L-2022-070, 2021 Annual Radiological Environmental Operating Report

From kanterella
(Redirected from ML22125A170)
Jump to navigation Jump to search

2021 Annual Radiological Environmental Operating Report
ML22125A170
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 05/03/2022
From: Lesniak T
Florida Power & Light Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
L-2022-070
Download: ML22125A170 (56)


Text

l=PL..

U. S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555-0001 Re:

Turkey Point Units 3 and 4 Docket Nos. 50-250 and 50-251 2021 Annual Radiological Environmental Operating Report May 3, 2022 L-2022-070 10 CFR 50.36b Enclosed is the 2021 Annual Radiological Environmental Operating Report for Turkey Point Units 3 and 4, as required by Technical Specification 6.9.1.3.

Should there be any questions or comments regarding this information, please contact Mr. William Nurnberger, Turkey Point Nuclear Chemistry Manager, at 305-246-6853.

Sincerely, 4~~

T~esflTak General Manager, R~gul91 Affairs Florida Power & Ligl4t-Company SM Enclosure cc:

Regional Administrator, Region II, USNRC Senior Resident Inspector, USNRC, Turkey Point Plant Florida Power & Light Company 9760 S.W. 344tn Street Homestead, FL 33035

Plant: Turkey Point Nuclear Units 3 & 4 Page 1 of 55 YEAR: 2021 Docket NOS Number: 50-250, 50-251 Annual Radiological Environmental Operating Report

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 2 of 55 Annual Radiological Environmental Operating Report TABLE OF CONTENTS 1.0 EXECUTIVE

SUMMARY

............................................................................................................. 5 1.1 Radiological Environmental Monitoring Program................................................................... 5 1.2 Reporting Levels................................................................................................................... 5 1.3 Sample Deviations................................................................................................................ 6 1.4 Program Modifications........................................................................................................... 6

2.0 INTRODUCTION

........................................................................................................................ 7 2.1 Radiological Environmental Monitoring Program................................................................... 7 A. Purpose............................................................................................................................ 7 2.2 Pathways Monitored.............................................................................................................. 8 2.3 Land Use Census.................................................................................................................. 8 3.0 RADIOLOGICAL ENVIRONMENTAL SAMPLING PROGRAM REQUIREMENTS...................... 9 4.0 INTERPRETATION AND TRENDS OF RESULTS.................................................................... 16 4.1 Air Particulate and Radioiodine Sample Results.................................................................. 16 4.2 Thermoluminescent Dosimetry (TLD) Sample Results........................................................ 17 4.3 Waterborne Sample Results................................................................................................ 17 4.3.1 Surface Water Results............................................................................................................... 17 4.3.2 Shoreline Sediment Sample Results......................................................................................... 18 4.4 Ingestion Sample Results.................................................................................................... 18 4.4.1 Crustacea and Fish Sample Results........................................................................................... 18 4.4.2 Broad Leaf Vegetation Sample Results...................................................................................... 18 4.5 Land Use Census Results................................................................................................... 18 4.6 Interlaboratory Comparison Results.................................................................................... 26 5.0 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

.......................... 26

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 3 of 55 Annual Radiological Environmental Operating Report ATTACHMENTS - Sample Deviations........................................................................................................ 30 - Monitoring Results Tables............................................................................................ 32 - Interlaboratory Comparison Program Results............................................................... 49 1.0 Summary....................................................................................................................................... 49 - Industry Initiative Ground Water Protection Program, 2021.......................................... 52 1.0 Description of Program.................................................................................................................. 52 2.0 Discussion..................................................................................................................................... 52 3.0 Results................................................................................................................................... 52 TABLES Table 1: Exposure Pathway - Airborne........................................................................................ 9 Table 2: Exposure Pathway - Direct Radiation.......................................................................... 10 Table 3: Exposure Pathway - Waterborne................................................................................. 12 Table 4: Exposure Pathway - Ingestion..................................................................................... 13 Table 5: Land Use Census - 2021 Nearest Residence, Garden and Milk Animal Within 5 Miles............................................................................................................................ 19 Table 6: Radiological Environmental Monitoring Program Summary......................................... 27 Table 7: Sample Deviations Table............................................................................................. 30 Table 8: Air Particulate - Gross Beta......................................................................................... 33 Table 9: Air Particulate Composite - Gamma............................................................................ 34 Table 10: Air Cartridges - Iodine-131........................................................................................ 35 Table 11: Direct Radiation - Indicators...................................................................................... 36 Table 12: Direct Radiation-Control........................................................................................... 36 Table 13: Surface Water - Tritium and Gamma......................................................................... 37 Table 14: Shoreline Sediment - Gamma................................................................................... 38 Table 15: Crustacea - Gamma.................................................................................................. 39 Table 16: Fish - Gamma............................................................................................................ 40 Table 17: Broad Leaf Vegetation - Gamma............................................................................... 41

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 4 of 55 Annual Radiological Environmental Operating Report TABLES (CONT'D)

Table 18: Supplemental Direct Radiation - Indicators................................................................ 42 Table 19: Supplemental Air Particulate - Gross Beta................................................................. 43 Table 20: Supplemental Air Particulate Composite - Gamma.................................................... 44 Table 21: Supplemental Air Cartridges - Iodine-131.................................................................. 45 Table 22: Supplemental Surface Water - Tritium and Gamma.................................................. 46 Table 23: Supplemental Shoreline Sediment - Gamma............................................................. 47 Table 24: Supplemental Broad Leaf Vegetation - Gamma......................................................... 48 Table 25: DOE's Mixed Analyte Performance Evaluation Program (MAPEP) 44 results....................................................................................................................................... 50 Table 26: DOE's Mixed Analyte Performance Evaluation Program (MAPEP) 45 results....................................................................................................................................... 51 Table 27: Ground Water - Tritium.............................................................................................. 53 FIGURES Figure 1: Sample Collection Sites - Near Station....................................................................... 14 Figure 2: Sample Collection Sites - Distant from Station........................................................... 15 Figure 3: Turkey Point 2021 REMP Gross Beta in Air, pCi/m3................................................... 16 Figure 4: 2021 PTN Direct Exposure TLDs: Quarterly Collection.............................................. 17

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 5 of 55 Annual Radiological Environmental Operating Report 1.0 EXECUTIVE

SUMMARY

1.1 Radiological Environmental Monitoring Program The data obtained through the Turkey Point Radiological Environmental Monitoring Program (REMP) verifies that the levels of radiation and concentrations of radioactive materials in environmental samples are not increasing. These measurements verify that the dose or dose commitment to members of the public, due to operation of Turkey Point Units 3 & 4, during the surveillance year, is well within the limits established by 10 CFR 50, Appendix I. The sampling period was from January 1, 2021 to December 31, 2021. Additionally, supplemental samples collected by the State of Florida, DOH, do not indicate adverse trends in the radiological environment.

All required lower limit of detection (LLD) capabilities were achieved in all sample analyses during 2021, as required by the Turkey Point Units 3 & 4 Technical Specifications. No measurable levels of radiation above baseline levels attributable to Turkey Point Nuclear operation were detected in the vicinity of PTN. The 2021 Radiological Environmental Monitoring Program thus substantiated the adequacy of source control and effluent monitoring at Turkey Point Nuclear with no observed impact of plant operations on the environment.

Turkey Point Nuclear established the REMP prior to the stations becoming operational to provide data on background radiation and radioactivity normally present in the area. PTN has continued to monitor the environment by sampling air, water, sediment, crustacea, fish and broadleaf vegetation, as well as measuring direct radiation. PTN also samples milk if milk-producing animals used for human consumption are present within five miles (8 km) of the plant.

The REMP includes sampling indicator and control locations within an approximate 20-mile radius of the plant. The REMP utilizes indicator locations near the site to show any increases or buildup of radioactivity that might occur due to station operation and control locations farther away from the site to indicate the presence of only naturally occurring radioactivity. PTN personnel compare indicator results with control results to assess any impact PTN operation might have had on the surrounding environment.

In 2021, environmental samples were collected for radiological analysis. The results of indicator locations were compared with control locations. It was concluded that no significant relationship exists between PTN operation and effect on the area around the plant. The review of 2021 data showed radioactivity levels in the environment were undetectable in many locations and near background levels in significant pathways.

Radiological environmental monitoring for the Turkey Point Plant is conducted by the State of Florida, Department of Health (DOH). Samples are collected and analyzed by DOH personnel. Samples are analyzed at the DOH Environmental Radiation Control Laboratory in Orlando, Florida. The 2021 Radiological Surveillance Quarterly Report data is provided by the State of Florida Bureau of Radiation Control and is presented in Attachment 2. The State of Florida is not involved in the (Industry Initiative) ground water monitoring program.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 6 of 55 Annual Radiological Environmental Operating Report 1.2 Reporting Levels No samples equaled or exceeded reporting levels.

1.3 Sample Deviations During 2021, environmental sampling was performed for seven media types addressed in the ODCM and for direct radiation. A total of 802 samples of the 802 scheduled were obtained. Of the scheduled samples, 100 percent were collected and analyzed in accordance with the requirements specified in the ODCM. contains the listing of sample deviations and actions taken.

1.4 Program Modifications There were no program modifications during the reporting period.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 7 of 55 Annual Radiological Environmental Operating Report

2.0 INTRODUCTION

This report is submitted pursuant to Specification 6.9 of Turkey Point Units 3 & 4 Technical Specifications. The Annual Radiological Environmental Operating Report provides information, summaries and analytical results pertaining to the Radiological Environmental Monitoring Program for the calendar year indicated. This report covers surveillance activities described in the Offsite Dose Calculation Manual (ODCM) meeting the requirements of Unit 3 and Unit 4 Technical Specifications.

2.1 Radiological Environmental Monitoring Program The Radiological Environmental Monitoring Program for the Turkey Point Plant is conducted pursuant to Control 5.1 of Turkey Point Unit 3 & 4 ODCM.

A. Purpose The purpose of the Radiological Environmental Monitoring Program is to provide representative measurements of radiation and of radioactive materials in those exposure pathways and for those radionuclides which lead to the highest potential radiation exposures of members of the public resulting from station operation.

The Radiological Environmental Monitoring Program also supplements the radiological effluent monitoring program by verifying that the measurable concentrations of radioactive materials and levels of radiation are not higher than expected on the basis of the effluent measurements and the modeling of the environmental exposure pathways.

Sample Locations, Types and Frequencies:

Direct radiation gamma exposure rate is monitored continuously at 23 locations by thermoluminescent dosimeters (TLDs). TLDs are collected and analyzed quarterly.

Airborne radioiodine and particulate samplers are operated continuously at six locations. Samples are collected and analyzed weekly. Analyses include Iodine-131, gross beta, and gamma isotopic measurements.

Surface water samples are collected from three locations. Samples are collected and analyzed monthly. Analyses include gamma isotopic and tritium measurements.

Shoreline sediment samples are collected from three locations coinciding with the locations for surface water samples. Samples are collected and analyzed semi-annually. Sediment samples are analyzed by gamma isotopic measurements.

Fish and invertebrate samples are collected from two locations coinciding with two of the locations for surface water samples. Samples are collected and analyzed semi-annually. Fish and invertebrate samples are analyzed by gamma isotopic measurements.

