ML13126A100
| ML13126A100 | |
| Person / Time | |
|---|---|
| Site: | Browns Ferry (DPR-033, DPR-052, DPR-068) |
| Issue date: | 04/30/2013 |
| From: | James Shea Tennessee Valley Authority |
| To: | Document Control Desk, Office of Nuclear Reactor Regulation |
| References | |
| Download: ML13126A100 (176) | |
Text
Tennessee Valley Authority, 1101 Market Street, Chattanooga, Tennessee 37402 April 30, 2013 10 CFR 50.4 10 CFR 50.36a ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, D.C. 20555-0001 Browns Ferry Nuclear Plant, Units 1, 2, and 3 Facility Operating License Nos. DPR-33, DPR-52, and DPR-68 NRC Docket Nos. 50-259, 50-260, and 50-296
Subject:
2012 Annual Radioactive Effluent Release Report In accordance with the Browns Ferry Nuclear Plant (BFN), Units 1, 2, and 3, Technical Specification Section 5.6.3, the Tennessee Valley Authority is submitting the BFN Annual Radioactive Effluent Release Report for the period January through December 2012. This document is in conformance with Title 10 of the Code of Federal Regulations (10 CFR) 50.36a and 10 CFR Part 50, Appendix I Section IV.B.1. to the Enclosure documents deviations which have occurred from Offsite Dose Calculation Manual (ODCM) controls and surveillance requirements. Attachment 2 to the Enclosure provides information on radiological effluent instrumentation inoperable for greater than 30 days. There were no revisions to the ODCM during 2012.
There are no new regulatory commitments contained in this letter. Should you have any questions concerning this submittal, please contact Tom Hess, at (423) 751-3487.
Res
- ully, JWr hea ice resident, Nuclear Licensing
Enclosure:
2012 Annual Radioactive Effluent Release Report cc (w/ Enclosure):
NRC Regional Administrator - Region II NRC Senior Resident Inspector - Browns Ferry Nuclear Plant Printed on recycled paper
ENCLOSURE Browns Ferry Nuclear Plant Units 1, 2, and 3 2012 Annual Radioactive Effluent Release Report See Enclosed
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT TABLE OF CONTENTS Section Title Page Number Supplemental Information E E-10 Gaseous Effluents E E-19 Liquid Effluents E E-24 Solid Waste E E-31 Radiological Impact E E-47 Meteorological Data E E-171 (Deviations)
E-172 (Inoperable Instrumentation)
E-173 Tables Page Number Table 1A, Gaseous Effluents - Summation of All Releases E E-12 Table 1 B, Gaseous Effluents - Elevated Releases E E-14 Table 1C, Gaseous Effluents - Ground Level Releases E E-16 Table 1 D, Gaseous Effluents - Mixed Mode Releases E E-19 Table 2A, Liquid Effluents - Summation of All Releases E E-21 Table 2B, Liquid Effluents E E-24 Table 3, Solid Waste and Irradiated Fuel Shipments E E-31 Table 4, Radiological Impact, Doses from Airborne Effluents E E-42 Table 5, Radiological Impact, Doses from Liquid Effluents E E-46 Table 6, Radiological Impact, Total Dose from Fuel Cycle E-47 Table 7A, Meteorological Data, Joint Frequency Distribution E E-55 Ground Level Releases, First Quarter Table 7B, Meteorological Data, Joint Frequency Distribution E E-63 Ground Level Releases, Second Quarter E-1
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT TABLE OF CONTENTS Tables Page Number Table 7C, Meteorological Data, Joint Frequency Distribution E E-71 Ground Level Releases, Third Quarter Table 7D, Meteorological Data, Joint Frequency Distribution E E-79 Ground Level Releases, Fourth Quarter Table 8A, Meteorological Data, Joint Frequency Distribution E E-94 Split Level Releases, First Quarter Table 8B, Meteorological Data, Joint Frequency Distribution E E-109 Split Level Releases, Second Quarter Table 8C, Meteorological Data, Joint Frequency Distribution E-1 10 -
E-124 Split Level Releases, Third Quarter Table 8D. Meteorological Data, Joint Frequency Distribution E-125 -
E-139 Split Level Releases, Fourth Quarter Table 9A, Meteorological Data, Joint Frequency Distribution E-140 -
E-147 Elevated Releases, First Quarter Table 9B, Meteorological Data, Joint Frequency Distribution E-148 -
E-155 Elevated Level Releases, Second Quarter Table 9C, Meteorological Data, Joint Frequency Distribution E-156 -
E-163 Elevated Level Releases, Third Quarter Table 9D, Meteorological Data, Joint Frequency Distribution E-164 -
E-171 Elevated Level Releases, Fourth Quarter E-2
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SUPPLEMENTAL INFORMATION Regulatory and BFN ODCM Limits
- a. Fission and Activation Gases in Gaseous Effluent:
The release of fission and activation gases is regulated by the dose limits of Title 10 of the Code of Federal Regulations (10 CFR) 50 Appendix I and Browns Ferry Nuclear Plant (BFN) Offsite Dose Calculation Manual (ODCM). The air dose to areas at and beyond the site boundary due to noble gases released in gaseous effluents per unit shall be limited during any calendar quarter to < 5 millirad (mrad) for gamma radiation and < 10 mrad for beta radiation; and during any calendar year to < 10 mrad for gamma radiation and < 20 mrad for beta radiation.
- b. lodines and Particulates with Half-Lives Greater than Eight Days in Gaseous Effluents:
The release of iodines and particulates in gaseous effluent is regulated by the dose limits of 10 CFR 50 Appendix I and the BFN ODCM. The dose to a member of the public from radioiodines, radioactive materials in particulate form, and radionuclides other than noble gases with half-lives greater than eight days in gaseous effluent released per unit to areas at and beyond the site boundary shall be limited to any organ during any calendar quarter to < 7.5 millirem (mrem), and during any calendar year to < 15 mrem.
- c. Liquid Effluents:
The release of radioactive liquid effluents is regulated by the dose limits of 10 CFR 50 Appendix I and the BFN ODCM. The doses or dose commitment to a member of the public from radioactive materials in liquid effluents released from each unit to unrestricted areas shall be limited during any calendar quarter to < 1.5 mrem to the total body and <5 mrem to any organ and during any calendar year to
< 3 mrem to the total body and < 10 mrem to any organ.
- 2. Limitation on Dose Rate
- a. Fission and Activation Gases in Gaseous Effluent:
- 1. The instantaneous release rate of fission and activation gases is based on the dose rate limits of 10 CFR 20.1301 and the BFN ODCM. The dose rate at any time to areas at and beyond the site boundary due to noble gases released in gaseous effluents from the site shall be limited to < 500 mrem per year to the total body and < 3000 mrem per year to the skin.
E-3
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SUPPLEMENTAL INFORMATION
- 2. Limitation on Dose Rate (Continued)
- b. lodines and Particulates with Half-Lives Greater than Eight Days in Gaseous Effluents:
- 1. The instantaneous release rate of particulates and iodines is regulated by the dose rate limits of the BFN ODCM. The dose rate at any time to areas at and beyond the site boundary, due to 1-131, 1-133, H-3, and particulates with half-lives greater than eight days in gaseous effluent released from the site, shall be limited to < 1500 mrem per year to any organ.
- c. Liquid Effluents:
- 1. The concentration of radionuclides in liquid effluents released at any time from the site to unrestricted areas shall be limited to the concentrations specified in 10 CFR 20.1001-20.2402, Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained noble gases
- 2. For dissolved or entrained noble gases, the concentration shall be limited to 2E-4 ý.Ci per milliliter (ml) total activity.
- 3. Average Energy The BFN ODCM limits the dose equivalent rates due to the release of noble gases to less than or equal to 500 mrem/year to the total body and less than or equal to 3000 mrem/year to the skin. The use of dose rate is in accordance with NUREG-0133, "Preparation of Radiological Effluent Technical Specifications for Nuclear Power Plants." Since the release rate is not used for effluent control, the average beta and gamma energies (E) for gaseous effluents discussed in Regulatory Guide 1.21, "Measuring, Evaluation, and Reporting Radioactivity in Solid Wastes and Releases of Radioactive Materials in Liquid and Gaseous Effluents from Light-Water-Cooled Nuclear Power Plants," are not applicable and not included in this report.
E-4
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SUPPLEMENTAL INFORMATION
- 4. Measurements and Approximations of Total Radioactivity
- a. Fission and activation gases:
- 1. Noble gases in the building vent and stack (elevated) gaseous effluents are continuously monitored. The flow rate of the stack is continuously monitored and the building vent effluent flow rates are calculated once a shift based on the configuration of operating exhaust fans. The vent flow is calculated for each release. Gas grab samples of the stack are taken and analyzed weekly. Gas grab samples of in-service vents are taken and analyzed monthly. The specific noble gas activity concentrations and total volume of the gases are used to calculate the total Curies of noble gases released.
- 2. The tritium concentration is determined by the analysis of a monthly grab sample for each release point.
- b. lodines and Particulates:
- 1. lodines and particulates are continuously sampled on impregnated charcoal filters and particulate filters, respectively. The charcoal and particulate samples are replaced at least weekly and analyzed to determine specific activity concentrations. The specific activity concentrations and vent flow rate data are used weekly to verify that release rate limits were not exceeded. The specific activity concentrations and total volume of gaseous effluent are used on a monthly basis to determine the total curies of each particulate and iodine released during the month.
- 2. The gross alpha concentration is determined by analysis of a monthly particulate filter composite sample, and strontium-89 and strontium-90 are determined by analysis of a quarterly particulate filter composite sample for each release point.
- c. Liquid effluents:
- 1. The gamma ray emitting radionuclide concentrations are determined for each batch by gamma ray spectroscopy analysis of a grab sample. The allowable release rate is calculated for each batch based upon the known dilution flow.
The flow rate of the liquid effluent is continuously monitored and the total volume released in each batch is determined. The total gamma activity released in each batch is determined by multiplying the radionuclide concentrations by the total volume discharged. The total gamma activity released during the month is then determined by summing the gamma activity content of each batch discharged during the month.
E-5
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SUPPLEMENTAL INFORMATION
- 4. Measurements and Approximations of Total Radioactivity (Continued)
- c. Liquid effluents (Continued):
- 2. The gross alpha and tritium concentrations are measured on a monthly composite sample. The strontium-89, strontium-90, and iron-55 are measured on a quarterly composite sample.
- d. The Radioactive Gaseous and Liquid Waste Monitoring Sampling and Analysis Program is specified in ODCM Sections 1/2.2.1 and 1/2.2.2. No liquid or gaseous concentration or dose limits were exceeded.
- 5. Batch Releases Quarter Quarter Quarter Quarter 1
2 3
4
- a.
Liquid Units
- 1. Number of batches released
- 2. Total time for batches released
- 3. Maximum time period for a batch release
- 4. Average time period for a batch release
- 5. Minimum time period for a batch release
- 6. Average BFN beach flow during period of release into the river stream Note: There were no batch releases during the 2 nd, 3 rd, and 4 th quarters.
- b. Gaseous None Each Minutes Minutes 2
485.00 250.00 Minutes 242.50 Minutes 235.00 ft3/sec 74339 E-6
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SUPPLEMENTAL INFORMATION
- 6. Abnormal Releases
- a. Liquid
- 1. Number of releases: 4
- 2. Total activity released:
Destination Nuclide Quarter I Quarter 2 Quarter 3 Quarter 4 Leak to H-3 1.63E+00 8.42E-01 5.70E+00 River F-18 7.72E-02
- b. Gaseous
- 1. Number of releases: 2
- 2. Total activity released:
Destination Nuclide Quarter 1 Quarter 2 Quarter 3 Quarter 4 Air H-3 1.99E-02 5.49E-03 E-7
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SUPPLEMENTAL INFORMATION
- 6. Abnormal Releases (Continued)
Summary of Abnormal/Unplanned Releases The release of radioactive material to the environment from BFN has been a small fraction of the 10 CFR 20 Appendix B and 10 CFR 50 Appendix I limits. There were no limits exceeded as specified in 10 CFR 20 Appendix B and 10 CFR 50 Appendix I.
Four abnormal liquid releases occurred in 2012.
- 1.
From April 2, 2012 to April 4, 2012, a liquid release containing tritium was discharged from the pond structure. A sample from the sump trough on the north end of the Intake Cable Tunnel was obtained. It was discovered that a sump pump was hooked to a discharge line which ran the length of the tunnel and was open to discharge at the south end (forebay end) of the tunnel. The sump pump is located in an Radiologically Controlled Area (RCA) and discharged into a clean area (Problem Evaluation Report (PER) 532416)
- 2.
On September 13, 2012, the BFN, Unit 1 Station Sump was sampled at 0800.
The gamma isotopic analysis indicated the presence of Fluorine-18 (F-18). A resample was obtained at 0850 and it confirmed the presence of F-18 (PER 611022).
- 3.
From September 17, 2012 to September 21, 2012, a liquid release containing tritium was discharged from the pond structure (PER 621299).
- 4.
Beginning April 12, 2012, tritium was detected and released through the BFN Unit 1, Unit 2, and Unit 3 Station Sumps. The probable source was the Turbine Building Air Wash System (PER 536459 and PER 706704).
Two abnormal gaseous releases occurred in 2012.
- 1.
The Auxiliary Decay Heat Removal (ADHR) system was placed in service on April 9, 2012. The initial sample of the ADHR catch basin indicated tritium concentration at 1.33E-05 uCi/ml. The system was isolated on April 30, 2012 (PER 536466).
- 2.
On October 20, 2012, the ADHR system was returned to service. The initial sample of the ADHR catch basin following the return to service indicated tritium concentration at 2.1OE-06 uCi/ml. The system was isolated on December 1, 2012 (PER 706710).
E-8
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SUPPLEMENTAL INFORMATION
- 6. Abnormal Releases (Continued)
Ground Water Monitoring Onsite groundwater monitoring locations were sampled during the year. These locations were not part of the BFN Radiological Environmental Monitoring Program (REMP). The purpose of these shallow wells was to monitor for potential leaks from plant equipment. Trace levels of tritium were detected in several of these monitoring locations. BFN initiated a groundwater study to identify the source of the tritium.
Results from a groundwater study completed in June 2006 suggest the source of the tritiated groundwater is associated with the Radwaste/Condensate Transfer tunnel.
Water that may leak into the tunnel could egress via expansion joints and/or cracks through the tunnel wall. These joints and/or cracks were grouted during 2008 with several more leaks grouted in 2010. The highest concentration identified in the groundwater for the year was 3560 pCi/L. Groundwater and surface water level measurements during the study indicated the return channel and subsequently the Tennessee River will ultimately be recipient to tritiated groundwater discharge from the site. The estimated groundwater/channel water dilution ratio is 1:20,000 at a rate of approximately 0.5 gpm. The tritium concentrations obtained in 2012 from these non-REMP wells are listed below.
Well ID R-3 (1307)
R-3 (1307)
R-3 (1307)
BH25(1309)
BH25(1309)
BH25(1309)
BH25(1309)
BH25(1309)
BH25(1309)
BH25(1309)
BH25(1309)
BH25(1309)
BH25(1309)
BH25(1309)
BH25(1309)
Date 10/19/2012 7/24/2012 5/4/2012 12/21/2012 12/17/2012 11/14/2012 11/5/2012 10/29/2012 10/24/2012 10/18/2012 10/15/2012 10/9/2012 10/3/2012 9/24/2012 9/17/2012 Activity in pCi/L 381 255 396 694 542 753 540 531 588 637 648 689 679 668 671 Well ID BH25(1309)
BH25(1309)
DEWAT A(1311)
DEWAT A(1311)
DEWAT A(1311)
DEWAT A(1311)
DEWAT A(1311)
(PER 624796 and PER 679394)
DEWAT E(1312)
(PER 679394)
DEWAT E(1312)
DEWAT E(1312)
DEWAT E(1312)
DEWAT E(1312)
DSNO15 DSN 015b DSN150d Date 9/10/2012 5/4/2012 12/21/2012 11/8/2012 10/18/2012 7/24/2012 5/4/2012 12/21/2012 11/8/2012 10/18/2012 7/24/2012 5/4/2012 11/15/2012 11/16/2012 11/15/2012 Activity in pCi/L 385 296 846 1998 809 1600 3560 2946 1126 1409 300 348 227 209 221 E-9
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SUPPLEMENTAL INFORMATION
- 6. Abnormal Releases (Continued)
Liquid Radwaste or Temporary Storage Tanks BFN used three outside temporary liquid radwaste storage tanks to store approximately 55,000 gallons of radwaste water from March 10, 2012 to April 5, 2012. Concentrations of the tanks were monitored and verified to be less than the limits of 10 CFR 20, Appendix B, Table 2, Column 2, at the nearest potable water supply and the nearest surface water supply in an unrestricted area (Technical Specifications 5.5.8 (b) and Technical Requirements Manual 3.7.1).
Changes to the Radwaste System and Changes to the Process Control Program In calendar year 2012, BFN had no changes to the radwaste system. The Process Control Program was revised on January 26, 2012.
E-10
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT GASEOUS EFFLUENTS TABLE 1A Page 1 of 2 Gaseous Effluents - Summation of All Releases Units Quarter 1 Quarter 2 Quarter 3 Quarter 4 Error %
A. Fission and Activation Gases
- 1. Total Releases
- 2. Average Release Rate for Period
- 3. Percent of Applicable Limit B. lodines
- 1. Total Iodine-131
- 2. Average Release Rate for Period
- 3. Percent of Applicable Limit C. Particulates
- 1. Particulates with half-lives
> eight days
- 2. Average Release Rate for Period
- 3. Percent of Applicable Limit
- 4. Gross Alpha Radioactivity D. Tritium Curies
ýtCi/sec Curies
[tCi/sec Curies jtCi/sec Curies 2.7 1E-03 3.44E-04 9.02E-04 1.15E-04 3.99E+02 5.02E+O I 1.70E-03 2.17E-04 7.73E-04 9.83E-05 2.24E-03 2.82E-04 4.2 1E-04 5.30E-05 2.94E+02 3.70E+01 1.77E-03 2.23E-04 4.54E-04 5.7 1E-05 45 36 35 21
- 1. Total Release Curies 4.16E+02 6.22E+01* 6.90E+01 4.97E+01*
- 2. Average Release Rate for Period p.Ci/sec 5.29E+01 7.92E+00* 8.68E+00 6.25E+00*
- 3. Percent of Applicable Limit E-1 1
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT GASEOUS EFFLUENTS TABLE 1A (Continued)
Page 2 of 2 Gaseous Effluents - Summation of All Releases Units Quarter 1 Quarter 2 Quarter 3 Quarter 4 Error %
E. Carbon-14***
- 1. Total Release Curies 9.93E+00 7.76E+00 1.02E+01 8.22E+00 N/A
- 2. Total as CO 2 Curies 9.43E+00 7.37E+00 9.69E+00 7.81E+00
- Includes Activity from Abnormal Release
- Not Detected.
- Estimated using Electric Power Research Institute (EPRI) methodology provided in EPRI Report 1021106.
- Applicable Limits are expressed in terms of dose. See Radiological Impact Report.
E-1 2
EF CURIES I
Fission Gases Kr-85m Kr-85 Kr-87 Kr-88 Xe-133 Xe-135m Xe-135 Xe-138 Others (N-13)
Total for Period
- 2.
lodines 1-131 1-135 1-133 Total for Period
- - Not Detected.
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 FLUENT AND WASTE DISPOSAL ANNUAL REPORT GASEOUS EFFLUENTS (Continuous Mode Only)
TABLE 1B Page 1 of 2 Gaseous Effluents - Elevated Releases Quarter I Quarter 2 Quarter 3 5.9E0 1.4E0 1.3E0 3.49E+00 3.96E+02 3.99E+02 Quarter 4 2.94E+02 2.94E+02 2.73E-04 5.62E-04 8.35E-04 3.96E-04 5.41E-04 1.05E-03 1.99E-03 5.35E-04 1.30E-03 1.83E-03 E-13
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT GASEOUS EFFLUENTS (Continuous Mode Only)
TABLE 1B (Continued)
Page 2 of 2 Gaseous Effluents - Elevated Releases Quarter I Quarter 2 Quarter 3 CURIES
- 3.
Particulates*
Sr-89 Sr-90 Sr-91 1.47E-04 1.03E-04 1.88E-04 2.3 1E-03 Quarter 4 1.87E-04 2.72E-03 2.67E-03 9.48E-04 Cs-134 Cs-137 Ba-140 La-140 Te-132 Others (Zn-69m)
Others (Au-199) 2.38E-04 1.45E-04 7.03E-07 1.07E-04 6.8 1E-05 RB-89 2.29E-02 Y-91m 1.81E-03 8.53E-04 Cs-138 7.32E-03 Ba-139 2.07E-01 8.57E-02 Total for Period*
2.42E-01 8.78E-02
- 4.
Tritium 2.68E+00 2.43E+00
- 5.
Carbon-14***
9.43E+00 7.37E+00
- - Includes all nuclides, even those with less than an eight day half-life.
- - Not Detected.
- Estimated using EPRI methodology provided in EPRI Report 1021106.
2.33E-04 1.56E-04 9.17E-06 1.22e-06 1.80E-03 2.48E-0 1 2.53E-01 5.39E+00 9.69E+00 2.67E-04 1.83E-04 1.97E-03 2.41E-01 2.46E-0 1 3.97E+00 7.8 1E+00 E-14
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT GASEOUS EFFLUENTS (Continuous Mode Only)
TABLE 1C Page 1 of 2 Gaseous Effluents - Ground Level Releases CURIES Quat Fission Gases Kr-85m Kr-85 Kr-87 Kr-88 Xe-133 Xe-135m Xe-135 Xe-138 Ar-41 Other (specify)
Total for Period
- 2.
lodines 1-131 1.031 1-132 4.611 1-133 4.251 Total for Period 5.331
- - Not Detected.
