Tennessee Valley Authority, 1101 Market Street, Chattanooga, Tennessee 37402 April 30, 2012 10 CFR 50.4 10 CFR 50.36a ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Browns Ferry Nuclear Plant, Unit 1, 2, and 3 Facility Operating License Nos. DPR-33, DPR-52, and DPR-68 NRC Docket Nos. 50-259, 50-260, and 50-296
Subject:
Annual Radioactive Effluent Release Report - 2011 In accordance with the Browns Ferry Nuclear Plant (BFN), Units 1, 2, and 3, Technical Specification Section 5.6.3, the Tennessee Valley Authority (TVA) is submitting documents that collectively comprise the BFN Annual Radioactive Effluent Release Report for the period January through December 2011. This documentation is in conformance with 10 CFR 50.36a and 10 CFR Part 50, Appendix I Section IV.B.1. Also, in accordance with the BFN Offsite Dose Calculation Manual (ODCM) Section 1.1.1, Action (b), and Section 1.1.2, Action (c), TVA is providing the BFN Inoperable Radiological Effluent Instrumentation Report. provides the Radiological Impact Assessment Report. Enclosure 2 provides the Meteorological Data Tables. Enclosure 3 is the Effluent and Waste Disposal Annual Report, and Enclosure 4 is the Inoperable Radiological Effluent Instrumentation Report. Enclosure 5 provides the ODCM, Revision 21.
Printed on recycled paper
U.S. Nuclear Regulatory Commission Page 2 April 30, 2012 There are no regulatory commitments contained within this letter. If you have any questions concerning this submittal, please contact Tom Hess, at (423) 751-3487.
Respec ly, W. S w
ea a:n yr, Corporate Nuclear Licensing
Enclosures:
- 1. 2011 Radiological Impact Assessment
- 2. 2011 Meteorological Data Tables
- 3. 2011 Effluent and Waste Disposal Annual Report
- 4. 2011 Inoperable Radiological Effluent Instrumentation Report
- 5. Offsite Dose Calculation Manual, Revision 21 cc: (w/Enclosure):
NRC Regional Administrator - Region II NRC Senior Resident Inspector - Browns Ferry Nuclear Plant Browns Ferry Nuclear Plant Units 1, 2, and 3 2011 Radiological Impact Assessment Report (See Attached)
E1-1
V 2011 Radiological Impact Assessment Report I. INTRODUCTION Potential doses to the "maximum exposed individual" and the population around Browns Ferry Nuclear Plant (BFN) are calculated for each quarter as required in Section 5.2 of the Offsite Dose Calculation Manual (ODCM). The methodology used to estimate dose for determining plant releases for the reporting period is specified in Sections 6 and 7 of the ODCM. Dispersion of radioactive effluents in the environment is estimated using meteorological data and river flow measured during the period. In this report, the doses resulting from releases are described and compared to limits established for BFN.
II. DOSE LIMITS The ODCM specifies limits for the release of radioactive effluents, as well as limits for doses to the general public from the release of radioactive effluents. These limits are set well below the Technical Specification limits which govern the concentrations of radioactivity and doses permissible in unrestricted areas. This ensures that radioactive effluent releases are As Low As Reasonably Achievable.
The air dose limits in areas at and beyond the Site Boundary due to noble gases released in gaseous effluents per unit are:
< 5 mrad per quarter and
< 10 mrad per year for gamma radiation.
- and -
< 10 mrad per quarter and
< 20 mrad per year for beta radiation.
The dose limits to a member of the public in an unrestricted area from radioiodines, radioactive materials in particulate form, and radionuclides other than noble gases with half-lives > 8 days released in gaseous effluents for each unit are:
< 7.5 mrem per quarter and
< 15 mrem per year to any organ.
The dose or dose commitment to a member of the public from radioactive material in liquid effluents released to unrestricted areas are:
< 1.5 mrem per quarter and
< 3 mrem per year to the total body,
- and -
< 5 mrem per quarter and
< 10 mrem per year to any organ.
The limit for the total effective dose equivalent to an individual member of the public inside the site boundary is:
100 mrem per year.
E1-2
2011 Radiological Impact Assessment Report The Environmental Protection Agency limits for total dose to any member of the public in the vicinity of a nuclear power plant, established in the Environmental Dose Standard of 40 CFR 190, are:
< 25 mrem per year to the whole body,
< 75 mrem per year to the thyroid,
- and -
< 25 mrem per year to any other organ.
III. DOSE CALCULATIONS Estimated doses to members of the public are determined using computer models (the Gaseous Effluent Licensing Code, and the Quarterly Water Dose Assessment Code (QWATA)). These models are based on guidance provided by the Nuclear Regulatory Commission (NRC) for determining the potential dose to individuals and populations living in the vicinity of the plant. The area around the plant is analyzed to determine the pathways through which the public may receive a dose. The doses calculated are a representation of the dose to a "maximum exposed individual." Some of the factors used in these calculations (such as ingestion rates) are maximum values to ensure conservative reporting data. The values chosen will tend to overestimate the dose. The expected dose to actual individuals is lower. The calculated doses are presented in Tables 1, 2, 3, 4, 5, 6, and 7.
IV. DOSES FROM AIRBORNE EFFLUENTS For airborne effluents, members of the public can be exposed to radiation from several sources: direct radiation from the radioactivity in the air, direct radiation from radioactivity deposited on the ground, inhalation of airborne radioactivity, ingestion of vegetation which contains radioactivity deposited from the atmosphere, and ingestion of milk and beef which contains radioactivity deposited from the atmosphere onto vegetation and subsequently consumed by animals.
Airborne Release Points There are four monitored release points from BFN: the turbine building, the radwaste building, the reactor building, and the stack.
Releases from the turbine building are considered ground-level releases. The ground-level Joint Frequency Distribution (JFD) is derived from wind speeds and directions measured 10.5 meters above the ground and from the vertical temperature difference between 10.03 and 45.30 meters, and are presented for each quarter in, 2011 Meteorological Data Tables, Tables 1, 2, 3, and 4.
Releases from the radwaste and reactor buildings are considered split-level releases.
Portions of the release are treated as ground-level while other portions are considered elevated depending on the ratio of the vertical exit velocity to the horizontal wind speed.
The split-level dispersion approach is implemented using a model that requires two complete quarterly JFDs for each effluent vent, one for the ground-level releases and one for the elevated releases. The ground-level portion of the split-level JFD is based on wind E1-3
2011 Radiological Impact Assessment Report speeds and directions measured 10.5 meters above ground-level and from the vertical temperature difference between 10.03 and 45.30 meters. The elevated portion of the split-level JFD is based on wind speeds and direction measurements at the 45.74 meter level and the vertical temperature difference between 10.03 and 89.59 meters. Both of these JFDs are given for each quarter in Enclosure 2, 2011 Meteorological Data Tables, Tables 5, 6, 7, and 8.
Releases from the stack are considered to be elevated releases. The JFDs for elevated releases are based on wind directions and wind speeds measured at 90.29 meters and the vertical temperature difference between 10.03 and 89.59 meters, and are given for each quarter in Enclosure 2,2011 Meteorological Data Tables, Tables 9, 10, 11, and 12.
Meteorological Data Meteorological variables at BFN are measured continuously. Measurements collected include wind speed and wind direction at heights of 10.5, 45.74, and 90.29 meters above the ground, and temperature at heights of 10.03, 45.30, and 89.59 meters above the ground. Quarterly JFDs are calculated for each release point using the appropriate levels of meteorological data. A quarterly JFD gives the percentage of the time that the wind is blowing out of a particular upwind compass sector in a particular range of wind speeds for a given stability class A through G. The wind speeds are divided into nine wind speed ranges. Calms are distributed by direction in proportion to the distribution of noncalm wind directions less than 1.6 m/s (3.5 mph). Stability classes are determined from the vertical temperature difference between two measurement levels.
The generally open terrain around BFN does not cause any significant effects on the transport and dispersion of gaseous effluents from the plant. Within 30 kilometers of BFN, the terrain is mostly gently rolling hills (30-60 meters). Between 30 and 80 kilometers, the hills become larger to the north and south and mountainous to the east and northeast.
The Tennessee River/Wheeler Lake may have a minor effect on transport and dispersion in the immediate vicinity of BFN during periods of winds with a southerly component, overcast skies, and relatively high wind speeds. Also, the lower layer (10-45 meters) stability class tends to be more stable. However, during this infrequent condition, dose estimates will be conservative.
External Exposure Dose Dose calculated for maximum external air dose (gamma-air and beta-air) are made for points at and beyond the unrestricted area boundary as described in the BFN ODCM.
The highest of these doses is then selected.
Submersion Dose External doses to the skin and total body, due to submersion in a cloud of noble gases, are calculated for the nearest residence in each sector. The residence with the highest dose is then selected from all sectors.
E1-4
2011 Radiological Impact Assessment Report Organ Dose Dose to an organ due to releases of airborne effluents are estimated for the inhalation, ground contamination, and ingestion pathways. The ingestion pathway is further divided into three possible contributing pathways: ingestion of cow/goat milk, ingestion of beef, and ingestion of vegetables. Doses from applicable pathways are calculated for each receptor location identified in the most recent land use survey. To determine the maximum organ dose, the doses from the pathways are summed for each receptor.
However, for the ingestion dose, only those pathways that exist for each receptor are considered in the sum, e.g., milk ingestion doses are included only for locations where milk was consumed without commercial preparation and vegetable ingestion is included only for those locations where a garden was identified. To conservatively account for beef ingestion, a beef ingestion dose equal to that for the highest unrestricted area boundary location is added to each identified receptor. For ground contamination, the dose added to the organ dose being calculated is the total body dose calculated for that location, i.e., it is assumed that the dose to an individual organ is equal to the total body dose.
The maximum organ dose, thyroid dose, and total body dose from airborne effluents are presented in Tables 1, 2, 3, and 4.
V. DOSES FROM LIQUID EFFLUENTS For liquid effluents,.the public can be exposed to radiation from three sources: the ingestion of water from the Tennessee River, the ingestion of fish caught in the Tennessee River, and direct exposure from radioactive material deposited on the river shoreline sediment (recreation).
The concentration of radionuclides in the Tennessee River is calculated by a computer model which uses measured hydraulic data downstream of BFN. Parameters used to determine the doses are based on guidance given by the NRC for maximum ingestion rates, exposure times, etc. Wherever possible, parameters used in the dose calculation are site specific. The models that are used to estimate doses, as well as the parameters input to the models, are described in detail in the BFN ODCM.
Liquid Release Points and River Data Radionuclide concentrations in the Tennessee River are calculated assuming that releases in liquid effluents are continuous. When necessary, liquid releases from BFN, located at Tennessee River Mile 294, are made through diffusers which extend into the Tennessee River. It is assumed that releases to the river through these diffusers will initially be entrained in one-fifth of the water which flows past the plant. The QWATA code makes the assumption that this mixing condition holds true until the water is completely mixed at the first downstream dam (Wheeler Dam), at Tennessee River Mile 283.
Doses are calculated for locations within a 50 mile radius downstream of the plant site.
The maximum potential recreation dose is calculated for a location immediately downstream from the plant's release point. The maximum exposed individual dose from ingestion of fish is assumed to be that calculated for the consumption of fish caught E1-5
2011 Radiological Impact Assessment Report anywhere between the plant and the first downstream dam. The maximum exposed individual dose from drinking water is assumed to be that calculated at the nearest downstream public water supply [West Morgan - East Lawrence (WMEL)]. This could be interpreted as indicating that the maximum exposed individual, as assumed for liquid releases from BFN, is an individual who obtains all of his drinking water at WMEL, consumes fish caught from the Tennessee River between BFN and Wheeler Dam, and spends 500 hours0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> per year on the shoreline just downstream of the plant's release point.
Doses calculated for the maximum exposed individual due to liquid effluents for each quarter in the period are presented in Tables 5 and 6 along with the average river flows past the plant site for the periods. For the third and fourth quarter of 2011, there were no river releases.
VI. POPULATION DOSES Population doses due to airborne effluents are calculated for an estimated 778,266 people living within a 50-mile radius of the plant site. Doses from external pathways and inhalation are based on the 50-mile human population distribution. Ingestion population doses are calculated assuming that each individual consumed milk, vegetables, and meat produced within the sector in which the individual resides.
Population doses due to liquid effluents are calculated for the entire downstream Tennessee River population. Water ingestion population doses are calculated using actual population figures for downstream public water supplies. Fish ingestion population doses are calculated assuming that all sport fish caught in the Tennessee River are consumed by the Tennessee River population. Recreation population doses are calculated using historical recreational data on the number of shoreline visits at downstream locations.
Population doses calculated for airborne and liquid effluents are presented in Tables 1, 2, 3, 4, 5, and 6.
VII. OFFSITE DIRECT RADIATION DOSE External gamma radiation levels were measured by environmental dosimeters deployed around BFN as part of the offsite Radiological Environmental Monitoring Program (REMP). The quarterly gamma radiation levels determined from these dosimeters during this reporting period averaged approximately 19.3 mrem/quarter at onsite (at or near the site boundary) stations and approximately 16.8 mrem/quarter at offsite stations or approximately 2.5 mrem/quarter higher onsite than at offsite stations.
This difference is consistent with levels measured for pre-operation and construction phases of the Tennessee Valley Authority nuclear plants where the average radiation levels onsite were generally 2-6 mrem/quarter higher than the levels offsite. This may be attributable to natural variations in environmental radiation levels, earth moving activities onsite, the mass of concrete employed in the construction of the plants, or other undetermined influences. Fluctuations in natural background dose rates and in dosimeter readings tend to mask any small increments which may be due to plant operations. Thus, there was no identifiable increase in dose rate levels attributable to direct radiation from plant equipment and/or gaseous effluents.
E1-6
2011 Radiological Impact Assessment Report VIII. DOSE TO A MEMBER OF THE PUBLIC INSIDE THE SITE BOUNDARY Pursuant to ODCM Section 7.7.5, a review was performed ýto determine the highest dose to a member of the public in the site boundary. The dose to a member of the public consists of the sum of dose commitments from effluent releases as well as any direct radiation dose. The gaseous effluent dose commitment is negligible compared to the direct radiation dose.
The direct radiation dose was determined from area environmental dosimeters located onsite. It consisted of gamma dose from the plume, ground contamination, and from equipment sources (i.e., tanks, turbine shine, radioactive material storage areas, etc.).
The critical location was determined to be a Thermoluminescent Dosimeter near the Livewell Center (Training Center). The direct radiation dose accounting for background and occupancy was 0.81 mrem during 2011.
The total annual dose commitment to a member of the public for 2011 is 0.81 mrem. It can be concluded that the dose limit for a member of the public at the site boundary as specified in 10 CFR 20.1301 was not exceeded.
IX. TOTAL DOSE To determine compliance with 40 CFR 190, annual total dose contributions to the maximum exposed individual from BFN radioactive effluents and all other nearby uranium fuel cycle sources are considered.
The annual dose to any organ other than the thyroid for the maximum exposed individual is conservatively calculated by summing the following doses: the total body air submersion dose for each quarter, the critical organ dose (for any organ other than the thyroid) from airborne effluents for each quarter from ground contamination, inhalation and ingestion, the total body dose from liquid effluents for each quarter, the maximum organ dose (for any organ other than the thyroid) from liquid effluents for each quarter, and any identifiable increase in direct radiation dose levels as measured by the REMP.
This dose is compared to the 40 CFR 190 limit for total body or any organ dose (other than the thyroid) to determine compliance.
I The annual thyroid dose to the maximum exposed individual is conservatively estimated by summing the following doses: the total body air submersion dose for each quarter, the thyroid dose from airborne effluents for each quarter, the total body dose from liquid effluents for each quarter, the thyroid dose from liquid effluents for each quarter, and any identifiable increase in direct radiation dose levels as measured by the REMP. This dose is compared to the 40 CFR 190 limit for thyroid dose to determine compliance.
Total dose from the fuel cycle is presented in Table 7.
E1-7
2011 Radiological Impact Assessment Report Table 1 Doses from Airborne Effluents First Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air 1.6E-08 mrad 5 mrad
< 1%
NNW/1650 meters Beta Air 7.1E-09 mrad 10 mrad
< 1%
NNW/1650 meters Submersion Total Body 3.5E-04 mrem NA NA E/1290 meters Skin 4.2E-04 mrem NA NA E/1290 meters Organ Doses Child/Bone 1.5E-02 mrem 7.5 mrem
< 1%
NNW/1802 meters Child/Thyroid 2.1E-02 mrem 7.5 mrem
< 1%
NNW/1802 meters Child/Total Body 9.3E-03 mrem 7.5 mrem
< 1%
NNW/1802 meters Population Doses Total Body Dose
.1 E-01 man-rem Maximum Organ Dose (organ) 4.8E-01 man-rem (bone)
Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/ir for natural background).
E1-8
2011 Radiological Impact Assessment Report Table 2 Doses from Airborne Effluents Second Quarter*
Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air 8.8E-06 mrad 5 mrad
< 1%
NNE/1300 meters Beta Air 3.6E-06 mrad 10 mrad
< 1 %
NNE/1300 meters Submersion Total Body 9.1E-04 mrem NA NA N/2447 meters Skin 1.1E-03 mrem NA NA N/2447 meters Organ Doses Child/Bone 1.5E-02 mrem 7.5 mrem
< 1%
N/4580 meters Child/Thyroid 1.OE-02 mrem 7.5 mrem
<I %
NNW/1802 meters Child/Total Body 4.1E-03 mrem 7.5 mrem
<I %
NNW/4580 meters Population Doses Total Body Dose 8.OE-02 man-rem Maximum Organ Dose (organ) 3.6E-01 man-rem (bone)
Population doses can be compared to the natural background dose for the entire 50-mile population of about 70.044 man-rem/year (based on 90 mrem/yr for natural background).
- Includes dose from abnormal releases.
E1-9
2011 Radiological Impact Assessment Report Table 3 Doses from Airborne Effluents Third Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air 3.6E-10 mrad 5 mrad
< 1%
S/2250 meters Beta Air
- 1. IE-09 mrad 10 mrad
< 1 %
S/2250 meters Submersion Total Body 1.3E-03 mrem NA NA E/1290 meters Skin 1.5E-03 mrem NA NA E/1290 meters Organ Doses Child/Bone 3.4E-02 mrem 7.5 mrem
< 1%
NNW/1802 meters Child/Thyroid 1.6E-02 mrem 7.5 mrem
< 1%
NNW/1802 meters Child/Total Body 9.3E-03 mrem 7.5 mrem
< 1%
NNW/1802 meters Population Doses Total Body Dose 1.7E-01 man-rem Maximum Organ Dose (organ) 7.6E-01 man-rem (bone)
Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rein/year (based on 90 mnren/yr for natural background).
El-10
2011 Radiological Impact Assessment Report Table 4 Doses from Airborne Effluents Fourth Quarter Individual Doses Pathway Dose Quarterly Limit Percent of Limit Location External Gamma Air 3.6E-10 mrad 5 mrad
< 1%
NNW/1650 meters Beta Air 1.1E-09 mrad 10 mrad
< 1%
NNW/1650 meters Submersion Total Body 2.1E-04 mrem NA NA E/1290 meters Skin 2.5E-04 mrem NA NA E/1290 meters Organ Doses Child/ Bone 1.5E-02 mrem 7.5 mrem
< 1%
NNW/1802 meters Child/Thyroid 1.7E-02 mrem 7.5 mrem
< I%
NNW/1802 meters Child /Total Body 8.6E-03 mrem 7.5 mrem
< 1%
NNW/1802 meters Population Doses Total Body Dose 1.3E-01 man-rem Maximum Organ Dose (organ) 5.2E-01 man-rem (bone)
Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).
El-11
2011 Radiological Impact Assessment Report Table 5 Doses from Liquid Effluents First Quarter*
Individual Doses (mrem)
Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Adult Total Body Fish Ingestion 5.3E-04 Recreation 1.8E-04 Water Ingestion 2.OE-05 Total 7.3E-04 1.5 mrem
< 1%
Child Bone Fish Ingestion 7.9E-04 Recreation 1.8E-04 Water Ingestion 8.8E-05 Total 1.1E-03 5 mrem
< 1%
Child Thyroid Fish Ingestion 3.4E-06 Recreation 1.8E-04 Water Ingestion 1.7E-05 Total 2.OE-04 5 mrem
< 1%
Average Riverflow past BFN (cubic feet per second): 66423 Population Doses Total Body Dose 5.4E-03 man-rem Maximum Organ Dose (organ) 8.2E-03 man-rem (liver)
Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).