Broad leaf vegetation samples are collected from three locations. Samples are collected and analyzed monthly. Broad leaf vegetation samples are analyzed by gamma isotopic measurements.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 8 of 55 Annual Radiological Environmental Operating Report Table 1 through 4 provides specific information pertaining to sample locations, types, and frequencies.

Note: Ground Water Protection, NEI Initiative: The program and results are described in Attachment 4.

2.2 Pathways Monitored The airborne, direct radiation, waterborne and ingestion pathways are monitored as required by Control 5.1 of Turkey Point Unit 3 & 4 ODCM. A description of the REMP utilized to monitor the exposure pathways is described in the attached Tables and Figures.

Section 4.0 of this report provides a discussion of 2021 sampling results with Section 5.0 providing a summary of results for the monitored exposure pathways.

2.3 Land Use Census PTN conducts a land use census annually, as required by Turkey Point Units 3 & 4 ODCM. The purpose of this census is to identify changes in uses of land within five miles of PTN that would require modifications to the REMP and the Offsite Dose Calculation Manual (ODCM). Section 4.5 on the report contains a narrative on the results of the 2021 land use census.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 9 of 55 Annual Radiological Environmental Operating Report 3.0 RADIOLOGICAL ENVIRONMENTAL SAMPLING PROGRAM REQUIREMENTS Table 1: Exposure Pathway - Airborne Requirement Sample Point Description Distance and Direction Sampling and Collection Frequency Type and Frequency Of Analyses RADIOIODINE AND PARTICULATES 5 sample indicator locations and 1 sample control location.

T51 (2 mi. NNW) - Entrance Area to Biscayne National Park.

T57 (4 mi. NW) - Siren Pole 27, intersection of SW 112th Ave and SW 304th St.

T58 (1 mi. NW) - Turkey Point Entrance Road.

T72 (<1 mi. WSW) - Just before entrance to Land Utilizations access gate.

T41 (1.6 mi. WNW) - Palm Dr.

West of FPL Satellite School near the site boundary.

T64* (22 mi. NNE) - Natoma Substation, 2475 SW 16 Ct.

Continuous sampler operation with sample collection weekly or more frequently if required by dust loading.

Radioiodine Canisters - I-131 analysis weekly.

Air Particulate - Gross beta radioactivity analysis following filter change.

Air Particulate - Gamma Isotopic analysis quarterly.

  • Denotes Control sample

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 10 of 55 Annual Radiological Environmental Operating Report Table 2: Exposure Pathway - Direct Radiation Requirement Sample Point Description Distance and Direction Sampling and Collection Frequency Type and Frequency Of Analyses TLDS 22 indicator sample locations and 1 control sample location.

N-2 (2 mi N) - Convoy Point N-7 (7.1 mi N) - Black Point Marina parking lot on siren pole N-10 (10.6 mi N) - Old Cutler Rd across from Perdue Med. Ctr. On siren pole.

NNW-2 (2.2 mi NNW) - East End of N. Canal Dr. on siren pole E. of 117th Ave.

NNW-10 (9.2 mi NNW) - Bailes Rd.

E. of US 1 on siren pole.

NW-1 (1.4 mi NW) - Turkey Point Entrance Rd.

NW-5 (3.9 mi NW) - Intersection of Mowry Dr. and 117th Ave. on siren pole.

NW-10 (10 mi NW) - On Newtown Rd. N. of Coconut Palm Drive on siren pole.

W-5 (5.3 mi W) - Palm Drive 0.3 mi west of Tallahassee Rd.

WNW-10 (9.8 mi WNW) - NW 2nd Ave. S. of Campbell Dr. at Hmstd.

Middle School on siren pole.

W-1 (0.7 mi W) - On site north side of Discharge Canal.

Quarterly mR exposure quarterly.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 11 of 55 Annual Radiological Environmental Operating Report Table 2: Exposure Pathway - Direct Radiation Requirement Sample Point Description Distance and Direction Sampling and Collection Frequency Type and Frequency Of Analyses TLDS (Contd) 22 indicator sample locations and 1 control sample location.

W-9 (8.6 mi W) - Card Sound Rd. 0.6 mi SSE of US 1 on siren pole.

WSW-8 (7.8 mi WSW) - Card Sound Rd. 3.4 mi. SSE of US 1 on siren Pole.

SW-1 (1 mi SW) - On site near land utilization offices.

SSE-1 (1 mi SSE) - On site South East side of cooling canals at Turtle Point.

SW-8 (8 mi SW) - Card Sound Rd. 5 mi. SSE of US 1 at entrance to Navy facility.

SSW-5 (5 mi SSW) - On site, southwest corner of cooling canals.

SSW-10 (10 mi SSW) - At Card Sound Bridge on siren pole.

S-5 (5 mi S) - On site, south east end of cooling canals.

S-10 (10 mi S) - Card Sound Road at Steamboat Creek.

SSE-10 (9 mi SSE) - Ocean Reef.

NNE-22* (22.6 mi NNE) - Natoma Substation.

WNW2 (1.6 mi WNW) - Palm Dr.

West of FPL Satellite School, near Site Boundary.

Quarterly mR exposure quarterly.

  • Denotes Control sample

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 12 of 55 Annual Radiological Environmental Operating Report Table 3: Exposure Pathway - Waterborne Requirement Sample Point Description Distance and Direction Sampling and Collection Frequency Type and Frequency Of Analyses SURFACE WATER 2 indicator sample locations and 1 control sample location.

T42 (<1 mi. ENE) - Biscayne Bay at Turkey Point.

T81 (6 mi. S) - Card Sound, near Mouth of Old Discharge Canal.

T67* (13-18 mi. N, NNE) - Near Biscayne Bay, Vicinity of Cutler Plant, North to Matheson Hammock Park Grab samples Monthly Gamma isotopic analysis and tritium analysis monthly.

SEDIMENT FROM SHORELINE 2 indicator sample locations and 1 control sample location. Locations coincide with the surface water sample locations.

T42 (<1 mi ENE) - Biscayne Bay at Turkey Point.

T81 (6 mi. S) - Card Sound, near Mouth of Old Discharge Canal.

T67* (13-18 mi. N, NNE) - Near Biscayne Bay, Vicinity of Cutler Plant, North to Matheson Hammock Park Semi-annually Gamma isotopic analysis semi-annually.

  • Denotes Control sample

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 13 of 55 Annual Radiological Environmental Operating Report

  • Denotes Control sample
  • Denotes Control sample Table 4: Exposure Pathway - Ingestion Requirement Sample Point Description Distance and Direction Sampling and Collection Frequency Type and Frequency Of Analyses CRUSTACEA AND FISH 1 indicator sample location and 1 control sample location.

T81 (6 mi. S) - Card Sound, near Mouth of Old Discharge Canal.

T67* (13-18 mi. N, NNE) - Near Biscayne Bay, Vicinity of Cutler Plant, North to Matheson Hammock Park Semi-annually Gamma isotopic analysis semi-annually.

BROADLEAF VEGATATION 2 indicator sample locations and 1 control sample location.

T40 (3 mi W) - South of Palm Dr. on S.W. 117th Street Extension.

T41 (2 mi WNW) - Palm Dr. West of FPL Satellite School near the site boundary.

T67* (13-18 mi. N, NNE) - Near Biscayne Bay, Vicinity of Cutler Plant, North to Matheson Hammock Park Monthly Gamma isotopic analysis monthly.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 14 of 55 Annual Radiological Environmental Operating Report Figure 1: Sample Collection Sites - Near Station

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 15 of 55 Annual Radiological Environmental Operating Report Figure 2: Sample Collection Sites - Distant from Station

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 16 of 55 Annual Radiological Environmental Operating Report 4.0 INTERPRETATION AND TRENDS OF RESULTS 4.1 Air Particulate and Radioiodine Sample Results In 2021 there were no samples above the LLD for I-131. Indicator gross beta air particulate results for 2021 were comparable to results obtained from 2018-2020 of the operational REMP. Results are reported in picocuries per cubic meter (pCi/m3).

Monitoring Period Result 2018 - 2020 (Minimum Value) 0.002 2021 Average Value 0.014 2018 - 2020 (Maximum Value) 0.032 Gross beta activity is attributed to naturally occurring radionuclides. Table 6, which include gross beta concentrations and provide a comparison of the indicator and control means and ranges emphasizes the consistent trends seen in this pathway to support the presence of naturally occurring activity. Figure 3 is a comparison of the weekly Gross Beta results for 2021.Therefore, it can be concluded that the airborne pathway continues to be unaffected by Turkey Point Nuclear operations.

0.00 0.01 0.02 0.03 0.04 0.05 0.06 0.07 0.08 1

3 5

7 9

11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 Conc. pCi/m3 week of year Figure 3: Turkey Point 2021 REMP Gross Beta in Air, pCi/m3 Minimum Average Maximum

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 17 of 55 Annual Radiological Environmental Operating Report 4.2 Thermoluminescent Dosimetry (TLD) Sample Results Turkey Point Nuclear reports relies on comparison of the indicator locations to the control as a measure of plant impact. Turkey Point Nuclears comparison of the indicator to the control, as seen in Table 6, identified no noticeable trend that would indicate that the ambient radiation levels are being affected by plant operations. In addition, the quarterly indicator averages shown in the TLD radiation dose comparison graph below shows the 2021 indicator results are comparable to control location results. Overall, Turkey Point Nuclear concluded that the ambient radiation levels are not being affected by plant operations.

4.3 Waterborne Sample Results Analytical results for 2021 surface water samples were similar to those reported in previous years. Gamma radionuclides and tritium analytical results for 2021 waterborne samples were below the ODCM-required LLD similar to those reported in previous years. These results are further explained below.

4.3.1 Surface Water Results Samples were collected from two indicator and one control location and analyzed for gamma radionuclides and tritium. Tritium was detected in 4 out of 24 indicator location samples with an average concentration of 97 pCi/L which is consistent with results seen in previous operational years. There were no plant related gamma radionuclides detected in any of the control or indicator location samples. Therefore, the operation of Turkey Point Nuclear had no definable impact on this waterborne pathway during 2021.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 18 of 55 Annual Radiological Environmental Operating Report 4.3.2 Shoreline Sediment Sample Results Sediment samples were collected from two indicators and one control location in 2021 and analyzed for gamma radionuclides. Plant related gamma radionuclides were below the LLD limits at both indicator and control locations. Turkey Point Nuclear operations had no significant impact on the environment or public by this waterborne pathway.

4.4 Ingestion Sample Results 4.4.1 Crustacea and Fish Sample Results Crustacea and Fish samples were collected from one indicator and one control location and analyzed for gamma radionuclides. In 2021, gamma radionuclides were below detectable limits which are consistent with the results seen in previously operational years. Therefore, based on these measurements, Turkey Point Nuclear operations had no significant radiological impact upon the environment or public by this ingestion pathway.

4.4.2 Broad Leaf Vegetation Sample Results The REMP has detected radionuclides prior to 1990 in vegetation that are attributable to other sources. These include the radioactive plume release due to reactor core degradation at Chernobyl Nuclear Power Plant in 1986 and atmospheric weapons testing.

In 2021, Broad Leaf Vegetation samples were collected from two indicator and one control locations and analyzed for gamma radionuclides. The 2021 Cs-137 was detected in samples collected from the indicator and control locations. This activity identified could be from weapons fallout testing 30-40 years ago and reactor accidents at Chernobyl and are contributors. Therefore, based on these measurements, Turkey Point Nuclear operations had no significant radiological impact upon the environment or public by this ingestion pathway.