- - Activity from Abnormal Release.
-ter 1 Quarter 2 Quarter 3 Quarter 4
--03
,-03
~-03 4.53E-04 5.42E-04 9.95E-04 3.49E-04 1.16E-03 1.5 1E-03 4.69E-04 1.83E-03 2.30E-03 E-1 5
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT GASEOUS EFFLUENTS (Continuous Mode Only)
TABLE 1C (Continued)
Page 2 of 2 Gaseous Effluents - Ground Level Releases CURIES Quarter 1 Quarter 2 Quarter 3
- 3. Particulates*
Co-60 2.53E-05 7.81E-06 Sr-89 6.26E-05 9.85E-07 Sr-90 Cs-134 Cs-137 Ba-140 9.95E-05 5.69E-06 La-140 5.05E-05 2.67E-06 Sr-91 8.21E-04 1.63E-05 Other (Mn-54) 2.89E-06 Other (Au-199)
Y-91m 2.28E-03 7.85E-05 6.15E-05 Cs-138 2.42E-02 Ba-139 1.05E-01 6.04E-03 4.93E-03 Total for Period*
1.32E-01 6.17E-03 5.00E-03
- 4.
Tritium 9.32E+00 2.70E+00***
8.95E-01
- - Include all nuclides even those with less than an eight day half-life.
- - Not Detected.
- Includes Activity from Abnormal Release.
Quarter 4 1.54E-05 1.25E-05 4.17E-04 1.3 1E-02 1.66E-02 3.0 1E-02 5.68E+00***
E-16
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT GASEOUS EFFLUENTS (Continuous Mode Only)
TABLE 1D Page 1 of 3 Gaseous Effluents - Mixed Mode Releases CURIES Quarter 1 Quarter 2 Quarter 3 Quarter 4 1
Fission Gases Kr-85m Kr-85 Kr-87 Kr-88 Xe-133 Xe-135m Xe-135 Xe-138 Other (specify)
Total for Period
- 2.
Iodines 1-131 1.09E-03 8.53E-04 1.36E-03 1.03E-03 1-132 4.63E-04 1-133 5.19E-03 2.86E-03 6.20E-03 5.24E-03 Total for Period 6.73E-03 3.7 1E-03 7.56E-03 6.27E-03
- - The Reactor Building and Radwaste Building are treated as split-level releases.
- - Not Detected.
E-17
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT GASEOUS EFFLUENTS (Continuous Mode Only)
TABLE ID (Continued)
Page 2 of 3 Gaseous Effluents - Mixed Mode Releases CURIES Quarter 1 Quarter 2 Quarter 3 Quarter 4
- 3.
Particulates**
Sr-89 5.56E-05 1.36E-06 4.69E-05 8.23E-04 Ru-103 3.50E-06 Ag-i 10m*
4.93E-06 4.28E-05 Cs-137 3.23E-05 4.87E-06 2.55E-05 1.89E-05 Ba-140 1.59E-04 5.91E-05 1.48E-04 3.33E-04 La-140 7.2 1E-05 3.50E-05 3.3 1E-05 1.53E-04 Na-24 5.56E-05 1.45E-04 1.75E-04 Cr-51 2.04E-05 3.50E-05 Mn-54 1.56E-05 1.79E-05 4.59E-05 6.70E-05 Mn-56 1.17E-02 9.98E-03 1.97E-02 2.70E-02 Co-58 4.44E-05 1.97E-05 1.02E-04 9.32E-05 Co-60 3.38E-05 4.08E-04 5.05E-04 3.39E-04 Zn-65 1.36E-05 5.66E-05 4.92E-05 Zn-69m 4.22E-05 1.80E-05 7.75E-05 9.51E-05 Y-91m 2.90E-03 6.78E-04 1.85E-03 3.22E-03 Sr-91 3.13E-03 1.23E-04 8.94E-04 2.63E-03 Sr-92 4.98E-04
- - The Reactor Building and Radwaste Building are treated as split-level releases.
- - Includes all nuclides, even those with less than an eight day half-life.
- Not Detected.
E-18
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT GASEOUS EFFLUENTS (Continuous Mode Only)
TABLE ID (Continued)
Page 3 of 3 Gaseous Effluents - Mixed Mode Releases CURIES Quarter I Quarter 2 Quarter 3 Quarter 4
- 3.
Particulates** (Continued)
Mo-99 1.62E-06 2.12E-06 1.74E-06 Tc-99m 1.58E-06 2.07E-06 1.70E-06 Cs-138 7.51E-03 1.1OE-02 1.91E-02 Ba-139 1.26E-01 1.56E-02 7.16E-02 1.16E-01 Y-92 7.14E-04 Total for Period**
1.52E-01 2.70E-02 1.06E-01 1.71E-01
- 4.
Tritium 4.04E+02 5.71E+O1 6.27E+01 4.01E+O1
- - The Reactor Building and Radwaste Building are treated as split-level releases.
- - Includes all nuclides, even those with less than an eight day half-life.
- Not Detected.
E-1 9
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT LIQUID EFFLUENTS (Batch Mode Only)
TABLE 2A Page 1 of 2 Liquid Effluents - Summation of All Releases Units Quarter 1 Quarter 2 Quarter 3 Quarter 4 Error %
A. Fission and Activation Products (Does not include tritium, gases, Alpha)
- 1.
Total Release
- 2.
Average Diluted Concentr.ation Curies 9.43E-04 Released During Period Percent of Applicable Limit 7.72E-02**
1.44E-07"*
9 jICi/ml 3.67E-10 3.
B. Tritium
- 1.
Total Releases
- 2.
Average Diluted Concentration Released During Period
- 3.
Percent of Applicable Limit C. Dissolved and Entrained Noble Gases
- 1.
Total Releases
- 2.
Average Diluted Concentration Released During Period
- 3.
Percent of Applicable Limit D. Gross Alpha Radioactivity
- 1.
Total Releases
- 2.
Average Diluted Concentration Released During Period Curies 1.41E+00 1.63E+00** 8.42E-01** 5.70E+00**
6 j.Ci/ml Curies
[tCi/ml 5.49E-07 4.98E-03**
1.58E-06**
1.97E-05**
8 Curies P.Ci/ml
- g 48 E-20
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT LIQUID EFFLUENTS (Batch Mode Only)
TABLE 2A (Continued)
Page 2 of 2 Liquid Effluents - Summation of All Releases Units Quarter I Quarter 2 Quarter 3 Quarter 4 Error %
E. Volume of Liquid Waste to Discharge Canal (Prior to dilution)
Liters 2.61E+05 4.67E+08** 6.32E+08** 2.89E+08**
3 F. Volume of Dilution Water for Period Liters 2.57E+09 10 G. Total CCW Gigagal 2.31E+02 2.23E+02 2.66E+02 2.34E+02
- - Not Detected.
- - Includes activity from abnormal releases. Dilution flow was not determined for the abnormal releases.
- The applicable limit is expressed in terms of dose. See Radiological Impact Report.
E-21
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT LIQUID EFFLUENTS (Batch Mode Only)
TABLE 2B Page 1 of 3 Liquid Effluents CURIES Isotope (Required by Regulatory (REG) Guide 1.21)
Quarter 1 Quarter 2 Quarter 3 Quarter 4
- 1.
Ba-140
- 2.
Ce-141
- 3.
Co-58
- 4.
Co-60 3.02E-04
- 5.
Cr-51
- 6.
Cs-134 1.23E-05
- 7.
Cs-137 6.01E-04
- 8.
Fe-59
- 9.
1-131
- 10.
La-140
- 11.
Mn-54 1.30E-05
- 12.
- 13.
Nb-95
- 14.
Sr-89
- 15.
- 16.
Tc-99m
- 17.
- - Not Detected.
E-22
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT LIQUID EFFLUENTS (Batch Mode Only)
TABLE 2B (Continued)
Page 2 of 3 Liquid Effluents CURIES Isotope (Required by Regulatory (REG) Guide 1.21)
Quarter 1 Quarter 2 Quarter 3 Quarter 4
- 18.
Xe-135
- 19.
Zn-65
- 20.
Zr-95
- - Not Detected.
E-23
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT LIQUID EFFLUENTS (Batch Mode Only)
TABLE 2B (Continued)
Page 3 of 3 Liquid Effluents CURIES Isotope Others (Not Required by REG Guide 1.21)
Quarter 1 Quarter 2 Quarter 3 Quarter 4
- 1.
F-18
- 2.
Fe-55 7.72E-02*
7.74E-06 3
Mn-56 4
Zn-69m 5
Kr-88 6
Nb-97 7
Ag-110m 8
Sb-124 9
1-133 10 As-76 11 Na-24 12 Y-91m 13 Xe-133m
- - Activity from abnormal release.
- - Not Detected.
6.68E-06 E-24
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SOLID WASTE TABLE 3 Page 1 of 7 Solid Waste and Irradiated Fuel Shipments A. Solid Waste Shipped Offsite for Burial or Disposal (not Irradiated Fuel)
- 1. Type of Waste Unit Jan - Jun 2012 July-Dec 2012
- a. Spent resins, filters, sludges, evaporator m3 1.53E+02 9.80E+0 1 bottoms, etc.
Ci 6.29E+02 6.01E+02
- b. Dry Active Waste, Compressible Waste m3 2.25E+03 1.48E+03 Contaminated Equipment, etc.
Ci 1.97E+01 5.88E-01
- c. Irradiated Components, Control Rods, etc.
m3 0.OOE+00 3.18E+00 Ci O.OOE+00 1.86E+04
- d. Other (Describe) m3 4.67E+01 3.77E+01 Ci 1.09E+00 9.09E-01 Error %
+/- 25%
+/- 25%
+/- 25%
+/- 25%
+/- 25%
+/- 25%
+/- 25%
+/- 25%
E-25
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SOLID WASTE TABLE 3 (Continued)
Page 2 of 7 Solid Waste and Irradiated Fuel Shipments
- 2. Estimate of Major Nuclide Composition
- a. Spent resins, filters, sludges, evaporator bottoms, etc.
Nuclide Percent Curies H-3 3.29E-02 4.04E-01 C-14 5.38E-02 6.62E-01 Cr-51 9.76E-02 1.20E+00 Mn-54 3.46E+00 4.26E+01 Fe-55 1.70E+01 2.09E+02 Fe-59 1.59E-02 1.95E-01 Co-57 2.32E-03 2.85E-02 Co-58 6.71E-01 8.25E+00 Co-60 4.27E+01 5.25E+02 Ni-59 5.01E-04 6.16E-03 Ni-63 1.20E+00 1.48E+01 Cu-64 2.66E-07 3.27E-06 Zn-65 2.07E+00 2.54E+01 Zn-69m 2.85E-15 3.51E-14 Sr-89 8.78E-03 1.08E-01 Sr-90 4.11E-02 5.05E-01 Zr-95 4.58E-05 5.63E-04 Nb-95 5.50E-05 6.77E-04 Mo-99 5.58E-06 6.86E-05 Tc-99 1.36E-02 1.67E-01 Tc-99m 2.39E-22 2.94E-21 Ag-1 10m 3.68E-01 4.53E+00 Sb-124 4.86E-05 5.98E-04 Te-132 6.25E-46 7.69E-45 1-129 1.24E-05 1.52E-04 1-131 4.98E-02 6.13E-01 1-133 9.11E-08 1.12E-06 Cs-134 1.74E+00 2.14E+O1 Cs-136 6.72E-45 8.27E-44 Cs-137 3.03E+01 3.73E+02 Ba-140 6.07E-02 7.46E-01 La-140 1.85E-03 2.27E-02 E-26
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SOLID WASTE TABLE 3 (Continued)
Page 3 of 7 Solid Waste and Irradiated Fuel Shipments
- 2. Estimate of Major Nuclide Composition (Continued)
- a. Spent resins, filters, sludges, evaporator bottoms, etc. (Continued)
Nuclide Percent Curies Ce-141 2.50E-02 3.08E-01 Ce-144 3.89E-02 4.78E-01 Pu-238 2.53E-04 3.11E-03 Pu-239 9.59E-06 1.18E-04 Pu-240 9.59E-06 1.18E-04 Pu-241 3.07E-02 3.77E-01 Am-241 1.26E-04 1.55E-03 Cm-242 1.37E-05 1.69E-04 Cm-243 1.52E-04 1.87E-03 Cm-244 1.03E-04 1.27E-03 E-27
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SOLID WASTE TABLE 3 (Continued)
Page 4 of 7 Solid Waste and Irradiated Fuel Shipments
- 2. Estimate of Major Nuclide Composition (Continued)
- b. Dry Active Waste, Compressible Waste Contaminated Equipment, etc.
Nuclide Percent Curies H-3 2.37E+01 4.81E+00 C-i14 2.23E-03 4.52E-04 K-40 1.99E-01 4.04E-02 Cr-51 8.38E-04 1.70E-04 Mn-54 8.23E+00 1.67E+00 Fe-55 2.28E+01 4.62E+00 Fe-59 1.29E-03 2.61E-04 Co-58 1.02E+00 2.06E-01 Co-60 3.45 E+O1 7.OOE+00 Ni-63 1.40E+00 2.83E-01 Zn-65 4.77E+00 9.68E-01 Sr-89 2.56E-02 5.20E-03 Sr-90 4.93E-03 1.00E-03 Zr-95 1.15E-04 2.33E-05 Nb-95 O.OOE+00 O.OOE+00 Tc-99 6.46E-03 1.3 1E-03 Ag-11Om 1.81E+00 3.67E-01 Sb-124 2.31E-04 4.68E-05 1-131 8.82E-06 1.79E-06 Cs-134 2.89E-02 5.86E-03 Cs-137 1.11E+00 2.26E-01 Ba-140 8.28E-05 1.68E-05 La-140 1.77E-17 3.60E-18 Ce-141 2.57E-04 5.22E-05 Ce-144 3.56E-01 7.23E-02 Pu-238 1.14E-04 2.32E-05 Pu-239 1.37E-05 2.77E-06 Pu-240 1.37E-05 2.77E-06 Pu-241 3.45E-02 6.99E-03 Am-241 7.99E-05 1.62E-05 Cm-242 2.41E-04 4.89E-05 Cm-243 1.68E-05 3.40E-06 Cm-244 1.68E-05 3.40E-06 E-28
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SOLID WASTE TABLE 3 (Continued)
Page 5 of 7 Solid Waste and Irradiated Fuel Shipments
- 2. Estimate of Major Nuclide Composition (Continued)
- c. Irradiated Components, Control Rods, etc.
Nuclide Percent Curies H-3 2.22E-03 4.14E-01 C-I14 1.26E-02 2.35E+00 Mn-54 4.89E-01 9.1OE+O1 Fe-55 4.81E+O1 8.95E+03 Co-60 4.42E+O1 8.23E+03 Ni-59 3.61E-02 6.72E+00 Ni-63 7.17E+00 1.34E+03 Nb-94 1.33E-04 2.47E-02 Tc-99 5.71E-05 1.06E-02 U-235 2.71E-10 5.05E-08 Np-237 7.58E-09 1.41E-06 Pu-238 1.14E-04 2.13E-02 Pu-239 9.90E-08 1.84E-05 Pu-240 1.68E-07 3.13E-05 Pu-241 2.05E-05 3.82E-03 Am-241 2.03E-07 3.79E-05 Am-243 6.89E-09 1.28E-06 Cm-242 3.99E-08 7.42E-06 Cm-243 6.27E-09 1.17E-06 Cm-244 1.70E-06 3.17E-04 E-29
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SOLID WASTE TABLE 3 (Continued)
Page 6 of 7 Solid Waste and Irradiated Fuel Shipments
- 2. Estimate of Major Nuclide Composition (Continued)
- d. Other (Combined Packages)
Nuclide Percent Curies H-3 6.56E-03 1.31E-04 C-14 4.89E-02 9.77E-04 Mn-54 3.79E+00 7.56E-02 Fe-55 1.34E+01 2.67E-0I Co-58 4.70E-0I 9.39E-03 Co-60 6.31E+O1 1.26E+00 Ni-63 1.12E+00 2.23E-02 Zn-65 2.06E+00 4.11E-02 Sr-89 5.21E-02 1.04E-03 Sr-90 2.05E-02 4.09E-04 Nb-95 9.11E-02 1.82E-03 Tc-99 1.05E-04 2.1OE-06 Ag-110m 1.26E+00 2.51E-02 Cs-134 9.71E-0I 1.94E-02 Cs-137 1.34E+OI 2.68E-01 Ce-141 7.01E-02 1.40E-03 Ce-144 1.50E-01 2.99E-03 Pu-238 3.26E-06 6.52E-08 Pu-239 1.26E-06 2.51E-08 Pu-241 1.80E-02 3.59E-04 Am-241 1.86E-04 3.71E-06 Cm-242 6.56E-06 1.31E-07 Cm-243 1.34E-04 2.67E-06 E-30
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SOLID WASTE TABLE 3 (Continued)
Page 7 of 7 Solid Waste and Irradiated Fuel Shipments
- 3. Solid Waste Disposition Number of Shipments 66 54 6
2 29 2
40 5
Mode of Transportation Cask, tankers, Sole Use Trucks (Hittman)
Sole Use Trucks (Tri-State)
Sole Use Truck (TVA HED)
Non Sole Use Trucks (Hittman)
Sole Use Tucks Sole Use Trucks, Tankers Casks (Hittman)
Non Sole Use Trucks (Tri-State)
Sole Use Trucks and Tankers (Hittman)
Sole Use Trucks, Cask (Hittman)
Destination Energy Solutions Oak Ridge, TN (Bear Creek)
Energy Solutions Oak Ridge, TN (Bear Creek)
Energy Solutions Oak Ridge, TN (Bear Creek)
Energy Solutions Memphis, TN Energy Solutions Memphis, TN Energy Solutions Oak Ridge, TN (Kingston)
Energy Solutions Oak Ridge, TN (Kingston)
Barnwell Processing Facility Barnwell, SC Waste Control Specialist Andrews, TX B. Irradiated Fuel Shipments Number of Shipments 2
Mode of Transportation Hittman Destination Waste Control Specialist Andrews, TX E-31
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SOLID WASTE E-32
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT RADIOLOGICAL IMPACT
- 1. Introduction Potential doses to the "maximum exposed individual" and the population around Browns Ferry Nuclear Plant (BFN) are calculated for each quarter as required in Section 5.2 of the Offsite Dose Calculation Manual (ODCM). The methodology used to estimate dose for determining plant releases for the reporting period is specified in Sections 6 and 7 of the ODCM.
Dispersion of radioactive effluents in the environment is estimated using meteorological data and river flow measured during the period. In this report, the doses resulting from releases are described and compared to limits established for BFN.
- 2. Dose Limits The ODCM specifies limits for the release of radioactive effluents, as well as limits for doses to the general public from the release of radioactive effluents. These limits are set well below the Technical Specification limits which govern the concentrations of radioactivity and doses permissible in unrestricted areas. This ensures that radioactive effluent releases are As Low As Reasonably Achievable.
The air dose limits in areas at and beyond the Site Boundary due to noble gases released in gaseous effluents per unit are:
< 5 mrad per quarter and
< 10 mrad per year for gamma radiation.
- and -
< 10 mrad per quarter and
< 20 mrad per year for beta radiation.
The dose limits to a member of the public in an unrestricted area from radioiodines, radioactive materials in particulate form, and radionuclides other than noble gases with half-lives > 8 days released in gaseous effluents for each unit are:
< 7.5 mrem per quarter and
< 15 mrem per year to any organ.
The dose or dose commitment to a member of the public from radioactive material in liquid effluents released to unrestricted areas are:
< 1.5 mrem per quarter and
< 3 mrem per year to the total body,
- and -
< 5 mrem per quarter and
< 10 mrem per year to any organ.
The limit for the total effective dose equivalent to an individual member of the public inside the site boundary is:
100 mrem per year.
E-33
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT RADIOLOGICAL IMPACT
- 2. Dose Limits (Continued)
The Environmental Protection Agency limits for total dose to any member of the public in the vicinity of a nuclear power plant, established in the Environmental Dose Standard of 40 CFR 190, are:
< 25 mrem per year to the whole body,
< 75 mrem per year to the thyroid,
- and -
< 25 mrem per year to any other organ.
- 3. Dose Calculations Estimated doses to members of the public are determined using computer models (the Gaseous Effluent Licensing Code, and the Quarterly Water Dose Assessment Code (QWATA)).
These models are based on guidance provided by the Nuclear Regulatory Commission (NRC) for determining the potential dose to individuals and populations living in the vicinity of the plant. The area around the plant is analyzed to determine the pathways through which the public may receive a dose. The doses calculated are a representation of the dose to a "maximum exposed individual." Some of the factors used in these calculations (such as ingestion rates) are maximum values to ensure conservative reporting data. The values chosen will tend to overestimate the dose. The expected dose to actual individuals is lower. The calculated doses are presented in Tables 4, 5, and 6.
- 4. Doses From Airborne Effluents For airborne effluents, members of the public can be exposed to radiation from several sources: direct radiation from the radioactivity in the air, direct radiation from radioactivity deposited on the ground, inhalation of airborne radioactivity, ingestion of vegetation which contains radioactivity deposited from the atmosphere, and ingestion of milk and beef which contains radioactivity deposited from the atmosphere onto vegetation and subsequently consumed by animals.
- a. Airborne Release Points There are four monitored release points from BFN: the turbine building, the radwaste building, the reactor building, and the stack.
Releases from the turbine building are considered ground-level releases. The ground-level Joint Frequency Distribution (JFD) is derived from wind speeds and directions measured 10.5 meters above the ground and from the vertical temperature difference between 10.03 and 45.30 meters, and are presented for each quarter in the 2012 Meteorological Data Tables 7A, 7B, 7C, and 7D.
E-34
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT RADIOLOGICAL IMPACT
- 4. Doses From Airborne Effluents (Continued)
- a. Airborne Release Points (Continued)
Releases from the radwaste and reactor buildings are considered split-level releases.