- Includes dose from abnormal releases.
E1-12
2011 Radiological Impact Assessment Report Table 6 Doses from Liquid Effluents Second Quarter Individual Doses (mrem)
Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Adult Total Body Fish Ingestion 2.OE-04 Recreation 3.1E-05 Water Ingestion 2.4E-05 Total 2.6E-04 1.5 mrem
< 1 %
Teen Liver Fish Ingestion 3.1 E-04 Recreation 3.1E-05 Water Ingestion 2.OE-05 Total 3.6E-04 5 mrem
< 1%
Child Thyroid Fish Ingestion 6.4E-07 Recreation 3.1E-05 Water Ingestion 2.8E-05 Total 6.OE-05 5 mrem
< 1%
Average Riverflow past BFN (cubic-feet per second): 49084 Population Doses Total Body Dose 2.6E-03 man-rem Maximum Organ Dose (organ) 3.6E-03 man-rem (liver)
Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).
E1-13
2011 Radiological Impact Assessment Report Table 7 Total Dose from Fuel Cycle First Second Third Fourth Dose Quarter Quarter Quarter Quarter Total Body or any Organ (except thyroid)
Total body air submersion 3.5E-04 9.1E-04 1.3E-03 2.IE-04 Critical organ dose (air) 1.5E-02 1.5E-02 3.4E-02 1.5E-02 Total body dose (liquid) 7.3E-04 2.6E-04 Maximum organ dose (liquid) 1.1E-03 3.6E-04 Direct Radiation Dose 0
0 0
0 Total 1.7E-02 1.7E-02 3.5E-02 1.5E-02 Cumulative Total Dose (mrem)
(Total body or any other organ) 8.4E-02 Annual Dose Limit (mrem) 2.5E+01 Percent of Limit
< 1%
Thyroid Dose (mrem)
Total body air submersion 3.5E-04 9.1E-04 1.3E-03 2.1E-04 Thyroid dose (airborne) 2.1E-02 1.OE-02 1.6E-02 1.7E-02 Total body dose (liquid) 7.3E-04 2.6E-04 Thyroid dose (liquid) 2.0E-04 6.OE-05 Direct Radiation Dose 0
0 0
0 Total 2.2E-03 1.1E-02 1.7E-02 1.7E-02 Cumulative Total Dose (Thyroid) mrem 4.7E-02 Annual Dose Limit (mrem) 7.5E+01 Percent of Limit
< 1%
E1-14 Browns Ferry Nuclear Plant Units 1, 2, and 3 2011 Meteorological Data Tables (See Attached)
E2-1
BROWNS FERRY NUCLEAR PLANT 2011 METEOROLOGICAL DATA TABLE 1 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES FIRST QUARTER E2-2
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (AT * -1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM -
0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.232 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.371 0.000 0.000 0.000 0.000 0.093 0.000 0.788 0.742 0.278 0.139 0.000 0.000 0.000 0.000 0.000 0.000 2.041 0.000 0.000 0.000 0.000 0.000 0.046 0.139 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.186 0.046 0.139 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.046 0.417 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.232 0.232 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 224.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.046 0.139 0.000 0.000 0.093 0.139
- 0. 974
- 0. 974 0.278 0.232 0.000 0.000 0.000 0.000 0.093 0.278 3.247 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2156 70 70 2156 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 5.53 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-3
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9 < AT * -1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH)
CALM 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.093 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.278 0.046 0.000 0.046 0.000 0.093 0.186 0.139 0.046 0.046 0.093 0.139 0.371 0.046 0.000 0.000 0.000 1.252 0.139 0.000 0.000 0.046 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 0.139 0.000 0.000 0.046 0.464 0.046 0.139 0.046 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.186 0.325 0.788 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.325 0.046 0.371 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000
'0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.232 0.139 0.093 0.046 0.093 0.232 0.232 0.093 0.139 0.186 0.139 0.417 0.186 0.000 0.510 0.417 3.154 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2156 68 68 2156 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 7.09 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-4
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7 < AT * -1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.139 0.139 0.046 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.417 0.046 0.000 0.000 0.046 0.000 0.093 0.046 0.093 0.139 0.000 0.139 0.093 0.093 0.046 0.046 0.093 0.974 0.046 0.093 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.046 0.139 0.093 0.093 0.139 0.093 0.835 0.093 0.186 0.139 0.046 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.046 0.139 0.093 0.417 0.278 1.531 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.139 0.000 0.186 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 No.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.186 0.278 0.139 0.093 0.093 0.093 0.278 0.232 0.186 0.000 0.278 0.278 0.325 0.278 0.742 0.464 3.942 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2156 85 85 2156 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 7.00 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-5
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5 < AT * -0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 N
NNE NE ENE E
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.232 0.417 0.139 0.325 0.371 0.232 0.510 0.696 0.603 0.835 0.417 0.093 0.139 0.093 0.046 0.232 0.649 0.974 1.531 1.252 0.603 0.974 0.835 0.371 0.371 0.186 0.371 0.510 0.974 0.371 0.835 0.649 0.974 0.974 1.067 0.835 0.325 0.139 0.093 0.093 0.000 0.046 0.232 0.232 0.742 0.510 0.696 1.020 1.206 0.974 0.881 0.232 0.046 0.371 0.139 0.000 0.000 0.000 0.000 0.417 0.974 1.020 3.200 3.061 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.186 1.345 1.855 0.464 3.850 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.186 0.000 0.186
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 3.061 3.340 3.618 2.644 1.391 1.716 1.577 1.160
- 0. 974 1.067 1.020 1.252 3.015 3.340 6.818 5.427 SUBTOTAL 5.380 11.456 7.978 12.523 0.000 41.419 TOTAL HOURS OF VALID STABILITY TOTAL HOURS OF STABILITY CLASS OBSERVATIONS D
TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2156 893 893 2156 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 7.09 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-6
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5 < AT
- 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.093 0.046 0.000 0.046 0.232 0.232 0.464 0.278 0.093 0.046 0.046 0.046 0.093 0.000 0.000 1.716 0.278 0.417 0.325 0.371 0.742 1.160 1.252 1.113 0.974 0.186 0.278
- 0. 603 0.325 0.093 0.139 0.278 8.534 0.371 0.974 0.742 0.371 0.325 0.742 0.788 0.649 1.113 0.417 0.464 0.232 0.649 0.186 0.232 0.186 8.442 0.186 0.371 0.325 0.093 0.000 0.186 0.325 0.046 0.510 0.928 0.139 0.232 0.186 0.046 0.046 0.464 4.082 0.139 0.093 0.278 0.000 0.000 0.000 0.093 0.000 0.232 0.464 0.000 0.000 0.093 0.093 0.510 0.232 2.226 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.974 1.948 1.716 0.835 1.113 2.319 2.690 2.273 3.108 2.087 0.928 1.113 1.299 0.557 0.928 1.206 0.000 25.093 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2156 541 541 2156 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 4.26 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-7
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F (1.5 < AT
- 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.232 0.093 0.093 0.046 0.046 0.186 0.232 0.557 0.232 0.186 0.000 0.139 0.046 0.000 0.000 0.046 2.134 0.881 0.278 0.093 0.557 0.742 0.974 1.670 1.623 1.067 0.417 0.278 0.093 0.046 0.000 0.000 0.186 8.905 0.139 0.464 0.093 0.093 0.232 0.139 0.278 0.000 0.881 0.186 0.000 0.000 0.000 0.000 0.000 0.093 2.597 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.371 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.557 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.186 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.186 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000.
0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.252 0.928 0.278 0.696 1.020 1.299 2.180 2.180 2.737 0.788 0.278 0.232 0.093 0.046 0.046 0.325 0.000 14.378 TOTAL HOURS OF VALID STABILITY TOTAL HOURS OF STABILITY CLASS OBSERVATIONS F
TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2156 310 310 2156 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 2.75 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-8
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (AT > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.005 0.002 0.002 0.001 0.002 0.001 0.005 0.017 0.008 0.001 0.000 0.001 0.000 0.000 0.000 0.001 0.046 12.5-18.4 18.5-24.4 0.139 0.093 0.186 0.186 0.232 0.139 0.603 1.345 0.232 0.093 0.000 0.093 0.000 0.046 0.000 0.139 3.525 0.649 0.278 0.232 0.000 0.046 0.046 0.325 1.531 1.113 0.000 0.000 0.000 0.000 0.000 0.046 0.093 4.360 0.186 0.139 0.000 0.000 0.000 0.000 0.000 0.000 0.278 0.000 0.000 0.000 0.000 0.000 0.046 0.093 0.742 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.979 0.512 0.420 0.187 0.280 0.187 0.933 2.893 1.724 0.093 0.000 0.093 0.000 0.047 0.093 0.326 8.766 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2156 189 189 2156 1
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 1.95 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-9
BROWNS FERRY NUCLEAR PLANT 2011 METEOROLOGICAL DATA TABLE 2 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES SECOND QUARTER E2-10
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (AT * -1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.323 0.739 0.600 0.416 0.231 0.000 0.000 0.000 0.000 0.000 2.401 0.046 0.000 0.000 0.000 0.092 0.231 0.369 0.092 0.416 0.877 0.369 0.462 0.185 0.092 0.000 0.000 3.232 0.046 0.092 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 0.000 0.139 0.323 0.092 0.046 0.000 0.831 0.092 0.000 0.092 0.000 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.185 0.092 0.185 0.231 0.185 1.154 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.185 0.000 0.185 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.185 0.092 0.092 0.046 0.092 0.416 0.693 0.831 1.016 1.339 0.600 0.785 0.600 0.369 0.462 0.185 7.802 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2166 169 169 2166 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 4.97 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-11
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9 < AT * -1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046
- 0. 323 0.277 0.416 0.323 0.185 0.092 0.046 0.000 0.000 0.000 1.708 0.000 0.092 0.092 0.000 0.000 0.000 0.277 0.000 0.139 0.369 0.046 0.231 0.046 0.092 0.000 0.000 1.385 0.092 0.139 0.046 0.000 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.185 0.185 0.046 0.092 0.185 1.062 0.185 0.185 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.139 0.323 0.277 0.139 1.293 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.139 0.000 0.231 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.277 0.416 0.139 0.000 0.000 0.139 0.600 0.277 0.554
- 0. 693 0.231 0.554 0.416 0.554 0.508 0.323 5.679 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2166 123 123 2166 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 5.87 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-12
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7 < AT * -1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.323 0.139 0.139 0.416 0.462 0.139 0.046 0.000 0.000 0.046 1.801 0.000 0.046 0.000 0.000 0.000 0.092 0.231 0.000 0.092 0.231 0.046 0.369 0.231 0.000 0.092 0.046 1.477 0.185 0.139 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.092 0.092 0.046 0.092 0.693 0.231 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.139 0.462
- 0. 600 0.185 1.754 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.092 0.092 0.277 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
-0
.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.416 0.231 0.046 0.000 0.046 0.139 0.554 0.139 0.231 0.693 0.508 0.554 0.508 0.646 0.831 0.462 6.002 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2166 130 130 2166 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 6.13 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-13
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5 < AT * -0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 N
NNE NE ENE E
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.139 0.231 0.046 0.046 0.231 0.877 1.016 1.108 2.632 2.078 1.108 0.923 0.554 0.139 0.046 0.185 0.231 0.231 0.185 0.092 0.092 0.462 0.231 0.046
- 0. 600 1.524 0.277
- 0. 600 0.416 0.508 0.277 0.369 6.140 0.462 0.277 0.092 0.139 0.139 0.092 0.000 0.000 0.139 0.231 0.046 0.369 0.785 0.554 1.108 0.554 4.986 0.092 0.185 0.092 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 0.092 0.877 1.524 1.801 1.062 5.817 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.600 0.877 0.046 1.524 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.185 0.000 0.185 12.5-18.4 18.5-24.4
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.923
- 0. 923 0.416 0.277 0.462 1.477 1.247 1.154 3.463 3.832 1.477
- 1. 985
- 2. 632 3.324 4.340 2.216 SUBTOTAL 0.139 11.357 0.000 30.148 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2166 653 653 2166 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 5.69 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-14
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5 < AT
- 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 N
NNE NE ENE E
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.092 0.231 0.092 0.092 0.277 0.323 0.277 0.139 0.092 0.092 0.092 0.000 0.092 0.000 0.554 0.462 0.092 0.416 1.016 1.616 0.739 1.154 1.893 2.355 0.646 0.646 0.739 0.185 0.092 0.416 0.369 0.323 0.231 0.046
- 0. 600 0.739 0.139 0.000 0.462 2.031 0.092 0.323 0.369 0.046 0.046 0.462 6.279 0.092 0.046 0.323 0.185 0.000 0.092 0.000 0.000 0.462 0.231 0.000 0.046 0.185 0.046 0.000 0.092 1.801 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.139 0.000 0.000 0.139 0.092 0.000 0.139 0.600 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 0.092 0.000 0.185 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.062 0.831 0.739 0.877 1.708 2.539 1.154 1.477 3.186 4.940 0.831 1.108 1.524 0.416 0.323 1.108 SUBTOTAL 1.939 13.019 0.000 23.823 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2166 516 516 2166 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 3.32 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-15
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F (1.5 < AT
- 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT APRIL 1, 2011 -
JUNE 30, 2011 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW CALM 0.004 0.001 0.001 0.004 0.008 0.008 0.004 0.002 0.004 0.003 0.001 0.001 0.001 0.001 0.001 0.003 0.046 0.277 0.092 0.231 0.739 0.693 0.785 0.277 0.277 0.185 0.231 0.185 0.000 0.139 0.185 0.139 0.185 1.108 0.231 0.139 0.693 2.031 1.754 0.923 0.231 1.154 0.877 0.185 0.185 0.046 0.046 0.277 0.646 0.231 0.323 0.046 0.277 0.277 0.000 0.000 0.000 0.185 0.046 0.000 0.000 0.046 0.000 0.000 0.046 1.477 0.000 0.000 0.092 0.092 0.000 0.000 0.000 0.000 0.323 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.554 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 0.000 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.620 0.647 0.509 1.805 3.009 2.547 1.204 0.509 1.851 1.250 0.370 0.185 0.231 0.278 0.417 0.880 SUBTOTAL 4.617 10.526 0.000 17.313 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2166 375 375 2166 1
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 2.31 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-16
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (AT > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.035 0.014 0.012 0.028 0.021 0.011 0.007 0.018 0.012 0.005 0.000 0.002 0.001 0.001 0.005 0.015 0.185 12.5-18.4 18.5-24.4 0.600 0.462 0.277 0.600 0.462 0.323 0.277 0.231 0.139 0.139 0.000 0.092 0.046 0.046 0.185 0.277 4.155 1.016 0.185 0.277 0.693 0.508 0.185 0.046 0.600 0.416 0.092 0.000 0.000 0.000 0.000 0.046 0.416 4.478 0.185 0.000 0.000 0:046 0.046 0.000 0.000 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.416 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.835 0.660 0.566 1.367 1.036 0.519 0.330 0.849 0.658 0.236 0.000 0.094 0.047 0.047 0.236 0.754 9.234 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2166 200 200 2166 4
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 1.72 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-17
BROWNS FERRY NUCLEAR PLANT 2011 METEOROLOGICAL DATA TABLE 3 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES THIRD QUARTER E2-18
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (AT ! -1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046
- 0. 697 1.209 1.023
- 0. 325
- 0. 093 0.000 0.000 0.000 0.000 0.000 3.440 0.046 0.046 0.000 0.000 0.046 0.465 1.860 0.837 0.372 0.232 0.279 0.279 0.186 0.000 0.046 0.000 4.695 0.093 0.093 0.093 0.000 0.046 0.465 0.046 0.000 0.000 0.000 0.000 0.093 0.232 0.046 0.000 0.093 1.302 0.790 0.325 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.232 0.279 0.046 0.186 1.906 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.325 0.186 0.511 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.930 0.465 0.139 0.000 0.139 0.976 2.603 2.046 1.395 0.558 0.372 0.372 0.651 0.325 0.418 0.465 0.000 11.855 TOTAL HOURS OF VALID STABILITY TOTAL HOURS OF STABILITY CLASS OBSERVATIONS A
TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2152 255 255 2151 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 5.32 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-19
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9 < AT * -1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.232 0.372 0.511 0.325 0.279 0.000 0.000 0.000 0.000 0.000 1.720 0.046 0.000 0.000 0.000 0.000 0.139 0.186 0.279 0.093 0.093 0.093 0.186 0.186 0.046 0.000 0.000 1.348 0.139 0.046 0.000 0.000 0.000 0.186 0.000 0.000 0.000 0.000 0.000 0.000 0.372 0.093 0.046 0.093 0.976 0.232 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.093 0.000 0.046 0.511 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.418 0.093 0.046 0.000 0.000 0.325 0.418 0.651 0.604 0.418 0.372 0.186 0.604 0.279 0.046 0.186 4.649 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM' 2152 100 100 2151 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 5.02 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-20
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7 < AT * -1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.093 0.372 0.511 0.418 0.232 0.139 0.000 0.093 0.000 0.000 0.046 1.953 0.093 0.046 0.046 0.000 0.046 0.232 0.139 0.046 0.186 0.046 0.139 0.372 0.465 0.139 0.232 0.000 2.232 0.139' 0.186 0.046 0.000 0.046 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.325 0.186 0.186 0.186 1.395 0.279 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.372 0.046 0.186 0.930 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.093
- 0. 046 0.232 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.511 0.279 0.093 0.000 0.139 0.418 0.511 0.558 0.604 0.279 0.279 0.372 0.883 0.790 0.558 0.465 6.741 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2152 145 145 2151 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 5.26 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-21
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5 < AT ! -0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 12.5-18.4 18.5-24.4 N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 0.000 0.139 0.000 0.093 0.000 0.000 0.000 0.046 0.000 0.000 0.139 0.139 0.186 0.279 0.418 0.744 0.976
- 1. 627 1.441 1.813 0.930 1.255 0.186 0.000 0.046 0.186 0.651 0.325 0.279 0.279 0.279 1.395 0.093 0.046 0.046 0.279 0.093
- 0. 930 1.488 0.697 0.418 0.465 7.764 0.325 0.558 0.186 0.093 0.372 0.651 0.000 0.000 0.000 0.000 0.000 0.046 0.837 0.465 0.790 0.232 4.556 0.186 0.279 0.093 0.000 0.093 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.186 0.744 1.023 2.696 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.418 0.046 0.465 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.302 1.302 0.790
- 0. 651 1.162 2.836 1.116 1.813 1.488 2.185 1.023 2.232 2.557 1.395 2.417 1.953 SUBTOTAL 0.000 0.372 10.367 0.000 26.220 TOTAL HOURS OF VALID STABILITY TOTAL HOURS OF STABILITY CLASS OBSERVATIONS D
TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2152 565 564 2151.0 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 4.61 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-22
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5 < AT < 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 N
NNE NE ENE E
WNW NW NNW CALM 0.006 0.004 0.005 0.007 0.009 0.007 0.008 0.004 0.010 0.006 0.006 0.007 0.007 0.001 0.002 0.003 0.093 12.'5-18.4 18.5-24.4 0.093 0.046 0.372 0.046 0.232 0.232 0.511 0.186 0.186 0.279 0.139 0.186 0.139 0.046 0.000 0.046 0.976 0.604 0.465 1.302 1.441 1.116 0.930 0.604 1.581 0.744 0.976 1.116 1.209 0.186 0.325 0.558 0.744 0.279 0.186 0.418 1.348 0.790 0.046 0.000 0.000 0.186 0.093 0.511 1.023 0.232 0.279 0.232 6.369 0.046 0.046 0.139 0.186 0.186 0.372 0.000 0.000 0.000 0.093 0.000 0.000 0.279 0.046 0.093 0.465 1.953 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.186 0.279 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.865 0.980 1.260 2.006 3.217 2.518 1.496 0.795 1.776 1.307 1.215 1.820 2.657 0.513 0.699 1.491 SUBTOTAL 2.743 14.133 0.000 25.616 TOTAL HOURS OF VALID STABILITY TOTAL HOURS OF STABILITY CLASS OBSERVATIONS E
TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2152 551 551 2151 2
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 3.05 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-23
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F (1.5 < AT
- 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.279 0.325 0.139 0.232 0.093 0.279 0.093 0.093 0.186 0.139 0.139 0.093 0.093 0.046 0.000 0.186 2.417 2.371 0.744 0.558 0.930 1.813 0.511 0.186 0.139 0.139 0.279 0.093 0.139 0.093 0.372 0.139 0.465 8.973 0.930 0.325 0.093 0.232 0.604 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.232 2.464 0.046 0.000 0.139 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.186 0.372 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 3.626 1.395 0.976 1.395 2.557 0.837 0.279 0.232 0.325 0.418 0.232 0.232 0.186 0.418 0.139 1.069 0.000 14.319 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2152 308 308 2151 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 2.62 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-24
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (AT > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 1.209 0.976 0.744 0.418 0.139 0.139 0.186 0.000 0.093 0.046 0.000 0.046 0.000 0.000 0.046 0.744 4.788 1.674 0.511 0.558 0.651 0.558 0.000 0.000 0.046 0.046 0.046 0.000 0.000 0.046 0.046 0.046 0.651 4.881 0.325 0.093 0.046 0.232 0.093 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.930 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 3.208 1.581 1.348 1.302 0.790 0.186 0.186 0.046 0.139 0.093 0.000 0.046 0.046 0.046 0.093 1.488 0.000 10.600 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2152 228 228 2151 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 1.89 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-25
BROWNS FERRY NUCLEAR PLANT 2011 METEOROLOGICAL DATA TABLE 4 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES FOURTH QUARTER E2-26
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (AT * -1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.546 0.046 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.865 0.000 0.000 0.000 0.000 0.000 0.091 0.865 0.820 0.410 0.455 0.091 0.182 0.000 0.000 0.000 0.000 2.914 0.046 0.000 0.000 0.000 0.046 0.228 0.137 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.501 0.091 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.182 0.046 0.000 0.319 0.774 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.137 0.137 0.000 0.000 0.046 0.319 1.138 1.366 0.455 0.592 0.091 0.228 0.182 0.046 0.046 0.319 5.100 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2196 112 112 2196 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 5.18 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-27
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9 < AT * -1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.228 0.182 0.046 0.000 0.000 0.046 0.000 0.000 0.000 0.592 0.000 0.000 0.000 0.000 0.000 0.182 0.091 0.137 0.182 0.000 0.000 0.137 0.091 0.000 0.000 0.000 0.820 0.046 0.000 0.000 0.000 0.000 0.046 0.091 0.000 0.000 0.091 0.000 0.000 0.000 0.091 0.000 0.000 0.364 0.273 0.046 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.182 0.046 0.000 0.046 0.638 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.319 0.046 0.000 0.000 0.000 0.273 0.273 0.364 0.364 0.137 0.000 0.137 0.319 0.228 0.000 0.046 2.505 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2196 55 55 2196 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 5.83 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-28
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7 < AT < -1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000.