4.5 Land Use Census Results The latest land use census (performed in 2021) did not identify any new locations that yielded a calculated dose or dose commitment greater than those currently calculated (see Table 5).

The land use census identified no changes in the new resident census.

There were no changes in the milk cows/goats or garden census in 2021.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 19 of 55 Annual Radiological Environmental Operating Report Table 5: Land Use Census -2021 Nearest Residence, Garden, and Milk Animal Within Five Miles SECTOR NEAREST RESIDENCE/BUSINESS NEAREST GARDEN (A)

NEAREST MILK ANIMAL N

1.9 mi @ 349° 1.98 mi @ 349° 2.0 mi @ 354° NNE NE ENE E

ESE SE SSE S

SSW SW WSW W

WNW 1.7 mi @ 302° 3.7 mi @ 302° 4.5 mi @ 303° 6.0 mi @ 295° NW 3.6 mi @ 304° 3.7 mi @ 311° 3.8 mi @ 316° 3.9 mi @ 314° NNW 4.4 mi @ 333° 4.7 mi @ 328° 4.4 mi @ 332° 4.7 mi @ 328° (A) - Only gardens with an estimated total area of 500 square feet, or more, and producing green leafy vegetables are considered.

  • - No suitable sites were located within a five-mile range.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 20 of 55 Annual Radiological Environmental Operating Report TURKEY POINT RESIDENCE SURVEY RESULTS July 2021 Sector Range Bearing Nearest Residence/Business Location N (A) 1.9 miles 349° This is the Homestead Bayfront Park complex. Contact is Jim Wyath. Office hours are 8:30 to 4:30, 7 days a week. Some occasional overnight recreational occupancy (up to 4 nights) on boats at the marina. Approximately 10 workers, 7 days a week, hours and number of varies. Summer weekends can see 1000+

visitors. There is always someone here 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> with more workers in the summer than the rest of the year (February thru September have the highest peak of workers). LaPlaya restaurant is open at the park weekdays with 8 to 10 employees from 11 am to 8:30pm. Weekends open till 10 pm and may have up to 15 employees. N25° 27.683 W80° 20.200.

N (B) 1.98 miles 349° South Glade Outfitters. Located on opposite side of building from office of Homestead Bayfront Park. Manager is Robert and have 2-3 employees. Hours are weekdays 7 am to 5 pm, Fridays till 6 pm Weekends 7 am - 6 pm. Hours may vary depending on the weather. N25° 27.767 W80° 20.206.

N (C) 2.0 miles 354° Biscayne National Park at Convoy Point. Open 7 am to 5:30 pm everyday. There are 65 employees including volunteers and individuals at the institute. The one ranger and two seasonal employees are there all year. There are about 500,000 visitors (more including boaters) per year. Contacts include: Michelle Penick, Chief of Facilities, J. Ernest Jutte, Chief of Administration, 305-242-7721 (office) 202-438-6636 (mobile), and Cindy Holl (administrator) 239-695-1114. N25° 27.817' W80° 20.067'.

NNE No residences were located within a five-mile range.

NE No residences were located within a five-mile range.

ENE No residences were located within a five-mile range.

E No residences were located within a five-mile range.

ESE No residences were located within a five-mile range.

SE No residences were located within a five-mile range.

SSE No residences were located within a five-mile range.

S No residences were located within a five-mile range.

SSW No residences were located within a five-mile range.

SW No residences were located within a five-mile range.

WSW No residences were located within a five-mile range.

W No residences were located within a five-mile range.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 21 of 55 Annual Radiological Environmental Operating Report TURKEY POINT RESIDENCE SURVEY RESULTS July 2021 (cont.)

Sector Range Bearing Nearest Residence/Business Location WNW (A) 1.7 miles 302° FP&L daycare center and shooting range near the entrance to the Turkey Point Plant. Contact is Yudisvel "Judy" Diaz, Director.

There are 15 employees with 90 children currently enrolled, ages 6 months to 5 yrs. Occasionally, they will have school aged children. The center is open from 6am to 6pm Monday thru Friday. The number of people and times at the shooting range varies. N25° 26.817' W80° 21.217'.

WNW (B) 3.7 miles 302° Two elderly people live at 11790 Canal Drive on the south side of Canal Drive (SW 328 St) west of SW 117th Ave (no gardens).

Their son lives onsite on weekends, 2-3 nights/week. Residents plan on selling soon. Next door, to the east, is a makeshift produce stand which sells coconuts, limes, mandarin oranges, flowers, garlic, mangoes, papaya, avocado, honey, melons, sugar cane, ginger, plantains and pumpkins. It is not associated with the house next door. Two employees may be working there from 8 am to 6 pm. N25° 27.767' W80° 22.867'.

NW (A) 3.6 miles 304° The Waste Management Homestead Landfill is located north of Canal Drive (SW 328th St) and east of SW 117th Ave. There are 9 full time employees onsite Monday thru Friday from 7 am to 3:30 pm. N25° 27.833' W80° 22.767'.

NW (B) 3.7 miles 311° 11000 SW 320th St. Per property records, this house is on land zoned agriculture and the owners live in Texas. Unable to verify if anyone lives there because the gate is locked and the residence is too far from the road to see anything. Noticed the property was for sale a few months ago and there is a backhoe doing construction. N25° 28.217' W80° 22.567'.

NW (C) 3.8 miles 316° High Hope Nursery at 11400 SW 316th St. Contact is George Sprinkle, Owner and General Manager. This nursery has approximately 35 employees. Hours of operations are 7am to 5pm Monday thru Friday, with some work on Saturdays until noon. A man lives onsite providing security. N25° 28.441' W80° 22.430'.

NW (D) 3.9 miles 314° Snapper Creek Nursery at 11600 SW 316th Street. 14 workers that work Monday thru Friday 7 am to 5 pm. Contact is Elmer.

Security is provided by another person who lives onsite. N25° 28.444' W80° 22.560'.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 22 of 55 Annual Radiological Environmental Operating Report TURKEY POINT RESIDENCE SURVEY RESULTS July 2021 (cont.)

Sector Range Bearing Nearest Residence/Business Location NNW (A) 4.4 miles 333° 29800 SW 107th Ave. Per property records, this is a small one bedroom residence on land zoned as mixed use agricultural. Spoke to the woman who lives there with three men and two children.

N25° 29.450' W80°21.817'.

NNW (B) 4.7 miles 328° Previously SFM Tree Farm. Now Mirtica and Sons Dragon Fruit Farm. Entrance at the end of SW 296th St. Contact is Ernesto Gonzalez Abreu. Owner lives off property in Miami. Multiple attempts made to speak to someone on property.

N25° 29.564' W80° 22.264'.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 23 of 55 Annual Radiological Environmental Operating Report TURKEY POINT GARDEN SURVEY RESULTS July 2021 Sector Range Bearing Nearest Garden Location (with estimated total area of 500 square feet, or more, and producing green leafy vegetables).

N No suitable gardens were located within a five-mile range.

NNE No suitable gardens were located within a five-mile range.

NE No suitable gardens were located within a five-mile range.

ENE No suitable gardens were located within a five-mile range.

E No suitable gardens were located within a five-mile range.

ESE No suitable gardens were located within a five-mile range.

SE No suitable gardens were located within a five-mile range.

SSE No suitable gardens were located within a five-mile range.

S No suitable gardens were located within a five-mile range.

SSW No suitable gardens were located within a five-mile range.

SW No suitable gardens were located within a five-mile range.

WSW No suitable gardens were located within a five-mile range.

W No suitable gardens were located within a five-mile range.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 24 of 55 Annual Radiological Environmental Operating Report TURKEY POINT GARDEN SURVEY RESULTS July 2021 (cont.)

Sector Range Bearing Nearest Garden Location (with estimated total area of 500 square feet, or more, and producing green leafy vegetables).

WNW (A) 4.5 miles 303° Thai Farm. South of Mowry Drive (SW 320th St) and about 0.6 miles west of Allapattah Rd (SW 117th Ave). Growing guava, dragon fruit, papaya, palm, bamboo, and more. No one present.

Phone number on farm sign reached the previous owner who sold 3 years ago and does not know how to contact the new owners.

N25° 28.217' W80° 23.467'.

WNW (B) 6.0 miles 295° Farm Share, Inc at 14125 SW 320th St, where farmers donate locally grown produce to be given to charitable organizations.

Produce donations usually start in November and run through April. About 20 workers present from 8 am to 4:30 pm Monday thru Friday. The produce donated is usually tomatoes, bananas, squash, green beans, okra, corn, potatoes, watermelon and zucchini. The contact is Nick Sanchez or Aaron Garcia, Facility Manager, 305-246-3276 (office), 305-926-9832 (cell).

N25° 28.255' W80° 25.111'.

NW No suitable gardens were located within a five-mile range.

NNW (A) 4.4 miles 332° Under the Vine. 11100 SW 296th St. Entrance at SW 107th Ave &

SW 296th St just east of SFM Tree Farm/Mirtica Farm. Growing only dragon fruit. Open Mon-Sat 8:00-5:00. 3 employees plus the owner, Cindy, work here. Sometimes they hire extra help. The owner's brother, Pepper, sometimes spends the weekends onsite.

N25° 29.464' W80° 21.828'.

NNW (B) 4.7 miles 328° Previously SFM Tree Farm. Now Mirtica and Sons Dragon Fruit Farm. Entrance at the end of SW 296th St. Noticed bananas, dragon fruit, plantain tress, coconuts and mangoes growing in various areas on the farm. Also noticed beehives. Owner lives off property in Miami. Multiple attempts made to speak to someone on property. N25° 29.564' W80° 22.264'.

Note: At the time of our survey, many fields in the area surveyed were bare soil or cover crops. Other than the sites already described above, the only non-ornamental crops known to have been grown in the survey area were: bananas, beans, corn, guava, malanga, papaya, eggplant, sorghum, squash, sugar cane, tambis, okra and melon.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 25 of 55 Annual Radiological Environmental Operating Report TURKEY POINT MILK ANIMAL SURVEY RESULTS July 2021 Sector Nearest Milk Animals (cows or goats).

N No potential milk animals were located within five miles.

NNE No potential milk animals were located within five miles.

NE No potential milk animals were located within five miles.

ENE No potential milk animals were located within five miles.

E No potential milk animals were located within five miles.

ESE No potential milk animals were located within five miles.

SE No potential milk animals were located within five miles.

SSE No potential milk animals were located within five miles.

S No potential milk animals were located within five miles.

SSW No potential milk animals were located within five miles.

SW No potential milk animals were located within five miles.

WSW No potential milk animals were located within five miles.

W No potential milk animals were located within five miles.

WNW No potential milk animals were located within five miles.

NW No potential milk animals were located within five miles.

NNW No potential milk animals were located within five miles.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 26 of 55 Annual Radiological Environmental Operating Report 4.6 Interlaboratory Comparison Results contains result summary for Interlaboratory Comparison program for the Department of Energy Mixed Analyte Performance Evaluation Program (MAPEP).

These satisfied the requirement of Control 5.3 of the ODCM for the Interlaboratory Comparison Program.

5.0 RADIOLOGICAL ENVIRONMENTAL MONITORING PROGRAM

SUMMARY

1.