Portions of the release are treated as ground-level while other portions are considered elevated depending on the ratio of the vertical exit velocity to the horizontal wind speed.
The split-level dispersion approach is implemented using a model that requires two complete quarterly JFDs for each effluent vent, one for the ground-level releases and one for the elevated releases. The ground-level portion of the split-level JFD is based on wind speeds and directions measured 10.5 meters above ground-level and from the vertical temperature difference between 10.03 and 45.30 meters. The elevated portion of the split-level JFD is based on wind speeds and direction measurements at the 45.74 meter level and the vertical temperature difference between 10.03 and 89.59 meters. Both of these JFDs are given for each quarter in the 2012 Meteorological Data Tables 8A, 8B, 8C, and 8D.
Releases from the stack are considered to be elevated releases. The JFDs for elevated releases are based on wind directions and wind speeds measured at 90.29 meters and the vertical temperature difference between 10.03 and 89.59 meters, and are given for each quarter in the 2012 Meteorological Data Tables 9A, 9B, 9C, 9D.
- b. Meteorological Data Meteorological variables at BFN are measured continuously. Measurements collected include wind speed and wind direction at heights of 10.5, 45.74, and 90.29 meters above the ground, and temperature at heights of 10.03, 45.30, and 89.59 meters above the ground. Quarterly JFDs are calculated for each release point using the appropriate levels of meteorological data. A quarterly JFD gives the percentage of the time that the wind is blowing out of a particular upwind compass sector in a particular range of wind speeds for a given stability class A through G. The wind speeds are divided into nine wind speed ranges. Calms are distributed by direction in proportion to the distribution of noncalm wind directions less than 1.6 m/s (3.5 mph). Stability classes are determined from the vertical temperature difference between two measurement levels.
The generally open terrain around BFN does not cause any significant effects on the transport and dispersion of gaseous effluents from the plant. Within 30 kilometers of BFN, the terrain is mostly gently rolling hills (30-60 meters). Between 30 and 80 kilometers, the hills become larger to the north and south and mountainous to the east and northeast. The Tennessee River/Wheeler Lake may have a minor effect on transport and dispersion in the immediate vicinity of BFN during periods of winds with a southerly component, overcast skies, and relatively high wind speeds. Also, the lower layer (10-45 meters) stability class tends to be more stable. However, during this infrequent condition, dose estimates will be conservative.
E-35
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT RADIOLOGICAL IMPACT
- 4. Doses From Airborne Effluents (Continued)
- c. External Exposure Dose Dose calculated for maximum external air dose (gamma-air and beta-air) are made for points at and beyond the unrestricted area boundary as described in the BFN ODCM. The highest of these doses is then selected.
- d. Submersion Dose External doses to the skin and total body, due to submersion in a cloud of noble gases, are calculated for the nearest residence in each sector. The residence with the highest dose is then selected from all sectors.
- e. Organ Dose Dose to an organ due to releases of airborne effluents are estimated for the inhalation, ground contamination, and ingestion pathways. The ingestion pathway is further divided into three possible contributing pathways: ingestion of cow/goat milk, ingestion of beef, and ingestion of vegetables. Doses from applicable pathways are calculated for each receptor location identified in the most recent land use survey. To determine the maximum organ dose, the doses from the pathways are summed for each receptor. However, for the ingestion dose, only those pathways that exist for each receptor are considered in the sum, e.g., milk ingestion doses are included only for locations where milk was consumed without commercial preparation and vegetable ingestion is included only for those locations where a garden was identified. To conservatively account for beef ingestion, a beef ingestion dose equal to that for the highest unrestricted area boundary location is added to each identified receptor. For ground contamination, the dose added to the organ dose being calculated is the total body dose calculated for that location, i.e., it is assumed that the dose to an individual organ is equal to the total body dose.
The maximum organ dose, thyroid dose, and total body dose from airborne effluents are presented in Table 4.
- 5. Doses From Airborne Effluents For liquid effluents, the public can be exposed to radiation from three sources: the ingestion of water from the Tennessee River, the ingestion of fish caught in the Tennessee River, and direct exposure from radioactive material deposited on the river shoreline sediment (recreation).
The concentration of radionuclides in the Tennessee River is calculated by a computer model which uses measured hydraulic data downstream of BFN. Parameters used to determine the doses are based on guidance given by the NRC for maximum ingestion rates, exposure times, etc.
E-36
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT RADIOLOGICAL IMPACT
- 5. Doses From Airborne Effluents (Continued)
Wherever possible, parameters used in the dose calculation are site specific. The models that are used to estimate doses, as well as the parameters input to the models, are described in detail in the BFN ODCM.
- a. Liquid Release Points and River Data Radionuclide concentrations in the Tennessee River are calculated assuming that releases in liquid effluents are continuous. When necessary, liquid releases from BFN, located at Tennessee River Mile 294, are made through diffusers which extend into the Tennessee River. It is assumed that releases to the river through these diffusers will initially be entrained in one-fifth of the water which flows past the plant. The QWATA code makes the assumption that this mixing condition holds true until the water is completely mixed at the first downstream dam (Wheeler Dam), at Tennessee River Mile 283.
Doses are calculated for locations within a 50 mile radius downstream of the plant site.
The maximum potential recreation dose is calculated for a location immediately downstream from the plant's release point. The maximum exposed individual dose from ingestion of fish is assumed to be that calculated for the consumption of fish caught anywhere between the plant and the first downstream dam. The maximum exposed individual dose from drinking water is assumed to be that calculated at the nearest downstream public water supply [West Morgan - East Lawrence (WMEL)]. This could be interpreted as indicating that the maximum exposed individual, as assumed for liquid releases from BFN, is an individual who obtains all of his drinking water at WMEL, consumes fish caught from the Tennessee River between BFN and Wheeler Dam, and spends 500 hours0.00579 days <br />0.139 hours <br />8.267196e-4 weeks <br />1.9025e-4 months <br /> per year on the shoreline just downstream of the plant's release point.
Doses calculated for the maximum exposed individual due to liquid effluents for each quarter in the period are presented in Table 5 along with the average river flows past the plant site for the periods.
- 6. Population Doses Population doses due to airborne effluents are calculated for an estimated 778,266 people living within a 50-mile radius of the plant site. Doses from external pathways and inhalation are based on the 50-mile human population distribution. Ingestion population doses are calculated assuming that each individual consumed milk, vegetables, and meat produced within the sector in which the individual resides.
Population doses due to liquid effluents are calculated for the entire downstream Tennessee River population. Water ingestion population doses are calculated using actual population figures for downstream public water supplies. Fish ingestion population doses are calculated assuming that all sport fish caught in the Tennessee River are consumed by the Tennessee River population. Recreation population doses are calculated using historical recreational data on the number of shoreline visits at downstream locations.
E-37
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT RADIOLOGICAL IMPACT
- 6. Population Doses (Continued)
Population doses calculated for airborne and liquid effluents are presented in Tables 4 and 5
- 7. Offsite Direct Radiation Dose External gamma radiation levels were measured by environmental dosimeters deployed around BFN as part of the offsite Radiological Environmental Monitoring Program (REMP).
The quarterly gamma radiation levels determined from these dosimeters during this reporting period averaged approximately 18 mrem/quarter at onsite (at or near the site boundary) stations and approximately 15 mrem/quarter at offsite stations or approximately 2.5 mrem/quarter higher onsite than at offsite stations. This difference is consistent with levels measured for pre-operation and construction phases of the Tennessee Valley Authority nuclear plants where the average radiation levels onsite were generally 2-6 mrem/quarter higher than the levels offsite. This may be attributable to natural variations in environmental radiation levels, earth moving activities onsite, the mass of concrete employed in the construction of the plants, or other undetermined influences.
Fluctuations in natural background dose rates and in dosimeter readings tend to mask any small increments which may be due to plant operations. Thus, there was no identifiable increase in dose rate levels attributable to direct radiation from plant equipment and/or gaseous effluents.
- 8. Dose To A Member Of The Public Inside The Site Boundary Pursuant to ODCM Section 7.7.5, a review was performed to determine the highest dose to a member of the public in the site boundary. The dose to a member of the public consists of the sum of dose commitments from effluent releases as well as any direct radiation dose.
The gaseous effluent dose commitment is negligible compared to the direct radiation dose.
The direct radiation dose was determined from area environmental dosimeters located onsite. It consisted of gamma dose from the plume, ground contamination, and from equipment sources (i.e., tanks, turbine shine, radioactive material storage areas, etc.). The critical location was determined to be a Thermoluminescent Dosimeter near the Livewell Center (Training Center). The direct radiation dose accounting for background and occupancy was 0.63 mrem during 2012.
The total annual dose commitment to a member of the public for 2012 is 0.63 mrem. It can be concluded that the dose limit for a member of the public at the site boundary as specified in 10 CFR 20.1301 was not exceeded.
E-38
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT RADIOLOGICAL IMPACT
- 9. Total Dose To determine compliance with 40 CFR 190, annual total dose contributions to the maximum exposed individual from BFN radioactive effluents and all other nearby uranium fuel cycle sources are considered.
The annual dose to any organ other than the thyroid for the maximum exposed individual is conservatively calculated by summing the following doses: the total body air submersion dose for each quarter, the critical organ dose (for any organ other than the thyroid) from airborne effluents for each quarter from ground contamination, inhalation and ingestion, the total body dose from liquid effluents for each quarter, the maximum organ dose (for any organ other than the thyroid) from liquid effluents for each quarter, and any identifiable increase in direct radiation dose levels as measured by the REMP. This dose is compared to the 40 CFR 190 limit for total body or any organ dose (other than the thyroid) to determine compliance.
The annual thyroid dose to the maximum exposed individual is conservatively estimated by summing the following doses: the total body air submersion dose for each quarter, the thyroid dose from airborne effluents for each quarter, the total body dose from liquid effluents for each quarter, the thyroid dose from liquid effluents for each quarter, and any identifiable increase in direct radiation dose levels as measured by the REMP. This dose is compared to the 40 CFR 190 limit for thyroid dose to determine compliance.
Total dose from the fuel cycle is presented in Table 6.
E-39
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT RADIOLOGICAL IMPACT TABLE 4 Page 1 of 4 Doses from Airborne Effluents First Quarter Individual Doses Pathway Dose Quarterly Percent of Location Limit Limit External Gamma Air 8.7E-10 mrad 5 mrad
< 1 %
NNW/1650 meters Beta Air 2.7E-09 mrad 10 mrad
< 1 %
NNW/1650 meters Submersion Total Body 1.4E-04 mrem NA NA NNW/1650 meters Skin 1.6E-04 mrem NA NA NNW/1650 meters Organ Doses Child/Bone 1.2E-01 mrem 7.5 mrem 1.6%
NNW 1790 meters Child/Thyroid 1.3E-01 mrem 7.5 mrem 1.7%
NNW 1790 meters Child/Total 1.1E-01 mrem 7.5 rnrem 1.5 %
NNW 1790 meters Body LL L
Population Doses Total Body Dose 3.3E-01 man-rem Maximum Organ Dose (organ) 3.6E-01 man-rem (thyroid)
Population doses can be compared to the natural background dosefbr the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).
E-40
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT RADIOLOGICAL IMPACT TABLE 4 (Continued)
Page 2 of 4 Doses from Airborne Effluents Second Quarter*
Individual Doses Pathway Dose Quarterly Percent of Location Limit Limit External Gamma Air 1.8E-10 mrad 5 mrad
< 1 %
NW/2275 meters Beta Air 3.5E-10 mrad 10 mrad
< 1 %
S/2250 meters Submersion Total Body 9.3E-04 mrem NA NA NNW/1650 meters Skin 1.1E-03 mrem NA NA NNW/1650 meters Organ Doses Child/Bone 3.OE-02 mrem 7.5 mrem
< 1 %
NNW/1790 meters Child/Thyroid 1.7E-02 mrem 7.5 mrem
< 1%
NNW/1790 meters Child/Total 1.2E-02 mrem 7.5 inrem
< 1 %
NNW/1790 meters Body I
I Population Doses Total Body Dose 1.3E-01 man-rem Maximum Organ Dose (organ) 5. 1E-01 man-rem (bone)
Population doses can be compared to the natural background dosejbr the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).
- Includes dose from abnormal releases.
E-41
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT RADIOLOGICAL IMPACT TABLE 4 (Continued)
Page 3 of 4 Doses from Airborne Effluents Third Quarter Individual Doses Pathway Dose Quarterly Percent of Location Limit Limit External Gamma Air 2.6-06 mrad 5 mrad
< 1 %
N/4900 meters Beta Air 4.1 E-06 mrad 10 mrad
< 1 %
N/4900 meters Submersion Total Body 1.4E-03 mrem NA NA E/1410 meters Skin 1.6E-03 mrem NA NA E/1410 meters Organ Doses Child/Bone 3.4E-02 unrem 7.5 mrem
< 1%
E/1410 meters Child/Thyroid 2.1E-02 mrem 7.5 mrem
< 1%
E/1410 meters Child/Total 1.3E-02 mrem 7.5 mrem
< 1 %
NNW/1790 meters Body Population Doses Total Body Dose 1.8E-01 man-rem Maximum Organ Dose (organ) 7.6E-01 man-rem (bone)
Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/vr for natural background).
E-42
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT RADIOLOGICAL IMPACT TABLE 4 (Continued)
Page 4 of 4 Doses from Airborne Effluents Fourth Quarter*
Individual Doses Pathway Dose Quarterly Percent of Location Limit Limit External Gamma Air 2.6E-10 mrad 5 mrad
< 1 %
S/2250 meters Beta Air 7.9E-10 mrad 10 mrad
< 1 %
S/2250 meters Submersion Total Body 6.9E-4 mrem NA NA ESE/1750 meters Skin 8.1E-04 mrem NA NA ESE/1750 meters Organ Doses Child/ Bone 2.2E-02 mrem 7.5 mrem
< 1%
N/2540 meters Child/Thyroid 1.3E-02 mrem 7.5 mrem
< 1%
NNW/1790 meters Child /Total 9.4E-03 mrem 7.5 mrem
< 1 %
NNW/1790 meters Body I
Population Doses Total Body Dose 1.2E-01 man-rem Maximum Organ Dose (organ) 4.6E-01 man-rem (bone)
Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/yr for natural background).
- Includes dose from abnormal releases.
E-43
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT RADIOLOGICAL IMPACT Table 5 Page 1 of 4 Doses from Liquid Effluents First Quarter Individual Doses (mrem)
Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Adult Total Body Fish Ingestion 9.OE-05 Recreation 1.3E-05 Water Ingestion 7.1 E-06 Total 1.1E-04 1.5 mrem
< 1 %
Adult Liver Fish Ingestion 1.4E-04 Recreation 1.3E-05 Water Ingestion 7.9E-06 Total 6.1E-05 5 mrem
< 1 %
Child Thyroid Fish Ingestion 9.OE-08 Recreation 1.3E-05 Water Ingestion 7.3E-06 Total 2.OE-05 5 mrem
< 1 %
Average Riverflow past BFN (cubic feet per second): 74339 Population Doses Total Body Dose 8.1 E-04 man-rem Maximum Organ Dose (organ) 1.3E-03 man-rem (liver)
Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mrem/vr for natural background).
E-44
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT RADIOLOGICAL IMPACT Table 5 (Continued)
Page 2 of 4 Doses from Liquid Effluents Second Quarter Individual Doses (mrem)
Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Child Total Body Fish Ingestion 5.9E-07 Recreation O.OE+00 Water Ingestion 4.7E-05 Total 4.8E-05 1.5 mrem
< 1 %
Child Liver**
Fish Ingestion 5.9E3-07 Recreation O.OE+00 Water Ingestion 4.7E-05 Total 4.8E-05 5 mrem
< 1 %
Child Thyroid Fish Ingestion 5.9E-07 Recreation O.OE+00 Water Ingestion 4.7E-05 Total 4.8E-05 5 mrem
< 1 %
Average Riverflow past BFN (cubic feet per second): 13255 Population Doses Total Body Dose 8.1E-04 man-rem Maximum Organ Dose (organ) 8.1E-04 man-rem (liver**)
Population doses can be compared to the natural background dose for the entire 50-mile population of" about 70,044 man-rein/year (based on 90 mrern/yr for natural background).
- Includes dose from abnormal releases.
- All organ doses are equal.
E-45
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT RADIOLOGICAL IMPACT Table 5 (Continued)
Page 3 of 4 Doses from Liquid Effluents Third Quarter*
Individual Doses (mrem)
Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Child Total Body Fish Ingestion 1.5E-07 Recreation O.OE+00 Water Ingestion 1.2E-05 Total 1.2E-05 1.5 mrem
< 1 %
Child Liver**
Fish Ingestion 1.5E-07 Recreation O.OE+00 Water Ingestion 1.2E-05 Total 1.2E-05 5 mrem
< 1 %
Child Thyroid Fish Ingestion 1.5E-07 Recreation 0.0E+00 Water Ingestion 1.2E-05 Total 1.2E-05 5 mrem
< 1%
Average Riverflow past BFN (cubic feet per second): 27679 Population Doses Total Body Dose 2.0E-04 man-rem Maximum Organ Dose (organ) 2.OE-04 man-rem (liver**)
Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rem/year (based on 90 mren/vr for natural background).
- Includes dose from abnormal releases.
- All organ doses are equal.
E-46
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT RADIOLOGICAL IMPACT Table 5 (Continued)
Page 4 of 4 Doses from Liquid Effluents Fourth Quarter*
Individual Doses (mrem)
Age Group Organ Dose Pathway Dose Quarterly Percent of Limit Limit Child Total Body Fish Ingestion 7.4E-07 Recreation O.OE+00 Water Ingestion 6.OE-05 Total 6.1E-05 1.5 mrem
< 1 %
Child Liver**
Fish Ingestion 7.4E-07 Recreation O.OE+00 Water Ingestion 6.OE-05 Total 6.1E-05 5 mrem
< 1 %
Child Thyroid Fish Ingestion 7.4E-07 Recreation O.OE+00 Water Ingestion 6.OE-05 Total 6.1E-05 5 mrem
< 1%
Average Riverflow past BFN (cubic feet per second): 36693 Population Doses Total Body Dose 9.8E-04 man-rem Maximum Organ Dose (organ) 9.8E-04 man-rem (liver**)
Population doses can be compared to the natural background dose for the entire 50-mile population of about 70,044 man-rein/year (based on 90 mrem/yr for natural background).
- Includes dose from abnormal releases.
