SE 0.000 0.000 0.046 0.231 0.000 0.000 0.000 0.000 0.000 0.278 SSE 0.000 0.000 0.231 0.556 0.000 0.000 0.000 0.000 0.000 0.787 S 0.000 0.000 0.278 0.231 0.417 0.046 0.000 0.000 0.000 0.972 SSW 0.000 0.000 0.093 0.417 0.093 0.000 0.000 0.000 0.000 0.602 SW 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.093 WSW 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.093 W 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 NNW 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 SUBTOTAL 0.000 0.000 0.694 1.759 0.602 0.417 0.000 0.000 0.000 3.472 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2160 TOTAL HOURS OF STABILITY CLASS A 75 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A 75 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2160 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2016/05/06 MEAN WIND SPEED = 4.98 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-46 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.231 0.000 0.000 0.000 0.231 NNE 0.000 0.000 0.000 0.000 0.046 0.093 0.000 0.000 0.000 0.139 NE 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.093 ENE 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.093 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.093 SE 0.000 0.000 0.046 0.093 0.046 0.000 0.000 0.000 0.000 0.185 SSE 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.093 S 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 SSW 0.000 0.000 0.046 0.093 0.046 0.000 0.000 0.000 0.000 0.185 SW 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 WSW 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 W 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.093 WNW 0.000 0.000 0.000 0.000 0.000 0.139 0.278 0.000 0.000 0.417 NW 0.000 0.000 0.000 0.000 0.000 0.139 0.139 0.000 0.000 0.278 NNW 0.000 0.000 0.000 0.000 0.000 0.046 0.139 0.000 0.000 0.185 SUBTOTAL 0.000 0.000 0.185 0.324 0.417 0.741 0.556 0.000 0.000 2.222 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2160 TOTAL HOURS OF STABILITY CLASS B 48 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B 48 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2160 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2016/05/06 MEAN WIND SPEED = 8.84 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-47 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.046 0.046 0.093 0.000 0.000 0.000 0.185 NNE 0.000 0.000 0.000 0.000 0.093 0.046 0.000 0.000 0.000 0.139 NE 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 ENE 0.000 0.000 0.000 0.000 0.139 0.046 0.000 0.000 0.000 0.185 E 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.093 ESE 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.093 SE 0.000 0.000 0.139 0.093 0.046 0.000 0.000 0.000 0.000 0.278 SSE 0.000 0.000 0.093 0.046 0.000 0.000 0.000 0.000 0.000 0.139 S 0.000 0.000 0.185 0.000 0.046 0.000 0.000 0.000 0.000 0.231 SSW 0.000 0.000 0.046 0.093 0.000 0.000 0.000 0.000 0.000 0.139 SW 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.093 WSW 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.093 W 0.000 0.000 0.000 0.000 0.093 0.093 0.000 0.000 0.000 0.185 WNW 0.000 0.000 0.000 0.000 0.093 0.370 0.417 0.000 0.000 0.880 NW 0.000 0.000 0.000 0.000 0.046 0.324 0.139 0.000 0.000 0.509 NNW 0.000 0.000 0.000 0.000 0.093 0.231 0.000 0.000 0.000 0.324 SUBTOTAL 0.000 0.000 0.602 0.370 0.787 1.296 0.556 0.000 0.000 3.611 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2160 TOTAL HOURS OF STABILITY CLASS C 78 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 78 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2160 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2016/05/06 MEAN WIND SPEED = 8.15 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-48 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.185 0.602 0.741 0.370 0.000 0.000 0.000 1.898 NNE 0.000 0.000 0.231 1.019 0.463 0.370 0.000 0.000 0.000 2.083 NE 0.000 0.000 0.278 0.509 0.417 0.139 0.000 0.000 0.000 1.343 ENE 0.000 0.000 0.602 0.833 0.370 0.000 0.000 0.000 0.000 1.806 E 0.000 0.000 0.185 0.278 0.093 0.000 0.000 0.000 0.000 0.556 ESE 0.000 0.000 0.185 0.509 0.278 0.000 0.000 0.000 0.000 0.972 SE 0.000 0.046 0.556 0.556 0.139 0.000 0.000 0.000 0.000 1.296 SSE 0.000 0.000 0.648 0.417 0.000 0.000 0.000 0.000 0.000 1.065 S 0.000 0.000 0.694 0.556 0.417 0.046 0.000 0.000 0.000 1.713 SSW 0.000 0.000 0.185 0.093 0.417 0.000 0.000 0.000 0.000 0.694 SW 0.000 0.000 0.278 0.278 0.046 0.000 0.000 0.000 0.000 0.602 WSW 0.000 0.000 0.278 0.556 0.093 0.139 0.000 0.000 0.000 1.065 W 0.000 0.000 0.278 0.833 0.556 0.741 0.093 0.000 0.000 2.500 WNW 0.000 0.000 0.185 0.509 0.880 1.759 1.713 0.093 0.000 5.139 NW 0.000 0.000 0.185 0.278 0.833 3.287 1.667 0.000 0.000 6.250 NNW 0.000 0.000 0.602 0.417 1.574 1.898 0.880 0.000 0.000 5.370 SUBTOTAL 0.000 0.046 5.556 8.241 7.315 8.750 4.352 0.093 0.000 34.352 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2160 TOTAL HOURS OF STABILITY CLASS D 742 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D 742 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2160 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2016/05/06 MEAN WIND SPEED = 7.28 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-49 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.139 0.648 0.231 0.231 0.139 0.000 0.000 0.000 1.389 NNE 0.000 0.046 0.556 0.417 0.417 0.185 0.000 0.000 0.000 1.620 NE 0.000 0.046 0.556 0.509 0.417 0.324 0.000 0.000 0.000 1.852 ENE 0.000 0.185 0.556 0.370 0.093 0.046 0.046 0.000 0.000 1.296 E 0.000 0.093 1.296 0.231 0.046 0.000 0.000 0.000 0.000 1.667 ESE 0.000 0.000 0.556 0.926 0.231 0.231 0.000 0.000 0.000 1.944 SE 0.000 0.185 0.880 1.065 0.093 0.000 0.000 0.000 0.000 2.222 SSE 0.000 0.139 1.435 0.694 0.046 0.000 0.000 0.000 0.000 2.315 S 0.000 0.046 1.574 1.667 0.833 0.463 0.000 0.000 0.000 4.583 SSW 0.000 0.185 0.694 0.324 0.463 0.185 0.000 0.000 0.000 1.852 SW 0.000 0.093 0.648 0.231 0.046 0.093 0.000 0.000 0.000 1.111 WSW 0.000 0.093 0.509 0.556 0.046 0.000 0.000 0.000 0.000 1.204 W 0.000 0.139 0.648 0.694 0.231 0.139 0.000 0.000 0.000 1.852 WNW 0.000 0.046 0.231 0.000 0.185 0.231 0.000 0.000 0.000 0.694 NW 0.000 0.093 0.231 0.463 1.019 0.741 0.046 0.000 0.000 2.593 NNW 0.000 0.046 0.648 0.741 1.528 0.556 0.000 0.000 0.000 3.519 SUBTOTAL 0.000 1.574 11.667 9.120 5.926 3.333 0.093 0.000 0.000 31.713 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2160 TOTAL HOURS OF STABILITY CLASS E 685 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E 685 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2160 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2016/05/06 MEAN WIND SPEED = 4.35 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-50 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.093 0.880 0.324 0.000 0.000 0.000 0.000 0.000 1.296 NNE 0.000 0.046 0.556 0.417 0.046 0.000 0.000 0.000 0.000 1.065 NE 0.000 0.231 0.093 0.046 0.000 0.000 0.000 0.000 0.000 0.370 ENE 0.000 0.093 0.185 0.093 0.000 0.000 0.000 0.000 0.000 0.370 E 0.000 0.000 0.324 0.185 0.000 0.000 0.000 0.000 0.000 0.509 ESE 0.000 0.139 0.278 0.139 0.000 0.000 0.000 0.000 0.000 0.556 SE 0.000 0.139 1.296 0.463 0.046 0.000 0.000 0.000 0.000 1.944 SSE 0.000 0.278 2.037 0.463 0.046 0.000 0.000 0.000 0.000 2.824 S 0.000 0.185 1.250 1.991 1.250 0.046 0.000 0.000 0.000 4.722 SSW 0.000 0.000 0.370 0.139 0.278 0.046 0.000 0.000 0.000 0.833 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 WNW 0.000 0.185 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.231 NW 0.000 0.046 0.231 0.185 0.000 0.000 0.000 0.000 0.000 0.463 NNW 0.000 0.093 0.417 0.278 0.093 0.046 0.000 0.000 0.000 0.926 SUBTOTAL 0.000 1.574 7.963 4.722 1.759 0.139 0.000 0.000 0.000 16.157 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2160 TOTAL HOURS OF STABILITY CLASS F 349 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F 349 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2160 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2016/05/06 MEAN WIND SPEED = 3.35 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-51 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.278 0.463 0.139 0.000 0.000 0.000 0.000 0.000 0.880 NNE 0.000 0.278 0.093 0.139 0.000 0.000 0.000 0.000 0.000 0.509 NE 0.000 0.139 0.139 0.000 0.000 0.000 0.000 0.000 0.000 0.278 ENE 0.000 0.000 0.139 0.000 0.000 0.000 0.000 0.000 0.000 0.139 E 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.093 ESE 0.000 0.093 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.185 SE 0.000 0.000 0.231 0.139 0.000 0.000 0.000 0.000 0.000 0.370 SSE 0.000 0.324 2.269 0.648 0.000 0.000 0.000 0.000 0.000 3.241 S 0.000 0.046 1.065 0.556 0.231 0.000 0.000 0.000 0.000 1.898 SSW 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 NW 0.000 0.093 0.139 0.046 0.000 0.000 0.000 0.000 0.000 0.278 NNW 0.000 0.185 0.231 0.000 0.000 0.000 0.000 0.000 0.000 0.417 SUBTOTAL 0.000 1.667 4.907 1.667 0.231 0.000 0.000 0.000 0.000 8.472 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2160 TOTAL HOURS OF STABILITY CLASS G 183 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G 183 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2160 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2016/05/06 MEAN WIND SPEED = 2.59 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-52 BROWNS FERRY NUCLEAR PLANT 2016 METEOROLOGICAL DATA TABLE 7B JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES SECOND QUARTER

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-53 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.092 0.321 0.000 0.000 0.000 0.413 NNE 0.000 0.000 0.000 0.000 0.092 0.275 0.000 0.000 0.000 0.367 NE 0.000 0.000 0.000 0.000 0.046 0.138 0.000 0.000 0.000 0.184 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.092 0.184 0.643 0.000 0.000 0.000 0.000 0.918 SE 0.000 0.000 0.505 1.194 0.321 0.000 0.000 0.000 0.000 2.020 SSE 0.000 0.000 0.918 0.643 0.000 0.000 0.000 0.000 0.000 1.561 S 0.000 0.000 1.286 0.689 0.046 0.000 0.000 0.000 0.000 2.020 SSW 0.000 0.000 0.505 0.781 0.000 0.000 0.000 0.000 0.000 1.286 SW 0.000 0.000 0.046 0.413 0.000 0.000 0.000 0.000 0.000 0.459 WSW 0.000 0.000 0.000 0.551 0.046 0.000 0.000 0.000 0.000 0.597 W 0.000 0.000 0.000 0.138 0.459 0.230 0.000 0.000 0.000 0.826 WNW 0.000 0.000 0.000 0.000 0.000 0.138 0.092 0.000 0.000 0.230 NW 0.000 0.000 0.000 0.046 0.046 0.230 0.551 0.046 0.000 0.918 NNW 0.000 0.000 0.000 0.000 0.092 0.275 0.000 0.000 0.000 0.367 SUBTOTAL 0.000 0.000 3.352 4.637 1.882 1.607 0.643 0.046 0.000 12.167 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2178 TOTAL HOURS OF STABILITY CLASS A 265 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A 265 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2178 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2016/08/05 MEAN WIND SPEED = 5.42 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-54 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.321 0.230 0.000 0.000 0.000 0.551 NNE 0.000 0.000 0.000 0.000 0.184 0.138 0.000 0.000 0.000 0.321 NE 0.000 0.000 0.000 0.000 0.230 0.230 0.000 0.000 0.000 0.459 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.092 0.092 0.046 0.000 0.000 0.000 0.000 0.230 SE 0.000 0.000 0.459 0.184 0.046 0.000 0.000 0.000 0.000 0.689 SSE 0.000 0.000 0.321 0.000 0.000 0.000 0.000 0.000 0.000 0.321 S 0.000 0.000 0.321 0.275 0.000 0.000 0.000 0.000 0.000 0.597 SSW 0.000 0.000 0.413 0.275 0.000 0.000 0.000 0.000 0.000 0.689 SW 0.000 0.000 0.275 0.230 0.000 0.000 0.000 0.000 0.000 0.505 WSW 0.000 0.000 0.046 0.275 0.046 0.000 0.000 0.000 0.000 0.367 W 0.000 0.000 0.000 0.092 0.184 0.138 0.000 0.000 0.000 0.413 WNW 0.000 0.000 0.000 0.000 0.000 0.367 0.230 0.000 0.000 0.597 NW 0.000 0.000 0.000 0.000 0.230 0.321 0.138 0.000 0.000 0.689 NNW 0.000 0.000 0.000 0.000 0.138 0.551 0.092 0.000 0.000 0.781 SUBTOTAL 0.000 0.000 1.928 1.423 1.423 1.974 0.459 0.000 0.000 7.208 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2178 TOTAL HOURS OF STABILITY CLASS B 157 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B 157 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2178 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2016/08/05 MEAN WIND SPEED = 6.27 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-55 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.046 0.138 0.092 0.000 0.000 0.000 0.275 NNE 0.000 0.000 0.000 0.000 0.092 0.092 0.000 0.000 0.000 0.184 NE 0.000 0.000 0.000 0.184 0.092 0.046 0.000 0.000 0.000 0.321 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.092 0.046 0.000 0.000 0.000 0.000 0.000 0.138 ESE 0.000 0.000 0.000 0.092 0.092 0.000 0.000 0.000 0.000 0.184 SE 0.000 0.000 0.184 0.092 0.000 0.000 0.000 0.000 0.000 0.275 SSE 0.000 0.000 0.597 0.092 0.000 0.000 0.000 0.000 0.000 0.689 S 0.000 0.000 0.230 0.000 0.000 0.000 0.000 0.000 0.000 0.230 SSW 0.000 0.000 0.184 0.184 0.000 0.000 0.000 0.000 0.000 0.367 SW 0.000 0.000 0.230 0.092 0.000 0.000 0.000 0.000 0.000 0.321 WSW 0.000 0.000 0.092 0.321 0.000 0.000 0.000 0.000 0.000 0.413 W 0.000 0.000 0.000 0.046 0.459 0.184 0.000 0.000 0.000 0.689 WNW 0.000 0.000 0.046 0.000 0.138 0.505 0.321 0.000 0.000 1.010 NW 0.000 0.000 0.000 0.046 0.184 0.689 0.092 0.000 0.000 1.010 NNW 0.000 0.000 0.000 0.000 0.321 0.413 0.046 0.000 0.000 0.781 SUBTOTAL 0.000 0.000 1.653 1.240 1.515 2.020 0.459 0.000 0.000 6.887 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2178 TOTAL HOURS OF STABILITY CLASS C 150 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 150 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2178 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2016/08/05 MEAN WIND SPEED = 6.46 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-56 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.459 0.275 0.689 0.230 0.000 0.000 0.000 1.653 NNE 0.000 0.000 0.138 0.367 0.413 0.275 0.000 0.000 0.000 1.194 NE 0.000 0.046 0.092 0.551 0.551 0.092 0.000 0.000 0.000 1.331 ENE 0.000 0.000 0.230 0.092 0.046 0.000 0.000 0.000 0.000 0.367 E 0.000 0.046 0.138 0.321 0.092 0.000 0.000 0.000 0.000 0.597 ESE 0.000 0.000 0.597 0.505 0.781 0.046 0.000 0.000 0.000 1.928 SE 0.000 0.000 0.918 0.230 0.138 0.000 0.000 0.000 0.000 1.286 SSE 0.000 0.000 1.286 0.092 0.000 0.000 0.000 0.000 0.000 1.377 S 0.000 0.046 1.791 0.275 0.046 0.000 0.000 0.000 0.000 2.158 SSW 0.000 0.000 2.709 0.413 0.000 0.000 0.000 0.000 0.000 3.122 SW 0.000 0.046 0.918 0.000 0.000 0.000 0.000 0.000 0.000 0.964 WSW 0.000 0.000 1.056 0.689 0.046 0.046 0.000 0.000 0.000 1.837 W 0.000 0.000 0.643 1.653 0.735 0.275 0.000 0.000 0.000 3.306 WNW 0.000 0.000 0.046 0.321 0.505 1.469 0.230 0.000 0.000 2.571 NW 0.000 0.000 0.092 0.275 0.689 1.423 0.230 0.000 0.000 2.709 NNW 0.000 0.000 0.275 0.275 0.689 0.367 0.046 0.000 0.000 1.653 SUBTOTAL 0.000 0.184 11.387 6.336 5.418 4.224 0.505 0.000 0.000 28.053 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2178 TOTAL HOURS OF STABILITY CLASS D 611 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D 611 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2178 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2016/08/05 MEAN WIND SPEED = 4.86 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-57 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.046 0.597 0.459 0.138 0.138 0.000 0.000 0.000 1.377 NNE 0.000 0.092 0.459 0.413 0.597 0.000 0.000 0.000 0.000 1.561 NE 0.000 0.230 0.367 0.092 0.138 0.092 0.000 0.000 0.000 0.918 ENE 0.000 0.046 0.781 0.321 0.138 0.000 0.000 0.000 0.000 1.286 E 0.000 0.321 1.561 1.010 0.000 0.000 0.000 0.000 0.000 2.893 ESE 0.000 0.184 1.653 1.240 0.321 0.000 0.000 0.000 0.000 3.398 SE 0.000 0.092 0.964 0.000 0.092 0.000 0.000 0.000 0.000 1.148 SSE 0.000 0.138 1.010 0.046 0.000 0.000 0.000 0.000 0.000 1.194 S 0.000 0.413 2.663 0.230 0.092 0.000 0.000 0.000 0.000 3.398 SSW 0.000 0.092 1.377 0.138 0.000 0.000 0.000 0.000 0.000 1.607 SW 0.000 0.184 0.321 0.000 0.000 0.000 0.000 0.000 0.000 0.505 WSW 0.000 0.092 0.689 0.138 0.046 0.000 0.000 0.000 0.000 0.964 W 0.000 0.046 0.826 0.781 0.275 0.138 0.000 0.000 0.000 2.066 WNW 0.000 0.046 0.092 0.230 0.184 0.184 0.000 0.000 0.000 0.735 NW 0.000 0.000 0.275 0.184 0.230 0.275 0.000 0.000 0.000 0.964 NNW 0.000 0.000 0.826 0.689 0.551 0.184 0.000 0.000 0.000 2.250 SUBTOTAL 0.000 2.020 14.463 5.969 2.801 1.010 0.000 0.000 0.000 26.263 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2178 TOTAL HOURS OF STABILITY CLASS E 572 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E 572 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2178 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2016/08/05 MEAN WIND SPEED = 3.38 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-58 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.321 1.837 0.597 0.046 0.000 0.000 0.000 0.000 2.801 NNE 0.000 0.092 0.413 0.275 0.000 0.000 0.000 0.000 0.000 0.781 NE 0.000 0.184 0.551 0.184 0.092 0.000 0.000 0.000 0.000 1.010 ENE 0.000 0.184 0.781 0.275 0.000 0.000 0.000 0.000 0.000 1.240 E 0.000 0.551 1.010 0.275 0.000 0.000 0.000 0.000 0.000 1.837 ESE 0.000 0.184 0.689 0.138 0.046 0.000 0.000 0.000 0.000 1.056 SE 0.000 0.321 0.230 0.000 0.000 0.000 0.000 0.000 0.000 0.551 SSE 0.000 0.184 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.230 S 0.000 0.138 0.505 0.000 0.000 0.000 0.000 0.000 0.000 0.643 SSW 0.000 0.000 0.138 0.000 0.000 0.000 0.000 0.000 0.000 0.138 SW 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.092 WSW 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 W 0.000 0.092 0.230 0.000 0.000 0.000 0.000 0.000 0.000 0.321 WNW 0.000 0.046 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.138 NW 0.000 0.138 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.138 NNW 0.000 0.230 1.010 0.551 0.046 0.000 0.000 0.000 0.000 1.837 SUBTOTAL 0.000 2.801 7.576 2.296 0.230 0.000 0.000 0.000 0.000 12.902 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2178 TOTAL HOURS OF STABILITY CLASS F 281 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F 281 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2178 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2016/08/05 MEAN WIND SPEED = 2.50 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-59 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.413 0.872 0.275 0.000 0.000 0.000 0.000 0.000 1.561 NNE 0.000 0.781 0.230 0.092 0.000 0.000 0.000 0.000 0.000 1.102 NE 0.000 0.367 0.367 0.000 0.000 0.000 0.000 0.000 0.000 0.735 ENE 0.000 0.367 0.184 0.092 0.000 0.000 0.000 0.000 0.000 0.643 E 0.000 0.184 0.184 0.000 0.000 0.000 0.000 0.000 0.000 0.367 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.092 SSE 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 S 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.092 SSW 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 SW 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 WNW 0.000 0.092 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.184 NW 0.000 0.413 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.459 NNW 0.000 0.459 0.643 0.000 0.000 0.000 0.000 0.000 0.000 1.102 SUBTOTAL 0.000 3.260 2.801 0.459 0.000 0.000 0.000 0.000 0.000 6.520 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2178 TOTAL HOURS OF STABILITY CLASS G 142 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G 142 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2178 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2016/08/05 MEAN WIND SPEED = 1.71 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-60 BROWNS FERRY NUCLEAR PLANT 2016 METEOROLOGICAL DATA TABLE 7C JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES THIRD QUARTER