Table 6, Radiological Environmental Monitoring Program Summary, summarizes data for the 2021 REMP program.

Sample Type (Units)

Type / Number of Analyses(1)

LLD (2)

Indicator Locations Mean (F)(3)

[Range]

Indicator(4) Location

[Highest Annual Mean]

Mean (F)(3)

[Range]

Control Locations Mean (F)(3) [Range]

Number of Non Routine Results(5)

GB / 312 0.01 0.0141 (256 / 260)

T72 0.0149 (49 / 52) 0.0146 (52 / 52) 0

[0.0020 - 0.0270]

(<1 mi. WSW)

[0.0040 - 0.0270]

[0.003 - 0.0290]

GS / 24 Be-7 0.1164 (20 / 20)

T72 0.1218 (4 / 4) 0.1145 (4 / 4) 0

[0.0802 - 0.1680]

(<1 mi. WSW)

[0.0830 - 0.1610]

[0.0843 - 0.1620]

K-40

< LLD N/A N/A

< LLD 0

Cs-134 0.05

< LLD N/A N/A

< LLD 0

Cs-137 0.06

< LLD N/A N/A

< LLD 0

Pb-210 0.0104 (12 / 20)

T72 0.0137 (2 / 4) 0.0103 (3 / 4) 0

[0.0068 - 0.0137]

(<1 mi. WSW)

[0.0136 - 0.0137]

[0.0069 - 0.0134]

Airborne Iodine (pCi/m3)

I-131 / 312 0.07

< LLD N/A N/A

< LLD 0

Gamma / 88 (6) 3.8 (88 / 88)

NW-10 4.6 (4 / 4)

N/A 0

[2.7 - 5.1]

(10 mi NW)

[4.1 - 5.1]

Gamma / 4 N/A N/A N/A 4.1 (4 / 4) 0

[3.7 - 4.4]

LEGEND:

(1) - GB = Gross beta; I-131 = Iodine-131; H-3 = Tritium; GS = Gamma scan.

(2) - LLD = Required lower limit of detection based on Turkey Point ODCM.

(3) - Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parenthesis (F).

(4) - Locations are specified (1) by name and (2) direction relative to reactor site.

(5) - Non-routine results are those which exceed ten times the control station value. If no control station value is available, the result is considered non-routine if it exceeds ten times the preoperational value for the location.

(6) - LLD is not defined in Turkey Point ODCM.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 27 of 55 Direct Radiation Indicator TLD

(µR/hour)

Direct Radiation Control TLD

(µR/hour)

(6)

Table6: Radiological Environmental Monitoring Program Summary Annual Radiological Environmental Operating Report Air Particulate (pCi/m3)

Sample Type (Units)

Type / Number of Analyses(1)

LLD (2)

Indicator Locations Mean (F)(3)

[Range]

Indicator(4) Location

[Highest Annual Mean]

Mean (F)(3)

[Range]

Control Locations Mean (F)(3) [Range]

Number of Non Routine Results(5)

H-3 / 36 3,000 97 (4 / 24)

T81 99 (2 / 12) 118 (1 / 12) 0

[72 - 118]

(6 mi. S)

[92 - 105]

[<LLD - 118]

GS / 36 K-40 305 (24 / 24)

T81 327 (12 / 12) 242 (10 / 12) 0

[181 - 409]

(6 mi. S)

[211 - 409]

[102 - 348]

GS / 6 Be-7

< LLD N/A N/A

< LLD 0

K-40 135 (1 / 4)

T81 135 (1 / 2) 109 (2 / 2) 0

[<LLD - 135]

(6 mi. S)

[<LLD - 135]

[88 - 130]

Cs-137 180

< LLD N/A N/A

< LLD 0

Pb-210 416 (2 / 4)

T81 416 (2 / 2)

< LLD 0

[316 - 515]

(6 mi. S)

[316 - 515]

Ra-226 703 (3 / 4)

T42 593 (1 / 2) 181 (1 / 2) 0

[543 - 974]

(<1 mi ENE)

[<LLD - 593]

[<LLD - 181]

Th-232

<LLD N/A N/A

< LLD 0

U-235 44 (3 / 4)

T81 48 (2 / 2) 11 (1 / 2) 0

[34 - 61]

(6 mi. S)

[34 - 61]

[<LLD - 11]

U-238 261 (4 / 4)

T81 387 (2 / 2) 91 (2 / 2) 0

[118 - 495]

(6 mi. S)

[278 - 495]

[87 - 94]

LEGEND:

(1) - GB = Gross beta; I-131 = Iodine-131; H-3 = Tritium; GS = Gamma scan.

(2) - LLD = Required lower limit of detection based on Turkey Point ODCM.

(3) - Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parenthesis (F).

(4) - Locations are specified (1) by name and (2) direction relative to reactor site.

(5) - Non-routine results are those which exceed ten times the control station value. If no control station value is available, the result is considered non-routine if it exceeds ten times the preoperational value for the location.

(6) - LLD is not defined in Turkey Point ODCM.

Surface Water (pCi/L)

Sediment (pCi/kg dry)

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 28 of 55 Annual Radiological Environmental Operating Report Table6: Radiological Environmental Monitoring Program Summary

Sample Type (Units)

Type / Number of Analyses(1)

LLD (2)

Indicator Locations Mean (F)(3)

[Range]

Indicator(4) Location

[Highest Annual Mean]

Mean (F)(3)

[Range]

Control Locations Mean (F)(3) [Range]

Number of Non Routine Results(5)

GS / 4 K-40 1380 (2 / 2)

T81 1380 (2 / 2) 1440 (2 / 2) 0

[1360 - 1400]

(6 mi. S)

[1360 - 1400]

[1380 - 1500]

Ra-226 495 (1 / 2)

T81 495 (1 / 2)

<LLD 0

[<LLD - 495]

(6 mi. S)

[<LLD - 495]

Ra-228

<LLD N/A N/A

<LLD 0

GS / 4 K-40 2560 (2 / 2)

T81 2560 (2 / 2) 2725 (2 / 2) 0

[1990 - 3130]

(6 mi. S)

[1990 - 3130]

[2160 - 3290]

Ra-226

< LLD N/A N/A

< LLD 0

Ra-228

< LLD N/A N/A

< LLD 0

GS / 36 Be-7 1444 (24 / 24)

T40 1498 (12 / 12) 1440 (12 / 12) 0

[582 - 2440]

(3 mi W)

[651 - 2440]

[728 - 2510]

K-40 3969 (24 / 24)

T41 4597 (12 / 12) 3661 (12 / 12) 0

[2580 - 5510]

(2 mi WNW)

[2580 - 5510]

[2400 - 4950]

Cs-137 80 33 (15 / 24)

T40 38 (11 / 12) 10 (8 / 12) 0

[4 - 57]

(3 mi W)

[18 - 54]

[5 - 14]

Pb-210 223 (8 / 12)

T41 261 (5 / 12) 178 (5 / 12) 0

[62 - 521]

(2 mi WNW)

[87 - 521]

[44 - 404]

Pb-212

< LLD N/A N/A 11 (2 / 12) 0

[5 - 16]

Ra-226

< LLD N/A N/A

< LLD 0

LEGEND:

(1) - GB = Gross beta; I-131 = Iodine-131; H-3 = Tritium; GS = Gamma scan.

(2) - LLD = Required lower limit of detection based on Turkey Point ODCM.

(3) - Mean and range based upon detectable measurements only. Fraction of detectable measurements at specified locations is indicated in parenthesis (F).

(4) - Locations are specified (1) by name and (2) direction relative to reactor site.

(5) - Non-routine results are those which exceed ten times the control station value. If no control station value is available, the result is considered non-routine if it exceeds ten times the preoperational value for the location.

(6) - LLD is not defined in Turkey Point ODCM.

Annual Radiological Environmental Operating Report Crustacea (pCi/kg wet)

Broad Leaf (pCi/kg wet)

Fish (pCi/kg wet)

Table6: Radiological Environmental Monitoring Program Summary Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 29 of 55

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 30 of 55 Annual Radiological Environmental Operating Report Page 1 of 2 Sample Deviations Table 7: Sample Deviations Table Comment No.

Sample Media Affected Sample Location Date Problem Evaluation / Actions 1

Air Sample T72 01/06/21 Pump Failure Vacuum Pump failed, estimated run time was 64 out of 191 hours0.00221 days <br />0.0531 hours <br />3.158069e-4 weeks <br />7.26755e-5 months <br />. T72 vacuum pump was replaced. AR# 02399193 2

Air Sample T72 01/20/21 Power Outage Power outage at station T72, estimated run time was 20 out of the 150 hours0.00174 days <br />0.0417 hours <br />2.480159e-4 weeks <br />5.7075e-5 months <br />. The power was restored 01/22/21 at 14:03. AR# 02399193 3

Air Sample T72 01/25/21 Power Outage Due to previous power outage, this weeks filter ran for 74 hours8.564815e-4 days <br />0.0206 hours <br />1.223545e-4 weeks <br />2.8157e-5 months <br />. AR# 02399193 4

Surface Water T97 05/11/21 Exceeded Reporting Level The results for T97 (Cooling Canal, Intake) identified a tritium value of 12,658 pCi/L. A condition report is being generated as the results is above the reporting level of 12,000 pCi/L. AR# 02414363 5

Air Sample T51 05/26/21 Pump Failure Vacuum Pump failed, estimated run time 91 hours0.00105 days <br />0.0253 hours <br />1.50463e-4 weeks <br />3.46255e-5 months <br /> out of 149 hours0.00172 days <br />0.0414 hours <br />2.463624e-4 weeks <br />5.66945e-5 months <br />. T51 Vacuum pump was replaced. AR# 02399193 6

Air Sample T51 06/02/21 Power Outage Power outage at station T51, estimated run time was 124 out of the 161 hours0.00186 days <br />0.0447 hours <br />2.662037e-4 weeks <br />6.12605e-5 months <br />.

AR# 02399193 7

Air Sample T72 06/09/21 Sample Missing Air Cartridge lost somewhere between shipping it and receiving it. AR# 02399193 8

Air Sample T58 08/18/21 Pump Failure Vacuum Pump failed, estimated run time was 74.3 out of 120.9 hours1.041667e-4 days <br />0.0025 hours <br />1.488095e-5 weeks <br />3.4245e-6 months <br />. T58 sample pump was replaced. AR# 02411663 9

Surface Water T84 10/11/21 Exceeded Reporting Level The results for T84 (Cooling Canal, Discharge) identified a tritium value of 13,471 pCi/L. A condition report is being generated as the results is above the reporting level of 12,000 pCi/L. AR# 02422816

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 31 of 55 Annual Radiological Environmental Operating Report Table 7: Sample Deviations Table Contd Comment No.