E-47
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT RADIOLOGICAL IMPACT Table 6 Page 1 of 1 Total Dose from Fuel Cycle First Second Third Fourth Dose Quarter Quarter Quarter Quarter Total Body or any Organ (except thyroid)
Total body air submersion 1.4E-04 9.3E-04 1.4E-03 6.9E-04 Critical organ dose (air) 1.2E-01 3.OE-02 3.4E-02 2.2E-02 Total body dose (liquid) 1.1E-04 4.8E-05 1.2E-05 6.1E-05 Maximum organ dose (liquid) 6.1E-05 4.8E-05 1.2E-05 6.1E-05 Direct Radiation Dose O.OE+00 O.OE+00 O.OE+00 O.OE+00 Total 1.2E-01 3.1 E-02 3.5E-02 2.3E-02 Cumulative Total Dose 2.1 E-01 (mrem)
(Total body or any other organ)
Annual Dose Limit (mrem) 2.5E+01 Percent of Limit
< 1%
Thyroid Dose (mrem)
Total body air submersion 1.4E-04 9.3E-04 1.4E-03 6.9E-04 Thyroid dose (airborne) 1.3E-01 1.7E-02 2.1E-02 1.3E-02 Total body dose (liquid) 1.1E-04 4.8E-05 1.2E-05 6.1E-05 Thyroid dose (liquid) 2.OE-05 4.8E-05 1.2E-05 6.1E-05 Direct Radiation Dose O.OE+00 O.OE+00 O.OE+00 O.OE+00 Total 1.3E-01 1.8E-02 2.2E-02 1.4E-02 Cumulative Total Dose (Thyroid) mrem 1.8E-01 Annual Dose Limit (mrem) 7.5E+01 Percent of Limit
< 1%
E-48
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT BROWNS FERRY NUCLEAR PLANT 2012 METEOROLOGICAL DATA TABLE 7A JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES FIRST QUARTER E-49
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2012 -
MAR 31, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.238 0.238 0.190 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.714 0.000 0.000 0.000 0.000 0.000 0.143 0.571 0.571 0.523 0.238 0.190 0.000 0.000 0.000 0.000 0.000 2.236 0.000 0.000 0.000 0.000 0.000 0.000 0.190 0.000 0.000 0.095 0.143 0.095 0.000 0.048 0.048 0.000 0.618 0.143 0.048 0.048 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.048 0.095 0.048 0.000 0.095 0.618 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.048 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.143 0.048 0.048 0.000 0.048 0.143 1.094 0.809 0.714 0.333 0.333 0.143 0.095 0.143 0.095 0.143 4.329 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2107 91 91 2102 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2012/05/15 MEAN WIND SPEED =
5.48 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-50
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2012 -
MAR 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.143 0.000 0.000 0.095 0.048 0.000 0.000 0.000 0.000 0.000 0.285 0.048 0.000 0.000 0.000 0.000 0.048 0.428 0.143 0.190 0.048 0.095 0.095 0.000 0.000 0.000 0.000 1.094 0.000 0.048 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.048 0.048 0.000 0.048 0.000 0.285 0.000 0.000 0.048 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.143 0.048 0.000 0.048 0.333 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.190 0.095 0.143 0.428 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.048
>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.048 0.048 0.000 0.000 0.095 0.666 0.143 0.190 0.143 0.143 0.143 0.190 0.238 0.190 0.190 2.474 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2107 52 52 2102 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =
7.06 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/05/15 E-51
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2012 -
MAR 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.143 0.095 0.095 0.048 0.048 0.000 0.000 0.000 0.000 0.000 0.476 0.048 0.000 0.000 0.000 0.000 0.048 0.285 0.095
- 0. 190 0.048 0.048 0.095 0.000 0.048 0.000 0.000 0.904 0.095 0.143 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.048 0.000 0.428 0.190 0.190 0.095 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.143 0.285 0.238 0.190 1.475 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.285 0.048 0.238 0.571 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.095 0.000 0.143 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.333 0.333 0.095 0.000 0.048 0.095 0.476 0.190 0.285 0.095 0.095 0.190 0.238 0.666 0.428 0.428 3.996 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2107 85 84 2102 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2012/05/15 MEAN WIND SPEED =
8.35 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-52
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2012 -
MAR 31, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.048 0.095 0.095 0.143 0.048 0.000 0.190 0.381 0.523 0.618 0.428 0.190 0.238 0.095 0.143 0.048 0.190 3.425 0.714 0.428 0.428 0.333 0.285 0.333 0.714 0.190 0.238 0.285 0.095 0.428 0.333 0.143 0.381 0.381 5.709 0.333 0.381 0.285 0.285 0.000 0.285 0.333 0.048 0.095 0.048 0.000 0.523 0.238 0.761 0.381 0.523 4.520 0.333 0.523 0.143 0.143 0.000 0.000 0.000 0.048 0.000 0.048 0.048 0.285 1.094
- 0. 951 1.475 1.284 6.375 0.143 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.190 0.904 0.714 0.523 2.569 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.143 0.095 0.095 0.333 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.618 1.522 0.999 0.809 0.285 0.809 1.427 0.809 0.951 0.809 0.333 1.522 1.951 3.045 3.092 2.997 0.000 22.978 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2107 485 483 2102 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =
7.34 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/05/15 E-53
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2012 -
MAR 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4
>=24.5 TOTAL 0.000 0.048 0.000 0.190 0.095 0.143 0.143 0.333 0.238 0.048 0.095 0.048 0.048 0.000 0.048 0.000 0.856 0.761 0.714 0.333 0.951 1.047 1.332 2.093 0.904 0.714 0.571 0.571 0.428 0.190 0.381 0.285 0.428 0.761 0.333 0.714 0.285 2.236 1.094 0.428 1.237 0.571 0.095 0.381 0.809 0.333 0.714 0.618 11.037 0.381 0.476 0.381 0.095 0.000 0.714 0.381 0.000 0.714 0.618 0.048 0.190 0.190 0.095 0.571 0.523 5.376 0.143 0.143 0.095 0.000 0.000 0.143 0.190 0.095 0.571 0.714 0.048 0.095 0.285 0.190 1.475 0.714 4.900 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.095 0.618 0.333 1.142 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.855 2.188 1.522 1.332 1.332 4.282 3.140 2.950 3.663 2.664 0.856 1.284 1.808 0.904 3.806 2.474 1.475 12.131 0.000 36.061 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2107 759 758 2102 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =
4.90 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/05/15 E-54
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2012 -
MAR 31, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.048 0.190 0.143 0.381 0.333 0.190 0.238 0.048 0.048 0.048 0.000 0.000 0.000 0.000 0.904 0.571 0.476 0.476 0.571 0.428 1.713 2.617 1.665 0.285 0.238 0.190 0.190 0.190 0.285 0.714 0.571 0.571 0.143 0.143 0.761 0.428 0.428 0.381 0.761 0.333 0.048 0.048 0.000 0.000 0.095 0.523 5.233 0.000 0.333 0.048 0.000 0.000 0.000 0.095 0.000 0.714 0.285 0.000 0.000 0.000 0.000 0.000 0.143 1.618 0.048 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.285 0.285 0.000 0.000 0.048 0.000 0.000 0.000 0.714 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.522 1.618 0.714 0.809 1.475 1.237 2.569 3.187 3.663 1.237 0.333 0.285 0.238 0.190 0.381 1.380 SUBTOTAL 1.713 11.513 0.000 20.837 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2107 438 438 2102 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =
3.32 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/05/15 E-55
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2012 -
MAR 31, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.005 0.003 0.001 0.002 0.002 0.004 0.006 0.015 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.048 0.238 0.095 0.190 0.095 0.238 0.428 0.523 0.571 0.285 0.000 0.000 0.048 0.000 0.000 0.000 0.095 2.807 0.618 0.381 0.048 0.238 0.048 0.285 0.428 2.046 0.904 0.048 0.048 0.000 0.000 0.000 0.000 0.143 5.233 0.428 0.048 0.095 0.000 0.000 0.000 0.000 0.143 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.856 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.190 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.238 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.290 0.764 0.477 0.335 0.287 0.718 0.957 2.775 1.292 0.048 0.048 0.048 0.000 0.000 0.000 0.287 9.324 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2107 197 196 2102 1
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2012/05/15 MEAN WIND SPEED =
2.31 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-56
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT BROWNS FERRY NUCLEAR PLANT 2012 METEOROLOGICAL DATA TABLE 7B JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES SECOND QUARTER E-57
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2012 -
JUN 30, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.138 0.780 1.422 1.743 0.780 0.046 0.000 0.000 0.000 0.000 0.000 5.000 0.000 0.000 0.000 0.046 0.000 0.459 1.835 1.284 0.734 0.642 0.550 0.505 0.550 0.092 0.000 0.000 6.697 0.275 0.275 0.046 0.000 0.000 0.183 0.000 0.000 0.000 0.000 0.000 0.092 0.092 0.183 0.092 0.229 1.468 0.505 0.550 0.229 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.092 0.367 0.688 2.523 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.413 0.229
- 0. 688 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000, 0.000 0.780 0.826 0.275 0.092 0.046 0.780 2.615 2.706 2.477 1.422 0.596 0.596 0.734 0.413 0.872 1.147 0.000 16.376 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2180 357 357 2180 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2012/08/20 MEAN WIND SPEED 5.34 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-58
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2012 -
JUN 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.275 0.367 0.367 0.275 0.092 0.046 0.046 0.000 0.000 0.000 1.514 0.000 0.000 0.046 0.000 0.000 0.459 0.092 0.046 0.138 0.138 0.092 0.183 0.138 0.138 0.000 0.000 1.468 0.229 0.138 0.138 0.092 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.092 0.046 0.138 0.183 0.000 1.101 0.321 0.138 0.138 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.229 0.183 1.101 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.138 0.046 0.183 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.596 0.275 0.321 0.092 0.000 0.505 0.367 0.413 0.505 0.413 0.183 0.321 0.229 0.367 0.550 0.229 5.367 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2180 117 117 2180 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =
5.65 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/08/20 E-59
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2012 -
JUN 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.046 0.459 0.321 0.505 0.229 0.275 0.138 0.092 0.000 0.000 0.000 2.156 0.183 0.046 0.046 0.046 0.046 0.229 0.046 0.000 0.092 0.138 0.046 0.138 0.183 0.092 0.000 0.092 1.422 0.092 0.138 0.000 0.046 0.046 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.092 0.092 0.046 0.688 0.092 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.229 0.138 0.183 0.734 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.138 0.000 0.138 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.367 0.275 0.092 0.092 0.138 0.367 0.505 0.321 0.596 0.367 0.321 0.275 0.321 0.413 0.367 0.321 5.138 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2180 112 112 2180 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2012/08/20 MEAN WIND SPEED =
4.92 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-60
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2012 -
JUN 30, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.092 0.000 0.046 0.000 0.046 0.092 0.000 0.046 0.000 0.000 0.000 0.367 0.092 0.092 0.183 0.046 0.275 0.780 0.826 1.284 0.550 0.780 0.596 1.101 0.413 0.229 0.138 0.275 7.661 0.642 0.505 0.183 0.000 0.642 1.284 0.000 0.092 0.092 0.321 0.183 0.321 0.872 0.550 0.596 0.734 7.018 0.734 0.367 0.367 0.138 0.092 0.092 0.000 0.000 0.000 0.000 0.000 0.229 0.459 0.780 0.642 0.688 4.587 0.459 0.275 0.046 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.229 1.101 0.963 0.780 3.945 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.046 0.183 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.972 1.239 0.780 0.183 1.055 2.294 0.826 1.422 0.642 1.147 0.872 1.697 2.018 2.661 2.431 2.523 0.000 23.761 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2180 518 518 2180 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2012/08/20 MEAN WIND SPEED =
5.00 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-61
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2012 -
JUN 30, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.138 0.183 0.229 0.275 0.229 0.275 0.138 0.092 0.046 0.000 0.000 0.046 0.092 0.000 1.284 0.596 0.275 0.688 1.606 1.284 0.642 0.963 1.376 1.376 0.459 0.734 0.917 0.413 0.046 0.642 0.459 0.688 0.321 0.183 0.917 1.055 0.000 0.000 0.046 0.321 0.046 0.046 0.917 0.229 0.275 0.917 6.422 0.413 0.550 0.275 0.000 0.092 0.275 0.000 0.000 0.000 0.000 0.000 0.046 0.275 0.092 0.138 0.183 2.339 0.092 0.367 0.183 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.183 0.367 1.330 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.294 2.248 1.193 1.055 2.844 2.936 0.872 1.239 1.560 1.789 0.550 0.826 2.156 0.826 0.734 2.110 SUBTOTAL 1.835 13.303 0.000 25.229 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2180 550 550 2180 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =
3.50 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/08/20 E-62
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2012 -
JUN 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 TOTAL 0.183 0.000 0.367 0.550 0.367 0.183 0.138 0.138 0.046 0.046 0.092 0.092 0.046 0.046 0.092 0.275 2.661 1.422 0.963 0.688 0.826 1.284 0.688 0.229 0.183 0.138 0.092 0.138 0.505 0.229 0.138 0.092 0.505 8.119 0.550 0.963 0.275 0.138 0.459 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.183 0.000 0.000 0.138 2.752 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.138 0.229 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.202 1.972 1.330 1.514 2.110 0.917 0.367 0.321 0.183 0.138 0.229 0.596 0.459 0.183 0.183 1.055 0.000 13.761 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2180 300 300 2180 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =
2.52 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/08/20 E-63
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2012 -
JUN 30, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.016 0.007 0.006 0.005 0.002 0.001 0.000 0.001 0.000 0.001 0.000 0.000 0.000 0.000 0.001 0.005 0.046 1.284 0.321 0.596 0.275 0.275 0.138 0.046 0.046 0.092 0.092 0.000 0.046 0.000 0.000 0.183 0.413 3.807 1.881 1.009 0.688 0.688 0.183 0.000 0.000 0.138 0.000 0.046 0.000 0.000 0.000 0.000 0.046 0.596 5.275 0.734 0.275 0.046 0.046 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 1.239 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 3.915 1.612 1.337 1.014 0.553 0.138 0.046 0.184 0.092 0.138 0.000 0.046 0.000 0.046 0.231 1.014 0.000 10.367 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G 2180 226 226 2180 TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2012/08/20 MEAN WIND SPEED =
2.00 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-64
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT BROWNS FERRY NUCLEAR PLANT 2012 METEOROLOGICAL DATA TABLE 7C JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES THIRD QUARTER E-65
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT JUL 1, 2012 -
SEP 30, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.106 0.797 1.328 1.168 1.753 0.372 0.000 0.053 0.000 0.000 0.000 5.629 0.000 0.000 0.000 0.000 0.000 0.690 0.903 0.584 0.478 0.850 0.637 0.584 0.690 0.159 0.000 0.000 5.576 0.053 0.000 0.053 0.000 0.000 0.053 0.000 0.000 0.000 0.000 0.000 0.053 0.903 0.106 0.053 0.053 1.328 0.053 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.266 0.584 0.159 0.106 1.168 0.000 0.000 0.053 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.106 0.159 0.053 0.372 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.106 0.000 0.106 0.000 0.053 0.850 1.699 1.912 1.646 2.602 1.009 0.637 1.912 0.956 0.372 0.212 0.000 14.073 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 1884 266 265 1883 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2012/11/19 MEAN WIND SPEED =
4.56 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-66
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT JUL 1, 2012 -
SEP 30, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.106 0.372 0.956 0.319 0.797 0.159 0.159 0.000 0.000 0.000 0.000 2.921 0.053 0.053 0.053 0.106 0.000 0.266 0.053 0.053 0.000 0.053 0.212 0.266 0.478 0.053 0.000 0.159 1.859 0.159 0.159 0.053 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.319 0.266 0.106 0.106 1.168 0.106 0.106 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.053 0.425 0.159 0.903 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.000 0.053 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.319 0.319 0.106 0.106 0.053 0.372 0.425 1.009 0.319 0.850 0.372 0.425 0.850 0.372 0.584 0.425 6.904 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 1884 130 130 1883 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2012/11/19 MEAN WIND SPEED =
4.75 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-67
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JUL 1, 2012 -
SEP 30, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.000 0.000 0.000 0.053 0.266 0.478
- 0. 637 0.531 0.319 0.106 0.159 0.000 0.000 0.000 2.602 0.159 0.053 0.000 0.000 0.053 0.053 0.053 0.000 0.053 0.053 0.053 0.159 0.637 0.106 0.266 0.053 1.753 0.212 0.053 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.159 0.266 0.159 0.106 0.956 0.000 0.000 0.053 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.053 0.212 0.053 0.425 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.372 0.159 0.053 0.000 0.053 0.106 0.319 0.478
- 0. 690 0.584 0.372 0.266 1.009 0.425 0.637 0.212 5.736 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 1884 108 108 1883 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2012/11/19 MEAN WIND SPEED 4.38 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-68
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JUL 1, 2012 -
SEP 30, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.000 0.053 0.053 0.106 0.000 0.053 0.000 0.000 0.000 0.266 0.319 0.478 0.159 0.319 1.540 1.593 1.381 2.602 2.921 1.328 1.328 0.266 0.106 0.212 0.266 0.425 0.372 0.743 0.478 0.743 1.699 0.319 0.053 0.053 0.159 0.000 0.956 1.328 0.478 0.053 0.319 8.178 0.106 0.319 0.106 0.000 0.319 0.690 0.000 0.000 0.000 0.000 0.053 0.000 0.478 0.266 0.053 0.319 2.708 0.000 0.053 0.053 0.106 0.053 0.159 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.212 0.266 0.212 1.168 0.000 0.053 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.797 1.115 1.381 0.743 1.434 4.089 1.965 1.434 2.708 3.133 1.487 2.284 2.177 1.062 0.584 1.115 SUBTOTAL 0.319 15.082 0.000 27.509 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 1884 518 518 1883 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 1-0.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =
3.68 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/11/19 E-69
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JUL 1, 2012 -
SEP 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4
>=24.5 TOTAL 0.053 0.053 0.053 0.159 0.425 0.212 0.425 0.106 0.637 0.319 0.212 0.159 0.000 0.106 0.000 0.000 0.850 0.584 0.850 1.009 1.806 1.434 0.743 0.797 1.275 1.646 0.956 1.062 1.062 0.319 0.106 0.319 0.584 0.478 0.425 0.690 1.699 0.637 0.000 0.053 0.000 0.000 0.000 0.372
- 0. 690 0.266 0.266 0.584 6.745 0.000 0.319 0.106 0.053 0.053 0.053 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.106 0.106 0.797 0.000 0.159 0.159 0.000 0.053 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.106 0.053 0.584 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.487 1.593 1.593 1.912 4.036 2.337 1.168 0.956 1.912 1.965 1.168 1.593 1.753 0.743 0.584 1.062 2.921 14.817 0.000 25.863 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 1884 487 487 1883 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2012/11/19 MEAN WIND SPEED =
3.02 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-70
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT JUL 1, 2012 -
SEP 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL CALM 0.008 0.008 0.007 0.010 0.009 0.004 0.000 0.001 0.001 0.001 0.001 0.000 0.000 0.000 0.001 0.002 0.053 0.319 0.425 0.266 0.159 0.212 0.159 0.000 0.053 0.000 0.053 0.000 0.000 0.000 0.000 0.106 0.000 1.753 0.850 0.743 0.797 1.434 1.168 0.425 0.000 0.106 0.159 0.159 0.159 0.000 0.000 0.000 0.106 0.372 6.479 0.266 0.266 0.212 0.531 0.690 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.000 0.000 0.319 2.337 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.441 1.441 1.335 2.135 2.080 0.588 0.000 0.160 0.160 0.214 0.160 0.000 0.053 0.000 0.214 0.693 0.000 10.674 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 1884 201 201 1883 1
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2012/11/19 MEAN WIND SPEED 2.62 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-71
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT JUL 1, 2012 -
SEP 30, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.584 0.743 0.319 0.159 0.053 0.053 0.000 0.053 0.053 0.053 0.053 0.000 0.000 0.053 0.106 0.797 3.080 1.115 0.743 0.743 0.584 0.319 0.000 0.053 0.159 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.743 4.461 1.062 0.106 0.053 0.212 0.106 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.106 1.646 0.000 0.000 0.000 0.053 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.762 1.593 1.115 1.009 0.478 0.053 0.053 0.212 0.053 0.053 0.053 0.000 0.000 0.053 0.106 1.646 9.241 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 1884 174 174 1883 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2012/11/19 MEAN WIND SPEED 2.19 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-72
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT BROWNS FERRY NUCLEAR PLANT 2012 METEOROLOGICAL DATA TABLE 7D JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR GROUND LEVEL RELEASES FOURTH QUARTER E-73
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2012 -
DEC 31, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.379 0.568 0.284 0.000 0.000 0.000 0.000 0.000 0.000 1.326 0.000 0.000 0.000 0.047 0.237 0.332 0.332 0.047 0.189 0.237 0.000 0.000 0.000 0.000 0.000 0.000 1.421 0.142 0.000 0.000 0.332 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.474 0.142 0.189 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.095 0.000 0.047 0.047 0.568 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.284 0.189 0.000 0.379 0.237 0.332 0.426 0.426 0.758 0.521 0.000 0.047 0.095 0.047 0.142 0.047 3.932 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2111 83 83 2111 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2013/02/06 MEAN WIND SPEED =
5.32 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-74
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2012 -