0.046 0.000 0.182 0.091 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.364 0.000 0.000 0.000 0.000 0.046 0.091 0.228 0.182 0.046 0.046 0.046 0.046 0.091 0.046 0.000 0.000 0.865 0.091 0.046 0.046 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.091 0.046 0.046 0.501 0.137 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.228 0.455 0.228 0.228 1.366 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.046 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 224.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.228 0.091 0.046 0.046 0.091 0.182 0.228 0.364 0.137 0.091 0.046 0.046 0.364
- 0. 638 0.319 0.319 3.233 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2196 71 71 2196 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 6.81 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-29
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5 < AT * -0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.091 0.046 0.091 0.137 0.364 0.638 0.592 1.184 0.956 0.501 0.046 0.137 0.091 0.137 0.137 0.000 5.146 0.273 0.410 0.091 0.182 0.182 0.455
- 0. 638 0.729 0.455 0.501 0.592 0.319 0.455 0.455 0.364 0.546 6.648 0.956 0.956 0.137 0.046 0.091 0.137 0.046 0.000 0.273 0.091 0.091 0.273 0.911 0.319 0.911 1.321 6.557 1.047
- 0. 683 0.364 0.000 0.000 0.046 0.000 0.046 0.046 0.228 0.046 0.137 1.776 0.865 1.958 2.004 9.244 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.683 1.412 0.046 2.277 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 224.5 TOTAL 0.000 2.368 0.000 2.095 0.000 0.683 0.000 0.364 0.000 0.683 0.000 1.275 0.000 1.275 0.000 1.958 0.000 1.730 0.000 1.321 0.000 0.774 0.000 0.865 0.000 3.370 0.000 2.505 0.000 4.781 0.000 3.916 0.000 29.964 TOTAL HOURS OF VALID STABILITY TOTAL HOURS OF STABILITY CLASS OBSERVATIONS D
TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2196 658 658 2196 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 6.82 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-30
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5 < AT
- 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.091 0.000 0.000 0.000 0.046 0.091 0.228 0.000 0.000 0.000 0.091 0.046 0.091 0.046 0.000 0.000 0.729 0.410 0.410 0.182 0.455 0.865 0.956 1.412 1.685 1.366 0.319 0.228 0.501 0.319 0.364 0.273 0.228 9.973 0.592 0.273 0.182 0.319 0.683 0.683 0.865 0.410 2.368 0.455 0.137 0.364 1.047 0.182 0.364 0.410 9.335 0.228 0.091 0.046 0.000 0.000 0.273 0.410 0.000 0.865 0.228 0.000 0.000 0.273 0.137 0.410 0.364 3.324 0.091 0.182 0.000 0.000 0.000 0.091 0.000 0.000 0.046 0.046 0.000 0.000 0.137 0.182 0.364 0.273 1.412 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.046 0.182 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.412 0.956 0.410 0.774 1.594 2.095 2.914 2.095 4.645 1.047 0.455 0.911 1.867 0.911 1.548 1.321 0.000 24.954 TUTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2196 548 548 2196 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 4.07 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-31
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F (1.5 < AT
- 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND DIRECTION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 N
NNE NE ENE E
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.091 0.000 0.046 0.228 0.137 0.137 0.546 0.410 0.091 0.046 0.046 0.000 0.046 0.046 0.046 0.000 1.184 0.319 0.319 0.820 1.594 1.685 0.865 1.594 1.821 0.137 0.091 0.000 0.046 0.046 0.410 0.546 0.592 0.546 0.364 0.455 0.774 0.182 0.046 0.091 1.503 0.091 0.000 0.000 0.000 0.046 0.091 0.319 5.100 0.046 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.182 0.000 0.000 0.000 0.000 0.000 0.000 0.228 0.546 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0,000 0.000 0,000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.913 0.956 0.729 1.548 2.505 2.004 1.457 2.095 3.597 0.273 0.137 0.000 0.091 0.137 0.546 1.093 SUBTOTAL 1.913 11.475 0.000 19.080 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2196 419 419 2196 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 2.89 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-32
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (AT > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.020 0.010 0.007 0.011 0.005 0.002 0.003 0.008 0.007 0.000 0.000 0.000 0.000 0.000 0.004 0.014 0.091 0.865
- 0. 683 0.410 0.455 0.182 0.091 0.182 0.410 0.182 0.046 0.000 0.000 0.046 0.000 0.501 0.774 4.827 2.095 0.774 0.683 1.184 0.592 0.273 0.228 0.820 0.865 0.000 0.000 0.000 0.000 0.046 0.091 1.321 8.971 0.729 0.182 0.137 0.091 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 1.230 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 o.0oo 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 3.708 1.695 1.237 1.741 0.779 0.367 0.413 1.238 1.100 0.046 0.000 0.000 0.046 0.046 0.596 2.154 0.000 15.164 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2196 333 333 2196 2
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED = 2.03 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-33
BROWNS FERRY NUCLEAR PLANT 2011 METEOROLOGICAL DATA TABLE 5 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL RELEASE MODE AND ELEVATED RELEASE MODE)
FIRST QUARTER E2-34
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (AT * -1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.012 0.000 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.016 0.000 0.000 0.000 0.000 0.004 0.000 0.113 0.143 0.018 0.014 0.000 0.000 0.000 0.000 0.000 0.000 0.292 0.000 0.000 0.000 0.000 0.000 0.007 0.058 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.065 0.007 0.019 0.000 0.000 0.000 0.009 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.015 0.009 0.068 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.065 0.065 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.007 0.019 0.000 0.000 0.004 0.017 0.180 0.154 0.018 0.019 0.000 0.000 0.000 0.000 0.015 0.074 0.507 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2156.000 291.180 16.480 10.930 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-35
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9 < AT * -1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM
Ž24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.007
- 0. 002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.012 0.000 0.000 0.000 0.000 0.001 0.002 0.011 0.000 0.000 0.006 0.017 0.031 0.005 0.000 0.000 0.000 0.074 0.018 0.000 0.000 0.002 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.006 0.012 0.000 0.000 0.005 0.051 0.006 0.018 0.005 0.000 0.000 0.023 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.032 0.056 0.139 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.064 0.010 0.073 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.023 0.018 0.005 0.002 0.001 0.025 0.021 0.007 0.002 0.006 0.017 0.037 0.017 0.000 0.095 0.071 0.349 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 2156.000 291.180 12.680 7.530 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-36
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7 < AT * -1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.000 0.000 0.000 0.000 0.000 0.006 0.000 0.032 0.011 0.000 0.003 0.009 0.000 0.000 0.000 0.000 0.062 0.001 0.008 0.000 0.000 0.010 0.000 0.000 0.000 0.000 0.000 0.008 0.019 0.006 0.003 0.011 0.008 0.074 0.015 0.025 0.020 0.006 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.008 0.024 0.012 0.062 0.044 0.267 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.013 0.027 0.000 0.041 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.016 0.033 0.020 0.007 0.010 0.006 0.056 0.037 0.011 0.000 0.011 0.036 0.029 0.028 0.100 0.053 0.454 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 2156.000 291.180 36.600 9.780 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-37
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5 < AT * -0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.000 0.000 0.000 0.006 0.000 0.021 0.007 0.018 0.016 0.009 0.000 0.005 0.000 0.000 0.000 0.084 0.041 0.049 0.049 0.048 0.029 0.115 0.237 0.266
- 0. 058 0.031 0.027 0.040 0.040 0.005 0.006 0.018 1.057 0.122 0.115 0.105 0.075 0.037 0.029 0.081 0.093 0.000 0.009 0.044 0.030 0.080 0.031 0.056 0.106 1.012 0.220 0.160 0.127 0.030 0.008 0.164 0.097 0.000 0.000 0.000 0.000 0.078 0.179 0.158 0.501 0.503 2.225 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.060 0.422 0.451 0.140 1.072 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.143 0.000 0.143
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.385 0.324 0.281 0.153 0.080 0.307 0.436 0.366 0.076 0.056 0.079 0.148 0.364 0.615 1.156 0.767 5.593 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 2156.000 291.180 1005.710 120.590 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-38
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5 < AT
- 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.009 0.004 0.003 0.003 0.000 0.000 0.000 0.000 0.000 0.000 0.021 0.015 0.020 0.010 0.015 0.037 0.079 0.108 0.145 0.083 0.013 0.013 0.035 0.012 0.000 0.000 0.003 0.590 0.041 0.103 0.070 0.037 0.038
- 0. 105 0.182 0.461 0.214 0.072 0.076 0.026 0.062 0.010 0.010 0.014 1.522 0.029 0.054 0.042 0.013 0.000 0.033 0.241 0.046 0.141 0.204 0.028 0.041 0.029 0.006 0.006 0.066 0.978 0.025 0.017 0.046 0.000 0.000 0.000 0.085 0.000 0.179 0.260 0.000 0.000 0.018 0.015 0.091 0.040 0.776 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.018 0.000 0.010 0.027 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.111 0.194 0.168 0.065 0.076 0.219 0.625 0.657
- 0. 620 0.553 0.116 0.102 0.121 0.048 0.108 0.133 3.916 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 2156.000 291.180 704.110 84.420 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-39
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F (1.5 < AT
- 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-i2.4 12.5-18.4 CALM 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.005 0.006 0.010 0.028 0.017 0.013 0.000 0.001 0.002 0.000 0.000 0.000 0.082 0.054 0.009 0.000 0.015 0.054 0.088 0.180 0.348 0.164 0.039 0.014 0.004 0.002 0.000 0.000 0.014 0.985 0.018 0.058 0.010 0.011 0.019 0.023 0.052 0.000 0.168 0.030 0.000 0.000 0.000 0.000 0.000 0.013 0.402 0.000 0.017 0.000 0.000 0.000 0.000 0.000 0.000 0.130 0.000 0.000 0.000 0.000 0.008 0.007 0.000 0.162 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.170 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.170 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.071 0.083 0.010 0.028 0.078 0.116 0.243 0.376 0.650 0.082 0.014 0.005 0.004 0.008 0.007 0.027 1.801 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 2156.000 291.180 295.720 38.840 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-40
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (AT > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.002 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.000 0.000 0.000 0.000 0.000 0.006 0.059 0.137 0.034 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.237 0.012 0.007 0.004 0.000 0.004 0.004 0.037 0.212 0.194 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.474 0.025 0.013 0.000 0.000 0.000 0.000 0.000 0.000 0.054 0.000 0.000 0.000 0.000 0.000 0.007 0.013 0.112 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.058 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.058 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.038 0.020 0.004 0.000 0.004 0.010 0.097 0.352 0.342 0.000 0.000 0.000 0.000 0.000 0.007 0.013 0.885 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 2156.000 291.180 84.700 19.090 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-41
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (AT * -1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.084 0.082 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.167 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.129 0.082 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.257 HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 2156.000 1864.820 16.480 5.550 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-42
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9 < AT * -1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.085 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.085 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.015 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.015
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.061 0.131 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.239 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 2156.000 1864.820 12.680 5.150 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-43
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7 < AT * -1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 18.5-24.4
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.089 0.178 0.046 0.000 0.046 0.000 0.132 0.000 0.000 0.000 0.000 0.492 0.080 0.040 0.000 0.000 0.000 0.039 0.041 0.041 0.000 0.000 0.000 0.041 0.000 0.000 0.000 0.000 0.282 0.000 0.000 0.000 0.000 0.000 0.037 0.000 0.000 0.000 0.077 0.000 0.000 0.000 0.037 0.113 0.113 0.377 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.080 0.040 0.000 0.000 0.000 0.165 0.266 0.087 0.000 0.170 0.000 0.173 0.000 0.037 0.113 0.113 1.244 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 2156.000 1864.820 36.600 26.820 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-44
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5 < AT * -0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 18.5-24.4 N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.046 0.093 0.046 0.046 0.139 0.139 0.186 0.186 0.093 0.046 0.000 0.000 0.046 0.046 0.046 1.252 0.278
- 0. 603 0.278 0.464 0.464 0.557 0.417 0.232 0.232 0.186 0.417 0.232 0.417 0.510 0.510 0.278 6.076 0.537 0.488 0.847 0.892 0.619 0.408 0.178 0.091 0.313 0.271 0.445 0.220 0.763 0.354 0.577 0.529 1.567 1.661 1.514 0.783 0.622 0.859 0.399 0.243 0.161 0.332 0.694 0.988 0.614 1.172 2.128 1.682 0.983 0.421 0.000 0.000 0.038 0.299 0.152 0.113 0.115 0.114 0.379 0.415 0.944 1.313 1.848 1.553 8.686 0.035 0.000 0.000 0.000 0.000 0.103 0.274 0.043 0.000 0.000 0.000 0.000 0.183 0.631 0.442 0.306 2.016 224.5 0.000 0.000 0.000 0.000 0.000 0.000 0.029 0.012 0.000 0.000 0.000 0.000 0.000 0.000 0.031 0.000 TOTAL 3.493 3.220 2.732 2.186 1.789 2.364 1.588 0.920 1.006 0.994 1.982 1.855 2.922 4.026 5.582 4.395 SUBTOTAL 7.532 15.420 0.072 41.054 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2156.000 1864.820 1005.710 885.120 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-45
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5 < AT < 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE JANUARY 1, 2011 -
MARCH 31, 2011 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0-000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 0.093 0.093 0.325 0.232 0.139 0.093 0.000 0.046 0.000 0.046 0.046 0.139 0.046 1.345 0.046 0.046 0.093 0.139 0.093 0.278 0.186 0.325 0.325 0.325 0.278 0.046 0.093 0.139 0.186 0.139 2.737 0.312 0.482 0.618 0.403 0.442 0.629 0.354 0.629 0.487 0.315 0.717 0.264 0.400 0.132 0.046 0.180 0.731 1.250 0.911 0.210 0.370 0.944 1.008 0.524 0.571 0.686 0.986 0.629 0.579 0.160 0.359 0.608 0.113 0.152 0.192 0.000 0.000 0.267 1.435 0.522 1.167 0.978 0.528 0.304 0.000 0.076 0.342 0.191 6.267 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.016 0.256 0.163 0.419 0.419 0.034 0.000 0.000 0.000 0.000 0.000 1.307
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.007 0.044 0.019 0.014 0.006 0.000 0.000 0.009 0.000 0.000 0.000 TOTAL 1.203 1.931 1.861 0.845 1.044 2.467 3.514 2.322 3.077 2.729 2.590 1.244 1.127 0.554 1.071 1.165 SUBTOTAL 6.412 10.528 0.100 28.743 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 2156.000 1864.820 704.110 619.690 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-46
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F (1.5 < AT
- 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.186 0.000 0.046 0.000 0.046 0.046 0.046 0.093 0.046 0.139 0.046 0.046 0.000 0.000 0.000 0.788 0.046 0.000 0.000 0.093 0.093 0.186 0.046 0.371 0.232 0.093 0.186 0.000 0.046 0.046 0.232 0.093 1.763 0.089 0.089 0.045 0.179 0.090 0.225 0.267 0.404 0.224 0.219 0.538 0.045 0.046 0.000 0.044 0.044 2.547 0.410 0.163 0.083 0.327 0.332 0.454 1.143 0.202 0.880 0.623 0.212 0.000 0.000 0.000 0.039 0.122 4.988 0.038 0.038 0.000 0.000 0.000 0.000 0.267 0.412 0.606 0.115 0.000 0.000 0.000 0.000 0.000 0.038 1.515 0.000 0.000 0.000 0.000 0.000 0.000 0.076 0.072 0.108 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.256
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.629 0.475 0.128 0.691 0.514 0.910 1.856 1.508 2.142 1.097 1.075 0.092 0.139 0.046 0.314 0.298 0.010 11.915 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 2156.000 1864.820 295.720 256.880 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-47
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (AT > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.046 0.000 0.093 0.046 0.046 0.093 0.139 0.093 0.000 0.046 0.046 0.000 0.093 0.000 0.000 0.000 0.742 0.000 0.000 0.046 0.000 0.046 0.046 0.046 0.046 0.000 0.093 0.093 0.046 0.093 0.000 0.000 0.000 0.557 0.045 0.000 0.087 0.000 0.046 0.000 0.046 0.046 0.135 0.088 0.178 0.000 0.000 0.000 0.000 0.044 0.716 0.000 0.000 0.041 0.043 0.000 0.000 0.000 0.000 0.164 0.168 0.043 0.000 0.000 0.000 0.000 0.000 0.459 0.000 0.000 0.000 0.000 0.000 0.000 0.038 0.226 0.228 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.492 0.000 0.000 0.000 0.000 0.000 0.000 0.032 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.032
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.092 0.000 0.267 0.089 0.139 0.139 0.301 0.411 0.527 0.396 0.360 0.046 0.186 0.000 0.046 0.044 3.043 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 2156.000 1864.820 84.700 65.610 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-48
BROWNS FERRY NUCLEAR PLANT 2011 METEOROLOGICAL DATA TABLE 6 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL RELEASE MODE AND ELEVATED RELEASE MODE)
SECOND QUARTER E2-49
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (AT * -1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.023 0.000 0.000 0.025 0.054 0.075 0.052 0.006 0.000 0.000 0.000 0.000 0.000 0.234 0.001 0.000 0.000 0.000 0.009 0.022 0.029 0.005 0.039 0.159 0.035 0.057 0.006 0.004 0.000 0.000 0.365 0.006 0.009 0.000 0.000 0.000 0.008 0.000 0.000 0.000 0.009 0.000 0.019 0.033 0.006 0.002 0.000 0.093 0.014 0.000 0.012 0.000 0.000 0.036 0.000 0.000 0.000 0.000 0.000 0.026 0.014 0.030 0.036 0.027 0.195 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.041 0.000 0.041 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.020 0.009 0.012 0.023 0.009 0.065 0.055 0.058 0.114 0.221 0.041 0.101 0.053 0.040 0.080 0.027 0.928 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2138.000 248.640 32.540 19.850 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-50
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9 < AT * -1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.013 0.028 0.017 0.009 0.006 0.000 0.000 0.000 0.000 0.075 0.000 0.000 0.001 0.000 0.000 0.000 0.018 0.000 0.010 0.058 0.007 0.012 0.003 0.000 0.000 0.000 0.109 0.009 0.011 0.002 0.000 0.000 0.026 0.000 0.000 0.000 0.000 0.000 0.023 0.020 0.002 0.008 0.017 0.117 0.028 0.027 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.023 0.056 0.038 0.022 0.203 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.018 0.031 0.000 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 224. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.036 0.038 0.004 0.000 0.000 0.026 0.020 0.013
- 0. 038 0.075 0.016 0.049 0.046 0.076 0.077 0.039 0.553 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 2138.000 248.640 34.990 11.830 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-51
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7 < AT * -1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.012 0.007 0.014 0.026 0.006 0.000 0.000 0.000 0.000 0.000 0.071 0.000 0.001 0.000 0.000 0.000 0.012 0.004 0.000 0.014 0.034 0.000 0.015 0.007 0.000 0.000 0.000 0.087 0.020 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.013 0.003 0.005 0.012 0.063 0.034 0.008 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.023 0.071 0.093 0.031 0.276 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.019 0.018 0.047 0.085 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.054 0.019 0.008 0.000 0.000 0.018 0.015 0.007 0.028 0.060 0.006 0.024 0.044 0.094 0.116 0.090 0.582 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 2138.000 248.640 116.910 12.440 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-52
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5 < AT * -0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.017, 0.075 0.055 0.055 0.192 0.209 0.069 0.012 0.012 0.000 0.000 0.000 0.696 0.010 0.005 0.003 0.002 0.011 0.097 0.035 0.006 0.117 0.343 0.028 0.045 0.022 0.011 0.005 0.013 0.752 0.058 0.032 0.007 0.011 0.023 0.019 0.000 0.000 0.051 0.092 0.009 0.053 0.099 0.037 0.089 0.057 0.638 0.017 0.030 0.016 0.000 0.000 0.010 0.000 0.000 0.000 0.000 0.047 0.018 0.117 0.215 0.292 0.164 0.926 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.111 0.255 0.023 0.390 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.109 0.000 0.109
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.086 0.067 0.027 0.013 0.051 0.200 0.090 0.060 0.361 0.644 0.152 0.128 0.249 0.375 0.750 0.256 3.509 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS GROUND LEVEL RELEASE STABILITY CLASS D GROUND LEVEL STABILITY CLASS D 2138.000 248.640 860.580 75.030 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-53
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5 < AT
- 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.006 0.000 0.003 0.009 0.002 0.012 0.000 0.000 0.002 0.000 0.000 0.002 0.000 0.036 0.030 0.007 0.002 0.010 0.076 0.173 0.077 0.103 0.250 0.345 0.054 0.034 0.036 0.002 0.000 0.011 1.210 0.045 0.026 0.014 0.005 0.085 0.122 0.033 0.000 0.108 0.656 0.013 0.043 0.033 0.004 0.000 0.046 1.234 0.016 0.006 0.050 0.025 0.000 0.035 0.000 0.000 0.275 0.074 0.000 0.008 0.024 0.007 0.000 0.012 0.531 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.094 0.000 0.000 0.008 0.005 0.000 0.025 0.222 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
-0.000 0.047 0.000 0.000 0.000 0.000 0.037 0.000 0.084 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.091 0.038 0.066 0.046 0.161 0.333 0.119 0.105 0.737 1.215 0.067 0.087 0.101 0.018 0.039 0.094 3.317 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS.
HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 2138.000 248.640 624.910 70.920 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-54
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F (1.5 < AT
- 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 18.5-24.4 0.000 0.000 0.000 0.000 0.001 0.000 0.000 0.000 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.003 0.014 0.009 0.024 0.045 0.058 0.046 0.014 0.007 0.013 0.019 0.000 0.000 0.007 0.009 0.007 0.000 0.273 0.088 0.024 0.014 0.053 0.160 0.163 0.088 0.022 0.271 0.164 0.019 0.031 0.000 0.000 0.008 0.034 1.139 0.029 0.047 0.007 0.031 0.023 0.000 0.000 0.000 0.078 0.019 0.000 0.000 0.005 0.000 0.000 0.007 0.246 0.000 0.000 0.014 0.014
- 0. 0o0 0.000 0.000 0.000 0.266 0.016 0.000 0.000 0.000 0.000 0.000 0.000 0.311 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.131 0.080 0.060 0.144 0.242 0.210 0.102 0.029 0.628 0.257 0.019 0.031 0.012 0.009 0.015 0.042 2.010 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 2138.000 248.640 393.060 42.980 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10-50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-55
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (AT > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.001 0.000 0.000 0.001 0.001 0.001 0.000 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.009 18.5-24.4 0.006 0.000 0.022 0.070 0.036 0.039 0.032 0.029 0.019 0.014 0.000 0.000 0.000 0.008 0.000 0.001 0.278 0.074 0.007 0.007 0.022 0.052 0.010 0.003 0.073 0.076 0.023 0.000 0.000 0.000 0.000 0.001 0.010 0.359 0.019 0.000 0.000 0.006 0.002 0.000 0.000 0.000 0.049 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.083 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.100 0.008 0.029 0.099 0.092 0.050 0.036 0.103 0.145 0.038 0.000 0.000 0.000 0.009 0.001 0.018 0.729 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 2138.000 248.640 75.010 15.590 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-56
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (AT
- -1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.088 0.000 0.000 0.134 0.043 0.000 0.000 0.000 0.000 0.266 0.000 0.000 0.000 0.000 0.000 0.000 0.042 0.085 0.000 0.040 0.083 0.041 0.000 0.000 0.000 0.000 0.290 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.037 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.037 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.042 0.174 0.037 0.040 0.217 0.085 0.000 0.000 0.000 0.000 0.594 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 2138.000 1889.360 32.540 12.690 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-57
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9 < AT * -1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.186 0.040 0.000 0.000 0.000 0.000 0.000 0.042 0.124 0.166 0.000 0.288 0.041 0.000 0.042 0.000 0.000 0.742 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.037 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.037 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.034 0.000 0.000 0.000 0.000 0.037 0.000 0.000 0.071
Ž24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.040 0.000 0.000 0.000 0.000 0.093 0.089 0.124 0.283 0.046 0.288 0.041 0.000 0.079 0.000 0.000 1.083 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 2138.000 1889.360 34.990 23.160 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-58
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7 < AT * -1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.140 0.000 0.140 0.140 0.187 0.047 0.047 0.000 0.000 0.000 0.702 0.000 0.092 0.000 0.000 0.000 0.045 0.136 0.000 0.046 0.000 0.044 0.045 0.270 0.090 0.088 0.000 0.857 0.161 0.334 0.081 0.000 0.000 0.043 0.041 0.000 0.166 0.161 0.165 0.245 0.124 0.083 0.120 0.167 1.891 0.078 0.000 0.000 0.000 0.000 0.000 0.038 0.077 0.193 0.038 0.000 0.268 0.075 0.267 0.076 0.155 1.266 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.104 0.000 0.000 0.000 0.000 0.000 0.066 0.000 0.171
Ž24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.239 0.427 0.081 0.000 0.000 0.088 0.355 0.077
- 0. 649 0.340 0.396 0.605 0.516 0.441 0.350 0.321 4.886 TOTAL TOTAL TOTAL TOTAL HOURS HOURq HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 2138.000 1889.360 116.910 104.470 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-59
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5 < AT * -0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0.047 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.234 0.000 0.140 0.047 0.094 0.047 0.047 0.281 0.374 0.327 0.421 0.374 0.421 0.187 0.000 0.094 0.047 2.900 0.094 0.140 0.140 0.094 0.000 0.421 0.842 0.094 0.561 0.655 0.702 0.655 0.468 0.374 0.374 0.140 5.753 0.181 0.402 0.229 0.088 0.044 0.361 0.406 0.540 0.583 0.449 0.958 0.446 0.366 0.626 0.316 0.446 6.441 1.061 0.413 0.080 0.042 0.042 0.169 0.450 1.176 1.223
- 1. 630 0.905 0.569 1.187 1.384 1.143 1.140 12.614 0.077 0.116 0.076 0.000 0.000 0.188 0.191 0.574 1.600 0.802 0.189 0.230 0.344 1.182
- 1. 605 0.230 7.404 0.000 0.000 0.000 0.000 0.000 0.000 0.094 0.150 0.651 0.130 0.000 0.033 0.000 0.131 0.156 0.024 1.368
Ž24.5 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.020 0.000 TOTAL 1.421 1.212 0.572 0.317 0.132 1.279 2.309 2.908 4.992 4.133 3.128 2.354 2.551 3.698 3.708 2.027 0.029 36.742 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2138.000 1889.360 860.580 785.550 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-60
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5 < AT
- 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.234 0.000 0.187 0.000 0.000 0.094 0.000 0.187 0.374 0.327 0.187 0.047 0.047 0.000 0.094 1.824 0.094 0.094 0.140 0.047 0.047 0.047 0.327 0.421 0.374 0.935 0.608 0.140 0.094 0.140 0.047 0.234 3.789 0.358 0.271 0.271 0.000 0.089 0.182 0.487 0.451 0.493 0.492 0.492 0.316 0.357 0.045 0.093 0.137 4.535 0.371 0.246 0.201 0.082 0.371 0.410 2.062 1.278 1.307 1.305 0.501 0.376 0.415 0.000 0.291 0.409 9.625 0.038 0.038 0.039 0.000 0.000 0.077 0.384 0.951 2.086 0.762 0.078 0.038 0.039 0.000 0.037 0.037 4.603 0.000 0.000 0.000 0.000 0.000 0.000 0.085 0.318 0.772 0.264 0.000 0.000 0.019 0.000 0.012 0.000 1.471
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.048 0.008 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL
- 0. 908 0.883
- 0. 651 0.316 0.507 0.715 3.438 3.428 5.268 4.141 2.007 1.058 0.971 0.232 0.480 0.910 0.065 25.912 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 2138.000 1889.360 624.910 553.990 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-61
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F (1.5 < AT
- 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.140 0.000 0.094 0.140 0.140 0.047 0.094 0.094 0.187 0.094 0.187 0.094 0.094 0.094 0.094 0.047 0.047 1.543 0.140 0.234 0.187 0.140 0.047 0.281 0.281 0.140 0.187 0.281 0.374 0.047 0.047 0.000 0.187 0.234 2.806 0.047 0.180 0.045 0.000 0.044 0.271 0.991 0.406 0.538 0.355 0.046 0.000 0.000 0.045 0.137 0.452 3.558 0.543 0.833 0.245 0.448 0.328 0.541 1.161 0.691 1.515 0.456 0.042 0.000 0.042 0.000 0.000 0.161 7.006 0.000 0.000 0.039 0.000 0.000 0.000 0.038 0.495 0.569 0.000 0.000 0.000 0.039 0.000 0.000 0.000 1.179 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.037 0.104 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.141
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.730 1.341 0.656 0.729 0.513 1.187 2.564 1.956 3.007 1.278 0.555 0.187 0.268 0.139 0.371 0.894 0.000 16.374 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 2138.000 1889.360 393.060 350.080 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-62
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (AT > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL IWIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.047 0.094 0.094 0.047 0.000 0.000 0.047 0.468 0.000 0.000 0.094 0.094 0.047 0.047 0.047 0.047 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.047 0.514 0.045 0.043 0.134 0.270 0.090 0.091 0.044 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.044 0.809 0.000 0.247 0.247 0.041 0.000 0.000 0.251 0.081 0.081 0.041 0.000 0.000 0.000 0.000 0.000 0.000 0.988 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.045 0.337 0.475 0.405 0.137 0.138 0.388 0.221 0.081 0.134 0.140 0.094 0.047 0.000 0.000 0.138 2.779 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 2138.000 1889.360 75.010 59.420 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-63
BROWNS FERRY NUCLEAR PLANT 2011 METEOROLOGICAL DATA TABLE 7 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL RELEASE MODE AND ELEVATED RELEASE MODE)
THIRD QUARTER E2-64
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (AT * -1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>24.5 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.026 0.051 0.058 0.024 0.002 0.000 0.000 0.000 0.000 0.000 0.161 0.001 0.003 0.000 0.000 0.004 0.039 0.136 0.021 0.023 0.007 0.005 0.005 0.013 0.000 0.002 0.000 0.259 0.010 0.007 0.004 0.000 0.005 0.080 0.008 0.000 0.000 0.000 0.000 0.009 0.022 0.004 0.000 0.008 0.157 0.166 0.075 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.032 0.036 0.009 0.030 0.354 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.072 0.065 0.136 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.177 0.084 0.010 0.000 0.009 0.119 0.170 0.072 0.081 0.031 0.007 0.014 0.067 0.040 0.083 0.104 1.067 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2067.000 131.030 67.780 22.060 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-65
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND-SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9 < AT * -1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.003 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.014 0.000 0.000 0.000 0.000 0.000 0.008 0.001 0.000 0.000 0.000 0.000 0.004 0.008 0.001 0.000 0.000 0.023 0.018 0.009 0.000 0.000 0.000 0.030 0.000 0.000 0.000 0.000 0.000 0.000 0.028 0.008 0.004 0.008 0.104 0.066 0.007 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.016 0.000 0.009 0.112 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.000 0.015 0.025 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.085 0.015 0.006 0.000 0.000 0.039 0.007 0.003 0.006 0.000 0.000 0.004 0.043 0.035 0.004 0.032 0.279 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 2067.000 131.030 63.930 5.760 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-66
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7 < AT ! -1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.000 0.000 0.000 0.006 0.000 0.000 0.000 0.000 0.000 0.014 0.005 0.0-00 0.000 0.000 0.003 0.020 0.013 0.000 0.000 0.000 0.000 0.005 0.001 0.001 0.002 0.000 0.049 0.017 0.012 0.005 0.000 0.006 0.015 0.000 0.000 0.000 0.000 0.000 0.000 0.029 0.011 0.016 0.014 0.125 0.065 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.049 0.007 0.027 0.158 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.019 0.022 0.017 0.058 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.087 0.022 0.005 0.000 0.009 0.035 0.020 0.000 0.000 0.000 0.006 0.005 0.030 0.080 0.047 0.058 0.403 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 2067.000 131.030 112.740 8.340 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-67
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5 < AT * -0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.000 0.000 0.000 0.000 0.000 0.027 0.028 0.024 0.058 0.038 0.020 0.005 0.000 0.000 0.000 0.000 0.200 0.036 0.003 0.001 0.010 0.024 0.233 0.010 0.000 0.034 0.028 0.000 0.044 0.043 0.007 0.002 0.016 0.490 0.031 0.069 0.021 0.008 0.052 0.133 0.000 0.000 0.000 0.000 0.000 0.006 0.057 0.039 0.059 0.024 0.498 0.037 0.068 0.012 0.000 0.009 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.008 0.031 0.119 0.189 0.482 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.100 0.010 0.110 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.104 0.139 0.033 0.018 0.085 0.392 0.046 0.029 0.092 0.066 0.020 0.055 0.108 0.077 0.279 0.240 1.786 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 2067.000 131.030 808.120 36.920 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-68
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5 < AT
- 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.003 0.000 0.000 0.006 0.005 0.000 0.000 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.021 0.034 0.012 0.007 0.020 0.082 0.044 0.034 0.014 0.079 0.036 0.014 0.024 0.023 0.000 0.000 0.011 0.434 0.081 0.029 0.013 0.035 0.147 0.111 0.002 0.000 0.000 0.040 0.010 0.043 0.077 0.014 0.015 0.021 0.638 0.007 0.005 0.020 0.027 0.029 0.065 0.000 0.000 0.000 0.021 0.000 0.000 0.034 0.007 0.012 0.072 0.299 0.000 0.000 0.014 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.034 0.048 0.000 0.000 0.000 0.021 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.021 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 224.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.123 0.046 0.058 0.102 0.258 0.226 0.041 0.014 0.079 0.104 0.024 0.067 0.134 0.021 0.028 0.138 1.462 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 2067.000 131.030 564.400 30.220 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-69
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F (1.5 < AT
- 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.000 0.006 0.000 0.000 0.000 0.005 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.031 0.219 0.024 0.020 0.034 0.102 0.022 0.005 0.002 0.000 0.027 0.003 0.000 0.001 0.000 0.000 0.029 0.488 0.142 0.048 0.009 0.017 0.057 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.033 0.313 0.009 0.000 0.024 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.033 0.066 0.000 0.000 0.000 0.000 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 12.5-18.4 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 224.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.370 0.072 0.109 0.052 0.172 0.030 0.005 0.002 0.005 0.027 0.003 0.009 0.001 0.000 0.000 0.096 0.953 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 2067.000 131.030 333.640 19.690 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-70
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (AT > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.008 0.004 0.003 0.013 0.000 0.000 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.033 0.104 0.024 0.009 0.030 0.036 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.003 0.000 0.049 0.254 0.046 0.014 0.007 0.000 0.013 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.014 0.101 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.158 0.042 0.019 0.042 0.049 0.007
- 0. 002 0.000 0.000 0.000 0.000 0.000 0.000 0.003 0.000 0.066 0.389 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 2067.000 131.030 116.390 8.040 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-71
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (AT * -1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.470 0.139 0.000 0.000 0.045 0.000 0.000 0.000 0.000 0.792 0.000 0.041 0.000 0.000 0.000 0.043 0.373 0.345 0.171 0.000 0.000 0.088 0.000 0.000 0.000 0.000 1.061 0.320 0.000 0.000 0.000 0.000 0.000 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.359 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 224.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL
- 0. 320 0.041 0.000 0.000 0.000 0.043 0.550 0.816 0.311 0.000 0.000 0.133 0.000 0.000 0.000 0.000 2.212 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 2067.000 1935.970 67.780 45.720 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-72