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-61 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.046 0.457 0.822 0.000 0.000 0.000 1.325 NNE 0.000 0.000 0.000 0.091 0.183 0.228 0.000 0.000 0.000 0.503 NE 0.000 0.000 0.000 0.000 0.046 0.228 0.000 0.000 0.000 0.274 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 ESE 0.000 0.000 0.046 0.411 0.228 0.046 0.000 0.000 0.000 0.731 SE 0.000 0.000 0.777 1.233 0.000 0.000 0.000 0.000 0.000 2.010 SSE 0.000 0.000 1.279 1.279 0.000 0.000 0.000 0.000 0.000 2.558 S 0.000 0.000 1.873 0.777 0.000 0.000 0.000 0.000 0.000 2.650 SSW 0.000 0.000 0.640 0.503 0.000 0.000 0.000 0.000 0.000 1.142 SW 0.000 0.000 0.091 0.183 0.000 0.000 0.000 0.000 0.000 0.274 WSW 0.000 0.000 0.046 0.685 0.320 0.046 0.000 0.000 0.000 1.096 W 0.000 0.000 0.000 0.183 0.503 0.228 0.000 0.000 0.000 0.914 WNW 0.000 0.000 0.046 0.000 0.183 0.411 0.000 0.000 0.000 0.640 NW 0.000 0.000 0.000 0.000 0.137 0.274 0.000 0.000 0.000 0.411 NNW 0.000 0.000 0.000 0.000 0.137 0.365 0.000 0.000 0.000 0.503 SUBTOTAL 0.000 0.000 4.797 5.436 2.193 2.650 0.000 0.000 0.000 15.075 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2189 TOTAL HOURS OF STABILITY CLASS A 330 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A 330 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2189 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2017/01/10 MEAN WIND SPEED = 4.94 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-62 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.137 0.183 0.091 0.000 0.000 0.000 0.411 NNE 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 NE 0.000 0.000 0.000 0.091 0.046 0.000 0.000 0.000 0.000 0.137 ENE 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.137 0.274 0.091 0.000 0.000 0.000 0.000 0.503 SE 0.000 0.000 0.320 0.411 0.000 0.000 0.000 0.000 0.000 0.731 SSE 0.000 0.000 0.411 0.183 0.000 0.000 0.000 0.000 0.000 0.594 S 0.000 0.000 0.457 0.228 0.000 0.000 0.000 0.000 0.000 0.685 SSW 0.000 0.000 0.640 0.228 0.000 0.000 0.000 0.000 0.000 0.868 SW 0.000 0.000 0.137 0.183 0.000 0.000 0.000 0.000 0.000 0.320 WSW 0.000 0.000 0.046 0.457 0.228 0.000 0.000 0.000 0.000 0.731 W 0.000 0.000 0.046 0.457 0.503 0.137 0.000 0.000 0.000 1.142 WNW 0.000 0.000 0.000 0.046 0.228 0.320 0.000 0.000 0.000 0.594 NW 0.000 0.000 0.000 0.137 0.091 0.137 0.000 0.000 0.000 0.365 NNW 0.000 0.000 0.000 0.046 0.046 0.091 0.000 0.000 0.000 0.183 SUBTOTAL 0.000 0.000 2.193 2.924 1.462 0.777 0.000 0.000 0.000 7.355 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2189 TOTAL HOURS OF STABILITY CLASS B 161 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B 161 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2189 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2017/01/10 MEAN WIND SPEED = 4.71 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-63 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.046 0.046 0.046 0.000 0.000 0.000 0.137 NNE 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 NE 0.000 0.000 0.000 0.046 0.137 0.091 0.000 0.000 0.000 0.274 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.091 ESE 0.000 0.000 0.137 0.365 0.091 0.000 0.000 0.000 0.000 0.594 SE 0.000 0.000 0.548 0.046 0.000 0.000 0.000 0.000 0.000 0.594 SSE 0.000 0.000 0.365 0.000 0.000 0.000 0.000 0.000 0.000 0.365 S 0.000 0.000 0.411 0.137 0.000 0.000 0.000 0.000 0.000 0.548 SSW 0.000 0.000 0.548 0.183 0.000 0.000 0.000 0.000 0.000 0.731 SW 0.000 0.000 0.594 0.000 0.000 0.000 0.000 0.000 0.000 0.594 WSW 0.000 0.000 0.137 0.411 0.091 0.000 0.000 0.000 0.000 0.640 W 0.000 0.000 0.000 0.457 0.320 0.046 0.000 0.000 0.000 0.822 WNW 0.000 0.000 0.000 0.091 0.183 0.183 0.000 0.000 0.000 0.457 NW 0.000 0.000 0.000 0.137 0.137 0.000 0.046 0.000 0.000 0.320 NNW 0.000 0.000 0.000 0.000 0.091 0.046 0.000 0.000 0.000 0.137 SUBTOTAL 0.000 0.000 2.787 1.964 1.142 0.411 0.046 0.000 0.000 6.350 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2189 TOTAL HOURS OF STABILITY CLASS C 139 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 139 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2189 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2017/01/10 MEAN WIND SPEED = 4.33 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-64 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.228 0.685 0.320 0.183 0.000 0.000 0.000 1.416 NNE 0.000 0.000 0.137 0.548 0.411 0.137 0.000 0.000 0.000 1.233 NE 0.000 0.046 0.274 0.503 0.320 0.228 0.000 0.000 0.000 1.370 ENE 0.000 0.000 0.274 0.274 0.183 0.000 0.000 0.000 0.000 0.731 E 0.000 0.000 0.457 0.594 0.183 0.000 0.000 0.000 0.000 1.233 ESE 0.000 0.046 0.685 1.188 0.274 0.000 0.000 0.000 0.000 2.193 SE 0.000 0.000 1.096 0.091 0.000 0.000 0.000 0.000 0.000 1.188 SSE 0.000 0.046 1.964 0.091 0.000 0.000 0.000 0.000 0.000 2.101 S 0.000 0.137 2.924 0.183 0.000 0.000 0.000 0.000 0.000 3.243 SSW 0.000 0.046 2.695 0.365 0.000 0.000 0.000 0.000 0.000 3.106 SW 0.000 0.000 1.416 0.000 0.000 0.000 0.000 0.000 0.000 1.416 WSW 0.000 0.046 1.370 0.822 0.183 0.000 0.000 0.000 0.000 2.421 W 0.000 0.000 0.640 1.005 0.503 0.228 0.000 0.000 0.000 2.376 WNW 0.000 0.046 0.320 0.594 0.091 0.411 0.000 0.000 0.000 1.462 NW 0.000 0.000 0.183 0.091 0.046 0.183 0.000 0.000 0.000 0.503 NNW 0.000 0.000 0.183 0.183 0.274 0.274 0.000 0.000 0.000 0.914 SUBTOTAL 0.000 0.411 14.847 7.218 2.787 1.645 0.000 0.000 0.000 26.907 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2189 TOTAL HOURS OF STABILITY CLASS D 589 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D 589 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2189 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2017/01/10 MEAN WIND SPEED = 3.71 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-65 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.046 1.279 1.096 0.046 0.000 0.000 0.000 0.000 2.467 NNE 0.000 0.137 0.822 1.233 0.457 0.091 0.000 0.000 0.000 2.741 NE 0.000 0.411 0.685 0.685 0.594 0.183 0.000 0.000 0.000 2.558 ENE 0.000 0.228 1.370 0.548 0.091 0.000 0.000 0.000 0.000 2.238 E 0.000 0.274 1.645 0.777 0.137 0.000 0.000 0.000 0.000 2.832 ESE 0.000 0.137 1.690 0.365 0.000 0.000 0.000 0.000 0.000 2.193 SE 0.000 0.320 0.822 0.000 0.000 0.000 0.000 0.000 0.000 1.142 SSE 0.000 0.457 0.411 0.046 0.000 0.000 0.000 0.000 0.000 0.914 S 0.000 0.365 1.279 0.046 0.000 0.000 0.000 0.000 0.000 1.690 SSW 0.000 0.320 1.416 0.183 0.000 0.000 0.000 0.000 0.000 1.919 SW 0.000 0.183 0.503 0.000 0.000 0.000 0.000 0.000 0.000 0.685 WSW 0.000 0.091 0.594 0.091 0.000 0.000 0.000 0.000 0.000 0.777 W 0.000 0.000 0.457 0.503 0.091 0.000 0.000 0.000 0.000 1.051 WNW 0.000 0.000 0.274 0.046 0.046 0.000 0.000 0.000 0.000 0.365 NW 0.000 0.137 0.274 0.137 0.000 0.046 0.000 0.000 0.000 0.594 NNW 0.000 0.046 0.503 0.365 0.274 0.000 0.000 0.000 0.000 1.188 SUBTOTAL 0.000 3.152 14.025 6.122 1.736 0.320 0.000 0.000 0.000 25.354 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2189 TOTAL HOURS OF STABILITY CLASS E 555 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E 555 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2189 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2017/01/10 MEAN WIND SPEED = 3.00 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-66 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.137 1.325 0.503 0.000 0.000 0.000 0.000 0.000 1.964 NNE 0.000 0.365 1.279 0.777 0.228 0.000 0.000 0.000 0.000 2.650 NE 0.000 0.091 1.279 0.228 0.046 0.000 0.000 0.000 0.000 1.645 ENE 0.000 0.046 1.370 0.183 0.000 0.000 0.000 0.000 0.000 1.599 E 0.000 0.320 1.827 0.320 0.000 0.000 0.000 0.000 0.000 2.467 ESE 0.000 0.228 0.320 0.000 0.000 0.000 0.000 0.000 0.000 0.548 SE 0.000 0.091 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.228 SSE 0.000 0.183 0.320 0.000 0.000 0.000 0.000 0.000 0.000 0.503 S 0.000 0.091 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.183 SSW 0.000 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.137 SW 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.091 WSW 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.091 W 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.091 WNW 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 NW 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.091 NNW 0.000 0.091 0.320 0.046 0.000 0.000 0.000 0.000 0.000 0.457 SUBTOTAL 0.000 1.873 8.543 2.101 0.274 0.000 0.000 0.000 0.000 12.791 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2189 TOTAL HOURS OF STABILITY CLASS F 280 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F 280 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2189 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2017/01/10 MEAN WIND SPEED = 2.54 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-67 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.015 1.051 0.822 0.046 0.000 0.000 0.000 0.000 0.000 1.933 NNE 0.007 0.503 0.365 0.046 0.000 0.000 0.000 0.000 0.000 0.920 NE 0.004 0.137 0.411 0.000 0.000 0.000 0.000 0.000 0.000 0.552 ENE 0.006 0.228 0.503 0.046 0.046 0.000 0.000 0.000 0.000 0.828 E 0.003 0.091 0.320 0.000 0.000 0.000 0.000 0.000 0.000 0.414 ESE 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.092 SE 0.001 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.138 SSE 0.001 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.138 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 W 0.001 0.091 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.138 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.002 0.183 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.276 NNW 0.005 0.457 0.183 0.000 0.000 0.000 0.000 0.000 0.000 0.645 SUBTOTAL 0.046 3.061 2.787 0.183 0.091 0.000 0.000 0.000 0.000 6.167 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2189 TOTAL HOURS OF STABILITY CLASS G 135 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G 135 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2189 TOTAL HOURS CALM 1 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2017/01/10 MEAN WIND SPEED = 1.80 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-68 BROWNS FERRY NUCLEAR PLANT 2016 METEOROLOGICAL DATA TABLE 7D JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES FOURTH QUARTER

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-69 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.635 0.045 0.000 0.000 0.681 NNE 0.000 0.000 0.000 0.000 0.000 0.454 0.000 0.000 0.000 0.454 NE 0.000 0.000 0.000 0.000 0.000 0.045 0.136 0.000 0.000 0.181 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.045 ESE 0.000 0.000 0.045 0.181 0.318 0.000 0.000 0.000 0.000 0.544 SE 0.000 0.000 0.272 1.543 0.136 0.000 0.000 0.000 0.000 1.951 SSE 0.000 0.000 0.862 0.862 0.000 0.000 0.000 0.000 0.000 1.724 S 0.000 0.000 0.499 0.408 0.000 0.000 0.000 0.000 0.000 0.907 SSW 0.000 0.000 0.045 0.544 0.045 0.000 0.000 0.000 0.000 0.635 SW 0.000 0.000 0.000 0.136 0.000 0.000 0.000 0.000 0.000 0.136 WSW 0.000 0.000 0.045 0.091 0.000 0.000 0.000 0.000 0.000 0.136 W 0.000 0.000 0.000 0.045 0.091 0.000 0.000 0.000 0.000 0.136 WNW 0.000 0.000 0.045 0.000 0.045 0.136 0.000 0.000 0.000 0.227 NW 0.000 0.000 0.000 0.000 0.045 0.408 0.227 0.000 0.000 0.681 NNW 0.000 0.000 0.000 0.000 0.045 0.363 0.181 0.000 0.000 0.590 SUBTOTAL 0.000 0.000 1.815 3.811 0.771 2.042 0.590 0.000 0.000 9.029 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2204 TOTAL HOURS OF STABILITY CLASS A 199 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A 199 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2204 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2017/01/27 MEAN WIND SPEED = 5.91 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-70 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.272 0.000 0.000 0.000 0.272 NNE 0.000 0.000 0.000 0.000 0.091 0.272 0.000 0.000 0.000 0.363 NE 0.000 0.000 0.000 0.000 0.091 0.000 0.045 0.000 0.000 0.136 ENE 0.000 0.000 0.045 0.000 0.045 0.000 0.000 0.000 0.000 0.091 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.091 SE 0.000 0.000 0.181 0.272 0.000 0.000 0.000 0.000 0.000 0.454 SSE 0.000 0.000 0.181 0.000 0.000 0.000 0.000 0.000 0.000 0.181 S 0.000 0.000 0.181 0.181 0.000 0.000 0.000 0.000 0.000 0.363 SSW 0.000 0.000 0.045 0.045 0.000 0.000 0.000 0.000 0.000 0.091 SW 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.045 WSW 0.000 0.000 0.045 0.091 0.000 0.000 0.000 0.000 0.000 0.136 W 0.000 0.000 0.000 0.136 0.000 0.000 0.000 0.000 0.000 0.136 WNW 0.000 0.000 0.045 0.136 0.091 0.318 0.000 0.000 0.000 0.590 NW 0.000 0.000 0.000 0.000 0.136 0.318 0.091 0.091 0.000 0.635 NNW 0.000 0.000 0.000 0.000 0.045 0.272 0.045 0.000 0.000 0.363 SUBTOTAL 0.000 0.000 0.771 0.953 0.499 1.452 0.181 0.091 0.000 3.947 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2204 TOTAL HOURS OF STABILITY CLASS B 87 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B 87 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2204 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2017/01/27 MEAN WIND SPEED = 6.84 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-71 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.272 0.091 0.000 0.000 0.000 0.363 NNE 0.000 0.000 0.000 0.000 0.181 0.181 0.000 0.000 0.000 0.363 NE 0.000 0.000 0.000 0.000 0.136 0.091 0.000 0.000 0.000 0.227 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.045 ESE 0.000 0.000 0.045 0.181 0.136 0.000 0.000 0.000 0.000 0.363 SE 0.000 0.000 0.318 0.181 0.000 0.000 0.000 0.000 0.000 0.499 SSE 0.000 0.000 0.544 0.091 0.000 0.000 0.000 0.000 0.000 0.635 S 0.000 0.000 0.136 0.000 0.000 0.000 0.000 0.000 0.000 0.136 SSW 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.045 SW 0.000 0.000 0.091 0.045 0.000 0.000 0.000 0.000 0.000 0.136 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.045 0.000 0.045 0.000 0.000 0.000 0.091 WNW 0.000 0.000 0.000 0.227 0.318 0.227 0.091 0.000 0.000 0.862 NW 0.000 0.000 0.045 0.045 0.091 0.136 0.091 0.045 0.000 0.454 NNW 0.000 0.000 0.000 0.136 0.272 0.318 0.000 0.000 0.000 0.726 SUBTOTAL 0.000 0.000 1.225 0.998 1.407 1.089 0.181 0.045 0.000 4.946 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2204 TOTAL HOURS OF STABILITY CLASS C 109 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 109 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2204 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2017/01/27 MEAN WIND SPEED = 6.20 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-72 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.045 0.136 1.044 0.726 0.726 0.000 0.000 0.000 2.677 NNE 0.000 0.000 0.454 0.907 0.771 0.726 0.000 0.000 0.000 2.858 NE 0.000 0.045 0.363 0.953 0.544 0.136 0.000 0.000 0.000 2.042 ENE 0.000 0.000 0.181 0.363 0.136 0.000 0.000 0.000 0.000 0.681 E 0.000 0.000 0.499 0.227 0.091 0.000 0.000 0.000 0.000 0.817 ESE 0.000 0.000 0.817 0.907 0.318 0.000 0.000 0.000 0.000 2.042 SE 0.000 0.000 0.953 0.181 0.000 0.000 0.000 0.000 0.000 1.134 SSE 0.000 0.045 1.452 0.136 0.000 0.000 0.000 0.000 0.000 1.633 S 0.000 0.091 0.681 0.590 0.045 0.000 0.000 0.000 0.000 1.407 SSW 0.000 0.000 0.454 0.000 0.000 0.000 0.000 0.000 0.000 0.454 SW 0.000 0.000 0.136 0.000 0.000 0.000 0.000 0.000 0.000 0.136 WSW 0.000 0.000 0.454 0.091 0.045 0.000 0.000 0.000 0.000 0.590 W 0.000 0.000 0.227 0.499 0.227 0.136 0.000 0.000 0.000 1.089 WNW 0.000 0.000 0.045 0.408 0.408 0.907 0.136 0.000 0.000 1.906 NW 0.000 0.000 0.045 0.454 0.635 1.316 1.044 0.045 0.000 3.539 NNW 0.000 0.000 0.091 0.363 1.089 1.361 0.136 0.000 0.000 3.040 SUBTOTAL 0.000 0.227 6.987 7.123 5.036 5.309 1.316 0.045 0.000 26.044 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2204 TOTAL HOURS OF STABILITY CLASS D 574 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D 574 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2204 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2017/01/27 MEAN WIND SPEED = 5.83 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-73 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.045 0.998 0.454 0.091 0.227 0.000 0.000 0.000 1.815 NNE 0.000 0.045 0.363 0.817 0.408 0.091 0.000 0.000 0.000 1.724 NE 0.000 0.000 0.771 0.318 0.272 0.136 0.000 0.000 0.000 1.497 ENE 0.000 0.272 0.272 0.227 0.091 0.000 0.000 0.000 0.000 0.862 E 0.000 0.136 0.907 0.635 0.000 0.000 0.000 0.000 0.000 1.679 ESE 0.000 0.227 1.815 1.633 0.045 0.000 0.000 0.000 0.000 3.721 SE 0.000 0.181 0.998 0.227 0.000 0.000 0.000 0.000 0.000 1.407 SSE 0.000 0.136 0.998 0.227 0.045 0.000 0.000 0.000 0.000 1.407 S 0.000 0.091 1.089 0.544 0.499 0.227 0.000 0.000 0.000 2.450 SSW 0.000 0.000 0.318 0.136 0.227 0.000 0.000 0.000 0.000 0.681 SW 0.000 0.091 0.091 0.045 0.000 0.000 0.000 0.000 0.000 0.227 WSW 0.000 0.045 0.181 0.000 0.045 0.000 0.000 0.000 0.000 0.272 W 0.000 0.136 0.635 0.091 0.000 0.045 0.000 0.000 0.000 0.907 WNW 0.000 0.045 0.136 0.181 0.045 0.091 0.091 0.000 0.000 0.590 NW 0.000 0.000 0.408 0.363 0.136 0.363 0.000 0.045 0.000 1.316 NNW 0.000 0.045 0.726 0.998 0.408 0.499 0.000 0.000 0.000 2.677 SUBTOTAL 0.000 1.497 10.708 6.897 2.314 1.679 0.091 0.045 0.000 23.230 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2204 TOTAL HOURS OF STABILITY CLASS E 512 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E 512 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2204 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2017/01/27 MEAN WIND SPEED = 3.87 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-74 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.005 0.181 1.316 0.635 0.091 0.000 0.000 0.000 0.000 2.229 NNE 0.002 0.091 0.408 1.134 0.136 0.000 0.000 0.000 0.000 1.771 NE 0.002 0.272 0.318 0.318 0.136 0.000 0.000 0.000 0.000 1.046 ENE 0.004 0.181 0.817 0.091 0.000 0.000 0.000 0.000 0.000 1.092 E 0.005 0.227 1.270 0.544 0.000 0.000 0.000 0.000 0.000 2.047 ESE 0.007 0.499 1.361 0.091 0.000 0.000 0.000 0.000 0.000 1.958 SE 0.004 0.544 0.544 0.136 0.000 0.000 0.000 0.000 0.000 1.229 SSE 0.003 0.544 0.363 0.045 0.045 0.000 0.000 0.000 0.000 1.001 S 0.003 0.091 0.817 0.817 0.499 0.272 0.000 0.000 0.000 2.499 SSW 0.001 0.136 0.091 0.045 0.000 0.000 0.000 0.000 0.000 0.273 SW 0.001 0.136 0.045 0.045 0.000 0.000 0.000 0.000 0.000 0.228 WSW 0.001 0.227 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.319 W 0.001 0.091 0.227 0.000 0.000 0.000 0.000 0.000 0.000 0.319 WNW 0.001 0.181 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.273 NW 0.002 0.136 0.408 0.045 0.000 0.000 0.000 0.000 0.000 0.592 NNW 0.004 0.091 0.907 0.544 0.045 0.000 0.000 0.000 0.000 1.592 SUBTOTAL 0.045 3.630 9.074 4.492 0.953 0.272 0.000 0.000 0.000 18.466 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2204 TOTAL HOURS OF STABILITY CLASS F 407 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F 407 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2204 TOTAL HOURS CALM 1 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2017/01/27 MEAN WIND SPEED = 2.88 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-75 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.016 1.316 0.998 0.681 0.000 0.000 0.000 0.000 0.000 3.011 NNE 0.011 1.134 0.454 0.091 0.000 0.000 0.000 0.000 0.000 1.690 NE 0.009 0.454 0.817 0.045 0.000 0.000 0.000 0.000 0.000 1.325 ENE 0.010 0.318 1.089 0.045 0.000 0.000 0.000 0.000 0.000 1.462 E 0.009 0.363 0.907 0.045 0.000 0.000 0.000 0.000 0.000 1.325 ESE 0.003 0.318 0.181 0.000 0.000 0.000 0.000 0.000 0.000 0.503 SE 0.006 0.635 0.181 0.045 0.000 0.000 0.000 0.000 0.000 0.868 SSE 0.009 0.590 0.681 0.000 0.000 0.000 0.000 0.000 0.000 1.279 S 0.006 0.227 0.590 0.000 0.227 0.000 0.000 0.000 0.000 1.049 SSW 0.002 0.227 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.320 SW 0.001 0.136 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.183 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.001 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 WNW 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 NW 0.002 0.227 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.320 NNW 0.006 0.454 0.363 0.045 0.000 0.000 0.000 0.000 0.000 0.868 SUBTOTAL 0.091 6.534 6.488 0.998 0.227 0.000 0.000 0.000 0.000 14.338 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2204 TOTAL HOURS OF STABILITY CLASS G 316 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G 316 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2204 TOTAL HOURS CALM 2 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2017/01/27 MEAN WIND SPEED = 1.85 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-76 BROWNS FERRY NUCLEAR PLANT 2016 METEOROLOGICAL DATA TABLE 8A JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL RELEASE MODE AND ELEVATED RELEASE MODE)