Sample Media Affected Sample Location Date Problem Evaluation / Actions 10 Surface Water T97 10/11/21 Exceeded Reporting Level The results for T97 (Cooling Canal, Intake) identified a tritium value of 13,492 pCi/L. A condition report is being generated as the results is above the reporting level of 12,000 pCi/L. AR# 02422816 11 Surface Water T08 11/03/21 Exceeded Reporting Level The results for T08 (Southern Shore of canal system, west of Grand Bridge) identified a tritium value of 12,214 pCi/L. A condition report is being generated as the results is above the reporting level of 12,000 pCi/L. AR#

02422816 12 Surface Water T97 11/03/21 Exceeded Reporting Level The results for T97 (Cooling Canal, Intake) identified a tritium value of 12,474 pCi/L. A condition report is being generated as the results is above the reporting level of 12,000 pCi/L. AR# 02422816 13 Milk T99 2021 Sample Unavailable Goat milk sample was unavailable this year. The farm has not had any milking goats. AR# 0422809 Page 2 of 2 Sample Deviations

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 32 of 55 Annual Radiological Environmental Operating Report ATTACHMENT 2 Monitoring Results Tables RADIOLOGICAL SURVEILLANCE OF FLORIDA POWER AND LIGHT COMPANY'S TURKEY POINT SITE 2021 First Quarter, 2021 Second Quarter, 2021 Third Quarter, 2021 Fourth Quarter, 2021

Year: 2021 Page 33 of 55 End Date T41 (Indicator) T51 (Indicator)

T57 (Indicator)

T58 (Indicator)

T64 (Control)

T72(1)

(Indicator)

LLD 0.01 0.01 0.01 0.01 0.01 0.01 01/06/2021 0.011 0.011 0.013 0.011 0.013 0.014 01/14/2021 0.021 0.021 0.017 0.016 0.017 0.020 01/20/2021 0.015 0.022 0.022 0.019 0.020

<0.048 01/25/2021 0.019 0.015 0.018 0.014 0.018 0.016 02/02/2021 0.015 0.017 0.016 0.014 0.017 0.011 02/09/2021 0.015 0.011 0.011 0.012 0.018 0.015 02/17/2021 0.004 0.003 0.002 0.003 0.007

<0.005 02/25/2021 0.007 0.011 0.011 0.009 0.006 0.008 03/02/2021 0.011 0.009 0.010 0.008 0.009 0.011 03/08/2021 0.010 0.011 0.011 0.012 0.013 0.010 03/16/2021 0.019 0.018 0.016 0.015 0.016 0.018 03/25/2021 0.012 0.014 0.014 0.011 0.014 0.013 03/31/2021 0.012 0.011 0.009 0.010 0.005 0.009 04/06/2021 0.021 0.020 0.022 0.016 0.021 0.024 04/14/2021 0.022 0.019 0.021 0.024 0.027 0.020 04/22/2021 0.015 0.025 0.023 0.026 0.029 0.027 04/29/2021 0.017 0.021 0.018 0.019 0.021 0.021 05/05/2021 0.017 0.014 0.016 0.015 0.020 0.016 05/12/2021 0.014 0.010 0.012 0.012 0.012 0.017 05/20/2021 0.011 0.011 0.009 0.011 0.012 0.008 05/26/2021 0.016 0.013 0.015 0.015 0.015 0.017 06/02/2021 0.017 0.016 0.021 0.019 0.020 0.018 06/09/2021 0.006 0.009 0.010 0.008 0.011 0.009 06/16/2021 0.012 0.014 0.012 0.009 0.009 0.011 06/24/2021 0.013 0.014 0.016 0.013 0.014 0.015 06/30/2021 0.010 0.007 0.010 0.010 0.009 0.010 07/08/2021 0.005 0.012 0.010 0.010 0.009 0.011 07/13/2021 0.020 0.023 0.023 0.017 0.023 0.017 07/21/2021 0.009 0.013 0.011 0.015 0.013 0.013 07/29/2021 0.018 0.015 0.012 0.014 0.012 0.016 08/04/2021 0.010 0.017 0.009 0.014 0.010 0.016 08/11/2021 0.008 0.006 0.009 0.007 0.006 0.010 08/18/2021 0.009 0.012 0.010 0.008 0.008 0.012 08/24/2021 0.020 0.023 0.021 0.023 0.022 0.024 08/31/2021 0.015 0.018 0.017 0.017 0.015 0.019 09/09/2021 0.021 0.017 0.016 0.020 0.021 0.017 09/14/2021 0.017 0.021 0.018 0.020 0.019 0.021 09/21/2021 0.009 0.007 0.005 0.009 0.003 0.004 09/30/2021 0.013 0.014 0.015 0.017 0.017 0.015 10/06/2021 0.017 0.021 0.016 0.023 0.018 0.018 10/12/2021 0.018 0.019 0.014 0.018 0.016 0.017 10/20/2021 0.019 0.016 0.023 0.018 0.018 0.019 10/25/2021 0.012 0.015 0.009 0.013 0.010 0.013 11/02/2021 0.015 0.013 0.015 0.011 0.012 0.016 11/10/2021 0.009 0.009 0.006 0.010 0.010 0.012 11/17/2021 0.014 0.012 0.014 0.013 0.014 0.015 11/24/2021 0.007 0.005 0.006 0.006 0.010 0.004 12/01/2021 0.011 0.015 0.018 0.022 0.025 0.021 12/08/2021 0.013 0.013 0.016 0.016 0.014 0.017 12/16/2021 0.010 0.013 0.012 0.011 0.013 0.012 12/21/2021 0.005 0.004 0.006

<0.007 0.007

<0.008 12/28/2021 0.019 0.020 0.016 0.017 0.023 0.015 (1) Station with highest annual mean.

Annual Radiological Environmental Operating Report Plant: Turkey Point Nuclear Units 3 & 4 Units: pCi/m3 Analysis: Gross Beta Monitoring Results Tables Table8: Air Particulate - Gross Beta Page 1 of 16

Page 34 of 55 Location Collection Date Be-7 K-40 Cs-134 Cs-137 Pb-210 0.05 0.06 T41 (Indicator) 03/31/2021 0.1680

<0.0173

<0.0011

<0.0009 0.0097 T51 (Indicator) 03/31/2021 0.1460

<0.0131

<0.0012

<0.0009

<0.0083 T57 (Indicator) 03/31/2021 0.1440

<0.0142

<0.0013

<0.0009

<0.0151 T58 (Indicator) 03/31/2021 0.1270

<0.0180

<0.0009

<0.0007 0.0068 T64 (Control) 03/31/2021 0.1620

<0.0124

<0.0011

<0.0009 0.0106 T72 (Indicator) 03/31/2021 0.1610

<0.0223

<0.0010

<0.0008 0.0137 T41 (Indicator) 06/30/2021 0.1060

<0.0165

<0.0009

<0.0008 0.0110 T51 (Indicator) 06/30/2021 0.1230

<0.0162

<0.0014

<0.0010

<0.0148 T57 (Indicator) 06/30/2021 0.1430

<0.0169

<0.0012

<0.0010 0.0123 T58 (Indicator) 06/30/2021 0.1550

<0.0147

<0.0010

<0.0009 0.0127 T64 (Control) 06/30/2021 0.1120

<0.0147

<0.0010

<0.0007 0.0069 T72 (Indicator) 06/30/2021 0.1530

<0.0144

<0.0012

<0.0009

<0.0147 T41 (Indicator) 09/30/2021 0.1000

<0.0118

<0.0010

<0.0008 0.0085 T51 (Indicator) 09/30/2021 0.0971

<0.0138

<0.0009

<0.0008 0.0105 T57 (Indicator) 09/30/2021 0.0892

<0.0147

<0.0009

<0.0008 0.0101 T58 (Indicator) 09/30/2021 0.1070

<0.0128

<0.0013

<0.0011

<0.0154 T64 (Control) 09/30/2021 0.0843

<0.0150

<0.0008

<0.0007 0.0134 T72 (Indicator) 09/30/2021 0.0830

<0.0178

<0.0008

<0.0007 0.0136 T41 (Indicator) 12/28/2021 0.0825

<0.0120

<0.0010

<0.0008

<0.0115 T51 (Indicator) 12/28/2021 0.0818

<0.0132

<0.0007

<0.0007 0.009 T57 (Indicator) 12/28/2021 0.0802

<0.0132

<0.0010

<0.0007

<0.0118 T58 (Indicator) 12/28/2021 0.0901

<0.0131

<0.0007

<0.0006 0.0072 T64 (Control) 12/28/2021 0.0996

<0.0108

<0.0009

<0.0007

<0.0113 T72 (Indicator) 12/28/2021 0.0902

<0.0138

<0.0007

<0.0006

<0.0075 Annual Radiological Environmental Operating Report Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 REQUIRED LLD Table9: Air Particulate Composite - Gamma Monitoring Results Tables Analysis: Gamma Isotopic Units: pCi/m3 Page 2 of 16

Year: 2021 Page 35 of 55 End Date T41 (Indicator)

T51 (Indicator)

T57 (Indicator)

T58 (Indicator)

T64 (Control)

T72 (Indicator)

LLD 0.07 0.07 0.07 0.07 0.07 0.07 01/06/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.07 01/14/2021

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01 01/20/2021

<0.01

<0.01

<0.01

<0.01

<0.01

<0.11 01/25/2021

<0.03

<0.03

<0.03

<0.03

<0.03

<0.04 02/02/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 02/09/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 02/17/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 02/25/2021

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01 03/02/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 03/08/2021

<0.03

<0.03

<0.03

<0.03

<0.03

<0.03 03/16/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 03/25/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 03/31/2021

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01 04/06/2021

<0.03

<0.03

<0.03

<0.03

<0.03

<0.03 04/14/2021

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01 04/22/2021

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01 04/29/2021

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01 05/05/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 05/12/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 05/20/2021

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01 05/26/2021

<0.02

<0.03

<0.02

<0.02

<0.02

<0.02 06/02/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 06/09/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 06/16/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 06/24/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 06/30/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 07/08/2021

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01 07/13/2021

<0.03

<0.03

<0.03

<0.03

<0.03

<0.03 07/21/2021

<0.02

<0.02

<0.02

<0.01

<0.01

<0.02 07/29/2021

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01 08/04/2021

<0.04

<0.04

<0.04

<0.04

<0.04

<0.04 08/11/2021

<0.03

<0.03

<0.03

<0.03

<0.03

<0.03 08/18/2021

<0.02

<0.02

<0.02

<0.03

<0.02

<0.02 08/24/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 08/31/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 09/09/2021

<0.01

<0.01

<0.01

<0.01

<0.01

<0.01 09/14/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 09/21/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 09/30/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 10/06/2021

<0.03

<0.03

<0.03

<0.03

<0.03

<0.03 10/12/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 10/20/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 10/25/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 11/02/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 11/10/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 11/17/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 11/24/2021

<0.03

<0.03

<0.02

<0.02

<0.03

<0.03 12/01/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 12/08/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 12/16/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 12/21/2021

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02 12/28/2021

<0.02

<0.03

<0.03

<0.02

<0.03

<0.03 Analysis: Gross Beta Units: pCi/m3 Plant: Turkey Point Nuclear Units 3 & 4 Annual Radiological Environmental Operating Report Page 3 of 16 Monitoring Results Tables Table10: Air Cartridges - Iodine-131

Page 36 of 55 Station 1st Qtr 2021 2nd Qtr 2021 3rd Qtr 2021 4th Qtr 2021 Annual Mean 2021 N-2 4.9 4.6 4.1 4.2 4.5 N-7 3.9 3.4 3.1 3.6 3.5 N-10 4.5 3.9 3.4 3.8 3.9 NNW-2 4.2 3.8 3.9 3.4 3.8 NNW-10 4.3 4.1 3.7 3.8 4.0 NW-1 4.9 4.4 4.3 4.1 4.4 NW-5 3.9 3.6 3.4 3.5 3.6 NW-10(1) 5.1 4.8 4.1 4.5 4.6 WNW-2 4.1 3.9 3.7 3.7 3.8 WNW-10 4.9 4.5 4.2 4.2 4.4 W-1 4.6 4.4 3.8 4.0 4.2 W-5 4.2 3.9 3.7 3.9 3.9 W-9 3.9 3.7 3.1 3.4 3.5 WSW-8 4.1 3.7 3.5 3.6 3.7 SW-1 4.5 4.0 4.0 4.0 4.1 SW-8 3.5 3.1 3.0 2.9 3.1 SSW-5 3.7 3.4 3.0 3.3 3.4 SSW-10 3.8 3.5 3.5 3.3 3.5 S-5 3.4 3.2 2.7 3.2 3.1 S-10 4.1 3.8 3.8 3.7 3.9 SSE-1 3.2 3.3 3.0 3.0 3.1 SSE-10 3.6 3.4 2.8 3.4 3.3 (1) Indicator station with highest annual mean.