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9 < AT * -1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.097 0.242 0.000 0.000 0.000 0.097 0.000 0.000 0.000 0.000 0.435 0.047 0.091 0.048 0.000 0.000 0.000 0.469 0.046 0.186 0.045 0.047 0.095 0.045 0.000 0.000 0.000 1.121 0.128 0.126 0.045 0.000 0.000 0.000 0.296 0.043 0.088 0.043 0.000 0.000 0.041 0.042 0.041 0.045 0.937 0.080 0.000 0.000 0.000 0.000 0.000 0.161 0.000 0.000 0.000 0.040 0.000 0.000 0.000 0.039 0.000 0.320 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.256 0.218 0.092 0.000 0.000 0.000 1.023 0.331 0.274 0.089 0.087 0.192 0.087 0.042 0.080 0.045 2.814 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 2067.000 1935.970 63.930 58.170 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-73
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7 < AT * -1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.097 0.048 0.000 0.000 0.000 0.000 0.000 0.290 0.435 0.242 0.242 0.145 0.242 0.000 0.048 0.000 0.000 1.693 0.000 0.045 0.000 0.000 0.000 0.000 0.327 0.046 0.140 0.094 0.090 0.048 0.048 0.000 0.046 0.000 0.886 0.253 0.125 0.086 0.000 0.000 0.171 0.298 0.130 0.043 0.000 0.000 0.044 0.303 0.215 0.000 0.129 1.795 0.040 0.000 0.000 0.000 0.000 0.000 0.160 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.077 0.234 0.549 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.030 0.030
Ž24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.342 0.170 0.086 0.000 0.000 0.171 1.075 0.659 0.473 0.336 0.236 0.334 0.351 0.302 0.123 0.393 5.051 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 2067.000 1935.970 112.740 104.400 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-74
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5 < AT * -0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.145 0.097 0.145 0.242 0.048 0.145 0.339 1.161 0.919 0.774 0.822 0.532 0.242 0.048 0.000 0.000 18.5-24.4 0.339 0.290 0.242 0.097 0.290 0.290 0.871 1.209 1.306 1.161 0.919 1.064 1.306 0.435 0.532 0.387 0.556 0.373 0.093 0.045 0.092 0.141 0.793 0.278 0.604 0.328 0.428 0.472 1.296 0.659 0.651 0.277 7.088 0.719 0.595 0.380 0.086 0.170 0.811 1.267 0.427 0.645 0.342 0.175 0.216 0.911 0.892 0.783 0.842 9.261 0.314 0.275 0.000 0.000 0.039 0.000 0.787 0.468 0.078 0.117 0.000 0.000 0.040 0.118 0.276 0.904 3.417 0.139 0.188 0.000 0.000 0.000 0.000 0.139 0.115 0.063 0.114 0.000 0.000 0.000 0.000 0.000 0.338 1.096
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 2.213 1.818 0.860 0.470 0.640 1.388 4.196 3.658 3.616 2.884 2.344 2.284 3.796
- 2. 153 2.241 2.748 SUBTOTAL 0.000 5.660 10.740 0.000 37.310 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2067.000 1935.970 808.120 771.200 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-75
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5 < AT
- 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000
'0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 00.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.290 0.145 0.484 0.000 0.242 0.145 0.387 0.242 0.387 0.484 0.290 0.242 0.290 0.097 0.097 0.097 3.919 0.290 0.387 0.194 0.290 0.242 0.581 0.290 0.726 0.919 0.435 0.774 0.484 0.919 0.435 0.097 0.435 7.499 0.374 0.187 0.184 0.189 0.274 0.604 0.420 0.325 0.744 0.280 0.095 0.236 1.061 0.372 0.282 0.048 5.674 0.893 0.516 0.259 0.306 0.473
- 0. 903 0.718 0.567 0.473 0.214 0.086 0.174 0.916 0.216 0.132 0.506 7.351 0.079 0.000 0.000 0.000 0.000 0.040 0.358 0.078 0.196 0.119 0.000 0.000 0.039 0.000 0.000 0.358 1.268 18.5-24.4 0.000 0.000 0.000 0.028 0.000 0.000 0.000 0.000 0.057 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.085
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.975 1.236 1.120 0.813 1.231 2.272 2.173 1.938 2.776 1.532 1.245 1.135 3.226 1.120 0.607 1.445 0.000 25.843 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 2067.000 1935.970 564.400 534.180 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-76
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F (1.5 < AT
- 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.048 0.048 0.000 0.000 0.000 0.000 0.000 0.145 0.000 0.145 0.145 0.194 0.000 0.145 0.145 0.290 0.339 0.339 0.194 0.097 0.242 0.242 0.097 0.000 2.612 0.145 0.194 0.290 0.339 0.242 0.484 0.339 0.339 0.194 0.048 0.339 0.387 0.097 0.242 0.048 0.194 3.919 0.370 0.280 0.507 0.280 0.324 0.421 0.377 0.232 0.000 0.000 0.048 0.045 0.094 0.048 0.047 0.139 3.211 1.059 1.233 0.170 0.087 0.306 0.563 0.431 0.217 0.087 0.000 0.000 0.000 0.043 0.000 0.000 0.504 4.698 0.321 0.120 0.040 0.040 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.080 0.601 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 224. 5 0.000 0.000 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.895 1.971 1.155 0.939 0.872 1.612 1.340 1.077 0.619 0.435 0.628 0.529 0.476 0.532 0.192 0.916 0.002 15.189 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F
2067.000 1935.970 333.640 313.950 METEOROLOGICAL FACILITY:
-BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-77
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (AT > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.048 0.000 0.048 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.242 0.000 0.000 0.000 0.048 0.097 0.048 0.145 0.194 0.290 0.097 0.145 0.097 0.097 0.097 0.000 0.048 1.403 0.000 0.000 0.048 0.048 0.000 0.097 0.194 0.290 0.097 0.145 0.048 0.000 0.048 0.048 0.000 0.000 1.064 0.047 0.188 0.472 0.184 0.000 0.093 0.325 0.047 0.048 0.000 0.000 0.000 0.000 0.000 0.094 0.000 1.499 0.000 0.262 0.431 0.172 0.085 0.000 0.044 0.000 0.000 0.000 0A000 0.000 0.000 0.000 0.000 0.000 0.993 0.000 0.040 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.040 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.047 0.538 1.000 0.452 0.230 0.238 0.708 0.531 0.484 0.242 0.194 0.097 0.145 0.194 0.094 0.048 5.242 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 2067.000 1935.970 116.390 108.350 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-78
BROWNS FERRY NUCLEAR PLANT 2011 METEOROLOGICAL DATA TABLE 8 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL RELEASE MODE AND ELEVATED RELEASE MODE)
FOURTH QUARTER E2-79
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (AT
- -1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
- 0. 022 0.087 0.000 0.012 0.000 0.000 0.000 0.000 0.000 0.000 0.122 0.000 0.000 0.000 0.000 0.000 0.016 0.090 0.071 0.075 0.076 0.000 0.011 0.000 0.000 0.000 0.000 0.340 0.005 0.000 0.000 0.000 0.005 0.040 0.024 0.000 0.000 0.000 0.000 0.006 0.000 0.000 0.000 0.000 0.080 0.028 0.023 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.031 0.006 0.000 0.056 0.144 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 224.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.032 0.023 0.000 0.000 0.005 0.056 0.136 0.158 0.075 0.088 0.000 0.018 0.031 0.006 0.000 0.056 0.686 TOTAL HOURS OF VALID OBSERVATIONS TOTAL TOTAL TOTAL HOURS HOURS HOURS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2194.000 292.070 26.670 15.050 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-80
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9 < AT * -1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.014 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.021 0.000 0.000 0.000 0.000 0.000 0.017 0.006 0.010 0.024 0.000 0.000 0.005 0.005 0.000 0.000 0.000 0.067 0.006 0.000 0.000 0.000 0.000 0.007 0.015 0.000 0.000 0.017 0.000 0.000 0.000 0.004 0.000 0.000 0.050 0.043 0.009 0.000 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.030 0.008 0.000 0.005 0.104 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.019 0.000 0.000 0.019 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.049 0.009 0.000 0.000 0.000 0.034 0.022 0.016 0.037 0.017 0.000 0.005 0.035 0.031 0.000 0.005 0.260 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 2194.000 292.070 33.690 5.700 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-81
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7 < AT * -1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.000 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.000 0.000 0.000 0.000 0.004 0.012 0.021 0.003 0.004 0.000 0.000 0.003 0.000 0.000 0.000 0.000 0.047 0.008 0.004 0.005 0.000 0.007 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.006 0.004 0.004 0.051 0.021 0.006 0.000 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.031 0.060 0.033 0.035 0.193 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.009 0.018 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.029 0.010 0.005 0.006 0.011 0.026 0.021 0.005 0.004 0.000 0.000 0.003 0.038 0.075 0.037 0.047 0.318 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 2194.000 292.070 62.570 6.980 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-82
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5 < AT * -0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.031 0.021 0.070 0.077 0.022 0.000 0.003 0.000 0.000 0.000 0.000 0.225 0.018 0.019 0.000 0.003 0.008 0.044 0.076 0.109 0.108 0.067 0.048 0.027 0.026 0.000 0.000 0.010 0.563 0.123 0.107 0.010 0.001 0.015 0.027 0.036 0.000 0.127 0.017 0.015 0.037 0.106 0.020 0.070 0.134 0.845 0.189 0.116 0.048 0.000 0.000 0.008 0.000 0.013 0.036 0.186 0.009 0.026 0.317 0.126 0.327 0.321 1.721 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.056 0.219 0.334 0.018 0.627 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.032 0.000 0.000 0.032
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.330 0.242 0.057 0.004 0.024 0.110 0.133 0.193 0.347 0.292 0.072 0.093 0.504 0.397 0.732 0.484 4.013 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 2194.000 292.070 811.150 88.050 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-83
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5 < AT
- 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.003 0.000 0.000 0.000 0.000 0.005 0.000 0.000 0.000 0.000 0.008 0.010 0.007 0.000 0.018 0.056 0.088 0.164 0.316 0.217 0.036 0.008 0.022 0.009 0.005 0.000 0.002 0.958 0.061 0.019 0.015 0.036 0.092 0.125 0.278 0.243 0.685 0.076 0.022 0.032 0.087 0.017 0.029 0.028 1.846 0.038 0.015 0.006 0.000 0.000 0.088 0.181 0.000 0.454 0.052 0.000 0.000 0.041 0.015 0.053 0.052 0.995 0.018 0.031 0.000 0.000 0.000 0.018 0.000 0.000 0.038 0.040 0.000 0.000 0.024 0.028 0.063 0.049 0.309 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.028 0.010 0.038 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.126 0.071 0.021 0.055 0.148 0.320
- 0. 627 0.560 1.393 0.204 0.030 0.059 0.161 0.066 0.173 0.141 4.154 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 2194.000 292.070 674.840 91.130 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-84
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F (1.5 < AT
- 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.011 0.000 0.000 0.021 0.007 0.014 0.034 0.030 0.008 0.000 0.006 0.000 0.000 0.000 0.000 0.000 0.132 0.069 0.015 0.025 0.059 0.152 0.152 0.070 0.337
- 0. 392 0.018 0.005 0.000 0.000 0.000 0.014 0.021 1.329 0.064 0.078 0.045 0.062 0.107 0.026 0.012 0.077 0.552 0.015 0.000 0.000 0.000 0.003
- 0. 010 0.039 1.091 0.008 0.008 0.000 0.008 0.000 0.000 0.000 0.000 0.113 0.000 0.000 0.000 0.000 0.000 0.000 0.031 0.167 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.152 0.109 0.070 0.150 0.266 0.193 0.116 0.444 1.064 0.033 0.012 0.000 0.000 0.004 0.024 0.091 2.728 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 2194.000 292.070 384.990 59.860 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-85
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (AT > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT GROUND LEVEL RELEASE MODE OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 12.5-18.4 18.5-24.4 0.001 0.000 0.000 0.001 0.000 0.000 0.000 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.010 0.001 0.021 0.041 0.013 0.000 0.024 0.057 0.017 0.009 0.000 0.000 0.000 0.000 0.005 0.016 0.214 0.142 0.022 0.026 0.082 0.060 0.022 0.025 0.179 0.176 0.000 0.000 0.000 0.000 0.000 0.001 0.034 0.768 0.086 0.026 0.019 0.011 0.000 0.000 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.157 0.000 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 224.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.239 0.057 0.066 0.134 0.074 0.022 0.049 0.238 0.203 0.009 0.000 0.000 0.000 0.000 0.006 0.057 1.153 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 2194.000 292.070 200.090 25.300 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-86
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (AT * -1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.044 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.044 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.116 0.000 0.000 0.081 0.000 0.000 0.000 0.000 0.000 0.196 0.000 0.000 0.000 0.000 0.000 0.000 0.037 0.188 0.000 0.000 0.000 0.000 0.037 0.000 0.000 0.000 0.263 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.026 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.026
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.082 0.330 0.000 0.000 0.081 0.000 0.037 0.000 0.000 0.000 0.530 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 2194.000 1901.930 26.670 11.620 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-87
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9 < AT * -1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.088 0.043 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.131 0.041 0.078 0.039 0.000 0.000 0.040 0.119 0.077 0.000 0.038 0.040 0.000 0.039 0.000 0.000 0.000 0.510 0.186 0.000 0.000 0.000 0.000 0.000 0.149 0.037 0.074 0.037 0.038 0.000 0.075 0.000 0.000 0.037 0.634 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.227 0.078 0.039 0.000 0.000 0.040 0.356 0.158 0.074 0.076 0.077 0.000 0.113 0.000 0.000 0.037 1.276 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 2194.000 1901.930 33.690 27.990 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-88
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7 < AT * -1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.091 0.091 0.000 0.000 0.000 0.000 0.273 0.000 0.000 0.000 0.000 0.000 0.000 0.129 0.043 0.000 0.044 0.045 0.088 0.046 0.000 0.000 0.000 0.393 0.158 0.000 0.000 0.000 0.000 0.041 0.482 0.040 0.000 0.118 0.040 0.164 0.077 0.040 0.000 0.080 1.239 0.186 0.074 0.000 0.000 0.000 0.038 0.110 0.112 0.038 0.000 0.000 0.000 0.000 0.037 0.000 0.000 0.596 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.032 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.032
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.345 0.074 0.000 0.000 0.000 0.079 0.767 0.273 0.038 0.161 0.175 0.343 0.122 0.077 0.000 0.080 2.534 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 2194.000 1901.930 62.570 55.590 METEOROLOGICAL FACILITY-BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-89
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5 < AT -< -0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 01.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.091 0.046 0.046 0.091 0.046 0.091 0.182 0.547 0.182 0.273 0.273 0.091 0.046 0.137 0.091 0.137 0.000 2.279 0.046 0.091 0.182 0.046 0.182 0.319 0.866 0.410 0.365 0.091 0.137 0.182 0.228 0.365 0.365 0.273 4.148 0.218 0.303 0.172 0.087 0.000 0.264 0.663 0.134 0.220 0.000 0.132 0.176 0.394 0.434 0.435 0.526 1.340
- 1. 680 0.677 0.000 0.039 0.199 1.392 0.281 0.282 0.476 0.762 0.476 1.264 1.082 1.028 2.156 0.931 0.410 0.000 0.000 0.000 0.187 0.224 0.403 0.369 0.597 0.222 0.148 1.154 0.658 1.398 0.706 7.406 18.5-24.4 0.088 0.030 0.000 0.000 0.000 0.000 0.369 0.203 0.106 0.061 0.000 0.000 0.060 0.245 0.462 0.035
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.021 0.025 0.009 0.026 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 2.669 2.559 1.123 0.178 0.313 1.152 4.082 1.639 1.624 1.525 1.344 1.028 3.237 2.920 3.825 3.743 SUBTOTAL 4.160 13.136 1.658 0.081 32.958 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2194.000 1901.930 811.150 723.100 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-90
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5 < AT
- 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND DIRECTION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 N
NNE NE ENE E.