FIRST QUARTER

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-77 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.028 0.000 0.000 0.000 0.028 NNE 0.000 0.000 0.000 0.000 0.000 0.007 0.000 0.000 0.000 0.007 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.005 0.000 0.000 0.000 0.000 0.005 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.007 0.005 0.000 0.000 0.000 0.000 0.012 SE 0.000 0.000 0.000 0.010 0.000 0.000 0.000 0.000 0.000 0.010 SSE 0.000 0.000 0.012 0.016 0.000 0.000 0.000 0.000 0.000 0.028 S 0.000 0.000 0.010 0.020 0.083 0.019 0.000 0.000 0.000 0.132 SSW 0.000 0.000 0.007 0.027 0.017 0.000 0.000 0.000 0.000 0.051 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.006 0.000 0.000 0.000 0.000 0.000 0.006 W 0.000 0.000 0.000 0.000 0.000 0.008 0.000 0.000 0.000 0.008 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.000 0.000 0.009 NNW 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.000 0.000 0.009 SUBTOTAL 0.000 0.000 0.029 0.088 0.111 0.079 0.000 0.000 0.000 0.306 TOTAL HOURS OF VALID OBSERVATIONS 2159.000 TOTAL HOURS OF GROUND LEVEL RELEASE 326.730 TOTAL HOURS OF STABILITY CLASS A 13.570 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS A 6.610 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/05/06 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-78 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.037 0.000 0.000 0.000 0.037 NNE 0.000 0.000 0.000 0.000 0.007 0.016 0.000 0.000 0.000 0.023 NE 0.000 0.000 0.000 0.000 0.000 0.014 0.000 0.000 0.000 0.014 ENE 0.000 0.000 0.000 0.000 0.010 0.000 0.000 0.000 0.000 0.010 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.010 0.000 0.000 0.000 0.000 0.000 0.010 SE 0.000 0.000 0.000 0.015 0.008 0.000 0.000 0.000 0.000 0.023 SSE 0.000 0.000 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.008 S 0.000 0.000 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.009 SSW 0.000 0.000 0.000 0.013 0.011 0.000 0.000 0.000 0.000 0.023 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.006 0.000 0.000 0.000 0.000 0.006 W 0.000 0.000 0.000 0.000 0.010 0.000 0.000 0.000 0.000 0.010 WNW 0.000 0.000 0.000 0.000 0.000 0.021 0.066 0.000 0.000 0.087 NW 0.000 0.000 0.000 0.000 0.000 0.025 0.035 0.000 0.000 0.059 NNW 0.000 0.000 0.000 0.000 0.000 0.008 0.027 0.000 0.000 0.035 SUBTOTAL 0.000 0.000 0.008 0.037 0.061 0.120 0.128 0.000 0.000 0.354 TOTAL HOURS OF VALID OBSERVATIONS 2159.000 TOTAL HOURS OF GROUND LEVEL RELEASE 326.730 TOTAL HOURS OF STABILITY CLASS B 27.510 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS B 7.640 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/05/06 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-79 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.004 0.014 0.000 0.000 0.000 0.018 NNE 0.000 0.000 0.000 0.000 0.006 0.007 0.000 0.000 0.000 0.013 NE 0.000 0.000 0.000 0.000 0.003 0.000 0.000 0.000 0.000 0.003 ENE 0.000 0.000 0.000 0.000 0.012 0.006 0.000 0.000 0.000 0.018 E 0.000 0.000 0.000 0.000 0.006 0.000 0.000 0.000 0.000 0.006 ESE 0.000 0.000 0.000 0.006 0.000 0.000 0.000 0.000 0.000 0.006 SE 0.000 0.000 0.008 0.013 0.008 0.000 0.000 0.000 0.000 0.029 SSE 0.000 0.000 0.020 0.000 0.000 0.000 0.000 0.000 0.000 0.020 S 0.000 0.000 0.007 0.000 0.014 0.000 0.000 0.000 0.000 0.021 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.024 0.000 0.000 0.000 0.024 W 0.000 0.000 0.000 0.000 0.006 0.017 0.000 0.000 0.000 0.023 WNW 0.000 0.000 0.000 0.000 0.006 0.057 0.105 0.000 0.000 0.169 NW 0.000 0.000 0.000 0.000 0.005 0.057 0.028 0.000 0.000 0.090 NNW 0.000 0.000 0.000 0.000 0.008 0.038 0.000 0.000 0.000 0.046 SUBTOTAL 0.000 0.000 0.036 0.019 0.079 0.220 0.133 0.000 0.000 0.487 TOTAL HOURS OF VALID OBSERVATIONS 2159.000 TOTAL HOURS OF GROUND LEVEL RELEASE 326.730 TOTAL HOURS OF STABILITY CLASS C 65.970 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS C 10.520 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/05/06 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-80 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.004 0.043 0.101 0.077 0.000 0.000 0.000 0.225 NNE 0.000 0.000 0.002 0.063 0.064 0.074 0.000 0.000 0.000 0.203 NE 0.000 0.000 0.000 0.021 0.038 0.022 0.000 0.000 0.000 0.081 ENE 0.000 0.000 0.000 0.034 0.032 0.000 0.000 0.000 0.000 0.066 E 0.000 0.000 0.000 0.019 0.012 0.000 0.000 0.000 0.000 0.031 ESE 0.000 0.000 0.002 0.035 0.047 0.000 0.000 0.000 0.000 0.085 SE 0.000 0.000 0.044 0.083 0.039 0.000 0.000 0.000 0.000 0.167 SSE 0.000 0.000 0.051 0.078 0.000 0.000 0.000 0.000 0.000 0.130 S 0.000 0.000 0.032 0.107 0.204 0.040 0.000 0.000 0.000 0.382 SSW 0.000 0.000 0.006 0.013 0.083 0.000 0.000 0.000 0.000 0.101 SW 0.000 0.000 0.000 0.020 0.009 0.000 0.000 0.000 0.000 0.029 WSW 0.000 0.000 0.002 0.032 0.011 0.052 0.000 0.000 0.000 0.098 W 0.000 0.000 0.000 0.031 0.061 0.145 0.020 0.000 0.000 0.257 WNW 0.000 0.000 0.000 0.014 0.069 0.280 0.510 0.066 0.000 0.939 NW 0.000 0.000 0.000 0.014 0.086 0.559 0.481 0.000 0.000 1.140 NNW 0.000 0.000 0.003 0.017 0.181 0.329 0.437 0.000 0.000 0.966 SUBTOTAL 0.000 0.000 0.146 0.624 1.037 1.578 1.448 0.066 0.000 4.899 TOTAL HOURS OF VALID OBSERVATIONS 2159.000 TOTAL HOURS OF GROUND LEVEL RELEASE 326.730 TOTAL HOURS OF STABILITY CLASS D 871.620 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS D 105.760 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/05/06 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-81 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.014 0.027 0.038 0.025 0.000 0.000 0.000 0.106 NNE 0.000 0.000 0.018 0.044 0.064 0.031 0.000 0.000 0.000 0.158 NE 0.000 0.000 0.016 0.028 0.047 0.053 0.000 0.000 0.000 0.145 ENE 0.000 0.000 0.006 0.035 0.011 0.009 0.010 0.000 0.000 0.071 E 0.000 0.000 0.063 0.025 0.008 0.000 0.000 0.000 0.000 0.096 ESE 0.000 0.000 0.031 0.131 0.040 0.055 0.000 0.000 0.000 0.256 SE 0.000 0.001 0.098 0.201 0.021 0.000 0.000 0.000 0.000 0.322 SSE 0.000 0.007 0.185 0.372 0.032 0.000 0.000 0.000 0.000 0.596 S 0.000 0.006 0.167 0.389 0.366 0.371 0.000 0.000 0.000 1.300 SSW 0.000 0.000 0.053 0.052 0.107 0.067 0.000 0.000 0.000 0.278 SW 0.000 0.000 0.045 0.027 0.008 0.032 0.000 0.000 0.000 0.113 WSW 0.000 0.000 0.021 0.056 0.007 0.000 0.000 0.000 0.000 0.085 W 0.000 0.000 0.018 0.058 0.034 0.026 0.000 0.000 0.000 0.136 WNW 0.000 0.000 0.002 0.000 0.023 0.039 0.000 0.000 0.000 0.065 NW 0.000 0.000 0.005 0.038 0.145 0.131 0.013 0.000 0.000 0.332 NNW 0.000 0.000 0.031 0.083 0.232 0.101 0.000 0.000 0.000 0.447 SUBTOTAL 0.000 0.015 0.774 1.567 1.185 0.941 0.022 0.000 0.000 4.504 TOTAL HOURS OF VALID OBSERVATIONS 2159.000 TOTAL HOURS OF GROUND LEVEL RELEASE 326.730 TOTAL HOURS OF STABILITY CLASS E 811.390 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS E 97.250 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/05/06 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-82 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.002 0.061 0.049 0.000 0.000 0.000 0.000 0.000 0.112 NNE 0.000 0.000 0.032 0.052 0.008 0.000 0.000 0.000 0.000 0.093 NE 0.000 0.000 0.005 0.006 0.000 0.000 0.000 0.000 0.000 0.010 ENE 0.000 0.000 0.007 0.011 0.000 0.000 0.000 0.000 0.000 0.018 E 0.000 0.000 0.015 0.025 0.000 0.000 0.000 0.000 0.000 0.041 ESE 0.000 0.005 0.020 0.018 0.000 0.000 0.000 0.000 0.000 0.043 SE 0.000 0.010 0.139 0.094 0.031 0.000 0.000 0.000 0.000 0.274 SSE 0.000 0.028 0.374 0.204 0.040 0.000 0.000 0.000 0.000 0.646 S 0.000 0.013 0.192 0.494 0.655 0.045 0.000 0.000 0.000 1.398 SSW 0.000 0.000 0.038 0.025 0.057 0.018 0.000 0.000 0.000 0.137 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.007 NW 0.000 0.000 0.012 0.018 0.000 0.000 0.000 0.000 0.000 0.030 NNW 0.000 0.000 0.043 0.038 0.015 0.008 0.000 0.000 0.000 0.105 SUBTOTAL 0.000 0.064 0.939 1.032 0.807 0.071 0.000 0.000 0.000 2.913 TOTAL HOURS OF VALID OBSERVATIONS 2159.000 TOTAL HOURS OF GROUND LEVEL RELEASE 326.730 TOTAL HOURS OF STABILITY CLASS F 303.450 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS F 62.890 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/05/06 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-83 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.027 0.020 0.000 0.000 0.000 0.000 0.000 0.047 NNE 0.000 0.000 0.000 0.017 0.000 0.000 0.000 0.000 0.000 0.017 NE 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.009 ENE 0.000 0.000 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.005 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.012 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.018 SE 0.000 0.000 0.017 0.023 0.000 0.000 0.000 0.000 0.000 0.040 SSE 0.000 0.040 0.416 0.494 0.000 0.000 0.000 0.000 0.000 0.950 S 0.000 0.000 0.194 0.197 0.163 0.000 0.000 0.000 0.000 0.554 SSW 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.004 0.006 0.000 0.000 0.000 0.000 0.000 0.009 NNW 0.000 0.000 0.011 0.000 0.000 0.000 0.000 0.000 0.000 0.011 SUBTOTAL 0.000 0.062 0.688 0.757 0.163 0.000 0.000 0.000 0.000 1.670 TOTAL HOURS OF VALID OBSERVATIONS 2159.000 TOTAL HOURS OF GROUND LEVEL RELEASE 326.730 TOTAL HOURS OF STABILITY CLASS G 65.490 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS G 36.060 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/05/06 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-84 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.000 0.000 0.046 0.000 0.041 0.000 0.000 0.000 0.088 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.000 0.000 0.000 0.082 0.112 0.000 0.000 0.193 SW 0.000 0.000 0.000 0.000 0.000 0.042 0.000 0.000 0.000 0.042 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.046 0.000 0.164 0.112 0.000 0.000 0.322 TOTAL HOURS OF VALID OBSERVATIONS 2159.000 TOTAL HOURS OF ELEVATED RELEASES 1832.270 TOTAL HOURS OF STABILITY CLASS A 13.570 TOTAL HOURS OF ELEVATED STABILITY CLASS A 6.960 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/05/06 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-85 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.118 0.000 0.000 0.000 0.118 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.044 0.041 0.000 0.000 0.000 0.086 SE 0.000 0.000 0.000 0.046 0.044 0.042 0.000 0.000 0.000 0.133 SSE 0.000 0.000 0.000 0.000 0.089 0.000 0.000 0.000 0.000 0.089 S 0.000 0.000 0.000 0.000 0.000 0.041 0.000 0.000 0.000 0.041 SSW 0.000 0.000 0.000 0.000 0.045 0.000 0.112 0.000 0.000 0.157 SW 0.000 0.000 0.000 0.046 0.091 0.039 0.000 0.000 0.000 0.176 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.082 0.038 0.000 0.000 0.121 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.093 0.314 0.364 0.150 0.000 0.000 0.920 TOTAL HOURS OF VALID OBSERVATIONS 2159.000 TOTAL HOURS OF ELEVATED RELEASES 1832.270 TOTAL HOURS OF STABILITY CLASS B 27.510 TOTAL HOURS OF ELEVATED STABILITY CLASS B 19.870 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/05/06 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-86 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.120 0.076 0.000 0.000 0.196 NNE 0.000 0.000 0.000 0.000 0.000 0.157 0.000 0.000 0.000 0.157 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 ESE 0.000 0.000 0.000 0.046 0.132 0.042 0.000 0.000 0.000 0.220 SE 0.000 0.000 0.000 0.093 0.089 0.000 0.000 0.000 0.000 0.182 SSE 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.091 S 0.000 0.000 0.000 0.093 0.000 0.040 0.000 0.000 0.000 0.133 SSW 0.000 0.000 0.046 0.000 0.045 0.000 0.112 0.028 0.000 0.232 SW 0.000 0.000 0.000 0.000 0.046 0.041 0.000 0.000 0.000 0.087 WSW 0.000 0.000 0.000 0.000 0.044 0.082 0.000 0.000 0.000 0.126 W 0.000 0.000 0.000 0.000 0.044 0.039 0.000 0.000 0.000 0.083 WNW 0.000 0.000 0.000 0.000 0.000 0.161 0.376 0.151 0.000 0.687 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.151 0.029 0.000 0.180 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.149 0.000 0.000 0.149 SUBTOTAL 0.000 0.000 0.046 0.232 0.538 0.681 0.863 0.208 0.000 2.568 TOTAL HOURS OF VALID OBSERVATIONS 2159.000 TOTAL HOURS OF ELEVATED RELEASES 1832.270 TOTAL HOURS OF STABILITY CLASS C 65.970 TOTAL HOURS OF ELEVATED STABILITY CLASS C 55.450 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/05/06 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-87 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.093 0.278 0.402 1.093 0.535 0.000 0.000 2.400 NNE 0.000 0.000 0.139 0.232 0.620 0.890 0.532 0.000 0.000 2.413 NE 0.000 0.000 0.046 0.324 0.445 0.736 0.077 0.000 0.000 1.629 ENE 0.000 0.000 0.046 0.648 0.446 0.456 0.000 0.000 0.000 1.596 E 0.000 0.000 0.139 0.278 0.400 0.249 0.000 0.000 0.000 1.066 ESE 0.000 0.000 0.000 0.324 0.359 0.369 0.076 0.000 0.000 1.128 SE 0.000 0.000 0.278 0.463 0.090 0.609 0.529 0.186 0.000 2.155 SSE 0.000 0.000 0.093 0.324 0.136 0.156 0.413 0.128 0.000 1.250 S 0.000 0.000 0.185 0.232 0.227 0.279 0.376 0.189 0.006 1.493 SSW 0.000 0.000 0.232 0.093 0.092 0.448 0.413 0.190 0.000 1.468 SW 0.000 0.000 0.046 0.139 0.179 0.325 0.075 0.000 0.000 0.764 WSW 0.000 0.000 0.093 0.324 0.362 0.493 0.075 0.119 0.000 1.466 W 0.000 0.000 0.185 0.463 0.442 0.861 0.487 0.121 0.000 2.560 WNW 0.000 0.000 0.093 0.278 0.570 1.220 1.494 0.596 0.010 4.261 NW 0.000 0.000 0.000 0.000 0.397 1.821 2.628 0.444 0.011 5.300 NNW 0.000 0.000 0.000 0.371 0.576 1.704 1.437 0.418 0.020 4.525 SUBTOTAL 0.000 0.000 1.667 4.771 5.742 11.708 9.146 2.390 0.048 35.473 TOTAL HOURS OF VALID OBSERVATIONS 2159.000 TOTAL HOURS OF ELEVATED RELEASES 1832.270 TOTAL HOURS OF STABILITY CLASS D 871.620 TOTAL HOURS OF ELEVATED STABILITY CLASS D 765.860 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/05/06 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-88 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.463 0.266 0.804 0.341 0.028 0.000 1.902 NNE 0.000 0.000 0.046 0.278 0.314 0.843 0.113 0.030 0.000 1.625 NE 0.000 0.000 0.093 0.232 0.492 0.456 0.076 0.000 0.000 1.349 ENE 0.000 0.000 0.046 0.371 0.496 0.290 0.037 0.037 0.000 1.277 E 0.000 0.000 0.046 0.278 0.176 0.417 0.000 0.000 0.000 0.918 ESE 0.000 0.000 0.000 0.278 0.444 1.107 0.227 0.033 0.000 2.088 SE 0.000 0.000 0.000 0.139 0.221 1.358 0.758 0.119 0.008 2.604 SSE 0.000 0.000 0.139 0.046 0.354 1.114 1.127 0.665 0.041 3.487 S 0.000 0.046 0.046 0.185 0.267 0.895 1.015 1.115 0.020 3.590 SSW 0.000 0.000 0.046 0.139 0.222 1.375 1.314 0.544 0.013 3.653 SW 0.000 0.000 0.278 0.417 0.450 0.939 0.038 0.061 0.000 2.182 WSW 0.000 0.046 0.093 0.139 0.399 0.584 0.037 0.000 0.000 1.298 W 0.000 0.000 0.046 0.278 0.535 0.414 0.114 0.000 0.000 1.388 WNW 0.000 0.000 0.046 0.185 0.266 0.080 0.152 0.000 0.000 0.730 NW 0.000 0.000 0.000 0.139 0.176 1.197 0.648 0.000 0.000 2.160 NNW 0.000 0.000 0.000 0.324 0.360 1.800 0.343 0.000 0.000 2.827 SUBTOTAL 0.000 0.093 0.926 3.891 5.439 13.674 6.342 2.631 0.082 33.077 TOTAL HOURS OF VALID OBSERVATIONS 2159.000 TOTAL HOURS OF ELEVATED RELEASES 1832.270 TOTAL HOURS OF STABILITY CLASS E 811.390 TOTAL HOURS OF ELEVATED STABILITY CLASS E 714.140 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/05/06 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-89 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.046 0.046 0.263 0.287 0.113 0.000 0.000 0.756 NNE 0.000 0.000 0.000 0.000 0.138 0.527 0.153 0.000 0.000 0.818 NE 0.000 0.000 0.000 0.000 0.000 0.205 0.000 0.000 0.000 0.205 ENE 0.000 0.000 0.000 0.093 0.044 0.083 0.000 0.000 0.000 0.220 E 0.000 0.000 0.139 0.093 0.219 0.208 0.000 0.000 0.000 0.659 ESE 0.000 0.046 0.093 0.000 0.045 0.120 0.000 0.000 0.000 0.304 SE 0.000 0.046 0.232 0.185 0.044 0.526 0.300 0.086 0.000 1.419 SSE 0.000 0.000 0.093 0.046 0.043 0.845 0.822 0.255 0.019 2.122 S 0.000 0.000 0.139 0.046 0.046 0.723 0.869 0.375 0.001 2.200 SSW 0.000 0.000 0.046 0.093 0.000 0.324 0.038 0.037 0.000 0.537 SW 0.000 0.000 0.046 0.093 0.000 0.040 0.000 0.000 0.000 0.179 WSW 0.000 0.000 0.139 0.093 0.000 0.000 0.000 0.000 0.000 0.232 W 0.000 0.000 0.093 0.000 0.000 0.041 0.000 0.000 0.000 0.134 WNW 0.000 0.000 0.046 0.139 0.132 0.000 0.000 0.000 0.000 0.318 NW 0.000 0.000 0.139 0.046 0.089 0.165 0.000 0.000 0.000 0.440 NNW 0.000 0.000 0.046 0.046 0.223 0.207 0.076 0.000 0.000 0.599 SUBTOTAL 0.000 0.093 1.297 1.019 1.287 4.302 2.372 0.753 0.020 11.142 TOTAL HOURS OF VALID OBSERVATIONS 2159.000 TOTAL HOURS OF ELEVATED RELEASES 1832.270 TOTAL HOURS OF STABILITY CLASS F 303.450 TOTAL HOURS OF ELEVATED STABILITY CLASS F 240.560 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/05/06 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-90 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNE 0.000 0.000 0.000 0.000 0.000 0.078 0.000 0.000 0.000 0.078 NE 0.000 0.000 0.000 0.046 0.000 0.040 0.000 0.000 0.000 0.087 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.046 0.046 0.164 0.000 0.000 0.000 0.256 SSE 0.000 0.000 0.000 0.000 0.046 0.042 0.260 0.067 0.000 0.415 S 0.000 0.000 0.000 0.046 0.000 0.000 0.113 0.000 0.000 0.160 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 WSW 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 W 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 WNW 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 NW 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 NNW 0.000 0.000 0.046 0.000 0.043 0.000 0.000 0.000 0.000 0.089 SUBTOTAL 0.000 0.046 0.185 0.185 0.181 0.324 0.374 0.067 0.000 1.363 TOTAL HOURS OF VALID OBSERVATIONS 2159.000 TOTAL HOURS OF ELEVATED RELEASES 1832.270 TOTAL HOURS OF STABILITY CLASS G 65.490 TOTAL HOURS OF ELEVATED STABILITY CLASS G 29.430 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/05/06 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-91 BROWNS FERRY NUCLEAR PLANT 2016 METEOROLOGICAL DATA TABLE 8B JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL RELEASE MODE AND ELEVATED RELEASE MODE)