Station 1st Qtr 2021 2nd Qtr 2021 3rd Qtr 2021 4th Qtr 2021 Annual Mean 2021 NNE-22 4.4 4.0 3.7 4.3

4.1 Table12

Direct Radiation - Control Analysis: Gamma Dose Units: mrem/Hr Table11: Direct Radiation-Indicators Analysis: Gamma Dose Units: mrem/hr Year: 2021 Annual Radiological Environmental Operating Report Monitoring Results Tables Plant: Turkey Point Nuclear Units 3 & 4 Page 4 of 16

Location End Date H-3 K-40 Location End Date H-3 K-40 Location End Date H-3 K-40 3,000 3,000 3,000 T42 (Indicator) 01/22/2021

<137 275 T67 (Control) 01/26/2021

<133 102 T81 (Indicator) 01/22/2021

<133 280 T42 (Indicator) 02/04/2021

<137 249 T67 (Control) 02/05/2021

<137 270 T81 (Indicator) 02/05/2021

<137 243 T42 (Indicator) 03/11/2021

<133 248 T67 (Control) 03/15/2021

<138 245 T81 (Indicator) 03/09/2021

<139 337 T42 (Indicator) 04/07/2021

<134 181 T67 (Control) 04/06/2021

<134

<47 T81 (Indicator) 04/07/2021

<134 372 T42 (Indicator) 05/11/2021 118 326 T67 (Control) 05/10/2021 118 262 T81 (Indicator) 05/11/2021

<140 409 T42 (Indicator) 06/15/2021

<134 394 T67 (Control) 06/16/2021

<134 348 T81 (Indicator) 06/15/2021

<134 337 T42 (Indicator) 07/12/2021

<141 377 T67 (Control) 07/12/2021

<142 218 T81 (Indicator) 07/09/2021

<141 377 T42 (Indicator) 08/10/2021

<137 342 T67 (Control) 08/11/2021

<135 225 T81 (Indicator) 08/10/2021

<137 372 T42 (Indicator) 09/20/2021 72 316 T67 (Control) 09/21/2021

<134

<49 T81 (Indicator) 09/17/2021

<134 374 T42 (Indicator) 10/11/2021

<136 234 T67 (Control) 10/11/2021

<136 264 T81 (Indicator) 10/11/2021

<136 330 T42 (Indicator) 11/03/2021

<135 252 T67 (Control) 11/04/2021

<135 219 T81 (Indicator) 11/03/2021 105 279 T42 (Indicator) 12/27/2021

<132 203 T67 (Control) 12/28/2021

<132 270 T81 (Indicator) 12/27/2021 92 211 REQUIRED LLD REQUIRED LLD REQUIRED LLD Units: pCi/L Analysis: Gamma Isotopic Table13: Surface Water - Tritium and Gamma Page 5 of 16 Page 37 of 55 Year: 2021 Plant: Turkey Point Nuclear Units 3 & 4 Annual Radiological Environmental Operating Report Monitoring Results Tables

Location Collection Date Be-7 K-40 Cs-137 Pb-210 Ra-226 Th-232 U-235 U-238 180 T42 (Indicator) 02/04/2021

<80

<128

<8

<344

<207

<37

<13 118 T67 (Control) 02/05/2021

<63 88

<7

<305

<182

<34

<11 87 T81 (Indicator) 02/05/2021

<91 135

<9 515 543

<41 34 278 T42 (Indicator) 07/12/2021

<134

<98

<8

<330 593

<30 37 151 T67 (Control) 07/12/2021

<101 130

<9

<242 181

<64 11 94 T81 (Indicator) 07/09/2021

<156

<130

<10 316 974

<39 61 495 REQUIRED LLD Page 38 of 55 Year: 2021 Plant: Turkey Point Nuclear Units 3 & 4 Table14: Shoreline Sediment - Gamma Units: pCi/kg (dry)

Analysis: Gamma Isotopic Annual Radiological Environmental Operating Report Monitoring Results Tables Page 6 of 16

Year: 2021 Location Collection Date Sample Type K-40 Ra-226 Ra-228 T67 (Control) 06/22/2021 Blue Crab 1500

<429

<76 T81 (Indicator) 03/11/2021 Blue Crab 1360

<555

<98 T67 (Control) 12/20/2021 Blue Crab 1380

<439

<117 T81 (Indicator) 12/21/2021 Blue Crab 1400 495

<91 REQUIRED LLD Table15: Crustacea - Gamma Monitoring Results Tables Units: pCi/kg (wet)

Analysis: Gamma Isotopic Annual Radiological Environmental Operating Report Plant: Turkey Point Nuclear Units 3 & 4 Page 39 of 55 Page 7 of 16

Year: 2021 Location Collection Date Sample Type K-40 Ra-226 Ra-228 T67 (Control) 06/21/2021 Mixed Species 2160

<342

<74 T81 (Indicator) 05/11/2021 Mixed Species 1990

<476

<70 T67 (Control) 12/20/2021 Mixed Species 3290

<1170

<243 T81 (Indicator) 12/20/2021 Mixed Species 3130

<396

<103 Monitoring Results Tables Table16: Fish - Gamma Analysis: Gamma Isotopic Units: pCi/kg (wet)

REQUIRED LLD Plant: Turkey Point Nuclear Units 3 & 4 Page 40 of 55 Annual Radiological Environmental Operating Report Page 8 of 16

Location Collection Date Sample Type Be-7 K-40 Cs-137 Pb-210 Pb-212 Ra-226 80 T40 (Indicator) 01/25/2021 Brazilian Pepper 2090 4750

<12

<113

<20

<245 T40 (Indicator) 02/09/2021 Brazilian Pepper 1650 3870 35

<110

<19

<232 T40 (Indicator) 03/09/2021 Brazilian Pepper 1020 3070 18

<580

<16

<212 T40 (Indicator) 04/07/2021 Brazilian Pepper 949 2770 39

<594

<18

<196 T40 (Indicator) 05/12/2021 Brazilian Pepper 651 3070 41

<527

<15

<177 T40 (Indicator) 06/15/2021 Brazilian Pepper 1170 2820 54

<467

<14

<166 T40 (Indicator) 07/12/2021 Brazilian Pepper 1340 2850 26

<228

<17

<201 T40 (Indicator) 08/10/2021 Brazilian Pepper 2010 4430 29 80

<15

<199 T40 (Indicator) 09/21/2021 Brazilian Pepper 1620 2820 45

<207

<16

<193 T40 (Indicator) 10/11/2021 Brazilian Pepper 1760 3130 45 62

<15

<191 T40 (Indicator) 11/03/2021 Brazilian Pepper 2440 3150 49 332

<16

<203 T40 (Indicator) 12/29/2021 Brazilian Pepper 1280 3360 38

<218

<15

<189 T41(Indicator) 01/25/2021 Brazilian Pepper 1410 5180

<13

<297

<21

<258 T41(Indicator) 02/09/2021 Brazilian Pepper 1010 4730

<10 171

<21

<236 T41(Indicator) 03/09/2021 Brazilian Pepper 1320 4770

<10 87

<18

<136 T41(Indicator) 04/07/2021 Brazilian Pepper 1630 2580 57 336

<18

<190 T41(Indicator) 05/12/2021 Brazilian Pepper 582 4460 11

<183

<15

<159 T41(Indicator) 06/15/2021 Brazilian Pepper 630 4930

<8

<513

<14

<175 T41(Indicator) 07/12/2021 Brazilian Pepper 1180 5360

<10

<594

<16

<198 T41(Indicator) 08/10/2021 Brazilian Pepper 1700 4640 8

<247

<19

<216 T41(Indicator) 09/21/2021 Brazilian Pepper 2340 5000

<12

<92

<16

<206 T41(Indicator) 10/11/2021 Brazilian Pepper 1350 4730

<9 192

<15

<188 T41(Indicator) 11/03/2021 Brazilian Pepper 1520 3270

<10

<230

<17

<204 T41(Indicator) 12/29/2021 Brazilian Pepper 2010 5510 4

521

<17

<197 T67 (Control) 01/26/2021 Brazilian Pepper 1130 4300 8

<231

<17

<193 T67 (Control) 02/09/2021 Brazilian Pepper 771 4950 13

<88

<16

<180 T67 (Control) 03/17/2021 Brazilian Pepper 1030 4240 5

<590 16

<211 T67 (Control) 04/07/2021 Brazilian Pepper 728 3990

<10

<214

<17

<182 T67 (Control) 05/10/2021 Brazilian Pepper 1320 3690

<8 44 5

<154 T67 (Control) 06/16/2021 Brazilian Pepper 1470 2400

<9

<77

<14

<158 T67 (Control) 07/13/2021 Brazilian Pepper 1740 2750 6

<556

<15

<179 T67 (Control) 08/11/2021 Brazilian Pepper 1780 3660 11 45

<15

<185 T67 (Control) 09/21/2021 Brazilian Pepper 2220 3250 14 231

<16

<179 T67 (Control) 10/11/2021 Brazilian Pepper 2510 2860 13

<86

<15

<182 T67 (Control) 11/04/2021 Brazilian Pepper 1320 3930 13 164

<19

<215 T67 (Control) 12/28/2021 Brazilian Pepper 1260 3910

<12 404

<20

<235 REQUIRED LLD Table17: Broad Leaf Vegetation - Gamma Analysis: Gamma Isotopic Units: pCi/kg (wet)

Monitoring Results Tables Annual Radiological Environmental Operating Report Page 41 of 55 Year: 2021 Plant: Turkey Point Nuclear Units 3 & 4 Page 9 of 16

Page 42 of 55 Station 1st Qtr 2021 2nd Qtr 2021 3rd Qtr 2021 4th Qtr 2021 Annual Mean 2021 NNW-6 4.4 3.8 3.8 3.8 3.9 NW-7(1) 4.9 4.6 4.0 4.1 4.4 NW-8 4.7 4.3 4.3 4.1 4.4 WNW-3 4.3 3.6 3.4 3.7 3.7 WNW-6 4.3 3.6 3.6 3.6 3.8 W-8 4.4 3.9 3.7 3.8 3.9 ENE-1 3.4 3.0 3.0 3.0 3.1 T72 4.0 3.9 3.6 3.8 3.8 PTN-1 4.2 3.9 3.4 3.7 3.8 (1) Indicator station with highest annual mean.