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24. 5 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.046 0.091 0.000 0.091 0.182 0.228 0.046 0.137 0.091 0.046 0.046 0.182 0.000 0.091 0.046 1.367 0.091 0.228 0.091 0.137 0.137 0.091 0.273 0.091 0.273 0.091 0.228 0.046 0.182 0.273 0.182 0.182 2.598 0.262 0.088 0.307 0.262 0.175 0.304 0.352 0.355 0.438 0.133 0.262 0.088 0.700 0.216 0.131 0.308 0.196 0.360 0.362 0.247 0.447 1.083 1.398 0.758 1.395 1.107 0.358 0.369 0.483 0.562 0.834 0.806 0.074 0.149 0.076 0.000 0.000 0.149 0.483 1.033 1.814 1.301 0.113 0.000 0.075 0.000 0.073 0.260 5.602 0.000 0.000 0.000 0.000 0.000 0.000 0.146 0.758 0.579 0.165 0.000 0.000 0.000 0.000 0.036 0.000 1.684 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.072 0.066 0.025 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.670 0.871 0.927 0.646 0.849 1.856 2.880 3.113 4.702 2.912 1.006 0.547 1.623 1.052 1.348 1.602 SUBTOTAL 4.380 10.766 0.163 26.605 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 2194.000 1901.930 674.840 583.710 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-91
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F (1.5 < AT
- 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.091 0.046 0.046 0.137 0.091 0.182 0.137 0.137 0.091 0.000 0.137 0.046 0.000 1.231 0.091 0.046 0.046 0.091 0.000 0.228 0.046 0.000 0.182 0.410 0.046 0.000 0.182 0.228 0.137 0.091 1.823 0.043 0.131 0.219 0.223 0.044 0.170 0.387 0.220 0.220 0.268 0.000 0.087 0.132 0.046 0.176 0.086 2.451 0.598 0.719 0.318 0.315 0.599 1.150 1.490 0.354 1.072 0.434 0.039 0.000 0.000 0.000 0.121 0.202 7.412 0.000 0.075 0.000 0.000 0.037 0.000 0.000 0.851 0.626 0.113 0.000 0.000 0.000 0.000 0.000 0.000 1.702 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.201 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.201
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.732 0.970 0.673 0.721 0.726 1.594 2.060 1.717 2.282 1.362 0.222 0.178 0.314 0.410 0.479 0.380 0.000 14.819 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 2194.000 1901.930 384.990 325.130 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-92
SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (AT > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT ELEVATED RELEASE MODE OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.046 0.000 0.046 0.046 0.046 0.000 0.000 0.046 0.319 0.046 0.046 0.091 0.000 0.182 0.046 0.182 0.228 0.228 0.273 0.091 0.137 0.046 0.182 0.137 0.091 2.005 0.091 0.137 0.182 0.000 0.228 0.182 0.593 0.137 0.046 0.046 0.000 0.000 0.000 0.091 0.137 0.137 2.005 0.086 0.000 0.218 0.259 0.175 0.128 0.445 0.087 0.000 0.042 0.000 0.000 0.045 0.000 0.043 0.088 1.616 0.469 0.159 0.200 0.082 0.082 0.245 0.243 0.079 0.157 0.119 0.000 0.000 0.000 0.000 0.000 0.000 1.835 0.038 0.038 0.037 0.000 0.000 0.000 0.000 0.073 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.186 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.730 0.379 0.728 0.341 0.667 0.646 1.464 0.649 0.476 0.480 0.137 0.182 0.136 0.273 0.316 0.361 7.967 HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 2194.000 1901.930 200.090 174.790 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-93
BROWNS FERRY NUCLEAR PLANT 2011 METEOROLOGICAL DATA TABLE 9 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES FIRST QUARTER E2-94
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (AT * -1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.o00o 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.139 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.186 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000, 0.000 0.046 0.046 0.139 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.278 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2156 6
6 2156 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 8.28 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-95
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9 < AT * -1.7 C/100M)
BROWNS FERRY NUCLEAR PLANT JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.139 0.046 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.278 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2156 6
6 2156 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 9.78 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-96
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7 < AT * -1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.093 0.046 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.186 0.093 0.046 0.000 0.000 0.000 0.139 0.046 0.093 0.000 0.000 0.000 0.139 0.000 0.000 0.000 0.000 0.557 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.093 0.000 0.046 0.000 0.046 0.139 0.139 0.510 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 224.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.093 0.046 0.000 0.000 0.000 0.325 0.093 0.139 0.000 0.139 0.046 0.186 0.000 0.046 0.139 0.139 1.391 TOTAL HOURS OF VALID STABILITY TOTAL HOURS OF STABILITY CLASS OBSERVATIONS C
TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2156 30 30 2156 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 11.31 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-97
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5 < AT < -0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JANUARY 1, 2011 -
MARCH 31, 2011 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>-24.5 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.046 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.232 0.093 0.046 0.000 0.093 0.093 0.000 0.139 0.186 0.093 0.093 0.139 0.000 0.000 0.046 0.000 0.046 1.067 0.139 0.139 0.186 0.139 0.232 0.510 0.139 0.093 0.186 0.093 0.139 0.186 0.232 0.371 0.278 0.186 3.247 0.325 0.603 0.278 0.696 0.649 0.464 0.046 0.093 0.278 0.139 0.325 0.371 0.603 0.232 0.417 0.371 1.252 2.087 1.577 1.252 0.835 0.742 0.278 0.278 0.093 0.371 0.788 1.020 0.974 1.391 1.438 1.577 1.531 0.881 0.696 0.417 0.325 0.464 0.371 0.232 0.186 0.278 0.557 0.649 0.881 1.531 2.551 2.365 0.371 0.000 0.000 0.000 0.000 0.278 0.186 0.093 0.000 0.000 0.139 0.278 0.788 1.438 0.928 0.649 5.148 0.000 0.000 0.000 0.000 0.000 0.232 0.835 0.139 0.000 0.000 0.000 0.000 0.232 0.325 0.139 0.046 TOTAL 3.711 3.757 2.737 2.597 2.226 2.690 2.041 1.113 0.881 0.974 2.134 2.505 3.711 5.334 5.751 5.241 SUBTOTAL 5.891 15.955 13.915 1.948 47.403 TOTAL HOURS OF VALID STABILITY TOTAL HOURS OF STABILITY CLASS OBSERVATIONS D
TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2156 1022 1022 2156 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 12.34 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-98
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5 < AT
- 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 N
NNE NE ENE E
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 0.046 0.000 0.139 0.232 0.139 0.093 0.139 0.046 0.046 0.000 0.000 0.000 0.000 0.928 0.046 0.000 0.093 0.046 0.232 0.139 0.046 0.093 0.046 0.186 0.000 0.093 0.186 0.000 0.232 0.046 1.484 0.093 0.093 0.000 0.093 0.046 0.325 0.000 0.325 0.278 0.278 0.464 0.046 0.046 0.139 0.046 0.093 0.788 0.742 1.299 0.649 0.325 0.557 0.696 0.928
- 0. 928 1.160 1.020 0.742 0.603 0.232 0.139 0.139 0.464 1.113 0.464 0.371 0.278 0.278 2.134 0.881 1.252 1.113 0.742 0.881 0.510 0.139 0.649 0.557 0.000 0.046 0.186 0.000 0.000 0.139 0.510
- 0. 649 0.788 1.206 0.371 0.093 0.000 0.139 0.093 0.046 4.267 224.5 0.000 0.000 0.000 0.000 0.000 0.046 1.067 0.325 0.464 0.278 0.093 0.000 0.046 0.000 0.000 0.000 TOTAL 1.391 1.994 2.087 1.206 0.881 1.670 4.685 3.340 3.850 4.360 2.737 1.902 1.391 0.649 1.160 0.881 SUBTOTAL 2.365 10.946 11.827 2.319 34.184 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2156 737 737 2156 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 13.86 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-99
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F (1.5 < AT
- 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 N
NNE NE ENE E
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.046 0.046 0.000 0.046 0.046 0.046 0.000 0.046 0.000 0.000 0.000 0.046 0.093 0.417 0.046 0.000 0.046 0.000 0.000 0.046 0.046 0.046 0.000 0.046 0.186 0.093 0.046 0.093 0.046 0.000 0.742 0.000 0.046 0.000 0.046 0.000 0.093 0.000 0.139 0.000 0.186 0.139 0.093 0.000 0.046 0.186 0.046 0.139 0.186 0.139 0.046 0.325 0.371 0.557 0.557 0.649 0.510 0.835 0.371 0.000 0.046 0.093 0.000 0.186 0.278 0.000 0.093 0.232 0.186 0.510 0.557 1.716 0.510 0.186 0.139 0.046 0.000 0.000 0.139 4.777 0.046 0.046 0.000 0.046 0.046 0.000 0.093 0.325 0.417 0.093 0.000 0.000 0.000 0.000 0.000 0.046 1.160
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.417 0.557 0.186 0.278 0.696 0.696 1.345 1.670 2.922 1.345 1.391 0.742 0.093 0.186 0.371 0.325 SUBTOTAL 1.020 4.824 0.186 13.219 TOTAL HOURS OF VALID STABILITY TOTAL HOURS OF STABILITY CLASS OBSERVATIONS F
TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2156 285 285 2156 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 12.20 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-1 00
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (AT > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT JANUARY 1, 2011 -
MARCH 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.093 0.000 0.046 0.046 0.000 0.000 0.046 0.000 0.046 0.046 0.093 0.046 0.093 0.000 0.046 0.000 0.000 0.510 0.000 0.000 0.093 0.000 0.000 0.093 0.000 0.000 0.000 0.093 0.000 0.000 0.000 0.093 0.000 0.000 0.371 0.046 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.046 0.046 0.000 0.046 0.046 0.046 0.046 0.046 0.464 0.000 0.000 0.093 0.093 0.046 0.000 0.000 0.000 0.000 0.093 0.232 0.093 0.000 0.000 0.000 0.000 0.649 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.278 0.139 0.278 0.046 0.093 0.000 0.000 0.000 0.000 0.881 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.139 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.278
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.046 0.093 0.232 0.186 0.046 0.186 0.046 0.371 0.371 0.649 0.371 0.325 0.046 0.186 0.046 0.046 3.247 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2156 70 70 2156 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 9.62 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-101
BROWNS FERRY NUCLEAR PLANT 2011 METEOROLOGICAL DATA TABLE 10 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES SECOND QUARTER E2-102
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (AT
! -1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.144 0.000 0.000 0.144 0.048 0.000 0.000 0.000 0.000 0.383 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.048 0.048 0.000 0.000 0.000 0.000 0.144 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.048 0.000 0.000 0.000 0.000 0.000 0.096
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.192 0.000 0.096 0.239 0.096 0.000 0.000 0.000 0.000 0.670 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2166 14 14 2088 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 11.46 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-103
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9 < AT * -1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.096 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.096 0.192 0.000 0.048 0.000 0.000 0.048 0.000 0.000 0.431 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.287 0.048 0.000 0.000 0.000 0.000 0.431 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.096 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.096
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.048 0.000 0.000 0.000 0.000 0.096 0.000 0.096 0.335 0.096 0.335 0.048 0.000 0.048 0.000 0.000 1.102 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2166 26 23 2088 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 12.21 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-104
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7 < AT * -1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.096 0.048 0.096 0.048 0.000 0.000 0.000 0.335 0.000 0.096 0.000 0.000 0.000 0.048 0.192 0.048 0.000 0.096 0.144 0.000 0.096 0.144 0.048 0.000 0.910 0.192 0.383 0.048 0.000 0.000 0.000 0.096 0.000 0.096 0.096 0.096 0.144 0.287 0.144 0.144 0.192 1.916 0.144 0.000 0.000 0.000 0.000 0.000 0.048 0.048 0.144 0.239 0.287 0.239 0.144 0.192 0.048 0.192 1.724 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.096 0.000 0.000 0.192 0.144 0.000 0.000 0.000 0.479
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 TOTAL 0.335 0.479 0.048 0.000 0.000 0.048 0.383 0.144 0.383 0.527 0.575 0.670 0.718 0.479 0.239 0.383 5.412 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2166 118 113 2088 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 11.85 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-105
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5 < AT * -0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 N
NNE NE ENE E
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.048 0.000 0.000 0.000 0.144 12.5-18.4 18.5-24.4 0.000 0.096 0.048 0.096 0.144 0.096 0.048 0.383 0.287 0.287 0.144 0.431 0.287 0.048 0.144 0.048 2.586 0.000 0.192 0.144 0.096 0.000 0.144 0.479 0.479 0.335 0.383 0.479 0.431 0.335 0.287 0.287 0.048 4.119 0.144 0.383 0.192 0.000 0.096 0.096 0.192 0.431 0.383 0.048 0.335 0.335 0.575 0.431 0.479 0.239 1.102 0.623 0.048 0.192 0.048 0.383 0.575 0.862 1.341 1.102 1.485 0.862 0.623 1.149 0.910 1.197 0.383 0.287 0.096 0.048 0.000 0.048 0.144 1.006 1.533 2.059 0.862 0.575 0.862
- 1. 628 1.964
- 0. 958 0.000 0.000 0.048 0.000 0.000 0.144 0.144 0.144 1.485 0.814 0.287 0.096 0.287 0.527 0.431 0.096 4.502
Ž24.5 0.096 0.000 0.000 0.000 0.000 0.000 0.000 0.144 0.096 0.239 0.048 0.048 0.000 0.096 0.287 0.000 TOTAL 1.772 1.580 0.575 0.431 0.287 0.910 1.580 3.448 5.460 4.981 3.640 2.778 3.017 4.167 4.502 2.586 SUBTOTAL 4.358 12.500 12.452 1.054 41.715 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2166 909 871 2088 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 11.78 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-106
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5 < AT
- 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.096 0.000 0.000 0.000 0.000 0.096 0.144 0.144 0.192 0.144 0.000 0.000 0.000 0.096 0.958 0.000 0.000 0.096 0.048 0.000 0.096 0.000 0.096 0.096 0.192 0.287 0.192 0.192 0.048 0.048 0.144 1.533 0.096 0.144 0.192 0.000 0.048 0.096 0.192 0.287 0.144 0.431 0.383 0.192 0.239 0.048 0.000 0.192 2.682 0.766 0.287 0.383 0.048 0.048 0.192 1.102 1.628 1.389 1.149 1.293 0.431 0.479 0.144 0.192 0.192 9.722 0.192 0.144 0.192 0.000 0.192 0.239 0.862 1.149 1.868 2.011 0.718 0.335 0.527 0.144 0.096 0.287 8.956 0.000 0.048 0.000 0.096 0.000 0.048 0.048 0.431 1.916 1.676 0.144 0.048 0.000 0.000 0.048 0.048 4.550
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 1.533 0.287 0.000 0.000 0.000 0.048 0.048 0.000 TOTAL 1.102
- 0. 623
- 0. 958 0.192 0.287
- 0. 670 2.251
- 3. 688 7.088 5.891 3.017 1.341 1.437 0.431 0.431 0.958 1.964 30.364 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2166 654 634 2088 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 13.59 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-107
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F (1.5 < AT
- 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.048 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.144 0.000 0.048 0.000 0.000 0.048 0.048 0.144 0.048 0.048 0.192 0.096 0.096 0.096 0.048 0.048 0.000 0.958 0.048 0.000 0.000 0.048 0.096 0.144 0.096 0.144 0.000 0.000 0.000 0.096 0.048 0.000 0.096 0.000 0.814 0.144 0.048 0.096 0.144 0.000 0.000 0.239 0.383 0.239 0.192 0.000 0.239 0.096 0.048 0.192 0.096 2.155 0.239 0.479 0.479 0.192 0.144 0.144 0.718 1.533 0.766 0.575 0.527 0.192 0.000 0.000 0.144 0.096 6.226 0.335 0.527 0.335 0.144 0.239 0.335 0.287 0.575 1.437 1.293 0.239 0.000 0.048 0.048 0.000 0.096 5.939 0.000 0.000 0.000 0.096 0.000 0.000 0.000 0.192
- 0. 958 0.144 0.000 0.000 0.000 0.000 0.000 0.000 1.389
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.096 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.766 1.102 0.910 0.623 0.575 0.718 1.485 2.874 3.544 2.395 0.862
- 0. 623 0.335 0.144 0.479 0.287 0.096 17.720 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2166 382 370 2088 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 11.38 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-108
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (AT > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT APRIL 1, 2011 -
JUNE 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0'.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.096 0.000 0.000 0.000 0.096 0.048 0.048 0.000 0.000 0.096 0.096 0.000 0.048 0.096 0.048 0.000 0.000 0.575 0.048 0.000 0.000 0.000 0.192 0.192 0.000 0.048 0.000 0.000 0.048 0.048 0.000 0.000 0.000 0.000 0.575 0.096 0.048 0.192 0.048 0.287 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.096 0.383 0.048 0.000 0.000 0.096 0.144 0.144 0.096 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.144 0.144 0.623 0.192 0.527 0.239 0.144 0.192 0.239 0.192 0.048 0.096 0.144 0.048 0.000 0.048 3.017 0.766 1.006 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED=STABILITY CLASS G TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 9.67 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS 2166 63 63 2088 0
E2-109
BROWNS FERRY NUCLEAR PLANT 2011 METEOROLOGICAL DATA TABLE 11 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES THIRD QUARTER E2-110
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (AT * -1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.198 0.297 0.099 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.595 0.000 0.000 0.000 0.000 0.000 0.099 0.248 0.496 0.198 0.000 0.000 0.149 0.000 0.000 0.000 0.000 1.190 0.397 0.050 0.000 0.000 0.000 0.099 0.198 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.744 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.397 0.050 0.000 0.000 0.000 0.198 0.645 0.793 0.297 0.000 0.000 0.149 0.000 0.000 0.000 0.000 2.529 TOTAL HOURS OF VALID STABILITY TOTAL HOURS OF STABILITY CLASS OBSERVATIONS A
TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2091 51 51 2017 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 10.50 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM-UNROUNDED NUMBERS E2-111
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9 < AT * -1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.099 0.149 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.297 0.050 0.050 0.000 0.000 0.000 0.149 0.198 0.149 0.099 0.000 0.000 0.149 0.000 0.000 0.000 0.000 0.843 0.099 0.198 0.050 0.000 0.000 0.149 0.297 0.050 0.099 0.099 0.000 0.000 0.099 0.050 0.000 0.050 1.239 0.149 0.050 0.000 0.000 0.000 0.050 0.248 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.099 0.000 0.645 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.000 0.050
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.297 0.297 0.050 0.000 0.000 0.347 0.843 0.347 0.198 0.099 0.050 0.198 0.149 0.050 0.099 0.050 3.074 TOTAL HOURS OF VALID STABILITY TOTAL HOURS OF STABILITY CLASS OBSERVATIONS B
TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2091 63 62 2017 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 9.21 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-112
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7 < AT * -1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.149 0.099 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.297 0.000 0.000 0.000 0.000 0.000 0.050 0.297 0.198 0.050 0.050 0.198 0.149 0.000 0.050 0.000 0.000 1.041 0.050 0.000 0.000 0.000 0.000 0.198 0.149 0.149 0.149 0.050 0.050 0.198 0.050 0.050 0.000 0.000 1.091 0.149 0.149 0.050 0.000 0.099 0.248 0.198 0.099 0.050 0.050 0.099 0.050 0.248 0.248 0.050 0.198 1.983 0.248 0.000 0.000 0.000 0.000 0.347 0.000 0.050 0.000 0.000 0.000 0.000 0.000 0.099 0.099 0.099 0.942 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.149 0.099 0.248
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.446 0.149 0.050 0.000 0.099 0.843 0.645 0.645 0.347 0.149 0.347 0.446 0.297 0.446 0.297 0.397 5.602 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2091 113 113 2017 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 9.16 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-113
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5 < AT * -0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 N
NNE NE ENE E
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.050 0.050 0.050 0.000 0.000 0.000 0.000 0.198 0.099 0.050 0.248 0.149 0.248 0.050 0.347 0.645 0.793 0.694 0.694 0.694 0.149 0.149 0.050 0.050 5.107 0.149 0.198 0.198 0.050 0.050 0.496 0.843 0.496 0.297 0.892 0.645 1.140 0.992 0.198 0.397 0.347 7.387 0.595 0.297 0.099 0.149 0.050 0.347 0.446 0.149 0.496 0.446 0.446 0.744 0.843 0.744 0.545 0.198 1.239 0.496 0.149 0.099 0.248 0.595 1.091 0.496 1.140 0.446 0.645 0.595 2.082 1.190 0.843 0.793 0.545 0.347 0.248 0.050 0.149 0.744 1.041 0.000 0.198 0.248 0.099 0.000 0.099 0.347 0.198 1.091 5.404 0.347 0.099 0.000 0.000 0.050 0.000 0.843 0.347 0.198 0.149 0.000 0.000 0.000 0.000 0.198 0.744 2.975
Ž24.5 0.099 0.198 0.000 0.000 0.000 0.000 0.000 0.000 0.099 0.000 0.000 0.000 0.000 0.000 0.000 0.099 TOTAL 3.074 1.686 0.942 0.496 0.793 2.231 4.660 2.132 3.223
- 2. 925 2.578 3.223 4.165 2.628 2.231 3.322 SUBTOTAL 6.594 12.147 0.496 40.307 TOTAL HOURS OF VALID STABILITY TOTAL HOURS OF STABILITY CLASS OBSERVATIONS D
TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2091 845 813 2017 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 9.07 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-114
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5 < AT
- 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.050 0.050 0.099 0.099 0.000 0.099 0.099 0.149 0.297 0.000 0.297 0.099 0.050 0.297 0.000 0.198 0.149 1.983 0.248 0.099 0.099 0.099 0.149 0.297 0.297 0.347 0.248 0.446 0.496 0.198 0.347 0.248 0.198 0.099 3.917 0.050 0.397 0.347 0.347 0.14.9 0.248 0.347 0.397 0.744 0.446 0.297 0.198 0.347 0.347 0.397 0.000 5.057 0.645 0.297 0.297 0.397 0.099 0.843 0.992 0.793