SECOND QUARTER

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-92 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.009 0.051 0.000 0.000 0.000 0.060 NNE 0.000 0.000 0.000 0.000 0.009 0.040 0.000 0.000 0.000 0.048 NE 0.000 0.000 0.000 0.000 0.004 0.017 0.000 0.000 0.000 0.021 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.018 0.032 0.124 0.000 0.000 0.000 0.000 0.174 SE 0.000 0.000 0.017 0.137 0.060 0.000 0.000 0.000 0.000 0.214 SSE 0.000 0.000 0.044 0.028 0.000 0.000 0.000 0.000 0.000 0.072 S 0.000 0.000 0.112 0.082 0.043 0.000 0.000 0.000 0.000 0.238 SSW 0.000 0.000 0.040 0.080 0.000 0.000 0.000 0.000 0.000 0.120 SW 0.000 0.000 0.005 0.022 0.000 0.000 0.000 0.000 0.000 0.027 WSW 0.000 0.000 0.000 0.027 0.005 0.000 0.000 0.000 0.000 0.032 W 0.000 0.000 0.000 0.004 0.049 0.036 0.000 0.000 0.000 0.090 WNW 0.000 0.000 0.000 0.000 0.000 0.024 0.030 0.000 0.000 0.053 NW 0.000 0.000 0.000 0.003 0.004 0.029 0.154 0.033 0.000 0.224 NNW 0.000 0.000 0.000 0.000 0.010 0.045 0.000 0.000 0.000 0.055 SUBTOTAL 0.000 0.000 0.236 0.417 0.317 0.242 0.184 0.033 0.000 1.430 TOTAL HOURS OF VALID OBSERVATIONS 2098.000 TOTAL HOURS OF GROUND LEVEL RELEASE 192.540 TOTAL HOURS OF STABILITY CLASS A 65.640 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS A 30.000 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/08/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-93 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.028 0.033 0.000 0.000 0.000 0.061 NNE 0.000 0.000 0.000 0.000 0.017 0.022 0.000 0.000 0.000 0.039 NE 0.000 0.000 0.000 0.000 0.019 0.031 0.000 0.000 0.000 0.049 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.006 0.011 0.009 0.000 0.000 0.000 0.000 0.026 SE 0.000 0.000 0.013 0.011 0.008 0.000 0.000 0.000 0.000 0.032 SSE 0.000 0.000 0.004 0.000 0.000 0.000 0.000 0.000 0.000 0.004 S 0.000 0.000 0.023 0.051 0.000 0.000 0.000 0.000 0.000 0.075 SSW 0.000 0.000 0.042 0.010 0.000 0.000 0.000 0.000 0.000 0.052 SW 0.000 0.000 0.004 0.002 0.000 0.000 0.000 0.000 0.000 0.006 WSW 0.000 0.000 0.000 0.008 0.007 0.000 0.000 0.000 0.000 0.015 W 0.000 0.000 0.000 0.002 0.016 0.022 0.000 0.000 0.000 0.040 WNW 0.000 0.000 0.000 0.000 0.000 0.059 0.063 0.000 0.000 0.122 NW 0.000 0.000 0.000 0.000 0.022 0.042 0.029 0.000 0.000 0.092 NNW 0.000 0.000 0.000 0.000 0.011 0.084 0.027 0.000 0.000 0.123 SUBTOTAL 0.000 0.000 0.092 0.095 0.136 0.294 0.119 0.000 0.000 0.737 TOTAL HOURS OF VALID OBSERVATIONS 2098.000 TOTAL HOURS OF GROUND LEVEL RELEASE 192.540 TOTAL HOURS OF STABILITY CLASS B 116.280 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS B 15.460 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/08/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-94 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.010 0.015 0.000 0.000 0.000 0.025 NNE 0.000 0.000 0.000 0.000 0.005 0.015 0.000 0.000 0.000 0.020 NE 0.000 0.000 0.000 0.005 0.008 0.008 0.000 0.000 0.000 0.021 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.005 0.002 0.000 0.000 0.000 0.000 0.000 0.007 ESE 0.000 0.000 0.000 0.008 0.000 0.000 0.000 0.000 0.000 0.008 SE 0.000 0.000 0.005 0.004 0.000 0.000 0.000 0.000 0.000 0.009 SSE 0.000 0.000 0.011 0.042 0.000 0.000 0.000 0.000 0.000 0.053 S 0.000 0.000 0.016 0.000 0.000 0.000 0.000 0.000 0.000 0.016 SSW 0.000 0.000 0.010 0.019 0.000 0.000 0.000 0.000 0.000 0.028 SW 0.000 0.000 0.011 0.005 0.000 0.000 0.000 0.000 0.000 0.017 WSW 0.000 0.000 0.000 0.013 0.000 0.000 0.000 0.000 0.000 0.013 W 0.000 0.000 0.000 0.003 0.045 0.025 0.000 0.000 0.000 0.073 WNW 0.000 0.000 0.000 0.000 0.010 0.072 0.075 0.000 0.000 0.158 NW 0.000 0.000 0.000 0.000 0.018 0.094 0.000 0.000 0.000 0.112 NNW 0.000 0.000 0.000 0.000 0.027 0.063 0.010 0.000 0.000 0.100 SUBTOTAL 0.000 0.000 0.059 0.102 0.122 0.292 0.085 0.000 0.000 0.660 TOTAL HOURS OF VALID OBSERVATIONS 2098.000 TOTAL HOURS OF GROUND LEVEL RELEASE 192.540 TOTAL HOURS OF STABILITY CLASS C 189.570 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS C 13.840 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/08/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-95 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.003 0.010 0.083 0.041 0.000 0.000 0.000 0.137 NNE 0.000 0.000 0.000 0.019 0.033 0.029 0.000 0.000 0.000 0.081 NE 0.000 0.000 0.000 0.004 0.017 0.000 0.000 0.000 0.000 0.021 ENE 0.000 0.000 0.000 0.002 0.006 0.000 0.000 0.000 0.000 0.008 E 0.000 0.000 0.000 0.016 0.006 0.000 0.000 0.000 0.000 0.022 ESE 0.000 0.000 0.031 0.074 0.122 0.010 0.000 0.000 0.000 0.237 SE 0.000 0.000 0.045 0.100 0.040 0.000 0.000 0.000 0.000 0.185 SSE 0.000 0.000 0.055 0.039 0.000 0.000 0.000 0.000 0.000 0.094 S 0.000 0.000 0.120 0.081 0.041 0.000 0.000 0.000 0.000 0.242 SSW 0.000 0.000 0.227 0.074 0.000 0.000 0.000 0.000 0.000 0.301 SW 0.000 0.000 0.040 0.000 0.000 0.000 0.000 0.000 0.000 0.040 WSW 0.000 0.000 0.016 0.039 0.007 0.010 0.000 0.000 0.000 0.071 W 0.000 0.000 0.000 0.073 0.087 0.047 0.000 0.000 0.000 0.207 WNW 0.000 0.000 0.000 0.004 0.038 0.235 0.067 0.000 0.000 0.343 NW 0.000 0.000 0.000 0.012 0.060 0.228 0.048 0.000 0.000 0.348 NNW 0.000 0.000 0.000 0.010 0.074 0.061 0.020 0.000 0.000 0.164 SUBTOTAL 0.000 0.000 0.536 0.558 0.614 0.660 0.134 0.000 0.000 2.502 TOTAL HOURS OF VALID OBSERVATIONS 2098.000 TOTAL HOURS OF GROUND LEVEL RELEASE 192.540 TOTAL HOURS OF STABILITY CLASS D 783.230 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS D 52.490 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/08/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-96 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.032 0.053 0.024 0.027 0.000 0.000 0.000 0.136 NNE 0.000 0.000 0.012 0.050 0.095 0.000 0.000 0.000 0.000 0.157 NE 0.000 0.003 0.010 0.009 0.020 0.016 0.000 0.000 0.000 0.058 ENE 0.000 0.005 0.008 0.022 0.020 0.000 0.000 0.000 0.000 0.054 E 0.000 0.007 0.106 0.118 0.000 0.000 0.000 0.000 0.000 0.231 ESE 0.000 0.005 0.118 0.178 0.056 0.000 0.000 0.000 0.000 0.357 SE 0.000 0.001 0.082 0.000 0.023 0.000 0.000 0.000 0.000 0.106 SSE 0.000 0.004 0.111 0.000 0.000 0.000 0.000 0.000 0.000 0.114 S 0.000 0.007 0.328 0.112 0.073 0.000 0.000 0.000 0.000 0.521 SSW 0.000 0.000 0.156 0.020 0.000 0.000 0.000 0.000 0.000 0.176 SW 0.000 0.001 0.014 0.000 0.000 0.000 0.000 0.000 0.000 0.016 WSW 0.000 0.000 0.016 0.010 0.009 0.000 0.000 0.000 0.000 0.035 W 0.000 0.000 0.017 0.065 0.037 0.024 0.000 0.000 0.000 0.143 WNW 0.000 0.000 0.000 0.013 0.023 0.033 0.000 0.000 0.000 0.069 NW 0.000 0.000 0.011 0.024 0.037 0.050 0.000 0.000 0.000 0.123 NNW 0.000 0.000 0.021 0.079 0.080 0.025 0.000 0.000 0.000 0.204 SUBTOTAL 0.000 0.034 1.041 0.755 0.497 0.174 0.000 0.000 0.000 2.501 TOTAL HOURS OF VALID OBSERVATIONS 2098.000 TOTAL HOURS OF GROUND LEVEL RELEASE 192.540 TOTAL HOURS OF STABILITY CLASS E 635.730 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS E 52.470 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/08/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-97 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.160 0.093 0.009 0.000 0.000 0.000 0.000 0.262 NNE 0.000 0.000 0.026 0.041 0.000 0.000 0.000 0.000 0.000 0.067 NE 0.000 0.010 0.006 0.020 0.015 0.000 0.000 0.000 0.000 0.051 ENE 0.000 0.010 0.020 0.033 0.000 0.000 0.000 0.000 0.000 0.062 E 0.000 0.032 0.052 0.032 0.000 0.000 0.000 0.000 0.000 0.116 ESE 0.000 0.010 0.055 0.021 0.010 0.000 0.000 0.000 0.000 0.096 SE 0.000 0.033 0.028 0.000 0.000 0.000 0.000 0.000 0.000 0.061 SSE 0.000 0.029 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.037 S 0.000 0.006 0.150 0.000 0.000 0.000 0.000 0.000 0.000 0.156 SSW 0.000 0.000 0.013 0.000 0.000 0.000 0.000 0.000 0.000 0.013 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.001 WNW 0.000 0.007 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.009 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.064 0.080 0.009 0.000 0.000 0.000 0.000 0.152 SUBTOTAL 0.000 0.137 0.584 0.321 0.041 0.000 0.000 0.000 0.000 1.084 TOTAL HOURS OF VALID OBSERVATIONS 2098.000 TOTAL HOURS OF GROUND LEVEL RELEASE 192.540 TOTAL HOURS OF STABILITY CLASS F 227.990 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS F 22.740 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/08/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-98 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.003 0.083 0.038 0.000 0.000 0.000 0.000 0.000 0.124 NNE 0.000 0.012 0.012 0.012 0.000 0.000 0.000 0.000 0.000 0.037 NE 0.000 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 ENE 0.000 0.011 0.003 0.013 0.000 0.000 0.000 0.000 0.000 0.027 E 0.000 0.012 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.018 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.002 SSE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 S 0.000 0.000 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.010 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.005 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 NNW 0.000 0.000 0.038 0.000 0.000 0.000 0.000 0.000 0.000 0.038 SUBTOTAL 0.000 0.041 0.159 0.063 0.000 0.000 0.000 0.000 0.000 0.264 TOTAL HOURS OF VALID OBSERVATIONS 2098.000 TOTAL HOURS OF GROUND LEVEL RELEASE 192.540 TOTAL HOURS OF STABILITY CLASS G 79.560 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS G 5.540 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/08/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-99 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.044 0.165 0.078 0.000 0.000 0.288 SSE 0.000 0.000 0.000 0.048 0.135 0.122 0.115 0.038 0.000 0.458 S 0.000 0.000 0.000 0.000 0.091 0.211 0.000 0.000 0.000 0.301 SSW 0.000 0.000 0.000 0.000 0.000 0.083 0.000 0.000 0.000 0.083 SW 0.000 0.000 0.000 0.000 0.044 0.000 0.000 0.000 0.000 0.044 WSW 0.000 0.000 0.000 0.048 0.140 0.127 0.000 0.000 0.000 0.315 W 0.000 0.000 0.000 0.000 0.045 0.126 0.000 0.000 0.000 0.172 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.038 0.000 0.000 0.038 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.095 0.499 0.836 0.231 0.038 0.000 1.699 TOTAL HOURS OF VALID OBSERVATIONS 2098.000 TOTAL HOURS OF ELEVATED RELEASES 1905.460 TOTAL HOURS OF STABILITY CLASS A 65.640 TOTAL HOURS OF ELEVATED STABILITY CLASS A 35.640 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/08/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-100 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.125 0.040 0.000 0.000 0.165 NNE 0.000 0.000 0.000 0.000 0.045 0.082 0.000 0.000 0.000 0.127 NE 0.000 0.000 0.000 0.000 0.000 0.084 0.000 0.000 0.000 0.084 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.041 0.000 0.000 0.000 0.041 SE 0.000 0.000 0.000 0.000 0.094 0.120 0.428 0.000 0.000 0.642 SSE 0.000 0.000 0.000 0.143 0.047 0.082 0.038 0.000 0.000 0.309 S 0.000 0.000 0.000 0.143 0.092 0.292 0.311 0.000 0.000 0.838 SSW 0.000 0.000 0.000 0.238 0.230 0.384 0.000 0.000 0.000 0.853 SW 0.000 0.000 0.000 0.191 0.139 0.044 0.000 0.000 0.000 0.374 WSW 0.000 0.000 0.000 0.143 0.091 0.000 0.000 0.000 0.000 0.234 W 0.000 0.000 0.000 0.048 0.046 0.459 0.079 0.000 0.000 0.632 WNW 0.000 0.000 0.000 0.000 0.000 0.042 0.114 0.000 0.000 0.156 NW 0.000 0.000 0.000 0.000 0.000 0.041 0.116 0.032 0.000 0.189 NNW 0.000 0.000 0.000 0.000 0.000 0.125 0.039 0.000 0.000 0.163 SUBTOTAL 0.000 0.000 0.000 0.906 0.784 1.920 1.164 0.032 0.000 4.806 TOTAL HOURS OF VALID OBSERVATIONS 2098.000 TOTAL HOURS OF ELEVATED RELEASES 1905.460 TOTAL HOURS OF STABILITY CLASS B 116.280 TOTAL HOURS OF ELEVATED STABILITY CLASS B 100.820 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/08/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-101 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.091 0.778 0.000 0.000 0.000 0.869 NNE 0.000 0.000 0.000 0.000 0.044 0.632 0.040 0.000 0.000 0.716 NE 0.000 0.000 0.000 0.000 0.046 0.084 0.000 0.000 0.000 0.130 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.038 0.000 0.000 0.038 SE 0.000 0.000 0.000 0.143 0.279 0.462 0.231 0.000 0.000 1.115 SSE 0.000 0.000 0.048 0.095 0.048 0.084 0.000 0.000 0.000 0.275 S 0.000 0.000 0.048 0.286 0.180 0.121 0.155 0.000 0.004 0.794 SSW 0.000 0.000 0.000 0.334 0.047 0.295 0.000 0.000 0.000 0.675 SW 0.000 0.000 0.048 0.238 0.187 0.170 0.000 0.000 0.000 0.643 WSW 0.000 0.000 0.048 0.191 0.140 0.254 0.000 0.000 0.000 0.632 W 0.000 0.000 0.000 0.095 0.274 0.163 0.040 0.000 0.000 0.572 WNW 0.000 0.000 0.000 0.000 0.045 0.123 0.580 0.079 0.000 0.826 NW 0.000 0.000 0.000 0.000 0.000 0.340 0.268 0.055 0.000 0.663 NNW 0.000 0.000 0.000 0.000 0.000 0.289 0.077 0.061 0.000 0.428 SUBTOTAL 0.000 0.000 0.191 1.382 1.380 3.796 1.428 0.194 0.004 8.376 TOTAL HOURS OF VALID OBSERVATIONS 2098.000 TOTAL HOURS OF ELEVATED RELEASES 1905.460 TOTAL HOURS OF STABILITY CLASS C 189.570 TOTAL HOURS OF ELEVATED STABILITY CLASS C 175.730 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/08/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-102 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.048 0.286 0.552 1.041 0.235 0.000 0.000 2.161 NNE 0.000 0.048 0.000 0.191 0.319 0.502 0.118 0.000 0.000 1.178 NE 0.000 0.000 0.048 0.143 0.231 0.215 0.000 0.000 0.000 0.636 ENE 0.000 0.000 0.143 0.000 0.092 0.042 0.000 0.000 0.000 0.277 E 0.000 0.000 0.095 0.191 0.181 0.171 0.000 0.000 0.000 0.638 ESE 0.000 0.000 0.048 0.429 0.136 0.379 0.118 0.000 0.000 1.111 SE 0.000 0.000 0.477 1.001 0.417 0.835 1.007 0.100 0.000 3.835 SSE 0.000 0.000 0.524 0.572 0.415 0.798 0.619 0.130 0.000 3.059 S 0.000 0.000 0.191 0.572 0.505 1.253 1.169 0.086 0.017 3.792 SSW 0.000 0.000 0.286 0.524 1.063 1.266 0.504 0.000 0.000 3.643 SW 0.000 0.000 0.381 0.620 0.462 0.168 0.000 0.000 0.000 1.631 WSW 0.000 0.048 0.095 0.620 0.688 0.337 0.039 0.038 0.000 1.864 W 0.000 0.000 0.000 0.858 0.910 1.134 0.116 0.000 0.000 3.018 WNW 0.000 0.000 0.000 0.286 0.455 1.524 0.660 0.095 0.000 3.021 NW 0.000 0.000 0.095 0.095 0.227 1.387 1.095 0.000 0.000 2.900 NNW 0.000 0.000 0.048 0.143 0.276 1.339 0.195 0.065 0.000 2.067 SUBTOTAL 0.000 0.095 2.479 6.530 6.931 12.389 5.875 0.514 0.017 34.830 TOTAL HOURS OF VALID OBSERVATIONS 2098.000 TOTAL HOURS OF ELEVATED RELEASES 1905.460 TOTAL HOURS OF STABILITY CLASS D 783.230 TOTAL HOURS OF ELEVATED STABILITY CLASS D 730.740 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/08/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-103 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.095 0.191 0.094 0.956 0.194 0.000 0.000 1.531 NNE 0.000 0.000 0.095 0.286 0.407 1.088 0.156 0.000 0.000 2.032 NE 0.000 0.000 0.095 0.000 0.235 0.292 0.040 0.000 0.000 0.661 ENE 0.000 0.000 0.095 0.191 0.182 0.251 0.000 0.000 0.000 0.719 E 0.000 0.000 0.048 0.191 0.323 0.168 0.000 0.000 0.000 0.729 ESE 0.000 0.000 0.238 0.524 0.735 1.298 0.000 0.000 0.000 2.796 SE 0.000 0.000 0.191 0.477 0.368 0.969 0.156 0.038 0.000 2.198 SSE 0.000 0.000 0.286 0.334 0.644 0.787 0.431 0.086 0.000 2.568 S 0.000 0.000 0.143 0.477 0.553 1.375 0.859 0.041 0.009 3.457 SSW 0.000 0.000 0.095 0.524 0.699 1.285 0.118 0.000 0.000 2.721 SW 0.000 0.000 0.191 0.906 0.328 0.000 0.039 0.000 0.000 1.464 WSW 0.000 0.000 0.191 0.381 0.506 0.215 0.000 0.000 0.000 1.293 W 0.000 0.000 0.048 0.477 0.781 0.684 0.039 0.000 0.000 2.029 WNW 0.000 0.000 0.048 0.191 0.180 0.210 0.078 0.000 0.000 0.705 NW 0.000 0.000 0.048 0.143 0.093 0.500 0.236 0.000 0.000 1.020 NNW 0.000 0.000 0.048 0.238 0.274 1.082 0.235 0.000 0.000 1.878 SUBTOTAL 0.000 0.000 1.954 5.529 6.402 11.161 2.581 0.165 0.009 27.801 TOTAL HOURS OF VALID OBSERVATIONS 2098.000 TOTAL HOURS OF ELEVATED RELEASES 1905.460 TOTAL HOURS OF STABILITY CLASS E 635.730 TOTAL HOURS OF ELEVATED STABILITY CLASS E 583.260 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/08/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-104 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.048 0.046 1.078 0.079 0.000 0.000 1.250 NNE 0.000 0.000 0.048 0.048 0.142 0.671 0.040 0.000 0.000 0.948 NE 0.000 0.048 0.143 0.143 0.232 0.327 0.000 0.000 0.000 0.893 ENE 0.000 0.000 0.095 0.143 0.092 0.126 0.000 0.000 0.000 0.457 E 0.000 0.000 0.095 0.238 0.136 0.166 0.000 0.000 0.000 0.636 ESE 0.000 0.000 0.048 0.238 0.186 0.214 0.000 0.000 0.000 0.686 SE 0.000 0.000 0.095 0.191 0.143 0.169 0.000 0.000 0.000 0.598 SSE 0.000 0.000 0.095 0.048 0.091 0.130 0.000 0.029 0.000 0.392 S 0.000 0.000 0.095 0.000 0.228 0.587 0.038 0.000 0.000 0.949 SSW 0.000 0.000 0.095 0.048 0.089 0.206 0.000 0.000 0.000 0.439 SW 0.000 0.000 0.000 0.143 0.000 0.000 0.000 0.000 0.000 0.143 WSW 0.000 0.000 0.191 0.095 0.000 0.000 0.000 0.000 0.000 0.286 W 0.000 0.000 0.143 0.286 0.190 0.000 0.000 0.000 0.000 0.619 WNW 0.000 0.048 0.000 0.143 0.046 0.042 0.000 0.000 0.000 0.279 NW 0.000 0.000 0.000 0.000 0.134 0.382 0.000 0.000 0.000 0.517 NNW 0.000 0.000 0.000 0.143 0.091 0.460 0.000 0.000 0.000 0.694 SUBTOTAL 0.000 0.095 1.144 1.954 1.847 4.558 0.156 0.029 0.000 9.783 TOTAL HOURS OF VALID OBSERVATIONS 2098.000 TOTAL HOURS OF ELEVATED RELEASES 1905.460 TOTAL HOURS OF STABILITY CLASS F 227.990 TOTAL HOURS OF ELEVATED STABILITY CLASS F 205.250 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/08/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-105 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.048 0.047 0.122 0.000 0.000 0.000 0.217 NNE 0.000 0.000 0.048 0.000 0.045 0.375 0.000 0.000 0.000 0.468 NE 0.000 0.000 0.048 0.143 0.231 0.214 0.000 0.000 0.000 0.636 ENE 0.000 0.000 0.000 0.095 0.048 0.000 0.000 0.000 0.000 0.143 E 0.000 0.000 0.048 0.048 0.045 0.044 0.000 0.000 0.000 0.184 ESE 0.000 0.000 0.048 0.095 0.094 0.000 0.000 0.000 0.000 0.237 SE 0.000 0.000 0.191 0.334 0.275 0.000 0.000 0.000 0.000 0.799 SSE 0.000 0.000 0.000 0.143 0.000 0.044 0.000 0.000 0.000 0.187 S 0.000 0.000 0.095 0.048 0.046 0.000 0.000 0.000 0.000 0.189 SSW 0.000 0.048 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.095 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.048 0.143 0.000 0.000 0.000 0.000 0.000 0.000 0.191 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.042 0.000 0.000 0.000 0.042 NNW 0.000 0.000 0.048 0.000 0.092 0.000 0.000 0.000 0.000 0.140 SUBTOTAL 0.000 0.095 0.715 0.953 0.923 0.841 0.000 0.000 0.000 3.528 TOTAL HOURS OF VALID OBSERVATIONS 2098.000 TOTAL HOURS OF ELEVATED RELEASES 1905.460 TOTAL HOURS OF STABILITY CLASS G 79.560 TOTAL HOURS OF ELEVATED STABILITY CLASS G 74.020 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2016/08/05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-106 BROWNS FERRY NUCLEAR PLANT 2016 METEOROLOGICAL DATA TABLE 8C JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL RELEASE MODE AND ELEVATED RELEASE MODE)