Table18: Supplemental Direct Radiation-Indicators Analysis: Gamma Dose Units: mrem/hr Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Annual Radiological Environmental Operating Report Page 10 of 16 Monitoring Results Tables

Page 43 of 55 Page 11 of 16 End Date LLD 01/06/2021 01/14/2021 01/20/2021 01/25/2021 02/02/2021 02/09/2021 02/17/2021 02/25/2021 03/02/2021 03/08/2021 03/16/2021 03/25/2021 03/31/2021 04/06/2021 04/14/2021 04/22/2021 04/29/2021 05/05/2021 05/12/2021 05/20/2021 05/26/2021 06/02/2021 06/09/2021 06/16/2021 06/24/2021 06/30/2021 07/08/2021 07/13/2021 07/21/2021 07/29/2021 08/04/2021 08/11/2021 08/18/2021 08/24/2021 08/31/2021 09/09/2021 09/14/2021 09/21/2021 09/30/2021 10/06/2021 10/12/2021 10/20/2021 10/26/2021 11/02/2021 11/10/2021 11/17/2021 11/24/2021 12/01/2021 12/08/2021 12/16/2021 12/21/2021 12/28/2021 (1) Station with highest annual mean.

0.006 0.015 0.012 0.009 0.026 0.014 0.012 0.017 0.019 0.013 0.015 0.010 0.020 0.019 0.005 0.010 0.020 0.013 0.007 0.010 0.020 0.019 0.012 0.023 0.013 0.014 0.019 0.016 0.008 0.010 0.013 0.018 0.009 0.010 0.017 0.013 0.007 0.020 0.023 0.013 0.013 0.010 0.008 0.020 T56(1) (Indicator) 0.01 0.016 0.019 0.019 0.016 0.014 0.014 0.003 0.012 0.004 0.008 0.013 0.011 0.017 0.007 0.019 0.011 0.022 0.022 0.022 0.011 0.023 0.013 0.019 0.027 0.006 0.010 0.013 0.012 0.004 0.011 0.006 0.020 0.008 0.010 0.019 0.010 0.010 0.015 0.016 0.008 0.018 T52 (Indicator) 0.01 0.012 0.018 0.019 0.019 0.014 0.009 0.003 0.006 0.008 0.010 0.018 0.009 0.006 0.016 0.022 Analysis: Gross Beta Table19: Supplemental Air Particulate - Gross Beta Monitoring Results Tables Annual Radiological Environmental Operating Report Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Units: pCi/m3 0.020 0.020 0.023 0.019

Page 44 of 55 Location Collection Date Be-7 K-40 Cs-134 Cs-137 Pb-210 0.05 0.06 T52 (Indicator) 03/31/2021 0.1320

<0.0192

<0.0009

<0.0007 0.0108 T56 (Indicator) 03/31/2021 0.1470

<0.0159

<0.0011

<0.0007 0.0127 T52 (Indicator) 06/30/2021 0.1350

<0.0152

<0.0010

<0.0009

<0.0115 T56 (Indicator) 06/30/2021 0.1210

<0.0142

<0.0009

<0.0009 0.0145 T52 (Indicator) 09/30/2021 0.1080

<0.0174

<0.0014

<0.0009

<0.0156 T56 (Indicator) 09/30/2021 0.0935

<0.0146

<0.0009

<0.0008 0.008 T52 (Indicator) 12/28/2021 0.1010

<0.0086

<0.0009

<0.0006 0.0146 T56 (Indicator) 12/28/2021 0.0924

<0.0137

<0.0008

<0.0006 0.0103 Table20: Supplemental Air Particulate Composite - Gamma Analysis: Gamma Isotopic Units: pCi/m3 REQUIRED LLD Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Annual Radiological Environmental Operating Report Page 12 of 16 Monitoring Results Tables

Page 45 of 55 Page 13 of 16 End Date LLD 01/06/2021 01/14/2021 01/20/2021 01/25/2021 02/02/2021 02/09/2021 02/17/2021 02/25/2021 03/02/2021 03/08/2021 03/16/2021 03/25/2021 03/31/2021 04/06/2021 04/14/2021 04/22/2021 04/29/2021 05/05/2021 05/12/2021 05/20/2021 05/26/2021 06/02/2021 06/09/2021 06/16/2021 06/24/2021 06/30/2021 07/08/2021 07/13/2021 07/21/2021 07/29/2021 08/04/2021 08/11/2021 08/18/2021 08/24/2021 08/31/2021 09/09/2021 09/14/2021 09/21/2021 09/30/2021 10/06/2021 10/12/2021 10/20/2021 10/26/2021 11/02/2021 11/10/2021 11/17/2021 11/24/2021 12/01/2021 12/08/2021 12/16/2021 12/21/2021 12/28/2021

<0.02

<0.03

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02

<0.02

<0.01

<0.02

<0.02

<0.02

<0.03

<0.04

<0.03

<0.02

<0.02

<0.02

<0.02

<0.01

<0.03

<0.02

<0.01

<0.02

<0.02

<0.02

<0.02

<0.02

<0.01

<0.01

<0.02

<0.02

<0.01

<0.02

<0.02

<0.01

<0.03

<0.01

<0.02

<0.02

<0.02

<0.02 T56 (Indicator) 0.07

<0.02

<0.01

<0.01

<0.03

<0.02

<0.02

<0.02

<0.01

<0.02

<0.03

<0.02

<0.02

<0.02

<0.03

<0.02

<0.02

<0.03

<0.02

<0.02

<0.02

<0.02

<0.02

<0.01

<0.02

<0.02

<0.02

<0.01

<0.04

<0.03

<0.02

<0.02

<0.02

<0.02

<0.01

<0.03

<0.02

<0.01

<0.02

<0.02

<0.02

<0.01

<0.01

<0.01

<0.02

<0.02

<0.03

<0.02

<0.02

<0.01

<0.02

<0.02

<0.01 T52 (Indicator) 0.07

<0.02

<0.01

<0.01

<0.03 Plant: Turkey Point Nuclear Units 3 & 4 Annual Radiological Environmental Operating Report Monitoring Results Tables Table21: Supplemental Air Cartridges - Iodine-131 Analysis: Gross Beta Units: pCi/m3 Year: 2021

<0.03

<0.02

Location End Date H-3 K-40 Location End Date H-3 K-40 Location End Date H-3 K-40 Location End Date H-3 K-40 3,000 3,000 3,000 3,000 T08 (Indicator) 01/22/2021 3734 289 T75 (Indicator) 01/25/2021 <133

<42 T84 (Indicator) 01/22/2021 4084 378 T97 (Indicator) 01/22/2021 4107 325 T08 (Indicator) 02/05/2021 4720 377 T75 (Indicator) 02/05/2021 <137

<40 T84 (Indicator) 02/05/2021 3262 313 T97 (Indicator) 02/04/2021 3465 339 T08 (Indicator) 03/09/2021 7204 288 T75 (Indicator) 03/09/2021 <139

<80 T84 (Indicator) 03/09/2021 5349 251 T97 (Indicator) 03/11/2021 7460 336 T08 (Indicator) 04/07/2021 5817 446 T75 (Indicator) 04/07/2021 <134

<77 T84 (Indicator) 04/07/2021 5380 457 T97 (Indicator) 04/07/2021 5454 441 T08 (Indicator) 05/11/2021 10578 443 T75 (Indicator) 05/11/2021 <135

<34 T84 (Indicator) 05/11/2021 11455 463 T97 (Indicator) 05/11/2021 12658 433 T08 (Indicator) 06/15/2021 5669 413 T75 (Indicator) 06/15/2021 <134

<49 T84 (Indicator) 06/15/2021 6051 397 T97 (Indicator) 06/15/2021 6074 466 T08 (Indicator) 07/09/2021 4153 399 T75 (Indicator) 07/12/2021 <141

<47 T84 (Indicator) 07/09/2021 4307 355 T97 (Indicator) 07/12/2021 3985 369 T08 (Indicator) 08/10/2021 4937 388 T75 (Indicator) 08/10/2021 <137

<79 T84 (Indicator) 08/10/2021 3247 383 T97 (Indicator) 08/10/2021 3201 470 T08 (Indicator) 09/20/2021 9978 351 T75 (Indicator) 09/21/2021 <134

<37 T84 (Indicator) 09/20/2021 9648 382 T97 (Indicator) 09/20/2021 9959 379 T08 (Indicator) 10/11/2021 8666 286 T75 (Indicator) 10/11/2021 <136

<76 T84 (Indicator) 10/11/2021 13471 363 T97 (Indicator) 10/11/2021 13492 365 T08 (Indicator) 11/03/2021 12214 341 T75 (Indicator) 11/03/2021 <135 87 T84 (Indicator) 11/03/2021 11692 415 T97 (Indicator) 11/03/2021 12474 339 T08 (Indicator) 12/27/2021 9618 280 T75 (Indicator) 12/27/2021 <132

<78 T84 (Indicator) 12/29/2021 9291 326 T97 (Indicator) 12/27/2021 9242 316 Monitoring Results Tables Page 14 of 16 Annual Radiological Environmental Operating Report Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 46 of 55 REQUIRED LLD Analysis: Gamma Isotopic Units: pCi/L Table22: Supplemental Surface Water - Tritium and Gamma REQUIRED LLD REQUIRED LLD REQUIRED LLD

Location Collection Date Be-7 K-40 Cs-137 Pb-210 Ra-226 Th-232 U-235 U-238 180 T01 (Indicator) 02/04/2021

<131

<163

<9 915 464

<48 29 230 T02 (Indicator) 02/05/2021

<194 2410 19 2150

<621

<108 181 966 T03 (Indicator) 02/05/2021

<374 3200 84 6690

<962

<154 299 1450 T04 (Indicator) 02/05/2021

<134 327

<11 789 547

<49 35 226 T07 (Indicator) 02/05/2021

<175 289 45

<687 326

<60

<30

<203 T08 (Indicator) 02/05/2021

<143 531

<13 566 776

<83

<28

<217 T10 (Indicator) 02/05/2021

<159 546

<15

<714 539

<60

<27

<210 T84* (Indicator) 02/09/2021

<189 399

<14 2540 1670

<70 105 245 T85* (Indicator) 02/05/2021

<102 100

<10 495 698

<51 44 242 T84* (Indicator) 07/09/2021

<272 222

<18 2030 2690

<72 170 311 T85* (Indicator) 07/09/2021

<187 636

<14

<602 1230

<86 77 299

  • Note that site T48 is the same location as site T05, and site T85 is the same location as site T06.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 47 of 55 Annual Radiological Environmental Operating Report Page 15 of 16 Monitoring Results Tables Table23: Supplemental Shoreline Sediment - Gamma Analysis: Gamma Isotopic Units: pCi/kg (dry)

REQUIRED LLD

Location Collection Date Sample Type Be-7 K-40 Cs-137 Ra-226 80 T43 (Indicator) 02/08/2021 Corn & Green Beans

<90 2080

<12

<233 T44 (Indicator) 03/08/2021 Corn & Green Beans

<55 2250

<7

<169 T45 (Indicator) 03/22/2021 Corn & Green Beans

<81 1900

<10

<209 Page 48 of 55 Year: 2021 Plant: Turkey Point Nuclear Units 3 & 4 Annual Radiological Environmental Operating Report Page 16 of 16 Analysis: Gamma Isotopic REQUIRED LLD Monitoring Results Tables Table24: Supplemental Broad Leaf Vegetation - Gamma Units: pCi/kg (wet)

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 49 of 55 Annual Radiological Environmental Operating Report Page 1 of 3 Interlaboratory Comparison Program Results 1.0 Summary The Interlaboratory Comparison Program consists of participating in the DOE Mixed Analyte Performance Evaluation Program (MAPEP).