- 0. 942 0.545 0.198 0.446 1.934 0.694 0.050 0.297 9.470 0.942 0.496 0.198 0.099 0.347 0.496 0.744 0.248 0.248 0.149 0.099 0.050 0.297 0.149 0.000 0.595 5.156 0.050 0.000 0.000 0.050 0.000 0.000 0.198 0.050 0.248 0.050 0.050 0.000 0.050 0.000 0.000 0.198 0.942
Ž24.5 TOTAL 0.000 1.983 0.000 1.388 0.000 1.041 0.000 0.992 0.000 0.843 0.000 1.983 0.000 2.727 0.000 2.132 0.050 2.479 0.000 1.934 0.000 1.239 0.000 0.992 0.000 3.272 0.000 1.438 0.000 0.843 0.000 1.339 0.050 26.624 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2091 574 537 2017 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 9.18 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-115
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F (1.5 < AT
- 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.050 0.050 0.000 0.099 0.099 0.000 0.099 0.149 0.149 0.099 0.149 0.050 0.149 0.099 0.000 0.099 1.339 0.050 0.099 0.000 0.347 0.000 0.297 0.297 0.248 0.149 0.347 0.248 0.050 0.099 0.198 0.198 0.149 2.776 0.149 0.297 0.149 0.149 0.050 0.149 0.198 0.248 0.050 0.198 0.149 0.149 0.050 0.050 0.099 0.149 2.281 0.297 0.397 0.545 0.595 0.496 0.496 0.793 1.140 0.050 0.000 0.099 0.347 0.198 0.099 0.050 0.149 5.751 0.992 0.892 0.248 0.248 0.050 0.099 0.099 0.149 0.050 0.000 0.000 0.000 0.050 0.000 0.000 0.397 3.272 0.694 0.050 0.000 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.843
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 2.231 1.785 0.942 1.487 0.744 1.041 1.487 1.934 0.446
- 0. 645 0.645 0.595 0.545 0.446 0.347 0.992 0.000 16.311 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2091 333 329 2017 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 9.46 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-116
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (AT > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT JULY 1, 2011 -
SEPTEMBER 30, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
-0. 000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.050 0.000 0.000 0.000 0.050 0.000 0.050 0.198 0.099 0.050 0.099 0.050 0.000 0.000 0.248 0.050 0.000 0.149 0.050 0.000 0.000 0.000 0.050 0.000 0.843 0.050 0.099 0.050 0.050 0.050 0.248 0.000 0.149 0.000 0.050 0.297 0.050 0.050 0.000 0.000 0.000 1.140 0.000 0.050 0.000 0.000 0.198 0.099 0.248 0.198 0.248 0.050 0.099 0.050 0.099 0.000 0.050 0.050 1.438 0.000 0.050 0.198 0.397 0.050 0.099 0.099 0.099 0.198 0.000 0.000 0.000 0.099 0.000 0.050 0.000 1.339 0.000 0.000 0.248 0.248 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.545 0.000 0.050 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.149 0.297 0.595 0.744 0.347 0.446 0.595 0.496 0.496 0.297 0.446 0.099 0.248 0.050 0.149 0.099 5.553 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2091 112 112 2017 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 6.87 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-117
BROWNS FERRY NUCLEAR PLANT 2011 METEOROLOGICAL DATA TABLE 12 JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES FOURTH QUARTER E2-118
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (AT * -1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.0.00 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.137 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.228 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.365 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.091 224.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.228 0.273 0.000 0.046 0.046 0.000 0.046 0.000 0.000 0.000 0.638 TOTAL HOURS OF VALID STABILITY TOTAL HOURS OF STABILITY CLASS OBSERVATIONS A
TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2194 14 14 2194 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 14.64 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-119
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B (-1.9 < AT * -1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7-.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.091 0.000 0.046 0.000 0.000 0.046 0.137 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.365 0.137 0.000 0.000 0.000 0.000 0.046 0.273 0.091 0.046 0.046 0.000 0.000 0.137 0.000 0.000 0.182 0.957 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.137
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0./0.00 0.000 0.000 0.000 0.000 TOTAL 0.228 0.000 0.046 0.000 0.000 0.137 0.456 0.091 0.046 0.137 0.046 0.000 0.137 0.000 0.000 0.182 1.504 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2194 33 33 2194 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 14.36 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-120
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C (-1.7 < AT * -1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND
'DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
'0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.137 0.000 0.000 0.000 0.000 0.182 0.046 0.000 0.000 0.000 0.456 0.137 0.000 0.000 0.000 0.000 0.365 0.137 0.046 0.046 0.091 0.182 0.091 0.000 0.046 0.000 0.091 1.231 0.319 0.000 0.000 0.000 0.000 0.137 0.091 0.137 0.000 0.091 0.000 0.046 0.137 0.000 0.000 0.000 0.957 0.000 0.046 0.000 0.000 0.000 0.091 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.228
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.456 0.046 0.000 0.000 0.000 0.684 0.365 0.273 0.046 0.182 0.182 0.319 0.182 0.046 0.000 0.091 2.871 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2194 63 63 2194 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 12.15 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-121
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D (-1.5 < AT < -0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.137 0.000 0.046 0.046 0.046 0.091 0.182 0.137 0.046 0.137 0.046 0.228 0.000 0.182 0.137 0.000 0.091 1.413 0.000 0.000 0.273 0.000 0.091 0.866 0.456 0.319 0.137 0.000 0.228 0.137 0.273 0.547 0.273 0.091 3.692 0.273 0.182 0.091 0.182 0.137 0.273 0.319 0.228 0.091 0.091 0.000 0.091 0.182 0.410 0.319 0.273 1.048 1.139 0.547 0.091 0.091 0.775 0.684 0.273 0.410 0.410
- 0. 638 0.410 0.775 1.367 0.638 2.005 1.823 0.866 0.273 0.000 0.000 0.638 0.775 0.319 0.410 0.820 0.319 0.501 1.413 0.547 1.732 1.048 0.410 0.091 0.000 0.000 0.000 0.137 0.684 0.365 0.273 0.182 0.137 0.091 1.003 0.957 1.139 0.228 5.697
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.365 0.365 0.137 0.228 0.000 0.000 0.182 0.182 0.000 0.000 TOTAL 3.555 2.370 1.231 0.319 0.410 2.871 3.418 1.960 1.595 1.778 1.550 1.231 4.011 4.148 4.148 3.737 SUBTOTAL 3.145 11.304 11.486 1.459 38.332 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2194 841 841 2194 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 12.67 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-122
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E (-0.5 < AT
-< 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.137 0.046 0.046 0.091 0.046 0.137 0.000 0.046 0.000 0.273 0.046 0.000 0.000 0.046 0.000 0.000 0.046 0.820 0.091 0.000 0.091 0.091 0.091 0.137 0.046 0.046 0.046 0.000 0.000 0.046 0.182 0.000 0.091 0.000 0.957 0.137 0.046 0.091 0.137 0.137 0.137 0.273 0.182 0.182 0.000 0.137 0.000 0.137 0.273 0.182 0.000 2.051 0.365 0.410 0.501 0.137 0.319 0.456 0.593 0.820 1.413 0.729 0.593 0.273 0.820 0.638 0.410 0.501 0.319 0.228 0.273 0.046 0.319 1.139 1.185 1.367 2.644 1.459 0.365 0.365 0.273 0.501 0.501 0.912 0.046 0.182 0.000 0.000 0.000 0.228 0.866 0.912 1.459 0.638 0.000 0.000 0.046 0.000 0.137 0.046 4.558
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.046 0.456 1.459 0.365 0.091 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.003 0.912 1.094 0.501 1.003 2.142 3.464 4.786 6.381 2.963 1.094 0.684 1.504 1.413 1.367 1.504 8.979 11.896 2.416 31.814 TOTAL HOURS OF VALID STABILITY TOTAL HOURS OF STABILITY CLASS OBSERVATIONS E
TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2194 698 698 2194 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 14.23 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-123
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F (1.5 < AT
- 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.137 0.000 0.000 0.046 0.000 0.137 0.046 0.137 0.046 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.046 0.547 0.000 0.000 0.000 0.046 0.137 0.046 0.182 0.046 0.000 0.091 0.000 0.000 0.046 0.182 0.182 0.000 0.957 0.000 0.000 0.091 0.046 0.046 0.000 0.046 0.046 0.000 0.046 0.182 0.000 0.000 0.273 0.091 0.000 0.866 0.182 0.182 0.273 0.273 0.319 0.365 0.638 0.410 0.365 0.365 0.319 0.000 0.000 0.046 0.273 0.182 4.193 0.501 0.729 0.273 0.182 0.365 0.866 1.048 1.641 1.185 0.638 0.046 0.091 0.000 0.000 0.091 0.182 7.840 0.091 0.091 0.046 0.000 0.091 0.228 0.182 0.729 0.182 0.228 0.000 0.000 0.000 0.000 0.000 0.000 1.869
Ž24.5 TOTAL 0.000 0.775 0.000 1.003 0.000 0.729 0.000 0.593 0.000 1.139 0.000 1.550 0.091 2.325 0.000 2.917 0.000 1.732 0.000 1.367 0.000 0.638 0.000 0.091 0.000 0.046 0.000 0.501 0.000 0.638 0.000 0.456 0.091 16.500 TOTAL HOURS OF VALID STABILITY TOTAL HOURS OF STABILITY CLASS OBSERVATIONS F
TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2194 362 362 2194 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 13.03 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-124
JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (AT > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCTOBER 1, 2011 -
DECEMBER 31, 2011 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 12.5-18.4 18.5-24.4 0.046 0.000 0.000 0.046 0.000 0.091 0.000 0.000 0.000 0.046 0.000 0.091 0.000 0.000 0.000 0.000 0.319 0.000 0.046 0.000 0.365 0.137 0.228 0.046 0.137 0:137 0.091 0.046 0.091 0.000 0.000 0.046 0.091 1.459 0.000 0.000 0.046 0.046 0.091 0.228 0.228 0.137 0.091 0.091 0.091 0.000 0.046 0.046 0.046 0.046 1.231 0.046 0.000 0.000 0.046 0.273 0.228 0.228 0.319 0.046 0.000 0.182 0.000 0.000 0.046 0.046 0.000 1.459 0.228 0.046 0.273 0.182 0.182 0.091 0.228 0.137 0.091 0.137 0.000 0.000 0.000 0.046 0.137 0.137 1.914 0.456 0.182 0.137 0.000 0.046 0.091 0.182 0.228 0.182 0.137 0.000 0.000 0.000 0.000 0.000 0.000 1.641 0.137 0.000 0.046 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.319
Ž24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.912 0.273 0.501 0.684 0.729 0.957 0.912 1.003 0.547 0.547 0.319 0.182 0.046 0.137 0.273 0.319 8.341 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2194 183 183 2194 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON AT BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 8.28 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E2-125 Browns Ferry Nuclear Plant Units 1, 2, and 3 2011 Effluent and Waste Disposal Annual Report (See attached)
E3-1
2011 Effluent and Waste Disposal Annual Report Regulatory and BFN ODCM Limits A.
Fission and Activation Gases in Gaseous Effluent:
The release of fission and activation gases is regulated by the dose limits of 10 CFR 50 Appendix I and Browns Ferry Nuclear Plant (BFN) Offsite Dose Calculation Manual (ODCM). The air dose to areas at and beyond the site boundary due to noble gases released in gaseous effluents per unit shall be limited during any calendar quarter to < 5 millirad (mrad) for gamma radiation and < 10 mrad for beta radiation; and during any calendar year to
< 10 mrad for gamma radiation and < 20 mrad for beta radiation.
B.
lodines and Particulates with Half-Lives Greater than Eight Days in Gaseous Effluents:
The release of iodines and particulates in gaseous effluent is regulated by the dose limits of 10 CFR 50 Appendix I and the BFN ODCM. The dose to a member of the public from radioiodines, radioactive materials in particulate form, and radionuclides other than noble gases with half-lives greater than eight days in gaseous effluent released per unit to areas at and beyond the site boundary shall be limited to any organ during any calendar quarter to
< 7.5 millirem (mrem), and during any calendar year to < 15 mrem.
C.
Liquid Effluents:
The release of radioactive liquid effluents is regulated by the dose limits of 10 CFR 50 Appendix I and the BFN ODCM. The doses or dose commitment to a member of the public from radioactive materials in liquid effluents released from each unit to unrestricted areas shall be limited during any calendar quarter to < 1.5 mrem to the total body and <5 mrem to any organ and during any calendar year to < 3 mrem to the total body and < 10 mrem to any organ.
Limitation on Dose Rate A.
Fission and Activation Gases in Gaseous Effluents:
- 1. The instantaneous release rate of fission and activation gases is based on the dose rate limits of 10 CFR 20.1301 and the BFN ODCM. The dose rate at any time to areas at and beyond the site boundary due to noble gases released in gaseous effluents from the site shall be limited to
< 500 mrem per year to the total body and < 3000 mrem per year to the skin.
E3-2
2011 Effluent and Waste Disposal Annual Report Limitations on Dose Rate (Continued)
B.
lodines and Particulates with Half-Lives Greater than Eight Days in Gaseous Effluents:
- 1.
The instantaneous release rate of particulates and iodines is regulated by the dose rate limits of the BFN ODCM. The dose rate at any time to areas at and beyond the site boundary, due to 1-131, 1-133, H-3, and particulates with half-lives greater than eight days in gaseous effluent released from the site, shall be limited to < 1500 mrem per year to any organ.
- 2.
The BFN ODCM Section 7.3 determines the maximum particulate and iodine dose rates.
C.
Liquid Effluents:
- 1. The concentration of radionuclides in liquid effluents released at any time from the site to unrestricted areas shall be limited to the concentrations specified in 10 CFR 20.1001-20.2402, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases.
- 2. For dissolved or entrained noble gases, the concentration shall be limited to 2E-4.iCi per milliliter (ml) total activity.
Ill.
Measurements and Approximations of Total Radioactivity A.
Fission and Activation Gases:
- 1. Noble gases in the building vent and stack (elevated) gaseous effluents are continuously monitored. The flow rate of the stack is continuously monitored and the building vent effluent flow rates are calculated once a shift based on the configuration of operating exhaust fans. The vent flow is calculated for each release. Gas grab samples of the stack are taken and analyzed weekly. Gas grab samples of in-service vents are taken and analyzed monthly. The specific noble gas activity concentrations and total volume of the gases are used to calculate the total Curies of noble gases released.
- 2. The tritium concentration is determined by the analysis of a monthly grab sample for each release point.
E3-3
2011 Effluent and Waste Disposal Annual Report Ill.
Measurements and Approximations of Total Radioactivity (continued)
B.
lodines and Particulates:
- 1.
lodines and particulates are continuously sampled on impregnated charcoal filters and particulate filters, respectively. The charcoal and particulate samples are replaced at least weekly and analyzed to determine specific activity concentrations. The specific activity concentrations and vent flow rate data are used weekly to verify that release rate limits were not exceeded. The specific activity concentrations and total volume of gaseous effluent are used on a monthly basis to determine the total Curies of each particulate and iodine released during the month.
- 2.
The gross alpha concentration is determined by analysis of a monthly particulate filter composite sample, and strontium-89 and strontium-90 are determined by analysis of a quarterly particulate filter composite sample for each release point.
C.
Liquid Effluents:
- 1.
The gamma ray emitting radionuclide concentrations are determined for each batch by gamma ray spectroscopy analysis of a grab sample.
The allowable release rate is calculated for each batch based upon the known dilution flow. The flow rate of the liquid effluent is continuously monitored and the total volume released in each batch is determined.
The total gamma activity released in each batch is determined by multiplying the radionuclide concentrations by the total volume discharged. The total gamma activity released during the month is then determined by summing the gamma activity content of each batch discharged during the month.
- 2.
The gross alpha and tritium concentrations are measured on a monthly composite sample. The strontium-89, strontium-90, and iron-55 are measured on a quarterly composite sample.
D.
The Radioactive Gaseous and Liquid Waste Monitoring Sampling and Analysis Program is specified in ODCM Sections 1/2.2.1 and 1/2.2.2. No liquid or gaseous concentration or dose limits were exceeded.
E3-4
2011 Effluent and Waste Disposal Annual Report Supplemental Information IV.
Batch A. Liquid Units 1.
2.
3.
4.
5.
6.
Number of batches released Total time for batches released Maximum time period for a batch release Average time period for a batch release Minimum time period for a batch release Average BFN beach flow during period of release into the river stream Each Minutes Minutes Minutes Minutes ft3/sec Quarter 1
7 1451 240 207 100 66423 Quarter Quarter Quarter 2
3 4
11 2519 276 229 15 49084 B. Gaseous None C. Abnormal/Unplanned Releases*
Number of Releases: 2 Type: One Liquid/One Gas Total Activity Released (Curies)
Destination Leak to River Air Nuclide Quarter 1 Quarter 2 Quarter 3 Quarter 4 H-3 F-18 6.44E-02 5.80E-04 Ba-139 Cs-138 Kr-85m Ar-41 H-3 Sr-89 9.01E-08 5.03E-07 2.66E-03 8.26E-03 5.54E-04 6.08E-08
- - An explanation of any liquid or gaseous abnormal/unexplained releases shall be documented in the summary.
E3-5
2011 Effluent and Waste Disposal Annual Report Liquid Effluents - Summation of All Releases Units Quarter 1 Quarter 2 Quarter 3 Quarter 4 Error %
A. Fission and Activation Products (Does not include tritium, gases, Alpha)
- 1.
Total Release Curies 1.32E-02**
1.50E-03 9
- 2.
Average Diluted Concentration Released During Period gCi/ml 1.73E-09**
2.03E-10
- 3.
Percent of Applicable Limit B. Tritium
- 1.
Total Releases Curies 1.70E+00**
3.51E+00 6
- 2.
Average Diluted Concentration Released During Period
ýiCi/ml 2.23E-07**
4.73E-07
- 3.
Percent of Applicable Limit C. Dissolved and Entrained Noble Gases
- 1.
Total Releases Curies 2.15E-04 1.79E-05 8
- 2.
Average Diluted Concentration Released During Period gCi/ml 2.82E-1 1 2.41E-12
- 3.
Percent of Applicable Limit D. Gross Alpha Radioactivity
- 1.
Total Releases Curies 48
- 2.
Average Diluted Concentration Released During Period ICi/ml E. Volume of Liquid Waste to Discharge Canal (Prior to dilution)
Liters 5.95E+05 1.38E+06 3
F. Volume of Dilution Water for Period Liters 7.62E+09 7.42E+09 10 G. Total CCW Gigagal 2.24E+02 1.99E+02
- - Not Detected. Dilution flow was not determined for the abnormal release.
- - Includes activity from abnormal releases.
- The applicable limit is expressed in terms of dose. See Enclosure 1.
E3-6
2011 Effluent and Waste Disposal Annual Report Liquid Releases - Batch Mode CURIES Isotope (Required by Regulatory (REG) Guide 1.21)
Quarter 1 Quarter 2 Quarter 3 Quarter 4
- 1.
Ba-140 7.59E-05 4.94E-06
- 2.
Ce-141
- 3.
Co-58 3.90E-04 1.71E-05
- 4.
Co-60 5.77E-03 5.14E-04
- 5.
Cr-51
- 6.
Cs-134 1.70E-04 2.65E-05
- 7.
Cs-137 2.95E-03 8.44E-04
- 8.
Fe-59
- 9.
1-131 4.58E-05 3.37E-06
- 10.
La-140 8.18E-05 3.56E-06
- 11.
Mn-54 5.65E-04 3.87E-05
- 12.
Mo-99 8.40E-05 2.85E-06
- 13.
Nb-95
- 14.
Sr-89 1.13E-03
- 15.
Sr-90 1.43E-05
- 16.
Tc-99m 8.20E-05 2.78E-06
- 17.
Xe-133 1.31E-04
- 18.
Xe-135 8.37E-05 6.97E-06
- 19.
Zn-65 1.78E-04 1.29E-05
- 20.
Zr-95
- - Not Detected.
E3-7
2011 Effluent and Waste Disposal Annual Report Liquid Releases - Batch Mode CURIES Isotope Others (Not Required by REG Guide 1.21)
- 1.
F-18
- 2.
Fe-55 3
Mn-56 4
Zn-69m 5
Kr-88 6
Nb-97 7
Ag-ll0m 8
Sb-124 9
1-133 10 As-76 11 Na-24 12 Y-91m 13 Xe-133m
- - Activity from abnormal release.
- - Not Detected.
Quarter 1 6.37E-04*
1.08E-04 8.95E-07 4.93E-04 5.57E-05 2.60E-05 3.02E-04 1.70E-05 Quarter 2 5.24E-06 1.82E-05 2.98E-06 1.09E-05 Quarter 3 Quarter 4 E3-8
2011 Effluent and Waste Disposal Annual Report Gaseous Effluents - Summation of All Releases Units Quarter 1 Quarter 2 Quarter 3 Quarter 4 Error %
A. Fission and Activation Gases
- 1. Total Releases
- 2. Average Release Rate for Period
- 3. Percent of Applicable Limit B. lodines
- 1. Total Iodine-131
- 2. Average Release Rate for Period
- 3. Percent of Applicable Limit C. Particulates
- 1. Particulates with half-lives
> eight days
- 2. Average Release Rate for Period
- 3. Percent of Applicable Limit
- 4. Gross Alpha Radioactivity D. Tritium Curies jtCi/sec Curies pCi/sec Curies
- tCi/sec Curies 1*
.09E-02*
6.65E-O3*
45 3.32E-03 4.27E-04 1.82E-03 2.34E-04 3.25E-04 4.13E-04 1.39E-03*
1.77E-04*
2.68E-03 3.38E-04 1.81E-03 2.28E-04 2.03E-03 2.55E-04 9.58E-04 1.21E-04 36 35
- 1. Total Release Curies 2.58E+01 1.56E+01* 2.57E+01
- 2. Average Release Rate for Period pCi/sec 3.32E+00 1.99E+00* 3.23E+00
- 3. Percent of Applicable Limit E. Carbon-14***
- 1. Total Release Curies 8.45E+00 6.32E+00 9.81E+00
- 2. Total as CO2 Curies 8.03E+00 6.O1E+00 9.32E+00
- - Includes Activity from Abnormal Release
- - Not Detected.
- Estimated using EPRI methodology provided in EPRI Report 1021106.
- Applicable Limits are expressed in terms of dose. See Enclosure 1.
3.03E+01 21 3.81E+00 9.95E+00 9.45E+00 E3-9
2011 Effluent and Waste Disposal Annual Report Gaseous Effluents - Elevated Release CURIES I
Fission Gases Kr-85m Kr-85 Kr-87 Kr-88 Xe-133 Xe-135m Xe-135 Xe-138 Others (specify)
Total for Period
- 2.
lodines 1-131 1-133 Total for Period
- - Not Detected.
Quarter 1 Quarter 2 Quarter 3 Quarter 4 5.5 1E-04
- 1. 11E-03 1.66E-03 7.86E-04 1.13E-03 1.92E-03 6.36E-04 1.39E-03 2.03E-03 7.28E-04 1.43E-03 2.16E-03 E3-10
2011 Effluent and Waste Disposal Annual Report Gaseous Effluents - Elevated Release CURIES Quarter 1 Quarter 2 Quarter 3 Quarter 4
- 3.