THIRD QUARTER

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-107 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.040 0.120 0.000 0.000 0.000 0.159 NNE 0.000 0.000 0.000 0.000 0.016 0.034 0.000 0.000 0.000 0.050 NE 0.000 0.000 0.000 0.000 0.003 0.035 0.000 0.000 0.000 0.038 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.009 ESE 0.000 0.000 0.005 0.055 0.039 0.008 0.000 0.000 0.000 0.107 SE 0.000 0.000 0.043 0.091 0.000 0.000 0.000 0.000 0.000 0.134 SSE 0.000 0.000 0.059 0.038 0.000 0.000 0.000 0.000 0.000 0.097 S 0.000 0.000 0.104 0.025 0.000 0.000 0.000 0.000 0.000 0.129 SSW 0.000 0.000 0.044 0.037 0.000 0.000 0.000 0.000 0.000 0.082 SW 0.000 0.000 0.003 0.003 0.000 0.000 0.000 0.000 0.000 0.005 WSW 0.000 0.000 0.005 0.059 0.048 0.008 0.000 0.000 0.000 0.120 W 0.000 0.000 0.000 0.009 0.052 0.032 0.000 0.000 0.000 0.093 WNW 0.000 0.000 0.002 0.000 0.010 0.056 0.000 0.000 0.000 0.067 NW 0.000 0.000 0.000 0.000 0.008 0.039 0.000 0.000 0.000 0.047 NNW 0.000 0.000 0.000 0.000 0.011 0.057 0.000 0.000 0.000 0.068 SUBTOTAL 0.000 0.000 0.265 0.327 0.226 0.388 0.000 0.000 0.000 1.206 TOTAL HOURS OF VALID OBSERVATIONS 2189.000 TOTAL HOURS OF GROUND LEVEL RELEASE 134.070 TOTAL HOURS OF STABILITY CLASS A 72.550 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS A 26.390 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/10 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-108 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.009 0.021 0.012 0.000 0.000 0.000 0.042 NNE 0.000 0.000 0.000 0.000 0.005 0.000 0.000 0.000 0.000 0.005 NE 0.000 0.000 0.000 0.001 0.005 0.000 0.000 0.000 0.000 0.006 ENE 0.000 0.000 0.000 0.001 0.000 0.000 0.000 0.000 0.000 0.001 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.016 0.022 0.012 0.000 0.000 0.000 0.000 0.050 SE 0.000 0.000 0.022 0.020 0.000 0.000 0.000 0.000 0.000 0.042 SSE 0.000 0.000 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.001 S 0.000 0.000 0.016 0.000 0.000 0.000 0.000 0.000 0.000 0.016 SSW 0.000 0.000 0.012 0.014 0.000 0.000 0.000 0.000 0.000 0.026 SW 0.000 0.000 0.000 0.004 0.000 0.000 0.000 0.000 0.000 0.004 WSW 0.000 0.000 0.000 0.021 0.034 0.000 0.000 0.000 0.000 0.055 W 0.000 0.000 0.000 0.010 0.037 0.014 0.000 0.000 0.000 0.061 WNW 0.000 0.000 0.000 0.000 0.010 0.041 0.000 0.000 0.000 0.051 NW 0.000 0.000 0.000 0.000 0.007 0.017 0.000 0.000 0.000 0.024 NNW 0.000 0.000 0.000 0.000 0.002 0.014 0.000 0.000 0.000 0.016 SUBTOTAL 0.000 0.000 0.068 0.102 0.133 0.099 0.000 0.000 0.000 0.402 TOTAL HOURS OF VALID OBSERVATIONS 2189.000 TOTAL HOURS OF GROUND LEVEL RELEASE 134.070 TOTAL HOURS OF STABILITY CLASS B 96.890 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS B 8.790 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/10 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-109 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.003 0.004 0.008 0.000 0.000 0.000 0.015 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.002 0.010 0.012 0.000 0.000 0.000 0.024 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.005 0.000 0.000 0.000 0.000 0.005 ESE 0.000 0.000 0.000 0.046 0.015 0.000 0.000 0.000 0.000 0.061 SE 0.000 0.000 0.010 0.002 0.000 0.000 0.000 0.000 0.000 0.011 SSE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.007 0.015 0.000 0.000 0.000 0.000 0.000 0.022 SW 0.000 0.000 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.005 WSW 0.000 0.000 0.002 0.023 0.011 0.000 0.000 0.000 0.000 0.036 W 0.000 0.000 0.000 0.007 0.035 0.007 0.000 0.000 0.000 0.049 WNW 0.000 0.000 0.000 0.000 0.015 0.023 0.000 0.000 0.000 0.037 NW 0.000 0.000 0.000 0.000 0.009 0.000 0.010 0.000 0.000 0.019 NNW 0.000 0.000 0.000 0.000 0.009 0.008 0.000 0.000 0.000 0.017 SUBTOTAL 0.000 0.000 0.025 0.098 0.113 0.058 0.010 0.000 0.000 0.303 TOTAL HOURS OF VALID OBSERVATIONS 2189.000 TOTAL HOURS OF GROUND LEVEL RELEASE 134.070 TOTAL HOURS OF STABILITY CLASS C 186.470 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS C 6.640 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/10 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-110 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.052 0.042 0.033 0.000 0.000 0.000 0.127 NNE 0.000 0.000 0.000 0.029 0.048 0.022 0.000 0.000 0.000 0.100 NE 0.000 0.000 0.000 0.009 0.032 0.036 0.000 0.000 0.000 0.076 ENE 0.000 0.000 0.000 0.011 0.017 0.000 0.000 0.000 0.000 0.028 E 0.000 0.000 0.008 0.049 0.025 0.000 0.000 0.000 0.000 0.082 ESE 0.000 0.000 0.067 0.174 0.048 0.000 0.000 0.000 0.000 0.289 SE 0.000 0.000 0.078 0.018 0.000 0.000 0.000 0.000 0.000 0.095 SSE 0.000 0.000 0.105 0.000 0.000 0.000 0.000 0.000 0.000 0.105 S 0.000 0.000 0.144 0.009 0.000 0.000 0.000 0.000 0.000 0.153 SSW 0.000 0.000 0.126 0.049 0.000 0.000 0.000 0.000 0.000 0.175 SW 0.000 0.000 0.041 0.000 0.000 0.000 0.000 0.000 0.000 0.041 WSW 0.000 0.000 0.032 0.043 0.027 0.000 0.000 0.000 0.000 0.101 W 0.000 0.000 0.003 0.054 0.051 0.034 0.000 0.000 0.000 0.142 WNW 0.000 0.000 0.000 0.005 0.008 0.059 0.000 0.000 0.000 0.072 NW 0.000 0.000 0.000 0.005 0.003 0.029 0.000 0.000 0.000 0.037 NNW 0.000 0.000 0.000 0.009 0.038 0.047 0.000 0.000 0.000 0.094 SUBTOTAL 0.000 0.000 0.603 0.517 0.339 0.260 0.000 0.000 0.000 1.719 TOTAL HOURS OF VALID OBSERVATIONS 2189.000 TOTAL HOURS OF GROUND LEVEL RELEASE 134.070 TOTAL HOURS OF STABILITY CLASS D 848.250 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS D 37.620 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/10 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-111 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.072 0.122 0.007 0.000 0.000 0.000 0.000 0.201 NNE 0.000 0.000 0.038 0.134 0.065 0.017 0.000 0.000 0.000 0.255 NE 0.000 0.002 0.016 0.074 0.083 0.030 0.000 0.000 0.000 0.205 ENE 0.000 0.000 0.052 0.048 0.013 0.000 0.000 0.000 0.000 0.112 E 0.000 0.002 0.079 0.080 0.021 0.000 0.000 0.000 0.000 0.183 ESE 0.000 0.000 0.087 0.061 0.000 0.000 0.000 0.000 0.000 0.148 SE 0.000 0.007 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.055 SSE 0.000 0.000 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.007 S 0.000 0.005 0.085 0.000 0.000 0.000 0.000 0.000 0.000 0.090 SSW 0.000 0.009 0.088 0.030 0.000 0.000 0.000 0.000 0.000 0.127 SW 0.000 0.000 0.018 0.000 0.000 0.000 0.000 0.000 0.000 0.018 WSW 0.000 0.000 0.001 0.005 0.000 0.000 0.000 0.000 0.000 0.005 W 0.000 0.000 0.004 0.024 0.012 0.000 0.000 0.000 0.000 0.040 WNW 0.000 0.000 0.000 0.000 0.003 0.000 0.000 0.000 0.000 0.003 NW 0.000 0.005 0.000 0.006 0.000 0.006 0.000 0.000 0.000 0.017 NNW 0.000 0.000 0.011 0.045 0.043 0.000 0.000 0.000 0.000 0.100 SUBTOTAL 0.000 0.031 0.608 0.629 0.247 0.053 0.000 0.000 0.000 1.567 TOTAL HOURS OF VALID OBSERVATIONS 2189.000 TOTAL HOURS OF GROUND LEVEL RELEASE 134.070 TOTAL HOURS OF STABILITY CLASS E 630.000 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS E 34.310 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/10 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-112 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.121 0.069 0.000 0.000 0.000 0.000 0.000 0.190 NNE 0.000 0.000 0.079 0.102 0.037 0.000 0.000 0.000 0.000 0.217 NE 0.000 0.000 0.053 0.031 0.007 0.000 0.000 0.000 0.000 0.092 ENE 0.000 0.000 0.047 0.020 0.000 0.000 0.000 0.000 0.000 0.067 E 0.000 0.003 0.072 0.030 0.000 0.000 0.000 0.000 0.000 0.105 ESE 0.000 0.012 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.020 SE 0.000 0.003 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.008 SSE 0.000 0.005 0.003 0.000 0.000 0.000 0.000 0.000 0.000 0.009 S 0.000 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 SSW 0.000 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.007 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.006 W 0.000 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 WNW 0.000 0.000 0.000 0.003 0.000 0.000 0.000 0.000 0.000 0.003 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.002 0.007 0.006 0.000 0.000 0.000 0.000 0.000 0.015 SUBTOTAL 0.000 0.039 0.400 0.261 0.044 0.000 0.000 0.000 0.000 0.744 TOTAL HOURS OF VALID OBSERVATIONS 2189.000 TOTAL HOURS OF GROUND LEVEL RELEASE 134.070 TOTAL HOURS OF STABILITY CLASS F 295.640 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS F 16.290 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/10 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-113 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.005 0.053 0.005 0.000 0.000 0.000 0.000 0.000 0.063 NNE 0.000 0.007 0.025 0.003 0.000 0.000 0.000 0.000 0.000 0.035 NE 0.000 0.008 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.015 ENE 0.000 0.001 0.013 0.005 0.008 0.000 0.000 0.000 0.000 0.027 E 0.000 0.000 0.020 0.000 0.000 0.000 0.000 0.000 0.000 0.021 ESE 0.000 0.000 0.000 0.003 0.000 0.000 0.000 0.000 0.000 0.003 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.005 0.000 0.000 0.000 0.000 0.005 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.003 0.000 0.000 0.000 0.000 0.000 0.000 0.003 NNW 0.000 0.002 0.011 0.000 0.000 0.000 0.000 0.000 0.000 0.014 SUBTOTAL 0.000 0.023 0.132 0.016 0.013 0.000 0.000 0.000 0.000 0.184 TOTAL HOURS OF VALID OBSERVATIONS 2189.000 TOTAL HOURS OF GROUND LEVEL RELEASE 134.070 TOTAL HOURS OF STABILITY CLASS G 59.200 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS G 4.030 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/10 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-114 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.076 0.000 0.000 0.076 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.080 0.000 0.000 0.000 0.080 SE 0.000 0.000 0.000 0.046 0.177 0.196 0.000 0.000 0.000 0.419 SSE 0.000 0.000 0.000 0.091 0.265 0.081 0.151 0.000 0.000 0.588 S 0.000 0.000 0.000 0.046 0.134 0.238 0.000 0.000 0.000 0.418 SSW 0.000 0.000 0.000 0.000 0.045 0.082 0.000 0.000 0.000 0.127 SW 0.000 0.000 0.000 0.000 0.043 0.118 0.075 0.000 0.000 0.236 WSW 0.000 0.000 0.000 0.000 0.042 0.039 0.000 0.000 0.000 0.081 W 0.000 0.000 0.000 0.000 0.043 0.041 0.000 0.000 0.000 0.084 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.183 0.749 0.875 0.302 0.000 0.000 2.109 TOTAL HOURS OF VALID OBSERVATIONS 2189.000 TOTAL HOURS OF ELEVATED RELEASES 2054.930 TOTAL HOURS OF STABILITY CLASS A 72.550 TOTAL HOURS OF ELEVATED STABILITY CLASS A 46.160 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/10 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-115 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.558 0.038 0.000 0.000 0.596 NNE 0.000 0.000 0.000 0.000 0.000 0.157 0.000 0.000 0.000 0.157 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.183 0.266 0.317 0.000 0.000 0.000 0.767 SSE 0.000 0.000 0.000 0.274 0.177 0.082 0.000 0.000 0.000 0.533 S 0.000 0.000 0.000 0.274 0.176 0.077 0.038 0.000 0.000 0.565 SSW 0.000 0.000 0.000 0.046 0.091 0.042 0.000 0.000 0.000 0.179 SW 0.000 0.000 0.000 0.000 0.043 0.204 0.000 0.000 0.000 0.247 WSW 0.000 0.000 0.000 0.000 0.180 0.283 0.076 0.000 0.000 0.539 W 0.000 0.000 0.000 0.000 0.090 0.080 0.000 0.000 0.000 0.170 WNW 0.000 0.000 0.000 0.000 0.044 0.117 0.000 0.000 0.000 0.161 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.075 0.000 0.000 0.075 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.037 0.000 0.000 0.037 SUBTOTAL 0.000 0.000 0.000 0.777 1.067 1.917 0.264 0.000 0.000 4.025 TOTAL HOURS OF VALID OBSERVATIONS 2189.000 TOTAL HOURS OF ELEVATED RELEASES 2054.930 TOTAL HOURS OF STABILITY CLASS B 96.890 TOTAL HOURS OF ELEVATED STABILITY CLASS B 88.100 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/10 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-116 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.174 0.481 0.075 0.000 0.000 0.731 NNE 0.000 0.000 0.000 0.046 0.000 0.206 0.000 0.000 0.000 0.252 NE 0.000 0.000 0.000 0.000 0.043 0.077 0.038 0.000 0.000 0.158 ENE 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.039 0.037 0.000 0.000 0.077 SE 0.000 0.000 0.000 0.228 0.132 0.120 0.150 0.000 0.000 0.630 SSE 0.000 0.000 0.091 0.320 0.354 0.082 0.110 0.000 0.000 0.957 S 0.000 0.000 0.091 0.503 0.219 0.352 0.038 0.000 0.000 1.203 SSW 0.000 0.000 0.091 0.274 0.090 0.042 0.000 0.000 0.000 0.497 SW 0.000 0.000 0.091 0.320 0.132 0.164 0.000 0.000 0.000 0.706 WSW 0.000 0.000 0.000 0.228 0.260 0.515 0.000 0.000 0.000 1.004 W 0.000 0.000 0.000 0.137 0.392 0.371 0.038 0.000 0.000 0.938 WNW 0.000 0.000 0.000 0.000 0.131 0.401 0.038 0.000 0.000 0.570 NW 0.000 0.000 0.000 0.000 0.044 0.322 0.000 0.000 0.000 0.365 NNW 0.000 0.000 0.000 0.000 0.043 0.039 0.000 0.000 0.000 0.083 SUBTOTAL 0.000 0.000 0.411 2.056 2.012 3.211 0.525 0.000 0.000 8.215 TOTAL HOURS OF VALID OBSERVATIONS 2189.000 TOTAL HOURS OF ELEVATED RELEASES 2054.930 TOTAL HOURS OF STABILITY CLASS C 186.470 TOTAL HOURS OF ELEVATED STABILITY CLASS C 179.830 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/10 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-117 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.091 0.228 0.263 1.005 0.263 0.000 0.000 1.851 NNE 0.000 0.000 0.137 0.320 0.178 0.681 0.076 0.000 0.000 1.392 NE 0.000 0.000 0.046 0.137 0.398 0.323 0.076 0.000 0.000 0.979 ENE 0.000 0.000 0.183 0.183 0.133 0.000 0.000 0.000 0.000 0.499 E 0.000 0.000 0.000 0.274 0.090 0.163 0.000 0.000 0.000 0.527 ESE 0.000 0.000 0.000 0.457 0.346 0.816 0.113 0.000 0.000 1.732 SE 0.000 0.000 0.228 1.142 0.531 0.728 0.448 0.035 0.000 3.113 SSE 0.000 0.000 1.096 0.868 0.442 1.395 0.934 0.032 0.000 4.768 S 0.000 0.046 0.868 1.645 1.812 0.918 0.264 0.103 0.000 5.656 SSW 0.000 0.000 0.640 1.827 0.972 0.968 0.187 0.000 0.000 4.594 SW 0.000 0.046 0.868 1.096 0.974 0.576 0.000 0.000 0.000 3.560 WSW 0.000 0.000 0.183 0.868 0.617 0.603 0.037 0.000 0.000 2.308 W 0.000 0.000 0.274 0.685 0.882 0.606 0.038 0.000 0.000 2.485 WNW 0.000 0.046 0.046 0.548 0.478 0.522 0.038 0.000 0.000 1.677 NW 0.000 0.000 0.091 0.183 0.391 0.202 0.037 0.036 0.000 0.941 NNW 0.000 0.000 0.046 0.183 0.175 0.322 0.226 0.000 0.000 0.952 SUBTOTAL 0.000 0.137 4.797 10.644 8.682 9.829 2.736 0.207 0.000 37.032 TOTAL HOURS OF VALID OBSERVATIONS 2189.000 TOTAL HOURS OF ELEVATED RELEASES 2054.930 TOTAL HOURS OF STABILITY CLASS D 848.250 TOTAL HOURS OF ELEVATED STABILITY CLASS D 810.630 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/10 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-118 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.091 0.274 0.228 0.264 1.329 0.188 0.000 0.000 2.375 NNE 0.000 0.000 0.137 0.183 0.527 1.813 0.150 0.000 0.000 2.810 NE 0.000 0.000 0.183 0.411 0.225 1.364 0.114 0.000 0.000 2.296 ENE 0.000 0.000 0.228 0.274 0.354 0.327 0.000 0.000 0.000 1.184 E 0.000 0.000 0.137 0.411 0.748 0.489 0.000 0.000 0.000 1.785 ESE 0.000 0.000 0.046 0.091 0.350 0.814 0.038 0.000 0.000 1.339 SE 0.000 0.000 0.594 0.594 0.748 0.610 0.188 0.000 0.000 2.734 SSE 0.000 0.046 0.320 0.640 0.663 0.731 0.225 0.000 0.000 2.624 S 0.000 0.046 0.640 0.731 0.397 0.447 0.076 0.000 0.000 2.337 SSW 0.000 0.000 0.411 0.822 0.442 0.727 0.188 0.000 0.000 2.590 SW 0.000 0.000 0.640 0.411 0.265 0.041 0.000 0.000 0.000 1.357 WSW 0.000 0.000 0.137 0.365 0.135 0.038 0.000 0.000 0.000 0.676 W 0.000 0.046 0.320 0.457 0.355 0.082 0.000 0.000 0.000 1.259 WNW 0.000 0.000 0.137 0.183 0.046 0.282 0.038 0.000 0.000 0.686 NW 0.000 0.046 0.000 0.046 0.217 0.079 0.000 0.000 0.000 0.388 NNW 0.000 0.000 0.183 0.091 0.180 0.320 0.000 0.000 0.000 0.773 SUBTOTAL 0.000 0.274 4.386 5.939 5.915 9.494 1.205 0.000 0.000 27.213 TOTAL HOURS OF VALID OBSERVATIONS 2189.000 TOTAL HOURS OF ELEVATED RELEASES 2054.930 TOTAL HOURS OF STABILITY CLASS E 630.000 TOTAL HOURS OF ELEVATED STABILITY CLASS E 595.690 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/10 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-119 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.046 0.395 0.401 0.000 0.000 0.000 0.842 NNE 0.000 0.046 0.000 0.183 0.261 0.997 0.038 0.000 0.000 1.524 NE 0.000 0.000 0.228 0.594 0.226 1.327 0.038 0.000 0.000 2.413 ENE 0.000 0.000 0.046 0.365 0.656 0.691 0.000 0.000 0.000 1.758 E 0.000 0.000 0.046 0.503 0.661 0.490 0.000 0.000 0.000 1.700 ESE 0.000 0.000 0.137 0.411 0.307 0.283 0.000 0.000 0.000 1.138 SE 0.000 0.000 0.274 0.183 0.177 0.042 0.000 0.000 0.000 0.676 SSE 0.000 0.000 0.091 0.274 0.045 0.042 0.000 0.000 0.000 0.453 S 0.000 0.000 0.274 0.137 0.000 0.039 0.000 0.000 0.000 0.450 SSW 0.000 0.000 0.137 0.091 0.177 0.204 0.000 0.000 0.000 0.609 SW 0.000 0.000 0.183 0.000 0.000 0.000 0.000 0.000 0.000 0.183 WSW 0.000 0.000 0.228 0.091 0.000 0.000 0.000 0.000 0.000 0.320 W 0.000 0.000 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.137 WNW 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 NW 0.000 0.000 0.046 0.046 0.000 0.081 0.000 0.000 0.000 0.172 NNW 0.000 0.000 0.046 0.091 0.043 0.160 0.000 0.000 0.000 0.340 SUBTOTAL 0.000 0.091 1.873 3.015 2.949 4.757 0.076 0.000 0.000 12.762 TOTAL HOURS OF VALID OBSERVATIONS 2189.000 TOTAL HOURS OF ELEVATED RELEASES 2054.930 TOTAL HOURS OF STABILITY CLASS F 295.640 TOTAL HOURS OF ELEVATED STABILITY CLASS F 279.350 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/10 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-120 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNE 0.000 0.000 0.046 0.000 0.087 0.235 0.038 0.000 0.000 0.405 NE 0.000 0.000 0.000 0.091 0.131 0.289 0.000 0.000 0.000 0.511 ENE 0.000 0.000 0.000 0.274 0.132 0.165 0.000 0.000 0.000 0.571 E 0.000 0.000 0.000 0.046 0.044 0.041 0.037 0.000 0.000 0.168 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.046 0.046 0.046 0.042 0.000 0.000 0.000 0.179 SSE 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 S 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.091 SSW 0.000 0.000 0.046 0.091 0.000 0.000 0.000 0.000 0.000 0.137 SW 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.091 WSW 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.091 W 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.091 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 NNW 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.091 SUBTOTAL 0.000 0.000 0.548 0.685 0.439 0.772 0.075 0.000 0.000 2.520 TOTAL HOURS OF VALID OBSERVATIONS 2189.000 TOTAL HOURS OF ELEVATED RELEASES 2054.930 TOTAL HOURS OF STABILITY CLASS G 59.200 TOTAL HOURS OF ELEVATED STABILITY CLASS G 55.170 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/10 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-121 BROWNS FERRY NUCLEAR PLANT 2016 METEOROLOGICAL DATA TABLE 8D JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL RELEASE MODE AND ELEVATED RELEASE MODE)