DEC 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.284 0.189 0.095 0.189 0.047 0.000 0.000 0.000 0.000 0.000 0.900 0.000 0.000 0.000 0.047 0.095 0.237 0.000 0.000 0.047 0.142 0.000 0.095 0.047 0.000 0.000 0.000 0.711 0.000 0.284 0.000 0.047 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.426 0.142 0.189 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.095 0.379 0.047 0.947 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.189 0.000 0.332 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.047 0.000 0.142 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.142 0.521 0.095 0.095 0.142 0.332 0.284 0.189 0.142 0.332 0.047 0.142 0.047 0.284 0.616 0.047 3.458 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2111 73 73 2111 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2013/02/06 MEAN WIND SPEED =
7.21 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-75
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2012 -
DEC 31, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.095 0.426 0.568 0.142 0.095 0.095 0.000 0.047 0.000 0.000 0.000 1.563 0.095 0.000 0.000 0.142 0.095 0.047 0.047 0.047 0.047 0.095 0.047 0.095 0.095 0.095 0.047 0.047 1.042 0.237 0.237 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.095 0.000 0.047 0.047 0.758 0.284 0.142 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.237 0.521 0.474 1.753 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.095 0.000 0.142 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.711 0.379 0.095 0.142 0.095 0.142 0.474 0.616 0.189 0.189 0.189 0.142 0.237 0.379 0.758 0.568 5.306 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2111 112 112 2111 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2013/02/06 MEAN WIND SPEED =
6.23 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-76
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2012 -
DEC 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4
>=24.5 TOTAL 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.142 0.047 0.142 0.237 0.142 0.284 0.568 0.758 0.758 0.474 0.568 0.426 0.237 0.379 0.142 0.237 0.142 5.542 0.805 0.805 0.379 0.284 0.474 0.426 0.426 0.189 0.474 0.237 0.142 0.474 0.853 0.616 0.284 0.332 7.200 0.663 0.805 0.426 0.095 0.000 0.095 0.000 0.000 0.095 0.095 0.047 0.095 0.332 0.379 0.521 1.184 4.832 0.758 0.568 0.805 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.379 1.184 1.611 1.184 6.537 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.332 0.805 1.516 0.095 2.748 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.568 0.142 0.000 0.758 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.274 2.321 1.847 0.568 0.758 1.090 1.232 0.947 1.042 0.900 0.663 0.853 2.321 3.695 4.311 2.937 0.000 27.759 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2111 586 586 2111 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2013/02/06 MEAN WIND SPEED 7.06 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-77
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2012 -
DEC 31, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.047 0.142 0.095 0.142 0.000 0.047 0.095 0.047 0.047 0.000 0.047 0.000 0.047 0.474 0.474 0.474 0.663 1.090
- 0. 900 0.900 0.521 1.516 0.663 0.568 0.616 0.332 0.189 0.379 0.616 0.663 0.426 0.758 0.521 0.379 0.758 0.142 0.142 1.847 0.616 0.237 0.237 0.332 0.332 0.379 1.374 9.143 0.189 0.379 0.332 0.189 0.047 0.189 0.000 0.000 0.474 0.047 0.095 0.142 0.237 0.142 0.426 0.663 3.553 0.095 0.332 0.284 0.142 0.000 0.142 0.047 0.000 0.047 0.000 0.000 0.000 0.047 0.237 0.426 0.474 2.274 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.616 0.000 0.758 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.421 1.658 1.990 1.563 1.658 2.084 1.232 0.663 3.932 1.421 0.947 1.042 0.947 0.995 2.226 3.174 SUBTOTAL 0.853 10.374 0.000 26.954 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2111 569 569 2111 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL MEAN WIND SPEED =
4.49 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/02/06 E-78
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2012 -
DEC 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.189 0.095 0.047 0.095 0.142 0.142 0.284 0.142 0.095 0.000 0.047 0.000 0.047 0.000 0.000 0.047 1.184 0.853 1.042 1.279 0.995 1.042 0.853 0.521 0.568 0.095 0.142 0.095 0.142 0.095 0.284 0.900 1.326 1.090 0.900 0.521 0.189 0.189 0.000 0.189 0.474 0.095 0.000 0.000 0.047 0.047 0.095 0.711 5.874 0.142 0.332 0.711 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.237 1.516 0.000 0.047 0.189 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.047 0.000 0.332 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.842 2.416 2.890 1.895 1.326 1.374 1.137 0.853 1.137 0.189 0.237 0.095 0.237 0.189 0.474 1.895 1.374 10.090 0.000 19.185 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2111 405 405 2111 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2013/02/06 MEAN WIND SPEED =
3.33 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-79
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2012 -
DEC 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.013 0.007 0.007 0.004 0.002 0.002 0.001 0.000 0.001 0.000 0.000 0.000 0.000 0.000 0.001 0.009 0.047
>=24.5 TOTAL 0.758 0.284 0.379 0.237 0.047 0.095 0.095 0.000 0.142 0.047 0.000 0.095 0.047 0.000 0.189 0.426 2.842 2.037 1.279 1.090 0.521 0.332 0.237 0.095 0.047 0.000 0.047 0.000 0.000 0.000 0.000 0.095 1.421 7.200 0.521 0.711 0.758 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.379 2.558 0.000 0.142 0.284 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.095 0.568 0.000 0.000 0.189 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.189 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 3.329 2.423 2.707 0.856 0.381 0.333 0.190 0.048 0.143 0.095 0.047 0.095 0.048 0.000 0.380 2.330 0.000 13.406 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2111 283 283 2111 1
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND SPEED AND DIRECTION MEASURED AT 10.50 METER LEVEL DATE PRINTED: 2013/02/06 MEAN WIND SPEED 2.68 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-80
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT BROWNS FERRY NUCLEAR PLANT 2012 METEOROLOGICAL DATA TABLE 8A JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL RELEASE MODE AND ELEVATED RELEASE MODE)
FIRST QUARTER E-81
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2012 -
MAR 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.006 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.011 0.000 0.000 0.000 0.000 0.000 0.006 0.048 0.082 0.051 0.029 0.021 0.000 0.000 0.000 0.000 0.000 0.237 0.000 0.000 0.000 0.000 0.000 0.000 0.032 0.000 0.000 0.017 0.028 0.014 0.000 0.000 0.002 0.000 0.093 0.025 0.009 0.007 0.000 0.000 0.000 0.038 0.000 0.000 0.000 0.000 0.009 0.017 0.007 0.000 0.015 0.126 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.000 0.020 0.030 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.040 0.000 0.040
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.025 0.009 0.007 0.000 0.000 0.006 0.118 0.087 0.058 0.046 0.049 0.023 0.017 0.017 0.042 0.036 0.538 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2103.000 316.170 21.010 11.310 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-82 DATE PRINTED: 2012/05/15
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2012 -
MAR 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.000 0.000 0.000 0.000 0.000 0.014 0.046 0.009 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.078 0.000 0.006 0.000 0.000 0.000 0.000 0.015 0.000 0.000 0.000 0.000 0.006 0.004 0.000 0.004 0.000 0.035 0.000 0.000 0.007 0.000 0.000 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.021 0.007 0.000 0.008 0.052 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.032 0.041 0.112 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.042 0.000 0.042
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.001 0.006 0.007 0.000 0.000 0.010 0.029 0.046 0.009 0.000 0.000 0.015 0.025 0.045 0.078 0.049 0.320 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS GROUND LEVEL RELEASE STABILITY CLASS B GROUND LEVEL STABILITY CLASS B 2103.000 316.170 19.790 6.730 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/05/15 E-83
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2012 -
MAR 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.000 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.011 0.000 0.000 0.000 0.000 0.000 0.001 0.014 0.006 0.025 0.000 0.000 0.005 0.000 0.000 0.000 0.000 0.053 0.008 0.012 0.000 0.000 0.000 0.000 0.018 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.005 0.000 0.051 0.032 0.029 0.014 0.000 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.018 0.023 0.042 0.037 0.028 0.229 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.106 0.010 0.074 0.189 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.036 0.082 0.000 0.118
>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.040 0.041 0.014 0.000 0.005 0.001 0.032 0.010 0.025 0.007 0.000 0.023 0.032 0.183 0.134 0.102 0.651 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 2103.000 316.170 56.880 13.700 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/05/15 E-84
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2012 -
MAR 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.016 0.033 0.024 0.016 0.003 0.000 0.002 0.000 0.000 0.000 0.103 0.031 0.015 0.008 0.008 0.016 0.039 0.120 0.025 0.035 0.030 0.009 0.027 0.010 0.000 0.001 0.004 0.379 0.039 0.038 0.025 0.022 0.000 0.059 0.086 0.032 0.024 0.010 0.000 0.075 0.031 0.052 0.027 0.045 0.566 0.065 0.096 0.017 0.019 0.000 0.000 0.000 0.010 0.000 0.044 0.012 0.056 0.188 0.141 0.221 0.204 1.071 0.083 0.035 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.056 0.350 0.251 0.155 0.929 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.128 0.094 0.080 0.301
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.219 0.183 0.050 0.049 0.016 0.107 0.223 0.100 0.083 0.099 0.025 0.158 0.287 0.670 0.594 0.487 3.349 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 2103.000 316.170 654.990 70.430 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/05/15 E-85
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2012 -
MAR 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.003 0.000 0.008 0.000 0.000 0.000 0.000 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.019 0.012 0.019 0.013 0.001 0.017 0.055 0.147 0.297 0.083 0.033 0.022 0.016 0.005 0.003 0.005 0.005 0.733 0.043 0.072 0.036 0.069 0.032 0.375 0.281 0.147 0.297 0.088 0.010 0.028 0.063 0.014 0.057 0.037 1.648 0.065 0.069 0.050 0.015 0.000 0.130 0.094 0.000 0.256 0.134 0.009 0.034 0.026 0.009 0.078 0.074 1.041 0.047 0.023 0.015 0.000 0.000 0.036 0.107 0.045 0.492 0.437 0.010 0.019 0.052 0.036 0.264 0.130 1.713 0.020 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.013 0.047 0.194 0.107 0.381 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.186 0.186 0.114 0.093 0.049 0.596 0.629 0.488 1.135 0.692 0.050 0.097 0.158 0.109 0.597 0.353 5.535 HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 2103.000 316.170 924.810 116.400 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/05/15 E-86
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2012 -
MAR 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.001 0.014 0.008 0.019 0.011 0.013 0.011 0.003 0.003 0.001 0.000 0.000 0.000 0.000 0.084 0.059 0.026 0.015 0.014 0.030 0.037 0.179 0.485 0.221 0.036 0.014 0.010 0.010 0.000 0.001 0.031 1.166 0.078 0.080 0.016 0.015 0.111 0.070 0.079 0.178 0.223 0.058 0.009 0.004 0.000 0.000 0.010 0.064 0.997 0.000 0.055 0.007 0.000 0.000 0.000 0.055 0.000 0.394 0.069 0.000 0.000 0.000 0.000 0.000 0.022 0.602 0.009 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.220 0.117 0.000 0.000 0.009 0.000 0.000 0.000 0.364 0.000 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.146 0.180 0.039 0.043 0.149 0.125 0.324 0.676 1.069 0.283 0.026 0.015 0.019 0.000 0.011 0.117 3.223 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 2103.000 316.170 368.900 67.770 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/05/15 E-87
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JAN 1, 2012 -
MAR 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.001 0.001 0.002 0.000 0.029 0.046 0.059 0.092 0.033 0.000 0.000 0.007 0.000 0.000 0.000 0.000 0.272 0.027 0.004 0.000 0.011 0.003 0.045 0.070 0.536 0.159 0.002 0.002 0.000 0.000 0.000 0.000 0.002 0.863 0.056 0.006 0.010 0.000 0.000 0.000 0.000 0.115 0.018 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.211 0.000 0.000 0.012 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.012 0.000 0.042 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.050 0.000 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.084 0.063 0.032 0.011 0.031 0.091 0.130 0.744 0.210 0.002 0.002 0.007 0.000 0.000 0.000 0.010 1.418 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 2103.000 316.170 56.620 29.830 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/05/15 E-88
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2012 -
MAR 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.090 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.136 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.123 0.000 0.000 0.000 0.000 0.000 0.123 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.077 0.078 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.155 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.166 0.172 0.000 0.123 0.000 0.000 0.000 0.000 0.000 0.461 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 2103.000 1786.830 21.010 9.700 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/05/15 E-89
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2012 -
MAR 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.127 0.081 0.042 0.000 0.040 0.042 0.040 0.000 0.000 0.000 0.373 0.000 0.039 0.000 0.000 0.000 0.000 0.000 0.039 0.039 0.000 0.039 0.000 0.000 0.000 0.000 0.000 0.156 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.039 0.000 0.000 0.000 0.000 0.218 0.120 0.082 0.000 0.079 0.042 0.040 0.000 0.000 0.000 0.621 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 2103.000 1786.830 19.790 13.060 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/05/15 E-90
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2012 -
MAR 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.143 0.048 0.095 0.000 0.190 0.000 0.000 0.000 0.000 0.000 0.476 0.000 0.000 0.000 0.000 0.000 0.000 0.140 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.140 0.080 0.000 0.000 0.000 0.000 0.000 0.204 0.043 0.000 0.082 0.000 0.000 0.204 0.000 0.040 0.040 0.693 0.038 0.078 0.000 0.000 0.000 0.000 0.077 0.000 0.000 0.000 0.077 0.039 0.000 0.190 0.038 0.000 0.536 0.000 0.000 0.000 0.000 0.000 0.000 0.057 0.000 0.000 0.000 0.000 0.000 0.000 0.022 0.000 0.116 0.195
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.013 0.000 0.013 TOTAL 0.118 0.078 0.000 0.000 0.000 0.000 0.621 0.091 0.095 0.082 0.267 0.039 0.204 0.212 0.091 0.156 2.053 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 2103.000 1786.830 56.880 43.180 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/05/15 E-91
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2012 -
MAR 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.048 0.143 0.095 0.000 0.048 0.000 0.048 0.048 0.238 0.000 0.476 0.190 0.095 0.190 0.095 0.000 0.048 1.712 0.190 0.143 0.285 0.238 0.190 0.095 0.856 0.666 0.143 0.285 0.238 0.333 0.285 0.238 0.285 0.190 4.660 0.367 0.454 0.364 0.229 0.090 0.092 0.505 0.092 0.136 0.088 0.228 0.271 0.414 0.410 0.318 0.227 4.284 0.786 0.880
- 0. 675 0.214 0.126 0.295 0.374 0.208 0.702 0.168 0.336 0.750 0.702 1.332 1.034
- 0. 908 9.490 0.308 0.463 0.000 0.000 0.000 0.000 0.386 0.190 0.039 0.233 0.078 0.422 0.696 0.690 0.773 0.999 5.274 0.198 0.126 0.000 0.000 0.000 0.000 0.291 0.208 0.048 0.055 0.050 0.000 0.096 0.402 0.446 0.358 2.278
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.000 0.000 0.000 0.015 0.014 0.015 TOTAL 1.992 2.160 1.324 0.728 0.407 0.529 2.459 1.602 1.067 1.311 1.120 1.870 2.431 3.183 2.869 2.745 0.051 27.796 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2103.000 1786.830 654.990 584.560 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/05/15 E-92
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2012 -
MAR 31, 2012 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 N
NNE NE ENE E
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.048 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.190 0.095 0.238 0.095 0.000 0.143 0.048 0.238 0.143 0.143 0.095 0.285 0.333 0.048 0.048 0.143 0.095 2.187 0.238 0.143 0.333 0.190 0.285 0.380 0.428 0.713 0.333 0.523 0.713 0.333 0.238 0.285 0.143 0.190 5.468 0.276 0.231 0.318 0.232 0.232 0.369 0.593 0.590 0.648 0.462 0.637 0.409 0.318 0.364 0.273 0.320 0.592 0.750 1.166 0.292 0.466 1.065 0.990 0.873 1.125 0.621 0.791 0.337 0.424 0.253 0.503 1.507 0.274 0.426 0.197 0.000 0.000 0.118 2.242 1.342 1.162 1.116 0.692 0.308 0.038 0.232 0.501 0.659 9.307 0.000 0.036 0.000 0.000 0.000 0.000 0.559 0.770 0.710 0.700 0.142 0.000 0.035 0.038 0.071 0.056 3.117 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 0.009 0.000 0.000 0.000 0.000 0.000 0.010 0.044 0.037 0.044 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.485 1.824 2.109 0.714 1.126 2.076 5.108 4.476 4.157 3.562 3.261
- 1. 767 1.100 1.220
- 1. 632 2.827 SUBTOTAL 0.000 6.272 11.754 0.145 38.441 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 2103.000 1786.830 924.810 808.410 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/05/15 E-93
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2012 -
MAR 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.143 0.048 0.000 0.000 0.095 0.048 0.048 0.000 0.048 0.048 0.095 0.143 0.000 0.000 0.713 0.048 0.095 0.095 0.095 0.095 0.095 0.143 0.190 0.143 0.143 0.000 0.048 0.048 0.333 0.190 0.048 1.807 0.090 0.137 0.000 0.138 0.137 0.046 0.360 0.364 0.507 0.554 0.411 0.046 0.139 0.047 0.138 0.090 3.205 0.414 0.499 0.369 0.289 0.210 0.409 0.325 0.872 0.749 0.380 0.594 0.000 0.043 0.000 0.000 0.296 5.450 0.000 0.195 0.079 0.000 0.000 0.000 0.193 0.887 1.048 0.117 0.000 0.000 0.000 0.000 0.000 0.000 2.519 0.000 0.036 0.000 0.000 0.000 0.000 0.055 0.374 0.083 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.548
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.029 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.552 0.963 0.686 0.570 0.442 0.551 1.171 2.764 2.625 1.194 1.053 0.141 0.325 0.522 0.329 0.433 0.029 14.319 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 2103.000 1786.830 368.900 301.130 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/05/15 E-94
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JAN 1, 2012 -
MAR 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.048 0.000 0.000 0.000 0.000 0.143 0.000 0.000 0.000 0.048 0.000 0.048 0.000 0.000 0.000 0.000 0.000 0.048 0.000 0.000 0.048 0.000 0.190 0.044 0.000 0.044 0.091 0.000 0.046 0.000 0.000 0.089 0.000 0.045 0.045 0.000 0.000 0.000 0.000 0.406 0.000 0.127 0.043 0.000 0.000 0.000 0.000 0.000 0.248 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.418 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.078 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.117 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.044 0.127 0.135 0.139 0.000 0.094 0.000 0.039 0.464 0.000 0.045 0.140 0.000 0.000 0.048 0.000 1.274 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 2103.000 1786.830 56.620 26.790 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY
= 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/05/15 E-95
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT BROWNS FERRY NUCLEAR PLANT 2012 METEOROLOGICAL DATA TABLE 8B JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL RELEASE MODE AND ELEVATED RELEASE MODE)
SECOND QUARTER E-96
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2012 -
JUN 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.022 0.033 0.058 0.138 0.056 0.009 0.000 0.000 0.000 0.000 0.000 0.316 0.000 0.000 0.000 0.000 0.000 0.041 0.085 0.046 0.051 0.042 0.010 0.027 0.007 0.001 0.000 0.000 0.310 0.027 0.029 0.004 0.000 0.000 0.035 0.000 0.000 0.000 0.000 0.000 0.012 0.004 0.013 0.009 0.022 0.155 0.091 0.097 0.033 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.012 0.011 0.061 0.118 0.423 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.102 0.125 0.236 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.118 0.126 0.037 0.000 0.000 0.098 0.118 0.104 0.189 0.097 0.019 0.039 0.023 0.034 0.172 0.264 1.440 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2180.000 179.140 97.030 31.400 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/08/20 E-97
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2012 -
JUN 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.006 0.004 0.004 0.000 0.000 0.000 0.000 0.000 0.000 0.022 0.000 0.000 0.000 0.000 0.000 0.058 0.004 0.000 0.000 0.006 0.001 0.011 0.005 0.001 0.000 0.000 0.086 0.020 0.013 0.013 0.006 0.000 0.008 0.000 0.000 0.000 0.000 0.000 0.012 0.005 0.011 0.012 0.000 0.100 0.045 0.020 0.021 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.015 0.039 0.029 0.170 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.016 0.055 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.065 0.033 0.034 0.006 0.000 0.066 0.011 0.006 0.004 0.010 0.001 0.023 0.009 0.028 0.090 0.045 0.432 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 2180.000 179.140
- 95. 630 9.420 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/08/20 E-98
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2012 -
JUN 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.000 0.008 0.016 0.000 0.000 0.006 0.004 0.000 0.000 0.000 0.000 0.000 0.043 0.004 0.000 0.000 0.000 0.000 0.024 0.000 0.000 0.000 0.011 0.004 0.011 0.003 0.000 0.000 0.002 0.058 0.011 0.015 0.000 0.002 0.003 0.014 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.007 0.007 0.005 0.071 0.012 0.013 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.036 0.021 0.033 0.117 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.035 0.000 0.035 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.027 0.028 0.009 0.002 0.003 0.046 0.016 0.000 0.000 0.017 0.008 0.011 0.010 0.044 0.063 0.040 0.324 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 2180.000 179.140 157.400 7.060 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/08/20 E-99
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-D.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2012 -
JUN 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.000 0.000 0.000 0.000 0.032 0.067 0.074 0.036 0.049 0.088 0.002 0.011 0.003 0.000 0.000 0.000 0.361 0.031 0.012 0.001 0.000 0.056 0.190 0.000 0.000 0.009 0.032 0.011 0.028 0.061 0.029 0.027 0.042 0.530 0.081 0.043 0.035 0.009 0.015 0.018 0.000 0.000 0.000 0.000 0.000 0.034 0.060 0.064 0.059 0.077 0.495 0.085 0.048 0.006 0.000 0.000 0.017 0.000 0.000 0.000 0.000 0.000 0.008 0.035 0.156 0.160 0.139 0.653 0.028 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.018 0.016 0.062 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.225 0.102 0.042 0.009 0.108 0.292 0.074 0.036 0.058 0.119 0.013 0.081 0.159 0.249 0.264 0.274 2.106 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 2180.000 179.140 772.060 45.920 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/08/20 E-100
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2012 -