This program provides similar testing (matrices, nuclides, and levels) as the former EPA Interlaboratory Comparison Program and is referred to as the Mixed Analyte Performance Evaluation Program (MAPEP).

The samples are analyzed using the methods applicable to the REMP (gamma spectroscopy, Gross Beta, and Tritium for water).

From the MAPEP handbook:

Acceptance criteria were developed from a review of precision and accuracy data compiled by other performance evaluation programs (PEPs), the analytical methods literature, from several MAPEP pilot studies, and from what is considered reasonable, acceptable, and achievable for routine analyses among the more experienced laboratories.

The State laboratory participated in MAPEP 44 and 45. These satisfied the requirement of Control 5.3 of the ODCM for the Interlaboratory Comparison Program.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 50 of 55 Annual Radiological Environmental Operating Report Page 2 of 3 Interlaboratory Comparison Program Results Table 25: DOEs Mixed Analyte Performance Evaluation Program (MAPEP) 44 RESULTS Program status Radionuclide Result Ref.

Value Flag (Evaluation)

Acceptance Range Matrix: RdF Air Filter Bq/filter Required MN54 0.3 0.312 A

0.218 - 0.406 Required CO57 0.62 0.686 A

0.480 - 0.892 Required CO60 0.018 A

False Positive Test ZN65 0.358 0.352 A

0.246 - 0.458 Required CS134 1.841 2.14 A

1.50 - 2.78 Required CS137 0.004 A

False Positive Test Matrix: GrF Air Filter Bq/filter Required Gross Beta 0.7915 0.649 A

0.325 - 0.974 Required Gross Alpha 2.01 1.77 A

0.53 - 3.01 Matrix: MaS Soil Bq/kg Required K40 620.25 618 A

433 - 803 MN54 0.70 A

False Positive Test CO57 838.63 920 A

644 - 1196 CO60 1320 1370 A

959 - 1781 ZN65 630.88 604 A

423 - 785 CS134 0.12 A

False Positive Test Required CS137 1541.25 1550 A

1085 - 2015 Matrix: MaW Water Bq/L Required H3 1.098 A

False Positive Test MN54 16.2 15.5 A

10.9 - 20.2 CO57 11.7 11.4 A

8.0 - 14.8 Required CO60 0.1 A

False Positive Test ZN65 11.5 10.5 A

7.4 - 13.7 Required CS134 10.908 11.5 A

8.1 - 15.0 Required CS137 8.27 7.9 A

5.5 - 10.3 SR90 4.003 4.47 A

3.13 - 5.81 Matrix: RdV Vegetation, Bq/sample MN54 5.956 5.25 A

3.68 - 6.83 CO57 6.197 5.05 W

3.54 - 6.57 Required CO60 3.213 2.99 A

2.09 - 3.89 ZN65 0.005 A

False Positive Test CS134 3.861 3.6 A

2.5 - 4.7 Required CS137 5.409 4.69 A

3.28 - 6.10 Evaluation: A = Acceptable, W = Acceptable with Warning, N = Not Acceptable, NR = Not Reported A false positive test with an A designation flag identifies the result as less than the detectable activity, since MAPEP does not report zero values. Sensitivity Evaluation has no acceptance range but an identified value at low activity.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 51 of 55 Annual Radiological Environmental Operating Report Page 3 of 3 Interlaboratory Comparison Program Results Table 26: DOEs Mixed Analyte Performance Evaluation Program (MAPEP) 45 RESULTS Program status Radionuclide Result Ref.

Value Flag (Evaluation)

Acceptance Range Matrix: RdF Air Filter Bq/filter Required MN54 1.540 1.46 A

1.02 - 1.90 Required CO57 0.779 0.83 A

0.58 - 1.08 Required CO60 2.230 2.28 A

1.60 - 2.96 ZN65 0.014 A

False Positive Test Required CS134 1.202 1.32 A

0.92 - 1.72 Required CS137 1.305 1.28 A

0.90 - 1.66 Matrix: GrF Air Filter Bq/filter Required Gross Beta 0.66 0.553 A

0.277 - 0.830 Required Gross Alpha 1.247 0.960 A

0.288 - 1.632 Matrix: MaS Soil Bq/kg Required K40 578.61 607 A

425 - 789 MN54 404.87 410 A

287 - 533 CO57 1.22 A

False Positive Test CO60 679.30 722 A

505 - 939 ZN65 913.99 907 A

635 - 1179 CS134 1152.05 1170 A

819 - 1521 Required CS137 553.85 572 A

400 - 744 Matrix: MaW Water Bq/L Required H3 266.45 250 A

175 - 325 MN54 9.053 9.0 A

6.3 - 11.7 CO57 13.117 13.9 A

9.7 - 18.1 Required CO60 13.450 14.0 A

9.8 - 18.2 ZN65 0.277 A

False Positive Test Required CS134 9.349 10.4 A

7.3 - 13.5 Required CS137

-0.010 A

False Positive Test SR90 3.552 3.86 A

2.70 - 5.02 Matrix: RdV Vegetation, Bq/sample:

MN54

-0.003 A

False Positive Test CO57 5.169 4.66 A

3.26 - 6.06 Required CO60 3.610 3.51 A

2.46 - 4.56 ZN65 2.604 2.43 A

1.70 - 3.16 CS134 4.189 4.34 A

3.04 - 5.64 Required CS137 2.380 2.21 A

1.55 - 2.87 Evaluation: A = Acceptable, W = Acceptable with Warning, N = Not Acceptable, NR = Not Reported A false positive test with an A designation flag identifies the result as less than the detectable activity, since MAPEP does not report zero values. Sensitivity Evaluation has no acceptance range but an identified value at low activity.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 52 of 55 Annual Radiological Environmental Operating Report Page 1 of 4 Industry Initiative Ground Water Protection Program 2021 1.0 Description of Program Turkey Point Nuclear maintains a sampling and analysis program to meet procedural requirements.

The procedures that govern the performance are EV-AA-100-1001, Fleet Ground Water Protection Program Implementing Guideline and 0-ADM-654, Ground Water Protection Program.

The sampling frequency is quarterly; more often if conditions warrant.

Sample assay is performed by a private contractor GEL labs.

2.0 Discussion The Turkey Point Nuclear site is surrounded on three sides by the closed cooling canal system.

This canal system, in addition to being the source of tertiary cooling, is the body of water receiving permitted liquid radiological waste the canal system tritium level averages was 7,126 pCi/L in 2021 with a max concentration of 13,492 pCi/L. This supports the expectation to see tritium in subsurface water collected either on-site or off-site close to the (within the Owner Controlled Area) cooling canal system. Twenty-eight (28) wells were involved in the 2021 monitoring program; some locations have multiple (two or three) depths.

Samples are analyzed for Tritium & Gamma emitters. As conditions warrant, analysis included Fe-55, Ni-63, Sr-89/90 and alpha (all were < LLD).

3.0 Results The tritium results for the groundwater wells were from <MDA to 5,320 pCi/L. All results were less than the limits of the Offsite Dose Calculation Manual, Table 5.1-2, Reporting Levels for Radioactivity Concentrations in Environmental Samples. Storm drain outfalls occasionally are below the tidal mark of the canal and will have ingress of canal water into the storm drain. The higher levels of tritium in the storm drain section are due to the canal water ingress into the storm drain.

Tabular results follow:

Year: 2021 Page 53 of 55 Location First Quarter 2021 H-3 Second Quarter 2021 H-3 Third Quarter 2021 H-3 Fourth Quarter 2021 H-3 REQUIRED LLD 3,000 3,000 3,000 3,000 PTPED-1 146 364 336 271 CD-1 255 122 288 92.7 P-94-2 517 519 P-94-4 471 706 386 623 STP-1 88 22.7 PTN-MW-1s

-45 146 PTN-MW-1i 365 283 PTN-MW-1d 1210 1420 PTN-MW-2s 87 115 PTN-MW-3s 160

-10.3 PTN-MW-4s

-45 152 2550 77 PTN-MW-4i 1490 1900 223 76.2 PTN-MW-4d 127 152

-46.5

-11.2 PTN-MW-5s 579 218 94.9 5.82 PTN-MW-5i 453 267 268 105 PTN-MW-5d 1540 1490 79.9 1480 PTN-MW-6s 20 55.1 PTN-MW-6i PTN-MW-6d 1220 1360 PTN-MW-7s 742 1160 787 447 PTN-MW-7i 133 14 1300 31.2 PTN-MW-7d 29 116 42.3 202 PTN-MW-8s 5320 355 1290 820 PTN-MW-9s 859 1110 739 984 PTN-MW-10s 78 56.3 PTN-MW-10i 765 44.6 PTN-MW-10d 98 98.9 PTN-MW-11s 7

314 319 544 PTN-MW-12s 545 623 761 686 NE StrmDrain 869 626 647 21.3 SE StrmDrain 620 482 340 573 W StrmDrain 536 4420 2830 1720 CRF StrmDrain dry dry dry dry Monitoring Results Tables Annual Radiological Environmental Operating Report Page 2 of 4 Plant: Turkey Point Nuclear Units 3 & 4 Table27: Ground Water - Tritium Analysis: Tritium Units: pCi/L

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 54 of 55 Annual Radiological Environmental Operating Report Page 3 of 4 Industry Initiative Ground Water Protection Program 2021 D. List of wells and their locations Well Name Location PTN-MW-1s PTN-MW-1i PTN-MW-1d Northeast of Switch Yard, South of entrance road to Fossil Plant PTN-MW-2s South Switch Yard by parking lot PTN-MW-3s Northeast of new Issues Warehouse PTN-MW-4s PTN-MW-4i PTN-MW-4d SW corner of parking lot South of Training Bldg.

PTN-MW-5s PTN-MW-5i PTN-MW-5d SW of CRF, by canal PTN-MW-6s PTN-MW-6d NE of site in the berm for fossil oil tanks PTN-MW-7s PTN-MW-7i PTN-MW-7d NE of RCA, by Neutralization Tank PTN-MW-8s Near U3 RWST PTN-MW-9s Near U4 RWST PTN-MW-10s PTN-MW-10i PTN-MW-10d SE of Radwaste Bldg. by S/G Bldg.

PTN-MW-11s South of truck entrance to Rad Waste Bldg.

PTN-MW-12s West of Condenser Polisher road STP-1 West of Maintenance Bldg. on corner or road into parking lot P-94-4 East of Dressout Building, under delay fence P-94-2 By Neutralization Basin, East of the RCA CD-1 By Neutralization Basin, East of the RCA PTPED-1 By Neutralization Basin, East of the RCA Note: s, i and d refer to well depth: shallow - 20 ft., intermediate - 40 ft. and deep - 60 ft Maps depicting the well locations follow.

Plant: Turkey Point Nuclear Units 3 & 4 Year: 2021 Page 55 of 55 Annual Radiological Environmental Operating Report Page 4 of 4 Industry Initiative Ground Water Protection Program 2021 Figure 5: Onsite Tritium Monitoring Wells