Particulates*
Sr-89 1.40E-04 1.28E-04 1.99E-04 1.82E-04 Sr-90 Sr-91 8.25E-04 3.43E-04 2.61E-03 4.09E-03 Cs-134 Cs-137 Ba-140 8.15E-05 7.23E-05 1.87E-04 3.34E-04 La-140 4.91E-05 4.53E-05 1.24E-04 2.21E-04 Others (Au-199) 3.15E-06 2.76E-06 Others (Zn-69m) 7.06E-06 RB-89 5.85E-02 Y-91m 8.92E-04 6.23E-04 1.73E-03 2.55E-03 Cs-138 1.1OE-01 1.64E-02 2.85E-02 1.86E-02 Ba-139 6.54E-02 6.62E-02 1.86E-01 2.82E-01 Total for Period*
1.78E-01 8.38E-02 2.78E-01 3.08E-01
- 4.
Tritium 1.43E+00 4.12E+00 5.38E+00 3.60E+00
- 5.
Carbon-14***
8.45E+00 6.32E+00 9.8 1E+00 9.95E+00
- - Includes all nuclides, even those with less than an eight day half-life.
- - Not Detected.
- Estimated using EPRI methodology provided in EPRI Report 1021106.
E3-11
2011 Effluent and Waste Disposal Annual Report Gaseous Effluents - Ground Release CURIES Quax
- 1.
Fission Gases Kr-85m Kr-85 Kr-87 Kr-88 Xe-133 Xe-135m Xe-135 Xe-138 Ar-41 Other (specify)
Total for Period
- 2.
lodines 1-131 4.29]
1-133 1.73]
Total for Period 2.16]
- - Not Detected.
- - Activity from Abnormal Release.
-er 1 Quarter 2 2.66E-03*
8.26E-03"*
Quarter 3 Quarter 4 E-04 E-03 E-03 2.46E-04 1.17E-03 1.41E-03 5.39E-04 1.88E-03 2.42E-03 5.93E-04 2.49E-03 3.08E-03 E3-12
2011 Effluent and Waste Disposal Annual Report Gaseous Effluents - Ground Release CURIES Quarter 1 Quarter 2 Quarter 3 Quarter 4
- 3.
Particulates*
Co-60 Sr-89 4.95E-05 3.32E-05***
4.48E-05 5.05E-05 Sr-90 Cs-134 Cs-137 Ba-140 3.99E-05 1.59E-05 4.37E-05 8.45E-05 La-140 7.23E-06 1.14E-05 2.67E-05 Other (Sr-91) 9.66E-05 1.68E-04 4.64E-04 Other (Rb-89) 3.94E-03 Other (Au-199) 2.23E-06 Y-91m 1.44E-03 6.12E-04 8.84E-04 1.57E-03 Cs-138 1.80E-02 9.95E-03"**
1.96E-02 8.26E-02 Ba-139 4.06E-02 2.60E-02***
4.05E-02 8.49E-02 Total for Period*
6.01E-02 3.67E-02 6.52E-02 1.70E-01
- 4.
Tritium 5.13E+00 1.47E+00***
3.43E+00 7.41E+00
- - Include all nuclides even those with less than an eight day half-life.
- - Not Detected.
- ** - Includes Activity from Abnormal Release.
E3-13
2011 Effluent and Waste Disposal Annual Report Gaseous Effluents - Mixed Mode Release*
CURIES Quarter 1 Quarter 2 Quarter 3 Quarter 4 I
Fission Gases Kr-85m Kr-85 Kr-87 Kr-88 Xe-133 Xe-135m Xe-135 Xe-138 Other (specify)
Total for Period
- 2.
lodines 1-131 2.34E-03 2.21E-03 1.51E-03 7.03E-04 1-132 3.52E-03 1-133 1.19E-02 1.12E-02 6.58E-03 2.95E-03 1-135 9.97E-04 1.75E-03 Total for Period 1.88E-02 1.52E-02 8.09E-03 3.65E-03
- - The Reactor Building and Radwaste Building are treated as split-level releases.
- - Not Detected.
E3-14
2011 Effluent and Waste Disposal Annual Report Gaseous Effluents - Mixed Mode Release*
CURIES Quarter 1 Quarter 2 Quarter 3 Quarter 4
- 3.
Particulates**
Sr-89 6.73E-05 7.19E-05 3.19E-04 3.84E-05 Ce-141 6.25E-06 5.70E-06 Y-92 2.99E-03 Cs-137 1.91E-06 2.92E-06 Ba-140 8.82E-04 5.53E-04 2.55E-04 1.05E-04 La-140 6.57E-04 2.76E-04 1.14E-04 2.43E-05 Na-24 2.48E-05 Cr-51 2.22E-04 2.31E-05 Mn-54 2.60E-05 1.07E-05 3.91E-06 1.47E-05 Mn-56 4.90E-03 5.38E-03 5.82E-03 1.30E-02 Co-58 7.66E-05 2.65E-05 2.71E-05 5.45E-05 Co-60 1.98E-04 4.45E-04 7.09E-04 8.40E-05 Zn-65 2.61E-05 2.36E-05 6.09E-06 Zn-69m 5.35E-05 5.27E-05 2.71E-05 9.1OE-05 Y-91m 1.29E-02 7.96E-03 3.90E-03 1.51E-03 Sr-91 1.91E-02 8.52E-03 2.14E-03 1.65E-04 Sr-92 8.62E-03 1.52E-03
- - The Reactor Building and Radwaste Building are treated as split-level releases.
- - Includes all nuclides, even those with less than an eight day half-life.
- Not Detected.
E3-15
2011 Effluent and Waste Disposal Annual Report Gaseous Effluents - Mixed Mode Release*
CURIES Quarter 1 Quarter 2 Quarter 3 Quarter 4
- 3.
Particulates** (Continued)
Mo-99 2.19E-06 6.86E-06 3.30E-06 Tc-99m 2.14E-06 6.69E-06 3.22E-06 Cs-138 3.46E-02 2.81E-02 1.34E-02 Ba-139 3.18E-01 2.OOE-01 1.55E-01 6.30E-02 Total for Period**
3.69E-01 2.59E-01 1.96E-01 9.15E-02
- 4.
Tritium 1.92E+01 1.OOE+O1 1.69E+01 1.93E+OI
- - The Reactor Building and Radwaste Building are treated as split-level releases.
- - Includes all nuclides, even those with less than an eight day half-life.
- Not Detected.
E3-16
2011 Effluent and Waste Disposal Annual Report Solid Radioactive Waste Shipped for Processing or Disposal Resins, Filters, and RevaportorsBotomsVolume Curies Shipped Evaporator Bottoms Waste Class ft3 m3 Curies A
3.93E+3 1.11E+02 1.79E+02 B
0.OOE+00 0.OOE+00 0.OOE+00 C
0.OOE+00 0.OOE+00 0.OOE+00 ALL 3.93E+03 1.11E+02 1.79E+02 Major Nuclides for the Above Table:
1) 2)
3) 4)
5) 6)
7) 8)
9) 10) 11) 12) 13) 14) 15) 16) 17) 18) 19) 20) 21) 22) 23) 24) 25) 26) 27) 28) 29) 30) 31) 32) 33)
Nuclide Co-60 H-3 Fe-55 Mn-54 Zn-65 Ni-63 Na-24 Ag-ll0m Co-58 Cr-51 Ce-144 Co-57 C-14 Sr-92 Fe-59 Sr-90 Zr-97 1-133 1-131 Cs-138 Cs-137 Cs-134 La-141 La-140 Ce-141 Ba-140 Sb-125 Sb-124 Mo-99 Zr-95 Tc-99 Pu-241 Sr-89 Percentage 4.9 1E+01 9.99E-04 1.59E+01 5.25E+00 2.62E+00 1.85E+00 4.45E-07 1.60E+00 2.2 1E+00 4.67E-0 1 1.62E-01 3.97E-04 9.82E-02 6.92E-19 5.07E-02 3.15E-02 1.70E-07 4.03E-09 4.98E-01 1.19E-61 1.79E+01 1.23E+00 2.14E-13 4.08E-04 2.74E-01 7.20E-0 1 4.02E-04 2.40E-02 1.11E-04 9.94E-03 3.07E-02 2.70E-02 1.50E-03 Curies 8.80E+01 1.79E-03 2.84E+01 9.41E+00 4.70E+00 3.3 1E+00 7.98E-07 2.86E+00 3.96E+00 8.37E-01 2.90E-01 7.1 1E-04 1.76E-01 1.24E-18 9.09E-02 5.65E-02 3.05E-07 7.22E-09 8.92E-01 2.14E-61 3.20E+01 2.2 1E+00 3.84E-13 7.31E-04 4.91E-01 1.29E+00 7.20E-04 4.30E-02 1.98E-04 1.78E-02 5.50E-02 4.83E-02 2.68E-03 E3-17
2011 Effluent and Waste Disposal Annual Report 34) 35) 36) 37) 38) 39) 40) 41) 42) 43)
Nuclide Tc-99m Am-241 Cm-242 Cm-243 Cm-244 Pu-239 Pu-240 Pu-238 Cu-64 Zn-69m Percentage 9.43E-11 3.24E-04 1.09E-05 2.25E-04 2.68E-05 9.60E-06 9.60E-06 2.95E-05 7.42E-14 1.63E-12 Curies 1.69E-10 5.8 1E-04 1.96E-05 4.03E-04 4.8 1E-05 1.72E-05 1.72E-05 5.28E-05 1.33E-13 2.92E-12 Solid Radioactive Waste Shipped for Processing or Disposal Dry Active Waste Volume Curies Shipped Waste Class ft3 m 3 Curies A
5.29E+04 1.50E+03 4.51E-01 B
O.OOE+00 O.OOE+00 O.OOE+00 C
O.OOE+00 O.OOE+00 O.OOE+00 ALL 5.29E+04 1.50E+03 4.51E-01 Major Nuclides for the Above Table:
Nuclide
- 1)
Co-60 2) 3)
Ag-ll0m Fe-55
- 4)
Zn-65 5) 6)
7) 8)
9) 10) 11) 12)
Cs-137 Mn-54 Ni-63 H-3 Sr-89 Sr-90 Cs-134 Co-58 Percentage 6.52E+01 4.13E+00 1.20E+01 1.97E+00 1.17E+01 4.13E+00 7.57E-01 4.66E-02 0.OOE+00 1.08E-02 0.OOE+00 0.OOE+00 Curies 2.94E-01 1.86E-02 5.43E-02 8.86E-03 5.27E-02 1.86E-02 3.41E-03 2.1 0E-0 4
0.OOE+00 4.87E-05 0.OOE+00 O.OOE+O0 E3-18
2011 Effluent and Waste Disposal Annual Report Solid Radioactive Waste Shipped for Processing or Disposal Irradiated Components Volume Curies Shipped Waste Class ft3 m3 Curies A
0.OOE+00 O.OOE+00 0.OOE+00 B
0.OOE+00 0.OOE+00 0.00E+00 C
0.OOE+00 0.OOE+00 0.00E+00 ALL 0.OOE+00 O.OOE+00 0.OOE+00 Major Nuclides for the Above Table: N/A Solid Radioactive Waste Shipped for Processing or Disposal Other Waste Omied Pa ges Volume Curies Shipped (Combined Packages)
Waste Class ft3 m3 Curies A
4.64E+03 1.31E+02 1.81E+00 B
O.OOE+00 0.OOE+00 O.OOE+00 C
O.OOE+00 0.OOE+00 O.OOE+00 ALL 4.64E+03 1.31E+02 1.81E+00 Major Nuclides for the Above Table:
1) 2)
3) 4)
5) 6)
7) 8)
9) 10) 11) 12) 13) 14) 15) 16) 17) 18)
Nuclide Co-60 Cs-137 Ag-110m Fe-55 Zn-65 Mn-54 Ni-63 Cs-134 Co-58 H-3 Pu-241 Ce-144 C-14 Co-57 Sr-89 Sr-90 Tc-99 Pu-238 Percentage 5.64E+O1 1.62E+01 1.37E+00 1.62E+01 2.16E+00 3.88E+00 1.51E+00 1.31E+00 5.75E-01 1.24E-02 2.45E-02 1.47E-01 7.03E-02 1.81E-03 9.85E-02 2.69E-02 1.60E-04 2.81E-06 Curies 1.02E+00 2.93E-01 2.48E-02 2.92E-01 3.90E-02 7.02E-02 2.72E-02 2.37E-02 1.04E-02 2.24E-04 4.42E-04 2.66E-03 1.27E-03 3.28E-05 1.78E-03 4.86E-04 2.89E-06 5.07E-08 E3-19
2011 Effluent and Waste Disposal Annual Report 19) 20) 21)
Nuclide Am-241 Cm-242 Cm-243 Percentage 2.55E-04 4.84E-06 1.86E-04 Curies 4.6 1E-06 8.75E-08 3.37E-06 Solid Radioactive Waste Shipped for Processing or Disposal Sum of All Low-Level Waste Shipped from Volume Curies Shipped Site Waste Class ft3 m 3 Curies A
6.15E+04 1.74E+03 1.81E+02 B
0.OOE+00 O.OOE+00 0.OOE+00 C
0.OOE+00 0.OOE+00 0.OOE+00 ALL 6.15E+04 1.74E+03 1.81E+02 Major Nuclides for the Above Table:
1) 2)
3) 4)
5) 6)
7) 8)
9) 10) 11) 12) 13) 14) 15) 16) 17) 18) 19) 20) 21) 22) 23) 24) 25) 26) 27)
Nuclide Co-60 Cs-137 Fe-55 Mn-54 Zn-65 Ni-63 Cs-134 Ag-il0m Co-58 Cr-51 Ce-144 1-131 C-14 Ba-140 Fe-59 Sr-90 Na-24 Sb-124 Ce-141 La-141 Sb-125 Cs-138 Tc-99m Mo-99 Zr-97 Zr-95 Pu-241 Percentage 4.92E+01 1.78E+01 1.59E+01 5.24E+00 2.62E+00 1.84E+00 1.23E+00 1.60E+00 2.19E+00 4.61E-01 1.61E-01 4.92E-01 9.76E-02 7.11E-01 5.01E-02 3.15E-02 4.40E-07 2.37E-02 2.71E-01 2.12E-13 3.97E-04 1.18E-61 9.32E-11 1.09E-04 1.68E-07 9.81E-03 2.68E-02 Curies 8.93E+01 3.23E+01 2.88E+01 9.50E+00 4.75E+00 3.34E+00 2.23E+00 2.90E+00 3.98E+00 8.37E-01 2.92E-01 8.92E-0 1 1.77E-01 1.29E+00 9.09E-02 5.7 1E-02 7.98E-07 4.30E-02 4.91E-01 3.84E-13 7.20E-04 2.14E-61 1.69E-10 1.98E-04 3.05E-07 1.78E-02 4.87E-02 E3-20
2011 Effluent and Waste Disposal Annual Report 28) 29) 30) 31) 32) 33) 34) 35) 36) 37) 38) 39) 40) 41) 42) 43)
Nuclide Tc-99 Sr-89 H-3 Co-57 Am-241 Sr-92 Cm-242 Cm-243 Cm-244 La-140 Pu-239 Pu-240 Pu-238 1-133 Cu-64 Zn-69m Percentage 3.03E-02 2.46E-03 1.22E-03 4.1OE-04 3.23E-04 6.84E-19 1.09E-05 2.24E-04 2.65E-05 4.03E-04 9.48E-06 9.48E-06 2.92E-05 3.98E-09 7.33E-14 1.61E-12 Curies 5.50E-02 4.46E-03 2.22E-03 7.44E-04 5.86E-04 1.24E-18 1.97E-05 4.07E-04 4.8 1E-05 7.3 1E-04 1.72E-05 1.72E-05 5.29E-05 7.22E-09 1.33E-13 2.92E-12 E3-21
2011 Effluent and Waste Disposal Annual Report Summary of AbnormallUnplanned Releases The release of radioactive material to the environment from BFN has been a small fraction of the 10 CFR 20 Appendix B and 10 CFR 50 Appendix I limits. There were no limits exceeded as specified in 10 CFR 20 Appendix B and 10 CFR 50 Appendix I.
One abnormal liquid release occurred in 2011. A leak from a roughing cooler was detected to BFN Unit 3 station sump on January 13, 2011 (Problem Evaluation Report (PER) 324700). The BFN Unit 3 station sump sample analyzed on December 9, 2011, was clean but was used as the beginning period for the leak identified in 2011. The period of the release between December 9, 2010, and January 1, 2011, was reported in the Annual Radioactive Effluent Release Report for 2010. The BFN Unit 3 station sump was found to be clean on February 13, 2011.
One abnormal gaseous release occurred in 2011. On April 21, 2011, it was discovered that the ductwork access door below stack damper (2-DMP-66-92A) was missing bolts and leaking off-gas (PER 359503). This pathway, if secured, would have discharged through the elevated plant stack. Since the actual elevation of the leak was near ground level, the release was included in the ground level data.
Ground Water Monitoring Onsite groundwater monitoring locations were sampled during the year. These locations were not part of the BFN Radiological Environmental Monitoring Program (REMP). The purpose of these shallow wells was to monitor for potential leaks from plant equipment.
Trace levels of tritium were detected in several of these monitoring locations. BFN initiated a groundwater study to identify the source of the tritium. Results from a groundwater study completed in June 2006 suggest the source of the tritiated groundwater is associated with the Radwaste/Condensate Transfer tunnel. Water that may leak into the tunnel could egress via expansion joints and/or cracks through the tunnel wall. These joints and/or cracks were grouted during 2008 with several more leaks grouted in 2010. The highest concentration identified in the groundwater for the year was 1013 pCi/L. Groundwater and surface water level measurements during the study indicated the return channel and subsequently the Tennessee River will ultimately be recipient to tritiated groundwater discharge from the site. The estimated groundwater/channel water dilution ratio is 1:20,000 at a rate of approximately 0.5 gpm.
The tritium concentrations obtained in 2011 from these non-REMP wells are listed below.
Well ID Date Activity in pCi/L BH25 (1309) 5/5/11 590 DEWAT A(1311) 5/5/11 750 DEWAT A(1311) 10/20/11 559 DEWAT E(1312) 5/5/11 1013 E3-22
2011 Effluent and Waste Disposal Annual Report Summary of AbnormallUnplanned Releases Missed Compensatory Samples During the reporting period, January 1, 2011, through December 31, 2011, there was one missed compensatory sample. On April 27, 2011, six effluent continuous air monitors were found not operating due to the severe weather that occurred near the plant which resulted in the loss of off-site power and the shutdown of all three units. All six of the monitors were reset and a source check was performed to determine operability. The 1-RM-90-251, Turbine Building Effluent Radiation Monitor, failed the source check and remained inoperable. This allowed insufficient time to set up grab sample and flow readings. The monitor was declared inoperable on April 27, 2011, at 2330 hours0.027 days <br />0.647 hours <br />0.00385 weeks <br />8.86565e-4 months <br /> and the first flow and sample was obtained on April 28, 2011, at 0525 hours0.00608 days <br />0.146 hours <br />8.680556e-4 weeks <br />1.997625e-4 months <br />.
The ODCM requires a compensatory sample once per 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> and flow once per 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. This first flow reading exceeded the four hour time requirement. No activity was found in the sample. (PER 362404)
Liquid Radwaste or Temporary Storage Tanks BFN does not have outside liquid radwaste or temporary storage tanks that can be discharged directly to the environs (Technical Requirements Manual 3.7.1).
Changes to the Radwaste System and Changes to the Process Control Program In calendar year 2011, BFN had no changes to the radwaste system and no changes to the Process Control Program.
E3-23 Browns Ferry Nuclear Plant Units 1, 2, and 3 2011 Inoperable Radiological Effluent Instrumentation Report (See Attached)
E4-1
2011 Inoperable Radiological Effluent Instrumentation Report This report is to comply with Browns Ferry Nuclear Plant Offsite Dose Calculation Manual (ODCM) Sections 1/2.1.1 and 1/2.1.2. The ODCM requires the exertion of best efforts to return inoperable instruments to operable status within 30 days. Failure to return such instruments to an operable status within the prescribed interval requires a description in the Annual Radioactive Effluent Release Report.
During the reporting period, January 1, 2011, through December 31, 2011, there were no radioactive gaseous effluent monitoring instruments and no liquid effluent monitoring instruments out of service for greater than 30 days.