FOURTH QUARTER

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-122 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.107 0.013 0.000 0.000 0.120 NNE 0.000 0.000 0.000 0.000 0.000 0.074 0.000 0.000 0.000 0.074 NE 0.000 0.000 0.000 0.000 0.000 0.009 0.028 0.000 0.000 0.037 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.005 0.000 0.000 0.000 0.000 0.005 ESE 0.000 0.000 0.000 0.030 0.056 0.000 0.000 0.000 0.000 0.086 SE 0.000 0.000 0.016 0.157 0.024 0.000 0.000 0.000 0.000 0.197 SSE 0.000 0.000 0.078 0.152 0.000 0.000 0.000 0.000 0.000 0.230 S 0.000 0.000 0.029 0.039 0.000 0.000 0.000 0.000 0.000 0.069 SSW 0.000 0.000 0.000 0.065 0.021 0.000 0.000 0.000 0.000 0.086 SW 0.000 0.000 0.000 0.013 0.000 0.000 0.000 0.000 0.000 0.013 WSW 0.000 0.000 0.000 0.006 0.000 0.000 0.000 0.000 0.000 0.006 W 0.000 0.000 0.000 0.003 0.007 0.000 0.000 0.000 0.000 0.010 WNW 0.000 0.000 0.000 0.000 0.001 0.014 0.000 0.000 0.000 0.015 NW 0.000 0.000 0.000 0.000 0.005 0.060 0.044 0.000 0.000 0.108 NNW 0.000 0.000 0.000 0.000 0.004 0.060 0.044 0.000 0.000 0.108 SUBTOTAL 0.000 0.000 0.124 0.466 0.121 0.324 0.129 0.000 0.000 1.163 TOTAL HOURS OF VALID OBSERVATIONS 2204.000 TOTAL HOURS OF GROUND LEVEL RELEASE 247.070 TOTAL HOURS OF STABILITY CLASS A 45.030 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS A 25.640 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/27 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-123 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.050 NNE 0.000 0.000 0.000 0.000 0.006 0.036 0.000 0.000 0.000 0.043 NE 0.000 0.000 0.000 0.000 0.008 0.000 0.009 0.000 0.000 0.017 ENE 0.000 0.000 0.000 0.000 0.003 0.000 0.000 0.000 0.000 0.003 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.010 0.000 0.000 0.000 0.000 0.000 0.010 SE 0.000 0.000 0.000 0.011 0.000 0.000 0.000 0.000 0.000 0.011 SSE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 S 0.000 0.000 0.015 0.018 0.000 0.000 0.000 0.000 0.000 0.032 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.005 0.041 0.000 0.000 0.000 0.046 NW 0.000 0.000 0.000 0.000 0.008 0.044 0.029 0.079 0.000 0.161 NNW 0.000 0.000 0.000 0.000 0.004 0.042 0.009 0.000 0.000 0.055 SUBTOTAL 0.000 0.000 0.015 0.039 0.034 0.213 0.048 0.079 0.000 0.428 TOTAL HOURS OF VALID OBSERVATIONS 2204.000 TOTAL HOURS OF GROUND LEVEL RELEASE 247.070 TOTAL HOURS OF STABILITY CLASS B 43.910 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS B 9.440 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/27 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-124 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.028 0.014 0.000 0.000 0.000 0.041 NNE 0.000 0.000 0.000 0.000 0.015 0.030 0.000 0.000 0.000 0.045 NE 0.000 0.000 0.000 0.000 0.009 0.014 0.000 0.000 0.000 0.023 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.020 0.029 0.000 0.000 0.000 0.000 0.049 SE 0.000 0.000 0.001 0.015 0.000 0.000 0.000 0.000 0.000 0.016 SSE 0.000 0.000 0.016 0.000 0.000 0.000 0.000 0.000 0.000 0.016 S 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SSW 0.000 0.000 0.003 0.000 0.000 0.000 0.000 0.000 0.000 0.003 SW 0.000 0.000 0.000 0.002 0.000 0.000 0.000 0.000 0.000 0.002 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.000 0.000 0.009 WNW 0.000 0.000 0.000 0.000 0.011 0.031 0.017 0.000 0.000 0.060 NW 0.000 0.000 0.000 0.000 0.006 0.020 0.018 0.037 0.000 0.080 NNW 0.000 0.000 0.000 0.002 0.020 0.053 0.000 0.000 0.000 0.075 SUBTOTAL 0.000 0.000 0.020 0.040 0.118 0.171 0.035 0.037 0.000 0.421 TOTAL HOURS OF VALID OBSERVATIONS 2204.000 TOTAL HOURS OF GROUND LEVEL RELEASE 247.070 TOTAL HOURS OF STABILITY CLASS C 79.610 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS C 9.270 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/27 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-125 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.003 0.051 0.101 0.137 0.000 0.000 0.000 0.291 NNE 0.000 0.000 0.001 0.048 0.089 0.123 0.000 0.000 0.000 0.260 NE 0.000 0.000 0.000 0.029 0.054 0.020 0.000 0.000 0.000 0.103 ENE 0.000 0.000 0.000 0.019 0.015 0.000 0.000 0.000 0.000 0.034 E 0.000 0.000 0.005 0.024 0.015 0.000 0.000 0.000 0.000 0.043 ESE 0.000 0.000 0.029 0.130 0.074 0.000 0.000 0.000 0.000 0.233 SE 0.000 0.000 0.025 0.027 0.000 0.000 0.000 0.000 0.000 0.053 SSE 0.000 0.000 0.045 0.022 0.000 0.000 0.000 0.000 0.000 0.067 S 0.000 0.002 0.050 0.098 0.021 0.000 0.000 0.000 0.000 0.171 SSW 0.000 0.000 0.018 0.000 0.000 0.000 0.000 0.000 0.000 0.018 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.001 0.005 0.008 0.000 0.000 0.000 0.000 0.014 W 0.000 0.000 0.004 0.024 0.028 0.023 0.000 0.000 0.000 0.078 WNW 0.000 0.000 0.000 0.005 0.026 0.149 0.039 0.000 0.000 0.220 NW 0.000 0.000 0.000 0.014 0.056 0.205 0.375 0.038 0.000 0.688 NNW 0.000 0.000 0.000 0.019 0.109 0.235 0.035 0.000 0.000 0.397 SUBTOTAL 0.000 0.002 0.180 0.516 0.596 0.890 0.449 0.038 0.000 2.672 TOTAL HOURS OF VALID OBSERVATIONS 2204.000 TOTAL HOURS OF GROUND LEVEL RELEASE 247.070 TOTAL HOURS OF STABILITY CLASS D 743.400 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS D 58.880 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/27 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-126 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.042 0.056 0.015 0.044 0.000 0.000 0.000 0.157 NNE 0.000 0.007 0.010 0.078 0.067 0.016 0.000 0.000 0.000 0.178 NE 0.000 0.000 0.009 0.027 0.039 0.022 0.000 0.000 0.000 0.097 ENE 0.000 0.010 0.010 0.026 0.014 0.000 0.000 0.000 0.000 0.059 E 0.000 0.007 0.046 0.078 0.000 0.000 0.000 0.000 0.000 0.130 ESE 0.000 0.012 0.145 0.278 0.008 0.000 0.000 0.000 0.000 0.442 SE 0.000 0.000 0.112 0.049 0.000 0.000 0.000 0.000 0.000 0.160 SSE 0.000 0.000 0.087 0.135 0.045 0.000 0.000 0.000 0.000 0.267 S 0.000 0.007 0.145 0.117 0.331 0.221 0.000 0.000 0.000 0.821 SSW 0.000 0.000 0.035 0.025 0.049 0.000 0.000 0.000 0.000 0.110 SW 0.000 0.005 0.005 0.007 0.000 0.000 0.000 0.000 0.000 0.017 WSW 0.000 0.000 0.000 0.000 0.008 0.000 0.000 0.000 0.000 0.008 W 0.000 0.000 0.005 0.005 0.000 0.009 0.000 0.000 0.000 0.019 WNW 0.000 0.000 0.000 0.015 0.006 0.016 0.061 0.000 0.000 0.098 NW 0.000 0.000 0.002 0.028 0.019 0.069 0.000 0.039 0.000 0.157 NNW 0.000 0.000 0.034 0.120 0.061 0.091 0.000 0.000 0.000 0.305 SUBTOTAL 0.000 0.047 0.686 1.044 0.664 0.488 0.061 0.039 0.000 3.028 TOTAL HOURS OF VALID OBSERVATIONS 2204.000 TOTAL HOURS OF GROUND LEVEL RELEASE 247.070 TOTAL HOURS OF STABILITY CLASS E 675.530 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS E 66.740 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/27 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-127 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.006 0.132 0.090 0.017 0.000 0.000 0.000 0.000 0.245 NNE 0.000 0.000 0.028 0.167 0.024 0.000 0.000 0.000 0.000 0.218 NE 0.000 0.007 0.012 0.041 0.020 0.000 0.000 0.000 0.000 0.081 ENE 0.000 0.013 0.049 0.013 0.000 0.000 0.000 0.000 0.000 0.074 E 0.000 0.006 0.106 0.061 0.000 0.000 0.000 0.000 0.000 0.173 ESE 0.000 0.032 0.134 0.013 0.000 0.000 0.000 0.000 0.000 0.178 SE 0.000 0.031 0.029 0.035 0.000 0.000 0.000 0.000 0.000 0.095 SSE 0.000 0.051 0.031 0.043 0.045 0.000 0.000 0.000 0.000 0.171 S 0.000 0.010 0.153 0.239 0.311 0.271 0.000 0.000 0.000 0.984 SSW 0.000 0.005 0.018 0.015 0.000 0.000 0.000 0.000 0.000 0.038 SW 0.000 0.000 0.000 0.008 0.000 0.000 0.000 0.000 0.000 0.008 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.004 0.000 0.000 0.000 0.000 0.000 0.000 0.004 WNW 0.000 0.004 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 NW 0.000 0.000 0.002 0.006 0.000 0.000 0.000 0.000 0.000 0.008 NNW 0.000 0.000 0.060 0.080 0.008 0.000 0.000 0.000 0.000 0.148 SUBTOTAL 0.000 0.165 0.758 0.811 0.425 0.271 0.000 0.000 0.000 2.430 TOTAL HOURS OF VALID OBSERVATIONS 2204.000 TOTAL HOURS OF GROUND LEVEL RELEASE 247.070 TOTAL HOURS OF STABILITY CLASS F 429.840 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS F 53.550 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/27 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-128 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.014 0.066 0.091 0.000 0.000 0.000 0.000 0.000 0.170 NNE 0.000 0.007 0.020 0.013 0.000 0.000 0.000 0.000 0.000 0.040 NE 0.000 0.004 0.020 0.006 0.000 0.000 0.000 0.000 0.000 0.029 ENE 0.000 0.010 0.049 0.004 0.000 0.000 0.000 0.000 0.000 0.063 E 0.000 0.017 0.057 0.005 0.000 0.000 0.000 0.000 0.000 0.079 ESE 0.000 0.020 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.029 SE 0.000 0.049 0.021 0.009 0.000 0.000 0.000 0.000 0.000 0.079 SSE 0.000 0.064 0.143 0.000 0.000 0.000 0.000 0.000 0.000 0.207 S 0.000 0.013 0.130 0.000 0.174 0.000 0.000 0.000 0.000 0.317 SSW 0.000 0.001 0.011 0.000 0.000 0.000 0.000 0.000 0.000 0.013 SW 0.000 0.003 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.008 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.001 0.024 0.007 0.000 0.000 0.000 0.000 0.000 0.033 SUBTOTAL 0.000 0.206 0.555 0.134 0.174 0.000 0.000 0.000 0.000 1.069 TOTAL HOURS OF VALID OBSERVATIONS 2204.000 TOTAL HOURS OF GROUND LEVEL RELEASE 247.070 TOTAL HOURS OF STABILITY CLASS G 186.680 TOTAL HOURS OF GROUND LEVEL STABILITY CLASS G 23.550 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/27 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-129 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.183 0.032 0.000 0.215 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.074 0.000 0.000 0.074 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.038 0.000 0.000 0.000 0.038 SE 0.000 0.000 0.000 0.000 0.000 0.120 0.037 0.000 0.000 0.157 SSE 0.000 0.000 0.000 0.000 0.042 0.080 0.148 0.000 0.000 0.270 S 0.000 0.000 0.000 0.000 0.087 0.039 0.000 0.000 0.000 0.125 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.000 0.129 0.277 0.441 0.032 0.000 0.880 TOTAL HOURS OF VALID OBSERVATIONS 2204.000 TOTAL HOURS OF ELEVATED RELEASES 1956.930 TOTAL HOURS OF STABILITY CLASS A 45.030 TOTAL HOURS OF ELEVATED STABILITY CLASS A 19.390 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/27 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-130 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.116 0.110 0.000 0.000 0.226 NNE 0.000 0.000 0.000 0.000 0.000 0.154 0.075 0.000 0.000 0.229 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.072 0.000 0.000 0.072 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.111 0.000 0.000 0.111 SE 0.000 0.000 0.000 0.000 0.044 0.166 0.000 0.000 0.000 0.209 SSE 0.000 0.000 0.000 0.000 0.131 0.000 0.037 0.030 0.007 0.205 S 0.000 0.000 0.000 0.000 0.000 0.041 0.038 0.000 0.000 0.078 SSW 0.000 0.000 0.000 0.045 0.000 0.158 0.000 0.000 0.000 0.203 SW 0.000 0.000 0.000 0.045 0.000 0.039 0.000 0.000 0.000 0.085 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.145 0.000 0.000 0.145 SUBTOTAL 0.000 0.000 0.000 0.091 0.174 0.674 0.588 0.030 0.007 1.564 TOTAL HOURS OF VALID OBSERVATIONS 2204.000 TOTAL HOURS OF ELEVATED RELEASES 1956.930 TOTAL HOURS OF STABILITY CLASS B 43.910 TOTAL HOURS OF ELEVATED STABILITY CLASS B 34.470 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/27 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-131 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.237 0.149 0.029 0.000 0.415 NNE 0.000 0.000 0.000 0.000 0.043 0.199 0.074 0.000 0.000 0.316 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.036 0.000 0.000 0.036 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.117 0.000 0.000 0.000 0.117 SE 0.000 0.000 0.000 0.045 0.217 0.316 0.112 0.000 0.000 0.690 SSE 0.000 0.000 0.000 0.000 0.000 0.080 0.036 0.021 0.000 0.137 S 0.000 0.000 0.000 0.000 0.000 0.038 0.000 0.000 0.000 0.038 SSW 0.000 0.000 0.000 0.136 0.000 0.116 0.075 0.000 0.000 0.327 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.000 0.045 W 0.000 0.000 0.000 0.000 0.045 0.124 0.000 0.000 0.000 0.169 WNW 0.000 0.000 0.000 0.000 0.044 0.041 0.075 0.000 0.000 0.160 NW 0.000 0.000 0.000 0.000 0.000 0.238 0.223 0.000 0.007 0.468 NNW 0.000 0.000 0.000 0.000 0.000 0.196 0.075 0.000 0.000 0.272 SUBTOTAL 0.000 0.000 0.000 0.227 0.349 1.703 0.856 0.049 0.007 3.191 TOTAL HOURS OF VALID OBSERVATIONS 2204.000 TOTAL HOURS OF ELEVATED RELEASES 1956.930 TOTAL HOURS OF STABILITY CLASS C 79.610 TOTAL HOURS OF ELEVATED STABILITY CLASS C 70.340 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/27 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-132 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.045 0.227 0.441 1.475 1.292 0.029 0.000 3.509 NNE 0.000 0.000 0.136 0.136 0.656 1.241 0.483 0.000 0.000 2.652 NE 0.000 0.000 0.227 0.363 0.564 0.891 0.036 0.000 0.000 2.082 ENE 0.000 0.000 0.091 0.181 0.172 0.205 0.000 0.000 0.000 0.649 E 0.000 0.000 0.136 0.091 0.086 0.080 0.038 0.000 0.000 0.431 ESE 0.000 0.000 0.227 0.227 0.397 0.558 0.075 0.000 0.000 1.484 SE 0.000 0.000 0.454 1.044 0.657 0.885 0.480 0.218 0.000 3.736 SSE 0.000 0.000 0.590 0.499 0.221 0.436 0.368 0.117 0.000 2.231 S 0.000 0.000 0.408 0.136 0.045 0.351 0.480 0.067 0.000 1.488 SSW 0.000 0.000 0.272 0.227 0.044 0.234 0.149 0.049 0.000 0.975 SW 0.000 0.000 0.272 0.136 0.085 0.040 0.000 0.000 0.000 0.534 WSW 0.000 0.000 0.181 0.227 0.090 0.080 0.038 0.000 0.000 0.616 W 0.000 0.000 0.091 0.272 0.616 0.437 0.222 0.000 0.000 1.638 WNW 0.000 0.000 0.181 0.363 0.699 0.676 0.555 0.060 0.000 2.535 NW 0.000 0.000 0.091 0.227 0.350 1.556 0.956 0.296 0.026 3.501 NNW 0.000 0.000 0.000 0.272 0.605 1.200 0.921 0.000 0.000 2.998 SUBTOTAL 0.000 0.000 3.403 4.628 5.728 10.345 6.093 0.835 0.026 31.058 TOTAL HOURS OF VALID OBSERVATIONS 2204.000 TOTAL HOURS OF ELEVATED RELEASES 1956.930 TOTAL HOURS OF STABILITY CLASS D 743.400 TOTAL HOURS OF ELEVATED STABILITY CLASS D 684.520 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/27 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-133 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.091 0.136 0.305 0.592 0.481 0.000 0.000 1.604 NNE 0.000 0.000 0.091 0.181 0.475 1.032 0.336 0.000 0.000 2.115 NE 0.000 0.000 0.091 0.408 0.655 0.719 0.038 0.000 0.000 1.911 ENE 0.000 0.000 0.136 0.272 0.309 0.279 0.000 0.000 0.000 0.996 E 0.000 0.000 0.045 0.227 0.218 0.322 0.000 0.000 0.000 0.812 ESE 0.000 0.000 0.181 0.318 0.434 1.356 0.113 0.000 0.000 2.402 SE 0.000 0.000 0.272 0.635 0.524 1.902 0.559 0.090 0.000 3.982 SSE 0.000 0.045 0.136 0.635 0.388 0.873 0.479 0.279 0.010 2.846 S 0.000 0.000 0.091 0.318 0.178 0.948 0.848 0.460 0.030 2.873 SSW 0.000 0.000 0.045 0.363 0.352 0.675 0.407 0.204 0.000 2.045 SW 0.000 0.000 0.091 0.318 0.134 0.039 0.038 0.000 0.000 0.618 WSW 0.000 0.000 0.045 0.181 0.088 0.000 0.036 0.000 0.000 0.352 W 0.000 0.000 0.045 0.318 0.222 0.081 0.075 0.000 0.000 0.742 WNW 0.000 0.000 0.045 0.363 0.088 0.201 0.073 0.030 0.000 0.800 NW 0.000 0.091 0.181 0.227 0.086 0.407 0.222 0.036 0.000 1.250 NNW 0.000 0.045 0.045 0.136 0.387 1.547 0.113 0.000 0.000 2.273 SUBTOTAL 0.000 0.181 1.633 5.036 4.841 10.974 3.817 1.100 0.039 27.622 TOTAL HOURS OF VALID OBSERVATIONS 2204.000 TOTAL HOURS OF ELEVATED RELEASES 1956.930 TOTAL HOURS OF STABILITY CLASS E 675.530 TOTAL HOURS OF ELEVATED STABILITY CLASS E 608.790 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/27 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-134 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.045 0.045 0.130 0.679 0.149 0.000 0.000 1.049 NNE 0.000 0.000 0.000 0.000 0.175 1.140 0.113 0.000 0.000 1.427 NE 0.000 0.000 0.136 0.272 0.309 0.599 0.075 0.000 0.000 1.392 ENE 0.000 0.000 0.091 0.181 0.176 0.477 0.000 0.000 0.000 0.925 E 0.000 0.000 0.091 0.091 0.302 0.650 0.000 0.000 0.000 1.133 ESE 0.000 0.000 0.136 0.227 0.216 0.970 0.038 0.000 0.000 1.587 SE 0.000 0.000 0.272 0.363 0.433 1.295 0.180 0.062 0.000 2.606 SSE 0.000 0.000 0.136 0.454 0.265 0.626 0.329 0.092 0.002 1.904 S 0.000 0.000 0.227 0.136 0.259 0.718 0.370 0.035 0.018 1.763 SSW 0.000 0.000 0.000 0.091 0.304 0.202 0.075 0.000 0.000 0.672 SW 0.000 0.000 0.000 0.045 0.044 0.000 0.000 0.000 0.000 0.089 WSW 0.000 0.000 0.136 0.227 0.044 0.000 0.000 0.000 0.000 0.407 W 0.000 0.000 0.091 0.363 0.090 0.000 0.000 0.000 0.000 0.544 WNW 0.000 0.000 0.091 0.091 0.089 0.000 0.000 0.000 0.000 0.271 NW 0.000 0.000 0.000 0.091 0.266 0.079 0.000 0.000 0.000 0.436 NNW 0.000 0.045 0.045 0.181 0.000 0.594 0.000 0.000 0.000 0.867 SUBTOTAL 0.000 0.045 1.497 2.858 3.105 8.029 1.329 0.189 0.020 17.073 TOTAL HOURS OF VALID OBSERVATIONS 2204.000 TOTAL HOURS OF ELEVATED RELEASES 1956.930 TOTAL HOURS OF STABILITY CLASS F 429.840 TOTAL HOURS OF ELEVATED STABILITY CLASS F 376.290 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/27 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-135 SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.045 0.045 0.000 0.199 0.000 0.000 0.000 0.290 NNE 0.000 0.045 0.000 0.000 0.000 0.079 0.000 0.000 0.000 0.124 NE 0.000 0.000 0.000 0.045 0.086 0.437 0.000 0.000 0.000 0.569 ENE 0.000 0.045 0.000 0.136 0.176 0.206 0.000 0.000 0.000 0.563 E 0.000 0.000 0.000 0.045 0.042 0.042 0.000 0.000 0.000 0.130 ESE 0.000 0.000 0.045 0.045 0.000 0.040 0.000 0.000 0.000 0.131 SE 0.000 0.045 0.363 0.771 0.830 0.206 0.000 0.032 0.000 2.248 SSE 0.000 0.045 0.363 0.272 0.000 0.000 0.149 0.087 0.000 0.917 S 0.000 0.000 0.091 0.136 0.177 0.039 0.000 0.000 0.000 0.442 SSW 0.000 0.000 0.272 0.091 0.045 0.000 0.000 0.000 0.000 0.408 SW 0.000 0.045 0.318 0.091 0.000 0.000 0.000 0.000 0.000 0.454 WSW 0.000 0.000 0.136 0.000 0.000 0.000 0.000 0.000 0.000 0.136 W 0.000 0.000 0.045 0.091 0.045 0.000 0.000 0.000 0.000 0.181 WNW 0.000 0.000 0.091 0.136 0.134 0.000 0.000 0.000 0.000 0.361 NW 0.000 0.045 0.000 0.181 0.132 0.000 0.000 0.000 0.000 0.359 NNW 0.000 0.000 0.045 0.000 0.043 0.000 0.000 0.000 0.000 0.088 SUBTOTAL 0.000 0.272 1.815 2.087 1.711 1.248 0.149 0.119 0.000 7.402 TOTAL HOURS OF VALID OBSERVATIONS 2204.000 TOTAL HOURS OF ELEVATED RELEASES 1956.930 TOTAL HOURS OF STABILITY CLASS G 186.680 TOTAL HOURS OF ELEVATED STABILITY CLASS G 163.130 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S DATE PRINTED: 2017/01/27 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-136 BROWNS FERRY NUCLEAR PLANT 2016 METEOROLOGICAL DATA TABLE 9A JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES FIRST QUARTER

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-137 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 SSE 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 S 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 SSW 0.000 0.000 0.000 0.000 0.000 0.046 0.093 0.046 0.000 0.185 SW 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.046 0.000 0.139 0.139 0.046 0.000 0.370 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2160 TOTAL HOURS OF STABILITY CLASS A 8 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A 8 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2160 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2016/05/06 MEAN WIND SPEED = 13.11 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-138 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.046 0.093 0.000 0.000 0.139 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.046 0.139 0.000 0.000 0.000 0.185 SE 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.093 SSE 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 S 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.093 0.000 0.139 SW 0.000 0.000 0.000 0.046 0.093 0.046 0.046 0.000 0.000 0.231 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.046 0.093 0.000 0.000 0.139 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.046 0.278 0.324 0.278 0.093 0.000 1.019 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2160 TOTAL HOURS OF STABILITY CLASS B 22 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B 22 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2160 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2016/05/06 MEAN WIND SPEED = 10.89 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-139 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.185 0.139 0.000 0.000 0.324 NNE 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.093 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 ESE 0.000 0.000 0.000 0.000 0.046 0.185 0.000 0.000 0.000 0.231 SE 0.000 0.000 0.000 0.046 0.093 0.046 0.000 0.000 0.000 0.185 SSE 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.093 S 0.000 0.000 0.000 0.046 0.046 0.046 0.000 0.000 0.000 0.139 SSW 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.139 0.000 0.231 SW 0.000 0.000 0.000 0.046 0.000 0.000 0.046 0.000 0.000 0.093 WSW 0.000 0.000 0.046 0.000 0.000 0.093 0.000 0.000 0.000 0.139 W 0.000 0.000 0.000 0.000 0.046 0.046 0.046 0.046 0.000 0.185 WNW 0.000 0.000 0.000 0.000 0.000 0.185 0.324 0.370 0.000 0.880 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.185 0.000 0.000 0.185 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.093 0.000 0.185 SUBTOTAL 0.000 0.000 0.093 0.139 0.324 0.926 0.880 0.648 0.000 3.009 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2160 TOTAL HOURS OF STABILITY CLASS C 65 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 65 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2160 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2016/05/06 MEAN WIND SPEED = 13.30 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-140 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.093 0.231 0.463 1.065 1.065 0.000 0.000 2.917 NNE 0.000 0.000 0.093 0.185 0.185 1.250 0.787 0.093 0.000 2.593 NE 0.000 0.000 0.046 0.231 0.185 0.694 0.370 0.000 0.000 1.528 ENE 0.000 0.000 0.000 0.278 0.231 0.833 0.324 0.000 0.000 1.667 E 0.000 0.000 0.093 0.278 0.324 0.602 0.093 0.000 0.000 1.389 ESE 0.000 0.000 0.139 0.231 0.324 0.926 0.324 0.093 0.000 2.037 SE 0.000 0.000 0.139 0.278 0.185 0.185 0.602 0.648 0.000 2.037 SSE 0.000 0.046 0.000 0.093 0.139 0.231 0.463 0.185 0.000 1.157 S 0.000 0.000 0.185 0.185 0.046 0.231 0.556 0.463 0.093 1.759 SSW 0.000 0.000 0.185 0.139 0.046 0.370 0.324 0.556 0.000 1.620 SW 0.000 0.000 0.185 0.093 0.046 0.463 0.139 0.093 0.000 1.019 WSW 0.000 0.000 0.046 0.324 0.139 0.694 0.370 0.093 0.231 1.898 W 0.000 0.000 0.046 0.278 0.463 0.694 1.111 0.648 0.278 3.519 WNW 0.000 0.000 0.185 0.278 0.417 1.435 1.204 1.759 0.139 5.417 NW 0.000 0.000 0.046 0.139 0.324 0.926 2.407 1.667 0.093 5.602 NNW 0.000 0.000 0.000 0.046 0.278 1.667 1.898 0.602 0.509 5.000 SUBTOTAL 0.000 0.046 1.481 3.287 3.796 12.269 12.037 6.898 1.343 41.157 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2160 TOTAL HOURS OF STABILITY CLASS D 889 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D 889 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2160 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2016/05/06 MEAN WIND SPEED = 12.80 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-141 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.093 0.278 0.833 1.019 0.139 0.000 2.361 NNE 0.000 0.000 0.093 0.093 0.324 0.509 0.417 0.139 0.000 1.574 NE 0.000 0.000 0.000 0.093 0.185 0.741 0.370 0.093 0.000 1.481 ENE 0.000 0.000 0.000 0.046 0.139 0.602 0.324 0.046 0.046 1.204 E 0.000 0.000 0.000 0.046 0.185 0.370 0.278 0.000 0.000 0.880 ESE 0.000 0.000 0.000 0.139 0.185 0.602 0.694 0.185 0.139 1.944 SE 0.000 0.000 0.000 0.093 0.185 0.556 2.037 0.509 0.093 3.472 SSE 0.000 0.000 0.000 0.093 0.139 0.741 1.898 1.528 0.972 5.370 S 0.000 0.000 0.046 0.000 0.139 0.833 1.343 1.806 1.019 5.185 SSW 0.000 0.000 0.046 0.046 0.139 0.787 1.806 1.528 0.185 4.537 SW 0.000 0.000 0.046 0.093 0.324 1.157 0.694 0.139 0.000 2.454 WSW 0.000 0.000 0.046 0.000 0.093 1.065 0.463 0.046 0.000 1.713 W 0.000 0.046 0.185 0.139 0.185 0.278 0.278 0.185 0.000 1.296 WNW 0.000 0.046 0.046 0.185 0.093 0.324 0.185 0.000 0.000 0.880 NW 0.000 0.000 0.000 0.046 0.093 0.556 1.296 0.139 0.000 2.130 NNW 0.000 0.000 0.093 0.000 0.093 0.694 2.037 0.093 0.000 3.009 SUBTOTAL 0.000 0.093 0.602 1.204 2.778 10.648 15.139 6.574 2.454 39.491 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2160 TOTAL HOURS OF STABILITY CLASS E 853 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E 853 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2160 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2016/05/06 MEAN WIND SPEED = 14.35 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-142 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.046 0.139 0.000 0.093 0.231 0.093 0.000 0.602 NNE 0.000 0.000 0.046 0.139 0.046 0.185 0.602 0.046 0.000 1.065 NE 0.000 0.000 0.046 0.000 0.046 0.093 0.324 0.000 0.000 0.509 ENE 0.000 0.000 0.046 0.046 0.000 0.000 0.185 0.000 0.000 0.278 E 0.000 0.000 0.000 0.000 0.000 0.139 0.000 0.000 0.000 0.139 ESE 0.000 0.093 0.093 0.046 0.046 0.278 0.231 0.000 0.000 0.787 SE 0.000 0.000 0.231 0.046 0.000 0.093 0.231 0.185 0.046 0.833 SSE 0.000 0.093 0.139 0.093 0.000 0.278 1.389 1.157 0.694 3.843 S 0.000 0.000 0.093 0.000 0.139 0.185 1.667 0.648 0.093 2.824 SSW 0.000 0.000 0.000 0.046 0.000 0.139 0.417 0.046 0.000 0.648 SW 0.000 0.000 0.046 0.000 0.000 0.000 0.185 0.000 0.000 0.231 WSW 0.000 0.000 0.046 0.000 0.046 0.046 0.000 0.000 0.000 0.139 W 0.000 0.000 0.093 0.046 0.046 0.093 0.000 0.000 0.000 0.278 WNW 0.000 0.000 0.046 0.000 0.046 0.231 0.000 0.000 0.000 0.324 NW 0.000 0.000 0.139 0.093 0.093 0.278 0.093 0.000 0.000 0.694 NNW 0.000 0.000 0.000 0.046 0.000 0.093 0.046 0.046 0.000 0.231 SUBTOTAL 0.000 0.185 1.111 0.741 0.509 2.222 5.602 2.222 0.833 13.426 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2160 TOTAL HOURS OF STABILITY CLASS F 290 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F 290 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2160 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2016/05/06 MEAN WIND SPEED = 14.08 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-143 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT JAN 1, 2016 - MAR 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.093 NE 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 ENE 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 E 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 SSE 0.000 0.000 0.000 0.046 0.000 0.093 0.231 0.185 0.000 0.556 S 0.000 0.000 0.046 0.046 0.000 0.046 0.185 0.046 0.000 0.370 SSW 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 SW 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.093 WSW 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 SUBTOTAL 0.000 0.046 0.093 0.278 0.046 0.278 0.509 0.278 0.000 1.528 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2160 TOTAL HOURS OF STABILITY CLASS G 33 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G 33 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2160 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2016/05/06 MEAN WIND SPEED = 12.25 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-144 BROWNS FERRY NUCLEAR PLANT 2016 METEOROLOGICAL DATA TABLE 9B JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES SECOND QUARTER