JUN 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.001 0.001 0.006 0.007 0.004 0.000 0.005 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.031 0.072 0.010 0.006 0.044 0.135 0.099 0.024 0.091 0.118 0.168 0.022 0.025 0.047 0.013 0.001 0.038 0.912 0.058 0.090 0.029 0.014 0.112 0.177 0.000 0.000 0.007 0.117 0.006 0.005 0.083 0.011 0.022 0.095 0.825 0.065 0.094 0.041 0.000 0.015 0.055 0.000 0.000 0.000 0.000 0.000 0.008 0.037 0.011 0.020 0.029 0.374 0.017 0.066 0.032 0.000 0.000 0.021 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.006 0.033 0.068 0.250 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.212 0.261 0.109 0.063 0.268 0.355 0.024 0.096 0.133 0.285 0.029 0.037 0.174 0.041 0.075 0.230 2.392 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 2180.000 179.140 630.820 52.150 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/08/20 E-101
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2012 -
JUN 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.019 0.019 0.002 0.008 0.012 0.000 0.006 0.000 0.008 0.000 0.000 0.001 0.000 0.084
- 0. 126 0.063 0.048 0.046 0.080 0.040 0.007 0.006 0.001 0.021 0.009 0.052 0.002 0.001 0.000 0.028 0.530 0.083 0.146 0.030 0.015 0.056 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.022 0.000 0.000 0.016 0.373 0.006 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.023 0.038 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.215 0.217 0.087 0.079 0.155 0.050 0.015 0.018 0.001 0.027 0.009 0.060 0.024 0.001 0.002 0.067 1.025 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 2180.000 179.140 311.890 22.350 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/08/20 E-102
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE APR 1, 2012 -
JUN 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.002 0.001 0.001 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 7.5-12.4 12.5-18.4 18.5-24.4 0.011 0.002 0.004 0.006 0.019 0.005 0.000 0.000 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.059 0.110 0.060 0.041 0.037 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.005 0.261 0.111 0.043 0.006 0.003 0.011 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.173 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>-24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.233 0.105 0.051 0.047 0.038 0.005 0.000 0.000 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.497 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 2180.000 179.140 115.170 10.840 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/08/20 E-103
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2012 -
JUN 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.138 0.138 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.367 0.000 0.000 0.000 0.000 0.000 0.000 0.090 0.439 0.134 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.710 0.000 0.039 0.000 0.000 0.000 0.000 0.161 0.369 0.531 0.164 0.000 0.000 0.000 0.000 0.000 0.000 1.264 0.000 0.225 0.000 0.000 0.000 0.000 0.036 0.076 0.150 0.000 0.000 0.000 0.000 0.000 0.111 0.000 0.599 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.025 0.025
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.264 0.000 0.000 0.000 0.000 0.471 1.022 0.862 0.164 0.092 0.000 0.000 0.000 0.111 0.025 3.011 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS ELEVATED RELEASES STABILITY CLASS A ELEVATED STABILITY CLASS A 2180.000 2000.860 97.030 65.630 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/08/20 E-104
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2012 -
JUN 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.046 0.000 0.000 0.229 0.183 0.138 0.138 0.092 0.000 0.138 0.000 0.046 0.000 1.009 0.000 0.000 0.000 0.000 0.000 0.000 0.487 0.128 0.092 0.045 0.000 0.000 0.000 0.043 0.000 0.000 0.794 0.161 0.160 0.121 0.000 0.000 0.000 0.250 0.000 0.408 0.122 0.080 0.000 0.000 0.040 0.080 0.080 1.502 0.038 0.111 0.000 0.000 0.000 0.000 0.075 0.038 0.076 0.037 0.000 0.000 0.000 0.000 0.111 0.074 0.561 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.043 0.043
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.199 0.271 0.121 0.046 0.000 0.000 1.041 0.396 0.714 0.341 0.172 0.000 0.138 0.083 0.237 0.197 3.955 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 2180.000 2000.860 95.630 86.210 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/08/20 E-105
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2012 -
JUN 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.138 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.229 0.000 0.000 0.000 0.000 0.000 0.000 0.505 0.138 0.183 0.229 0.183 0.321 0.413 0.092 0.000 0.046 2.110 0.043 0.000 0.000 0.000 0.000 0.090 0.347 0.092 0.000 0.089 0.130 0.089 0.089 0.089 0.043 0.000 1.100 0.641 0.444 0.078 0.000 0.000 0.000 0.116 0.042 0.122 0.202 0.121 0.122 0.084 0.202 0.081 0.122 2.378 0.036 0.037 0.038 0.000 0.000 0.000 0.038 0.038 0.075 0.000 0.000 0.000 0.000 0.075 0.112 0.411 0.859 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.036 0.000 0.000 0.000 0.000 0.000 0.000 0.154 0.030 0.220
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.720 0.481 0.117 0.000 0.000 0.090 1.051 0.483 0.380 0.567 0.434 0.532 0.586 0.457 0.389 0.609 6.896 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 2180.000 2000.860 157.400 150.340 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/08/20 E-106
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2012 -
JUN 30, 2012 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 0.138 0.000 0.046 0.000 0.092 0.000 0.138 0.550 0.734 0.505 0.413 0.550 0.275 0.092 0.046 0.092 0.138 3.670 0.183 0.229 0.183 0.000 0.092 0.229 0.275 0.734 0.688 0.596 0.780 0.826 0.734 0.367 0.183 0.229 6.330 0.613 0.489 0.180 0.173 0.133 0.222 0.443 0.176 0.304 0.400 0.395 0.402 0.528 0.750 0.745 0.440 1.132 0.843 0.249 0.084 0.083 0.612 1.075 0.555 0.599 0.400 0.571 0.933 0.528 1.777 1.130 1.047 0.784 0.227 0.000 0.000 0.000 0.038 0.563 1.123 0.522 0.262 0.076 0.038 0.076 0.227 0.522 0.338 4.796 0.077 0.000 0.000 0.000 0.000 0.000 0.125 0.034 0.000 0.000 0.000 0.000 0.000 0.036 0.063 0.030 0.365
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 2.789 1.834 0.612 0.350 0.307 1.239 3.078 3.356 2.618 2.072 2.372 2.474 2.004 3.203 2.735 2.268 SUBTOTAL 6.393 11.617 0.000 33.309 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 2180.000 2000.860 772.060 726.140 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/08/20 E-107
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2012 -
JUN 30, 2012 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 N
NNE NE ENE E
WNW NW NNW 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.046 0.138 0.046 0.046 0.138 0.046 0.138 0.367 0.138
- 0. 138 0.367 0.229 0.138 0.092 0.092 0.229 2.385 0.413 0.183 0.000 0.092 0.138 0.046 0.183 0.550 0.917 0.826 0.550 0.321 0.275 0.046 0.092 0.229 4.862 0.355 0.043 0.263 0.045 0.351 0.399 0.705 0.487 0.393 0.219 0.622 0.179 0.579 0.222 0.220 0.358 1.207 1.329 0.445 0.250 0.165 0.412 0.849 1.244 0.726 0.810 0.322 0.082 0.448 0.528 0.243 1.057 0.150 0.715 0.152 0.000 0.000 0.038 0.262 0.824 0.633 0.075 0.038 0.000 0.000 0.038 0.262 0.300 3.487 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.061 0.100 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.161
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 2.171 2.408 0.906 0.433 0.791 0.941 2.137 3.580 2.953 2.067 1.899 0.811 1.440 0.926 0.908 2.174 SUBTOTAL 5.439 10.117 0.000 26.544 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 2180.000 2000.860 630.820 578.670 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/08/20 E-108
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2012 -
JUN 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.138 0.046 0.046 0.046 0.092 0.092 0.138 0.092 0.092 0.046 0.229 0.183 0.138 0.138 0.000 0.046 0.046 1.468 0.138 0.183 0.092 0.092 0.092 0.138 0.183 0.046 0.505 0.229 0.229 0.229 0.367 0.183 0.138 0.275 3.119 0.132 0.175 0.350 0.220 0.267 0.397 0.136 0.176 0.533 0.222 0.044 0.000 0.180 0.091 0.135 0.224 3.282 0.692 0.837 0.649 0.162 0.165 0.289
- 0. 659 0.081 0.245 0.328 0.000 0.000 0.082 0.122 0.042 0.282 4.635 0.113 0.341 0.038 0.000 0.000 0.000 0.000 0.074 0.038 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.604 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.036 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.036
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.121 1.582 1.221 0.566 0.615 0.961 1.070 0.550 1.367 1.055 0.457 0.367 0.767 0.396 0.361 0.827 0.000 13.282 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 2180.000 2000.860 311.890 289.540 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/08/20 E-109
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE APR 1, 2012 -
JUN 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.138 0.092 0.046 0.046 0.046 0.092 0.046 0.138 0.092 0.046 0.000 0.138 0.000 0.046 0.000 0.046 0.092 0.963 0.092 0.000 0.046 0.092 0.229 0.046 0.046 0.046 0.000 0.046 0.046 0.000 0.046 0.092 0.138 0.046 1.009 0.000 0.045 0.306 0.130 0.044 0.000 0.089 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.089 0.794 0.399 0.274 0.367 0.285 0.123 0.000 0.000 0.042 0.082 0.000 0.000 0.000 0.000 0.000 0.042 0.039 1.654 0.038 0.152 0.038 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.228 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.621 0.517 0.802 0.553 0.534 0.138 0.272 0.180 0.173 0.046 0.183 0.000 0.092 0.092 0.317 0.266 4.786 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 2180.000 2000.860 115.170 104.330 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/08/20 E-110
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT BROWNS FERRY NUCLEAR PLANT 2012 METEOROLOGICAL DATA TABLE 8C JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL RELEASE MODE AND ELEVATED RELEASE MODE)
THIRD QUARTER E-111
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2012 -
SEP 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.013 0.071 0.057 0.071 0.155 0.019 0.000 0.000 0.000 0.000 0.000 0.390 0.000 0.000 0.000 0.000 0.000 0.103 0.077 0.036 0.018 0.084 0.025 0.009 0.007 0.001 0.000 0.000 0.362 0.011 0.000 0.004 0.000 0.000 0.008 0.000 0.000 0.000 0.000 0.000 0.001 0.070 0.009 0.005 0.003 0.110 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.033 0.083 0.026 0.014 0.164 0.000 0.000 0.011 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.021 0.031 0.011 0.073 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.018 0.000 0.015 0.000 0.004 0.124 0.148 0.093 0.089 0.239 0.045 0.010 0.110 0.114 0.062 0.028 1.098 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 1899.000 114.410 67.530 20.860 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/11/19 E-112
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2012 -
SEP 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.009 0.011 0.009 0.060 0.011 0.000 0.000 0.000 0.000 0.000 0.109 0.000 0.000 0.000 0.000 0.000 0.032 0.005 0.000 0.000 0.011 0.000 0.003 0.004 0.000 0.000 0.002 0.055 0.016 0.014 0.003 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.025 0.018 0.010 0.005 0.091 0.014 0.013 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.004 0.007 0.056 0.023 0.116 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.011 0.000 0.011 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.029 0.027 0.003 0.000 0.000 0.041 0.014 0.011 0.009 0.070 0.011 0.003 0.033 0.026 0.076 0.029 0.382 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 1899.000 114.410 62.370 7.260 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/11/19 E-113
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2012 -
SEP 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.017 0.005 0.014 0.015 0.000 0.002 0.000 0.000 0.000 0.052 0.004 0.000 0.000 0.000 0.008 0.010 0.007 0.000 0.000 0.011 0.000 0.019 0.015 0.001 0.001 0.000 0.076 0.014 0.004 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.015 0.026 0.008 0.005 0.072 0.000 0.000 0.005 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.007 0.032 0.010 0.060 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.018 0.004 0.005 0.000 0.008 0.010 0.007 0.017 0.005 0.024 0.015 0.019 0.038 0.033 0.040 0.015 0.259 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS C OF GROUND LEVEL STABILITY CLASS C 1899.000 114.410 121.750 4.910 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/11/19 E-114
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2012 -
SEP 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.004 0.002 0.000 0.000 0.008 0.138 0.098 0.085 0.128 0.165 0.052 0.014 0.004 0.000 0.003 0.000 0.702 0.012 0.015 0.017 0.014 0.053 0.245 0.031 0.000 0.000 0.015 0.000 0.046 0.060 0.008 0.000 0.004 0.519 0.014 0.028 0.006 0.000 0.038 0.146 0.000 0.000 0.000 0.000 0.011 0.000 0.057 0.026 0.004 0.029 0.361 0.000 0.008 0.007 0.018 0.010 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.033 0.044 0.035 0.204 0.000 0.011 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.011 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.029 0.065 0.030 0.033 0.110 0.569 0.129 0.085 0.130 0.180 0.062 0.060 0.130 0.067 0.051 0.068 1.799 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 1899.000 114.410 793.600 34.160 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/11/19 E-115
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2012 -
SEP 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.011 0.001 0.000 0.006 0.003 0.032 0.008 0.004 0.004 0.000 0.007 0.000 0.000 0.075 0.008 0.006 0.011 0.028 0.091 0.080 0.043 0.046 0.108 0.097 0.023 0.055 0.033 0.007 0.000 0.000 0.636 0.049 0.049 0.036 0.057 0.186 0.078 0.000 0.000 0.000 0.000 0.000 0.027 0.056 0.014 0.017 0.039 0.607 0.000 0.042 0.013 0.006 0.008 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.012 0.015 0.105 0.000 0.025 0.026 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.016 0.009 0.091 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.057 0.123 0.085 0.103 0.295 0.167 0.049 0.049 0.140 0.105 0.027 0.085 0.089 0.034 0.045 0.063 1.514 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 1899.000 114.410 537.700 28.750 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/11/19 E-116
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2012 -
SEP 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL TOTAL TOTAL TOTAL TOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.012 0.009 0.005 0.003 0.004 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.003 0.000 0.037 0.040 0.031 0.015 0.073 0.066 0.027 0.000 0.000 0.012 0.000 0.010 0.000 0.000 0.000 0.000 0.021 0.295 0.033 0.042 0.012 0.033 0.075 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.000 0.000 0.043 0.239 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.085 0.082 0.041 0.108 0.146 0.029 0.000 0.000 0.012 0.000 0.010 0.000 0.002 0.000 0.003 0.064 0.581 HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 1899.000 114.410 215.770 11.030 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/11/19 E-117
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE JUL 1, 2012 -
SEP 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.003 0.006 0.000 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.013 0.059 0.011 0.017 0.023 0.023 0.000 0.004 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.021 0.159 0.141 0.017 0.007 0.027 0.004 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.014 0.211 0.000 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.203 0.034 0.025 0.062 0.027 0.000 0.004 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.037 0.392 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 1899.000 114.410 100.280 7.440 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/11/19 E-118
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2012 -
SEP 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.053 0.000 0.000 0.000 0.105 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.300 0.253 0.100 0.253 0.153 0.000 0.000 0.000 0.000 1.058 0.000 0.000 0.000 0.000 0.000 0.000 0.508 0.184 0.145 0.327 0.000 0.000 0.045 0.000 0.000 0.000 1.209 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.042 0.043 0.000 0.000 0.000 0.000 0.000 0.000 0.085 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.508 0.483 0.440 0.470 0.253 0.205 0.098 0.000 0.000 0.000 2.458 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 1899.000 1784.590 67.530 46.670 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/11/19 E-119
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2012 -
SEP 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.000 0.000 0.000 0.000 0.000 0.000 0.105 0.000 0.000 0.158 0.158 0.105 0.053 0.000 0.000 0.000 0.579 0.000 0.000 0.000 0.000 0.000 0.000 0.100 0.049 0.150 0.154 0.049 0.052 0.251 0.000 0.000 0.000 0.805 0.000 0.000 0.000 0.000 0.000 0.000 0.096 0.137 0.234 0.186 0.045 0.000 0.239 0.091 0.048 0.000 1.076 0.000 0.000 0.000 0.000 0.000 0.000 0.085 0.000 0.130 0.043 0.000 0.000 0.000 0.087 0.044 0.000 0.389 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.387 0.240 0.513 0.541 0.252 0.157 0.542 0.178 0.092 0.000 2.902 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 1899.000 1784.590 62.370 55.110 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY
= 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/11/19 E-120
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2012 -
SEP 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.105 0.105 0.000 0.000 0.053 0.000 0.000 0.000 0.000 0.316 0.000 0.000 0.000 0.000 0.053 0.000 0.105 0.263 0.211 0.263 0.211 0.316 0.316 0.000 0.000 0.000 1.738 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.103 0.049 0.152 0.205 0.000 0.515 0.150 0.053 0.000 1.226 0.182 0.143 0.000 0.000 0.000 0.000 0.411 0.095 0.462 0.142 0.187 0.047 0.143 0.369 0.044 0.000 2.226 0.000 0.000 0.000 0.000 0.000 0.000 0.044 0.128 0.131 0.087 0.000 0.000 0.000 0.042 0.171 0.042 0.646 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.182 0.143 0.000 0.000 0.053 0.000 0.613
- 0. 695 0.958 0.645
- 0. 603 0.416 0.974 0.560 0.268 0.042 6.153 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 1899.000 1784.590 121.750 116.840 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/11/19 E-121
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2012 -
SEP 30, 2012 WIND DIRECTION WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 N
NNE NE ENE E
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.053 0.105 0.105 0.000 0.000 0.000 0.000 0.000 0.316 0.158 0.105 0.158 0.158 0.158 0.105 0.316 0.685 0.685
- 0. 632 0.579 0.474 0.263 0.000 0.053 0.158 0.316 0.369 0.316 0.211 0.105 0.211 0.579 0.790 1.474 1.843 1.001 1.106 1.053 0.421 0.316 0.316 0.657 0.203 0.302 0.306 0.155 0.249 0.302 0.508 0.966 1.130 0.823 0.817 1.621 0.360 0.255 0.357 9.011 0.427 0.425 0.186 0.048 0.048 0.463 1.150 1.889 2.788 1.534 0.138 0.234 0.938 1.078
- 0. 693 0.279 12.321 0.000 0.042 0.044 0.000 0.000 0.129 0.509 0.988 0.558 0.302 0.086 0.000 0.043 0.085 0.087 0.172 3.044 0.000 0.000 0.042 0.000 0.000 0.000 0.145 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.187
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.558 1.144 1.048 0.723 0.467 1.156 3.002 4.913 6.524 5.547 2.732 2.631 3.919 1.944 1.403 1.281 SUBTOTAL 4.687 10.427 0.000 39.992 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS D OF ELEVATED STABILITY CLASS D 1899.000 1784.590 793.600 759.440 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/11/19 E-122
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2012 -
SEP 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.053 0.000 0.000 0.000 0.000 0.053 0.053 0.053 0.053 0.000 0.000 0.000 0.000 0.000 0.053 0.316 0.263 0.053 0.105 0.421 0.158 0.053 0.105 0.369 0.316 0.316 0.263 0.316 0.211 0.211 0.000 0.211 3.370 0.527 0.579 0.211 0.158 0.105 0.421 0.737 0.474 0.527 0.632 0.948 0.632 0.632 0.158 0.158 0.053 6.951 0.103 0.559 0.457 0.357 0.349 0.451 0.456 0.806 0.561 0.759 0.153 0.308 1.371 0.309 0.051 0.355 7.404 0.514 0.553 0.412 0.242 0.711 1.120 1.080 0.466 1.109 0.230 0.090 0.094 0.573 0.470 0.000 0.188 7.852 0.087 0.000 0.043 0.086 0.044 0.131 0.000 0.128 0.130 0.000 0.000 0.000 0.000 0.000 0.128 0.131 0.908 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.494 1.797 1.229 1.264 1.367 2.176 2.431 2.295 2.695 1.989 1.454 1.350 2.786 1.148 0.336 0.989 0.000 26.801 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 1899.000 1784.590 537.700 508.950 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/11/19 E-123
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2012 -
SEP 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.053 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.053 0.000 0.000 0.053 0.105 0.000 0.158 0.105 0.105 0.211 0.263 0.053 0.000 0.053 0.105 0.000 0.105 1.316 0.000 0.105 0.211 0.263 0.263 0.158 0.263 0.211 0.105 0.105 0.158 0.053 0.053 0.053 0.000 0.105 2.106 0.101 0.504 0.202 0.151 0.305 0.450 0.356 0.201 0.151 0.154 0.000 0.104 0.000 0.051 0.000 0.206 2.935
- 0. 645 0.553 0.504 0.185 0.235 1.041 0.519 0.192 0.143 0.048 0.000 0.000 0.000 0.000 0.000 0.045 4.111 0.044 0.087 0.044 0.086 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.261 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.789 1.249 1.013 0.791 0.804 1.859 1.244 0.709 0.610 0.571 0.211 0.156 0.105 0.209 0.000 0.461 0.000 10.781 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 1899.000 1784.590 215.770 204.740 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/11/19 E-124
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE JUL 1, 2012 -
SEP 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.004 0.006 0.001 0.006 0.001 0.003 0.007 0.006 0.007 0.000 0.006 0.000 0.001 0.000 0.003 0.053 0.000 0.105 0.000 0.000 0.053 0.000 0.000 0.053 0.053 0.053 0.000 0.053 0.000 0.000 0.000 0.000 0.369 0.000 0.053 0.211 0.053 0.158 0.053 0.105 0.211 0.158 0.211 0.000 0.158 0.000 0.053 0.000 0.105 1.527 0.000 0.053 0.316 0.158 0.105 0.000 0.105 0.000 0.211 0.053 0.105 0.000 0.053 0.000 0.000 0.000 1.159 0.051 0.155 0.150 0.052 0.050 0.053 0.053 0.051 0.053 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.718 0.000 0.411 0.368 0.096 0.145 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.021 0.000 0.044 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.044 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.051 0.825 1.050 0.360 0.517 0.107 0.266 0.322 0.480 0.374 0.105 0.216 0.053 0.054 0.000 0.108 4.889 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 1899.000 1784.590 100.280 92.840 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY
= 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/11/19 E-125
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT BROWNS FERRY NUCLEAR PLANT 2012 METEOROLOGICAL DATA TABLE 8D JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR SPLIT LEVEL RELEASES (GROUND LEVEL RELEASE MODE AND ELEVATED RELEASE MODE)
FOURTH QUARTER E-126
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2012 -
DEC 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.014 0.041 0.026 0.000 0.000 0.000 0.000 0.000 0.000 0.082 0.000 0.000 0.000 0.000 0.006 0.029 0.011 0.003 0.029 0.035 0.000 0.000 0.000 0.000 0.000 0.000 0.112 0.010 0.000 0.000 0.010 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.020 0.024 0.031 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.017 0.000 0.008 0.006 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.024 0.000 0.000 0.024 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.052 0.000 0.052