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-145 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SE 0.000 0.000 0.000 0.000 0.000 0.230 0.138 0.000 0.000 0.367 SSE 0.000 0.000 0.000 0.046 0.046 0.046 0.138 0.092 0.046 0.413 S 0.000 0.000 0.000 0.000 0.000 0.321 0.046 0.000 0.000 0.367 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.000 0.000 0.092 SW 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 WSW 0.000 0.000 0.000 0.000 0.046 0.138 0.138 0.000 0.000 0.321 W 0.000 0.000 0.000 0.000 0.000 0.138 0.046 0.000 0.000 0.184 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.046 0.092 0.918 0.597 0.138 0.046 1.837 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2178 TOTAL HOURS OF STABILITY CLASS A 40 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A 40 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2178 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2016/08/05 MEAN WIND SPEED = 12.25 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-146 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.092 0.092 0.000 0.000 0.184 NNE 0.000 0.000 0.000 0.000 0.000 0.138 0.046 0.000 0.000 0.184 NE 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.275 0.000 0.000 0.275 SE 0.000 0.000 0.000 0.000 0.046 0.046 0.275 0.138 0.000 0.505 SSE 0.000 0.000 0.000 0.092 0.046 0.000 0.138 0.046 0.000 0.321 S 0.000 0.000 0.000 0.138 0.046 0.184 0.367 0.092 0.000 0.826 SSW 0.000 0.000 0.000 0.230 0.092 0.413 0.138 0.000 0.000 0.872 SW 0.000 0.000 0.000 0.184 0.092 0.138 0.046 0.000 0.000 0.459 WSW 0.000 0.000 0.000 0.046 0.138 0.184 0.046 0.000 0.000 0.413 W 0.000 0.000 0.000 0.000 0.046 0.138 0.321 0.046 0.000 0.551 WNW 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.092 0.000 0.184 NW 0.000 0.000 0.000 0.000 0.000 0.046 0.138 0.046 0.092 0.321 NNW 0.000 0.000 0.000 0.000 0.000 0.138 0.046 0.000 0.000 0.184 SUBTOTAL 0.000 0.000 0.000 0.689 0.505 1.607 1.974 0.459 0.092 5.326 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2178 TOTAL HOURS OF STABILITY CLASS B 116 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B 116 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2178 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2016/08/05 MEAN WIND SPEED = 11.98 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-147 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.459 0.597 0.000 0.000 1.056 NNE 0.000 0.000 0.000 0.000 0.000 0.643 0.138 0.000 0.000 0.781 NE 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.092 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.230 0.138 0.046 0.000 0.413 SE 0.000 0.000 0.000 0.184 0.230 0.230 0.092 0.138 0.000 0.872 SSE 0.000 0.000 0.046 0.046 0.000 0.092 0.000 0.000 0.000 0.184 S 0.000 0.000 0.000 0.275 0.046 0.184 0.184 0.092 0.046 0.826 SSW 0.000 0.000 0.000 0.275 0.092 0.184 0.138 0.000 0.000 0.689 SW 0.000 0.000 0.046 0.275 0.092 0.275 0.092 0.000 0.000 0.781 WSW 0.000 0.000 0.046 0.092 0.230 0.184 0.138 0.000 0.000 0.689 W 0.000 0.000 0.000 0.046 0.184 0.184 0.275 0.046 0.000 0.735 WNW 0.000 0.000 0.000 0.000 0.046 0.138 0.459 0.413 0.000 1.056 NW 0.000 0.000 0.000 0.000 0.000 0.321 0.275 0.184 0.000 0.781 NNW 0.000 0.000 0.000 0.000 0.000 0.138 0.184 0.138 0.000 0.459 SUBTOTAL 0.000 0.000 0.138 1.194 0.964 3.306 2.709 1.056 0.046 9.412 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2178 TOTAL HOURS OF STABILITY CLASS C 205 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 205 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2178 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2016/08/05 MEAN WIND SPEED = 11.44 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-148 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.046 0.275 0.275 1.194 0.689 0.092 0.000 2.571 NNE 0.000 0.046 0.000 0.046 0.321 0.918 0.413 0.000 0.000 1.745 NE 0.000 0.000 0.046 0.092 0.505 0.597 0.046 0.000 0.000 1.286 ENE 0.000 0.000 0.092 0.092 0.046 0.092 0.000 0.000 0.000 0.321 E 0.000 0.000 0.092 0.092 0.092 0.138 0.184 0.000 0.000 0.597 ESE 0.000 0.000 0.138 0.551 0.551 0.643 0.551 0.413 0.000 2.847 SE 0.000 0.000 0.367 0.459 0.321 0.597 0.597 1.056 0.138 3.535 SSE 0.000 0.000 0.184 0.321 0.321 0.735 0.459 0.275 0.138 2.433 S 0.000 0.000 0.321 0.367 0.321 0.964 1.561 0.597 0.138 4.270 SSW 0.000 0.000 0.138 0.275 0.689 1.102 1.010 0.184 0.000 3.398 SW 0.000 0.000 0.184 0.321 0.367 0.964 0.184 0.000 0.000 2.020 WSW 0.000 0.000 0.092 0.275 0.505 1.056 0.184 0.046 0.046 2.204 W 0.000 0.046 0.000 0.275 0.597 1.469 0.735 0.184 0.000 3.306 WNW 0.000 0.000 0.000 0.138 0.413 1.745 1.056 0.275 0.000 3.627 NW 0.000 0.000 0.000 0.092 0.184 1.194 1.194 0.184 0.000 2.847 NNW 0.000 0.000 0.092 0.000 0.092 1.240 0.551 0.092 0.000 2.066 SUBTOTAL 0.000 0.092 1.791 3.673 5.601 14.646 9.412 3.398 0.459 39.073 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2178 TOTAL HOURS OF STABILITY CLASS D 851 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D 851 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2178 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2016/08/05 MEAN WIND SPEED = 10.93 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-149 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.092 0.184 0.643 1.010 0.184 0.000 2.112 NNE 0.000 0.046 0.000 0.092 0.138 0.551 0.735 0.138 0.000 1.699 NE 0.000 0.046 0.000 0.092 0.092 0.459 0.413 0.092 0.000 1.194 ENE 0.000 0.000 0.046 0.138 0.092 0.230 0.046 0.092 0.000 0.643 E 0.000 0.000 0.046 0.046 0.184 0.275 0.046 0.000 0.000 0.597 ESE 0.000 0.000 0.092 0.275 0.230 0.826 1.194 0.000 0.000 2.617 SE 0.000 0.000 0.046 0.046 0.413 0.964 0.781 0.184 0.000 2.433 SSE 0.000 0.092 0.138 0.230 0.367 0.964 0.735 0.184 0.046 2.755 S 0.000 0.000 0.275 0.230 0.413 1.056 1.837 0.230 0.184 4.224 SSW 0.000 0.046 0.046 0.046 0.321 0.964 0.964 0.092 0.000 2.479 SW 0.000 0.000 0.138 0.000 0.138 1.102 0.321 0.046 0.000 1.745 WSW 0.000 0.000 0.000 0.046 0.367 0.735 0.184 0.000 0.000 1.331 W 0.000 0.000 0.092 0.275 0.505 1.102 0.230 0.046 0.000 2.250 WNW 0.000 0.000 0.046 0.092 0.184 0.459 0.230 0.000 0.000 1.010 NW 0.000 0.046 0.000 0.046 0.138 0.321 0.413 0.000 0.000 0.964 NNW 0.000 0.000 0.046 0.092 0.092 0.367 1.331 0.046 0.000 1.974 SUBTOTAL 0.000 0.275 1.010 1.837 3.857 11.019 10.468 1.331 0.230 30.028 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2178 TOTAL HOURS OF STABILITY CLASS E 654 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E 654 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2178 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2016/08/05 MEAN WIND SPEED = 11.35 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-150 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.184 1.286 0.184 0.000 1.653 NNE 0.000 0.000 0.092 0.046 0.092 0.275 0.551 0.092 0.000 1.148 NE 0.000 0.000 0.000 0.046 0.092 0.046 0.275 0.138 0.000 0.597 ENE 0.000 0.000 0.046 0.092 0.046 0.459 0.138 0.092 0.000 0.872 E 0.000 0.000 0.000 0.092 0.092 0.138 0.184 0.000 0.000 0.505 ESE 0.000 0.000 0.046 0.275 0.184 0.138 0.138 0.000 0.000 0.781 SE 0.000 0.000 0.000 0.138 0.046 0.367 0.092 0.000 0.000 0.643 SSE 0.000 0.000 0.092 0.092 0.275 0.138 0.046 0.046 0.000 0.689 S 0.000 0.000 0.000 0.000 0.000 0.367 0.413 0.046 0.000 0.826 SSW 0.000 0.000 0.046 0.046 0.000 0.046 0.459 0.000 0.000 0.597 SW 0.000 0.000 0.000 0.000 0.000 0.092 0.092 0.000 0.000 0.184 WSW 0.000 0.000 0.184 0.184 0.000 0.000 0.000 0.000 0.000 0.367 W 0.000 0.000 0.046 0.000 0.230 0.046 0.000 0.000 0.000 0.321 WNW 0.000 0.000 0.000 0.092 0.230 0.092 0.000 0.000 0.000 0.413 NW 0.000 0.046 0.046 0.092 0.092 0.230 0.046 0.000 0.000 0.551 NNW 0.000 0.000 0.046 0.000 0.000 0.138 0.459 0.000 0.000 0.643 SUBTOTAL 0.000 0.046 0.643 1.194 1.377 2.755 4.178 0.597 0.000 10.790 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2178 TOTAL HOURS OF STABILITY CLASS F 235 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F 235 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2178 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2016/08/05 MEAN WIND SPEED = 10.97 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-151 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT APR 1, 2016 - JUN 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.000 0.000 0.092 NNE 0.000 0.000 0.000 0.046 0.000 0.184 0.367 0.046 0.000 0.643 NE 0.000 0.000 0.000 0.000 0.000 0.092 0.000 0.046 0.000 0.138 ENE 0.000 0.000 0.000 0.000 0.000 0.367 0.184 0.000 0.000 0.551 E 0.000 0.000 0.000 0.000 0.000 0.138 0.000 0.000 0.000 0.138 ESE 0.000 0.000 0.046 0.184 0.046 0.046 0.000 0.000 0.000 0.321 SE 0.000 0.000 0.092 0.092 0.046 0.046 0.138 0.000 0.000 0.413 SSE 0.000 0.000 0.092 0.184 0.000 0.184 0.000 0.000 0.000 0.459 S 0.000 0.000 0.046 0.092 0.046 0.092 0.046 0.000 0.000 0.321 SSW 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 SW 0.000 0.000 0.092 0.092 0.000 0.000 0.000 0.000 0.000 0.184 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 WNW 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 NW 0.000 0.000 0.046 0.000 0.046 0.046 0.000 0.000 0.000 0.138 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.459 0.781 0.184 1.194 0.826 0.092 0.000 3.535 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2178 TOTAL HOURS OF STABILITY CLASS G 77 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G 77 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2178 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2016/08/05 MEAN WIND SPEED = 9.17 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-152 BROWNS FERRY NUCLEAR PLANT 2016 METEOROLOGICAL DATA TABLE 9C JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES THIRD QUARTER

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-153 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.091 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.091 SE 0.000 0.000 0.000 0.000 0.228 0.137 0.091 0.000 0.000 0.457 SSE 0.000 0.000 0.000 0.183 0.091 0.183 0.183 0.046 0.000 0.685 S 0.000 0.000 0.000 0.000 0.046 0.183 0.137 0.000 0.000 0.365 SSW 0.000 0.000 0.000 0.000 0.000 0.183 0.000 0.000 0.000 0.183 SW 0.000 0.000 0.000 0.000 0.000 0.091 0.046 0.137 0.000 0.274 WSW 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.091 W 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.091 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.183 0.365 0.959 0.640 0.183 0.000 2.330 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2189 TOTAL HOURS OF STABILITY CLASS A 51 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A 51 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2189 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2017/01/10 MEAN WIND SPEED = 10.93 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-154 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.411 0.365 0.000 0.000 0.777 NNE 0.000 0.000 0.000 0.000 0.000 0.137 0.000 0.000 0.000 0.137 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 SE 0.000 0.000 0.000 0.137 0.274 0.137 0.183 0.000 0.000 0.731 SSE 0.000 0.000 0.000 0.503 0.091 0.137 0.000 0.000 0.000 0.731 S 0.000 0.000 0.000 0.091 0.046 0.046 0.137 0.000 0.000 0.320 SSW 0.000 0.000 0.000 0.183 0.046 0.091 0.000 0.000 0.000 0.320 SW 0.000 0.000 0.000 0.000 0.000 0.137 0.137 0.000 0.000 0.274 WSW 0.000 0.000 0.000 0.000 0.046 0.320 0.228 0.000 0.000 0.594 W 0.000 0.000 0.000 0.000 0.000 0.183 0.000 0.000 0.000 0.183 WNW 0.000 0.000 0.000 0.000 0.046 0.137 0.046 0.000 0.000 0.228 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.914 0.548 1.782 1.142 0.000 0.000 4.386 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2189 TOTAL HOURS OF STABILITY CLASS B 96 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B 96 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2189 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2017/01/10 MEAN WIND SPEED = 9.90 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-155 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.046 0.548 0.228 0.000 0.000 0.822 NNE 0.000 0.000 0.000 0.046 0.046 0.228 0.000 0.000 0.000 0.320 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.000 0.000 0.137 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.000 0.000 0.137 SE 0.000 0.000 0.046 0.228 0.228 0.091 0.183 0.000 0.000 0.777 SSE 0.000 0.000 0.046 0.274 0.183 0.137 0.000 0.137 0.000 0.777 S 0.000 0.000 0.183 0.183 0.137 0.228 0.365 0.000 0.000 1.096 SSW 0.000 0.000 0.091 0.183 0.091 0.137 0.000 0.000 0.000 0.503 SW 0.000 0.000 0.046 0.320 0.046 0.137 0.183 0.000 0.000 0.731 WSW 0.000 0.000 0.000 0.365 0.228 0.365 0.411 0.000 0.000 1.370 W 0.000 0.000 0.000 0.046 0.137 0.868 0.000 0.000 0.000 1.051 WNW 0.000 0.000 0.000 0.000 0.091 0.320 0.183 0.000 0.000 0.594 NW 0.000 0.000 0.000 0.000 0.000 0.320 0.091 0.000 0.000 0.411 NNW 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.091 SUBTOTAL 0.000 0.000 0.457 1.645 1.279 3.426 1.919 0.137 0.000 8.862 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2189 TOTAL HOURS OF STABILITY CLASS C 194 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 194 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2189 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2017/01/10 MEAN WIND SPEED = 9.11 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-156 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.046 0.137 0.228 0.868 0.685 0.046 0.000 2.010 NNE 0.000 0.000 0.137 0.091 0.274 0.731 0.365 0.000 0.000 1.599 NE 0.000 0.000 0.137 0.046 0.503 0.320 0.137 0.000 0.000 1.142 ENE 0.000 0.000 0.000 0.137 0.183 0.000 0.000 0.000 0.000 0.320 E 0.000 0.000 0.091 0.091 0.091 0.183 0.091 0.000 0.000 0.548 ESE 0.000 0.000 0.228 0.274 0.320 1.051 0.548 0.000 0.000 2.421 SE 0.000 0.000 0.137 0.685 0.548 0.548 0.594 0.274 0.000 2.787 SSE 0.000 0.000 0.548 0.640 0.365 0.640 1.416 0.594 0.000 4.203 S 0.000 0.000 0.914 0.914 0.731 2.056 0.685 0.183 0.000 5.482 SSW 0.000 0.046 0.411 0.777 0.731 1.736 0.868 0.046 0.000 4.614 SW 0.000 0.000 0.777 0.959 0.685 1.553 0.731 0.046 0.000 4.751 WSW 0.000 0.000 0.411 0.685 0.274 1.233 0.365 0.046 0.000 3.015 W 0.000 0.000 0.274 0.548 0.548 0.959 0.320 0.000 0.000 2.650 WNW 0.000 0.000 0.091 0.274 0.457 0.822 0.137 0.000 0.000 1.782 NW 0.000 0.000 0.091 0.228 0.183 0.411 0.091 0.046 0.000 1.051 NNW 0.000 0.000 0.046 0.137 0.091 0.320 0.365 0.000 0.000 0.959 SUBTOTAL 0.000 0.046 4.340 6.624 6.213 13.431 7.401 1.279 0.000 39.333 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2189 TOTAL HOURS OF STABILITY CLASS D 861 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D 861 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2189 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2017/01/10 MEAN WIND SPEED = 8.80 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-157 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.002 0.000 0.137 0.137 0.000 0.777 1.096 0.046 0.000 2.195 NNE 0.001 0.000 0.046 0.228 0.183 0.868 1.462 0.137 0.000 2.925 NE 0.002 0.000 0.137 0.137 0.320 0.777 1.051 0.183 0.000 2.606 ENE 0.002 0.000 0.091 0.091 0.365 0.548 0.320 0.000 0.000 1.418 E 0.001 0.000 0.046 0.137 0.320 0.640 0.183 0.000 0.000 1.326 ESE 0.002 0.000 0.137 0.000 0.046 0.731 0.457 0.000 0.000 1.373 SE 0.000 0.000 0.000 0.137 0.320 1.462 0.503 0.000 0.000 2.421 SSE 0.003 0.000 0.183 0.457 0.640 1.508 0.320 0.183 0.000 3.292 S 0.005 0.000 0.274 0.457 0.594 0.411 0.320 0.000 0.000 2.061 SSW 0.008 0.000 0.457 0.274 0.274 0.868 0.868 0.000 0.000 2.749 SW 0.006 0.000 0.365 0.411 0.320 0.548 0.411 0.000 0.000 2.062 WSW 0.004 0.046 0.183 0.228 0.183 0.274 0.046 0.000 0.000 0.963 W 0.006 0.046 0.320 0.411 0.274 0.503 0.183 0.000 0.000 1.742 WNW 0.001 0.000 0.046 0.183 0.137 0.411 0.091 0.000 0.000 0.869 NW 0.001 0.046 0.000 0.046 0.091 0.091 0.046 0.000 0.000 0.321 NNW 0.001 0.000 0.046 0.091 0.046 0.091 0.320 0.000 0.000 0.595 SUBTOTAL 0.046 0.137 2.467 3.426 4.111 10.507 7.675 0.548 0.000 28.917 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2189 TOTAL HOURS OF STABILITY CLASS E 633 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E 633 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2189 TOTAL HOURS CALM 1 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2017/01/10 MEAN WIND SPEED = 9.64 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-158 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.091 0.183 0.274 0.000 0.000 0.548 NNE 0.000 0.000 0.000 0.137 0.137 0.183 0.731 0.137 0.000 1.325 NE 0.000 0.000 0.091 0.137 0.091 0.274 1.051 0.274 0.000 1.919 ENE 0.000 0.000 0.046 0.091 0.137 0.777 0.731 0.000 0.000 1.782 E 0.000 0.000 0.000 0.046 0.228 0.822 0.183 0.000 0.000 1.279 ESE 0.000 0.000 0.091 0.228 0.091 0.959 0.274 0.000 0.000 1.645 SE 0.000 0.000 0.046 0.320 0.137 0.503 0.046 0.000 0.000 1.051 SSE 0.000 0.000 0.137 0.228 0.274 0.274 0.091 0.000 0.000 1.005 S 0.000 0.000 0.091 0.183 0.046 0.091 0.000 0.000 0.000 0.411 SSW 0.000 0.000 0.046 0.091 0.137 0.091 0.228 0.046 0.000 0.640 SW 0.000 0.000 0.091 0.137 0.000 0.091 0.046 0.000 0.000 0.365 WSW 0.000 0.000 0.000 0.091 0.000 0.046 0.000 0.000 0.000 0.137 W 0.000 0.046 0.183 0.091 0.046 0.000 0.000 0.000 0.000 0.365 WNW 0.000 0.000 0.046 0.091 0.046 0.000 0.000 0.000 0.000 0.183 NW 0.000 0.046 0.091 0.137 0.000 0.183 0.000 0.000 0.000 0.457 NNW 0.000 0.000 0.091 0.046 0.137 0.091 0.046 0.000 0.000 0.411 SUBTOTAL 0.000 0.091 1.051 2.056 1.599 4.568 3.700 0.457 0.000 13.522 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2189 TOTAL HOURS OF STABILITY CLASS F 296 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F 296 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2189 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2017/01/10 MEAN WIND SPEED = 9.81 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-159 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT JUL 1, 2016 - SEP 30, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.091 NNE 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.228 0.000 0.320 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.183 0.000 0.000 0.183 ENE 0.000 0.000 0.000 0.000 0.000 0.320 0.091 0.000 0.000 0.411 E 0.000 0.000 0.091 0.137 0.000 0.183 0.000 0.000 0.000 0.411 ESE 0.000 0.000 0.000 0.137 0.046 0.137 0.046 0.000 0.000 0.365 SE 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.091 SSE 0.000 0.000 0.046 0.000 0.000 0.091 0.000 0.000 0.000 0.137 S 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 SSW 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.091 SW 0.000 0.000 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.137 WSW 0.000 0.000 0.000 0.137 0.000 0.000 0.000 0.000 0.000 0.137 W 0.000 0.000 0.000 0.046 0.046 0.046 0.000 0.000 0.000 0.137 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.091 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.503 0.594 0.091 0.868 0.365 0.228 0.000 2.650 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2189 TOTAL HOURS OF STABILITY CLASS G 58 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G 58 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2189 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2017/01/10 MEAN WIND SPEED = 8.83 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-160 BROWNS FERRY NUCLEAR PLANT 2016 METEOROLOGICAL DATA TABLE 9D JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES FOURTH QUARTER

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-161 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.136 0.136 0.000 0.272 NNE 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.091 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.045 0.045 0.000 0.000 0.091 SE 0.000 0.000 0.000 0.000 0.000 0.091 0.091 0.000 0.000 0.181 SSE 0.000 0.000 0.000 0.000 0.000 0.136 0.136 0.045 0.000 0.318 S 0.000 0.000 0.000 0.000 0.045 0.000 0.045 0.000 0.000 0.091 SSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 SUBTOTAL 0.000 0.000 0.000 0.000 0.045 0.272 0.544 0.181 0.000 1.044 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2204 TOTAL HOURS OF STABILITY CLASS A 23 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A 23 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2204 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2017/01/27 MEAN WIND SPEED = 14.63 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-162 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9< DELTA T<=-1.7 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.045 0.227 0.000 0.000 0.272 NNE 0.000 0.000 0.000 0.000 0.000 0.045 0.227 0.000 0.000 0.272 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.091 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.045 0.000 0.091 SE 0.000 0.000 0.000 0.000 0.045 0.181 0.045 0.000 0.000 0.272 SSE 0.000 0.000 0.000 0.000 0.136 0.000 0.045 0.045 0.045 0.272 S 0.000 0.000 0.000 0.000 0.000 0.045 0.045 0.000 0.000 0.091 SSW 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.045 SW 0.000 0.000 0.000 0.045 0.045 0.000 0.181 0.000 0.000 0.272 WSW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 W 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.091 0.000 0.181 SUBTOTAL 0.000 0.000 0.000 0.045 0.227 0.363 0.907 0.272 0.045 1.860 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2204 TOTAL HOURS OF STABILITY CLASS B 41 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B 41 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2204 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2017/01/27 MEAN WIND SPEED = 14.19 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-163 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7< DELTA T<=-1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.227 0.272 0.045 0.000 0.544 NNE 0.000 0.000 0.000 0.000 0.000 0.272 0.091 0.000 0.000 0.363 NE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.045 ENE 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 E 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 ESE 0.000 0.000 0.000 0.000 0.091 0.136 0.091 0.000 0.000 0.318 SE 0.000 0.000 0.045 0.000 0.045 0.136 0.272 0.045 0.000 0.544 SSE 0.000 0.000 0.000 0.000 0.000 0.091 0.045 0.091 0.000 0.227 S 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.045 SSW 0.000 0.000 0.000 0.045 0.000 0.000 0.136 0.045 0.000 0.227 SW 0.000 0.000 0.000 0.091 0.000 0.000 0.045 0.000 0.000 0.136 WSW 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.000 0.045 W 0.000 0.000 0.000 0.000 0.091 0.181 0.091 0.000 0.000 0.363 WNW 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.091 NW 0.000 0.000 0.000 0.000 0.000 0.181 0.272 0.000 0.045 0.499 NNW 0.000 0.000 0.000 0.000 0.000 0.181 0.091 0.000 0.000 0.272 SUBTOTAL 0.000 0.000 0.045 0.136 0.227 1.543 1.452 0.272 0.045 3.721 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2204 TOTAL HOURS OF STABILITY CLASS C 82 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C 82 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2204 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2017/01/27 MEAN WIND SPEED = 12.60 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-164 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5< DELTA T<=-0.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.318 0.318 1.270 1.588 0.635 0.000 4.129 NNE 0.000 0.000 0.181 0.091 0.272 1.270 0.998 0.045 0.000 2.858 NE 0.000 0.000 0.091 0.363 0.363 1.361 0.045 0.045 0.000 2.269 ENE 0.000 0.000 0.045 0.227 0.045 0.318 0.045 0.000 0.000 0.681 E 0.000 0.045 0.136 0.136 0.091 0.181 0.136 0.045 0.000 0.771 ESE 0.000 0.000 0.181 0.318 0.408 0.635 0.499 0.000 0.000 2.042 SE 0.000 0.000 0.363 0.590 0.318 0.862 0.499 0.544 0.000 3.176 SSE 0.000 0.000 0.454 0.091 0.635 0.454 0.590 0.318 0.045 2.586 S 0.000 0.091 0.318 0.045 0.091 0.091 0.681 0.091 0.000 1.407 SSW 0.000 0.000 0.272 0.045 0.045 0.091 0.499 0.045 0.091 1.089 SW 0.000 0.000 0.181 0.045 0.181 0.045 0.000 0.000 0.000 0.454 WSW 0.000 0.000 0.181 0.272 0.227 0.227 0.091 0.000 0.000 0.998 W 0.000 0.000 0.136 0.181 0.318 0.771 0.363 0.181 0.045 1.996 WNW 0.000 0.000 0.181 0.272 0.726 0.953 0.681 0.181 0.091 3.085 NW 0.000 0.000 0.045 0.181 0.227 1.134 0.998 0.817 0.363 3.766 NNW 0.000 0.000 0.000 0.091 0.408 1.497 1.134 0.363 0.000 3.494 SUBTOTAL 0.000 0.136 2.768 3.267 4.673 11.162 8.848 3.312 0.635 34.800 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2204 TOTAL HOURS OF STABILITY CLASS D 767 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D 767 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2204 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2017/01/27 MEAN WIND SPEED = 11.05 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-165 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5< DELTA T<= 1.5 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.045 0.091 0.544 0.953 0.318 0.000 1.951 NNE 0.000 0.000 0.000 0.091 0.045 1.134 0.998 0.227 0.000 2.495 NE 0.000 0.000 0.000 0.136 0.091 0.817 0.771 0.136 0.000 1.951 ENE 0.000 0.000 0.000 0.045 0.181 0.635 0.272 0.000 0.000 1.134 E 0.000 0.000 0.091 0.091 0.136 0.318 0.272 0.000 0.000 0.907 ESE 0.000 0.000 0.045 0.045 0.227 0.363 0.590 0.091 0.000 1.361 SE 0.000 0.000 0.136 0.136 0.408 0.998 2.178 0.454 0.000 4.310 SSE 0.000 0.000 0.091 0.136 0.363 1.270 0.998 0.635 0.454 3.947 S 0.000 0.000 0.000 0.181 0.499 0.907 0.998 0.998 0.771 4.356 SSW 0.000 0.000 0.091 0.091 0.181 0.862 1.089 0.408 0.272 2.995 SW 0.000 0.045 0.045 0.136 0.136 0.227 0.181 0.000 0.000 0.771 WSW 0.000 0.000 0.091 0.136 0.091 0.136 0.000 0.045 0.045 0.544 W 0.000 0.000 0.045 0.136 0.318 0.136 0.136 0.045 0.000 0.817 WNW 0.000 0.045 0.091 0.000 0.318 0.590 0.136 0.091 0.045 1.316 NW 0.000 0.000 0.136 0.045 0.136 0.272 0.181 0.227 0.000 0.998 NNW 0.000 0.000 0.181 0.000 0.045 0.771 1.044 0.091 0.000 2.132 SUBTOTAL 0.000 0.091 1.044 1.452 3.267 9.982 10.799 3.766 1.588 31.987 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2204 TOTAL HOURS OF STABILITY CLASS E 705 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E 705 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2204 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2017/01/27 MEAN WIND SPEED = 13.19 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-166 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F ( 1.5< DELTA T<= 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.091 0.091 0.817 0.136 0.000 1.134 NNE 0.000 0.000 0.000 0.045 0.000 0.136 0.998 0.136 0.000 1.316 NE 0.000 0.045 0.045 0.045 0.045 0.590 0.907 0.363 0.000 2.042 ENE 0.000 0.045 0.045 0.000 0.091 0.363 0.408 0.000 0.000 0.953 E 0.000 0.000 0.045 0.045 0.045 0.363 0.181 0.000 0.000 0.681 ESE 0.000 0.000 0.045 0.000 0.045 0.771 0.408 0.000 0.000 1.270 SE 0.000 0.000 0.091 0.181 0.091 0.907 0.681 0.272 0.000 2.223 SSE 0.000 0.000 0.181 0.136 0.227 0.862 0.998 0.454 0.045 2.904 S 0.000 0.045 0.000 0.091 0.272 0.862 0.817 0.136 0.227 2.450 SSW 0.000 0.000 0.000 0.091 0.227 0.454 0.635 0.045 0.000 1.452 SW 0.000 0.000 0.000 0.091 0.000 0.181 0.045 0.000 0.000 0.318 WSW 0.000 0.000 0.000 0.045 0.045 0.227 0.045 0.000 0.000 0.363 W 0.000 0.000 0.000 0.181 0.000 0.045 0.000 0.000 0.000 0.227 WNW 0.000 0.000 0.000 0.091 0.272 0.272 0.000 0.000 0.000 0.635 NW 0.000 0.000 0.000 0.045 0.136 0.091 0.045 0.000 0.000 0.318 NNW 0.000 0.000 0.000 0.000 0.091 0.272 0.181 0.045 0.000 0.590 SUBTOTAL 0.000 0.136 0.454 1.089 1.679 6.488 7.169 1.588 0.272 18.875 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2204 TOTAL HOURS OF STABILITY CLASS F 416 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F 416 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2204 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2017/01/27 MEAN WIND SPEED = 12.20 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-167 JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)

BROWNS FERRY NUCLEAR PLANT OCT 1, 2016 - DEC 31, 2016 WIND WIND SPEED(MPH)

DIRECTION CALM 0.60-1.40 1.41-3.40 3.41-5.40 5.41-7.40 7.41-12.40 12.41-18.40 18.41-24.40 >=24.41 TOTAL N 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.000 0.045 NNE 0.000 0.000 0.000 0.000 0.000 0.181 0.045 0.000 0.000 0.227 NE 0.000 0.045 0.000 0.000 0.000 0.045 0.272 0.000 0.000 0.363 ENE 0.000 0.000 0.000 0.000 0.045 0.091 0.227 0.000 0.000 0.363 E 0.000 0.091 0.136 0.045 0.045 0.363 0.045 0.000 0.000 0.726 ESE 0.000 0.000 0.000 0.091 0.136 0.091 0.000 0.000 0.000 0.318 SE 0.000 0.045 0.136 0.227 0.227 0.000 0.045 0.045 0.000 0.726 SSE 0.000 0.000 0.136 0.091 0.272 0.272 0.227 0.136 0.045 1.180 S 0.000 0.000 0.136 0.000 0.091 0.363 0.045 0.000 0.000 0.635 SSW 0.000 0.045 0.091 0.045 0.045 0.272 0.045 0.000 0.000 0.544 SW 0.000 0.000 0.045 0.136 0.181 0.136 0.045 0.000 0.000 0.544 WSW 0.000 0.045 0.045 0.318 0.045 0.000 0.000 0.000 0.000 0.454 W 0.000 0.000 0.045 0.091 0.181 0.045 0.000 0.000 0.000 0.363 WNW 0.000 0.091 0.181 0.045 0.045 0.181 0.000 0.000 0.000 0.544 NW 0.000 0.000 0.091 0.091 0.227 0.091 0.000 0.000 0.000 0.499 NNW 0.000 0.000 0.000 0.091 0.045 0.045 0.000 0.000 0.000 0.181 SUBTOTAL 0.000 0.363 1.044 1.270 1.588 2.178 1.044 0.181 0.045 7.713 TOTAL HOURS OF VALID STABILITY OBSERVATIONS 2204 TOTAL HOURS OF STABILITY CLASS G 170 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G 170 TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS 2204 TOTAL HOURS CALM 0 METEOROLOGICAL FACILITY: BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2017/01/27 MEAN WIND SPEED = 7.82 NOTE: TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT ATTACHMENT 1 E-168 Deviations from ODCM Controls and Surveillance Requirements This report is to comply with Browns Ferry Nuclear Plant Offsite Dose Calculation Manual (ODCM). The ODCM requires that all deviations be reported in the Annual Radioactive Effluent Release Report.

During the reporting period, January 1, 2016 through December 31, 2016, there were no deviations to the ODCM.

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT E-169 2016 Inoperable Radiological Effluent Instrumentation Report This report is to comply with Browns Ferry Nuclear Plant Offsite Dose Calculation Manual (ODCM) Sections 1/2.1.1 and 1/2.1.2. The ODCM requires the exertion of best efforts to return inoperable instruments to operable status within 30 days. Failure to return such instruments to an operable status within the prescribed interval requires a description in the Annual Radioactive Effluent Release Report.

During the reporting period, January 1, 2016 through December 31, 2016,there were five radiological instruments inoperable for greater than 30 days.

The 0-RM-90-130 radioactive liquid effluent monitor was inoperable from July 23, 2015 to April 1, 2016.This was due to Background radiation counts for BFN-0-RM-090-0130 being elevated (~2800 counts/sec) while in process preventing BFN-0-RM-090-0130 from being placed in service. It appeared that the elevated background was from an actual fixed background from within the containment chamber section of the process. WO 117211266 was initiated to disassemble the piping to perform cleaning of the containment chamber. Following the cleaning, minimal to no change in background counts were noted thus the work order is to replace the containment chamber and required associated flanged piping. Additional cleaning was performed (flushes) and a new monitor was also installed and calibrated (CR 110179)

The 0-RM-90-147/148 was declared inoperable on 2/10/2016 due to Stack Gas Rad Monitor CH1 and CH2 indicating low counts (9 counts and 10 counts respectfully). Operations entered LCOT# 0-090-ODCM-2016-0008. Monitor was declared operable on 4/20/2016. (CR 1135716)

The 0-FIC-77-60 Radwaste Discharge Valve Flow Loop was inoperable on 3/24/2016 during performance of 0-SI-4.8.A.1-1, Liquid Effluent Permit, due to the average flow rate being outside the plus or minus 8% of flow rate calculated based on tank volume change over time,(ODCM Table 2.1-1.d Channel Functional Test). LCOT# 0-077-ODCM-2016-0016. Monitor declared operable on 8/10/2016 during performance of 0-SI-4.8.A.1-1. (CRs 1153528, 1207403)

The 2-FCV-77-61 Radwaste Discharge Valve Flow Loop was declared inoperable on 7/14/2016 under LCOT# 2-077-ODCM-2016-0020. 2-SI-4.8.A.3, Automatic Isolation Logic Functional Test of Radwaste Discharge Valve, was not performed as scheduled because U-2 was on cooling towers. (CR 1190109)

On 11/14/2016, only partial performance with Attachment 3 of 2-SI-4.8.A.3 to be performed at a later date. (WO 118410520).

On 12/29/16,determination made that work could not be completed as scheduled due to on-going Radwaste upgrades. Performance of Attachment 3 and any other necessary sections of 2-SI-4.8.A.3 will be scheduled following completion of Radwaste upgrades. (WO 118315571)

The 3-FCV-77-61 Radwaste Discharge Valve inoperable under 3-77-ODCM-2013-22.

3-FCV-77-61 declared inoperable on 6/18/2013 due to failed A/C steps during the performance of 3-SI-4.8.A.3,Automatic Isolation Logic Functional Test of Radwaste Discharge Canal Valve 3-FCV-77-61. (CR 945823 and WO 116248474)

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT Groundwater Protection Program E-170 In 2007, the Nuclear Energy Institute (NEI) established the Groundwater Protection Initiative (GPI), NEI 07-07. The Groundwater Protection Initiative was established to 1) improve management of situations involving inadvertent radiological releases that get into groundwater and 2) to improve communication with external stakeholders to enhance trust and confidence on the part of local communities, States, the NRC, and the public in the nuclear industrys commitment to a high standard of public radiation safety and protection of the environment.

This section provides information and sample results from on-site groundwater locations that were sampled in support of the Groundwater Protection Initiative at Browns Ferry Nuclear Plant (BFN). The groundwater wells described in this section are not part of the Radiological Environmental Monitoring Program (REMP).

Onsite groundwater monitoring was performed in 2016. The purpose of on-site groundwater monitoring is to ensure timely detection of inadvertent radiological releases to groundwater.

Non REMP groundwater wells monitor for potential leaks from plant equipment. As part of the GPI, BFN monitored a total of 26 groundwater wells located in the Protected Area (PA) and the Owner Controlled Area (OCA) during 2016, with normal sampling frequencies quarterly and semiannually. Some wells were sampled monthly as certain criteria were met or for investigation purposes. Samples are routinely analyzed for environmental levels of tritium (H-3) and principle gamma emitters (PGE) with selected wells analyzed for Hard-to-Detect (HTD) radionuclides (Gross Alpha, Fe-55, Ni-63, Sr-89, and Sr-90). In support of the groundwater program the site also monitors onsite storm drains, catch basins and surface water.

In the early 2000s, BFN initiated a groundwater study to identify the source low levels of detected tritium onsite. Results from the groundwater study, completed in June 2006, suggest the source of tritiated groundwater were from historical leaks and spills associated with Radwaste/Condensate transfer tunnel. Groundwater and surface water level measurement during the study indicated the return channel and subsequently the Tennessee River will ultimately be recipient to tritiated groundwater discharge from the site. It has been determined that there are no groundwater wells onsite or within 2-miles of the site that are used as a source of drinking water. Groundwater movement in the area has been determined to be from the plant site toward the Tennessee River.

One event occurred in 2016 which required voluntary notification per NEI 07-07, Industry Groundwater Protection Initiative (Condition Report 1183798). The notification was prompted when two onsite groundwater wells, MW-01 and MW-08, exceeded the Environmental Protection Agency (EPA) drinking water value of 20,000 pCi/L (picocuries per liter) tritium (Condition Reports 1164659, 1183737). During the investigation of MW-01 exceeding the EPA limit, a leak within the Unit 2 Turbine Building Steam tunnel was found to be the apparent source. Following investigation, it was found that the leak from the Steam tunnel reached groundwater through degraded expansion joints within the tunnel room. BFN made an entry into the tunnel at full power to remove blockage from a floor drain which was allowing contaminated water to pool on the floor and reach the degraded expansion joints. The highest concentration well identified for year 2016 was MW-01 which resulted in 36,444 pCi/L of tritium.

The leak occurred underneath the turbine building in which followed a preferential flow path to the East and West sides of the plant. MW-01 is located on the West side of the plant and MW 08 is located on the East side of the plant. Since the initial spike of 36,444 pCi/L tritium in March 2016 for MW-01 and MW-08 tritium concentration of 22,400 pCi/L, the tritium concentration values have trended back down considerably. The site monitored MW-01, MW 08 and other groundwater wells down gradient of the leak on an increased frequency following the discovery of the leak. The leak within the U2 Turbine Building Steam Tunnel was

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT Groundwater Protection Program E-171 repaired in Spring 2017 during the Unit 2 Refueling Outage. The expansion joints, floor drains, and floor coatings were inspected during the Spring 2017 outage. The expansion joints in the tunnel were repaired by applying a coating atop the joint to keep future water from exiting the joints.

Groundwater sample results that were taken in support of the GPI for 2016 are listed in the tables below. Low levels of tritium were detected in the monitoring wells listed below. No other nuclides, other than tritium, were detected in any groundwater well, surface water, catch basin, or storm drain in 2016.

Sample Date Well ID Tritium Activity (pCi/L)

Gamma Activity (pCi/L)

Hard-to-Detect Activity (pCi/L) 1st Quarter 1/13/2016 13:54 GW Dewat A 1560

<MDA n/a 1/13/2016 14:15 GW Dewat E 7580

<MDA n/a 2/10/2016 10:45 GW Dewat A 7839

<MDA n/a 2/10/2016 11:00 GW Dewat E 12665

<MDA n/a 3/4/2016 11:45 GW Dewat A 5890

<MDA

<MDA 3/4/2016 12:20 GW Dewat E 13300

<MDA

<MDA 3/15/2016 12:25 GW MW-11

< 228

<MDA n/a 3/15/2016 12:55 GW MW-03 749

<MDA n/a 3/15/2016 14:35 GW MW-04 1963

<MDA n/a 3/15/2016 14:40 GW MW-10

< 228

<MDA n/a 3/15/2016 16:35 GW MW-09

< 228

<MDA n/a 3/15/2016 16:50 GW MW-02 1023

<MDA n/a 3/15/2016 18:35 GW MW-07 1032

<MDA n/a 3/16/2016 9:15 GW MW-08 2193

<MDA n/a 3/16/2016 11:00 GW MW-01 36444

<MDA n/a 3/17/2016 18:45 GW Dewat A 16146

<MDA n/a 1/13/2016 13:54 GW Dewat A 1560

<MDA n/a 1/13/2016 14:15 GW Dewat E 7580

<MDA n/a 2/10/2016 10:45 GW Dewat A 7839

<MDA n/a 2/10/2016 11:00 GW Dewat E 12665

<MDA n/a 3/4/2016 11:45 GW Dewat A 5890

<MDA n/a 3/4/2016 12:20 GW Dewat E 13300

<MDA n/a 3/15/2016 12:25 GW MW-11

< 228

<MDA n/a 3/15/2016 12:55 GW MW-03 749

<MDA n/a 3/15/2016 14:35 GW MW-04 1963

<MDA n/a 3/15/2016 14:40 GW MW-10

< 228

<MDA n/a 3/15/2016 16:35 GW MW-09

< 228

<MDA n/a 3/15/2016 16:50 GW MW-02 1023

<MDA n/a 3/15/2016 18:35 GW MW-07 1032

<MDA n/a 3/16/2016 9:15 GW MW-08 2193

<MDA n/a 3/16/2016 11:00 GW MW-01 36444

<MDA n/a 3/17/2016 18:45 GW Dewat A 16146

<MDA n/a 2nd Quarter 4/13/2016 13:00 GW Dewat A 787

<MDA n/a

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT Groundwater Protection Program E-172 Sample Date Well ID Tritium Activity (pCi/L)

Gamma Activity (pCi/L)

Hard-to-Detect Activity (pCi/L) 4/13/2016 13:30 GW Dewat E 11269

<MDA n/a 4/26/2016 11:55 GW MW-01 5660

<MDA n/a 4/26/2016 15:30 GW MW-01 5490

<MDA

<MDA 4/27/2016 15:15 GW MW-02 3895

<MDA

<MDA 4/28/2016 14:05 GW MW-04 3460

<MDA

<MDA 4/28/2016 15:00 GW Dewat A 15290

<MDA

<MDA 5/5/2016 15:00 GW MW-01 4245

<MDA n/a 5/12/2016 12:00 GW MW-01 3640

<MDA n/a 5/12/2016 12:45 GW Dewat A 15598

<MDA n/a 5/12/2016 13:15 GW Dewat E 11575

<MDA n/a 5/19/2016 14:45 GW MW-01 3550

<MDA n/a 5/26/2016 9:30 GW MW-04 1876

<MDA n/a 5/26/2016 11:00 GW MW-02 2232

<MDA n/a 5/27/2016 15:00 GW MW-01 3120

<MDA n/a 6/2/2016 9:00 GW Dewat E 11458

<MDA n/a 6/15/2016 8:15 GW MW-03 561

<MDA n/a 6/15/2016 9:15 GW MW-04 1909

<MDA n/a 6/15/2016 10:25 GW MW-02 1949

<MDA n/a 6/15/2016 11:25 GW MW-07 1052

<MDA n/a 6/15/2016 13:00 GW MW-08 22400

<MDA n/a 6/15/2016 14:35 GW MW-01 2760

<MDA n/a 6/15/2016 16:30 GW MW-09

< 224

<MDA n/a 6/16/2016 9:45 GW MW-10

< 202

<MDA n/a 6/16/2016 12:30 GW MW-11

< 202

<MDA n/a 6/16/2016 15:35 GW Dewat A 16200

<MDA n/a 6/16/2016 17:40 GW MW-08 21400

<MDA n/a 6/22/2016 10:00 GW MW-08 20900

<MDA

<MDA 6/29/2016 10:00 GW MW-08 17500

<MDA n/a 3rd Quarter 7/5/2016 10:20 GW MW-08 20700

<MDA n/a 7/6/2016 11:00 GW MW-07 981

<MDA n/a 7/6/2016 12:00 GW MW-02 557

<MDA n/a 7/6/2016 12:30 GW MW-01 1256

<MDA n/a 7/6/2016 13:20 GW MW-04 996

<MDA n/a 7/6/2016 14:05 GW Dewat E 10523

<MDA n/a 7/6/2016 14:10 GW Dewat A 2781

<MDA n/a 7/12/2016 14:00 GW MW-07

< 1820

<MDA n/a 7/12/2016 15:30 GW MW-08 16300

<MDA n/a 7/21/2016 9:05 GW MW-07

< 1900

<MDA n/a 7/21/2016 9:45 GW MW-08 11300

<MDA n/a 7/27/2016 21:00 GW MW-08 8060

<MDA n/a 7/27/2016 21:30 GW MW-07

< 1870

<MDA n/a 8/5/2016 9:45 GW MW-08 5270

<MDA n/a 8/5/2016 10:15 GW Dewat E 11400

<MDA n/a

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT Groundwater Protection Program E-173 Sample Date Well ID Tritium Activity (pCi/L)

Gamma Activity (pCi/L)

Hard-to-Detect Activity (pCi/L) 8/8/2016 15:15 GW MW-08 3340

<MDA n/a 8/17/2016 20:50 GW MW-08 3290

<MDA n/a 8/17/2016 21:10 GW Dewat A

< 1870

<MDA n/a 8/18/2016 14:00 GW Dewat E

< 1920

<MDA n/a 8/21/2016 13:30 GW Dewat E

< 1860

<MDA n/a 8/22/2016 19:10 GW MW-02 467

<MDA n/a 8/23/2016 5:40 GW MW-03 831

<MDA n/a 8/23/2016 6:30 GW MW-07 1008

<MDA n/a 8/23/2016 7:30 GW MW-04 396

<MDA n/a 8/23/2016 8:30 GW MW-01 840

<MDA n/a 8/23/2016 9:40 GW MW-08 4252

<MDA n/a 8/23/2016 11:30 GW MW-11 338

<MDA n/a 8/23/2016 13:20 GW MW-10 295

<MDA n/a 8/23/2016 14:55 GW MW-09 266

<MDA n/a 8/23/2016 17:00 GW Dewat A 1881

<MDA n/a 8/30/2016 11:20 GW MW-08 5140

<MDA n/a 9/12/2016 10:40 GW MW-08 4867

<MDA n/a 9/12/2016 11:30 GW MW-04 325

<MDA n/a 9/12/2016 13:10 GW Dewat A 1911

<MDA n/a 9/12/2016 13:25 GW Dewat E 902

<MDA n/a 4th Quarter 10/12/2016 10:30 GW MW-08 5160

<MDA n/a 10/12/2016 11:10 GW Dewat A 4820

<MDA n/a 10/12/2016 11:30 GW Dewat E 1680

<MDA n/a 10/12/2016 12:20 GW MW-01 2240

<MDA n/a 11/10/2016 11:40 GW MW-03 606

<MDA n/a 11/10/2016 12:50 GW MW-04 681

<MDA n/a 11/10/2016 14:15 GW MW-07 794

<MDA n/a 11/10/2016 15:25 GW MW-08 4667

<MDA n/a 11/11/2016 12:00 GW MW-11

< 217

<MDA n/a 11/11/2016 13:40 GW MW-10

< 217

<MDA n/a 11/11/2016 15:10 GW MW-09

< 217

<MDA n/a 11/11/2016 17:00 GW Dewat A 3413

<MDA n/a 12/7/2016 10:12 GW MW-08 1057

<MDA n/a 12/7/2016 10:40 GW Dewat E 3460

<MDA n/a 12/7/2016 11:00 GW Dewat A 8630

<MDA n/a 12/7/2016 13:00 GW MW-02 1122

<MDA n/a 12/7/2016 13:30 GW MW-01 2440

<MDA n/a

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT Groundwater Protection Program E-174 Catch Basin, Storm Drains, and Surface Water Quarterly Sampling Sample Date Location Tritium Activity (pCi/L)

Gamma Activity (pCi/L)

Hard-to-Detect Activity (pCi/L) 1st Quarter 1/13/2016 12:42 GW DSN015

< 240

<MDA n/a 1/13/2016 11:30 GW Sewage 287

<MDA n/a 1/13/2016 11:40 GW Sed Pond A

< 240

<MDA n/a 1/13/2016 12:15 GW DSN015D

< 240

<MDA n/a 1/13/2016 12:22 GW U3 EECW

< 240

<MDA n/a 1/13/2016 12:27 GW U2 EECW 637

<MDA n/a 1/13/2016 12:33 GW U1 EECW

< 240

<MDA n/a 1/28/2016 9:50 GW Sed Pond B 400

<MDA n/a 1/13/2016 12:42 GW DSN015

< 240

<MDA n/a 2nd Quarter 5/13/2016 10:40 GW U1 EECW

< 209

<MDA n/a 5/13/2016 11:00 GW DSN015

< 209

<MDA

<MDA 5/13/2016 11:20 GW U3 EECW

< 209

<MDA n/a 5/13/2016 13:00 GW DSN015D

< 209

<MDA n/a 5/13/2016 13:15 GW U2 EECW

< 209

<MDA n/a 5/25/2016 8:40 GW Sed Pond B

< 218

<MDA n/a 5/25/2016 8:45 GW Sed Pond A

< 218

<MDA n/a 5/25/2016 8:55 GW Sewage

< 218

<MDA n/a 6/17/2016 10:00 GW DSN015

< 1760

<MDA n/a 6/17/2016 10:05 GW DSN015D

< 1760

<MDA n/a 3rd Quarter 9/14/2016 9:40 GW Sed Pond A 345

<MDA n/a 9/14/2016 9:45 GW Sed Pond B 354

<MDA n/a 9/14/2016 9:50 GW Sewage

< 208

<MDA n/a 9/14/2016 10:50 GW DSN015D 381

<MDA n/a 9/14/2016 10:55 GW U3 EECW 293

<MDA n/a 9/14/2016 11:00 GW U2 EECW 217

<MDA n/a 9/14/2016 13:55 GW DSN015 381

<MDA n/a 9/14/2016 14:05 GW U1 EECW 443

<MDA n/a 4th Quarter 10/21/2016 13:30 GW U1 EECW

< 1120

<MDA n/a 10/21/2016 13:35 GW DSN015

< 1120

<MDA n/a 10/21/2016 13:40 GW U2 EECW

< 1120

<MDA n/a 10/21/2016 13:45 GW U3 EECW

< 1120

<MDA n/a 10/21/2016 13:50 GW DSN015D

< 1120

<MDA n/a 12/1/2016 8:50 GW Sed Pond B

< 1040

<MDA n/a 12/1/2016 9:00 GW Sed Pond A

< 1040

<MDA n/a 12/1/2016 9:10 GW Sewage

< 1040

<MDA n/a

BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 2016 Annual Radioactive EFFLUENT Release REPORT Groundwater Protection Program E-175

< MDA - less than minimum detectable activity Tritium LLD typically 270 pCi/L n/a - not analyzed 20,000 pCi/L tritium - Environmental Protection Agencys (EPA) standard for tritium associated with drinking water 1,000,000 pCi/L tritium - 10CFR20, Appendix B, Table 2, Column 2, Effluent Concentration limit