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.034 0.031 0.000 0.010 0.006 0.029 0.013 0.017 0.070 0.060 0.000 0.008 0.017 0.024 0.060 0.006 0.384 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS A OF GROUND LEVEL STABILITY CLASS A 2111.000 233.630 10.630 8.100 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY
= 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/02/06 E-127
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2012 -
DEC 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.008 0.004 0.000 0.004 0.003 0.000 0.000 0.000 0.000 0.000 0.000 0.019 0.000 0.000 0.000 0.005 0.002 0.001 0.000 0.000 0.000 0.030 0.000 0.000 0.000 0.000 0.000 0.000 0.038 0.000 0.022 0.000 0.000 0.001 0.009 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.032 0.020 0.019 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.013 0.048 0.004 0.114 0.000 0.000 0.008 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.045 0.040 0.000 0.093 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.072
- 0. 027 0.000 0.098
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.020 0.041 0.009 0.005 0.003 0.018 0.004 0.000 0.004 0.033 0.000 0.009 0.000 0.130 0.114 0.004 0.394 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS B OF GROUND LEVEL STABILITY CLASS B 2111.000 233.630 18.530 8.320 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY
= 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/02/06 E-128
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2012 -
DEC 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.010 0.003 0.003 0.000 0.000 0.000 0.000 0.000 0.000 0.025 0.000 0.000 0.000 0.006 0.000 0.000 0.000 0.002 0.034 0.009 0.007 0.001 0.003 0.000 0.000 0.000 0.063 0.013 0.022 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.011 0.000 0.003 0.003 0.061 0.041 0.014 0.002 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.000 0.030 0.072 0.070 0.237 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.018 0.016 0.000 0.034 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.019 0.000 0.019
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.054 0.036 0.002 0.006 0.000 0.000 0.009 0.013 0.037 0.012 0.016 0.009 0.014 0.048 0.109 0.073 0.439 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS GROUND LEVEL RELEASE STABILITY CLASS C GROUND LEVEL STABILITY CLASS C 2111.000 233.630 47.060 9.260 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/02/06 E-129
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2012 -
DEC 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.003 0.018 0.047 0.031 0.047 0.059 0.015 0.001 0.011 0.000 0.000 0.000 0.232 0.027 0.026 0.014 0.006 0.031 0.044 0.055 0.079 0.117 0.066 0.012 0.030 0.040 0.013 0.004 0.013 0.578 0.085 0.047 0.022 0.008 0.000 0.017 0.000 0.000 0.036 0.018 0.009 0.013 0.042 0.019 0.029 0.117 0.461 0.129 0.070 0.080 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.069 0.159 0.185 0.176 0.875 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.187 0.367 0.426 0.019 1.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.044 0.482 0.062 0.000 0.587
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.241 0.143 0.116 0.013 0.034 0.079 0.102 0.110 0.200 0.144 0.036 0.053 0.392 1.039 0.706 0.325 3.734 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS D OF GROUND LEVEL STABILITY CLASS D 2111.000 233.630 784.020 78.820 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/02/06 E-130
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2012 -
DEC 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 0.000 0.000 0.000 0.000 0.004 0.001 0.000 0.000 0.001 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.006 0.019 0.022 0.018 0.022 0.058 0.052 0.114 0.066 0.298 0.090 0.072 0.036 0.019 0.004 0.008 0.024 0.923 0.062 0.030 0.059 0.064 0.047 0.126 0.023 0.086 0.483 0.119 0.039 0.030 0.028 0.023 0.011 0.114 1.346 0.028 0.043 0.023 0.027 0.008 0.037 0.000 0.000 0.204 0.009 0.020 0.024 0.032 0.018 0.036 0.081 0.590 0.018 0.048 0.030 0.026 0.000 0.039 0.038 0.000 0.047 0.000 0.000 0.000 0.025 0.035 0.067 0.074 0.448 0.000 0.000 0.017 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.129 0.000 0.156 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.127 0.143 0.147 0.139 0.117 0.256 0.175 0.152 1.034 0.218 0.132 0.090 0.105 0.090 0.252 0.293 3.468 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS E OF GROUND LEVEL STABILITY CLASS E 2111.000 233.630 719.110 73.220 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/02/06 E-131
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2012 -
DEC 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.013 0.009 0.003 0.001 0.002 0.003 0.016 0.012 0.011 0.000 0.003 0.000 0.000 0.000 0.000 0.000 0.073 0.092 0.062 0.072 0.090 0.083 0.090 0.111 0.123 0.101 0.015 0.009 0.006 0.011 0.000 0.007 0.050 0.922 0.148 0.127 0.074 0.034 0.027 0.032 0.000 0.115 0.147 0.015 0.000 0.000 0.005 0.006 0.000 0.061 0.790 0.018 0.042 0.052 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.007 0.001 0.022 0.144 0.000 0.008 0.019 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.017 0.000 0.000 0.000 0.009 0.000 0.052 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.271 0.248 0.220 0.126 0.111 0.124 0.126 0.250 0.260 0.030 0.029 0.006 0.016 0.013 0.017 0.133 1.980 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS F OF GROUND LEVEL STABILITY CLASS F 2111.000 233.630 389.270 41.800 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY
= 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/02/06 E-132
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 1 OF 2 GROUND LEVEL RELEASE MODE OCT 1, 2012 -
DEC 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.012 0.003 0.027 0.020 0.005 0.003 0.009 0.000 0.002 0.000 0.000 0.013 0.000 0.000 0.004 0.005 0.103 0.069 0.045 0.045 0.029 0.031 0.023 0.007 0.014 0.000 0.009 0.000 0.000 0.000 0.000 0.000 0.024 0.294 0.054 0.094 0.052 0.007 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.002 0.011 0.221 0.000 0.002 0.021 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.010 0.000 0.000 0.000 0.000 0.006 0.039 0.000 0.000 0.011 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.011 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.135 0.144 0.156 0.056 0.036 0.026 0.015 0.014 0.002 0.009 0.010 0.013 0.000 0.000 0.006 0.046 0.668 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF GROUND LEVEL RELEASE OF STABILITY CLASS G OF GROUND LEVEL STABILITY CLASS G 2111.000 233.630 142.380 14.110 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 45.30 METERS WIND DIRECTION MEASURED AT 10.50 METER LEVEL WIND SPEED MEASURED AT 10.50 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/02/06 E-133
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2012 -
DEC 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.044 0.000 0.000 0.000 0.000 0.000 0.000 0.044 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.038 0.038 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.076 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.038 0.038 0.044 0.000 0.000 0.000 0.000 0.000 0.000 0.120 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS A OF ELEVATED STABILITY CLASS A 2111.000 1877.370 10.630 2.530 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/02/06 E-134
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2012 -
DEC 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000
- 0. 000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.045 0.092 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.228 0.000 0.040 0.000 0.000 0.000 0.000 0.044 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.084 0.000 0.039 0.000 0.000 0.000 0.000 0.000 0.038 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.077 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.000 0.079 0.000 0.000 0.000 0.000 0.137 0.083 0.140 0.045 0.000 0.000 0.000 0.000 0.000 0.000 0.484 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS B OF ELEVATED STABILITY CLASS B 2111.000 1877.370 18.530 10.210 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/02/06 E-135
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2012 -
DEC 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.237 0.047 0.189 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.521 0.000 0.000 0.000 0.000 0.000 0.047 0.138 0.092 0.046 0.139 0.000 0.047 0.000 0.000 0.000 0.000 0.510 0.040 0.000 0.000 0.000 0.000 0.000 0.000 0.040 0.169 0.087 0.000 0.000 0.000 0.000 0.000 0.042 0.377 0.078 0.000 0.000 0.000 0.000 0.000 0.039 0.000 0.000 0.000 0.000 0.078 0.039 0.039 0.000 0.000 0.274 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.088 0.021 0.000 0.108
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.118 0.000 0.000 0.000 0.000 0.047 0.414 0.180 0.405 0.225 0.047 0.126 0.039 0.127 0.021 0.042 1.791 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS C OF ELEVATED STABILITY CLASS C 2111.000 1877.370 47.060 37.800 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/02/06 E-136
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2012 -
DEC 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.047 0.000 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.095 0.047 0.000 0.000 0.284 0.000 0.095 0.095 0.047 0.095 0.142 0.805 0.663 0.426 0.332 0.426 0.379 0.237 0.047 0.095 0.047 3.932 0.284
- 0. 663 0.284 0.142 0.095 0.000 1.137 0.474 0.332 0.284 0.237 0.332 0.332 0.284 0.189 0.047 5.116 0.498 1.041 0.365 0.181 0.090 0.046 0.646 0.231 0.506 0.226 0.137 0.135 0.630 0.458 0.407 0.312 1.568 1.338 0.590 0.253 0.000 0.123 0.546 0.212 0.779 0.414 0.502 0.247 0.584 1.001 1.431 1.419 0.661 0.196 0.039 0.000 0.000 0.000 0.542 0.385 0.504 0.268 0.114 0.117 0.232 0.541 1.147 0.583 5.327 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.189 0.280 0.022 0.000 0.034 0.099 0.710 0.398 0.036 1.769
>=24. 5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.016 0.000 0.000 0.000 0.000 0.020 0.024 0.000 0.000 0.061 TOTAL 3.012 3.332 1.421
- 0. 623 0.327 0.312 3.676 2.217 2.827 1.546 1.416 1.243 2.228 3.112 3.667 2.445 33.406 5.910 11.007 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF OF OF OF VALID OBSERVATIONS ELEVATED RELEASES STABILITY CLASS D ELEVATED STABILITY CLASS D 2111.000 1877.370 784.020 705.200 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/02/06 E-137
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2012 -
DEC 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.095 0.047 0.047 0.095 0.095 0.189 0.237 0.047 0.095 0.095 0.000 0.000 0.047 0.047 0.047 0.095 0.095 1.279 0.142 0.095 0.142 0.332 0.189 0.379 0.663 0.379 0.379 0.237 0.379 0.189 0.142 0.047 0.095 0.047 3.837 0.320 0.403 0.316 0.137 0.233 0.419 0.647 0.721 0.597 0.277 0.318 0.185 0.461 0.090 0.181 0.366 5.671 0.917 1.559
- 0. 672 0.252 0.296 0.420 0.991 1.975 2.487 0.782 0.591 0.125 0.410 0.374 0.580 0.957 13.387 0.000 0.196 0.117 0.117 0.077 0.038 0.461 1.194 1.460 0.463 0.114 0.079 0.000 0.000 0.348 0.233 4.896 0.000 0.000 0.000 0.000 0.000 0.037 0.061
- 0. 608 0.512 0.124 0.031 0.000 0.000 0.031 0.000 0.000 1.405
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.009 0.017 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 1.426 2.300 1.342 0.933 0.984 1.577 2.880 4.988 5.530 1.883 1.433 0.625 1.061 0.638 1.298 1.698 0.026 30.596 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS E OF ELEVATED STABILITY CLASS E 2111.000 1877.370 719.110 645.890 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/02/06 E-138
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2012 -
DEC 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.047 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.237 0.095 0.142 0.047 0.142 0.047 0.189 0.189 0.189 0.142 0.047 0.047 0.142 0.000 0.047 0.047 0.142 1.658 0.000 0.142 0.142 0.189 0.047 0.189 0.332 0.332 0.189 0.189 0.142 0.142 0.142 0.142 0.189 0.000 2.511 0.182 0.134 0.321 0.270 0.185 0.505 1.004 1.182 0.493 0.456 0.140 0.047 0.047 0.092 0.137 0.132 5.327 0.382 1.160 0.169 0.169 0.042 0.126 1.019 1.243 1.248 0.215 0.000 0.000 0.000 0.000 0.128 0.128 6.030 0.000 0.156 0.000 0.000 0.000 0.000 0.117 0.273 0.117 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.664 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.034 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.034
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.659 1.734 0.680 0.771 0.322 1.057 2.710 3.254 2.236
- 0. 908 0.377 0.378 0.189 0.281 0.502 0.402 0.000 16.460 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS F OF ELEVATED STABILITY CLASS F 2111.000 1877.370 389.270 347.470 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/02/06 E-139
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT SPLIT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT PART 2 OF 2 ELEVATED RELEASE MODE OCT 1, 2012 DEC 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 7.5-12.4 12.5-18.4 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.047 0.142 0.000 0.095 0.000 0.000 0.000 0.000 0.379 0.047 0.047 0.095 0.095 0.047 0.095 0.189 0.237 0.047 0.047 0.047 0.095 0.000 0.142 0.237 0.142 1.611 0.000 0.047 0.047 0.095 0.047 0.189 0.474 0.284 0.047 0.000 0.095 0.047 0.047 0.189 0.000 0.095 1.705 0.047 0.044 0.183 0.000 0.000 0.139 0.675 0.182 0.000 0.134 0.000 0.000 0.000 0.000 0.000 0.000 1.404 0.000 0.000 0.084 0.171 0.087 0.083 0.257 0.172 0.041 0.043 0.000 0.000 0.000 0.000 0.000 0.000 0.938 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.039 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 TOTAL 0.095 0.139 0.410 0.360 0.181 0.506 1.642
- 0. 962 0.183 0.367 0.142 0.237 0.047 0.332 0.237 0.237 6.076 TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS OF VALID OBSERVATIONS OF ELEVATED RELEASES OF STABILITY CLASS G OF ELEVATED STABILITY CLASS G 2111.000 1877.370 142.380 128.270 METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND DIRECTION MEASURED AT 45.74 METER LEVEL WIND SPEED MEASURED AT 45.74 METER LEVEL EFFLUENT VELOCITY = 12.60 M/S NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/02/06 E-140
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT BROWNS FERRY NUCLEAR PLANT 2012 METEOROLOGICAL DATA TABLE 9A JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES FIRST QUARTER E-141
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2012 -
MAR 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.142 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.190 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.095 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.285 18.5-24.4 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.237 0.142 0.095 0.047 0.000 0.000 0.000 0.000 0.000 0.522 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2107 11 11 2107 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 11.66 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/05/15 E-142
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2012 -
MAR 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.095 0.142 0.000 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.332 0.000 0.047 0.000 0.000 0.000 0.000 0.047 0.047 0.047 0.000 0.095 0.047 0.000 0.000 0.000 0.000 0.332 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.142 0.190 0.047 0.095 0.000 0.095 0.095 0.000 0.000 0.000 0.000 0.712 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2107 15 15 2107 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2012/05/15 MEAN WIND SPEED = 12.10 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-143
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2012 -
MAR 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4
>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.095 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.237 0.000 0.000 0.000 0.000 0.000 0.142 0.047 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.285 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.047 0.000 0.047 0.000 0.047 0.047 0.047 0.000 0.047 0.380 0.190 0.000 0.000 0.000 0.000 0.095 0.142 0.000 0.000 0.047 0.095 0.000 0.142 0.095 0.000 0.047 0.854 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.190 0.047 0.142 0.475 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.047 0.000 0.190 0.190 0.000 0.000 0.000 0.000 0.332 0.332 0.095 0.095 0.142 0.332 0.047 0.190 0.427 0.095 0.237 2.515 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM 2107 53 53 2107 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 14.30 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/05/15 E-144
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2012 -
MAR 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 18.5-24.4
>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.142 0.047 0.000 0.000 0.000 0.095 0.142 0.047 0.142 0.285 0.190 0.190 0.047 0.047 0.000 1.424 0.190 0.142 0.095 0.047 0.000 0.427 0.332 0.332 0.095 0.095 0.142 0.190 0.237 0.190 0.237 0.190 2.943 0.190 0.285 0.237 0.237 0.190 0.190 0.190 0.570 0.095 0.142 0.237 0.285 0.427 0.380 0.285 0.142 4.082 0.854 0.997 0.807 0.427 0.190 0.380 0.142 0.427 0.522 0.285 0.427 0.854 0.475 1.851 0.332 0.712 9.682 0.380 0.380 0.095 0.047 0.047 0.380 0.237 0.095 0.237 0.332 0.190 0.617 0.759 0.949 0.759 1.044 6.550 0.570 0.332 0.000 0.000 0.000 0.190 0.570 0.427 0.095 0.190 0.095 0.427 0.664 1.092 0.997 0.759 6.407 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.095 0.047 0.142 0.000 0.000 0.285 0.427 0.332 0.095 2.278 2.278 1.281 0.759 0.427 1.566 1.614 2.088 1.139 1.376 1.376 2.563 3.037 4.936 2.990 2.943 1.519 32.653 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 12.76 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS 2107 688 688 2107 0
DATE PRINTED: 2012/05/15 E-145
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2012 -
MAR 31, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.000 0.000 0.095 0.047 0.095 0.000 0.000 0.047 0.000 0.095 0.190 0.047 0.095 0.095 0.000 0.047 0.000 0.095 0.047 0.902 0.000 0.047 0.000 0.142 0.142 0.142 0.142 0.047 0.427 0.095 0.190 0.380 0.047 0.190 0.142 0.095 2.231 0.095 0.190 0.380 0.095 0.095 0.237 0.475 0.475 0.332 0.332 0.475 0.427 0.047 0.142 0.237 0.000 0.807 0.854
- 0. 617
- 0. 522 0.142 0.522 0.854 0.759 1.756 0.807 1.519 0.712 0.854 0.427 0.522 0.807 0.712 0.712
- 0. 902 0.190 0.332 0.902 1.281 1.709 1.756 1.044 0.807 0.285 0.237 0.190 0.617 1.281 0.047 0.332 0.142 0.000 0.000 0.617 2.468 1.804 1.187 1.614 0.332 0.237 0.190 0.095 0.617 0.285 9.967 0.047 0.000 0.000 0.000 0.000 0.047 0.427 0.570 1.092 0.712 0.142 0.000 0.047 0.000 0.000 0.047 1.756 2.231 2.041 0.949 0.759 2.468 5.743 5.553 6.597 4.699 3.607 2.041 1.471 1.092 2.231 2.563 SUBTOTAL 4.034 12.482 12.957 3.132 45.800 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2107 965 965 2107 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2012/05/15 MEAN WIND SPEED = 14.38 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-146
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2012 -
MAR 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.000 0.047 0.000 0.000 0.000 0.047 0.095 0.000 0.000 0.285 0.000 0.000 0.000 0.095 0.142 0.000 0.047 0.000 0.047 0.000 0.000 0.095 0.095 0.047 0.047 0.000 0.617 0.095 0.000 0.047 0.047 0.142 0.095 0.047 0.000 0.237 0.190 0.000 0.000 0.047 0.190 0.047 0.047 1.234 0.427 0.190 0.380 0.047 0.190 0.047 0.237 0.047 0.617 0.902 0.664 0.237 0.095 0.095 0.285
- 0. 142 4.604 0.427 0.617 0.237 0.095 0.237 0.190 0.617 1.566 1.661 0.712 0.475 0.000 0.095 0.000 0.000 0.047 6.977 0.000 0.190 0.095 0.000 0.095 0.000 0.332 0.949 0.380 0.047 0.000 0.000 0.000 0.000 0.000 0.000 2.088 0.000 0.000 0.000 0.000 0.000 0.000 0.332 0.190 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.949 0.997 0.759 0.332 0.807 0.332 1.661 2.753 3.037 1.851 1.139 0.380 0.380 0.427 0.380 0.237 0.522 16.421 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2107 346 346 2107 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 13.56 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/05/15 E-147
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT JAN 1, 2012 -
MAR 31, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.095 0.000 0.000 0.047 0.142 0.142 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.427 0.000 0.047 0.142 0.000 0.000 0.000 0.000 0.047 0.237 0.142 0.000 0.047 0.000 0.000 0.000 0.000 0.664 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.190 0.142 0.190 0.000 0.000 0.095 0.285 0.142 0.047 0.095 0.000 0.095 0.047 0.000 1.376 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2107 29 29 2107 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2012/05/15 MEAN WIND SPEED = 12.17 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-148
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT BROWNS FERRY NUCLEAR PLANT 2012 METEOROLOGICAL DATA TABLE 9B JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES SECOND QUARTER E-149
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2012 -
JUN 30, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.138 0.138 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.321 0.000 0.000 0.000 0.000 0.000 0.000 0.138 0.413 0.092 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.688 0.000 0.000 0.000 0.000 0.000 0.000 0.505 0.275 0.413 0.183 0.000 0.000 0.000 0.000 0.000 0.000 1.376 0.000 0.275 0.000 0.000 0.000 0.000 0.000 0.183 0.229 0.000 0.000 0.000 0.000 0.046 0.092 0.000 0.826 0.000 0.046 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.092 0.000 0.321 0.000 0.000 0.000 0.000 0.826 1.009 0.734 0.183 0.092 0.000 0.000 0.046 0.092 0.092 3.394 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2180 74 74 2180 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2012/08/20 MEAN WIND SPEED = 10.89 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-150
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2012 -
JUN 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.092 0.183 0.046 0.092 0.046 0.046 0.092 0.000 0.046 0.000 0.688 0.000 0.000 0.000 0.046 0.000 0.000 0.505 0.092 0.046 0.138 0.000 0.000 0.046 0.046 0.000 0.000 0.917 0.138 0.183 0.092 0.000 0.000 0.183 0.321 0.046 0.321 0.046 0.000 0.000 0.000 0.046 0.138 0.046 1.560 0.046 0.092 0.000 0.000 0.000 0.000 0.092 0.092 0.138 0.092 0.092 0.000 0.000 0.000 0.092 0.138 0.872 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.046 0.046 0.229 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.229 0.321 0.092 0.046 0.000 0.229 1.055 0.413 0.550 0.413 0.138 0.046 0.138 0.092 0.321 0.275 4.358 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL 2180 95 95 2180 0
DATE PRINTED: 2012/08/20 MEAN WIND SPEED 9.92 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-151
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2012 -
JUN 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED (MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000
>=24.5 TOTAL 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.092 0.000 0.092 0.000 0.000 0.046 0.000 0.000 0.000 0.275 0.000 0.000 0.000 0.000 0.000 0.046 0.413 0.229 0.183 0.046 0.138 0.321 0.275 0.000 0.000 0.046 1.697 0.000 0.000 0.000 0.000 0.000 0.092 0.183 0.046 0.046 0.000 0.092 0.138 0.138 0.183 0.046 0.000 0.963 0.505 0.459 0.000 0.000 0.000 0.000 0.183 0.138 0.046 0.229 0.183 0.138 0.138 0.183 0.046 0.092 2.339 0.229 0.183 0.046 0.000 0.000 0.046 0.138 0.046 0.183 0.000 0.092 0.092 0.000 0.092 0.138 0.550 1.835 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.229 0.046 0.459 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.780 0.688 0.046 0.000 0.000 0.183 0.963 0.596 0.459 0.367 0.505 0.688 0.596 0.505 0.459 0.734 7.569 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2180 165 165 2180 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED =
9.85 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/08/20 E-152
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2012 -
JUN 30, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.046 0.000 0.000 0.046 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.183 0.092 0.092 0.046 0.046 0.046 0.046 0.550 0.688 0.367 0.138 0.321 0.321 0.183 0.000 0.183 0.000 3.119 0.138 0.046 0.092 0.000 0.138 0.367 0.275 0.367 0.459 0.229 0.505 0.780 0.688 0.275 0.275 0.138 4.771 0.183 0.367 0.046 0.092 0.046 0.183 0.275 0.138 0.367 0.321 0.505 0.275 0.459 0.550 0.642 0.321 4.771 1.239 1.055 0.321 0.275 0.229 0.550 0.734 0.505 0.550 0.596 0.734 0.734 0.917 1.835 1.009 1.101 12.385 1.055 0.642 0.046 0.000 0.000 0.550 1.422 1.101 0.688 0.367 0.505 0.642 0.321 0.459 0.642 0.688 9.128 0.367 0.000 0.000 0.000 0.000 0.046 0.321 0.550 0.138 0.046 0.000 0.000 0.000 0.046 0.229 0.183 1.927 0.092 0.000 0.000 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 3.165 2.202 0.596 0.413 0.459 1.789 3.624 3.349 2.615 1.697 2.569 2.752 2.615 3.165 2.982 2.431 0.138 36.422 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2180 794 794 2180 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2012/08/20 MEAN WIND SPEED
- 9. 92 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-153
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2012 -
JUN 30, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.000 0.046 0.046 0.000 0.092 0.046 0.000 0.092 0.138 0.046 0.000 0.229 0.138 0.046 0.183 0.092 1.193 0.229 0.046 0.046 0.046 0.000 0.183 0.092 0.183 0.321 0.275 0.229 0.550 0.138 0.046 0.183 0.092 2.661 0.321 0.046 0.046 0.046 0.046 0.092 0.183 0.275 0.688 0.413 0.505 0.275 0.092 0.229 0.046 0.275 0.688 0.688 0.367 0.183 0.321 0.734 0.872 1.284 0.872 0.734 0.780 0.413
- 0. 642 0.596 0.367 0.688 1.101 1.239 0.413 0.138 0.046 0.229 0.826 1.239 0.734 0.321 0.550 0.046 0.505 0.183 0.229 0.642 8.440 0.092 0.642 0.321 0.000 0.000 0.000 0.138 0.550 0.550 0.046 0.000 0.000 0.000 0.000 0.138 0.183 2.661 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.138 0.000 0.000 0.000 0.000 0.000 0.000 0.000 2.431 2.706 1.239 0.413 0.505 1.284 2.110 3.670 3.486 1.881 2.064 1.514 1.514 1.101 1.147 1.972 SUBTOTAL 3.578 10.229 0.183 29.037 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2180 633 633 2180 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 11.32 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/08/20 E-154
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2012 -
JUN 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL 0.046 0.000 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.046 0.000 0.046 0.000 0.000 0.046 0.046 0.046 0.092 0.000 0.138 0.138 0.000 0.046 0.000 0.046 0.688 0.046 0.092 0.000 0.046 0.138 0.046 0.321 0.092 0.092 0.046 0.183 0.092 0.046 0.138 0.000 0.138 1.514 0.229 0.183 0.046 0.046 0.092 0.229 0.046 0.138 0.092 0.183 0.229 0.046 0.092 0.321 0.183 0.275 2.431 0.183 0.275 0.321 0.275 0.275 0.138 0.596 0.688 0.550 0.550 0.183 0.046 0.092 0.183 0.138 0.046 4.541 0.550 0.550 0.826 0.275 0.046 0.183 0.046 0.138 0.367 0.321 0.046 0.046 0.183 0.092 0.000 0.229 3.899 0.138 0.596 0.092 0.000 0.000 0.000 0.000 0.092 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.963 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 1.239 1.697 1.330 0.642 0.596 0.642 1.055 1.193 1.193 1.147 0.780 0.367 0.413 0.780 0.321 0.734 0.000 14.128 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2180 308 308 2180 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2012/08/20 MEAN WIND SPEED = 10.54 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-155
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT APR 1, 2012 -
JUN 30, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.092 0.000 0.046 0.046 0.092 0.000 0.092 0.183 0.046 0.092 0.000 0.092 0.046 0.000 0.000 0.000 0.046 0.780 0.000 0.046 0.000 0.138 0.138 0.092 0.046 0.000 0.000 0.046 0.000 0.000 0.000 0.000 0.000 0.046 0.550 0.046 0.000 0.046 0.000 0.000 0.092 0.046 0.000 0.000 0.046 0.046 0.000 0.046 0.000 0.046 0.321 0.734 0.046 0.046 0.092 0.321 0.321 0.138 0.000 0.138 0.046 0.046 0.046 0.000 0.000 0.046 0.046 0.092 1.422 0.229 0.367 0.229 0.138 0.092 0.046 0.000 0.000 0.046 0.046 0.000 0.000 0.000 0.000 0.000 0.046 1.239 0.000 0.138 0.138 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.275 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.321 0.642 0.550 0.734 0.596 0.459 0.275 0.183 0.183 0.183 0.183 0.046 0.046 0.046 0.092 0.550 5.092 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2180 111 2180 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED =
9.52 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/08/20 E-156
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT BROWNS FERRY NUCLEAR PLANT 2012 METEOROLOGICAL DATA TABLE 9C JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES THIRD QUARTER E-157
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT JUL 1, 2012 -
SEP 30, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.102 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.255 0.000 0.000 0.051 0.153 0.000 0.000 0.000 0.000 0.511 0.000 0.000 0.000 0.000 0.000 0.102 0.511 0.153 0.204 0.409 0.204 0.051 0.051 0.000 0.000 0.000 1.685 0.000 0.000 0.000 0.000 0.000 0.000 0.102 0.000 0.051 0.153 0.000 0.000 0.000 0.000 0.000 0.000 0.306 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.102
- 0. 664 0.409 0.306 0.562 0.255 0.255 0.051 0.000 0.000 0.000 2.605 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 1958 51 51 1958 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED =
9.70 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/11/19 E-158
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT JUL 1, 2012 -
SEP 30, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.102 0.051 0.000 0.102 0.102 0.051 0.000 0.000 0.000 0.000 0.409 0.000 0.000 0.000 0.000 0.000 0.000 0.102 0.051 0.000 0.051 0.051 0.204 0.102 0.000 0.000 0.000 0.562 0.000 0.000 0.000 0.000 0.000 0.051 0.153 0.051 0.358 0.204 0.102 0.051 0.460 0.102 0.051 0.000 1.583 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.051 0.102 0.153 0.051 0.000 0.000 0.102 0.051 0.000 0.562 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.102 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.460 0.204 0.511 0.511 0.306 0.306 0.562 0.204 0.102 0.000 3.218 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 1958 63 63 1958 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2012/11/19 MEAN WIND SPEED 9.74 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-159
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JUL 1, 2012 -
SEP 30, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.102 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.153 0.000 0.000 0.000 0.000 0.051 0.000 0.153 0.153 0.255 0.204 0.153 0.153 0.204 0.000 0.000 0.000 1.328 0.000 0.000 0.000 0.000 0.000 0.000 0.255 0.000 0.000 0.051 0.204 0.102 0.511 0.102 0.051 0.000 1.277 0.204 0.153 0.000 0.000 0.000 0.051 0.204 0.051 0.409 0.153 0.358 0.204 0.306 0.460 0.000 0.000 2.554 0.000 0.000 0.000 0.000 0.000 0.051 0.306 0.153 0.204 0.102 0.000 0.000 0.000 0.102 0.204 0.000 1.124 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.051 0.051 0.000 0.000 0.000 0.000 0.051 0.204 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.204 0.153 0.000 0.000 0.051 0.102 0.970 0.511 0.868 0.562 0.766 0.460 1.021 0.664 0.255 0.051 6.639 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 1958 130 130 1958 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2012/11/19 MEAN WIND SPEED 9.16 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-160
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JUL 1, 2012 -
SEP 30, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.102 0.153 0.102 0.255 0.153 0.153 0.153 0.204 0.409 0.613 0.460 0.409 0.358 0.306 0.102 0.051 0.102 3.984 0.204 0.204 0.102 0.409 0.102 0.204 0.511 0.613 0.715 0.919 0.409 0.562 0.562 0.460 0.204 0.306 6.486 0.664 0.051 0.255 0.153 0.102 0.153 0.460 0.409 0.766 1.021 0.868 0.766 1.124 0.511 0.204 0.306 0.613 0.562 0.255 0.204 0.102 0.409 1.175 1.685 2.247 2.094 1.073 1.021 2.298 1.532 0.868 0.409 0.000 0.051 0.153 0.000 0.000 0.460 1.124 1.430 1.073
- 0. 664 0.409 0.051 0.306 0.102 0.102 0.204 6.129 0.000 0.051 0.051 0.000 0.000 0.153 0.817 0.358 0.102 0.102 0.051 0.000 0.000 0.051 0.051 0.000 1.788 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.051 1.634 1.021 1.073 0.919 0.460 1.532 4.341 4.903 5.516 5.363 3.218 2.758 4.597 2.758 1.481 1.328 42.901 7.814 16.547 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 1958 840 840 1958 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED =
8.84 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2012/11/19 E-161
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT JUL 1, 2012 -
SEP 30, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.051 0.000 0.000 0.000 0.051 0.153 0.051 0.153 0.102 0.153 0.153 0.000 0.051 0.204 0.358 0.358 0.102 0.255 0.000 0.102 0.051 0.153 2.247 0.153 0.153 0.204 0.000 0.051 0.204 0.358 0.409 0.255 0.153 0.102 0.255 0.358 0.153 0.204 0.000 3.013 0.255 0.306 0.204 0.153 0.102 0.051 0.409
- 0. 664 0.460 0.255 0.358 0.204 0.358 0.511 0.102 0.204 0.306 0.562 0.358 0.306 0.562 0.919 1.532 1.328 0.817 0.817 0.919 0.715 1.685 1.021 0.153 0.460 0.153 0.715 0.409 0.102 0.409 0.970 0.460 0.204 0.715 0.409 0.255 0.102 0.358 0.051 0.102 0.255 5.669 0.000 0.051 0.102 0.051 0.000 0.102 0.000 0.051 0.000 0.000 0.051 0.000 0.000 0.000 0.051 0.000 0.460 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.919 1.941 1.379 0.766 1.277 2.247 2.809 2.860 2.605 2.043 1.788 1.583 2.758 1.839 0.664 1.124 SUBTOTAL 4.597 12.462 0.000 28.601 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 1958 560 560 1958 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2012/11/19 MEAN WIND SPEED =
9.24 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-162
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT JUL 1, 2012 -
SEP 30, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.051 0.051 0.000 0.102 0.153 0.153 0.051 0.000 0.051 0.051 0.000 0.051 0.000 0.766 0.051 0.051 0.051 0.051 0.000 0.000 0.358 0.102 0.102 0.306 0.000 0.000 0.102 0.102 0.000 0.102 1.379 0.153 0.000 0.102 0.204 0.153 0.204 0.255 0.204 0.153 0.051 0.000 0.000 0.000 0.102 0.051 0.102 1.736 0.153 0.306 0.409 0.204 0.102 0.460 0.970 0.511 0.409 0.204 0.102 0.102 0.051 0.051 0.000 0.051 4.086 0.358 0.562 0.204 0.460 0.102 0.306 0.409 0.051 0.102 0.102 0.000 0.000 0.000 0.000 0.000 0.051 2.707 0.000 0.306 0.102 0.051 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.460 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.715 1.226 0.919 1.021 0.409 0.970 2.094 1.021 0.919 0.715 0.102 0.153 0.204 0.255 0.102 0.306 0.000 11.134 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F TOTAL HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS TOTAL HOURS CALM 1958 218 218 1958 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2012/11/19 MEAN WIND SPEED 9.90 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-163
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT JUL 1, 2012 -
SEP 30, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.000 0.000 0.000 0.051 0.000 0.000 0.051 0.051 0.051 0.000 0.000 0.000 0.000 0.255 0.153 0.051 0.051 0.000 0.051 0.000 0.051 0.153 0.153 0.102 0.051 0.204 0.051 0.102 0.051 0.000 1.226 0.000 0.102 0.102 0.000 0.000 0.000 0.000 0.051 0.051 0.255 0.153 0.051 0.000 0.000 0.000 0.000 0.766 0.000 0.000 0.000 0.051 0.051 0.102 0.051 0.051 0.102 0.102 0.000 0.051 0.000 0.000 0.000 0.000 0.562 0.000 0.051 0.306 0.358 0.153 0.000 0.000 0.000 0.204 0.102 0.000 0.000 0.000 0.000 0.000 0.000 1.175 0.000 0.204 0.358 0.102 0.102 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.766 0.000 0.051 0.102 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.153 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.204 0.460 0.919 0.511 0.358 0.102 0.153 0.255 0.511 0.613 0.255 0.358 0.051 0.102 0.051 0.000 4.903 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS G TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 1958 96 96 1958 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2012/11/19 MEAN WIND SPEED =
7.24 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-164
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT BROWNS FERRY NUCLEAR PLANT 2012 METEOROLOGICAL DATA TABLE 9D JOINT FREQUENCY DISTRIBUTION IN PERCENT FOR ELEVATED RELEASES FOURTH QUARTER E-165
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS A (DELTA T<=-1.9 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2012 -
DEC 31, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.142 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS A TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS A OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2111 3
3 2111 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2013/02/06 MEAN WIND SPEED = 16.60 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-166
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS B
(-1.9< DELTA T<=-1.7 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2012 -
DEC 31, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.189 0.000 0.047 0.000 0.000 0.000 0.000 0.047 0.000 0.047 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.189 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.142 0.142 0.095 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.521 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS B TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS B OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2111 11 11 2111 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2013/02/06 MEAN WIND SPEED =
9.31 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-167
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS C
(-1.7< DELTA T<=-1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2012 -
DEC 31, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.142 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.237 0.000 0.000 0.000 0.000 0.000 0.047 0.189 0.095 0.047 0.142 0.000 0.047 0.000 0.000 0.000 0.000 0.568 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.047 0.189 0.142 0.000 0.000 0.000 0.000 0.000 0.047 0.521 0.142 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.000 0.000 0.095 0.000 0.047 0.000 0.000 0.379 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.142 0.000 0.000 0.189 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.095 0.142 0.000 0.000 0.000 0.000 0.142 0.284 0.189 0.379 0.332 0.047 0.189 0.000 0.284 0.000 0.047 2.037 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS C TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS C OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2111 43 43 2111 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2013/02/06 MEAN WIND SPEED = 10.91 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-168
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS D
(-1.5< DELTA T<=-0.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2012 -
DEC 31, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.095 0.047 0.000 0.000 0.047 0.237 0.000 0.142 0.095 0.047 0.095 0.142 0.426 0.568 0.379 0.379 0.379 0.189 0.332 0.095 0.095 0.000 3.363 0.237 0.237 0.237 0.047 0.095 0.426 0.711 0.426 0.189 0.189 0.142 0.284 0.426 0.142 0.095 0.047 3.932 0.379 0.853 0.284 0.000 0.047 0.189 0.379 0.379 0.284 0.095 0.047 0.000 0.189 0.237 0.426 0.047 1.374 1.705 0.853 0.332 0.095 0.095 0.379 0.426 1.090 0.474 0.616 0.332 1.184 1.326 1.042 1.611 1.516 0.474 0.142 0.047 0.000 0.095 0.663 0.474 0.805 0.332 0.332 0.237 0.379 0.568 1.279 0.900 8.243 0.047 0.047 0.000 0.000 0.000 0.000 0.142 0.284 0.426 0.189 0.142 0.142 0.189 1.374 0.853 0.047 3.884 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.284 0.142 0.000 0.047 0.047 0.568 0.853 0.095 0.000 2.037 3.553 3.458 1.611 0.474 0.332 0.995 2.700 2.842 3.316 1.658 1.705 1.326 3.316 4.595 3.884 2.700 38.465 3.837 12.932 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS D TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS D OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2111 812 812 2111 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2013/02/06 MEAN WIND SPEED = 11.54 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-169
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS E
(-0.5< DELTA T<= 1.5 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2012 -
DEC 31, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.095 0.000 0.000 0.047 0.095 0.000 0.142 0.189 0.000 0.095 0.047 0.000 0.000 0.047 0.047 0.047 0.095 0.853 0.047 0.000 0.000 0.047 0.189 0.095 0.142 0.000 0.142 0.000 0.047 0.000 0.047 0.047 0.000 0.000 0.805 0.095 0.095 0.142 0.142 0.095 0.095 0.474 0.332 0.332 0.189 0.142 0.095 0.095 0.000 0.047 0.095 0.521 1.326 0.426 0.474 0.189 0.426 0.568 2.842 2.795 0.947 0.521 0.379 0.568 0.426 0.426 0.521 0.805 1.326 0.853 0.142 0.237 0.142 0.616 1.611 2.321 1.042 0.711 0.332 0.237 0.426 0.663 0.805 0.000 0.142 0.095 0.095 0.047 0.047 0.426 1.090 1.374 0.379 0.142 0.000 0.000 0.000 0.095 0.142 4.074 0.000 0.000 0.000 0.000 0.000 0.047 0.189 0.616 0.095 0.047 0.000 0.000 0.000 0.047 0.000 0.000 1.468 2.890 1.563 0.995 0.758 0.995 2.605 6.490 7.200 2.653 1.563 0.805 0.995 1.042 1.279 1.658 SUBTOTAL 2.463 13.359 12.269 1.042 34.960 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS E TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS E OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2111 738 738 2111 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL DATE PRINTED: 2013/02/06 MEAN WIND SPEED = 12.90 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS E-170
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS F
( 1.5< DELTA T<= 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2012 -
DEC 31, 2012 WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.000 0.000 0.000 0.047 0.000 0.000 0.095 0.000 0.000 0.047 0.095 0.047 0.000 0.095 0.047 0.047 0.000 0.095 0.095 0.047 0.711 0.000 0.047 0.000 0.095 0.142 0.000 0.189 0.237 0.142 0.000 0.047 0.000 0.000 0.000 0.095 0.000 0.995 0.000 0.000 0.189 0.000 0.095 0.284 0.284 0.189 0.189 0.189 0.047 0.047 0.000 0.000 0.237 0.000 1.753 0.142 0.284 0.426 0.379 0.142 0.189 0.521 1.895 2.463 0.521 0.332 0.284 0.047 0.095 0.332 0.284 8.337 0.379 1.326 0.332 0.189 0.047 0.000 0.095 1.137 1.374 0.284 0.189 0.000 0.000 0.000 0.000 0.095 5.448 0.000 0.237 0.000 0.000 0.000 0.000 0.000 0.095 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.332 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.521 1.895 1.042 0.663 0.426 0.521 1.184
- 3. 600 4.169 1.090 0.711 0.379 0.047 0.189 0.758 0.426 0.000 17.622 TOTAL HOURS OF VALID STABILITY OBSERVATIONS TOTAL HOURS OF STABILITY CLASS F TOTAL TOTAL TOTAL HOURS HOURS HOURS OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS F OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2111 372 372 2111 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED = 10.67 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/02/06 E-171
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT JOINT PERCENTAGE FREQUENCIES OF WIND SPEED BY WIND DIRECTION FOR STABILITY CLASS G (DELTA T > 4.0 C/100 M)
BROWNS FERRY NUCLEAR PLANT OCT 1, 2012 -
DEC 31, 2012 WIND DIRECTION N
NNE NE ENE E
WNW NW NNW SUBTOTAL WIND SPEED(MPH) 0.6-1.4 1.5-3.4 3.5-5.4 5.5-7.4 CALM 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 7.5-12.4 12.5-18.4 18.5-24.4
>=24.5 TOTAL 0.047 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.047 0.047 0.000 0.095 0.000 0.000 0.000 0.237 0.000 0.047 0.000 0.000 0.047 0.000 0.000 0.000 0.095 0.047 0.047 0.047 0.047 0.047 0.000 0.047 0.474 0.000 0.000 0.047 0.189 0.095 0.000 0.189 0.189 0.142 0.047 0.000 0.000 0.000 0.047 0.095 0.095 1.137 0.000 0.000 0.000 0.095 0.142 0.284 0.189 0.237 0.095 0.000 0.000 0.047 0.047 0.000 0.047 0.000 1.184 0.047 0.047 0.095 0.189 0.047 0.000 0.189 1.090 0.379 0.000 0.095 0.000 0.095 0.095 0.095 0.000 2.463 0.000 0.000 0.189 0.047 0.000 0.000 0.047 0.189 0.142 0.047 0.095 0.000 0.000 0.000 0.000 0.000 0.758 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.095 0.095 0.332 0.521 0.332 0.284 0.616 1.705 0.853 0.189 0.284 0.095 0.284 0.189 0.237 0.142 6.253 TOTAL TOTAL TOTAL TOTAL TOTAL HOURS HOURS HOURS HOURS HOURS OF VALID STABILITY OBSERVATIONS OF STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY CLASS G OF VALID WIND DIRECTION-WIND SPEED-STABILITY OBSERVATIONS CALM 2111 132 132 2111 0
METEOROLOGICAL FACILITY:
BROWNS FERRY NUCLEAR PLANT STABILITY BASED ON DELTA-T BETWEEN 10.03 AND 89.59 METERS WIND SPEED AND DIRECTION MEASURED AT 90.29 METER LEVEL MEAN WIND SPEED =
7.85 NOTE:
TOTALS AND SUBTOTALS ARE OBTAINED FROM UNROUNDED NUMBERS DATE PRINTED: 2013/02/06 E-172
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT ATTACHMENT 1 Deviations from ODCM Controls and Surveillance Requirements This report is to comply with Browns Ferry Nuclear Plant Offsite Dose Calculation Manual (ODCM). The ODCM requires that all deviations be reported in the Annual Radioactive Effluent Release Report.
During the reporting period, January 1, 2012 through December 31, 2012, there was one missed compensatory sample. On January 3, 2012, a potential non-representative gaseous sample was taken from the Reactor Building Effluent Monitor (2-RM-90-250) during the performance of 0-SI-4.8.B.1.A.2 (Airborne Effluent Release Rate by Manual Sampling When a Gaseous Effluent Monitor is Inoperable). This surveillance requires sampling once every 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> and a flow determination once every 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br />. When the initial sample was obtained, the compensatory sampler showed sufficient flow. After sampling, Chemistry personnel were informed that the valves upstream of the compensatory sampler were closed under a clearance (WO #112244367) to replace the moisture trap. The closed valves were the Reactor Building Exhaust (2-RTV-090-0308A), Turbine Building Exhaust (2-RTV-090-306A), and Refuel Zone Exhaust (2-RTV-090-307A). Since the compensatory sampler had sufficient flow, this indicated the closed valves had potential leak through. (PER 484911)
E-173
2012 BROWNS FERRY NUCLEAR PLANT UNITS 1, 2, AND 3 EFFLUENT AND WASTE DISPOSAL ANNUAL REPORT ATTACHMENT 2 2012 Inoperable Radiological Effluent Instrumentation Report This report is to comply with Browns Ferry Nuclear Plant Offsite Dose Calculation Manual (ODCM) Sections 1/2.1.1 and 1/2.1.2. The ODCM requires the exertion of best efforts to return inoperable instruments to operable status within 30 days. Failure to return such instruments to an operable status within the prescribed interval requires a description in the Annual Radioactive Effluent Release Report.
During the reporting period, January 1, 2012, through December 31, 2012, there were no radioactive gaseous effluent monitoring instruments and no liquid effluent monitoring instruments out of service for greater than 30 days.
E-174